6-5. USE OF INDICATOR LIGHTS FOR TROUBLE SHOOTING Gas Indicator On Off Light I ________ Gas flows: System normal (on.) Gas does not flow Gas flows: Gas does not flow Check gas valve operation. Check gas valve operation and gas line for leaks. System normal (off). Check interface board PC3. On Contactor Indicator Light Off I Contactor closed: System normal (on). Contactor open: Contactor open: Check cords. System interconnecting normal (off). Check interface board PC4. On ~ Wire Feed Indicator ~ Light Off I I I Wire feeds: System normal (on). I Wire does not feed: Wire feeds: Wire does not feed Check circuit breaker CB1 Check System relay CR1. normal (off). Check relay CR1. Check input signal from robot to motor board PC2. should be 0-10 vdc between 1TE and 1TC Signal (common). Check interface board PC4. Check motor board PC2. On WCR Indicator Off Light I I Arc started: System No normal On (on). ~ Interface Control On: Normal. Arc started: arc: Replace weld relay. Replace weld relay. current Power Indicator . No current Light Interface Control On: Check connections between Interface Control and Display Module. arc: System ~ normal (off). Off Interface Control Off: System normal OM-141 438 (off). Page 13