Transcript
2 KNOCK OUT HOLES IN L.H. SIDE USED WHEN L.H. CONNECTIONS ARE REQUIRED POSITION OF LIDS WHEN RAISED FLOW AND RETURN CONNECTIONS GAS CONNECTION L.H. L.H. SIDE VIEW C.I. FLUE PIPE FLOW & RETURN CONNECTIONS FRONT VIEW 2 KNOCK OUT HOLES IN R.H. SIDE USED WHEN R.H. CONNECTIONS ARE REQUIRED GAS CONNECTION R.H.. OVEN DOOR IN OPEN POSITION R.H. SIDE VIEW DESN 510208 PLAN VIEW A B C D E F G H J K L M N mm 987 889 851 679 467 1035 41 1330 756 1125 73 39 3 Models GC and GCB Standard flue P R S 698 499 127 T U 41 W 530 116 GC GCB 5kW 100 or 120 285 N35 20mbar 5kW 120 or 140 285 N35 20mbar NATURAL G20 MAXIMUM HEAT INPUT Thermostat Bypass Main Burner Injector Pilot Injector Inlet Pressure G20 PROPANE G31 5kW (357g/h) 5kW (357g/h) 60 or 80 80 or 100 180 180 L23 L23 37mbar 37mbar 28mbar 28mbar MAXIMUM HEAT INPUT Thermostat Bypass Main Burner Injector Pilot Injector Inlet Pressure Burner Pressure For Natural Gas, the gas valve outlet pressure is non-adjustable, BUT for reference purposes only, a pressure drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance. 2