Download Bosch LBB 1941 Specifications
Transcript
Communications Systems | LBB 1946/00 Plena Six-zone Call Station LBB 1946/00 Plena Six-zone Call Station ▶ Stylish six-zone call station, intended for LBB 1925/10 system pre-amplifier ▶ Unidirectional condenser microphone on flexible stem ▶ Six zone selection keys, all-call key, and momentary PTT-key for calls ▶ Selectable gain, speech filter, and limiter for improved intelligibility ▶ Selectable priority levels and different pre and postcall chimes ▶ LED indications for zone selection, system activity, and call station status The Plena Six-zone Call Station is a stylish, high-quality call station with a stable metal base design, a flexible microphone stem, and a unidirectional condenser microphone. It can make calls to selected zones (one to six and all-call) in a public address system built around the LBB 1925/10 system pre-amplifier. In addition to tabletop use, the special design enables the unit to be neatly flush-mounted in desktops. • • • • • Six zone selection keys Six zone selection LEDs All-call key All-call status LED Eight DIP switches Interconnections • Cable with DIN connector Certifications and Approvals Functions This call station features selectable gain, a selectable speech filter, and a limiter for improved intelligibility. The call station has a balanced line level output, making it possible to position it up to 100 m away from the LBB 1925/10, using extension cables. Dipswitches on the bottom of the call station configure different pre and post-call chimes, as well as the priority level. LEDs on the call station indicate selected zones, and an additional, two-color LED gives visible feedback on the active state of the microphone and the system. Green indicates microphone on or chime active (flashing LED); amber indicates that the system is occupied by a source with a higher priority or operation error (flashing LED). Controls and indicators • PTT-key • PTT status LED Region Certification Europe CE Declaration of Conformity Safety acc. to EN 60065 Immunity acc. to EN 55103-2 Emission acc. to EN 55103-1 Parts Included Quantity Component 1 LBB 1946/00 Plena Six-zone Call Station 1 5 m cable terminated with a lockable 8-pin DIN connector 1 Loop through 8-pin DIN socket to add an additional call station LBB 1941/00 or LBB 1946/00 www.boschsecurity.com 2 | LBB 1946/00 Plena Six-zone Call Station Technical Specifications Electrical Power Supply Voltage Range 18 to 24 V (24 V supplied by LBB 1925/10) Current consumption <30 mA Performance Nominal sensitivity 85 dB SPL (gain preset 0 dB) Nominal output level 700 mV Maximum input sound level 110 dB SPL Gain preset +6 / 0 / -15 dB Limiter threshold 2V Compression ratio limiter 1:20 Distortion <0.6% (maximum input) Input noise level (equiv.) 25 dB SPLA Frequency response 100 Hz to 16 kHz Speech filter -3dB @ 315 Hz, high-pass, 6 dB/oct Output impedance 200 ohm Selections Chimes 18 different combinations Priorities 2 different priorities Mechanical Base dimensions (H x W x D) 40 x 100 x 235 mm (1.57 x 3.97 x 9.25 in) Weight Approx. 1 kg (2.2 lb) Color Charcoal with silver Stem length with mic 390 mm (15.35 in) Cable length 5 m (16.4 ft) Environmental Operating temperature -10 ºC to +55 ºC (14 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity <95% Ordering Information LBB 1946/00 Plena Six-zone Call Station metal base design, a flexible microphone stem, and a unidirectional condenser microphone. It can make calls to selected zones (one to six and all-call). Americas: Bosch Communications Systems 12000 Portland Avenue South Burnsville, Minnesota 55337, USA Phone: +1-800-392-3497 Fax: +1-800-955-6831 [email protected] www.boschsecurity.com LBB1946/00 Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 [email protected] www.boschsecurity.com © Bosch Security Systems Inc. 011 | Data subject to change without notice T866494731 | Cur: en-US, V25, 27 Jan 2011 Asia-Pacific: Robert Bosch (SEA) Pte Ltd 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2600 Fax: +65 6571 2698 [email protected] www.boschsecurity.com Represented by Plena System Pre-amplifier and Call Stations Installation and Operating Manual en LBB 1925/10, LBB 1941, LBB 1946 Plena System Pre-amplifier | Installation and Operating Manual | Important safeguards en | 3 Important safeguards 1 Read instructions - All the safety instructions for use should be read before the system is operated. 2 Retain instructions - The safety instructions and instructions for use should be retained for future reference. 3 Heed warnings - All warnings on the unit and in the operating instructions should be adhered to. 4 Follow instructions - All operating instructions and instructions for use should be followed. 5 Cleaning - Unplug system units from the mains outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 6 Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards. 7 Water and Moisture - Do not use this unit near water, for example near a bathtub, washbowl, kitchen sink, or laundry basket, in a wet basement, near a swimming pool, in an unprotected outdoor installation or any area which is classified as a wet location. 8 Accessories - Do not place this unit on an unstable stand, tripod, bracket or mount. This unit may fall, causing serious injury to a person and serious damage to the unit. Use only a stand, tripod, bracket or mount recommended by the manufacturer, or sold with the product. Any mounting of the unit should follow the manufacturer's instructions, and should use a mounting accessory recommended by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn. 9 Ventilation - Openings in the enclosure, if any, are provided for ventilation and to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. The unit should not be placed in a built-in installation unless proper ventilation is provided or the manufacturer's instructions have been adhered to. 10 Power sources - Units should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For units intended to operate from battery power, or other sources, refer to the "Installation and User Instructions". 11 Grounding or polarisation - This unit may be equipped with a polarised alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug still fails to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarised plug. Alternatively, this unit may be equipped with a 3-wire grounding type plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type lug. Bosch Security Systems | 2003-09 | 3922 988 99483en 12 Power-Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance. 13 Overloading - Do not overload outlets and extension cords as this can result in a risk of fire or electrical shock. 14 Object and Liquid Entry - Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit. 15 Servicing - Do not attempt to service this unit yourself as opening or removing covers may expose to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 16 Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions: • When the power-supply cord or plug is damaged. • If liquid has been spilled, or objects have fallen into the unit. • If the unit has been exposed to rain or water. • If the unit does not operate normally by following the instructions for use. Adjust only those controls that are covered by the instructions for use, as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the units to their normal operation. • If the unit has been dropped or the unit has been damaged. • When the unit exhibits a distinct change in performance; this indicates a need for service. 17 Replacement Parts - When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or parts which have the same characteristics as the original part. Unauthorised substitutions may result in fire, electric shock or other hazards. 18 Safety Check - Upon completion of any service or repairs to the units, ask the service technician to perform safety checks to determine that the unit is in proper operating condition. 19 Lightning - For added protection of the units during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the cable system. This will prevent damage to the unit due to lightning and power-line surges. Plena System Pre-amplifier | Installation and Operating Manual | About this manual en | 4 About this manual This manual provides all the information required to install and operate the unit. Conventions Warning Follow these instructions to prevent personal injury. Caution Follow these instructions to prevent damage to the equipment. Note Read these instructions for tips and other useful information. Safety precautions Warning Do not open the unit when it is connected to the mains. The unit contains non-insulated parts, which can cause electric shock. Caution There are no user-serviceable parts inside the unit. Service must be done by qualified personnel. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Table of contents en | 5 Table of contents Important safeguards..........................................................................................................................................................3 About this manual ..............................................................................................................................................................4 Safety precautions...............................................................................................................................................................4 Table of contents ................................................................................................................................................................5 1 About the system pre-amplifier .......................................................................................................................................7 1.1 Controls & Connections (front) ...............................................................................................................................8 1.2 Controls & connections (rear) ..................................................................................................................................8 2 Internal settings (system pre-amplifier) ...........................................................................................................................9 2.1 Setting the zones for trigger 1 and 2 .......................................................................................................................9 2.2 Setting tones ..............................................................................................................................................................9 2.3 Setting the Speech filter and call station volume ................................................................................................10 2.4 Setting priority .........................................................................................................................................................10 2.5 Setting single and dual channel use ......................................................................................................................11 2.6 Override contact setting .........................................................................................................................................11 3 Installation in rack (system pre-amplifier) ....................................................................................................................12 4 External settings and connections (system pre-amplifier) ...........................................................................................13 4.1 Connect the DC supply (battery) ..........................................................................................................................13 4.2 Connect a microphone ...........................................................................................................................................14 4.3 Connect the call stations ........................................................................................................................................15 4.4 Connect an emergency input line .........................................................................................................................15 4.5 Connect audio sources for background music .....................................................................................................16 4.6 Connect to a booster ..............................................................................................................................................17 5 Operation (system pre-amplifier) ...................................................................................................................................18 6 About the call stations .....................................................................................................................................................19 6.1 Controls & Connections (top) ................................................................................................................................20 7 Internal settings (call stations) ........................................................................................................................................21 7.1 Chime .......................................................................................................................................................................21 7.2 Setting sensitivity & speech filter ...........................................................................................................................21 8 Operation (call stations) ..................................................................................................................................................22 9 Technical data ..................................................................................................................................................................23 9.1 System pre-amplifier LBB 1925 ............................................................................................................................23 9.1.1 Electrical .............................................................................................................................................................23 9.1.2 Performance .......................................................................................................................................................23 9.1.3 Inputs ..................................................................................................................................................................23 9.1.4 Outputs ...............................................................................................................................................................24 9.1.5 Relays ..................................................................................................................................................................24 9.1.6 Environmental conditions .................................................................................................................................24 9.1.7 General ...............................................................................................................................................................24 9.2 All-call call station LBB 1941 ................................................................................................................................25 9.2.1 Electrical .............................................................................................................................................................25 9.2.2 Performance .......................................................................................................................................................25 9.2.3 Environmental conditions .................................................................................................................................25 9.2.4 General ...............................................................................................................................................................25 9.3 6-zone call station LBB 1946 .................................................................................................................................26 9.3.1 Electrical .............................................................................................................................................................26 9.3.2 Performance .......................................................................................................................................................26 Bosch Security Systems | 2003-09 | 3922 988 92483en Plena System Pre-amplifier | Installation and Operating Manual | Table of contents en | 6 9.3.3 Selections ............................................................................................................................................................26 9.3.4 Environmental conditions .................................................................................................................................26 9.3.5 General ...............................................................................................................................................................26 Chime tone tables.............................................................................................................................................................27 Bosch Security Systems | 2003-09 | 3922 988 92483en Plena System Pre-amplifier | Installation and Operating Manual | About the system pre-amplifier 1 en | 7 About the system pre-amplifier Plena 0 dB Syste m -6 dB -20 dB Pre-am plifier Powe r Selec /Line CD t AUX Z1 + Z4 + Z2 Z5 Z3 Z6 Figure 1.1 Block Diagram LBB 1925/10 Tone B1 Call 100V Tone 1 B2 Chime 0 1 2 Tel/EMG J2 CAll & BGM 0V BGM 100V 1 2 3 4 Alarm/Timer/Chime Tone Call Station In Use Zone 1,0V Out Call 0V S301 5 6 7 8 Zone 1,100V Out BGM 0V LBB1941/00 RA1 24V DC Trigger 1 Z1 Z2 Z3 Z4 Z5 Z6 A1 Alarm/Timer R1 S302 Front panel Key switch Zone 1 override J4 Tigger 1 Trigger 2 1 2 3 4 5 6 7 8 VOX Zone 1 RB1 Call active Tone Alarm/Timer Z1 Z2 Z3 Z4 Z5 Z6 A2 M.C.U. S303 Zone 2,0V Out Tigger 2 CAll & BGM 0V 1 2 3 4 5 6 7 8 VR1 P.S. RA2 Speech filter JP101 ON/OFF S101 200mV Zone 2 override Front panel Key switch VU LED Announcement Tone Control 1mV /Line Zone 2,100V Out Priority Zone 2 RB2 Master out Zone 3,0V Out CAll & BGM 0V Out Zone 3,100V Out RA3 CD Selector JP102 Music Tone Control O Headphone 1-CH use 2-CH use Zone 3 override Front panel Key switch Zone 3 RB3 Aux Zone 4,0V Out CAll & BGM 0V O PC Audio In Interface VR101 Zone 4,100V Out RA4 Zone 4 override Front panel Key switch RS-485 Zone 4 RB4 Zone 5,0V Out CAll & BGM 0V RS-232 F1 115V/230V F101 F102 24V DC Zone 5,100V Out + RA5 24V DC OUT 0.5A 0.5A - 0.5A Zone 5 override Front panel Key switch Zone 5 RB5 18V DC + F101 - 1.5A Zone 6,0V Out CAll & BGM 0V 24V DC IN Zone 6,100V Out RA6 Zone 6 override Front panel Key switch Zone 6 RB6 Figure 1.2 The Plena System Pre-amplifier is a mono amplifier, which mixes a call-station signal with a background music signal. You can adjust the volume and tone for both signals. The background music channel has 3 possible inputs (CD, Tape and AUX) and a direct XLR output for 2-channel use. Internal relays control the audio routing to the 6 zones. The zone selection keys at the front determine to which zones the background music is send. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | About the system pre-amplifier en | 8 1.1 Controls & Connections (front) Plena System Pre-amplifier 1 Select 0 dB Z1 CD -6 dB Z2 Z3 AUX 11 -20 dB 2 Z4 /Line Power Z5 Z6 3 0 0 4 5 6 7 8 9 10 Figure 1.3 1 2 3 4 5 6 VU meter (LED bar) Power on indication LED (green) Power on/off Volume control, mic/line Tone control, mic/line Volume control, background music 7 8 9 10 11 Background music selection switch Tone control, background music Zone selection keys, background music Headphone connection Indication LED, call station active 1.2 Controls & connections (rear) 11 12 Tel/EMG 13 14 Trigger 1 Trigger 2 16 15 7 17 18 19 20 Apparatus delivered 115V connected for 230V- LBB1925/10 890019251005 115/230V~,50/60Hz No. 230V 21 0 1. Audio+ 2.0V 3.Audio4.24Vd.c. /Line 5. Allcall 6.DataPCAudoln 7.Data+ 8.Chs.GND CD RS232 Aux L /Line + 2 GND GND 1 1 3 100V 0 3 5 3 1 5 1 3 22 2 Rated Input Power : 50VA T0.5L 250V 100V 0 1 MasterOut 4 100V 0 + - 100V 0 100V 0 100V 0 +24V- 6 8 5 4 2 100V 0 3 R 7 14 100V 0 Out +24VWarning This apparatus must be earthed 2 2 3 4 5 6 7 8 9 Figure 1.4 1 2 3 4 5 6 7 8 9 10 11 Mic/line input (DIN) Mic/line input (XLR) Call station input (8-pin DIN) Audio input from PC (Cinch) Master output (XLR) Background music output (XLR) 100V LSP output (zone 1 to 6) 24V DC output for relays (terminal) 24V DC input (terminal) Earth connection screw Volume control (Tel/Emergency input) Bosch Security Systems | 2003-09 | 3922 988 99483en 12 13 14 15 16 17 18 19 20 21 22 Telephone/Emergency signal input Alarm/time signal, trigger inputs Control input for PC (RS232; 9-pin) CD/ Tape/Auxiliary input (Cinch) Tape output (Cinch) Call active control output (terminal) Call input from booster (terminal) Music input from booster (terminal) Mains voltage switch (115/230V) Mains socket Mains fuse 10 Plena System Pre-amplifier | Installation and Operating Manual | Internal settings 2 en | 9 Internal settings (system pre-amplifier) CN104 1925-8 CN103 S301 1 ON B1 B2 CN101 1 1941 8 1 ON ZONE 1 2 3 4 5 6 S302 A1 CHIMEVOL. 8 VR1 CND001 CND003 CND002 ON 1 ZONE 1 2 3 4 5 6 S303 A2 8 CN105 CND102 Figure 2.1 2.1 Setting the zones for trigger 1 and 2 Trigger inputs 1 and 2 on the rear panel may start alarm or time signals upon closing its contact. The zones for trigger 1 can be set with S302 (bit 1 to 6), for trigger 2 with S303 (bit 1 to 6). The selected zones receive a time or alarm tone when the trigger is activated. Time tones are edge triggered and last the duration of the chime. Alarm tones are level triggered and last until released. 2.2 Setting tones The time or alarm tone for trigger 1 can be set with S301 (bit 1 and 2) and S302 (bit 7 and 8), for trigger 2 with S301 (bit 3 and 4) and S303 (bit 7 and 8). If you use a LBB 1941 call station, the chime tone must be set with S301 (bit 6 to 8). You can find the chime tone tables at the end of the manual. With S301 (bit 5) the 2-tone chime on the DIN priority contact for mic/line can be enabled or disabled. The 2-tone chime is 554 Hz (1s), 440 Hz (1s). You can set the chime volume with VR1. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Internal settings en | 10 2.3 Setting the Speech filter and call station volume CN21 CN24 MASTER OUT SWITCH XLR DIN JP101 OFF ON CN4 C179 J2 25-1 1 CH USE LINE CALL STATIONS PC AUDIO IN VR101 CALL STATION LEVEL U106 MUSIC OUT CN9 2 CH USE RL701 D701 CN1 CN107 R701 CN6 CN14 CN17 Q701 CN10 CN23 CN8 25-7 3938 101 90282 Figure 2.2 JP102 1 CH USE CN18 2 CH USE Figure 2.3 The Speech filter for the mic/line input can be switched on/off with jumper JP101 (default ON). You can set the call station volume with VR101. 2.4 Setting priority The priority cannot be set manually. The default priority order is: 1 Emergency/Telephone input 2 Trigger 1 or 2 (first comes, first served) 3 All-call call station LBB 1941 4 6-zone call station LBB 1946 (DIP switch setting of LBB 1946) 5 6-zone call station LBB 1946 (DIP switch setting of LBB 1946) 6 Background music and mic/line input Bosch Security Systems | 2003-09 | 3922 988 99483en CN13 Plena System Pre-amplifier | Installation and Operating Manual | Internal settings en | 11 2.5 Setting single and dual channel use The system pre-amplifier can be used with one booster amplifier for both music and calls ('1 channel use'). Any call will interrupt background music in all zones. It is also possible to use separate booster amplifiers, for music and calls ('2 channel use'). Now a call will not interrupt music in zones, not addressed by the call. Jumper JP102 selects whether background music is going to the Master output (1 channel use) or not (2 channel use). Jumper J2 must be set to either 1 channel use or 2 channel use to select the amplifier terminals for the zones. 2.6 Override contact setting 3-wire (zone 1-6) D614 RL606 RL605 D613 RL604 RL603 RL602 RL601 100V CN24 OVERRIDE CN20 LOCAL VOLUME CONTROL CN3 CN21 D606 RL612 D604 RL610 D603 RL609 D602 RL608 D601 RL607 4-wire (zone 1-6) 0V CN22 D605 RL611 Figure 2.5 100V 24V RL612 J3 LOCAL VOLUME CONTROL AMPLIFIER 100V audio 24V dc J4 Override 0V AMPLIFIER RL611 RL610 RL608 RL609 25-6 OVERRIDE RL607 3938 101 90272 Figure 2.4 DC Out 24V (-) Figure 2.6 Jumpers J3 and J4 select whether the override output for each zone (indicated by ) is switching between the 0V and 100V loudspeaker signal, or between ground and 24Vdc. This override output is available per zone and may be used to override local volume controls, to make sure that calls are coming through. For 3-wire volume override, the jumpers should be in 100V audio position. For 4-wire override the jumpers should be in 24Vdc position. The drawings show the principle of 3- and 4-wire volume override. The override outputs are activated whenever a call is made, when the emergency input is activated, or an alarm or time signal is triggered. At the same time also the Call Active relay is activated, providing a potential free contact. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Installation in rack 3 Installation in rack (system pre-amplifier) Plena 0 dB -6 dB -20 dB Syste mP re-am plifier Powe r /Line Sele ct CD AUX Z1 + Z4 + Z2 Z5 Z3 Z6 Figure 3.1 The system pre-amplifier is delivered for tabletop use, but you can mount it in a 19" rack. If you mount the pre-amplifier in a rack, you must: • use the mounting brackets delivered with the unit. • remove the 4 feet from the bottom of the unit. (Without the feet the unit is 2U high.) Bosch Security Systems | 2003-09 | 3922 988 99483en en | 12 Plena System Pre-amplifier | Installation and Operating Manual | External settings and connections 4 en | 13 External settings and connections (system pre-amplifier) 4.1 Connect the DC supply (battery) 6 Call Activ e Ca ll In Appa ra conn tus deliv ere ected for 2 d 30V- In 00V 0 Zone 100V 115V - 23 0 Tel/E MG Trigge r1 3 Zone 100V 4 0 1 00V 0 DC O ut DC In /Line Trigge r2 LBB1 925/0 8900 0 115/21925 0005 30V~ No. ,50/6 0Hz 0 1.Au dio+ 2.0V 5.Allc all 3.Au dio- 6.Data4.24V 7.Da ta+ d.c. 8.Ch s.GN /Line 14 3 5 PCAu D dioIn RS23 2 3 Zone CD 1 5 2 Zone 2 6 8 5 2 1 R 3 GND 1 GND 1 - + 100V 2 Zone 3 4 Appa ratus conn ected delivered for 230V - 115V - 230V - In In 0 2 Zone 100V 3 Zone 100V 0 4 100V DC Out 0 100V 0 100V 100V 0 100V 0 DC In 0 +24V - +24V - Rated input Power : T1.0A 50VA L 250V Warni 0 This +24V - 12 V D Activ e Call 100V Zone Out + Call 0 1 ut 0 6 Aux + 7 3 MasterO 0V 5 L 4 +24V - Warni ng This appa ratus - must be ng appara tus must be earthe d earth ed F F = 1.5A + - C 12 V D C Figure 4.1 The system pre-amplifier has a 24 Vdc input (terminal screw), which you can use to connect a back up power supply, e.g. batteries. You can earth the unit to increase the electrical stability of the system. Caution The connection cable must have an in-line fuse. Use the type of fuse as mentioned in the illustration. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | External settings and connections en | 14 4.2 Connect a microphone Tel/E MG /Line Tel/E MG 0 r1 Trigg er 1 Trigg er 2 LBB1 925/0 8900 0 115/21925 0005 30V~ No. ,50/6 0Hz 1.Au dio+ 2.0V 5.Allc all 3.Au dio- 6.Data4.24V 7.Da ta+ d.c. 8.Ch /Line s.GN D Trigge Trigge 14 r2 3 5 PCAu dioIn RS23 2 3 CD Zone 1 5 2 L 4 2 0 1.Au di 2.0V o+ 5.Allc al 3.Au 6.Dat l di 4.24 o- 7.DataVd.c. a+ 8.Chs /Line .GND 14 3 5 7 3 2 R 3 Zone GND 1 GND 1 - + 100V 2 3 6 Call Activ e Call In 0 100V Zone 100V Zone 2 100V 0 Zone 1 Zone 0 100V 0 2 DC Out 100V 0 z 100V Appa conn ratus delivi ected red for 230V In - 115V - 230V - 0 1 Out 0 100V DC In 0 +24V - +24V - Rated input Power : T1.0A 50VA L 250V Warni ng This appara tus must be earthe d PCAu di oIn RS2 32 1 2 1 4 MasterO ut 3 5 6 8 5 5 Aux + /Line LB B1 92 89 00 5/ 00 19 25 115/23 00 05 No. 0V~,50/6 0H CD L 4 + 2 7 3 6 8 5 2 1 R - GND 1 3 4 - GND 1 3 Maste rOut Out GND GND 180 5-pole DIN 180 3-pole XLR Figure 4.2 The input channel has 2 possible balanced inputs, use one of these inputs to connect a microphone or a line-level source. If you use an input make sure that the 'mic/line' switch is in the correct position. Note If you want to use the priority feature, you must use a microphone or line-level source with a priority contact on pin 4 and 5 of the 5-pole DIN plug. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | External settings and connections en | 15 4.3 Connect the call stations Tel/EMG Trigger 1 Trigger 2 LBB19 89001 25/00 /Line Tel/E MG er 1 115/2392500 05 No. 0V~,50/60Hz 0 1.Audio 2.0V + 5.Allca 3.Audio 6.Data ll 4.24Vd - 7.Data.c. 8.Chs. + GND Trigg /Line Trigg 14 er 2 3 5 PCAud ioIn RS232 Zone CD 3 1 5 2 Zone 2 3 5 6 8 5 2 R 1 - 6 Call Active Call GND GND 1 3 1 - + 100V 2 3 4 Zone 1 rOut In In 100V 2 115V- 230V- 0 Zone 100V 3 Out Zone 0 100V 4 DC Out 100V Appara connectus delivire ted for d 230V- 0 Zone Maste 0 DC In 0 100V 0 100V 0 100V 0 +24V+24V- 1.Aud 2.0V io+ 5.Allc all 3.Aud 6.Data 4.24Vio- 7.Datad.c. 8.Chs + /Line .GND 14 3 LB B1 92 89 00 5/0 0 115/219 25 00 05 30V~ No. ,50/60 Hz 0 Aux + 7 /Line 5 L 4 Rated input Power : T1.0AL 50VA 250V Warning This apparatu s must be earthed PCAu dioIn RS23 2 3 CD 1 5 2 L 4 + 7 3 2 6 8 5 2 1 R - GND 1 3 4 Maste rOut Out A B B A Figure 4.3 You can connect 2 Plena Call Stations directly to the system pre-amplifier. To connect up to the maximum of 8 call stations you must use a loop through connection. The loop through can contain both types of call stations. 4.4 Connect an emergency input line Tel/EM G /Line Trigge r1 Trigge r2 LBB19 89001 25/00 115/2392500 05 No. 0V~,50/60H 0 1.Aud 2.0V io+ 5.Allc all 3.Aud 6.Data 4.24Vio- 7.Datad.c. 8.Chs + .GND /Line 14 3 5 PCAud z ioIn RS232 1 5 2 Zone CD 3 5 L 4 Zone 2 6 8 5 2 1 R 3 Call Active GND 1 GND 1 - + 100V 2 3 4 6 Aux + 7 3 Call Appar conneatus delivir cted ed for 230V- In In 0 115V- 100V 230V- 0 Mast erOu Zone t 1 Zone 100V 2 Out 100V Zone 0 1 0 Zone 100V 2 DC Out 100V 0 100V 0 100V 0 DC In 0 +24V+24V- Tel/E MG This er 1 /Line 0 3 5 LB B1 92 89 00 5/ 00 19 25 115/23 00 05 No. 0V~,50/6 0H PCAu 1 2 be earthed z dioIn 3 5 apparat us must Trigg er 2 1.Au dio 2.0V + 5.Al lca 3.Au 6.Da ll dio ta 4.24 - 7.Da Vd.c. ta 8.Ch + /Line s.GND 14 Rated Power input T1.0AL: 50VA 250V Warnin g Trigg RS23 2 CD L 4 7 3 6 8 5 2 1 R 4 Maste rOut Out Figure 4.4 You can use this input for emergency announcements and/or signals. This channel has the highest priority and is always transmitted to all zones. The emergency line has it's own volume control on the rear, this volume is not affected by the master volume. If a priority microphone, call station, emergency input or trigger input is activated, the Call Active relay is closed and the override contacts of the selected loudspeaker zones are activated. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | External settings and connections en | 16 4.5 Connect audio sources for background music Tel/EM G Trigge r1 Trigge r2 /Line LBB1 925/0 89001 0 115/2 92500 05 30V~, No. 50/60 0 1.Aud 2.0V io+ 5.Allc all 3.Aud 6.Dat 4.24Vio- 7.Datad.c. a+ 8.Chs .GND /Line 14 3 5 Hz PCAu dioIn RS232 3 1 5 2 Zone CD L 4 2 6 8 5 2 1 5 Zone + 7 3 R Aux 3 1 GND 1 - Call Active + 2 Zone 100V 1 100V 2 Out 0 100V 0 Appar conneatus delivir cted ed for 230V- In 100V 0 115V- 230V- 0 Zone t 100V Call In 0 Zone Mast erOu Tel/E MG 6 GND 3 4 100V 0 Zone 4 3 100V 100V DC Out 0 DC In 0 +24V+24V- Trigg Warnin er 1 This Trigg Rated Power input T1.0AL: 50VA 250V g apparat us must be earthed er 2 LB B1 92 89 00 5/0 0 115/219 25 00 05 30V~ No. ,50/60 Hz 0 1.Aud 2.0V io+ 5.Allc all 3.Aud 6.Data 4.24Vio- 7.Datad.c. 8.Chs + .GND R /Line PCAu dioIn 1 RS23 2 CD L 4 + 2 7 3 6 8 5 2 R 1 3 Aux GND 1 GND 1 - + 2 100V 3 4 Maste 0 Zon 2 rOut Out 100V Plena BGM Power 0 100V 0 100V Source Repeat Program Folder CD/MP 3 W FM/AM M1/6 M2/7 M3/8 M4/9 M5/10 Scan Program TAPE Figure 4.5 The system pre-amplifier has 3 connections for background music (CD, Tape & Auxiliary). You can connect 3 units but only one of the inputs is used depending on the selection switch at the front. It is also possible to use the output of a PC soundcard to supply music or time signals to the system pre-amplifier. To do so connect the soundcard output to the 'PC Audio ln' input. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | External settings and connections en | 17 4.6 Connect to a booster Tel/E MG Trigg er 1 /Line 0 Trigg er 2 LBB 192 890 019 5/00 250 005 115/230V ~,50/60H No. 1.Au dio+ 2.0V 5.Allcall 3.Au dio- 6.Data4.24 Vd.c 7.Data+ . 8.Ch /Line s.GN 3 5 z PCA udioIn D 14 RS2 32 3 1 5 2 Zone CD 5 L 4 Zone 6 Aux + 2 7 3 6 8 5 2 1 R 3 Call GND 1 GND 1 - + 100V 2 3 4 100V 0 Zone 1 Zon e2 Out 100V 0 100V Activ e Call Apparat conn us delivired ected for 230V In - 115V230V - In 0 Master Out Zone 1 Zone 2 100V DC Out 0 DC In 0 0 100V 0 100V 100V 0 +24V- +24V- Rate Powed input T1.0Ar : 50VA L 250V Warn ing This appa ratus must + 1 100V 3 0V GND 2 GND 1 3 + 2 be earth ed 100V 100V line out 70V 0 230V - 240V 0 8 24V - DC IN + Line fuse 250V T1A Warn This ing appa ratus + 1 100V 0V 3 GND 2 GND 1 3 must Apparat conn us deliv ected ered for 230V - be earth ed + 2 100V 100V line out 70V 0 230V - 240V 0 8 24V - DC IN + Line fuse 250V T1A Warn This ing appa ratus must Apparat conn us deliv ected ered for 230V - be earth ed Figure 4.6 The system pre-amplifier has a master and a music output that can be connected to 1 or 2 boosters for single or dual channel operation. For single channel operation connect the Master output to the booster. The signal from the booster must be returned to the 'Call in' (terminal) of the system pre-amplifier. For dual channel operation you must also connect the Music output to a second booster. The signal from this booster must be returned to the 'Music in' (terminal) of the system pre-amplifier. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Operation 5 en | 18 Operation (system pre-amplifier) Plena 0 dB -6 dB Syste m Pre-a mplifie r -20 dB Powe r /Line Selec t CD AUX Z1 + Z4 + Z2 Z5 Z3 Z6 Figure 5.1 You can adjust the volume and tone for the mic/line input with the knobs on the left panel. The knobs for background music selection, volume and tone are on the centre panel. To select the zones to which the background music must be send press the keys on the right hand panel. When a zone is active the indication LED is on. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | About the call stations 6 en | 19 About the call stations Figure 6.1 Gain Preset 6 dB JP2 JP3 0 dB JP4 -15 dB Speech filter ON/OFF Mic. JP5 + Balance out 1 3 Phantom Supply P.S. 4 Power Supply Green Amber - 2 Press to Talk Amber All Zone RS-485 Amber M.C.U. Z1 6 Driver/Receiver 7 Amber Z2 Amber Z3 Priority Amber Z4 Amber Z5 Internal Chime Select External Chime Select 8 Chassis Ground ON 1 2 5 NC 3 4 5 6 Priority level/chime tone pre-set 7 8 LBB1946 LBB1941 Amber Z6 Figure 6.2 The Plena Call Stations must be used in combination with the system pre-amplifier LBB 1925. Both call stations have a loopthrough connection to add an additional call station. The 6-zone call station (LBB 1946) has the possibility to send a message to one zone, a group of zones or all zones. The all-call call station (LBB 1941) can only send a message to all zones. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | About the call stations en | 20 6.1 Controls & Connections (top) 5 1 2 3 4 1 4 Figure 6.3 1 2 3 4 5 Microphone Zone selection keys with indication LED All zone selection key with indication LED Press to talk key with indication LED Labels for zone indication. Note An editable label template (MS Word) can be downloaded from www.boschsecuritysystems.com / www.philipscsi.com. The call stations LBB 1941 and LBB 1946 can be connected in a loop-through arrangement to the LBB 1925. Each input of the LBB 1925 can have up to 4 call stations. The call station cable may be extended up to 500 m from the LBB 1925, using shielded CAT-5 quality cable (four twisted pairs with one overall shield) and 8-pin DIN connectors. One twisted pair for power supply connection (DIN pin 4: 24Vdc, pin 2: ground), one twisted pair for data communication (DIN pin 6: data -, pin 7: data +), one twisted pair for audio (DIN pin 1 and pin 3) and one twisted pair for all-call select (DIN pin 5) and connection to chassis ground (DIN pin 8). Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Internal settings 7 en | 21 Internal settings (call stations) 7.1 Chime CN3 0dB -15dB CN2 JP5 OFF ON +6dB U4 Priority S8-1 S8-2 Priority 2 (highest) 0 1 Priority 1 (lowest) 1 0 not allowed 0 0 not allowed 1 1 VR1 JP2 JP3 JP4 CN1 ON S8 1 8 Figure 7.1 The chime for the all-call call station (LBB 1941) is set inside the LBB 1925 system pre-amplifier. The chime for the 6-zone call station (LBB 1946) is set within the call station with DIP switch S8 (bit 3 to 8). The chime volume can be set with VR1. You can find the chime tone tables at the end of the document. The priority for a call station (LBB 1946) can be set with the switch S8 (bit 1 and 2) as shown in figure 7.1. 7.2 Setting sensitivity & speech filter Symm. Output level (dBV) Input/Output ratio 20:1 +6.8dBV +6dBV +6 dB 0 dB -15 dB Jumper Settings JP2 +6dB JP3 0dB JP4 -15dB -3dBV +79 +85 +94 +100 +124 Acoustical input level (dBSPL) Figure 7.2 The sensitivity of the call station microphone can be set with the jumpers JP2, JP3 and JP4. Which jumper activates which sensitivity can be found in the table. The speech filter can be enabled or disabled with jumper JP5. Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Operation 8 en | 22 Operation (call stations) Figure 8.1 The call station LBB 1941 can only send a call to all zones. With the call station LBB 1946 you can select to which zones your call is sent. To do so press the zone keys or the all-zone key. When a zone is selected the indication LED is on. To send a call press the PTT key and wait until the indication LED is green, then talk in the microphone. The indication LED can give the following indications. Indication LED of PTT button Call station type Yellow The system is occupied. Only LBB 1946 Yellow flashing The PTT key is pressed, but no zones were selected. Only LBB 1946 Green The microphone is on. Both Green flashing The chime tone is active. Only LBB 1946 Bosch Security Systems | 2003-09 | 3922 988 99483en Plena System Pre-amplifier | Installation and Operating Manual | Technical data 9 Technical data 9.1 System pre-amplifier LBB 1925 9.1.1 Electrical Mains voltage Max mains power consumption Battery voltage Max battery current 230 V/115 Vac, (15%, 50/60 Hz) 50 VA 24 Vdc, +20%/-10% 1A 9.1.2 Performance Frequency response Distortion Call channel Bass control Treble control BGM channel Bass control Treble control Channel separation at 1kHz Priority mute 50 Hz - 20 kHz (+1/-3 dB) <0.5% -6/+6 dB at 160 Hz 0/+12 dB at 5 kHz 0/+20 dB at 100 Hz 0/+18 dB at 15 kHz >65 dB >50 dB 9.1.3 Inputs Call station inputs (8-pin DIN, balanced, for LBB1941/00 and/or LBB1946/00) Sensitivity 1V Data RS485, 1200, N, 8, 1, 0 Mic/Line input (3-pin XLR/5-pin DIN, balanced) Sensitivity 1 mV (microphone), 200 mV (line) Impedance >1 kOhm (microphone), >5 kOhm (line) S/N (flat at max volume) >63 dB (microphone), >70 dB (line) S/N (flat at min volume/muted) >75 dB CMRR >40 dB (50 Hz - 20 kHz) Headroom >25 dB Speech filter -3 dB at 315 Hz, high-pass, 6 dB/oct Phantom power supply 16 V via 1.2 kOhm, in microphone mode only BGM input (Cinch, unbalanced, stereo converted to mono) Sensitivity 500 mV (CD), 200 mV (aux, tape) Impedance 22 kOhm S/N (flat at max volume) >70 dB S/N (flat at min volume/muted) >75 dB Headroom >25 dB PC input (Cinch, unbalanced, stereo converted to mono) Sensitivity 1V Impedance 22 kOhm S/N >70 dB Bosch Security Systems | 2003-09 | 3922 988 99483en en | 23 Plena System Pre-amplifier | Installation and Operating Manual | Technical data Emergency/telephone input (Screw, balanced) Sensitivity 100 mV to 1V adjustable Impedance >10 kOhm VOX threshold 50 mV S/N >65 dB 9.1.4 Outputs Master output (3-pin XLR, balanced) Nominal level Impedance 1V <100 Ohm BGM output (3-pin XLR, balanced) Nominal level Impedance 1V <100 Ohm Tape output (Cinch, 2x mono) Nominal level Impedance 350 mV 3.3 kOhm Headphone output (6.3-mm jack stereo, signal mono) Nominal level 3V Impedance <100 Ohm Control RS232 (9-pin D-sub) Baud rate 19K2 Trigger inputs (Screw) Activation contact closure 9.1.5 Relays Priority relay contacts Zone output relay contacts DC supply output voltage 100 V, 2 A 100 V, 2 A 24 V, 250 mA max 9.1.6 Environmental conditions Operating temperature range Storage temperature range Relative humidity -10 to +55°C -40 to +70°C <95% 9.1.7 General EMC emission EMC immunity Dimensions Weight 19” mounting brackets included acc. to EN 55103-1 acc. to EN 55103-2 100 x 430 x 270 mm (19” wide, 2U high) approx. 5 kg Bosch Security Systems | 2003-09 | 3922 988 99483en en | 24 Plena System Pre-amplifier | Installation and Operating Manual | Technical data 9.2 All-call call station LBB 1941 9.2.1 Electrical Power supply Voltage range Current consumption 18 to 24 V (24 V supplied by LBB1925/10) <30 mA 9.2.2Performance Nominal sensitivity Nominal output level Maximum input sound level Gain preset Limiter threshold Compression ratio limiter Distortion Equivalent input noise level Frequency response Speech filter Output impedance 85dBSPL (gain preset 0dB) 700mV 110 dB SPL +6/0/-15 dB 2V 1:20 <0.6% (maximum input) 25 dBA SPL 100 Hz to 16 kHz -3 dB at 315 Hz, high-pass, 6 dB/oct 200 Ohm 9.2.3Environmental conditions Operating temperature range Storage temperature range Relative humidity -10 to +55°C -40 to +70°C <95% 9.2.4General EMC emission EMC immunity Dimensions Weight Cable length acc. to EN 55103-1 acc. to EN 55103-2 40 x 100 x 235 mm (base) 390 mm stem length (with microphone) approx. 1 kg 5 m (may be extended up to 500 m using CAT-5 style shielded cable) Bosch Security Systems | 2003-09 | 3922 988 99483en en | 25 Plena System Pre-amplifier | Installation and Operating Manual | Technical data 9.3 6-zone call station LBB 1946 9.3.1 Electrical Power supply Voltage range Current consumption 18 to 24 V (24 V supplied by LBB1925/10) < 30 mA 9.3.2Performance Nominal sensitivity Nominal output level Maximum input sound level Gain preset Limiter threshold Compression ratio limiter Distortion Equivalent input noise level Frequency response Speech filter Output impedance 85 dB SPL (gain preset 0 dB) 700 mV 110 dB SPL +6/0/-15 dB 2V 1:20 < 0.6% (maximum input) 25 dBA SPL 100 Hz to 16 kHz -3 dB at 315 Hz, high-pass, 6 dB/oct 200 Ohm 9.3.3Selections Chimes Priorities 18 different combinations 2 different priorities 9.3.4Environmental conditions Operating temperature range Storage temperature range Relative humidity -10 to +55°C -40 to +70°C < 95% 9.3.5General EMC emission EMC immunity Dimensions Weight Cable length acc. to EN 55103-1 acc. to EN 55103-2 40 x 100 x 235 mm (base) 390 mm stem length (with microphone) approx. 1 kg 5 m (may be extended up to 500 m using CAT-5 style shielded cable) Bosch Security Systems | 2003-09 | 3922 988 99483en en | 26 Plena System Pre-amplifier | Installation and Operating Manual | Chime tone tables en | 27 Chime tone tables Trigger 1 B1 S301-1 B2 S301-4 S301-3 0 0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 S301-2 Trigger 2 Slow whoop 500 to 1200Hz sweep in 1 s and pause for 1 second Din alarm 1200 to 500Hz sweep in (1s) Evacuation 554Hz (100ms), 440Hz (400ms) Immediate danger 600Hz (200ms), pause (200ms) Fire alarm 440Hz (12s on, 12s off) 600Hz continuous Two-tone alarm 440Hz (1s), 554Hz (1s) Pulse alarm 1000Hz (300ms), pause (200ms) 1.2kHz (1s) 554Hz (2s) 440Hz (4s) 554Hz (2s) 554Hz (1s), 440Hz (1s) 392Hz (1s), 523Hz (1s), 659Hz (2s) 554Hz (1s), 440Hz (1s), 493Hz (1s), 330Hz (2s) 659Hz (1s), 523Hz (1s), 392Hz(1s), 330Hz (2s) Tone LBB 1941 No Chime 554Hz (1s) 554Hz (1s), 440Hz (1s) 392Hz (1s), 523Hz (1s), 659Hz (2s) 554Hz (1s), 440Hz (1s), 493Hz (1s), 330Hz (2s) 196Hz (1s), 262Hz (1s), 330Hz (1s), 392Hz (2s) 392Hz (1s), 523Hz (1s), 659Hz (2s) and release tone in reverse order 196Hz (1s), 262Hz (1s), 330Hz (1s), 392Hz (2s) and release with tones 659Hz (1s), 523Hz (1s), 392Hz (1s), 330Hz (2s) Bosch Security Systems | 2003-09 | 3922 988 99483en S301-8 0 0 0 0 1 1 1 1 S301-7 0 0 1 1 0 0 1 1 A1 S302-8 S302-7 A2 S303-8 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 S302-6 0 1 0 1 0 1 0 1 S303-7 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Plena System Pre-amplifier | Installation and Operating Manual | Chime tone tables LBB1946 DIP-SWITCH setting for chime and priority 554Hz (1s), 440Hz (1s) 554Hz (1s), 440Hz (1s), 493Hz (1s), 330Hz (2s) 196Hz (1s), 262Hz (1s), 330Hz (1s), 392Hz (2s) No Chime 440Hz (1s) 554Hz (1s) 392Hz (1s), 523Hz (1s), 659Hz (2s) 392Hz (1s), 523Hz (1s), 659Hz (2s) and release with tones in reverse order 554Hz (1s), 440Hz (1s) and released with 330Hz (1s), 440Hz (1s) 554Hz (1s), 440Hz (1s), 493Hz (1s), 330Hz (2s) and release with tone in reverse order 554Hz (1s), and release with 440Hz (1s) 196Hz (1s), 262Hz (1s), 330Hz (1s), 392Hz (1s) and release with 659Hz (1s), 523Hz (1s), 392Hz (1s), 330Hz (2s) 440Hz (0.5s) 554Hz (0.5s), 440Hz (0.5s) 392Hz (0.5s), 523Hz (0.5s), 659Hz (0.5s) 392Hz (0.5s), 523Hz (0.5s), 659Hz (0.5s) and release with tone in reverse order 554Hz (0.5s), 440Hz (0.5s), 493Hz (0.5s), 330Hz (1s) 554Hz (0.5s), 440Hz (0.5s), 493Hz (0.5s), 330Hz (1s) and release with tone in reverse order 196Hz (0.5s), 262Hz (0.5s), 330Hz (0.5s), 392Hz (0.5s) and release with reverse 659Hz (0.5s), 523Hz (0.5s) 392Hz (0.5s), 330Hz (1s) Priority level 2 Priority level 1 No allowed en | 28 Chime selection BIT8 0 1 BIT7 1 0 BIT6 x x BIT5 x x BIT4 x x BIT3 x x Priority selection BIT2 BIT1 - 1 1 x x x x - - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1 1 0 0 1 0 1 0 x x x x x x x x 0 0 0 1 0 1 x x 0 0 0 1 1 0 x x 0 0 0 1 1 1 x x 0 0 1 0 0 0 x x 0 0 0 0 0 0 1 1 1 0 0 0 0 1 1 1 0 1 x x x x x x 0 0 1 1 0 0 x x 0 0 1 1 0 1 x x 0 0 1 1 1 0 x x 0 0 1 1 1 1 x x x x x x x x x x x x x x x x x x x x 1 0 1 0 1 1 Bosch Security Systems | 2003-09 | 3922 988 99483en For more information visit www.boschsecuritysystems.com © Bosch Security Systems B.V. Data subject to change without notice 2003-09 | 3922 988 99483en