Download Sharp IV-C35M User`s manual

Transcript
Communication (General Purpose Serial Interface)
Station
: No.
2 8
Execution
camera
(5) Illuminance level reading: code 28(H)
The illuminance level measured by the illuminance monitor function and the evaluation result are
read.
Ë Command
SC SC CR
(H) (L)
Object
Station
type
No.
:
2 8 RC RC
(H) (L)
Result
Ë Response
Illuminance
SC SC CR
102 101 100 10-1 (H) (L)
- Camera No. → 0: camera 1, 1: camera 2
- Object type → Object type for which the measurement was executed: 00 to 0F
- Result
→ 0: NG, 1: OK
- Illuminance → 000.0 to 255.0
Execution
camera
(6) Corrected light level reading: code 29(H)
The corrected light level measured by the illuminance monitor function, the evaluation result and
preset reference light level are read.
Ë Command
- Camera No. → 0: camera 1, 1: camera 2
Station
No.
:
2 9
SC SC CR
(H) (L)
Object
Station
type
No.
:
2 9 RC RC
(H) (L)
Result
Ë Response
Corrected
Reference
light level
light level
SC SC CR
± 102 101 100 10-1102 101 100 10-1 (H) (L)
- Object type → Object type for which the measurement was executed: 00 to 0F
- Result → 0: NG, 1: OK
- Corrected light level → Corrected light level (–0 to 255.0)
- Reference light level → Light level used as the criterion (0 to 255.0)
22