Download Sharp IV-S30 User`s manual
Transcript
Multiple Degree of Match Inspection Set the evaluation conditions How to move to the evaluation condition setting screen There are two methods for getting to the evaluation condition setting screen. 1) Select "COND" in the upper function menu on the "MEAS COND (or REG COND)" screen and press the SET key. Select "EVALUATION" on the pop up menu to go to the "EVALUAT COND" screen. MEAS CND SCREEN COND SAVE F C1 BRT IMG PRE-PROC REG-COND EVALUATION DST&ANGL NUM-CALC OUT 1DTECT PRECISION 2REGISTER NO. 3MODE 4MATCHING 5DETECT ORDER STANDARD 0(0~3) YES AVG-GRAYS SCAN-ORDER REGISTER NO. 6DTECT OBJECT 0001020304 05 060708 09 101112131415 S ××× SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC 2) Move the cursor to the "EVALUATION COND" item on the menu tree screen and press the SET key. SELECT OBJECT TYPE COND F C1 BRT OBJECT TYPE COND + TYPE00 1REGISTER NO. TYPE RUN COND 2CONDITION SET IMAGE-ADJ 3NUMBER OF OBJ MEA-CND(CAMERA1) 4DTECT NUMBER MEAS0 5MATCH LVL POSI-CORRECT 6GRAY LVL MEAS01(MULTI MATCHES) 7TEST IMG PRE-PROC MEAS CND REG-COND EVALUATION COND + DISTANCE&ANGLE COND NUM-CALC OUT-COND MEAS(NEW) + MEA-CND(CAMERA2) FINAL NUM. CALC FINAL OUTPUT COND OBJ-TYPE I/O SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP The "EVALUAT COND"(evaluation conditions) screen will appear. For details about the evaluation conditions, see page 3-18. EVALUAT COND SCREEN COND SAVE EDIT SEL 1REGISTER NO. 2CONDITION SET 3NUMBER OF OBJ 4DTECT NUMBER 5MATCH LVL 6GRAY LVL X COORD. Y COORD. 7TEST 0COND.1 AUTO(–10%) 000~128 000~(0~000) -10000~+1000 000.0~255.0 [TEST RESULT] [OUTPUT] K= NO M0= NO G0= NO X0= Y0= EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ) SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC 13-7 F C1 BRT 13