Download Worcester 35CDi Mk I Technical data
Transcript
Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. Installation Regulations .............................................. Page Introduction.................................................................. Page Technical Data .............................................................. Page Siting the Appliance .................................................... Page Flue Terminal Position ................................................ Page Air Supply .................................................................... Page Sealed System .............................................................. Page Domestic Hot Water .................................................. Page Gas supply .................................................................... Page 10. 11. 12. 13. 14. 15. 16. 17. 18. 2 2 4 6 6 7 7 8 8 Electrical........................................................................ Page 8 Installation.................................................................... Page 13 Commissioning ............................................................ Page 17 User information.......................................................... Page 19 Inspection and Servicing ............................................ Page 19 Replacement of Parts .................................................. Page 20 Short Parts List ............................................................ Page 26 Operational Flow Diagrams........................................ Page 27 Fault Finding ................................................................ Page 29 1. Installation Regulations 2. Introduction 1.1 Gas Safety (Installation & Use) Regulations 1994 (Amended 1996) : It is the law that all gas appliances are installed by a competent person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. It is in your interest, and that of safety, to ensure compliance with the law. 1.2 The manufacturers notes must not be taken, in any way, as overriding statutory obligations. 1.3 The compliance with a British Standard or European Norm does not, of itself, confer immunity from legal obligations. 1.4 The installation of the appliance must be in accordance with the relevant requirements of the Gas Safety Regulations, current IEE Regulations, Building Regulations, Building Standards (Scotland) and local water bye-laws. 1.5 The installation should follow the recommendations of the following British Standards unless otherwise indicated: BS6798 - Specification for the installation of gas fired hot water boilers of rated input not exceeding 60kW (Gross). BS5449 - Central heating for domestic premises. BS5546:1 - Installation of gas hot water supplies for domestic purposes. BS5440:1 - Flues and ventilation for gas appliances of rated input not exceeding 60kW (Gross): Flues. BS5440:2 - Flues and ventilation for gas appliances of rated input not greater than 60kW (Gross): Air supply. BS 5482 - Domestic butane and propane gas burning installations permanent dwellings. BS6891 - Installation of low pressure gas pipework installations upto 28mm (R1). BS6700 - Domestic water supply in buildings. BS7593 - Water treatment in domestic heating systems. 1.6. To ensure that the installation will perform to the highest standards, the system and components should conform to any other relevant standards. 1.7. The appliance and/or components conform, where applicable, with the Essential Requirements of the Gas Appliance Directive, the Boiler Efficiency Directive, the EMC Directive and the Low Voltage Directive. 1.8. In accordance with the requirements of COSSH the appliance does not contain any substances which are harmful to health. 1.9. Product Liability regulations indicate that, in certain circumstances, the installer can be held responsible, not only for mistakes on his part but also for damage resulting from the use of faulty materials. We advise that, to avoid any risk, only quality approved branded fittings are used. 1.10. LPG Installation. The appliance shall not be installed in a room or internal space below ground level when it is intended for use with LPG. This does not preclude the installation into rooms which are basements with respect to one side of the building but open to the ground on the opposite side. 1.11. The advice and instructions given in this document covers, as far as possible, the forseeable situations which may arise. Contact Worcester Heat Systems Technical Department, Telephone: 0990 266241, for advice on specific installations. The Benchmark initiative is the new code of practice to encourage the correct installation, commissioning and servicing of domestic central heating boilers and system equipment. The 'Log-book' is a vital document that must be completed by the installer at the time of installation. It confirms that the boiler has been installed and commissioned according to the manufacturers instructions. Without the completion of the Log-book, manufacturers may refuse to respond to a call-out from a householder, who will be advised that he or she must call back the installer, who has not fulfilled his obligations to record the information required by the initiative. It is important that: The services and the system are properly flushed as specified. The User is clearly instructed on the correct operation of the appliance. The benefits of regular servicing are explained - to maintain the efficiency and extend the life of the appliance. 2.1. General Information 2.1.1. The appliance is set to give a maximum output of 35.17kW to the domestic hot water and 25kW to the heating system. The hot water flow rate is limited to a nominal 12.6 l/min at a maximum temperature rise of 40°C. 2.1.2. The sanitary water section of the 3 appliance is suitable for water mains pressures of upto 10bar. 3 2.1.3. Conversion kits are available to convert the appliance from Natural Gas to Propane operation and vice versa. The kits include conversion instructions. 2.2 Electrical Supply 2.2.1. 230V ~ 50Hz. Load 180 watts. External fuse 3A, Internal fuses F1 - 2A, F2 - 1.25A (20mm). 2.3 Gas Supply 2.3.1. The appliance requires 4.12m /h of natural gas (G20) or 1.64m /h of propane (G31). 2.3.2. The meter or regulator should deliver 20mbar (G20) or 37mbar (G31) at the appliance, which is equivalent to about 18.5mbar or 35.5mbar at the gas valve inlet pressure test point. 2.4 Installation 2.4.1. The appliance is suitable for indoor installation only. 2.4.2. The appliance is for use with a sealed system only. 2.4.3. The clearances specified for servicing must not be reduced. 2.4.4. Do not place anything on top of the appliance . 2.4.5. It is a room sealed appliance and a separate combustion air supply is not required in any room or compartment in which the appliance is fitted. 2.4.6. If the appliance is fitted in a cupboard or a compartment is built around it after installation, then the structure must conform with the requirements of BS6798. However, because of the low casing losses, there is no need for the cooling ventilation openings in the compartment. The spaces specified for servicing must be maintained. 2.4.7. There is space for the service pipes to pass at the back of the appliance. 2