Download EverFocus ECMD200 Specifications
Transcript
5. Pulse Control: Position 1: Set to "ONCE" for instant reaction when PIR Once or twice detects movement, the connected device/alarm will be triggered immediately. Position 2: Triggering will start after the PIR detects movement twice within 15 seconds. PULSE 1 2 4 PINS 2 PAIRS w/Jumper connector 6. Terminals: N.C N.C: Normally closed N.O -- + N.O: Normally open contacts Input power (see below) Relay output current: 2A 24VAC, 2A 24VDC 7. Power: 12V DC Standby current: 1mA Working current: 25mA 8. Caution: Do not place in direct sunlight or reflected sunlight. Jumpers and wiring terminals of PIR Detector: OUTPUT TERMINALS N.C N.O -- + PULSE COUNT JP2 PULSE 1 2 J2 LED SELECTOR LIGHT CONTROL RECORDING CONTROL TIME J1 ADJUSTMENT VR2 J4 VR1 8