Download ACME IE-200 Specifications
Transcript
Water Pressure Reducing Valves Applications • • • • • • • X Ref Typical Installation Accessories Options The model 500 is the workhorse of the Wilkins pressure reducing valve line up. The model 500 exhibits the highest flow rates of the entire Wilkins regulator line, making it most suitable for commercial, industrial, and irrigation applications that demand high flow rates with minimal fall-off. The model 500 is available in 10 – 35 psi, 25 – 75 psi, 75 – 125 psi, and 10 – 125 psi adjustment ranges. All 1/2” to 2” 500’s are equipped with a union inlet and female NPT outlet, while the 21/2” and 3” are provided with female NPT on the inlet and outlet. Features 500 Series 1/2”, 3/4”, 1”, 11/4”, 11/2”, 2”, 21/2”, 3” Pressure rated 300 psi Spring range 25 to 75 psi; factory set at 50 psi Field set 21/2” – 3” Maximum temperature 180°F All bronze body and bell housing provides durability and long life Built-in by-pass prevents buildup of excessive system pressure caused by thermal expansion (1/2” – 2”) • Nylon reinforced Buna-N diaphragm • Balanced piston design • May be installed in any position • All internal parts corrosion-resistant • Serviceable in-line • Available tapped and plugged for gauge (optional) • Available tapped with gauge (optional) • Available with BSP threads 1/2” through 2” (optional) •ASSE® Listed 1003 (1/2"-21/2"), IAPMO® Listed (1/2"-2"), CSA® Certified (1/2"-2"), City of Los Angeles (1/2"-3") Model 500 Union end connection standard and available 1/2” through 2” in FNPT Model 500LPC Spring range is 10-35 psi, factory set at 20 psi. Model 500SW Chrome plated internals for salt water Model 500C Union end connection, 1/2” through 2” female copper sweat Model 510 Model 500HR Spring range is 75-125 psi, factory set at 85 psi; field set 21/2” – 3” Rated for 400 psi and spring range is 75 - 125 psi, factory set at 85 psi; field set 21/2” – 3” Model 500SC Model 500HLR Spring range is 10-125 psi, factory set at 50 psi; field set 21/2” – 3” Sealed cage bell and stainless steel adjusting screw. For below-ground and indoor applications Model 500HT For high temperature application, up to 210°F. Model 500XL California AB 1953 compliant Model 500L Less built-in by-pass. (1/2” – 2”) Model 500LPV Same as 500HT except spring range is 10-35 psi, factory set at 20 psi For Additional Information, including flow curves, reference WK-RC catalog or visit our web site. Pressure gauges (Model 92-25A 1/2", 3/4") (Model 92-25 1" – 3") Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient clearance for testing & maintenance. The Model 500 may be installed in any position. If installed in a pit, vault, or indoors, specify the “SC” sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (ie: 200 psi inlet reduced to 50 psi outlet). CAUTION: Anytime a reducing vale is adjusted, a pressure gauge (Model HGI-25) must be used downstream to verify correct pressure setting. Do not bottom out adjustment bolt on bell housing. WILKINS 500 500HR WATTS 223, N223B 223HP, N223BHP CONBRACO 36H Tech Support: 855-ONE-ZURN www.zurn.com 8