Download VDC Electronics BatteryMINDer 36271 Instruction manual
Transcript
BatteryMINDer® Model 36271 The chart below shows the need to regulate the output voltage of the charger to ensure against over or under charging your battery over a wide range of temperatures. Using your At-the-Battery Sensor will accomplish this better than any other known method. Temperature Ranges Charge Voltage GEL / Flooded / AGM >=120°F / >=49°C 40.5 / 41.4 / 42.0 38.4 ±0.35 Vdc 110-120°F / 43-49°C 40.8 / 41.7 / 42.3 38.7 ±0.35 Vdc 100-110°F / 38-43°C 41.1 / 42.0 / 42.6 39.0 ±0.35 Vdc 90-100°F / 32-38°C 41.4 / 42.3 / 42.9 39.3 ±0.35 Vdc 80-90°F / 27-32°C 42.0 / 42.9 / 43.5 39.6 ±0.35 Vdc 70-80°F / 21-27°C 42.3 / 43.2 / 43.8 40.2 ±0.35 Vdc 60-70°F / 16-21°C 42.9 / 43.8 / 44.4 40.8 ±0.35 Vdc 50-60°F / 10-16°C 43.2 / 44.1 / 44.7 41.1 ±0.35 Vdc 40-50°F / 4-10°C 44.1 / 45.0 / 45.6 42.0 ±0.35 Vdc <=40°F / <=4°C 44.4 / 45.3 / 46.2 42.3 ±0.35 Vdc Rev. D-111510 Page 23 Maintenance - Float Voltage P/N VDC36271-MNL