Download Dimplex LA 22PS Operating instructions
Transcript
11 1 Type and order code 2 Design 2.1 Degree of protection according to EN 60 529 for compact devices and heating components 2.2 Installation Location 3 Performance data 3.1 Operating temperature limits: 3.2 3.3 Heating water flow/return flow 1 °C / °C Air °C Temperature spread of heating water at A7 / W35 Heat output / COP at A-7 / W35 2 at A-7 / W45 2 kW / --- kW / --- LA 17PS LA 22PS LA 26PS IP 24 IP 24 IP 24 Outdoors Outdoors Outdoors Up to 65 / above 18 Up to 65 / above 18 Up to 65 / above 18 -20 to +35 -20 to +35 -20 to +35 9.3 5.0 9.5 5.0 9.4 5.0 3 6.7 / 2.5 6.4 / 2.4 7.7 / 2.4 7.5 / 2.3 8.7 / 2.4 8.4 / 2.2 4 11.4 / 2.6 10.8 / 2.5 13.6 / 2.6 13.1 / 2.5 14.4 / 2.6 13.9 / 2.5 3 6.0 / 2.2 4 at A2 / W35 2 kW / --- at A7 / W35 2 at A7 / W45 kW / --- 2 at A10 / W35 kW / --- 2 kW / --- 3.4 Sound power level dB(A) 3.5 Sound pressure level at a distance of 10 m (air outlet side) dB(A) Heating water flow with an internal pressure differential of m³/h / Pa 3.7 Air flow rate m³/h 3.8 Refrigerant; total filling weight type / kg 3.6 4 Dimensions, connections and weight 4.1 Device dimensions H x W x L cm 4.2 Device connections to heating system Inch 4.3 Weight of the transportable unit(s) incl. packing kg 5 Electrical connection 5.1 Nominal voltage; fuse protection 5.2 Nominal power consumption 2 5.3 Starting current with soft starter A 5.4 Nominal current A2 W35 / cos ϕ A / --- 5.5 max. power consumption of compressor protection (per compressor) W 6 V/A A2 W35 kW Complies with the European safety regulations 7 Additional model features 7.1 Defrosting Type of defrosting Defrosting tray included 7.2 Heating water in device protected against icing 6 7.3 Performance levels 7.4 Controller internal/external 7.0 / 2.2 10.3 / 2.2 7.8 / 2.3 12.5 / 2.3 13.3 / 2.3 3 8.7 / 3.2 8.3 / 3.0 4 14.5 / 3.1 14.3 / 3.0 16.7 / 3.1 16.5 / 3.0 18.8 / 3.1 18.6 / 3.0 3 10.1 / 3.6 9.6 / 3.4 12.6 / 3.8 12.0 / 3.6 13.7 / 3.6 13.3 / 3.5 4 17.3 / 3.5 16.6 / 3.4 22.0 / 3.8 21.1 / 3.5 24.0 / 3.7 22.9 / 3.5 10.6 / 3.1 10.5 / 3.0 11.7 / 3.1 11.5 / 3.0 3 9.3 / 2.9 11.3 / 3.0 12.5 / 2.9 4 16.1 / 2.9 20.5 / 3.0 21.6 / 3.0 3 11.8 / 4.1 11.4 / 4.1 13.7 / 4.2 13.5 / 4.1 15.0 / 4.1 14.7 / 4.0 4 19.6 / 3.8 19.2 / 3.8 23.4 / 4.0 23.2 / 3.9 26.2 / 4.0 25.9 / 4.0 64 68 68 37 41 41 1.6 / 2900 3.0 / 10000 2.0 / 4500 3.5 / 13800 2.2 / 3100 3.8 / 8900 5500 8000 8000 R290 / 1.8 R290 / 2.2 R290 / 2.5 157 x 155 x 85 171 x 168 x 100 171 x 168 x 100 G 1 1/4'' external G 1 1/4'' external G 1 1/4'' external 330 360 371 400 / 20 T 4.74 4.76 400 / 20 T 5.4 5.5 23 8.6 / 0.8 400 / 25 T 6.1 6.2 25 8.6 / 0.8 9.8 / 0.8 30 9.9 / 0.8 11.1 / 0.8 11.2 / 0.8 35 5 5 5 Automatic Automatic Automatic Hot gas Hot gas Hot gas Yes (heated) Yes (heated) Yes (heated) Yes Yes Yes 2 2 2 External External External 1. See operating limits diagram 2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature and 55 °C heating water flow temperature. 3. Operation with 1 compressors 4. Operation with 2 compressors 5. See CE declaration of conformity 6. The heat circulating pump and the heat pump controller must always be ready for operation. www.dimplex.de EN-9 English 11 Device Information