Download Dimplex LA 22PS Operating instructions

Transcript
11
1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
3.2
3.3
Heating water flow/return flow 1
°C / °C
Air
°C
Temperature spread
of heating water
at A7 / W35
Heat output / COP
at A-7 / W35 2
at A-7 / W45 2
kW / ---
kW / ---
LA 17PS
LA 22PS
LA 26PS
IP 24
IP 24
IP 24
Outdoors
Outdoors
Outdoors
Up to 65 / above 18
Up to 65 / above 18
Up to 65 / above 18
-20 to +35
-20 to +35
-20 to +35
9.3
5.0
9.5
5.0
9.4
5.0
3
6.7 / 2.5
6.4 / 2.4
7.7 / 2.4
7.5 / 2.3
8.7 / 2.4
8.4 / 2.2
4
11.4 / 2.6
10.8 / 2.5
13.6 / 2.6
13.1 / 2.5
14.4 / 2.6
13.9 / 2.5
3
6.0 / 2.2
4
at A2 / W35 2
kW / ---
at A7 / W35 2
at A7 / W45
kW / ---
2
at A10 / W35
kW / ---
2
kW / ---
3.4
Sound power level
dB(A)
3.5
Sound pressure level at a distance of 10 m
(air outlet side)
dB(A)
Heating water flow
with an internal pressure differential of
m³/h / Pa
3.7
Air flow rate
m³/h
3.8
Refrigerant; total filling weight
type / kg
3.6
4
Dimensions, connections and weight
4.1
Device dimensions
H x W x L cm
4.2
Device connections to heating system
Inch
4.3
Weight of the transportable unit(s) incl. packing
kg
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption 2
5.3
Starting current with soft starter
A
5.4
Nominal current A2 W35 / cos ϕ
A / ---
5.5
max. power consumption of compressor protection
(per compressor)
W
6
V/A
A2 W35
kW
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing 6
7.3
Performance levels
7.4
Controller internal/external
7.0 / 2.2
10.3 / 2.2
7.8 / 2.3
12.5 / 2.3
13.3 / 2.3
3
8.7 / 3.2
8.3 / 3.0
4
14.5 / 3.1
14.3 / 3.0
16.7 / 3.1
16.5 / 3.0
18.8 / 3.1
18.6 / 3.0
3
10.1 / 3.6
9.6 / 3.4
12.6 / 3.8
12.0 / 3.6
13.7 / 3.6
13.3 / 3.5
4
17.3 / 3.5
16.6 / 3.4
22.0 / 3.8
21.1 / 3.5
24.0 / 3.7
22.9 / 3.5
10.6 / 3.1
10.5 / 3.0
11.7 / 3.1
11.5 / 3.0
3
9.3 / 2.9
11.3 / 3.0
12.5 / 2.9
4
16.1 / 2.9
20.5 / 3.0
21.6 / 3.0
3
11.8 / 4.1
11.4 / 4.1
13.7 / 4.2
13.5 / 4.1
15.0 / 4.1
14.7 / 4.0
4
19.6 / 3.8
19.2 / 3.8
23.4 / 4.0
23.2 / 3.9
26.2 / 4.0
25.9 / 4.0
64
68
68
37
41
41
1.6 / 2900 3.0 / 10000 2.0 / 4500 3.5 / 13800 2.2 / 3100 3.8 / 8900
5500
8000
8000
R290 / 1.8
R290 / 2.2
R290 / 2.5
157 x 155 x 85
171 x 168 x 100
171 x 168 x 100
G 1 1/4'' external
G 1 1/4'' external
G 1 1/4'' external
330
360
371
400 / 20 T
4.74
4.76
400 / 20 T
5.4
5.5
23
8.6 / 0.8
400 / 25 T
6.1
6.2
25
8.6 / 0.8
9.8 / 0.8
30
9.9 / 0.8
11.1 / 0.8
11.2 / 0.8
35
5
5
5
Automatic
Automatic
Automatic
Hot gas
Hot gas
Hot gas
Yes (heated)
Yes (heated)
Yes (heated)
Yes
Yes
Yes
2
2
2
External
External
External
1. See operating limits diagram
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
3. Operation with 1 compressors
4. Operation with 2 compressors
5. See CE declaration of conformity
6. The heat circulating pump and the heat pump controller must always be ready for operation.
www.dimplex.de
EN-9
English
11 Device Information