Download Bosch 4306 Technical data
Transcript
7. Dimensional data 7.3. Dimensions: DLT 3-phase AC isolation transformer A C1 B1 G1 B A Hø E F D G C Hø E F D Standing version for foot mount type DLT.../S Example: rating plate Type: Diagram: Bj. DLT 2,5/S/380/415/440-220 1993 Prim.: 380-400/415/440 V Sec.: 220-230V S 2,5 kVA Horizontal version for wall mount type DLT.../L Yyn0 1U1, 1V1, 1W1 1U2, 1V2, 1W2 1U3, 1V3, 1W3 2U1, 2V1, 2W1 T 40/B f 440 V 415 V 380 V–400 V 220 V–230 V 50/60 Hz 1U1 1U2 1U3 1V1 1V2 1V3 1W1 1W2 1W3 2U1 a 2V1 2W1 2N1 1) b 1) Maximum load: DC 24 V/1 A; AC 230 V/1 A Dimensions and technical data for threephase isolation transformer with Usec = 220-230 V; Upri = 380-400 V, 415 V, 440 V, 460 V, 500 V, f = 50/60 Hz Dimensions in mm A B B1 C C1 D E F G G1 H power loss in W 180 180 205 205 240 240 240 240 300 300 300 300 335 335 360 360 360 360 420 420 580 660 660 190 190 210 210 260 260 260 260 325 325 325 325 365 365 395 395 395 395 450 450 540 590 655 205 205 235 235 270 270 270 270 340 340 340 340 380 380 400 400 400 400 105 105 130 130 140 140 150 150 140 140 165 165 175 175 190 190 205 205 245 275 255 295 305 100 100 120 120 155 155 165 165 165 165 195 195 210 210 215 215 230 230 150 150 170 170 200 200 200 200 250 250 250 250 280 280 300 300 300 300 350 400 –– –– –– 80 80 95 95 110 110 110 110 140 140 140 140 160 160 170 170 170 170 190 190 270 270 270 125 125 145 145 170 170 170 170 210 210 210 210 230 230 250 250 250 250 280 280 400 480 480 75 75 95 95 110 110 120 120 110 110 135 135 145 145 160 160 175 175 195 225 205 245 255 185 185 209 209 240 240 240 240 310 310 310 310 350 350 370 370 370 370 7 7 7 7 11 11 11 11 11 11 11 11 11 11 11 11 11 11 16 16 18 18 18 65 70 120 140 155 165 180 195 220 235 240 265 300 350 375 395 500 510 600 800 875 1000 1170 Type DLT 0.5/ • /380/415/440–220 0.5/ • /380/460/500–220 1.0/ • /380/415/440–220 1.0/ • /380/460/500–220 1.5/ • /380/415/440–220 1.5/ • /380/460/500–220 2.0/ • /380/415/440–220 2.0/ • /380/460/500–220 2.5/ • /380/415/440–220 2.5/ • /380/460/500–220 4.0/ • /380/415/440–220 4.0/ • /380/460/500–220 5.0/ • /380/415/440–220 5.0/ • /380/460/500–220 7.5/ • /380/415/440–220 7.5/ • /380/460/500–220 10/ • /380/415/440–220 10/ • /380/460/500–220 15/ • /380–220 20/ • /380–220 25/ • /380–220 35/ • /380–220 50/ • /380–220 max. conn. Wgt. diameter in kg in mm2 4 4 4 4 4 4 4 4 4 4 10 10 10 10 10 10 10 10 16 35 35 70 70 8.5 8.5 13 13 21 21 24.5 24.5 30.5 30.5 42 42 55 55 70 70 85 85 122 152 180 275 320 MBDLT Figure 7.3: Dimensional data of the DLT threephase AC isolation transformer • DOK-POWER*-KDV*2.3****-ANW1-EN-E1,44 • 06.97 46