Download Compaq ProLiant ML350p Specifications
Transcript
3-10 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 174Configuration/Slot Mismatch Device Not Found None EISA or PCI board not found. Run the server setup utility and correct. 175Configuration/Slot Mismatch Device Found None EISA or PCI board added, configuration not updated. Run the server setup utility and correct. 177-Configuration Not Complete None Incomplete System Configuration detected. Run the server setup utility and correct. 178-Processor Configuration Invalid None Processor type or step does not match configuration memory. Run the server setup utility and correct. 180-Log Reinitialized None The IML has been reinitialized, probably due to corruption of the log. Event message, no action required. 201-Memory Error None RAM failure detected. Run Diagnostics. Replace failed assembly as indicated. 202-Memory Type Mismatch 2 short An incompatible memory module is installed in the system. Compare Compaq part numbers from installed memory modules with the manual. If not listed, the memory modules are incompatible and should be replaced or removed. 203-Memory Address Error None RAM failure detected. Run Diagnostics. Replace failed assembly as indicated. 207-ECC Corrected Single Bit Errors in DIMM in Memory Module Socket 2 short A memory module is malfunctioning. Run Diagnostics. Replace or remove malfunctioning memory module as indicated. continued