GAS SUPPLY PIPING ! CAUTION ! WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. Fire Hazard. Do not use matches, candles, open flames, or other methods providing ignition source. Failure to comply will result in death or serious injury. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. Leak Check Gas Piping Pressure test boiler and gas connection before placing boiler in operation. • Disconnect boiler and its individual gas shutoff valve from gas supply system. Check Gas Supply • Isolate boiler from gas supply system by closing manual gas shutoff valve. See Figure 19, Page 29. Gas pipe to your boiler must be correct size for length of run and for total Btu per hour input of all gas utilization equipment connected to it. See Table 7, Page 29. Boiler and its individual shutoff valve must be disconnected from gas supply piping system during any system pressure testing at test pressures in excess of ½ psig (3.5kpa). Boiler must be isolated from gas supply piping system by closing its individual manual shutoff valve during any pressure testing of gas supply piping system at test pressures equal to or less than ½ psig (3.50ka). • Locate leakage using gas detector, noncorrosive detection fluid, or other leak detection method acceptable to authority having jurisdiction. Do not use matches, candles, open flames, or other methods providing ignition source. • Correct leaks immediately and retest. Table 6 - Gas Supply Pressure Connecting The Gas Piping See Figure 19, Page 29 for general layout at boiler. Gas line enters boiler from right side jacket panel. Boiler is equipped with ½” NPT connection on gas valve for supply piping. Following rules apply: 1. Use piping materials and joining methods acceptable to authority having jurisdiction. In absence of such requirements: • USA - National Fuel Gas Code, ANSI Z223.1/NFPA 54 MAXIMUM GAS SUPPLY PRESSURE MINIMUM GAS SUPPLY PRESSURE • Canada - Natural Gas and Propane Installation Code, CAN/CSA B149.1 2. Size and install gas piping system to provide sufficient 3. 4. 5. 6. 7. 8. 9. 10. DANGER gas supply to meet maximum input at not less than minimum supply pressure. See Table 7, Page 29 Use ground joint unions. Provide sediment trap up stream of gas valve. Use two pipe wrenches when making the connection to gas valve to keep it from turning. Install a manual shutoff valve in the vertical pipe about 5 feet above floor. Tighten all joints securely. Propane gas connections should only be made by licensed propane installer. Two stage regulation should be used by propane installer. Propane gas piping should be checked out by propane installer. 28 NATURAL GAS PROPANE GAS 10” w.c. 14” w.c. 4” w.c. 10” w.c.