Download Arrow VM1012-B Specifications
Transcript
4-8 OPERATION CHAPTER 4 ONLY WITH HUMIDITY AND TEMPERATURE OPTION “00h 1Eh” displaying temperature in Celsius. It needs 6 characters. “00h 1Fh” displaying temperature in Farenhait. It needs 6 characters. “00h 21h” displaying relative humidity. It needs 2 characters. The date and time can be displayed from any place in the Text. It takes characters of variables. The amount of characters reserved for variables can just take 16 characters per line. Example: DISPLAY Num. = 2 Text line 1 = “LARTET” Text line 2 = “123456” Transmission block: 00h 02h 02h 18h 00h 1Bh 06h 4Ch 41h 52h 54h 45h 54h 00h 14h 02h 31h 32h 33h 34h 35h 36h 00h 0Dh 66h 67h 00h 03h 00h 02h 02h 18h 00h 1Bh 06h 4Ch 41h 52h 54h 45h 54h 00h 14h 02h 31h 32h 33h 34h 35h 36h 00h 0Dh 66h 67h 00h 03h Start. Display num. 2 Number of bytes in hexadecimal. (24 decimal) Beginning a message. It points to the number of line 1 Text “LARTET” in ASCII characters It points to the number of line 2 Text “123456” in ASCII characters It indicates end of data. CRC End of block. DT-203X, DT-105X and DT-110X display series