Transcript
Enterprise Buildings Integrator™ HMIWeb Client Browser Station Open System Integration – EBI supports multiple industry standard communication protocols to allow enterprise-wide monitoring and control from a single client workstation. Honeywell Enterprise Buildings Integrator™ An integrated facility management solution. PRODUCT FEATURES: • • • • • • • PRODUCT FEATURES: PRODUCT FEATURES: The complete solution for the safety and comfort of your people and the effective operation of your buildings Provides an “enterprise view” that goes beyond traditional building automation, fire, and security systems Fully UL listed to provide authorized operators with 2-way command/control of any subsystem from any listed station Allows full interaction between applications to minimize risk to personnel and assets, maximize personnel productivity, and optimize system and equipment efficiency Operator segregation allowing access only to data and information appropriate for the specific user Fully scalable from a single application and controller, to enterprise integration with multiple applications and servers distributed across the Ethernet LAN and WAN Migration platform for a wide range of Honeywell legacy products including Excel Building Supervisor (XBS), Excel Building Supervisor Integrated (XBSi), DeltaNet Excel Plus, MicroCel, MacroCel, Excel Classic, FS90/FS90 Plus, Delta 1000 and Delta 2000 • Harnessing the power of Honeywell’s patented Distributed System Architecture (DSA), EBI lets you achieve this convenient and seamless single operator interface without complex engineering, database management or sharing • Reduces training, maintenance and administration costs by employing the same tools for creating graphic displays (for building systems and process control), configuring points and all system configurations • Supports implementation of occupational health and safety polices • More effectively leverages your systems investment • Client and server support for BACnet, LonWorks, OPC, Modbus, and Advanced DDE • BACnet and OPC discovery mechanisms to simplify engineering and configuration APPLICATIONS: Honeywell EBI is approved for use in the following categories: • UL 864 – UOJZ Proprietary Protective Signaling System – UOXX Control Unit Accessories – UUKL Smoke Control Systems – UDTZ Signal System Units • UL 916 – PAZX Energy Management Equipment • UL 1610 – AMCX Central Station Receiving Unit • UL 294 – ALVY Access Control System Units • UL 1076 – APOU Proprietary Alarm Receiving Units • UL 2017 – QVAX Process Management Equipment • UL 60951 – NWGQ Information Technology Equipment APPLICATIONS: • Enterprise-wide, Integrated sequences of operation allow events in one subsystem to automatically and directly trigger events in another system. Example: – Tenant activates Fire Alarm pull station – EBI initiates digital video recording and captures the pre-recorded video leading up to the event – Doors are unlocked allowing safe egress while presenting live video to maintain facility security – HVAC initiates proper fan pressurization control for smoke control system operation – Instruction pages and system information is presented to the various operators to manage risk and follow proper emergency procedures • Emergency and routine situations handled with maximum efficiency by bringing the right information together at the correct decision point • • • • • Monitoring and control of third-party HVAC central plant and unitary equipment, industrial controls, and other systems utilizing Open System Communication Protocols • Monitoring third-party Life Safety systems • Integrated system sequences of operation • History collection, trending, and global scheduling of third-party open systems EBI Server and Redundancy Option Applicable for use in UL2050, DoD, DCID, and SCIF high-security applications Approved by ULC for similar applications in Canada Approved by the California State Fire Marshal, NYC/MEA, and additional international agencies See individual product specification data sheets for specific approvals Go to: www.honeywell.com/ebi for additional information regarding our powerful software applications. • Microsoft Windows 2000, SQL (or MSDE) platform • Remote access server (RAS) supported (see EBI Compatibility Matrix for more information) Server PC Specifications (Standard Performance): • Dell, Pentium 4, 1.7 GHz, 1 GB RAM, 40 GB HD min. • Terminal services support for remote access via PDA or other handheld device • Alarm pager capability for off-site notification including e-mail and SNMP support • Diagnostic tools with remote access capabilities • Quality assurance: ISO 9001, SEI Level 3 W7054A UL Listed EBI Server • Client/Server Interface, Cimetrics BACstac • BACnet Ethernet & IP Support • RPM, WRP, COV, BBMD support (See EBI PICs for more information) • Static and rotary station licensing • HMIWeb client and IE browser support • 40 simultaneous clients supported – Operator area segregation and permissions enforced • Multi-Monitor support on single client license • Operator definable alarm and event summaries • Windows 2000 or Windows XP • Read/write of analog and status points • Item names up to 64 characters LonWorks® Network • • • • • Integrates and controls a plant’s HVAC, lighting, hydraulics and energy usage • Provides primary monitoring and control of plant’s life safety systems with integrated response prompting and tracking capabilities, for exceptional incident management and regulatory compliance • Integrated access control provides site mustering capabilities to automatically track employees during emergency evacuation situations • Video surveillance and digital video management support permits control room observation of critical processes for informed operational and safety decisions PRODUCT FEATURES: Intranet and Internet Access Connectivity options allow access from anywhere in the world via HMIWeb Client and Browser Stations, or Web page access via Web Toolkit and Web Point Control optional interfaces. PRODUCT FEATURES: PRODUCT FEATURES: • PeopleSoft and SAP Integration to EBI Cardholder Management System (CMS) database for database synchronization periodically or on demand • Generic Cardholder Object Model (CHOM) database integration interface option • Open Database Connectivity (ODBC) support allows read-only access to EBI point, history, and event data for third-party system analysis and reporting • • • • • HMIWeb browser station utilizing Microsoft Internet Explorer (IE) provides full client access with operator permissions and area segregation enforced • EBI systems with TCP/IP network access and the network server option may also utilize Web Toolkit pages with Active X controls for analog and status point monitoring and control • Web Point Control utilizes Java Applets to allow status point control and allow users to define schedules up to one week in advance Integrate multiple servers each performing a different application: HVAC, Security, Life Safety, Industrial Control DSA for points and DSA for cardholders allows Operator Client Stations consistent access to both local and remote points and cardholder data Extends the capacity of a single server solution to support additional points, channels, and controllers Utilizes Windows 2000 Server APPLICATIONS: APPLICATIONS: • The HVAC system and security system operate independently, and share data to optimize occupancy scheduling, lighting, and energy management strategies based on information from both systems • Cardholder data may be managed from a single client on a single server in a “Traveling Card” concept allowing cardholders to move between sites • Changes made to personnel information in the HR database are automatically sent to the EBI CMS to update area and equipment access information • Events in the EBI CMS sends information to the HR system for time and attendance or after-hours billing reporting for energy and services Internet Explorer Web Toolkit Network Firewall APPLICATIONS: • Users away from the office may access their EBI system using VPN, or through a thin client access over the internet to check system status, issue commands, respond to alarms, or request reports EBI DSA Server EBI DSA Server Experion Process Knowledge System (PKS)™ ANSI/EIA Std. 709.1 LonWorks Network Services (LNS) Connectivity via: PCLTA, i.LON® 600/1000 EXCEL 5000 Open LON and Excel CARE (see 63-9026 for more information) EBI Web Point Control Global HRMS & PeopleTools support Interface to SAP R/3 Human Resources Module ODBC Network Firewall Network Firewall • Point monitoring and control 74-3487 Specification Data • Ethernet and T1 interfaces • AES network encryption capable Distributed System Architecture (DSA) Provides centralized monitoring for geographically distributed systems, and scalability for large enterprise systems. Enterprise Systems Integration Share information with personnel, office and financial system databases. Advanced Dynamic Data Exchange (AdvDDE) and DDE Network Router/Firewall-14507744 Series Specification Data 74-3201 • Single or dual Intel Xeon processors at up to 3.2 Ghz clock speed • 12 GB SDRAM (max) • 584GB Internal HD storage (max) • 10/100/1000 Gigabit on-board Ethernet • Embedded SCSI and RAID controllers • CD/CDR/DVD and tape backup options APPLICATIONS: OLE for Process Control (OPC) BACnet, ASHRAE STD, SSPC 135-2001 EBI HMIWeb Client Stations Experion Process Knowledge System™ (PKS)™ Integration – Unlocks benefits via a unified, collaborative and open architecture that integrates seamlessly to deliver a single operator environment for plant control, life safety, HVAC, digital video and security. Modbus: Gould, Modbus Plus, Universal Modbus Corporate Intranet, VPN, or WAN • Gould Modbus to Modicon 584 and 984 PLCs • RS232 serial interface and Modbus TCP support Wide Area Network/Internet (WAN) Local Area Network (LAN) Redundant Router (Optional) Primary Ethernet Network Excel Life Safety System – XLS2000 A High-Performance Life-Safety Solution 74-2942 Specification Data 74-2953 Specification Data • Pressure-independent or pressure-dependent VAV box control • Single-duct/dual-duct VAV box control solutions • Reheat and peripheral radiation control (selectable "first on" sequencing) • Series/parallel fan • Supply/return air tracking • LonMark functional profile 8010 W7751H Inputs • 1T7770 wall module • 1 resistive input • 1 voltage input • 1 bypass button input Outputs • 4 triac outputs • 1 LED output • Integrated actuator OmniProx™ OP40 92995100063-B Specification Data P/N OP40HON • Mounts on single-gang electrical box • Typical read range: 4" • Wiegand output • Genuine HID™ compatible OmniSmart OS40 9299510082-A Specification Data P/N OS40HON • Contactless smart card reader APM Interface 74-2962 Specification Data • Space or return air temperature control • ASHRAE cycles 1, 2, 3 • 8 output for HVAC control • PWM or floating damper control • LonMark functional profile 8080 Inputs • 1 T7770 wall module • 2 resistive inputs • 2 voltage/current inputs • 4 dry contact digital inputs • 1 bypass button input Outputs • 8 triac outputs • 1 LED output D003 • Tracer T-BUSS interface for up to 128 supervised high commercial grade addressable point modules (APM). • 12 VDC operation. • Standard sized board to fit DIN rail mounting hardware. May also be fitted to D009 backplane. • Mounting holes for installation using standoffs. • Connection via plug-in screw terminal blocks. • Supports both input APMs (EL135) and output APMs (EL138). Output APMs allow relay output, or control points to be individually distributed throughout the field. • Up to 16 APM interface devices may be installed per system, allowing a possible 1024 APMs to be connected per system. • Switch selectable channel ID. • Switch selectable biasing and termination resistors for RS485 connection. • LED indication of IntelliBus polling, IntelliBus status, APM polling and APM channel tamper status. • Supervised IntelliBus interface. • Field upgradeable firmware. OmniProx™ OP45 92995100063-B Specification Data P/N OP45HON • Switch-plate size; mounts on a UK size electrical box • Typical read range: 3 – 4.5" • Wiegand output • Genuine HID™ compatible OmniProx™ OP90 DTMF ELM Interface D004 • For high security, Type 1 installation. • Used for retro-fitting existing XSMP Type 1 field infrastructure. • Support for up to 8 Type 1 DTMF ELMs (EL131) per interface. • 12 VDC operation. The DTMF ELMS also require an additional 48 VDC power supply. • Standard sized board to fit DIN rail mounting hardware. May also be fitted to D009 backplane. • Mounting holes for installation using standoffs. • Connection via plug-in screw terminal blocks. • Up to 16 DTMF ELM interface devices may be installed per system, allowing a possible 128 ELMs to be connected per system. • Switch selectable channel ID. • Switch selectable biasing and termination resistors for RS485 connection. • LED indication of IntelliBus polling and IntelliBus status. • Supervised IntelliBus interface with DES encryption. • Field upgradeable firmware. Fan Coil Unit Controller W7752 74-2959 Specification Data • 2 pipe, 4 pipe fan coil unit control • Up to 3 speed fan control • With or without electrical reheat • Space freeze protection • LonMark functional profile 8020 Inputs • 1 T7770 wall module • 1 dry contact digital input • 1 bypass button input Outputs • 3 relay outputs • 1 LED output • 1 electric heat relay (F type only) 92995100082-A Specification Data P/N OS10HON • Contactless smart card reader 92995100082-A Specification Data P/N OS30HON • Contactless smart card reader D014 • 16 character by 4 line backlit display. • Internal sounder. • Tamper protected enclosure. • 12 VDC operation. • Flexible, function key operated menu system. • Supervised IntelliBus interface with DES encryption. • Field upgradeable firmware. Unit Ventilator Controller W7753A OmniSmart OS10 92995100063-B Specification Data P/N OP90-FWS • Switch-plate size; mounts on a US size electrical box • Vandal-resistant cast zinc-alloy design • Typical read range: 2" • Wiegand output • Genuine HID™ compatible OmniProx™ OP95 P/N OP95-FWS • Switch-plate size; mounts on a US size electrical box • Vandal-resistant cast zinc-alloy design with piezo keypad • Typical read range: 2" • Wiegand output • Genuine HID™ compatible ELM Interface D005 • For high security, Type 1 installation. • RS485 interface for up to 32 Type end of line modules (D006) per device. • Automatic assignment of interface channel ID and ELM address. • 12 VDC operation. • Standard sized board to fit DIN rail mounting hardware. May also be fitted to D009 backplane. • Mounting holes for installation using standoffs. • Connection via plug-in screw terminal blocks. • Switch selectable biasing and termination resistors for RS485 connection. • LED indication of IntelliBus polling, IntelliBus status and ELM polling. • Supervised IntelliBus interface with DES encryption. • Field upgradeable firmware. Remote Input/Output Device W7761A 74-2698 Specification Data • Generic I/O for lighting, exhaust fans, pumps, and more LonMark standard objects for sensors and actuators Inputs • 4 resistive inputs • 2 voltage inputs • 4 dry contact digital inputs Outputs • 8 triac outputs Communicating Thermostat T7300F/Q7300H 63-1281 Specification Data • One thermostat model for either heat pump or conventional RTU • Up to three stages of heat and cool • Works with T7047 Remote Temperature Sensor • Proportional plus integral control eliminates temperature fluctuations • 7 day programming - 2 occupied / 2 unoccupied periods per day • Discharge air sensing capability with C7046C Sensor • Conforms to LonMark thermostat functional profile Relay Expansion Hydronic Controller W7762B/7763C 74-2934 Specification Data • Radiators, induction units, chilled ceilings and fan coil units with manual fan switching • High efficiency, low cost heat/cool valve application solution • Model with integrated or remote module for wall or unit mounted • LonMark functional profile 8020 8 dry contact, normally open or normally closed, relay outputs per expansion board. 30 VDC, 1.5 A relay contact rating. 12 VDC operation. Standard sized board to fit DIN rail mounting hardware. May also be fitted to D009 backplane. Mounting holes for installation using standoffs. Connection via plug-in screw terminal blocks. Up to 16 relay devices may be installed per system, allowing a possible 128 relay outputs per system. Switch selectable channel ID. Switch selectable biasing and termination resistors for RS485 connection. LED indication of IntelliBus polling, IntelliBus status and relay state. Supervised IntelliBus interface with DES encryption. Field upgradeable firmware. Resistor EOLM Interface Inputs • 1 space temperature sensor (either built in or via T7770 wall module) • 1 dry contact digital input Outputs • 1 relay output • 4 triac outputs D015 • Provision for 8, four state resistor network inputs per interface. • 12 VDC operation. • Supplied in two piece plastic enclosure. • Up to 11 interface devices may be installed per system, allowing for the connection of up to 88 resistor end of line modules to be connected per system. • Jumper selectable channel ID. *Tema Key – Proximity & HID Reader P/N TK_C02, TK_C03 HID Compatible • NEURON CHIP™ 3150 (Echelon) 32 KByte EPROM to download application firmware • LonWorks™(Echelon) connection to the TS_AC01 unit with a transfer rate of 78 kbps • Alphanumeric graphic liquid crystal display (LCD), back-lit, with two lines of 16 characters • Reader for proximity cards, HID with TK_C03, (standard ISO/ABA 125Khz, up to 5cm reading distance) • Numeric-function keyboard with 16 keys • 1 double-colored LED signal: green LED for the correct reading and red/yellow for invalid • Variable tones for valid/invalid transactions • Management of two dry contact digital inputs to control the door status • Management of two relay outputs (1A@30V) to command door unlock and signal external outputs • Tamper protection of the unit to prevent opening P/N TK_C01 • NEURON CHIP™ 3150 (Echelon) 32 KByte EPROM to download application firmware • LonWorks™(Echelon) connection to the TS_AC01 unit with a transfer rate of 78 kbps • Alphanumeric graphic liquid crystal display (LCD), back-lit, with two lines of 16 characters • Bi-directional reader with manual swiping for magnetic cards (track 2, ISO/ABA 7811 standard). • Numeric-function Keyboard with 16 keys • 1 double-colored LED signal: green LED for the correct reading and red/yellow for invalid • Variable Tones for valid/invalid transactions • Management of two dry contact digital inputs to control the door status • Management of two relay outputs (1A@30V) to command door unlock and signal external outputs • Tamper protection of the unit to prevent opening Photo ID Station Evolis Dualys Series Logitech QuickCam Pro 4000 Logitech P/N 961239-0403 Evolis Pebble Series • Up to 140 cards per hour 3Com® Watchport V USB Camera 3Com P/N 00371800 Parallel PhotoID MiniTower • Intel Pentium 4 processor, 1000BaseT • Integrated Ethernet adapter, online HD storage configurable to meet customer requirements Fargo DTC500 Series ® P/N TP_U01 (0.8A), TP_U03 (4.5A) • LonWorks™ (Echelon) connection to the TemaServer control units, with a communication speed of 78 kbps • Protection from power overloads • LED signal: green LED for “correct functioning,” flashing red for “errors in the communication signal,” red for “device out of order” and yellow for “Echelon connection is active” • Lead battery backup, with full functionality for 4 hours in case of network failure • Tamper protection of the unit to prevent opening m m m M m LON® 600 Rou e Coax Cable w w Phys ca Laye Repea e PLR P N ERS02001 m m w Excel Life Safety Sensors Model Type Features TC806 Photoelectric • Low-profile design, low current draw • Tamper-resistant wiring base • Integral insect resistant screen to reduce nuisance alarms • Dual LEDs provide 360-degree viewing • Optional remote LED annunciator • Built-in test mechanism TC807 TC808 TC840 Acclimate Ionization Thermal 135° ROR/FT 190° FT Multi-Criteria Photoelectric Thermal • • • • • • • • • TC844 Filtrex™ Harsh Environment Photoelectric • • • TC846 Pinnacle™ Ultra-High Sensitivity Laser Smoke Detector 0.02% - 2.00%/ft Obscuration TC809D1004 TC809A1059 TC810R1024 TC810N1013 TC811A1006 TC809B1008 TC841A1000 HAZM-8 HFAN-C • • • • • • • Provides additional fault tolerant (RAID-5) video storage. Scales from 10’s to 100’s of terabytes. DVM supports any Windows 2000-compatible off-the-shelf storage device including Direct or Network Attached Storage (DAS or NAS) or Storage Area Network (SAN) systems Network Switches DVM Communicates using TCP/IP network protocol using industry-standard Ethernet technologies. The network switch links the video streamers to the camera server(s) and camera servers to clients 16 push button inputs and 32 LEDs 32 LEDs 8 x 3 position switches and 8 x 3 LEDs 32 relays m LF Reade P N RLF00001 • • • • • • Simple Network Management Protocol (SNMP) IEEE 802.1D bridging capability and loop detection IEEE 802.1Q tagged VLANs IEEE 802.1 traffic prioritization for multiple QoS levels Support for multicast traffic Non-blocking, wire-speed access across all ports m Junc on Box P N FJB00001 & EJB00001 Pan/Tilt/Zoom PTZ Cameras Axis: ............................................... 2100 & 2110 Honeywell: ..................................... KD6i Digital Dome Video Encoding and Streaming Axis: ............................................... 2400+/2400 Blade, 2401+/2401+ Blade, 241S/241Q , MPEG, 241S/241Q, MPEG4 MegaChips: .................................... OpennetView, MD100, MJPEG encoding Sungjin:.......................................... CamStation CS100 m m w m w W W M W w W m m • Up to120 cards per hour m m m m m w Rugged, water-proof, chemical-resistant tags designed for harsh environments and for direct mounting to metal objects (metal cases, truck bumpers). Tags are 2.19 x 4.13 x 0.56 inches • Standard metal mount tag (AT-132-M) • Beacon metal mount tag (AT-132-M-B) • Beacon metal mount tag with temperature sensor (AT-132-M-BA) w W w M m m W Bene s o Ene gy Manage m m w m m m m m w m m Me e Managemen es Suppo ed U W M W m En e p se Demand Managemen m m w m m w m m Pe sonne Tag P N ERS01201 PBE00433 & ETB00433 2 Cargo Tag (P/N: AT-132-L) Rugged, water-proof, chemical-resistant tags designed for direct mounting to metal cargo containers. Tamper detect wire included which loops through cargo lock. Tags are 2.19 x 4.13 x 0.56 inches • Standard cargo tag (AT-132-L) m m Personnel Tags (P/N: AT-132-P, AT-132-P-B) A e Tag P N ALB00001 PLB00001 & ART00433 w w A ch ec u e Op ons M w M m m m LON® 600 Rou e w w Me e s m www www m m w M wm m W M m www W www m W M n e na ona za on Se ve Requ emen s M m M m m W M mm w C en Requ emen s m L cens ng m m m M m M m M M m m m m M w The water-proof personnel tags are standard ISO prox size and have a slot for clip or lanyard attachment. Tags are 2.19 x 3.44 x 0.25 inches • Standard personnel tag (AT-132-P) • Beacon personnel tag (AT-132-P-B) m m m m m M Vehicle Tags (P/N: AT-132-V, AT-132-V-D) Rec angu a Equ pmen Tag P N ETB00433 & ETF00433 m m m w m m w m Honeywell: ..................................... Honeywell Security Products, Ultrak UltraDome, The water-proof vehicle tags are standard ISO prox size and are made to mount on the inside windshield of cars and trucks. Tags are 2.19 x 3.44 x 0.25 inches • Standard vehicle tag (AT-132-V) • Standard vehicle tag with tamper disable (AT-132-V-D) m Ova Equ pmen Tag P N EQB00901 EQB00903 & WSE00433 w w w W w m m W m m m m M m m Desc p on Sys em m M M M M M Op ons W Asse Loca o m M m m m m W Wrist Strap/Prisoner Tag (P/N: AT-132-W) Rugged, water-proof tag designed to be attached to wrists or ankles of prisoners or patients for location tracking and perimeter alarming. Attachment of tag arms the conductive tamper strap, which then generates a tamper alarm if it is ever cut. The tamper strap is disposable • Standard wrist strap tag (AT-132-W) m m m m W Axcess FlashBus MV Lite Video Capture Card Parallel mM Metal Mount Tags (P/N: AT-132-M, AT-132- M-B, AT-132-M-BA) Ped a c A zhe me s Tag P N PTA00433 Pan/Tilt/Zoom (PTZ) Camera Support Integral Technologies® P/N 3280 • Allows use of any analog camera • Available in PCI or AGP Fargo® Pro-LX w m m mM m M w Fob style tags that are designed to be attached to key rings. Tags are 1.31 x 2.81 x 0.31 inches • Standard tag with replaceable battery – not water-proof (AT-132-PF-R) • Standard tag with replaceable battery and duress alarm – not water-proof (AT-132-PF-C) • Ruggedized standard tag “casino key tag”– water-proof (AT-132-RF) FlashPoint 3Dx Lite Video Capture Card • Up to133 cards per hour Ene gy Manage Founda on Key Fob Tags (P/N: AT-132-PF-R, AT-132- PF-C, AT-132-RF) m m w w mm m w Water-proof tags that attach directly to equipment (laptops, computers, etc.) to monitor location and generate perimeter alarms in conjunction with activators and RF receivers. Tags are 1.25 x 2.56 x 0.38 inches • Standard asset tag (AT-132-A) and with tamper (AT-132-A-T) • Beacon asset tag (AT-132-A-B) and with tamper (AT-132-A-BT) m m m W W s Mo he Pa en Tag P N PWB00901 & EWB00001 Fixed Camera Support Other: ............................................. American Dynamics Speed Dome, Bosch AutoDome G3A, Canon VC-C3/C4/C4R, Daiwa DMP 15, Ernitec Orion, Lilin FastDome, Molynx Surcha, Panasonic WVCS850/854, Pelco SpectraDome, Sony EVI-D30/D31/G20/G21 w w W w m w m m m Asset Tags (P/N: AT-132-A, AT-132-A-B, AT-132-A-T, AT-132-BT) w m Analog Cameras Analog camera signals are input into a video streamer and converted into a digital format and transmitted across a standard LAN/WAN. DVM supports industry-standard NTSC and PAL analog cameras m w m m Baby Tag P N BTB00433 Video Streamers convert analog NSTC or PAL camera images into highly compressed digital video streams that are transmitted across a standard LAN/WAN to DVM camera Servers for indexing and storage. Use Axis Communications, MegaChips or Sungjin w m w m • Standard tags provide location change events only when they enter activator fields • Beacon tags provide location change events when they enter Activator fields and when they move between areas covered by Receivers. The standard beacon rate is once per hour however, through special orders this can be set from once per minute to once every 18 hours m m m w w w W m m m m m Axcess Tag Styles w IP Network Cameras Fixed Cameras Axis: ............................................... 205, 206/206W/206M, 210, 211, 2100, 2110, 2120, 2420, 2420IR Activator antenna that is integrated into a picture frame to provide unobtrusive monitoring • Standard size is 16 x 20 inches (P/N: AT-132-A-F8) • Large size is 20 x 26 inches (P/N: AT-132-A-F10) w m IP Network cameras combine the video encoding and streaming functions of the video streamer with a security camera. Digital video streams that are transmitted across a standard LAN/WAN to DVM Camera Servers for indexing and storage. Use Axis Communications Picture Frame Activator Antenna (P/N: AT-132-A-F8 & AT-132-A-F10) m M w m Activator antenna constructed of plexiglas, which is made to be installed above or next to a door • Thin plex antenna is 4.5 x 37 inches in size (P/N: AT-132-A-PT) • Thick plex antenna is 9 x 52 inches in size (P/N: AT-132-A-PW) • Range up to 8 ft. for personnel tags and 3 ft. for asset tags w m m m Energy Management w m m w m w w Plex Activator Antenna (P/N: AT-132-A-PT & AT-132-A-PW) M m m m m w Activator antenna constructed of plexiglas, which is made to be installed in a ceiling (replaces one ceiling tile) • 21 x 21 inches in size • Range up to 8 ft. m m m Use off-the-shelf storage network switches with the following minimum specifications: Honeywell: ..................................... Honeywell Security Products, Ultrak KC Professional Series Other: ............................................. Any NTSC or PAL analog camera ACM-16AT ACM-32A SCS-8 LDM-R32 RF Reade P N RDF00001 E s Tag S y es m w m Overhead Activator Antenna (P/N: AT-132-A-PO) m Use Infotrend or other off-the-shelf storage subsystem with the following minimum specifications: RAID Levels: ................................... 0, 1, 3, 4, and 5 Redundancy: .................................. Hot-swappable drives, hot-sparing, redundant power supplies, redundant RAID controller Drives Supported: .......................... 4, 8, 14, or 42 Drive Types: ................................... Ultra ATA/133, Ultra ATA/100, or SATA Data Rebuild: ................................. 40GB storage RAID Controller: ............................. RAID-5 fault tolerant storage, capacity dependent on application SCSI Interface: ............................... SCSI Ultra160 O/S Supported: .............................. Windows 2000 m m m m m m Optional Video Storage Subsystem (Infotrend Technology) Thermistor sensing circuit for fast response Rate-of-rise detection model available Dual sensor LEDs provide 360-degree viewing Modern low-profile design Compatible with Honeywell CLIP and FlashScan loop transmission Automatically optimizes performance for each installed location Continuous monitoring of detector sensitivity Digital pulse-width encoded communication with noise immunity Compatible with Honeywell CLIP and FlashScan™ intelligent High-density Filtrex™ filter eliminates the need for sensor cleanings Filtrex™ filter self-monitors clogs and reports a trouble condition at the panel when replacement is needed Two sensor LEDs provide status indication at the control panel Provides rotary-decade switches to set sensor address Fast response to detect very early particles of combustion Ultra-high sensitivity capability On-board drift compensation Transient rejection algorithms Environmental tracking Wide sensitivity range Dual Input Monitor Module Intelligent Monitor Module Relay Module Control Module Intelligent Isolator Module Intelligent Mini-Monitor Module 2-Wire Interface Module 2-Wire Interface Module Fan Control Module Ex e na Re ay Box P N NXB00001 m m m m Very thin activator antenna encapsulated in a Kapton sheet. Designed to go under carpet, inside of non-metallic turnstiles or inside walls • 10.5 x 21 inches in size • Range up to 8 ft. for personnel tags and 6 ft. for asset tags m m PRODUCT FEATURES Flex Activator Antenna (P/N: AT-132-A-F) m m m LON Processor: ...................................... Intel Pentium IV 2.8GHz or greater (Dual processors recommended). System Memory:............................ 1GB RAM Floppy: ........................................... 3.5”, 1.44MB CD ROM:......................................... 24X or greater System Storage: ............................ 40GB storage Video Storage: ............................... RAID-5 fault tolerant storage, capacity dependent on application Input Devices: ................................ Standard Windows keyboard, mouse Monitor:.......................................... 15” SVGA color Operating System: ......................... Windows 2000 Server, Windows 2003 Server Road Loop Activator Antenna (P/N: AT-132-VL-S & AT-132-VL-D) Provides tag wake-up field for vehicles when connected to an activator and mounted in roads or non-metallic doorway floors • Single lane road loop version (P/N: AT-132-VL-S) • Dual lane road loop version (P/N: AT-132-VL-D) ® R Reade P N RDT00001 When used with an activator antenna, it generates a “wake-up” field for all Axcess tags and forces them to transmit • Operates at 126 KHz using 24 VDC power • Standard one antenna version (P/N: AT-132-AT) • Dual antenna version for in/out vehicle gates (P/N: AT-132-AT-D) • When used with an activator antenna it provides precise location to a small area (door, elevator cab, gate, muster zone) • Wake-up field can be adjusted using 20-turn adjustment screw • -40 to 85ºC operation Unde s and and Con o Ene gy Ene gy Manage Activator (P/N: AT-132-AT & AT-132-AT-D) m w Uses off-the-shelf PC with the following minimum specifications: P/N TK_C21 • NEURON CHIP™ 3120 (Echelon) • 4 balanced inputs with a range between 0 and 12 V • 4 open collector outputs with a range between 0 and 12 V up to 100mA • LonWorks™ (Echelon) connection with a transfer rate of 78 kbps • Tamper protection of the unit to prevent opening *Tema Power – Power Supply Unit m m DVM Camera Server ® • Up to 140 cards per hour w Processor: ...................................... Intel Pentium IV 2.8GHz or greater (Dual Xeon recommended). System Memory:............................ 1GB RAM Floppy: ........................................... 3.5”, 1.44MB CD ROM:......................................... 24X or greater System Storage: ............................ 40GB RAID-1 storage Input Devices: ................................ Standard Windows keyboard, mouse Monitor:.......................................... 15” SVGA color Operating System: ......................... Windows 2000 Server, Windows 2003 Server Supports communication on: • Twisted pair copper Ceiling mounted device that receives coded RF transmissions from Axcess tags • Read range of 35-40 ft. • 315 MHz and 433.92 MHz versions • Ethernet/Wiegand output version (P/N: AT-132-NR-IP) • RS232/Wiegand output version (P/N: AT-132-NR-S) • FCC Part 15 and EC compliance • General area location precision • -30 to 85ºC operation m m APPL CAT ONS Laptop and computer theft deterrence Staff safety (location tracking and duress alarming) Long-range, wireless vehicle gate access control Cargo location tracking and tamper monitoring Prisoner/patient location tracking and perimeter alarming Casino key and cash box location tracking and theft deterrence RF Receiver (P/N: AT-132-NR-IP & AT-132-NR-S) m m Stores video streams and transmits video to clients. Number of database servers required dependent on application, minimum of (1) per system *Tema Key – Digital I/O Module P/N TK_S014 • NEURON CHIP™ 3120 (Echelon) • LonWorks™ (Echelon) connection with a transfer rate of 78 kbps • 2 balanced inputs with a range between 0 and 12 V • 2 powered open collectors output, holding current 1.2A, peak max 5A inductive load • Tamper protection of the unit to prevent opening PRODUCT FEATURES Manages the DVM system. Contains recording index, audit log, and web server (1) database server per system (1) optional redundant database server per system Excel Life Safety System – Flexible Network Communications *Tema Key – Magnetic Reader *Tema Key – Dual Wiegand Interface D011 • • • • • • • • • • • • P/N TS_AC01 • CPU68EN302 bi-processor including a 68000 (32 bit architecture) and onboard Ethernet controller • Dialer support with LAN or as a backup to LAN • Industry standard LON architecture • Fault tolerant controllers and power supplies • Management of up to 8 doors with TemaKeys on both directions • Management of up to 64 I/O • 1 MB FLASH EPROM to download application firmware via FTP • Up to 60.000 cardholder capacity • Up to 40.000 transactions buffer • Peer-to-peer communication for fast front-end independent decision making • Onboard clock/calendar chip with automatic management of DST • Onboard battery backup, with full functionality for 4 hours • Full Time and Attendance functionality E s Asse Loca o DVM Database Server • High-contrast lines and text • LCD displays custom text messages in graphic annunciator enclosure - Surface or semi-flush mounting with optional trim - Field-installation option • • • • • • Asset Locator-Axcess – Cost-effective solution targeted at c mm m m Excel Life Safety System – LCD80 Annunciator *Tema Server – Control Unit 92995100063-B Specification Data P/N OP10HON • Lowest profile HID compatible card reader • Typical read range: 2 - 3" • Wiegand output • Genuine HID™ compatible OmniSmart OS30 HMI Keypad W7751B, D, F • 1 Expanded input/output capacity actuator not included Inputs • 1 T7770 wall module • 2 resistive inputs • 1 voltage input • 3 dry contact inputs • 1 bypass button input Outputs • 8 triac outputs • 1 LED output OmniProx™ OP10 92995100063-B Specification Data P/N OP30HON • Mullion size • Typical read range: 4" • Wiegand output • Genuine HID™ compatible D013 • IP65 rated enclosure with one piece facia. • Graphics capable, 40 character by 15 line backlit display. • Positive action, tactile keys. • Internal sounder for alarm annunciation. • 12 VDC operation. • Context based, soft menu user interface. • User selected Console status display, showing IntelliBus polling, IntelliBus status and Console system information. • LED indication built into selected keys for instant indication of critical system states, such as alarm, system mode and exit timer running. • Tamper protected enclosure. • Switch selectable biasing and termination resistors for RS485 connection. • Supervised IntelliBus interface with DES encryption. • Field upgradeable firmware. APPLICATIONS: Asset Locator-Eiris – High-performance solution targeted at healthcare and museum applications Uses off-the-shelf PC with the following minimum specifications: P/N TS_TA31 • CPU68EN302 bi-processor including a 68000 (32 bit architecture) and onboard Ethernet controller • Bi-directional reader with manual swiping for magnetic stripe cards • Multi-language management of the user interface • Up to 15.500 cardholder capacity with full time and attendance functionality • Up to 65.000 transactions stored on a removable cartridge with Flash EPROM • Lead battery backup, with full functionality for 4 hours in case of network failure • Tamper protection of the unit to prevent opening OmniProx™ OP30 HMI Console • Modular system designed for medium to large building and campus applications • Large quarter VGA LCD automatically displays system messages and alarms • 100 node, over 258,000 points with under 5-second alarm response over any size network • Total network wring over 100Km • 258 devices per loop, 2,580 devices per node • Every point can be viewed and controlled from any node • Local, proprietary and central station operations with integral alarm printer option • Modem communicator option • Graphic, text/LED, and keypad/display annunciator options SMOKE † Excel Life Safety System – XLS2000 *Tema Server – Magnetic Terminal Lon W7750B/C Constant Volume AHU Controller Inputs • 1 T7770 wall module • 4 resistive inputs • 2 voltage inputs • 4 dry contact digital inputs • 1 bypass button input Outputs • 8 triac outputs (W7750B) • 1 LED output • 5 triac and 3 analog outputs (W7750C) VAV Box Controller W7751 Ethernet Ethernet W7750A Constant Volume AHU Controller Inputs • 1 T7770 wall module • 1 resistive input • 2 dry contact digital inputs • 1 bypass button input Outputs • 6 relay outputs • 1 LED output P/N TS_TA32, TS_TA33 • CPU68EN302 bi-processor including a 68000 (32 bit architecture) and onboard Ethernet controller • Bi-directional reader with manual swiping for proximity cards • Multi-language management of the user interface • Up to 15.500 cardholder capacity with full time and Attendance functionality • Up to 65.000 transactions stored on a removable cartridge with Flash EPROM • Lead battery backup, with full functionality for 4 hours in case of network failure • Tamper protection of the unit to prevent opening Wiegand 74-2956 Specification Data • Proven PID space temperature control algorithm • Integral or packaged economizer control • Separate intelligent recovery rates for heating and cooling • Demand limit control temperature setpoint in energy saving direction • LonMark profile 8030 Software-based digital CCTV video management platform Uses off-the-shelf PC, storage, and networking hardware Live viewing and playback while recording Camera pan/tilt/zoom control from any client on the network Continuous, scheduled, alarm, pre-alarm motion, and user-activated recording modes Up to 30fps performance on all channels Communicates using TCP/IP network protocol using industry-standard Ethernet technologies • Full integration with EBI including direct access to alarm recordings from EBI alarm/event summary display • High-speed SQL-based search engine (date, time, camera, operator, point, alarm) • Digitally signed recordings and audit trail • Redundant server for complete fault tolerance (optional) • MJPEG and MPEG4 support • Video Analytics; object tracking, motion detection, object classification. Coax Cable 1 XFR522 Module Type: ..................................... Manual override for XFL522 Manual Override Switches:........................................... 8 2 XFR524 Module Type: ..................................... Manual override for XFL524 Manual Override Switches:........................................... 6 3 XSL511 Module Type: ..................................... Connector module for XFL521, XFL522, XFL523, XFL524 4 XSL512 Module Type: ..................................... Manual disconnect module between terminals and I/O modules 5 XSL513 Module Type: ..................................... Terminal block for XFL521/522/523 6 XSL513 Module Type: ..................................... Terminal block for XFL524 Constant Volume AHU Controller W7750 IQ200 Base 2-door Controller IQ400 4-door Controller IQ600 6-door Controller IQ800 8-door Controller IQ1000 10-door Controller IQ1200 12-door Controller Ultimate Controller IQELV Controller • Base 2-door & 4-door units can be upgraded to 6, 8, 10 & 12 door units • Base 2 door • 2 reader ports • 6 outputs (2 x relay, 4 x voltage) • 10 status inputs (5 configurable, 5 free) • Upgradable to (12-door controller) • 12 reader inputs • 26 outputs (12 x relay, 14 x voltage) • 30 status inputs (25 configurable, 5 free) • Add On modules available • Output Bd – 16 contact input + 16 relay output • SAM Bd – 8 or 16 supervised inputs • 12 VDC Power • Up to 24,000 card capacity • Ethernet, RS232, RS485 & Dial Up host communications Ultimate Series • On board Ethernet communications • LAN/WAN Connectivity • Up to 80,000 card capacity IQELV Series • Full Floor Selective Elevator Access Control • Destination Reporting • 2 & 4 Elevator readers • 16 – 64 Floor Control SIM32 • 32 Supervised 5 state alarm inputs • 4 relay outputs • Ethernet, RS485 & Dial Up host communications • Can be integrated with IQ series door controllers Wiegand 74-2145 Specification Data Analog Input XFL521B Module Distributed Module Type:................... Analog input No. of Inputs: .................................... 8 Type of Inputs .................................... 0 to 10 volts .......................................................... 0 to 20 mA or 4 to 20 mA .......................................................... 20k NTC .......................................................... PT1000 Accessories: ...................................... 3 4 5 Analog Output XFL522B Module Distributed Module Type:................... Analog output No. of Outputs: .................................. 8 Type of Outputs: ................................ 0 to 10 volts No. of LEDs: ....................................... 8 Accessories: ...................................... 1 3 4 5 Digital Input XFL523B Module Distributed Module Type:................... Digital input No. of Inputs: ..................................... 12 No. of LEDs: ....................................... 12 Accessories: ...................................... 3 4 5 Digital Output XFL524B Module Distributed Module Type:................... Digital output No. of Outputs: .................................. 6 No. of LEDs: ....................................... 6 Type of Outputs: ................................ 6 Isolated changeover contacts Accessories: ...................................... 2 3 4 6 I/O Point Capacity • 22 physical points • Up to 256 pseudo points • 46 network variables supported on the LonWorks® Network Application module:........................... Flash–EPROM Engineering tool: ............................... Excel CARE PCSC Controller Honeywell Asset Locator supports two hardware solutions, which enable it to be customized for most markets and applications • • • • • • • *Tema Server – Proximity Terminal P/N HK-2 • Hand geometry reader • Up to 32512 users with memory upgrade • Direct enrollment integration to EBI • Outdoor version available USB LON Distributed Input/Output Modules D001 PRODUCT FEATURES: • Real-time location tracking and status monitoring solution • Radio-frequency (RF) based tracking for area location • Low-frequency RF (Activator) based tracking for precise door/ elevator location • Tag models include: asset, personnel, cargo, vehicle, and prisoner/wrist tags Building Building Asset Location Asset Location Asset Location Asset Location Security Security Security Life Safety Building Life Safety LifeDigital Safety Life Safety Energy Digital Video Security Energy VideoDigital Video Energy Digital VideoEnergy Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management Management HandKey II PCSC Access & Security Controller Ethernet 74-3666 Specification Data Model Type • Excel 50 UPC – without operator interface; Excel 50 UMMIPC-with operator interface The XLS2000 FS90 Fire and Security (F&S) family of real-time, microprocessor-based Honeywell LifeSafety ManagerTM provides unprecedented protection of your building’s assets and occupants. This life-safety application incorporates: • Intelligent, microprocessor-based devices, including multi-sensor detectors that provide early warning of smoke and fire conditions, and virtual elimination of nuisance alarms • Rapid and reliable fire alarm controller peer-to-peer communications network • Control of the facilities’ HVAC equipment, such as fans and dampers, to contain smoke and create safe havens • Releasing of fire doors to permit safe exit • Sprinkler supervisory status of suppression systems, sprinkler valves, and fire pumps TemaLine is redefining the concept of integrated security solution subsystems for today and tomorrow. • Designed for unparalleled system reliability and availability using the “Shared Load” concept • New distributed architecture and modularity reducing the management load on the supervisory system • Multi-application/multi-functional controller provides access control, time and attendance and intruder protection • Optional redundant TemaServer and “Shared Load TemaPower” • Single standalone application to a fully integrated EBI solution High Security Manager D001 • Scalable and flexible architecture. The design of the High Security Manager (HSM) allows the field interface devices to be mounted within the controller enclosure or remotely in separate enclosures. The standard RS485 communications hardware allows connection of the interface devices via copper cable or optical fibre (when used with a suitable converter). • Small form factor; may be installed in a variety of enclosures. • High security locking and tamper detection kits are available for high security installations. • 12 VDC operation. • Control and monitoring of a total of 1024 supervised sectors, which may be any combination of the following end of line module types: • Up to 256 Type 1 high security end of line modules (D006). • Up to 1024 Type 2 high commercial grade addressable end of line modules (EL135/EL138). • Up to 88 commercial grade resistor end of line modules. • Up to 128 XSMP legacy Type 1 DTMF end of line modules (EL131). • Supports up to 16 human machine interfaces (HMI). This may be any combination of HMI Consoles (D013) or HMI Keypads (D014). • Supports up to 128 relay outputs. • Solid state event logging using a USB Flash Drive (UFD). • Parallel port supports a supervised, XSMP event logging printer if hard copy output is required. This may be used in conjunction with the UFD event log. • 4 RS485/RS422 serial communication ports. • 1 RS232 serial communication port. • 1 RS232/RS485/RS422 serial communication port. • 2 USB 1.1 ports. • 1 10Mb Ethernet port. • 8 onboard normally open or normally closed contact relay outputs with 30 VDC, 1.5 A contact rating. • 8 onboard digital inputs for system monitoring. • Onboard vibration detector. • LED indication of system running, or “heartbeat” indicator. • Compact Flash (CF) card based solid state hard drive. • Industry standard components including PC/104 compatible CPU module allowing easy expansion of the CPU module. • 300MHz x86 compatible CPU with 128MB RAM. • Linux operating system. • Standard Error type diagnostic output and user command interface to monitor and troubleshoot system operation. • Honeywell IntelliBus protocol used for interface device and HMI communications. • The IntelliBus protocol supports DES data encryption to individual interface devices when the system is to be used in high security installations. Both encrypted and non-encrypted devices may be connected to the same channel. • MS Windows based configuration tools. System configuration may also be performed via the HMI Console. • Support for multiple user privilege levels. • Customisable logic equation operation and programmable key stroke macros. • Field upgradeable firmware. • Communications to CSS, such as EBI, via 3-DES encrypted terminal server. • C-Tick compliant and SCEC endorsed. PRODUCT FEATURES: PRODUCT FEATURES: PRODUCT FEATURES: Asset Locator - A real-time location tracking and monitoring solution for people and equipment Digital Video Manager (DVM) - A Flexible, Highly Integrated CCTV Solution with Advanced Capabilities. TemaLine A Comprehensive Solution for Security USB LON Smart Excel 500 Controller XCL5010 Same Power of the Excel 500 • Similar operator interface • Same software • Same bus configuration • Fully programmable using Excel CARE RS-485 C-Bus or LON 74-2036 Specification Data I/O Point Modules Analog Input XF521A Insert Card Module Type: ..................................... Analog input No. of Inputs: ..................................... 8 Type of Inputs: ................................... 0 to 10 volts .......................................................... 0 to 20 mA or 4 to 20 mA .......................................................... NTC XF526 Insert Card Module Type: ..................................... Analog input No. of Inputs: ..................................... 8 Type of Inputs: ................................... 0 to 10 volts .......................................................... 0 to 20 mA or 4 to 20 mA .......................................................... NTC .......................................................... PT100, 1000, 3000, Balco Analog Output XF522 Insert Card Module Type: ..................................... Analog output No. of Outputs: .................................. 8 Type of Outputs: ................................ 0 to 10 volts +/- mA each Manual Override Switches:........................................... 5 No. of LEDs: ....................................... 8 XF527 Insert Card Module Type: ..................................... Analog output No. of Outputs: .................................. 8 Type of Outputs ................................. 0 to 10 volts +/- mA each Manual Override Switches:........................................... 0 No. of LEDs: ....................................... 8 Digital Input XF523 Insert Card Module Type: ..................................... Digital input No. of Inputs: ..................................... 12 No. of LEDs: ....................................... 12 Inputs 1 and 2: .................................. Digital input or fast totalizer Inputs 3-12: ....................................... Digital input or slow totalizer Digital Output XF524 Insert Card Module Type: ..................................... Digital output No. of Outputs: .................................. 6 Type of Outputs: ................................ 5 change over contacts .......................................................... 1normally open contact Manual Override Switches:........................................... 5 No. of LEDs: ....................................... 6 XF529 Insert Card Module Type: ..................................... Digital output No. of Outputs: .................................. 6 Type of Outputs: ................................ 5 change over contacts .......................................................... 1 normally open contact Manual Override Switches:........................................... 0 No. of LEDs: ....................................... 6 Three Position Output XF525 Insert Card Module Type: ..................................... Three position output No. of Outputs: .................................. 3 Type of Outputs: ................................ Floating control Manual Override Switches:........................................... 3 No. of LEDs: ....................................... 3 pairs of 2 Power Module XP502 Power Module Module Type: ..................................... Power supply Input: ................................................. 24Vac + 10%/-15% Output:............................................... Class 2, 24Vac Switches:........................................... 1 No. of LEDs: ....................................... 3 74-3671 Specification Data XFC3A06001 Terminals:.......................................... Fixed permanent Digital Inputs: .................................... 4 Digital Outputs:.................................. 4 Analog Inputs: ................................... 4 (20K NTC) Analog Outputs: ................................. 2 (VDC) XFC3D06001 Terminals:.......................................... Removable Manual Override: ............................... 6 No. of LEDs: ....................................... 10 Digital Inputs: .................................... 4 Digital Outputs:.................................. 4 Analog Inputs: ................................... 4 (20K NTC) Analog Outputs: ................................. 2 (VDC) PRODUCT FEATURES: IQ Series, a 100% distributed intelligent access control system, incorporated with an inherent “Upgrade Bus”. 100% Distributed Intelligence means that there is no degradation in security level, even when the host is “offline”. UltimateTM Series, a 100% distributed architecture with open architecture to support TCP/IP protocols and direct connections to LAN/WAN networks. It offers superb management of access control, alarm monitoring and output control subsystems. Building Asset Location Asset Location Security Building Life SafetySecurity Life Safety Digital Video Digital Video Energy Management Management Management Management Management Management Management Management Management Management Management Excel 500 Controller XC5010C † Smart I/O Module 74-3029 Specification Data I/O Point Capacity Analog Inputs: 8 ................................ 0 to 10 Vdc .......................................................... 0 to 20 mA .......................................................... (w 499 Ω resistor) .......................................................... NTC 20k ohm Analog Outputs: 4 .............................. 0 to 10 Vdc Digital Inputs: 4 ................................. 3 of 4 fast totalizer Digital Outputs: 6............................... Triac 800 mA (all 6 Triacs max 2.4A) *Please contact your Honeywell sales representative for information on the Tema product line. HEAT • A family of distributed control products that are open and easy to use, the EXCEL 5000 OPEN System is a proven performer that defines versatility • Every control device in the EXCEL 5000 OPEN System family uses LonWorks®-based open communications protocol – the worldwide standard in building control – so you can expect smooth, efficient interoperability between devices • Third-party LonMark device support allows additional devices from multiple manufacturers to be added to the existing LON bus • Stand-alone operation at the field control bus level for maximum performance and reliability • Free topology transceiver technology simplifies wiring, uses standard network tools • True Integration with fire, security, and digital video systems creates application opportunities never before available Distributed Input/Output Accessories PRODUCT FEATURES: The High Security Manager (HSM) is a protection system designed to detect intrusions and other critical conditions when used with the Enterprise Building Integrator (EBI). The HSM monitors multiple areas, receiving input and providing localized reporting and control. • A single I9000 Control Unit can simultaneously monitor many different buildings, areas with high security door sensors. Other compatible detectors and output devices can be added to the system such as • motion sensors, sound detectors, lights, sirens and buzzers. Excel 50 Controller XL50UMMIPC-LON PRODUCT FEATURES Building Management PCSC Controllers Access Control and Security System 74-3487 Specification Data • Ethernet to RS232 or RS485 Converter, DB25 connecting via DB25 serial • 128 – 256 bit AES NIST certified encryption SPECIAL APPLICATIONS Network Device Server – 14006700 Series If LON: † UUKL Listed in UL conforming configuration. EXCEL 5000® OPEN™ System Architecture: Designed for unmatched DDC control versatility and true open system flexibility. Ethernet Redundant Ethernet Network (optional) 51-52-03-31 Specification Data • Ethernet (Modbus TCP) connectivity to EBI • Industrially hardened, hot swap I/O cards • Fast updates-27 msec logic, 0.5 sec analog • High resolution 15 bit universal analog inputs • Embedded loop auto tuning MODULES 74-3445 Specification Data • TCP/IP capable, offers a wide range of network connectivity options and online system diagnostic support Ethernet HC900 • Provides network connectivity between Ethernet LAN and LONTalk (FTT-10A) bus NOTE: i.LON® 600 currently scheduled with Underwriters Laboratories for UUKL testing and listing. Contact your Honeywell Sales representative for current standing. ANNUNCIATORS Building Network Adapter (BNA) Q7055A Lantronics UDS-10 Terminal Ser ver i.LON® 600 Router If C-Bus: Ethernet Redundant LAN (optional) Integral Technologies® P/N 3047 • Allows use of any analog camera • Only available in PCI M M m Energy Applications Honeywell, Enterprise Buildings Integrator (EBI), EXCEL 5000 OPEN, Excel Building Supervisor (XBS), Excel Building Supervisor Integrated (XBSi), Excel Plus, Excel Classic, Excel 500, Smart Excel 500, Excel 50, Excel Security Manager (XLS/XLS1000), Excel Life Safety, Delta 1000, Delta 2000, Intelliguard 9000 (i9000) and DeltaNet FS90 are trademarks of Honeywell International, Inc. All other brands are trademarks of their respective companies. Modbus is a registered trademark of the Modbus Organization, Inc. HVAC Controls LONMARK is a trademark of Echelon Corporation Security and Access Control Fire and Life Safety Systems CCTV & Digital Video Asset Tracking Above information subject to change without notice. Not all products available in all regions. P n ed n Aus a a Re evan o he Pac c Reg on