Download Amana SS 4 Product specifications

Transcript
AMH95 G as F urnace
up to 96% AFUE
Standard Features
• Heavy-duty MillionAir® stainless-steel, dual-diameter tubular heat exchanger
• Stainless-steel secondary heat exchanger
• Durable SureStart® Silicon Nitride igniter
• Two-stage gas valve with technology that allows installer to activate the two-stage
valve with the flip of a dipswitch
• Self-adjusting feature automatically
adjusts to high- or low-stage operation
based on outside temperature without an outdoor temperature sensor
• Color-coded low-voltage terminals
with provisions for electronic air
cleaner and 24-volt humidifiers
• Control board stores last diagnostic codes in memory and outputs the
fault history to a flashing red LED
• Low continuous fan speed options offer quiet air circulation
• All models comply with California NOx emissions standards
Cabinet Features
• Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
• Designed for upflow or horizontal installation
• Airtight solid bottom for side return applications and easy-cut tabs for effortless removal in bottom air inlet applications
• Convenient left/right connection for gas/electric service
• Coil and furnace fit flush for most installation
Contents
Nomenclature ....................................... 2
Product Specifications .......................... 3
Dimensions ........................................... 4
Airflow Data .......................................... 5
Wiring Diagrams ................................... 6
Accessories ............................................ 8
* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty (good for
as long as you own your home) and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is
not required in California or Québec.
SS-AMH95
www.amana-hac.com
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
11/12
Supersedes 4/12
Product Specifications
Nomenclature
A
M
H
95
70
3
B
X
AA
1
2
3
4,5
6,7,8
9
10
11
12,13
Brand
A Amana® Brand
Revisions
Major and
Minor
Revisions
Airflow Direction
C Downflow/Horizontal
D Dedicated Downflow
H High Airflow
K Dedicated Upflow
M Upflow/Horizontal
N Natural Gas
X Low NOx
Description
V Two-Stage/Variable-speed
H Two-Stage/Multi-speed
S Single-Stage/Multi-speed
A
B
C
D
AFUE
95 95%
9 90%+
8 80%
045: 45,000
070: 70,000
090: 90,000
2
MBTU/h
115: 115,000
140: 140,000
www.amana-hac.com
Maximum
3
4
5
NOx
Cabinet Width
14”
17½”
21”
24½”
CFM @ 0.5” ESP
1,200
1,600
2,000
SS-AMH95
Product Specifications
Specifications
AMH95
0453BXA
AMH95
0703BXA
AMH95
0704CXA
AMH95
0904CXA
AMH95
0905CXA
AMH95
1155DXA
Input ¹
46,000
69,000
69,000
92,000
92,000
115,000
Natural Gas Output ¹
44,200
66,300
66,300
88,400
88,400
110,500
LP Gas Output¹
39,800
59,700
59,700
79,600
79,600
99,500
96.1
96.1
96.1
96.1
96.1
96.1
3
3
4
4
5
5
35 - 65
30 - 60
35 - 65
30 - 60
30 - 60
35 - 65
10” X 8”
10” X 8”
10” X 10”
10” X 10”
11” X 10”
11” X 10”
Horsepower @ 1750 RPM
⅓
⅓
½
½
¾
¾
Speed
4
4
4
4
4
4
Vent Diameter ³
2”
2”
2”
2”
3”
3”
Heating Capacity
AFUE ²
Available AC @ 0.5” ESP
Temperature Rise Range (°F)
Circulator Blower
Size (D x W)
No. of Burners
Disposable Filter Size (in2)
2
3
3
4
4
5
580
580
770
770
960
960
9.4
9.4
13.8
13.8
13.2
13.2
15
15
15
15
15
15
120
123
125
144
146
163
Electrical Data
Min. Circuit Ampacity 4
Max. Overcurrent Device (amps)
Ship Weight (lbs)
5
Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level. Low-fire rate is 75% of high-fire rate
DOE AFUE based upon Isolated Combustion System (ICS)
3
Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code
NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).
4
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with
National Electrical Codes. Extensive wire runs will require larger wire sizes.
5
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type
circuit breakers of the same size as noted.
1
2
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½” FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code
and/or all existing local codes.
SS-AMH95
www.amana-hac.com
3
Product Specifications
COMPONENT IDENTIFICATION
Dimensions
GMH95*****XA*
AIR
DISCHARGE
AIR
DISCHARGE
19 7/8”
AIR
INTAKE
PIPE
2" PVC
RIGHT SIDE
DRAIN LINE
HOLES
1 1/2
2
1 5/8
1
UNFOLDED FLANGES
UNFOLDED FLANGES
FOLDED FLANGES
FOLDED FLANGES
RIGHT SIDE VIEW
Model
AMH950453BXA
A
B
C
D
E
17½”
16”
13⅛”
12⅛”
13⅝”
AMH950703BXA
17½”
Cabinet Size
E12⅛”
13⅝”
16”
17½”
16”
17½”
16”
17½”
19⅜”
20⅞”
AMH950704CXA
A 16”
21”
AMH950904CXA
GMH950453BXA*
21”
GMH950703BXA*
AMH950905CXA
21”
AMH951155DXA
B
C13⅛”
19½”
24½”
GMH950704CXA*
19½”
17-1/2
19½”
23”
21
D
16⅛”
16⅛”
16
12-15/16
19-1/2
15-15/16
16⅛”
12-1/8
13-5/8
16
17-1/2
20⅝”
GMH950904CXA*
Notes:
• Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe
must be either 2” or 3” in diameter,GMH950905DXA*
depending upon furnace
input, number
of elbows,
length of run,
and installation
(1 or 2 pipes).
24-1/2
20-7/8
19-3/8
23
20-7/16
The optional combustion air pipe is GMH951155DXA*
dependent on installation/code requirements and must be 2” or 3” diameter PVC.
• Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace.
All dimensions
are in inches.
• Conversion kits for high-altitude natural
gas operation
are available. Contact your Amana distributor or dealer for details.
• Installer must supply the following gas line fittings, according to which entrance is used:
Left: One 90º street elbow; one 2½” pipe nipple; one 90º elbow; straight pipe; one ground joint union
Right: Straight pipe to reach gas valve
• Installations using a bottom return: Failure to unfold flanges will reduce airflow area by approximately 18%. This could result
in performance
andAirflow
noise issues.
NOTE:
area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and
noise issues.
Minimum Clearances to Combustible Materials
Position
Sides
Rear
Front
Bottom
Flue
Top
Upflow
0”
0”
1”
C
0”
1”
Horizontal
6”
0”
1”
C
0”
4”
6
C = If placed on combustible floor, the floor MUST be wood ONLY.
Notes
• For servicing or cleaning, a 24” front clearance is recommended.
• Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above.
• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility
clearances are greater.
• Approved for line contact in the horizontal position.
4
www.amana-hac.com
SS-AMH95
Product Specifications
Airflow Data
(CFM & Temperature Rise vs. External Static Pressure)
Model
Motor
Speed
Tons
AC¹
External Static Pressure, (Inches Water Column)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
CFM
CFM
High
Med
AMH95
0453BXA Med-Lo
Low
3
2.5
2
1.5
1,352
1,214
997
757
29
32
40
52
1,318
1,172
994
753
30
34
40
52
1,260
1,123
960
734
31
35
41
54
1,202
1,064
923
704
33
37
43
56
1,128
1,012
884
674
35
39
45
59
1,044
938
817
620
955
859
741
524
853
741
611
438
High
Med
AMH95
0703BXA Med-Lo
Low
3
2.5
2
1.5
1,449
1,192
981
750
41
50
61
79
1,409
1,172
962
730
42
51
62
81
1,326
1,141
943
714
45
52
63
83
1,273
1,094
917
692
47
54
65
86
1,201
1,046
888
657
49
57
67
90
1,194
973
830
620
1,136
904
764
570
1,018
793
665
502
High
4
2,069
29
1,965
30
1,871
32
1,756
34
1,661
36
1,549
1,415
1,275
3.5
1,752
34
1,724
34
1,667
36
1,603
37
1,488
40
1,402
1,290
1,082
3
1,437
41
1,437
41
1,417
42
1,369
43
1,320
45
1,256
1,140
984
2.5
1,184
50
1,177
50
1,161
51
1,132
52
1,095
54
1,047
928
837
High
Med
AMH95
0904CXA Med-Lo
Low
4
3.5
3
2.5
1,970
1,713
1,439
1,183
40
46
55
67
1,874
1,650
1,412
1,155
42
48
56
69
1,757
1,572
1,370
1,122
45
50
58
71
1,667
1,510
1,327
1,108
48
52
60
72
1,566
1,418
1,260
1,062
51
56
63
75
1,431
1,313
1,166
1,011
1,334
1,211
1,078
931
1,182
1,079
956
816
High
Med
AMH95
0905CXA Med-Lo
Low
5
4
3.5
3
2058
1718
1502
1305
39
47
54
62
1997
1685
1464
1277
40
48
55
63
1928
1632
1429
1253
42
49
56
64
1852
1586
1380
1212
43
51
58
66
1777
1520
1319
1175
45
53
61
69
1682
1458
1272
1127
1600
1369
1200
1081
1487
1281
1137
1010
High
Med
AMH95
1155DXA Med-Lo
Low
5
4
3.5
3
2,134
1,678
1,453
1,259
46
58
68
78
2,103
1,643
1,440
1,239
47
60
68
79
2,029
1,643
1,426
1,220
48
60
69
80
1,941
1,577
1,363
1,181
51
62
72
83
1,906
1,527
1,349
1,159
51
64
73
85
1,818
1,489
1,314
1,118
1,733
1,423
1,253
1,082
1,625
1,339
1,205
1,015
Med
AMH95
0704CXA Med-Lo
Low
¹
at 0.5” ESP
Notes
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating.
• The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower.
SS-AMH95
www.amana-hac.com
5
4
9
8
7
BL
2ND
STAGE
DELAY
HEAT
OFF
DELAY
12
11
10
YL
GY
FS
2
HEAT-H
JUNCTION BOX
.100
DOOR
SWITCH
WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
WH
AUTO RESET
PRIMARY LIMIT
CONTROL
PU
BL
C
2 CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER
PK
0
GND
C
3
2
JUNCTION
BOX
BR
OR
GAS VALVE (HONEY WELL)
GND
FLAME
SENSOR
DISCONNECT
2
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
HI VOLTAGE (115V)
HI VOLTAGE FIELD
3
3 FLASHES = PRESSURE SWITCH STUCK OPEN
4 FLASHES = OPEN HIGH LIMIT
5
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
6
6 FLASHES = OPEN ROLLOUT OR OPEN FUSE
7
7 FLASHES = LOW FLAME SIGNAL
8
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
LOW VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
4
LOW VOLTAGE (24V)
= CONTROL FAILURE
= SYSTEM LOCKOUT (RETRIES EXCEEDED)
4
L
BK
1 FLASH
EQUIPMENT GND
FIELD GND
FIELD SPLICE
SWITCH (TEMP.)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
A
REV ZONE
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN
STANDBY (NO THERMOSTAT INPUTS)
ECN
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED
BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
3
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY.
0904251
0140F00663 REV. A
N
WH
1
PK PINK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
GR
STEADY ON = NORMAL OPERATION
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
6
BL
OFF
C
N
RD
MANUAL RESET ROLLOUT LIMIT CONTROL(S)
( SINGLE CONTROL ON 45K BTU )
24 VAC
HUMIDIFIER
FRONT COVER
PRESSURE SWITCH
N
C
O
PM 1
GY
GY
HI
GND
TO 115 VAC / 1Ø / 60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
ID BLOWER
PRESSURE
SWITCH
L
TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
OR
WH
DISCONNECT
5
YL
OR
ELECTRONIC
AIR CLEANER
LINE-H
WH
WH
INDUCED DRAFT
BLOWER
6
10.500
BK
LINE NEUTRALS
BR
EAC-H
GND
CIRCULATOR
BLWR
HI -H
AT
HE
MANUAL RESET
AUXILIARY LIMITS
(1) IN UPFLOW
BLOWER DECK
(2) IN C'FLOW
BLOWER HOUSING
BURNER COMPARTMENT
N
O
COOL-H
PU
BLOWER COMPARTMENT
RD
HE LO
AT
-H
INTEGRATED CONTROL MODULE
INTEGRATED CONTROL MODULE
OR
CAPACITOR
ID
BLWR
IND
OR
WH
YL
GY
OR
BL
BR
HOT SURFACE
IGNITER
IGN
BK
CIRCULATOR
BLOWER
115 VAC
FS
PK
RD
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON 45K BTU)
24 VAC
FLAME SENSOR
WH
WH
BR
RO1 (5)
XFMR-H
YL
BK (HI)
BL (MED)
OR (MED LOW)
RD (LOW)
MANUAL RESET AUXILIARY AUTO RESET
LIMIT CONTROLS
PRIMARY
LIMIT
CONTROL
RO2 (11)
40 VA
TRANSFORMER
WH
GR
RD
WH
R
BK
LINE-H
SEE
NOTE 4
GND
HLO (1)
7
COOL-H
HLI (7)
W
TH (3)
1
115 VAC HOT AND PARK TERMINALS
NO
C
PSO (4)
PK
XFMR-H
SEE
NOTE 6
DIAGNOSTIC
LED
PS (10)
TO
MICRO
Y
BR
RD
GY
OR
*
FACTORY SETTINGS
SHOWN
GR
OR
OR
115 VAC NEUTRAL
TERMINALS
*
*
*
OR
G
⚡
1
5
ID BLOWER
PRESSURE
SWITCH
8
2
C
NO
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
BK
OFF
GY
PK
3
6
INTEGRATED
CONTROL
MODULE
24V THERMOSTAT CONNECTIONS
OR
FUSE
PM
FRONT COVER
PRESSURE SWITCH
BK
WH
BK
MODE
GAS
HI VALVE
MVL(2)
C
W Y
ON
C
MVH (12)
⚠
R
GND
GND (8)
MVC (9)
Warning
40 VA
TRANSFORMER
INTEGRATED
CONTROL MODULE
HUMIDIFIER
TR (6)
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
G
9
24 VAC
C
( 6.190 )
GY
115 VAC
24V THERMOSTAT
CONNECTIONS
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
OR
24 VAC
HUMIDIFIER
(.125)
(SEE NOTE 4)
NOTES:
1. MATERIAL: FLEXMARK PM 200 WHITE TC-245 L-23 SPEC 50K-8
Wiring Diagrams with Honeywell Valve
F
E
D
C
B
Product Specifications
www.amana-hac.com
SS-AMH95
2
I
Product Specifications
Wiring Diagrams with White-Rodgers Valve
INTEGRATED
CONTROL MODULE
HUMIDIFIER
C
GND
GAS
HI VALVE
R
G
W Y
BK
WH
BK
BK
OR
FUSE
INTEGRATED
CONTROL
MODULE
ON
OFF
2ND
STAGE
DELAY
MODE
*
*
2
1
6
5
4
8
7
BL
11
10
YL
HOT SURFACE
IGNITER
COOL-H
CIRCULATOR
BLWR
OR
HI -H
AT
HE
BR
EAC-H
PU
BLOWER COMPARTMENT
ELECTRONIC
AIR CLEANER
LINE-H
JUNCTION BOX
DOOR
SWITCH
GY
BURNER COMPARTMENT
WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
GND
BK
WH
WH
INDUCED DRAFT
BLOWER
WH
AUTO RESET
PRIMARY LIMIT
CONTROL
INTEGRATED CONTROL MODULE
L
HE O
AT
-H
OR
CAPACITOR
LINE NEUTRALS
INTEGRATED CONTROL MODULE
GR
WH
YL
ID
BLWR
IND
OR
BL
BK
RD
YL
CIRCULATOR
BLOWER
BR
WH
WH
BR
115 VAC
IGN
WH
PK
RD
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON 45K BTU)
24 VAC
FLAME SENSOR
GY
BK (HI)
BL (MED)
OR (MED LOW)
RD (LOW)
RO1 (5)
XFMR-H
GY
WH
ID BLOWER
PRESSURE
SWITCH
40 VA
TRANSFORMER
BK
LINE-H
SEE
NOTE 4
GND
NO
C
AUTO RESET PRIMARY
LIMIT CONTROL
RO2 (11)
FS
1
HEAT-H
HLO (1)
R
GR
PU
2
DISCONNECT
L
GND
N
TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
PU
BL
RD
YL
OR
N
O
OR
C
PK
WH
HUMIDIFIER
2 CIRCUIT
CONNECTOR
PM
HOT
SURFACE
IGNITER
HI
2
C
3
GY
1
N
O
C
FRONT COVER
PRESSURE SWITCH
GY
GND
BR
(HONEYWELL)
STEADY ON = NORMAL OPERATION
JUNCTION
BOX
1 FLASH
= SYSTEM LOCKOUT (RETRIES EXCEEDED)
2
N
WH
GND
FLAME
SENSOR
L
BK
DISCONNECT
LOW VOLTAGE (24V)
= CONTROL FAILURE
1
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
GR
OR
GAS VALVE
OFF
EQUIPMENT GND
LOW VOLTAGE FIELD
FIELD GND
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
HI VOLTAGE (115V)
FIELD SPLICE
HI VOLTAGE FIELD
SWITCH (TEMP.)
3
3 FLASHES = PRESSURE SWITCH STUCK OPEN
4
4 FLASHES = OPEN HIGH LIMIT
5
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
6
6 FLASHES = OPEN ROLLOUT OR OPEN FUSE
7
7 FLASHES = LOW FLAME SIGNAL
8
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
C
BL
TO 115 VAC / 1Ø / 60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
0
RD
MANUAL RESET ROLLOUT LIMIT CONTROL(S)
(
24 VAC SINGLE CONTROL ON 45K BTU )
ID BLOWER
PRESSURE
SWITCH
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
PK PINK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
0140F01027-B
SS-AMH95
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
⚡
PSO (4)
HLI (7)
W
BR
115 VAC NEUTRAL
TERMINALS
XFMR-H
SEE
NOTE 6
115 VAC HOT AND PARK TERMINALS
COOL-H
OR
C
NO
FRONT COVER
PRESSURE SWITCH
PS (10)
TO
MICRO
Y
TH (3)
OR
RD
GY
FS
G
OR
9
OR
*
FACTORY SETTINGS
* SHOWN
GY
PU
12
GY
HEAT
OFF
DELAY
DIAGNOSTIC
LED
3
MVL(2)
24V THERMOSTAT CONNECTIONS
115 VAC
24V THERMOSTAT
CONNECTIONS
C
40 V A
TRANSFORMER
C
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
24 VAC
MVH (12) AUXILIARY LIMIT CONTROLS
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
GY
Warning
OR
24 VAC
HUMIDIFIER
PM
⚠
GND (8)
MVC (9)
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
TR (6)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE
PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)
www.amana-hac.com
7
Product Specifications
Accessories
Model
Description
AMH95
0453B**
AMH95
0703B**
AMH95
0704C**
AMH95
0904C**
AMH95
0905C**
AMH95
1155D**
LPM-06
LP Conversion Kit (Springs & Orifice)
√
√
√
√
√
√
LPLP03
LP Gas Low Pressure Kit
√
√
√
√
√
√
FTK04
Twinning Kit
√
√
√
√
√
√
ASAS
Electronic Air Cleaners
√
√
√
√
√
√
AMU
Media Air Cleaners
√
√
√
√
√
√
HANG11
High Altitude Natural Gas Kit
1
1
1
1
---
1
HANG12
High Altitude Natural Gas Kit
2
2
2
2
---
2
HALP10
High Altitude LP Gas Kit
3
3
3
3
---
3
HAPS27
High Altitude Pressure Switch Kit
3
3
3
3
---
3
EFR01
External Filter Rack
√
√
√
√
√
√
DCVK-20
Horizontal/Vertical Concentric Vent Kit (2”)
√
√
---
---
---
---
DCVK-30
Horizontal/Vertical Concentric Vent Kit (3”)
√
√
√
√
√
√
017K00000S
Flush-mount Vent Kit
√
√
√
√
√
√
Notes
√
Indicates available for this model
2 Indicates 9,001’ to 11,000’ altitude
1 Indicates 7,001’ to 9,000’ altitude
3 Indicates 7,001’ to 11,000’ altitude
• All installations above 7,000’ require a pressure switch change.
• For installation in Canada, gas furnaces are certified only to 4,500’.
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing
commitment to quality products may mean a change in specifications without notice. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
8
www.amana-hac.com
SS-AMH95