Download Amana SS 4 Product specifications
Transcript
AMH95 G as F urnace up to 96% AFUE Standard Features • Heavy-duty MillionAir® stainless-steel, dual-diameter tubular heat exchanger • Stainless-steel secondary heat exchanger • Durable SureStart® Silicon Nitride igniter • Two-stage gas valve with technology that allows installer to activate the two-stage valve with the flip of a dipswitch • Self-adjusting feature automatically adjusts to high- or low-stage operation based on outside temperature without an outdoor temperature sensor • Color-coded low-voltage terminals with provisions for electronic air cleaner and 24-volt humidifiers • Control board stores last diagnostic codes in memory and outputs the fault history to a flashing red LED • Low continuous fan speed options offer quiet air circulation • All models comply with California NOx emissions standards Cabinet Features • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish • Designed for upflow or horizontal installation • Airtight solid bottom for side return applications and easy-cut tabs for effortless removal in bottom air inlet applications • Convenient left/right connection for gas/electric service • Coil and furnace fit flush for most installation Contents Nomenclature ....................................... 2 Product Specifications .......................... 3 Dimensions ........................................... 4 Airflow Data .......................................... 5 Wiring Diagrams ................................... 6 Accessories ............................................ 8 * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty (good for as long as you own your home) and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-AMH95 www.amana-hac.com Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. 11/12 Supersedes 4/12 Product Specifications Nomenclature A M H 95 70 3 B X AA 1 2 3 4,5 6,7,8 9 10 11 12,13 Brand A Amana® Brand Revisions Major and Minor Revisions Airflow Direction C Downflow/Horizontal D Dedicated Downflow H High Airflow K Dedicated Upflow M Upflow/Horizontal N Natural Gas X Low NOx Description V Two-Stage/Variable-speed H Two-Stage/Multi-speed S Single-Stage/Multi-speed A B C D AFUE 95 95% 9 90%+ 8 80% 045: 45,000 070: 70,000 090: 90,000 2 MBTU/h 115: 115,000 140: 140,000 www.amana-hac.com Maximum 3 4 5 NOx Cabinet Width 14” 17½” 21” 24½” CFM @ 0.5” ESP 1,200 1,600 2,000 SS-AMH95 Product Specifications Specifications AMH95 0453BXA AMH95 0703BXA AMH95 0704CXA AMH95 0904CXA AMH95 0905CXA AMH95 1155DXA Input ¹ 46,000 69,000 69,000 92,000 92,000 115,000 Natural Gas Output ¹ 44,200 66,300 66,300 88,400 88,400 110,500 LP Gas Output¹ 39,800 59,700 59,700 79,600 79,600 99,500 96.1 96.1 96.1 96.1 96.1 96.1 3 3 4 4 5 5 35 - 65 30 - 60 35 - 65 30 - 60 30 - 60 35 - 65 10” X 8” 10” X 8” 10” X 10” 10” X 10” 11” X 10” 11” X 10” Horsepower @ 1750 RPM ⅓ ⅓ ½ ½ ¾ ¾ Speed 4 4 4 4 4 4 Vent Diameter ³ 2” 2” 2” 2” 3” 3” Heating Capacity AFUE ² Available AC @ 0.5” ESP Temperature Rise Range (°F) Circulator Blower Size (D x W) No. of Burners Disposable Filter Size (in2) 2 3 3 4 4 5 580 580 770 770 960 960 9.4 9.4 13.8 13.8 13.2 13.2 15 15 15 15 15 15 120 123 125 144 146 163 Electrical Data Min. Circuit Ampacity 4 Max. Overcurrent Device (amps) Ship Weight (lbs) 5 Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level. Low-fire rate is 75% of high-fire rate DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. 1 2 Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½” FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-AMH95 www.amana-hac.com 3 Product Specifications COMPONENT IDENTIFICATION Dimensions GMH95*****XA* AIR DISCHARGE AIR DISCHARGE 19 7/8” AIR INTAKE PIPE 2" PVC RIGHT SIDE DRAIN LINE HOLES 1 1/2 2 1 5/8 1 UNFOLDED FLANGES UNFOLDED FLANGES FOLDED FLANGES FOLDED FLANGES RIGHT SIDE VIEW Model AMH950453BXA A B C D E 17½” 16” 13⅛” 12⅛” 13⅝” AMH950703BXA 17½” Cabinet Size E12⅛” 13⅝” 16” 17½” 16” 17½” 16” 17½” 19⅜” 20⅞” AMH950704CXA A 16” 21” AMH950904CXA GMH950453BXA* 21” GMH950703BXA* AMH950905CXA 21” AMH951155DXA B C13⅛” 19½” 24½” GMH950704CXA* 19½” 17-1/2 19½” 23” 21 D 16⅛” 16⅛” 16 12-15/16 19-1/2 15-15/16 16⅛” 12-1/8 13-5/8 16 17-1/2 20⅝” GMH950904CXA* Notes: • Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter,GMH950905DXA* depending upon furnace input, number of elbows, length of run, and installation (1 or 2 pipes). 24-1/2 20-7/8 19-3/8 23 20-7/16 The optional combustion air pipe is GMH951155DXA* dependent on installation/code requirements and must be 2” or 3” diameter PVC. • Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. All dimensions are in inches. • Conversion kits for high-altitude natural gas operation are available. Contact your Amana distributor or dealer for details. • Installer must supply the following gas line fittings, according to which entrance is used: Left: One 90º street elbow; one 2½” pipe nipple; one 90º elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve • Installations using a bottom return: Failure to unfold flanges will reduce airflow area by approximately 18%. This could result in performance andAirflow noise issues. NOTE: area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues. Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0” 0” 1” C 0” 1” Horizontal 6” 0” 1” C 0” 4” 6 C = If placed on combustible floor, the floor MUST be wood ONLY. Notes • For servicing or cleaning, a 24” front clearance is recommended. • Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. • In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • Approved for line contact in the horizontal position. 4 www.amana-hac.com SS-AMH95 Product Specifications Airflow Data (CFM & Temperature Rise vs. External Static Pressure) Model Motor Speed Tons AC¹ External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High Med AMH95 0453BXA Med-Lo Low 3 2.5 2 1.5 1,352 1,214 997 757 29 32 40 52 1,318 1,172 994 753 30 34 40 52 1,260 1,123 960 734 31 35 41 54 1,202 1,064 923 704 33 37 43 56 1,128 1,012 884 674 35 39 45 59 1,044 938 817 620 955 859 741 524 853 741 611 438 High Med AMH95 0703BXA Med-Lo Low 3 2.5 2 1.5 1,449 1,192 981 750 41 50 61 79 1,409 1,172 962 730 42 51 62 81 1,326 1,141 943 714 45 52 63 83 1,273 1,094 917 692 47 54 65 86 1,201 1,046 888 657 49 57 67 90 1,194 973 830 620 1,136 904 764 570 1,018 793 665 502 High 4 2,069 29 1,965 30 1,871 32 1,756 34 1,661 36 1,549 1,415 1,275 3.5 1,752 34 1,724 34 1,667 36 1,603 37 1,488 40 1,402 1,290 1,082 3 1,437 41 1,437 41 1,417 42 1,369 43 1,320 45 1,256 1,140 984 2.5 1,184 50 1,177 50 1,161 51 1,132 52 1,095 54 1,047 928 837 High Med AMH95 0904CXA Med-Lo Low 4 3.5 3 2.5 1,970 1,713 1,439 1,183 40 46 55 67 1,874 1,650 1,412 1,155 42 48 56 69 1,757 1,572 1,370 1,122 45 50 58 71 1,667 1,510 1,327 1,108 48 52 60 72 1,566 1,418 1,260 1,062 51 56 63 75 1,431 1,313 1,166 1,011 1,334 1,211 1,078 931 1,182 1,079 956 816 High Med AMH95 0905CXA Med-Lo Low 5 4 3.5 3 2058 1718 1502 1305 39 47 54 62 1997 1685 1464 1277 40 48 55 63 1928 1632 1429 1253 42 49 56 64 1852 1586 1380 1212 43 51 58 66 1777 1520 1319 1175 45 53 61 69 1682 1458 1272 1127 1600 1369 1200 1081 1487 1281 1137 1010 High Med AMH95 1155DXA Med-Lo Low 5 4 3.5 3 2,134 1,678 1,453 1,259 46 58 68 78 2,103 1,643 1,440 1,239 47 60 68 79 2,029 1,643 1,426 1,220 48 60 69 80 1,941 1,577 1,363 1,181 51 62 72 83 1,906 1,527 1,349 1,159 51 64 73 85 1,818 1,489 1,314 1,118 1,733 1,423 1,253 1,082 1,625 1,339 1,205 1,015 Med AMH95 0704CXA Med-Lo Low ¹ at 0.5” ESP Notes • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. • The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. SS-AMH95 www.amana-hac.com 5 4 9 8 7 BL 2ND STAGE DELAY HEAT OFF DELAY 12 11 10 YL GY FS 2 HEAT-H JUNCTION BOX .100 DOOR SWITCH WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. WH AUTO RESET PRIMARY LIMIT CONTROL PU BL C 2 CIRCUIT CONNECTOR HOT SURFACE IGNITER PK 0 GND C 3 2 JUNCTION BOX BR OR GAS VALVE (HONEY WELL) GND FLAME SENSOR DISCONNECT 2 2 FLASHES = PRESSURE SWITCH STUCK CLOSED HI VOLTAGE (115V) HI VOLTAGE FIELD 3 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE 7 7 FLASHES = LOW FLAME SIGNAL 8 8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY LOW VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION 4 LOW VOLTAGE (24V) = CONTROL FAILURE = SYSTEM LOCKOUT (RETRIES EXCEEDED) 4 L BK 1 FLASH EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE A REV ZONE 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) ECN 4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED. 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 3 NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY. 0904251 0140F00663 REV. A N WH 1 PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. GR STEADY ON = NORMAL OPERATION COLOR CODES: YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK 6 BL OFF C N RD MANUAL RESET ROLLOUT LIMIT CONTROL(S) ( SINGLE CONTROL ON 45K BTU ) 24 VAC HUMIDIFIER FRONT COVER PRESSURE SWITCH N C O PM 1 GY GY HI GND TO 115 VAC / 1Ø / 60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE ID BLOWER PRESSURE SWITCH L TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE OR WH DISCONNECT 5 YL OR ELECTRONIC AIR CLEANER LINE-H WH WH INDUCED DRAFT BLOWER 6 10.500 BK LINE NEUTRALS BR EAC-H GND CIRCULATOR BLWR HI -H AT HE MANUAL RESET AUXILIARY LIMITS (1) IN UPFLOW BLOWER DECK (2) IN C'FLOW BLOWER HOUSING BURNER COMPARTMENT N O COOL-H PU BLOWER COMPARTMENT RD HE LO AT -H INTEGRATED CONTROL MODULE INTEGRATED CONTROL MODULE OR CAPACITOR ID BLWR IND OR WH YL GY OR BL BR HOT SURFACE IGNITER IGN BK CIRCULATOR BLOWER 115 VAC FS PK RD MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 45K BTU) 24 VAC FLAME SENSOR WH WH BR RO1 (5) XFMR-H YL BK (HI) BL (MED) OR (MED LOW) RD (LOW) MANUAL RESET AUXILIARY AUTO RESET LIMIT CONTROLS PRIMARY LIMIT CONTROL RO2 (11) 40 VA TRANSFORMER WH GR RD WH R BK LINE-H SEE NOTE 4 GND HLO (1) 7 COOL-H HLI (7) W TH (3) 1 115 VAC HOT AND PARK TERMINALS NO C PSO (4) PK XFMR-H SEE NOTE 6 DIAGNOSTIC LED PS (10) TO MICRO Y BR RD GY OR * FACTORY SETTINGS SHOWN GR OR OR 115 VAC NEUTRAL TERMINALS * * * OR G ⚡ 1 5 ID BLOWER PRESSURE SWITCH 8 2 C NO High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. BK OFF GY PK 3 6 INTEGRATED CONTROL MODULE 24V THERMOSTAT CONNECTIONS OR FUSE PM FRONT COVER PRESSURE SWITCH BK WH BK MODE GAS HI VALVE MVL(2) C W Y ON C MVH (12) ⚠ R GND GND (8) MVC (9) Warning 40 VA TRANSFORMER INTEGRATED CONTROL MODULE HUMIDIFIER TR (6) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. G 9 24 VAC C ( 6.190 ) GY 115 VAC 24V THERMOSTAT CONNECTIONS BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN) OR 24 VAC HUMIDIFIER (.125) (SEE NOTE 4) NOTES: 1. MATERIAL: FLEXMARK PM 200 WHITE TC-245 L-23 SPEC 50K-8 Wiring Diagrams with Honeywell Valve F E D C B Product Specifications www.amana-hac.com SS-AMH95 2 I Product Specifications Wiring Diagrams with White-Rodgers Valve INTEGRATED CONTROL MODULE HUMIDIFIER C GND GAS HI VALVE R G W Y BK WH BK BK OR FUSE INTEGRATED CONTROL MODULE ON OFF 2ND STAGE DELAY MODE * * 2 1 6 5 4 8 7 BL 11 10 YL HOT SURFACE IGNITER COOL-H CIRCULATOR BLWR OR HI -H AT HE BR EAC-H PU BLOWER COMPARTMENT ELECTRONIC AIR CLEANER LINE-H JUNCTION BOX DOOR SWITCH GY BURNER COMPARTMENT WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. GND BK WH WH INDUCED DRAFT BLOWER WH AUTO RESET PRIMARY LIMIT CONTROL INTEGRATED CONTROL MODULE L HE O AT -H OR CAPACITOR LINE NEUTRALS INTEGRATED CONTROL MODULE GR WH YL ID BLWR IND OR BL BK RD YL CIRCULATOR BLOWER BR WH WH BR 115 VAC IGN WH PK RD MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 45K BTU) 24 VAC FLAME SENSOR GY BK (HI) BL (MED) OR (MED LOW) RD (LOW) RO1 (5) XFMR-H GY WH ID BLOWER PRESSURE SWITCH 40 VA TRANSFORMER BK LINE-H SEE NOTE 4 GND NO C AUTO RESET PRIMARY LIMIT CONTROL RO2 (11) FS 1 HEAT-H HLO (1) R GR PU 2 DISCONNECT L GND N TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE PU BL RD YL OR N O OR C PK WH HUMIDIFIER 2 CIRCUIT CONNECTOR PM HOT SURFACE IGNITER HI 2 C 3 GY 1 N O C FRONT COVER PRESSURE SWITCH GY GND BR (HONEYWELL) STEADY ON = NORMAL OPERATION JUNCTION BOX 1 FLASH = SYSTEM LOCKOUT (RETRIES EXCEEDED) 2 N WH GND FLAME SENSOR L BK DISCONNECT LOW VOLTAGE (24V) = CONTROL FAILURE 1 WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. GR OR GAS VALVE OFF EQUIPMENT GND LOW VOLTAGE FIELD FIELD GND 2 FLASHES = PRESSURE SWITCH STUCK CLOSED HI VOLTAGE (115V) FIELD SPLICE HI VOLTAGE FIELD SWITCH (TEMP.) 3 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 4 FLASHES = OPEN HIGH LIMIT 5 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE 7 7 FLASHES = LOW FLAME SIGNAL 8 8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY C BL TO 115 VAC / 1Ø / 60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE 0 RD MANUAL RESET ROLLOUT LIMIT CONTROL(S) ( 24 VAC SINGLE CONTROL ON 45K BTU ) ID BLOWER PRESSURE SWITCH COLOR CODES: YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED 0140F01027-B SS-AMH95 JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION ⚡ PSO (4) HLI (7) W BR 115 VAC NEUTRAL TERMINALS XFMR-H SEE NOTE 6 115 VAC HOT AND PARK TERMINALS COOL-H OR C NO FRONT COVER PRESSURE SWITCH PS (10) TO MICRO Y TH (3) OR RD GY FS G OR 9 OR * FACTORY SETTINGS * SHOWN GY PU 12 GY HEAT OFF DELAY DIAGNOSTIC LED 3 MVL(2) 24V THERMOSTAT CONNECTIONS 115 VAC 24V THERMOSTAT CONNECTIONS C 40 V A TRANSFORMER C High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 24 VAC MVH (12) AUXILIARY LIMIT CONTROLS BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN) GY Warning OR 24 VAC HUMIDIFIER PM ⚠ GND (8) MVC (9) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. TR (6) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED. 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) www.amana-hac.com 7 Product Specifications Accessories Model Description AMH95 0453B** AMH95 0703B** AMH95 0704C** AMH95 0904C** AMH95 0905C** AMH95 1155D** LPM-06 LP Conversion Kit (Springs & Orifice) √ √ √ √ √ √ LPLP03 LP Gas Low Pressure Kit √ √ √ √ √ √ FTK04 Twinning Kit √ √ √ √ √ √ ASAS Electronic Air Cleaners √ √ √ √ √ √ AMU Media Air Cleaners √ √ √ √ √ √ HANG11 High Altitude Natural Gas Kit 1 1 1 1 --- 1 HANG12 High Altitude Natural Gas Kit 2 2 2 2 --- 2 HALP10 High Altitude LP Gas Kit 3 3 3 3 --- 3 HAPS27 High Altitude Pressure Switch Kit 3 3 3 3 --- 3 EFR01 External Filter Rack √ √ √ √ √ √ DCVK-20 Horizontal/Vertical Concentric Vent Kit (2”) √ √ --- --- --- --- DCVK-30 Horizontal/Vertical Concentric Vent Kit (3”) √ √ √ √ √ √ 017K00000S Flush-mount Vent Kit √ √ √ √ √ √ Notes √ Indicates available for this model 2 Indicates 9,001’ to 11,000’ altitude 1 Indicates 7,001’ to 9,000’ altitude 3 Indicates 7,001’ to 11,000’ altitude • All installations above 7,000’ require a pressure switch change. • For installation in Canada, gas furnaces are certified only to 4,500’. Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA. 8 www.amana-hac.com SS-AMH95