Download Aiphone JA-2MECD Specifications

Transcript
C
o
n
t
e
n
t
s
AUDIO ENTRY SECURITY
COLOR VIDEO ENTRY SECURITY
1 1
Two-Wire Electric Lock Door Phone
3
1 1
Chime Tone Intercom
5
1 1
Chime Tone Intercom
7
1 1
Chime Tone Intercom
9
1 3
Chime Tone Intercom
11
2 3
Chime Tone Intercom
13
2 6
Chime Tone Intercom
15
1 1
Hands-free Color Video Intercom
2 3
Hands-free Color Video Intercom, Picture Memory
2 3
Hands-free Color Video Intercom
2 3
Hands-free Color Video Intercom, PanTilt, Picture Memory
1 1
Video Sentry Color Tilt
1 3
Video Sentry Color Tilt
3 5
Video Sentry Color Tilt
JF-1MD
JF-2MED
JB-2MED
JA-2MECD
KCS-1ARD
KC-1GRD
KB-3MRD
DA-1AS
27
C-123L/A
28
TCS-MH
29
IE-1AD(U)
30
IE-1GD(U)
31
IE-2A2D(U)
32
IE-8MD
33
Audio Door Stations
34
Color Video Accessories
KC-32EU
JBW-BA, RY-3DL, KAW-D, MCW-S
17
18
MULTI-UNIT ENTRY SECURITY
Hands-free Color Video Bus Apartment System
GH SYSTEM
BLACK & WHITE VIDEO ENTRY SECURITY
1 3
Wide Angle Video Sentry
2 3
PanTilt Video Sentry
1 6
PanTilt Video Sentry
3 8
Master Sentry
35~48
35
System outline
MK-1GD
19
MK-2MCD
21
5 48 Standard System configuration
37
16 500 Expanded System configuration
38
39
42
43
45
46
47
48
Entrance station
MY-CU & IE-8MD
23
Residential station
Security guard station, Control unit
LEF-C Video
24
GH lift control adaptor
B&W Video Accessories
GH CCTV camera interface adaptor for Reception
MK-2DA, MK-2DG, KC-32EU
MYW-BA, RY-3DL, IER-2
25
26
Cabling (standard)
Wiring (standard)
Bus Apartment System
49~59
GF SYSTEM
Two-Wire Bus System
5 100 GF Audio
49
Four-Wire Common B&W Video System
5 100 GF Audio/Video
51
Two-Wire Bus System
8 4,800 GF Multi-Tower
Example
2
DOOR
ENTRANCE
MASTER
SERVICE SIDE
STATION
3
ROOM
RESIDENCE
SUB
PUBLIC SIDE
53
GF Components
1 4
55
Two-Wire Electric Lock Door Phone
DA-4DS
60
Audio Entry Security
1 58 VC-M
SINGLE-FAMILY HOME
MULTI-TENANT
COMMERCIAL BUILDING
FACTORY
61
OFFICE
SCHOOL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1 1
Open Voice Intercom
1 3
Open Voice Intercom
11
LEM-1DL
LEM
LEF
Open Voice Intercom
3 8
Open Voice Intercom
25
COLOR VIDEO ENTRY SECURITY
64
Open Voice Intercom
3 8
1 3
63
LEF-C
65
67
LEF & MYW-P1L/P3L
68
LE Sub stations & Accessories
69
BLACK & WHITE VIDEO ENTRY SECURITY
Handset Intercom
AT-406
70
Handset Intercom
TD-H/B lTD-Z/A
71
Handset Intercom
1 24 TD-H/B & MY-CU
90
73
Handset Intercom
YAZ-90-3W
AUDIO ENTRY SECURITY
74
Integrated Security & Communication System
8 120 AX
Security Intercom
64 1,024 Commercial
AI-900
1 1
75
79
Security Window Intercom
IMU-100
83
MULTI-UNIT ENTRY SECURITY
Master / Sub Intercom
1 120 NEM
85
Master / Sub Intercom
2 100 TC-M
10 1
Master / Sub Intercom
10 1
Master / Sub Intercom
60
Market-Com
1 3
TC-M & TB-AD10
TC-M & TB-ADM10
MC-60/4A
87
88
89
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
90
Mid-Power Intercom
MP-S
91
High-Power Intercom
2 10 AP-M
92
Nurse Call
1 80 NHX
93
Nurse Call
1 120 NEM
99
ACCESSORIES & POWER SUPPLIES
ACCESSORIES & POWER SUPPLIES
Accessories
IER-2, RY-AC/A, TAR-3, MAW-B
Power Supplies
104
106
COMMUNICATION DISTANCE & INDEX
Communication Distance
Index
108
109
COMMUNICATION DISTANCE & INDEX
Communication Systems
for business, home and industry
Established In 1948
Aiphone has become the most respected and reliable brand of communication systems in the world.
With headquarters in Nagoya and manufacturing in Toyota City, Central Japan, we export to over 60 countries.
We expand ourselves along with a North American marketing, sales and distribution center near Seattle,
Washington, and a European sales and distribution center Lisses-Evry, France.
Systems For Every Application
Aiphone products range from simple do-it-yourself door answering units to sophisticated video entry security
systems, complex microprocessor-based commercial systems, and luxury condo/apartment
security/communication systems. They are unrivaled in design simplicity, technical excellence and reliability.
With over 30 standard systems, and additional manufacturing by special order, we can create a system for
virtually any intercom application.
Designed To Last
Every Aiphone system is the result of painstaking attention to detail: contemporary European style design,
the finest quality hardware and circuitry, engineered, built and 100% pre-tested for sustained trouble-free service.
ISO 9001
Aiphone is the first intercom manufacturer worldwide to receive ISO 9001 certification, and the only one selling
in North America, An agency representing the International Standards Organization (ISO), headquartered
in Geneva, Switzerland, graded Aiphone against guidelines for design and development, production, and product
inspection and testing. ISO 9001 standards provide an immediate recognition of product quality almost
anywhere in the world.
Winner Of The Deming Prize
Aiphone is the first and only intercom manufacturer to win the Deming Prize, the highest international award
for quality control. Named in honor of Dr. W. Edwards Deming, the award honors firms worldwide which
advance and maintain manufacturing quality.
Acquisition of ISO 14001
ISO's Environmental Standards are a series of voluntary standards and guideline reference documents which
include environmental management systems, eco-labeling, environmental auditing, life cycle assessment,
environmental performance evaluation, and environmental aspects in products standards. In early 1998, our
management team determined to acquire ISO-14001 approval as a company-wide project, and working
committee was established at the same time. Since then, with our ongoing efforts and practice about
environmental management standards, we have succeeded to acquire the approval.
Aiphone excludes the use of prohibited material from the product according to RoHS directive (2002/95/EC).
Therefore, as of July 1, 2006, all the Aiphone products imported in EUwill be fully complied with
the RoHS directive.
ISO 9001 Certified
ISO 14001 Certified
JQA-0291
JQA-EM0453
AIPHONE CO., LTD.
Toyota Factory
AIPHONE CO., LTD.
Deming Prize
ENVIRONMENTAL REPORT
We will contribute to building a sustainable society while cultivating
communications with a wide spectrum of our stakeholders.
Basic Environmental Philosophy
Revised October 1, 2005
Based on our business philosophy of "Be Responsible for your job and don't
cause of problems for others," we carry out our activities while harmonizing
conservation of the global environment with our business operations.
Environmental Policy
The AIPHONE group aspires to be enterprises capable of making
contributions to society by using communication and security technologies,
conducting our environmental activities as follows:
(1) We will strive to minimize environmental loads to conserve the global environment in our
activities of developing, producing, selling, and servicing our products.
(2) We will make our goals and objectives clear in our business activities, continuously
evaluating the following items and thus improving them:
a)
We will aim to become a recycling society and make efforts to promote the 3R's (Reduce,
Reuse, and Recycle) and minimize waste.
b)
We will not use harmful substances that cause environmental contamination.
c)
We will strive to conserve energy to prevent global warming.
(3) We will conform to environment-related laws, regulations, and conventions while
establishing voluntary standards to conserve the environment.
(4) Placing great value on communication, we will promote the manufacture of products friendly
to both humans and the environment.
(5) We will conduct environmental audits in an effort to maintain and improve our environment
management system.
(6) We will make our environmental policy thoroughly known to our employees and all those
who work together with us.
(7) We will publicize this environmental policy to the general public.
Certificate of acquisition of
ISO 14001 accreditation
This report is also posted on our website:
http://www.aiphone.co.jp/english/
1
Hands-free Color Video Intercom
DOOR
Features
ROOM
1
• One door & two monitors (3-1/2 inch); room to room
communication is not available
• Total hands-free communication, auto-voice actuation
• Streamlined & Thin design, only 27 mm thickness
• Vandal resistant video door stations are available
• White LED illumination turns on in low-light conditions
1+1 JF-1MD
Door station
Master station
COLOR VIDEO ENTRY SECURITY
2
IER-2
2
2
PT
Call extension
m P.104
PS18
JF-DV
Vandal-resistant video
door station, surface mount
JF-1MD
Master station w/color monitor
or
or
JF-DA
JF-DVF
Standard video
door station
Vandal-resistant video
door station
flush mount
Power supply PS-1820S PS-1820UL PS-1820 m P.107
Communication network
Wiring
100m / 1.0mma
JF-DV
JF-1MD
JF-1FD
JF-1MD
2
6
JF-1SD
6
JF-DV
DOOR
A1
A2
A1
A2
M
Electric door strike
JF-1SD
PT
CALL EXT
IER-2
S
S
1
E
SUB
SUB
B1
B2
B1
B2
DOOR
RELEASE
DOOR
RELEASE
L
L
L
L
DC18V
DC18V
JF-1FD
PS18
(BR)
(RD)
Room-to-room communication is not available.
BR: Brown RD: Red
(BR)
External
device
(RD)
PRESS TALK
PRESS TALK
ON OFF
ON OFF
PS18
External
device
: PS-1820/S/UL PT : AC Transformer
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
3
•
•
•
•
•
•
Instant voice call-in with image
Visual monitoring with audio for 1 minute
Press-to-talk operation available
Talk LED lights in red while speaking
Optional audio sub station (JF-1SD)
Option - Option button, press-to-talk setting
Lineup
Sub station
JBW-BA
Long distance adaptor
m P.18
*Max. 300m away from
Master/sub to Door.
JF-1FD
Sub station
w/color monitor
or
6
JF-1SD
Audio sub
station
COLOR VIDEO ENTRY SECURITY
6
KAW-D
30k angled box
m P.18
Boxed sets
JFS-1AD: JF-1MD, JF-DA
JFS-1ADV: JF-1MD, JF-DV
JFS-1ADF: JF-1MD, JF-DVF
Add appropariate power supply
Unit dimensions
Electric door strike
(locally available)
Image view area
JF-DA, JF-DV, JF-DVF
JF-1MD, JF-1FD
JF-1SD
(2)
210
179
(1)
27
135
JF-DV
82
JF-DVF
27
(3)
65cm 70cm
65cm
50cm
95cm
40
5.5
JF-DA
131
209
173
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only)
Specifications (JF-1MD)
99
98
25
135
29
108.5
120
88
Power source
Power supply
Consumption
Calling
Communication
JBW-BA
83.5
IER-2
45
40
122.5
61
Video monitor
Scanning line
Night viewing
Door release
Wiring
Wiring distance
18V DC
PS-1810DIN
Max. 450mA (JF-1MD). Max. 300mA (JF-1FD)
Chime. Image & audio, approx. 45 sec.
Approx. 1 min.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
3-1/2 inch direct-view TFT color LCD.
525 lines
Up to 30cm from camera, with white LED projected,
background beyond 30cm cannot be seen.
24V AC/DC, 500mA (N/O dry closure contact)
Door to master: 2-cond., mid cap, solid, non-shielded.
Master to sub: 6-cond., mid cap, solid, non-shielded.
Master/Sub (farthest room station) to door:
50m (0.65mma) 100m (1.0mma)
Master to IER-2: 75m (0.65mma) 150m (1.0mma)
4
Hands-free Color Video Intercom
Features
DOOR
ROOM
2
3 JF-2MED
• Two doors & three monitors (3-1/2 inch)
• Total hands-free communication, auto-voice actuation
• Built-in picture memory; Record visitor both automatically &
manually
• Voice memo; Internal short voice messages can be recorded
and played back
Door station
Master station
COLOR VIDEO ENTRY SECURITY
4
2
2
2
IER-2
Call extension
m P.104
PT
JF-DV
Vandal-resistant video
door station, surface mount
JF-2MED
Master station w/color
monitor and picture memory
2
or
or
JF-D
JF-DA
JF-DVF
Vandal-resistant video
door station
flush mount
Audio only door
station
Standard video
door station
Power supply PS-1820S PS-1820UL
PS-1820 m P.107
Communication network
Wiring
100m / 1.0mma
100m / 1.0mma
JF-DV
JF-DV
JF-2HD
JF-2MED
2
2
4
JF-2SD
JF-2MED
or 2
A1
A2
NP
A1
A2
PS18
DOOR2
A1
A2
NP
SUB
B1
B2
CALL EXT
S
S
Electric door strike
M
(BR)
(RD)
JF-2SD
JF-2SD
or 2
2 IER-2
DOOR1
A1
A2
JF-2HD
4
JF-2SD
2
JF-DVF
M
JF-2HD
RELEASE
NP
IER-2
1
E
ON OFF
ON OFF
SUB
IN
SUB
OUT
SUB
IN
SUB
OUT
B1
B2
B1
B2
B1
B2
B1
B2
L
L
PT
PS18
DC18V
DC18V
JF-2HD
JF-DVF
Selective control of door release at communicating Door station.
All-Call the inside stations by voice, then talk individually.
RY-3DL Connection
JF-2MED
RY-3DL
Electric door strike
Picture memory
3/16
2006
02 DEC
18 : 45
L1
C1
L1
L2
C2
L2
• Plays 8 shots continuously so that you can see
them as a moving image.
Pause and frame-by-frame play are also available.
8 shots/picture
Electric door strike
PT
b1
b2
b3
L
D1
E
D2
OG
YE
GR
BR
RD
b1
b2
E
L
L
DC18V
PRESS THE TALK BUTTON TO END
BR: Brown RD: Red OG: Orange YE: Yellow GR: Green
PS18 : PS-1820/S/UL PT : AC Transformer
5
PS18
• Message for entrance; Outgoing messages can be recorded and sent
out at the door station manually
• Streamlined & Thin design, only 32 mm thickness
• Vandal resistant video door stations are available
• White LED illumination turns on in low-light conditions
• Visual monitoring with audio for 1 minute
• External sensor connectable for notifying and pictograph on monitor
• Instant voice call-in with image
•
•
•
•
•
•
•
•
Different chimes to indicate which door is calling
Press-to-talk operation available
All-Call for internal communication
Transfer of door station call to other inside stations
Selective door release control (with RY-3DL)
Optional audio sub master station (JF-2SD)
Audio door station in lieu of 2nd video door station
Option - Option button, Video signal (NTSC) output, External talk switch,
press-to-talk restriction
Lineup
Sub station
Sub master station
w/color monitor
Sub master station
w/color monitor
4
or
2
or
RY-3DL
JBW-BA
Door release
adaptor
m P.18
Long distance
adaptor
m P.18
*Max. 300m away
from Master to Door
2
JF-2SD
JF-2SD
Audio sub
master station
Audio sub
master station
KAW-D
COLOR VIDEO ENTRY SECURITY
JF-2HD
JF-2HD
30k angled box
m P.18
Boxed sets
JFS-2AED: JF-2MED, JF-DA
JFS-2AEDV: JF-2MED, JF-DV
JFS-2AEDF: JF-2MED, JF-DVF
Add appropariate power supply
Electric door strike
(locally available)
Unit dimensions
Image view area
JF-DA, JF-DV, JF-DVF
JF-2MED, JF-2HD
JF-2SD
JF-DV
27
(2)
135
JF-DVF
90
32
5.5
173
160
179
(1)
25
98
JF-DA
(3)
65cm 70cm
65cm
50cm
95cm
25
JF-D
209
131
130
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only)
Specifications (JF-2MED)
99
RY-3DL
29
108.5
JBW-BA
83.5
120
Power source
Power supply
Consumption
Calling
Communication
28.5
45
IER-2
88
40
140
135
98
122.5
Video monitor
Scanning line
Night viewing
61
74
42
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
Door release
Wiring
Wiring distance
18V DC
PS-1810DIN
Max. 400mA (JF-2MED). Max. 220mA (JF-2HD)
Chime. Image & audio, approx. 45 sec.
Approx. 1 min.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
3-1/2 inch direct-view TFT color LCD.
525 lines
Up to 30cm from camera, with white LED projected,
background beyond 30cm cannot be seen.
24V AC/DC, 500mA (N/O dry closure contact)
Door to master: 2-cond., mid cap, solid, non-shielded.
Master to sub: 4-cond., mid cap, solid, non-shielded.
Master to door: 50m (0.65mma) 100m (1.0mma)
Master to farthest sub: 50m (0.65mma) 100m (1.0mma)
Master to IER-2: 75m (0.65mma) 150m (1.0mma)
6
Hands-free Color Video Intercom
Features
DOOR
ROOM
2
3 JB Series
•
•
•
•
•
Door station
Two color doors, three inside monitor stations (3-1/2 inch LCD)
Total hands-free communication, auto-voice actuation
Built-in picture memory (JB-2MED only)
Instant voice call-in with image
Press-to-talk operation available
Master station
COLOR VIDEO ENTRY SECURITY
Picture
memory
4
2
IER-2
2
2
Call extension
m P.104
PT
Standard
Non-Picture
memory
JB-DV
PS18
Vandal-resistant video
door station, surface mount
or
JB-2MED
Master station w/color
monitor and picture memory
2
or
or
PS18
JB-2MD
Master station w/color
monitor
JA-D
JB-DA
JB-DVF
Vandal-resistant video
door station
flush mount
Standard video
door station
Power supply PS-1820S
PS-1820UL
Audio only door
station
PS-1820 m P.107
Communication network
Wiring
100m / 1.0mma
JB-DV
100m / 1.0mma
JB-2HD
JB-2MD,
JB-2MED
JA-2SD
JB-2MD, JB-2MED
JA-2SD
JB-2HD
DOOR1
A1
A1
2
A2
A2
NP
ON OFF
DOOR2
JA-2SD
A1
A1
A2
A2
SUB SUB
NP
SUB
IN OUT
B1
B1 B1
B2
B2 B2
IER-2
JB-DV CALL EXT
1
S
E
S
Electric door strike
RELEASE NP
BR
L
RD
L
DC18V
JB-2HD
JB-DVF
2
ON OFF
SUB
IN
B1
B2
JA-2SD
SUB
OUT
B1
B2
DC18V
PT
JB-2HD
PS18
JB-DVF
RY-3DL
Electric door strike
Selective control of door release at communicating Door station.
All-Call the inside stations by voice, then talk individually.
L1
C1
L1
Electric door strike
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
7
PT
L2
C2
L2
OG b1
YE b2
b1
b2
b3
L
D1
E
D2
JB-2MD,
JB-2MED
BR
RD
L
L
DC18V
PS18
BR: Brown RD: Red OG: Orange YE: Yellow
PS18
PT
: PS-1820S/UL
PT
: AC transformer
•
•
•
•
•
•
•
•
•
•
•
•
•
White LED illuminator turns on in low-light conditions
Door call-in LED lights in red or green
Different chimes to indicate which door is calling
All-Call for internal communication
Transfer of door station call to other inside stations
Optional audio sub station (JA-2SD)
Audio door station in lieu of JB video door station
Talk LED lights in red while speaking
Selective door release control (with RY-3DL)
Visual monitoring with audio for 30 seconds
Video output via supplied connector (NTSC)
Sensor connectable for alarming and pictograph on monitor (JB-2MED only)
Option - Foot talk switch
Lineup
Sub station
Sub master station
w/color monitor
Sub master station
w/color monitor
4
2
or
RY-3DL
JBW-BA
Door release
adaptor
m P.18
Long distance
adaptor
m P.18
KAW-D
o
Electric door
strike
(locally available)
2
or
JA-2SD
JA-2SD
Audio sub
master station
Audio sub
master station
Boxed sets
30 angled box
m P.18
COLOR VIDEO ENTRY SECURITY
JB-2HD
JB-2HD
JBW-D
o
15 angled box
JBS-2AD: JB-2MD & JB-DA
JBS-2ADV: JB-2MD & JB-DV
JBS-2ADVF: JB-2MD & JB-DVF
JBS-2AED: JB-2MED & JB-DA
JBS-2AEDV: JB-2MED & JB-DV
JBS-2AEDVF: JB-2MED & JB-DVF
Add appropriate power supply
Add appropriate power supply
Unit dimensions
Image view area
JB-DA, JB-DV & JB-DVF
JB-2MD, JB-2HD
JB-2MED
JA-2SD
(2)
(1)
(3)
70cm
65cm
210
175
175
65cm
50cm
43
115
43
115
82
40
95cm
(1) Initial horizontal view
(2), (3) When camera is turned up or down (JB-DA only)
5.5
JB-DA
JA-D
209
99
25
98
135
JBW-BA
29
40
28.5
98
RY-3DL
61
74
Calling
Communication
Video monitor
Scanning line
Night viewing
Door release
Wiring
140
108.5
120
122.5
88
Power source
Power supply
Consumption
45
83.5
IER-2
Specifications (JB-2MD, JB-2MED, JB-2HD, JA-2SD)
130
JB-DVF
131
27
173
JB-DV
42
Wiring distance
DC 18V
PS-1820S, PS-1820UL
Max. 670mA(JB-2MD). Max. 770mA(JB-2MED)
Max. 250mA(JB-2HD). Max. 120mA(JA-2SD)
Chime. Image & audio, approx. 30 sec.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 2 sec. or until talk LED turns on.
3-1/2 inch direct-view TFT color LCD.
525 lines
White LED projected up to 30cm from camera
AC 12V, 400mA (dry closure contact L, L)
4-wire parallel, station to station(non-twisted nor shielded).
Vinyl-jacket, PE insulation.
Master station ~ Door 50m(0.65mma) 100m(1.0mma)
Master station ~ farthest sub 50m(0.65mma) 100m(1.0mma)
Master station ~ IER-2 75m(0.65mma) 150m(1.0mma)
8
PanTilt Hands-free Color Video & Motion-sensor camera integration
Features
DOOR
ROOM
2
3 JA Series
• Two color PanTilt Camera door stations, three inside monitor
stations (4 inch LCD)
• Motion-sensor camera (max.2)
• Built-in picture memory (JA-2MECD only)
• Surveillance mode SET through sensor-cameras. Activates
monitor and internal alarming (& picture save in JA-2MECD)
Door station
Master station
COLOR VIDEO ENTRY SECURITY
Picture
memory
2
2
2
PT
4
2
IER-2
PT
2
Call extension
m P.104
PS24
Standard
or
Non-Picture
memory
JA-DGC
PanTilt color video door
station - semi-flush mount
JA-2MECD
2
PanTilt color monitor
master station,
picture memory
2
or
JA-DAC
PanTilt color video
door station - surface
mount
JA-D
Audio only door stationsurface mount
Power supply PS-2420S
PS-2420UL
JDW-C
Motion-sensor
camera
Motion-sensor
camera
JA-2MCD
PanTilt color monitor
master station
PS-2420 m P.107
Communication network
JA-DGC
PS24
JDW-C
Wiring
100m / 1.0mma
JA-2HCD
100m / 1.0mma
2
JA-DGC
JA-DAC
JDW-C
M
JDW-C
2
or
JA-2MECD
JA-2MCD
JDW-C
2
JA-2HCD
JA-2HCD
4
4
2
JA-2SD
JA-2SD
JA-2SD
Electric door
strike
A1
A2
JA-DAC
JA-D
1
2
NP
JDW-C
NP
A1
A2
JDW-C
M
or
NP
C1
C2
A1
B1
B1
B1
B1
B1
A2
B2
B2
B2
B2
B2
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
NP
C1
C2
JA-2HCD
DOOR2
DC24V
A1
+
+
+
A2
-
-
-
ADAPTER
-1
PS24
OFF
ADAPTER
-2
BR
PT
Electric door
strike
RD
OG
PT
YE
CALL
EXT
S
S
C1
C2
Electric door
strike
A
A
C1
C2
JDW-C
JA-2SD
M Door release activation
Hands-free voice-activated communication after TALK button is pressed.
9
DOOR1
or
JA-2MECD,
JA-2MCD
JA-DAC
NP
or 2
or 2
PT
JA-DAC
IER-2
NP
1
E
L1
L1
L2
L2
Wiring for JA-2SD; Two wires only. + / - wires are not necessary.
B1,B2: marked with SUB IN , SUB OUT PS24 :PS-2420S/DIN PT : AC transformer
BR: Brown RD: Red OG: Orange YE: Yellow
ON
•
•
•
•
•
•
•
•
•
•
•
•
Total hands-free communication, auto-voice actuation
Instant voice call-in with image
Press-to-talk available
White LED illuminator turns on in low-light conditions
All Call for internal communication
Transfer of door station call to other inside stations
Optional video (JA-2HCD) or audio (JA-2SD) sub stations
Audio door station in lieu of JA video door station
Talk LED lights in red while speaking
Visual monitoring with audio through all cameras
Two door release contacts for selective control
Options:
-Foot talk switch
-Manual Talk switch restriction
-RY-3DL for large door releases locally available
-Video output to video device (NTSC)
Lineup
Sub station
JA-2HCD
PanTilt color
monitor sub
master station
PanTilt color
monitor sub
master station
4
KAW-D
Electric door
strike
(locally available)
30k angled box
m P.18
JBW-D
15k angled box
2
or
or
2
JA-2SD
JA-2SD
Audio sub
master station
Audio sub
master station
COLOR VIDEO ENTRY SECURITY
JA-2HCD
JBW-BA
Long distance
adaptor
m P.18
Unit dimensions
Image view area
JA-DAC, JA-DGC
JA-2MECD
JA-2MCD, JA-2HCD
JA-DGC
50cm
220cm
210
210
172
90cm
180cm
130cm
180cm
65cm
42
JA-2SD
JA-D
98
40
JBW-BA
29
102
93.5
Calling
Communication
Video monitor
Scanning line
Night viewing
Door release
Wiring
108.5
83.5
120
122.5
88
Power source
Power supply
Consumption
28.5
82
IER-2
45cm 90cm
Max. pan-and-tilt view area: 90cm Vert., 180cm Horiz. (approx.)
JDW-C
210
98
44
47.5
50cm
Specifications (JA-2MECD, JA-2MCD, JA-2HCD, JA-2SD)
130
130
JA-DAC
12.5 19 37
182
160
115
42
160
61
Wiring distance
DC 24V
PS-2420S, PS-2420DIN
Max. 750mA(JA-2MECD).Max. 680mA(JA-2MCD).
Max. 290mA(JA-2HCD). Max. 120mA(JA-2SD)
Chime. Image & audio, approx. 30 sec.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 2 sec. or until talk LED turns on.
4 inch direct-view TFT color LCD.
525 lines
White LED projected up to 30cm from camera.
AC 12V, 350mA (dry closure contact L, L)
Parallel, station to station(non-twisted, non- shielded).
Vinyl-jacket, PE insulation.
Master station ~ Door 50m(0.65mma) 100m(1.0mma)
Master station ~ Motion sensor camera 50m(0.65mma) 100m(1.0mma)
Master station ~ farthest sub 50m(0.65mma) 100m(1.0mma)
Master station ~ IER-2 50m(0.65mma) 100m(1.0mma)
10
Video Sentry Color Tilt
DOOR
ROOM
1
1 KCS-1ARD
Door station
Features
• Clear and bright image with color TFT LCD monitor and DSP
video door station
• TILT camera control
• INSTANT ON audio & image of entry when called
Master station
COLOR VIDEO ENTRY SECURITY
2
2
2
PT
KC-DAR
PS24
Video door station
KC-1MRD
Master station
Power supply PS-2420S
PS-2420UL
Communication network
PS-2420 m P.107
Wiring
100m / 1.0mma
100m / 1.0mma
KC-1MRD
KC-DAR
IER-2
2
KC-DAR
KC-1MRD
NP
4-tone chime
M
Tilt camera control
2
2
A1
A2
M
N
H
A1
A2
S
S
+
–
1
E
N
Electric door strike
H
l Run audio/video wires in a separate jacketed cable from door release wires.
N : PS-2420S/UL H : AC transformer
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
11
• Hands-free monitoring audio & image of door
• Video door station's white LED illumination automatically turns on in
the darkness
• Locator LED backlight on CALL button
Lineup
KAW-D
Picture memory
unit
m P.17
30k angled box
m P.18
KA-DGR PANEL
Boxed sets
Electric door
strike
(locally available)
KCS-1ARD
JBW-BA
IER-2
Call extension
m P.104
Stainless steel
housing
for KC-DAR
Long distance
adaptor
m P.18
KC-1MRD boxed set
Unit dimensions
Image view area
KC-DAR
KC-DAR
KC-1MRD
124cm
★
235cm
130cm
83.5
195
83.5
140
105
COLOR VIDEO ENTRY SECURITY
KC-32EU
111cm
★
50cm
★
60cm ★
50cm
44
* approximate
185
JBW-BA
61
83.5
120
122.5
KA-DGR PANEL
142
KAW-D
83.5
55.4
107
105
Video monitor
Scanning lines
Image view area
29
4.5
Night viewing
Door release
Wiring
Distance
151
88
109
Specifications (KC-1MRD)
Power source
Power supply
Communication
108.5
IER-2
88
42
24V DC, 450mA. 50mA standby
PS-2420S, PS-2420UL
Door calls in w/4-tone chime & image, 30 sec. timed.
Lift handset to reply, 2-1/2 min. timed. In standby,
press MONITOR to view and hear door.
4 inch TFT color LCD
525 lines
Approx. 60cm horiz., 111~235cm vert.
at 130cm high and 50cm from camera.
White light projected up to 30cm from camera. The
background scene beyond 30cm cannot be seen.
12V AC, 400mA.
2 parallel wires to door, non-polarized.
KC-1MRD ~ door 50m(0.65mma) 100m(1.0mma)
KC-1MRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
30˚
12
Video Sentry Color Tilt
DOOR
ROOM
1
3 KC-1GRD
Door station
Features
•
•
•
•
VIDEO SENTRY COLOR TILT 1 door - 3 monitors
INSTANT ON door audio & video
All call type room calling
100m distance between monitors, looped
Master station
COLOR VIDEO ENTRY SECURITY
2
2
IER-2
2
2
Call extension
m P.104
2
PT
KC-DAR
Video door station
KC-1GRD
Master station
2
PS24
PS24
Power supply PS-2420S PS-2420UL
PS-2420 m P.107
Communication network
Wiring
100m / 1.0mma
100m / 1.0mma
IER-2
KC-1HRD
4-tone
chime
2
2
KC-1SD
KC-DAR
KC-1HRD
KC-1GRD
KC-DAR
NP
KC-1GRD
KC-1GRD
2
2
2
2
M
Tilt camera
2
2
N
N
H
(1)
M
KC-1SD
A
KC-1SD
KC-1HRD
A1
A2
A1 B1
A2 B2
+
-
N
KC-1HRD
B
A1 B1
A2 B2
A
+
+
-
N
Electric door strike
B
A1 B1
A2 B2
or
A
H
B
A1
S
S
1
E
A2
l Run audio/video wires in a separate jacketed cable from door release wires.
N : PS-2420S, PS-2420UL H : AC transformer
Cable
(1) All call type voice calling (from any).
Communication on handsets individually.
13
Vinyl jacketed, PE (polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
• TILT camera control
• Hands-free monitoring audio & image of door
• Video door station's white LED illumination automatically turns on in
the darkness
Lineup
Sub station
KC-1HRD
KA-DGR PANEL
KC-32EU
Stainless steel
housing
for KC-DAR
Picture memory
unit
m P.17
KAW-D
30k angled box
m P.18
Electric door
strike
(locally available)
JBW-BA
MCW-S
KC-1HRD
Sub master station
Sub master station
or
or
2
2
2
KC-1SD*
KC-1SD*
Audio sub
station
*Not available in Europe
Audio sub
station
*Not available
in Europe
Long distance
adaptor
mP.18
83.5
210
83.5
74
IER-2
83.5
120
140
83.5
JBW-BA
122.5
29
88
44
Power supply
Video monitor
Scanning lines
Communication
108.5
195
100
KC-DAR
KA-DGR PANEL
83.5
107
4.5
55.4
109
61
Image view area
Night viewing
Door release
Wiring
151
142
KAW-D
105
Power source
Consumption
KC-1SD
88
105
Monitor desk
stand
mP.18
Specifications (KC-1GRD)
Unit dimensions
KC-1GRD, KC-1HRD
185
COLOR VIDEO ENTRY SECURITY
2
42
Distance
30˚
24V DC
KC-1GRD: 450mA. 70mA standby.
KC-1HRD: 200mA. 50mA standby.
KC-1SD: 70mA. 50mA standby.
PS-2420S, PS-2420UL
4 inch TFT color LCD
525 lines
Door calls in w/4-tone chime, 30 sec. Hear and see
door instantly. Pick up at any station to reply, 2-1/2
min. timed. Recycle with MONITOR. Monitor hands-free
audio & image of door w/MONITOR. Press ALL CALL to
call the other w/pretone & voice. Lift either handset to
reply.
Approx. 60cm Horiz., 111~235cm Vert. at 50cm in
front of camera at 130cm high.
Up to 30cm from camera, with white LED projected.
Background scene beyond 30cm cannot be seen.
Contact rating: 12V AC, 400mA.
2 parallel wires to door, non-polarized.
2 wires in loop between monitors, plus 2 wires
separately run from power supply.
KC-1GRD ~ door 50m(0.65mma) 100m(1.0mma)
KC-1GRD ~ farthest sub 50m(0.65mma) 100m(1.0mma)
KC-1GRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
Image view area
KC-DAR
★
124cm
★
235cm
130cm
50cm
★
111cm
60cm★
50cm
* approximate
14
Video Sentry Color Tilt
Features
DOOR
ROOM
3
5 KB-3MRD
•
•
•
•
•
Door station
3 doors & 5 monitors w/TILT camera control.
INSTANT ON audio & image of door.
Selective calling or All Call.
Audio sub station in lieu of monitor.
Optional audio door at 3rd entry.
Master station
COLOR VIDEO ENTRY SECURITY
KB-DAR
Video door
station
2
2
2
PT
2
IER-2
2
KB-DAR
Video door
station
Call extension
m P.104
2
KB-3MRD
Master station
2
or
PS24
KB-DAR
Video door
station
IF-DA
Audio door station
Power supply PS-2420S
PS-2420UL
PS-2420 m P.107
Communication network
Wiring
200m / 1.0mma
KB-DAR
KB-DAR
KB-3HRD
4-tone
chime
Tilt camera control
M
KB-DAR
IER-2
KB-3HRD
2
NP
2
KB-3MRD
(1)
2-tone chime
Tilt camera control
KB-3HRD
KB-3MRD
2 KB-3HRD4
2
2
2
2
2
KB-3SD
KB-3HRD
2
2
M H
KB-DAR
2
A1
A2
KB-3SD
IF-DA
2A1 +
2A2 A1
A2
Electric door strike
Cable
Cable specified for wiring to both door and inside stations
l 0.65mma to 1.2mma dia.
l PE(polyethylene) insulation & vinyl jacketed cable
l Attenuation: less than -6.5dB at 10MHz./100m length.
l Solid copper conductor.
l Line impedance: c75 ohm (less than 100 ohm at the highest).
3A1
3A2
B
1A1 B1
1A2 B2
N
N
2
A
B
1A1 B1
1A2 B2
A
B
1A1 B1
1A2 B2
A
+
+
-
+
-
N
S
S
1
E
or
A
H
B
1A1 B1
1A2 B2
+
-
D1
E1
(1) Selective Call or All Call type voice calling (from any).
Communication on handsets individually.
2
KB-3SD
1A1 B1
1A2 B2
A1
A2
2
NN
N
A
8-tone chime
Tilt camera control
15
100m / 1.0mma
b1
b2
b3
E
B
A1 B1
A2 B2
(1)
l D1, E1 : for IF-DA door station instead of third KB-DAR.
l Run audio/video wires in a separate jacketed cable from door release wires.
N : PS-2420S, PS-2420UL H : AC transformer (1) External light control
•
•
•
•
Push chime or receiver volume control.
Optional selective door release with RY-3DL.
Hands-free monitoring audio & image of door.
Video door station's white LED illumination automatically turns on in
the darkness.
Lineup
Sub station
KB-3HRD
KB-3HRD
KB-3HRD
Sub master
station
Sub master
station
Sub master
station
Sub master
station
2
2
2
KC-32EU
RY-3DL
Picture memory
unit
m P.17
Door release
adaptor
m P.18
KA-DGR PANEL
Electric door
strike
(locally available)
or
2
2
KB-3SD
2
Stainless steel
housing
for KB-DAR
COLOR VIDEO ENTRY SECURITY
KB-3HRD
Audio sub
station
max. 2pcs
2
PS24
2
PS24
Unit dimensions
83.5
195
83.5
140
Power source
Consumption
44
KB-3SD
185
86
Power supply
Video monitor
Scanning lines
Communication
83.5
120
210
83.5
IER-2
29
88
100
Image view area
74
KAW-D
Night viewing
151
142
KA-DGR PANEL
107
42
109
MAW-B
30k angled box
m P.18
Auxiliary light
control relay
m P.105
Specifications (KB-3MRD)
KB-3MRD, KB-3HRD
KB-DAR
105
KAW-D
105
83.5
4.5
30˚
55.4
Distance
Image view area
KB-DAR
Door release
Wiring
24V DC.
KB-3MRD: max.710mA. 230mA standby.
KB-3HRD: max. 260mA. 80mA standby.
KB-3SD: max 85mA. 50mA standby.
PS-2420S, PS-2420UL
4 inch TFT color LCD
525 lines
Door calls in w/4-tone chime, 30 sec. Hear and see
door instantly. Pick up at any station to reply, 2-1/2
min. timed. Recycle with MONITOR. Monitor audio&
image of door hands-free w/MONITOR. Press a station
selector and call by voice. The called station replies
hands-free. Lifting handset, press ALL CALL button to
call the other stations w/pretone and voice.
Approx. 60cm Horiz., 111~235cm Vert. at 130cm high
& at 50cm in front of camera.
Up to 30cm from camera, with white LED projected.
Background scene beyond 30cm cannot be seen.
Contact rating: 12V AC, 400mA
2 parallel wires to door, non-polarized.
2 wires in loop between monitors, plus 2 wires
separately run from power supply.
KB-3MRD ~ door 100m(0.65mma) 200m(1.0mma)
KB-3MRD ~ farthest sub 50m(0.65mma) 100m(1.0mma)
KB-3MRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
★
124cm
★
235cm
130cm
50cm
★
111cm
60cm★
50cm
* approximate
16
Color Video Accessories
Picture memory unit
Features
l Easy add-on to present or new system, color or black & white
l 4 pictures in 1 frame (16 frames), 16, 32 or 60 individual picture save mode
l Max. 8 pictures stored in memory
Used for
KC-32EU
Picture memory unit
Programming
l Date / time position
l Date / time
l Save mode
Functions
l Auto Picture save
l Manual picture save (when viewing)
l Absence set
l Replay
l Store in memory
l Erase one or all pictures
Unit dimensions
KC-32EU
195
COLOR VIDEO ENTRY SECURITY
KC-1MRD, KC-1GRD, KB-3MRD
MK-1GD, MK-2MCD
83.5
80
54.5
Single-gang mounting
Wiring
IER-2
KC-DAR
KC-32EU KC-1GRD
2
2
KC-1GRD
KC-32EU
Master station Picture memory unit
2
M
N
H
2
2
2
2
N
A
A1
A2
NP
A1
A2
B1
B2
KC-1HRD
KC-1HRD
2
NP
1A1 B1
1A2 B2
N
B
1A1 B1
1A2 B2
A
NP
N
IER-2
Electric door
strike
S
S
1
E
N : PS-2410DIN, PS-2420DIN, PS-2420S H : AC transformer
Press REC button to view each 4-frame
picture individually.
Specifications (KC-32EU)
Power source
Power supply
Channel
Wiring
Wiring distance
MK-1GD
KC-32EU
Master station Picture memory unit
17
B
1A1 B1
1A2 B2
18V DC, 230mA.
24V DC, 160mA.
PS-1820S, PS-1820UL, PS-2420S, PS-2420UL
One video door per unit
2 parallel wires to door (NP).
2 wires to Master (Polarized).
KC-32EU to door 50m(0.65mma) 100m(1.0mma)
KC-32EU to master 25m(0.65mma) 5m(1.0mma)
KC-32EU to Power supply 10m(1.0mma) (20m w/1.2mma)
Long distance adaptor
Features
Wiring
250m / 1.2mma
JF-DV
Long distance adaptor
A1 B1
A2 B2
+
–
A1
A2
A1
A2
+
–
C
Cable
KC-1MRD, KC-1GRD
KC-32EUKC-1ARD/KC-1GRD
JA-2MECD, JA-2MCD
JB-2MD, JB-2MED
JF-1MD, JF-2MED
1.0mma to 1.2mma. Solid copper conductor PE insulation (not PVC).
Specifications
Power source
18VDC, 24VDC
PS-1820S, PS-1820UL, PS-2420S, PS-2420UL
of system or separate
120mA.
2 parallel wires to ea. door & master.
JA, JB, KC door~JBW-BA 100m~300m(1.2mma)
JBW-BA~JA, JB, KC master 50m(1.2mma)
JF door~JBW-BA 100m~250m(1.2mma)
JBW-BA~JF master/JF-1FD/JF-1SD 50m(1.2mma)
JBW-BA~PS 50m(1.2mma)
Unit dimensions
Current consumption
Wiring
Distance
108.5
JBW-BA
61
122.5
JF-2MED
JBW-BA
Used for
JBW-BA
50m / 1.2mma
COLOR VIDEO ENTRY SECURITY
l When JA, JB, KC color video
door station is more than 100m
to max. 350m away, or JF color
video door station is more than
100m to max. 300m away.
l One required for each door
station.
Selective door release adaptor
Wiring
Features
l Selective door release with one
button
l Door release contacts release
the door where communication
is established.
l Normally open contacts for
electric strike. Normally closed
contacts to work with magnetic
locks.
Electric door strike
Electric door strike
L2
C2
L2
Electric door strike
Door release adaptor
KB-3MRD
CN12
GR
BL
PL
CN11
OG
YL
b1
b2
b3
L
D1
E
D2
L3
C3
L3
Used for
RY-3DL
RY-3DL
L1
C1
L1
N
H
KB-3MRD, JB-2MED, JB-2MD
MK-2MCD, IE-2AD(U)
JF-2MED
GR : Green BL : Blue PL : Purple OG : Orange YL : Yellow
H : AC transformer N : PS2420S, PS-2420UL
Unit dimensions
Specifications
Power source
Power supply
Relay contacts
140
RY-3DL
Wiring distance
74
42
12~24V DC, 30mA. 12~16V AC, 60mA.
PS-2420S, PS-2420UL; PS-1820S, PS-1820UL; PS-1225S/UL; AC trans.
Normally open output. 1A at 50V AC. 1A at 30V
DC (for other types, use matching relay)
Master to RY-3DL 50m(0.65mma) 100m(1.0mma)
RY-3DL to Electric door strike 50m(0.65mma) 100m(1.0mma)
30kangle box
Features
Image view area
l 30k Angle Box for mounting video door station
to position door camera to view visitors better.
l Designed for 1-gang surface mounting.
KAW-D
30 Used for
KC-DAR, KB-DAR, MK-DH
m
50c
Unit dimensions
KC-DAR
★
m
60c
142
KAW-D
KAW-D
83.5
*Figure is approximate.
30k angled box
107
105
4.5
55.4
30˚
Desk-top stand
Used for
MCW-S
Monitor desk
stand
MK-1GD, MK-1HD
MK-2MCD, MK-2HCD
KC, KB monitors
18
Wide Angle Video Sentry
DOOR
ROOM
1
Features
3 MK-1GD
•
•
•
•
Door station
Single-door, three-monitor system with door release
Instant voice call-in with image
Internal handset communication. All call type voice calling
Transfer of door call-in. (Image of caller remains on)
Master station
2
4
2
IER-2
2
Call extension
m P.104
BLACK & WHITE VIDEO ENTRY SECURITY
PT
MK-DV
PS18
Video door station
or
MK-1GD
Master station
or
MK-DH
MK-DVF
Video door station
Video door station
Power supply PS-1820S PS-1820UL PS-1820 m P.107
Communication network
Wiring
200m / 1.0mma
MK-DV
MK-1HD
M
H
4-tone
chime
A1
A2
NP
MK-2SD
MK-1HD
Electric door
strike
Instant voice calling w/image. All call with pre-tone/voice.
Internal communication on handsets
4
4
MK-1GD
M
MK-1HD
MK-1HD
2
2
MK-2SD
MK-DV
75m / 1.0mma
IER-2
MK-1GD
H
2
U
DOOR SUB
B1
A1
A2
B2
NP
CALL EXT IER-2
1
S
E
S
RLSE. DC18V
+
L
L
P
U
SUB
IN OUT
B1
B1
B2 B2
NP
DC18V
IN OUT
+
+
DC18V
IN OUT
+
+
P
SW1
OFF
ON
MK-2SD
4
SUB
SUB
B1
B2
DC18V
+
SW1
OFF
l MK-2SD may be wired in the same manner as MK-1HD.
U : PS-1820S, PS-1820UL
H : AC transformer SW1-ON Terminated
19
SW1
MK-2SD
4
NP
P
SUB
IN OUT
B1 B1
B2 B2
NP
P
B1
B2
DC18V
+
SW1
ON
• Fixed camera, wide angle viewing
• Infrared LED's projected on callers at 50cm in the darkness
Lineup
Sub station
4
MK-2DA
MK-2DG
Two-call video
door station
m P.25
or
MK-1HD
Sub master
station
Sub master
station
2
2
MK-2SD
MK-2SD
Audio sub
master station
Audio sub
master station
Electric door
strike
(locally available)
KAW-D
KC-32EU
MKW-P
Picture memory
unit
m P.25
MK-DV Gang box
mounting plate
30k angled box
m P.18
Boxed sets
MKS-1GD: MK-1GD & MK-DH
MKS-1GDV: MK-1GD & MK-DV
MKS-1GDVF: MK-1GD & MK-DVF
Add appropriate power supply
BLACK & WHITE VIDEO ENTRY SECURITY
or
MK-1HD
Two-call video
door station
m P.25
Image view area
Unit dimensions
MK-1GD, MK-1HD
• MK-DH, MK-DV & MK-DVF
205cm
185cm
(2)
(1) 65cm
65cm
MK-2SD
200
210
MK-2SD
60/
83.5
60/
83.5
150cm
140cm
120cm
50cm
50cm
(1) Initial horizontal view
69
215
89
95cm
(2) When the camera is turned up (MK-DH only)
61
Specifications
MK-DV
Power sourse
Consumption
209
173
MK-DVF
98
(1)
27
45
135
5.5
120
130
83.5
98
35
83.5
IER-2
MK-DH
88
Power supply
Calling
Communicarion
29
Video monitor
Scanning lines
Minimum illumination
Door release
Wiring
Distance
DC 18V
MK-1GD : (Max.) 650mA.
MK-1HD : (Max.) 450mA.
MK-2SD : (Max.) 150mA.
PS-1820S, PS-1820UL
Chime, audio & image, approx. 45 sec.
Simultaneous with handsets, approx. 2-1/2 min.
Extend w/MONITOR. All call type voice calling,
common talk.
4 inch direct view flat CRT
525 lines
1 Lux or less at 30cm distance
AC 12V, 0.4A dry-closure contact(L, L).
2 conductors to door.
4 conductors betweens room stations
Door to MK-1GD 200m(1.0mma)
MK-1GD to farthest sub 75m(1.0mma)
MK-1GD to PS18 10m(1.0mma)
20
PanTilt Video Sentry
DOOR
ROOM
2
Features
3 MK-2MCD
Door station
•
•
•
•
Two-PanTilt door, three-monitor system with door release
Instant voice call-in with image
Internal handset communication. All call type voice calling
Transfer of door call-in. Image of a caller stays on
Master station
4
2
2
IER-2
2
Call extension
m P.104
PT
2
BLACK & WHITE VIDEO ENTRY SECURITY
MK-DBC
PS18
Video door station
MK-2MCD
Master station
or
or
MK-DGC
Video door station
MK-DAC
MK-DH
Video door station
Video door station
Fixed camera
Power supply PS-1820S PS-1820UL PS-1820 m P.107
Communication network
Wiring
100m / 1.0mma
75m / 1.0mma
MK-2HCD
MK-DBC
MK-2SD
4-tone
chime
MK-DBC
MK-DGC
MK-2MCD
2
2
PanTilt control
MK-D
MK-DBC
2-tone
chime
H
MK-DGC
MK-2SD
1
2
MK-D
M
NP
A1
A2
MK-DGC
IER-2
MK-2MCD
2
A1
A2
NP
MK-D NP
M
MK-2HCD
Instant voice calling w/image. Pan/tilt camera from any inside monitor station.
All call initiated w/pre-tone/voice. Internal communication on handsets.
Electric door strike
H
MK-2HCD
MK-2HCD
4
4
2
U
DOOR1 SUB
1A1
B1
1A2
B2
NP
CALL
DOOR2 EXT IER-2
1
2A1
S
E
S
2A2
SUB
SUB
IN OUT
IN OUT
B1 B1
B2 B2
NP
DC18V
RLSE. DC18V
+
L
L
DC18V
IN OUT
U
P
IN OUT
+
+
SW1
+
P
P
l MK-2SD may be wired in the same
manner as MK-2HCD.
U : PS-1820S, PS-1820UL
H : AC transformer SW1-ON : Terminated
21
SW1
MK-2SD
MK-2SD
NP
+
ON
OFF
4
B1 B1
B2 B2
4
SUB
B1
B2
DC18V
+
–
SW1
OFF
NP
P
SUB
B1
B2
DC18V
+
–
SW1
ON
• Optional audio door station at second entrance
• Infrared LED's projected on callers at 50cm in the darkness
Lineup
Sub station
4
KC-32EU
Picture memory
unit
m P.25
Sub master
station
4
4
MK-2SD
MK-2SD
Audio sub
station
Audio sub
station
RY-3DL
MKW-R
KAW-D
Surface mount box
for MK-DBC
30kangled box
m P.18
Door release
adaptor
m P.26
MK-DAC, MK-DGC & MK-DBC
220cm
180cm
90cm
65cm
50cm
130cm
45cm 90cm
180cm
Unit dimensions
50cm
MK-DGC
92
210
Power sourse
Consumption
114
12.5 19 37
215
89
69
MK-DBC
MK-DH
130
83.5
130
92
172
Power supply
Calling
Communicarion
63
MK-DAC
44
98
83.5
98
47.5
35
12.5 19 37
RY-3DL
88
29
74
Video monitor
Scanning lines
Minimum illumination
Door release
Wiring
Distance
140
83.5
28
83.5
120
130
IER-2
Max. pan-and-tilt view area:
90cm Vert., 180cm Horiz.
(approx.)
Specifications
170
MK-2SD
200
MK-2MCD, MK-2HCD
98
Electric door
strike
(locally available)
Image view area
Wiring
Electric door strike
Selective door release &
OPTION feature button
MK-2MCD
RY-3DL
2
When the system needs to control
6
two door releases selectively, install
the RY-3DL adaptor.The OPTION
2
button may be used, for example, to
H
turn the porch light, etc. For wiring,
U
6-pin connector is available as an
Electric door strike
accessory. It plugs into the socket
on back of MK-2MCD unit, providing control outputs for Door Release and Option feature.
115
MK-D
in Europe
or
MK-2HCD
Sub master
station
Audio door station
*Not available
BLACK & WHITE VIDEO ENTRY SECURITY
or
MK-2HCD
MK-D*
DC 18V
MK-2MCD: (Max.) 750mA.
MK-2HCD: (Max.) 450mA.
MK-2SD: (Max.) 70mA.
PS-1820S, PS-1820UL
Chime, audio & image, approx. 45 sec.
Simultaneous with handsets, approx. 2-1/2 min.
Extend w/MONITOR. All call type voice calling,
common talk.
4 inch direct view flat CRT
525 lines
1 Lux or less at 30cm distance
AC 12V, 0.4A dry-closure contact(L, L).
2 conductors to door.
4 conductors between inside stations
Door to MK-2MCD 100m(1.0mma)
MK-2MCD to farthest sub 75m(1.0mma)
MK-2MCD to PS18 10m(1.0mma)
42
22
PanTilt Video Sentry
DOOR
ROOM
1
6
*Not available in Europe Scheduled to stop production
MY-CU &
IE-8MD
Door station
Master station
Features
•
•
•
•
•
6 monitors & single PanTilt door
Additional audio door station
Add-on monitors with additional power supply
Answer door from any room station
Selective calling or All Call between room stations
Lineup
Sub station
6
2
IE-8HD
4
Electric door
strike
(locally available)
6-call sub master
MYH-CU
Sub video-monitor
MK-DBC
Video door station
5
PS18
IE-8MD
BLACK & WHITE VIDEO ENTRY SECURITY
IE-8HD
MYH-CU
MY-CU
Main video monitor
2
PS18
6
MYW-BA
Long distance
adaptor
m P.26
4
IF-DA
Door station
IE-8HD
MYH-CU
RY-AC/A
4
6
External signaling
relay
m P.104
IE-8HD
MYH-CU
6
4
Power supply
PS-1820S PS-1820UL
PS-1820 m P.107
IE-8MD & MY-CU
TAR-3
External signaling
relay
m P.105
IE-8HD
MYH-CU
Communication network
Wiring
100m / 1.0mma 75m / 1.0mma
IE-8HD
IE-8HD
IE-8MD
& MY-CU
MK-DBC
MK-DBC
2
2
M
M
M
IF-DA
IF-DA
A1
A2
M
IE-8HD /
MYH-CU
IE-8HD
U
210
IE-8MD & MY-CU
IE-8HD & MYH-CU
110 155
Specifications (MY-CU & IE-8MD)
Power source
Power supply
Communication
Wiring
Distance
83.5
Unit dimensions
79
Electric door strike
6
6
6
4
4
4
4
4
MYH-CU
1
MYH-CU
2
3
4
5
1A1 B1
1A2 B2
U1
U2
1A1 B1
1A2 B2
U1
U2
1A1 B1
1A2 B2
U1
U2
1A1 B1
1A2 B2
U1
U2
1A1 B1
1A2 B2
U1
U2
1A1 B1
1A2 B2
U1
U2
+
–
+
+
+
+
–
+
–
ON
(OFF)
OFF
OFF
OFF
ON
1
2
3
4
1
2
3
4
1
2
3
4
–
D1
D2
E
Electric door strike
IE-8HD
& MYH-CU5
6
5
MY-CU
IE-8HD
4 & 2-tone chime. Pan and tilt camera on any monitor.
Selective call or All call on inside stations.
23
4
6-call master
+
–
D1
E1
D2
E2
EL
EL
SL
SL
1
2
3
4
1
2
–
–
U
1
2
3
4
1
2
3
4
H
l Use a power supply for additional monitors MYH-CUs.
l Run audio/video wires in a separate jacketed cable from door release wires.
U : PS-1820S, PS-1820UL H : AC transformer
18V DC, 1.8A, IE-8MD: 12~18V DC, 0.5A. MY-CU: 18V DC, 0.9A. MYH-CU: 18V DC, 0.4A.
PS-1820S, PS-1820UL
Door calls in w/4 or 2-tone chime, 45 sec. Lift any handset to reply, 2-1/2 min. Press MONITOR to reactivate.
Cut chime tone if needed.
2 parallel wires to door, non-polarized. 6 wires, monitors in loop.
MY-CU to P/T door 50m(0.65mma) 100m(1.0mma), MY-CU to MYH-CU1 35m(0.65mma) 75m(1.0mma)
Master Sentry
DOOR
Features
ROOM
3
8 LEF-C Video
Door station
Scheduled to stop production
*Not available in Europe
Adaptor
•
•
•
•
•
•
Semi-flush residential communication system
One to three PanTilt video doors
Door release activation
All Call and music distribution through stations
Audio door & room sub stations for varied systems
Any combination of doors and rooms up to 11 total stations
Master station
2
Lineup
6
2
5 common
2/door
2
LEF-5C
LE-C
5-call master
m P.67
Sub station
m P.69
MK-DGC
LE-CN
Video door station
Privacy sub
(Photo)
m P.69
PS18
MYW-P3L
PS12
MYH-CUB
3 PanTilt door adaptor
LE-B
Semiflush video-monitor
10-call master
3-call master
m P.67
5 common
2/door
1/station
MK-DBC
LE-BN
Privacy sub
m P.69
6
MYW-P1L
Video door station
Sub station
m P.69
LEF-3C
LEF-1C
1 PanTilt door adaptor
All call sub master
m P.69
MYH-CUB
Electric door
strike
(locally available)
Semiflush video-monitor
LEF-10C
BG-10C
RY-PA
10-call master
MK-DAC
Door release
relay
All call, chime &
music adaptor
m P.69
LE-D
LE-DA
Sub station
m P.69
Sub station
m P.69
Video door station
Power supply PS-1820S PS-1820UL PS-1820 m P.107
PS-1225S PS-1225UL PS-1225 m P.106
Communication network
MK-DGC
Chime tone & LED.
1.
Wiring
MK-DGC
MYH-CUB
&LEF-10C
LEF-10C
MYH-CUB/
LEF-10C
MYW-P3L
(ea.) 2
6
NP
MK-DGC
All call or selective call Varies
A1
A2
1A1
1A2
B1
B2
A1
A2
2A1
2A2
U1
U2
+
–
A1
A2
3A1
3A2
2.
MYH-CUB
&LEF-10C
MK-DGC
Door 1 only w/MYW-P1L (RY-PA req’d for door release)
Doors 1~3 w/MYW-P3L & selective door release. (RY-PA’s req’d for door release)
Unit dimensions
PT
MYH-CUB
20
200
240
200
238
200
110
150
15.5
20 40
U1
U2
+
–
U1
U2
+
–
C
2
3
4
5
6
7
8
9
10
E
R
Y
+
–
1
C
3
4
5
6
7
8
9
10
E
R
Y
+
–
L
K8
K9
K10
L
K8
K9
K10
(*1)
+
–
PS12
(*2)
(*1)Add’l video monitors with another PS-1820 power supply
(*2)Intercom wiring varies by system.
Power source
Power supply
Communication
Wiring
43
RY
B1
B2
Q : RY-PA H : AC transformer U : PS-1820S/UL T : PS-1225S/UL (2.5A)
83.5
230
155
LB
LC
A1
A2
Specifications (LEF-C)
33.5 40
MYW-P3L
RY
DC
DB
DA
E
R
EL2
KC
KB
KA
20
LEF-5C/10C
LA
B1
B2
PS18
3.
RY
23
A1
A2
LEF-10C
Electric door strike
MYH-CUB/
LEF-10C
6
11
PanTilt viewing.
BLACK & WHITE VIDEO ENTRY SECURITY
LEF-10C
Distance
12V DC, 300mA per station.
PS-1225S or PS-1225UL power supply.
Momentary tone & 20 sec. LED. Depress a station button
and press Talk/Listen button. Station LED and occupied
LED remain lit while in use. Single talk channel.
9 common + total No. of stations in system (for
all features except K terminal options)
Between farthest stations 200m(0.65mma)300m(0.8mma)
24
B&W Video Accessories
Dual-call door station
Features
MK-2DA
Two-call video door
station
Wiring
Call two monitors (MK-1GD)
selectively.
Each monitor is powered by a
separate power supply.
l Wide-angle view
l Camera angle adjuster (16k
upward)
l Backlit call buttons
l Acrylic nameplates for
engraving
l While one monitor is in use,
the other monitor is not
operational.
4
2
4
M
2
MK-2DA
1A1
1A2
PT
MK-1GD
A1
A2
L
L
P.
L
L
MK-2DA
+
–
B1
B2
P.
B1
B2
NP
ON
U
+
–
P.
B1
B2
SW1
MK-2SD
+
–
B1
B2
SW1
ON
NP
189
Electric door strike
U : PS-1820S, PS-1820UL H : AC transformer
Specifications
35
119
Power source
Camera
Scanning lines
Minimum illumination
Image view area
Wiring
Wiring distance
MK-2DG
MK-2DG
Two-call video door
station
206
BLACK & WHITE VIDEO ENTRY SECURITY
A1
A2
P.
MK-2SD
U
+
–
MK-1GD
2A1
2A2
Unit dimensions
MK-2SD
MK-1GD
MK-2DA
MK-2DG PANEL
Panel only
120
34
Supplied by monitor in use
CCD camera w/infrared LED’s
525 lines
1 Lux at 50cm from camera
70cm Vert. x 110cm Horiz. at 50cm
2 parallel wires, polarized
Door to monitor 50m(0.65mma)
100m(1.0mma)
Picture memory unit
Features
Wiring
l Easy add-on to present or new
system, color or black & white
l 4 pictures in 1 frame (16 frames),
16, 32 or 60 individual picture
save mode
l Max. 8 pictures stored in memory
Used for
KC-32EU
MK-DV
V
KC-32EU
MK-DV
KC-1MRD, KC-1GRD, KB-3MRD
MK-1GD, MK-2MCD
MK-1GD
2
2
A1
A2
NP
A1
A2
B1
B2
1A1 B1
1A2 B2
V
Unit dimensions
KC-32EU
195
S
S
83.5
V : PS-1820S, PS-1820UL H : AC transformer
KC-32EU
80
54.5
Picture memory unit
Single-gang mounting
Specifications (KC-32EU)
Power source
Power supply
Channel
Wiring
Wiring distance
25
18V DC, 230mA.
24V DC, 160mA.
PS-1820S, PS-1820UL
One video door per unit
2 parallel wires to door (NP).
2 wires to Master (Polarized).
KC-32EU to door 50m(0.65mma)
100m(1.0mma)
KC-32EU to master 25m(0.65mma)
5m(1.0mma) KC-32EU to Power supply
10m(1.0mma) (20m w/1.2mma)
Long distance adaptor
Features
Wiring
l When PanTilt door is more
than 100m to max. 300m
away.
l Separate power supply allows
mounting MYW-BA up to
50m away from master
station or adaptor.
MK-DV
MYW-BA
MK-1GD
A1 B1
A2 B2
A1
A2
+
–
A1
A2
+
–
U
Used for
Cable
Unit dimensions
Specifications
Impedance: 90d. Permitted closed loop DC resistance:
9.9d or less. PE insulation (not PVC).
Power source
Current consumption
Wiring
Distance
MYW-BA
190
Long distance adaptor
PS-1820S/UL of system or separate
250mA. 1mA standby.
2 parallel wires to ea. door & master.
MYW-BA~door 200m(1.0mma)
300m(1.2mma)
MYW-BA~master 50m(1.0 or 1.2mma)
MYW-BA~PS 7m(1.0mma)
10m(1.2mma)
42
80
Selective door release adaptor
Features
Wiring
l Selective door release with one
button
l Door release contacts release
the door where communication
is established.
l Normally open contacts for
electric strike. Normally closed
contacts to work with magnetic
locks.
Electric door strike
Electric door strike
L2
C2
L2
RY-3DL
Door release adaptor
Unit dimensions
V
Specifications
Relay contacts
140
b1
b2
b3
L
D1
E
D2
H
Wiring distance
74
CN12
GR
BL
PL
CN11
OG
YL
GR : Green BL : Blue PL : Purple OG : Orange YL : Yellow
H : AC transformer V : PS-1820S, PS-1820UL
Power source
Power supply
RY-3DL
MK-2MCD
L3
C3
L3
Used for
MK-2MCD, IE-2AD(U), KB-3MRD
JB-2MD, JB-2MED
JF-2MED
RY-3DL
L1
C1
L1
BLACK & WHITE VIDEO ENTRY SECURITY
MYW-BA
MK-1GD, MK-2MCD
MY-CU w/IE-8MD or TD-H/B
MYW-P1L or MYW-P3L w/LEF
LEF-C
TB-ADM10 w/TC-M
42
12~24V DC, 30mA. 12~16V AC, 60mA.
PS-1820S, PS-1820UL; PS-2420S, PS-2420UL;
PS-1225S, PS-1225UL; AC trans.
Normally open output. 1A at 50V AC. 1A at
30V DC (for other types, use matching relay)
Master to RY-3DL 50m(0.65mma)
100m(1.0mma) RY-3DL to Electric door strike
50m(0.65mma) 100m(1.0mma)
Call extension
Features
Unit dimensions
l Announces (chime) call tone only, adjustable
l Indoor mounting
IER-2
Call extension
88
83.5
IE series, MK-1GD, MK-2MCD, KC-1MRD
KC-1GRD, KB-3MRD, NEM-n, NEM-nA, TC-M
JB-2MD, JB-2MED, JA-2MECD, JA-2MCD
JF-1MD, JF-2MED
120
Used for
29
26
Two-Wire Electric Lock Door Phone
DOOR
ROOM
1
1 DA-1AS
Lineup
Boxed set
DA-1AS
DA-1AG
Kit box (silver color)
Kit box (gray color)
Electric door
strike
(locally available)
DAR-1
Call extension
Door station
silver panel
DA-1MD
Master station
DA-1MD
Door station
gray panel
Master station
DAW-P
AUDIO ENTRY SECURITY
*Add an appropriate power supply.
Door station
mounting plate
(83.5mm)
*Add an appropriate power supply.
Power supply
PT-1211D PT-1211C m P.106
Features
Wiring
l Two-wire system including door release
l Door release wired to door station, requiring no power
transformer
l User-optional function button (modification required)
l Call tone MUTE with indicator
l Call extension sounder
310m / 1.0mma
155m / 1.0mma
DA-1MD
DA-1DS
DA-1DG
M
2
DAR-1
2
NP
2
2
P
Communication network
PT-1211D/C
(1)
Electric door strike
DA-1DS,
DA-1DG
DA-1MD
DAR-1
(2)
L
L
~
~
D
E
D
E
PT-1211D/
PT-1211C
S
SE
SW
SW
M
Unit dimensions
DA-1MD
89
22
200
175
100
61
Specifications (DA-1AS, G)
Power source
Power supply
Communication
Wiring
Distance
27
(3)
l Place PT-1211D/C inside electrical enclosure and connect to breaker, less than
16V.
l Do not use PT-1211D/C for any other equipment.
l Terminals SW, SW; Dry-closure contact AC 18V, 40mA to connect user-optional
function (Gate, Light, Garage, Proximity Access Control, etc.)
(1) External device Relay/Controller (2) Door release (AC 16V, 20d or more)
(3) User-optional function (AC18V, 40mA)
Hold down gCALLh button to ring inside station.
DA-1DS,
DA-1DG
S
SE
AC 15V.
PT-1211D, PT-1211C
Press and hold down Button to call.
2 wires, throughout system: PS - Master - Door
- Door rlse.
PT-1211D/C ~ Door rlse. 110m(0.6mma)
200m(0.8mma) 310m(1.0mma)
PT-1211D/C ~ DA-1MD 55m(0.6mma)
100m(0.8mma) 155m(1.0mma)
Chime Tone Intercom
DOOR
ROOM
1
1 C-123L/A
Door station
Master station
Lineup
Electric door
strike
(locally available)
C-D
Door station
C-ML/A
Master station
Boxed set
C-123L/A
Chime-Com boxed set
AUDIO ENTRY SECURITY
Power supply
PS-0602D PS-0602C or Batteries
m P.106
Features
Wiring
l Open voice door answering with door release control
l Adjustable communication volume
l Automatically turns off
l Battery or DC power supply
115m / 0.8mma
C-ML/A
C-D
2
NP
M
Communication network
1
E
+
–
1
E
Electric door strike
W
L
L
H
C-ML/A
C-D
H : AC transformer W : PS-0602D, PS-0602C
M
Specifications (C-123L/A)
Power source
Power supply
Communication
Unit dimensions
C-D
C-ML/A
Wiring
88
83.5
190
120
83.5
Distance
6V DC, 85mA
PS-0602D, PS-0602C or Batteries gCh(SUM-2) x 4 pcs.
Door calls in w/2-tone chime, not adjustable.
Press TALK button to reply, release to listen. Power
automatically shuts off circuit.
2 parallel wires to door, non-polarized
(+ 2 for Electric door strike).
Master to door 75m(0.65mma) 115m(0.8mma)
29
130
44
28
Chime Tone Intercom
DOOR
ROOM
1
1 TCS-MH
Door station
Master station
TC-DC
Door station
Boxed set
TCS-MH
Chime-Phone set
AUDIO ENTRY SECURITY
TC-MH
Master station
Features
Wiring
l Chime-phone intercom set, battery-operated
l Adjustable chime volume
l Battery status indicator
230m / 0.8mma
TC-MH
TC-DC
2
P.
Communication network
1
2
1
2
R
TC-MH
TC-DC
R : Batteries P. Polarized
Specifications (TCS-MH)
Power source
Power supply
Communication
Unit dimensions
28
80
29
83.5
210
130
98
Wiring
Distance
TC-MH
83.5
TC-DC
58
6V DC, 70mA
Batteries gAAh(SUM-3) x 4 pcs
Door calls in w/2-tone chime, adjustable. Pick up to
reply.
2 parallel wires, polarized.
TC-MH to door 150m(0.65mma) 230m(0.8mma)
Chime Tone Intercom
DOOR
ROOM
1 IE-1AD(U)
1
Door station
Master station
Lineup
Electric door
strike
(locally available)
IF-DA
Door station
m P.34
IER-2
Call extension
m P.104
TAR-3
IE-1AD(U)
12~24V DC power supply
12~16V AC transformer
Master station
Features
External signaling
relay
m P.105
Wiring
l Chime tone intercom for 2 locations
l Door release button
l AC or DC power source
360m / 1.0mma
IE-1AD(U)
IF-DA
IER-2
2
NP
2
M
1
2
1
2
Communication network
2
Electric door strike
H
WH
AUDIO ENTRY SECURITY
Power supply
1
E
L
L
+
–
IE-1AD(U)
IF-DA
IER-2
l Run audio wires in a separate jacketed cable from door release wires.
H : AC transformer WH : White(2)
M
Specifications (IE-1AD(U))
Power source
Power supply
Communication
Unit dimensions
IF-DA
130
IE-1AD(U)
98
Door release
Wiring
210
83.5
83.5
Distance
12~16V AC, 180mA.
12~24V DC, 160mA.
AC transformer (for IE & Electric door strike), PS-1225S/UL.
Door calls in w/4-tone chime, adjustable. Pick up
handset to reply.
Contact rating: 24V AC/DC, 500mA
2 parallel wires, non-polarized
(+2 for Electric door strike)
IE-1AD(U) to door 150m(0.65mma) 360m(1.0mma)
28
80
58
30
Chime Tone Intercom
DOOR
ROOM
3 IE-1GD(U)
1
Door station
Master station
Sub station
Lineup
Electric door
strike
(locally available)
IE-JA
Door station
m P.34
IER-2
Call extension
m P.104
AUDIO ENTRY SECURITY
Power supply
IE-1GD(U)
IEH-1CD
Master station
Sub master station
TAR-3
External signaling
relay
m P.105
12~24V DC power supply or
12~16V AC transformer
Features
Wiring
l 3-station chime tone intercom with one door
l Door release button
l All call type room calling
l Chime tone cutout at sub station
l AC or DC power source
360m / 1.0mma
190m / 1.0mma
IE-1GD(U)
IEH-1CD
IEH-1CD
IER-2
IE-JA
2
M
Communication network
1
2
IEH-1CD
2
2
D1
E1
IER-2
IE-JA
IE-1GD(U)
Electric door
strike
M
6
6
H
T
R
C
E
T
R
C
E
T
R
C
E
L
L
L
L
L
L
1
E
+
–
IEH-1CD
l Run audio wires in a separate jacketed cable from door release wires.
H : AC transformer
All Call type calling with pretone & voice
Specifications (IE-1GD(U))
Unit dimensions
Power source
IE-1GD(U)
IEH-1CD
115
IE-JA
116
Communication
210
83.5
83.5
Door release
Wiring
10
100
31
Power supply
61
Distance
12~16V AC, 200mA.
12~24V DC, 200mA.
AC transformer 12~16V, 550mA (for both IE &
Electric door strike), PS-1225S/UL
Door calls in w/4-tone chime to all stations. Chime can
be cut out at sub(s). Pick up any station to reply. Press
CALL to call other inside stations with pretone & voice.
Contact rating: 24V AC/DC, 500mA
2 parallel wires to door, non-polarized.
6 wires in loop, between rooms.
IE-1GD(U) to door 150m(0.65mma) 360m(1.0mma)
Between rooms 75m(0.65mma) 190m(1.0mma)
Chime Tone Intercom
DOOR
ROOM
3 IE-2A2D(U)
2
Door station
Master station
Sub station
Lineup
Electric door
strike
(locally available)
IE-JA
Door station
m P.34
IER-2
Call extension
m P.104
IF-DA
Door station
m P.34
IE-2AD(U)
IEH-1CD
Master station, 2 door
releases
Master station
Sub master station
TAR-3
IEH-1C2D
External signaling
relay
m P.105
12~24V DC power supply
12~16V AC transformer
2 door release
Features
Wiring
l 3-station chime tone intercom
l 2 door stations w/door release
l All call type room calling
l Chime tone cutout at sub station
l Door selective monitoring at master station
l AC or DC power source
360m / 1.0mma
190m / 1.0mma
IE-2A2D(U)
IE-JA
2
M
IEH-1C2D
8
IER-2
2
2
M2
1
2
IER-2
IE-JA
8
IEH-1C2D
2 IF-DA
1
2
Communication network
IEH-1C2D
Electric door strike 1
IE-2A2D(U)
Electric door strike 2 H
D1
E1
D2
E2
T
R
C
E
T
R
C
E
T
R
C
E
L
L
L
L
L
L
BL
BL
+
–
BL
AUDIO ENTRY SECURITY
Power supply
IE-2A2D(U)
1
E
IF-DA
BL : Blue(2)
IEH-1C2D
( 1)
All call type voice calling between rooms
(*1) Available in IE-2A2D(U) or IE-2AD(U) w/RY-3DL
Specifications (IE-2A2D(U))
Power source
Unit dimensions
Power supply
IE-JA
115
IE-2A2D(U), IE-2AD(U)
Communication
83.5
10
210
83.5
83.5
210
116
IEH-1CD
130
IF-DA
98
H : AC transformer
83.5
28
Door release
Wiring
100
68
100
61
Distance
12~16V AC, 200mA.
12~24V DC, 200mA.
AC transformer 12~16V AC, 550mA (for both IE &
Electric door strike). PS-1225S/UL
Door calls in w/4- or 2-tone chime to all stations, 45
sec. Chime can be cut out at sub. Pick up any station
handset to reply. Press CALL to call other stations with
pretone & voice.
Contact rating: 24V AC/DC, 500mA
2 parallel wires, non-polarized.
6 wires in loop, rooms.
IE-2A2D(U) to door 150m(0.65mma) 360m(1.0mma)
Between rooms 75m(0.65mma) 190m(1.0mma)
32
Chime Tone Intercom
DOOR
ROOM
2
6 IE-8MD
Door station
Master station
Lineup
Sub station
Electric door
strike
(locally available)
IE-JA
Door station
m P.34
TAR-3
External signaling
relay
m P.105
IF-DA
Door station
m P.34
AUDIO ENTRY SECURITY
Power supply
PS-1225S PS-1225UL
PS-1820S PS-1820UL
IE-8MD
IE-8HD
6-call master
6-call sub master
RY-AC/A
External signaling
relay
m P.104
PS-1225 m P.106
PS-1820 m P.107
Features
Wiring
l Expandable to 6-station system
l Selective or All Call between inside stations
l Door select and monitor button (on IE-8MD only)
l AC or DC power source
l Selective door release control
l Chime tone cutout on inside stations, selectable
360m / 1.0mma
IF-DA
M
IE-8MD IE-8HD IE-8HD IE-8HD IE-8HD IE-8HD
2
IE-8HD
IE-8MD
1
M
1
2
IE-8HD
2
4
IE-JA 2
Communication network
IF-DA
190m / 1.0mma
1
2
3
M
Electric door strike
IE-JA
Electric door strike H
M
4
IE-8HD
5
IE-8HD
T
6
IE-8HD
4
4
4
4
1
D1
E1
D2
E2
EL
EL
SL
SL
1
2
3
4
+
–
2
1
2
3
4
station # setting
2
4 5 6
3
1
2
3
4
4
1
2
3
4
5
1
2
3
4
6
1
2
3
4
3
4
5
6
4 5 6
4 5 6
4 5 6
4 5 6
H : AC transformer T : PS-1225S/UL U : PS-1820S/UL or AC transformer
Internal communication by Selective Call or All Call. Chime tone can be muted at
each station selectively.
Specifications (IE-8MD)
Power source
Unit dimensions
IF-DA
Power supply
130
IE-8MD
IE-8HD
210
83.5
83.5
98
Communication
28
IE-JA
115
110
116
33
83.5
10
79
Door release
Wiring
Distance
12~16V AC, 900mA.
12~18V DC, 500mA
Intercom only; DC 12V or 18V power supply.
AC transformer 12V AC, 10VA or 16V AC, 14VA w/no
load voltage 20V or less.
Intercom + Electric door strike; 12V AC, 10VA only
Door calls in w/4- or 2-tone chime and LED, 45 sec.
Pick up any handset to reply. Press 1 ~ 6 to call other
station with pretone and voice or All Call. Single
channel, common talk system.
Contact rating: 24V AC/DC, 350mA.
2 parallel wires, to door.
4 wires in loop, between rooms.
IE-8MD to door 150m(0.65mma) 360m(1.0mma)
Rooms 75m(0.65mma) 190m(1.0mma)
Audio Door Stations
IE/IF Series
Unit dimensions
98
AX-DM
135
IE-DC
130
IF-DA
83.5
28
100
IE-DC
IF-DA
83.5
IE-JA
34
43
IE-FY
220
83.5
128
115
116
10
160
AX-DM
Specifications
Audio door station
Mullion type
Wiring
Wiring distance
Features
Used for
l Weather resistant audio door
stations
l Hands-free communication
l Call button rings chime or tone at
inside station
IE-1AD(U), IE-1GD(U),
IE-2AD(U), IE-8MD,
TD-nH/B w/DE-UR
(n=3, 6, 12 & 24)
TC-M w/TB-AD1
TC-M w/TB-AD10
AX
Some applications
l At multiple doors
w/TB-ADM10 in place of
video door
AUDIO ENTRY SECURITY
IE-FY
Door station
66
2 parallel wires to master, non-polarized
150m(0.65mma) 230m(0.8mma)
360m(1.0mma)
Flush mount station
Door station
22.5
Door station
Door station
IE-JA
160
Surface mount station
IE-DL Series
Unit dimensions
Surface mount station
175
IE-DL1, IE-DL2, IE-DL3
IE-DL1
83.5
1-call surface-mount door
station
120
25.5
Specifications
IE-DL2
2-call surface-mount door
station
Power source
Communication
Wiring
Wiring distance
IE-DL3
3-call surface-mount door
station
12~16V AC, 140mA or 12~24V DC, 140mA.
Press CALL to ring a flat station. Talk hands-free after
the inside station replies.
4 to 8 wires, polarized.
150m(0.65mma) 230m(0.8mma)
360m(1.0mma)
Features
Used for
l 1~3-call surface-mount door
station with aluminum panel.
l Directory back illumination.
l AC/DC power source.
IE-1AD(U), IE-1GD(U),
IE-2AD(U), IE-2A2D(U),
IE-8MD, TD-nH/B w/DE-UR
(n=3, 6, 12 & 24)
34
Hands-free Color Video BUS Apartment System
The GH system is Hands-free Color video apartment system employing 1pair for Audio & 1pair for video connections.
The resident can easily identify visitors by crisp "Color image" together with convenient "Hands-free communication."
The GH system configures basically two systems: Standard 48-station, Expanded 500-station systems. Apartment
station is selectable out of three types: Color monitor hands-free station (w/optional handset), B&W monitor hands-free
station, and hands-free audio station. Entrance station is of a fully modular design with vandal-resistant zinc die-cast
panel. The GH system is totally flexible, allowing you to mix-and-match components to create the exact system
configuration and features needed for each application.
Capacity
Standard
Expanded
48 500
Apartment station
MULTI-UNIT ENTRY SECURITY
• Identify visitors by crisp "COLOR" image
• Convenient "Hands-free communication"
• Up to 4 apartment stations can be linked
per Residence (max. 2 monitor stations)
• Monitoring an Entrance camera
from Apartment monitor station
• Add an external signaling device to Apartment station
• Call tone off at individual station with LED indicator
• Doorbell at individual door
• Auto-Entry (Doctor call)
• User-optional feature using SERVICE button,
such as turning on/off light, elevator control, etc.
• Panic call transfer to security guard station
Color monitor hands-free station
B&W monitor
hands-free station
Audio
hands-free station
Color monitor
hands-free station
with optional handset
* The design and specifications are subject to change without notice for improvement.
35
Apartment Station
Simple and easy installation
• Two single-pair BUS for audio & video
• Easily links Entrance station to
Apartment station
• Resident names & room numbers etc.
are programmable by PC
Entrance station
Security guard station
Capacity
Capacity
Expanded
5 16
Entrance station
• Vandal-resistant zinc die-cast panel
• Sleek & compact semi-flush design
• Digital name scrollings
- Search resident names and room numbers
using keypad
- Customer programmable welcome messages
- Names & welcome messages are selectable
from 5 different languages
(English, French, Spanish, German & Dutch)
Standard
Expanded
2
4
Security guard
station
• Communicate with all residents and Entrance stations
• Receive all Entrance station call-in
(Reception mode function)
• Absence call-in memory stored with Callback
• Receive panic calls from Apartment stations
MULTI-UNIT ENTRY SECURITY
Standard
36
Hands-free Color Video Bus Apartment System
System Configuration
Standard system
Divided cabling
with GH-4Z
Trunk line No.1
5 Entrance stations
2 Security guard stations
48 Residential stations
Monitor to monitor
cabling
Trunk line No.6
1Px2
1Px2
On the same trunk line, do not
have two wiring methods mixed,
Divided cabling with GH-4Z &
Monitor to monitor cabling
1Px2
1Px2
1Px2
GH-4Z
1Px2
1Px2
GH-1KD
GH-1KD
GH-1MD
1Px2
GH-1KD
GH-1KD
1Px2
1Px2
1Px2
1Px2
GH-4Z
1Px2
GH-1KD
GH-1KD
GH-1MD
1Px2
GH-1KD
1Px2
1Px2
GH-1KD
1Px2
1Px2
1P
1Px2
1Px2
1P
GH-4Z
MULTI-UNIT ENTRY SECURITY
Doorbell
GH-1KD
Doorbell
GH-1MD
1Px2
GH-1KD
+
GH-HS
GH-1AD
Apartment
No.2~5
300m / 0.8mma
1Px2
150m / 0.8mma
1Px2
1Px2
PS24
1P
1P
GH-BC
PS24
1P
Entrance Station : Max. 5
Wiring distance: Entrance station - Bus & Video control unit 300m
Video control unit - Farthest Video Apartment station 150m
(Expandable with additional Video control unit)
Bus control unit - Farthest Audio Apartment station 300m
Accumulated total Audio wiring distance 2,500m
37
GH-1KD
GH-1KD
GH-1AD
GH-VBC
PS24
1P
1P
PS24
1P
1P
GH-MK
GH-MK
Security Guard Station : Max. 2
Expanded system
16 Entrance stations, 2 common trunk lines (8 each per common line)
4 Security guard stations, 2 common trunk lines (2 each per common line)
500 Residential stations, 4 sub trunk lines (125 each per sub trunk line)
Trunk line
No.1
No.6
No.1
Apartment
station
Max.125
/SUB line
No.6
Apartment
station
Max. 125
/SUB line
1Px2
No.2~5
1Px2
GH-BC
PS24
1Px2
1Px2
1Px2
1Px2
GH-VBC
PS24
1Px2
No.2~5
GH-BC
PS24
1Px2
GH-VBC
PS24
SUB COMMON 2 & 3
300m / 0.8mma
1Px2
1Px2
SUB COMMON 1
SUB COMMON 4
1Px2
1P
1Px2
1P
1P
1P
1P
GH-BCX
PS24
GH-BC
PS24
1Px2
1P
GH-VBX
1P
GH-BC
PS24
COMMON 2
1P
1P
PS24
1P
1P
GH-MK
GH-MK
Security Guard Station
Max. 2/COMMON line
Entrance Station
Max. 8/COMMON line
COMMON 2
1Px2
1P
PS24
PS24
150m / 0.8mma
1P
1P
PS24
Entrance Station
Max. 8/COMMON line
1P
1P
MULTI-UNIT ENTRY SECURITY
COMMON 1
COMMON 1
GH-MK
GH-MK
Security Guard Station
Max. 2/COMMON line
Wiring distance: Entrance station - Expanded Bus & Expanded Video control unit 300m
Expanded Video control unit - Farthest Video Apartment station 150m
(Expandable with additional Video control unit)
Expanded Bus control unit - Farthest Audio Apartment station 300m
Accumulated total Audio wiring distance 2,500m/SUB line
38
Hands-free Color Video Bus Apartment System
Entrance station
Direct-select call button
Digital name scrolling
The directory button panels back-lit
display illuminates resident's name
or unit number
Color camera
VFD Display
Directory scroll/
Cancel/ Call buttons
Zinc die-cast panel
Keypad illumination
Audio module
Access control/
room number
dialing keypad
In-use LED
Call button
Directory card &
cover
Audio Module
GH-DP
Audio panel
Digtal name scrolling module
GH-DA
Audio module
GF-NSP
GH-NS
Display module panel
Digital name scroll
display module
Front frame & back box
Camera Module
MULTI-UNIT ENTRY SECURITY
GF-2F
2-module front frame
GF-VP
GH-VA
GF-10KP
Camera panel
Camera module
GH-10K
10-key module panel
10-key module
GF-3F
3-module front frame
Call switch Module
GF-1P
GF-2P
1-call panel
2-call panel
GF-2B
2-module back box
GF-3P
3-call panel
GF-4P
GH-SW
4-call panel
Call switch module
GF-AP
GH-AD
GF-BP
Address panel
Address module
Blank panel
Option
39
GF-3B
3-module back box
Specifications (GH-DA,GH-VA)
System layout example
Wiring
Type of cable
Direct-select call button
1P
l Searches of resident names and room
number using the keypad
l Customer programmable welcome
messages can also be shown in 5
different languages
(English, French, German, Spanish
& Dutch )
l White LED illuminator truns on in low-light
conditions
1P
#2
1P
#1
1P
Mounting
H
GH-BC
M
Housing
N
H
Specifications (GH-SW,GH-10K,GH-AD)
M
Lighting
Housing
GH-VBC
N
Digital name scrolling
1P
1P
1P
#1
1P
Yellow LED
Fire-retardant plastic
Specifications (GH-NS)
1P
#2
Two single-pair cable common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
dia.
Box and front frame GF-2B,3B
and GF-2F,3F
Fire-retardant plastic
Power source
1P
1P
1P
Housing
N
DC 24V, supplied by
PS-2410LD, LC
Fire-retardant plastic
GH-BC
N
GH-VBC
N
Unit dimensions
GH-DA
GF-VP
95.2
93
7.9
GH-VA
95.2
GH-DP
110
93
49.5
108
15.8
4.5 38
105.6
GH-NS
9.9
28.9
38
9
GF-2B
295
16
16
4.5 38
106.2
GF-3B
200
320
225
GF-3F
135
14.4
110
106.2
GF-2F
GH-10K
95.2
95.2
14.4
110
110
44
135
42
85
GF-202HB
110
44
243
GF-202H
243
22
4-call
290
290
65
Audio/Video + Name scroll
225
AIPHONE
320
Hooded surface-mount box
GF-10KP
100.3
GF-NSP
88.3
110
GF-nHB
52.3
MULTI-UNIT ENTRY SECURITY
Rain hood
108
110
88.3
GF-nH
7.9
51
GH-SW
95.2
GF-4P
AIPHONE
270
135
16
16
44
44
40
Hands-free Color Video Bus Apartment System
Entrance station components
Number of calling button
4.
8.
12.
AIPHONE
AIPHONE
16.
AIPHON E
20.
AIPHON E
24.
25.~48.
AIPHONE
AIPHONE
GH-NS, GF-10K
AIPHON E
AIPHON E
(1)
(2)
(3)
(4)
(5)
(6)
(7)
GH-VA
GF-VP
GH-DA
GH-DP
GH-SW
GF-4P
GF-2F
GF-2B
GF-3F
GF-3B
GF-BP
GH-AD
GF-AP
GH-NS
GF-NSP
GH-10K
GF-10KP
1
1
1
1
1
1
1
1
-
1
1
1
1
2
2
2
2
-
1
1
1
1
3
3
2
2
-
1
1
1
1
4
4
2
2
-
1
1
1
1
5
5
3
3
1
1
1
1
1
6
6
3
3
1
-
-
1
-
1
-
-
-
-
-
-
-
-
1
1
1
1
1
1
1
1
2
2
-
For more than
7 GH-SW, install
additional power
supply & special
device required.
Contact local
AIPHONE distributor
(1) Camera (2) Audio (3) Call switch (4) 2-module Front frame (5) 3-module Front frame (6) Option (7) Digital name scroll
Interconnecting Modules with Plug-in Conectors
Mounting
. GF-nH
W
GF-3B
. GF-nHB
42
W
85
GH-DA
GH-DP
GF-3F
(4)
H
H
CN3
(3)
GH-SW
GF-4P
(5)
(2)
(1)
CN1
65
22
H
W
GF-102H/HB
243
155
GF-202H/HB
243
290
GF-103H/HB
338
155
GF-203H/HB
338
290
GF-303H/HB
338
425
CN1
CN2
CN2
CN1
CN1
CN2
CN2
CN1
MULTI-UNIT ENTRY SECURITY
(1) Tamper-proof screw & screwdriver (supplied with GH-BC) (2) Module-mounting bracket (supplied with
GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box
1.
GH-VA
2.
(1)
(1)
3.
200
mm
295
mm
25mm
44mm
W
(2)
25mm 25mm
W
44mm
(2)
1. Two 2-module back boxes
2. Three 3-module back boxes
(1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
GF-2B/3B
x1
x2
x3
x4
x5
x6
x7
x8
x9
W
110
245
380
515
650
785
920
1055
1190
GH-NS
CN3
CN1
CN3
CN1
CN2
GH-DA
GH-10K
3. Back box total width (mm)
Adjust camera angle
• Viewing from initial
camera position
• Changing camera angle
• Image view area
GH-VA
95cm
Camera
center
GH-VA
50cm
65cm
113cm
24cm
GH-VA
GH-VA
65cm
1. Open the rubber cap.
2. Change the camera angle with the lever
113cm
24cm
*Do not forget to replace the cap.
50cm
41
When adjusted
to the left
When adjusted
to the right
Residential station
Features
GH-1KD
GH-1KDS
(white)
(silver)
Color monitor apartment station
• Selectable 3 types of stations (Color monitor, B&W monitor, or Audio only)
• Hands-free communication, auto-voice actuation
• Press-talk operation available
• Max. 4 apartment stations can be linked per Residence (max. 2 monitor stations)
• Monitoring a Video entrance station (audio & video)
• Call tone cutout with LED indicator
• Security guard call
• Additional handset available for GH-1KD
• Option
External signaling device to Apartment station (w/GH-RY)
Doorbell at individual door with different call tone
Auto-Entry (Doctor call), door strikes automatically opens by pressing the Call button at the
entrance station. (Not available to use together with entrance light feature)
-Panic call, call an Emergency to the Security guard station(s) by panic call button
User-optional device can be controlled with SERVICE button, such as
-Light on and off at entry way to elevator
-Elevator control, goes down to the ground floor or up to resident floor
Not available GH-1MD
Functions
Specifications (GH-1KD, GH-1MD, GH-1AD)
Buzzer
Apartment station
Power source
DC 24V, supplied from
Bus control units,
GH-BC & GH-VBC
Video monitor
GH-1KD: 3-1/2 inch
color LCD
GH-1MD: 4 inch B&W CRT
Wiring
GH-1KD, GH-1MD:
Two Single –pair cables
common
GH-1AD:
Single-pair cable common
Mounting
Wall-mounting only
Housing
Fire-retardant plastic
External signaling
Panic alarm
Cal
ling
&C
Do
or r
om
ele
mu
Mo
nic
nito ase
atio
rin
n
g (a
udi
o/
vid
eo)
B&W monitor apartment station
ory
em
n
larm
g m atio
ic a callin unic
Pan
ce
mm
Co
sen
Ab ng &
li
Cal
GH-1MD
O
PANIC CALL switch
Doorbell
Door release
Monitoring (audio)
Reception mode function
Entrance station
Security guard station
Trunk line
Unit dimensions
Audio apartment station
Monitor to
monitor cabling
Divided cabling with GH-4Z
175
GH-1KD
GH-1AD
1Px2
1Px2
1Px2
125
32
GH-1MD
210
1Px2
GH-1KD
GH-1KD
MULTI-UNIT ENTRY SECURITY
Calling & Communication
GH-1KD
1Px2
GH-4Z
160
55.5
GH-1AD
Only available to connect
on a trunk line with
GH-4Z used
GH-HS
Option handset for GH-1KD
175
1Px2
GH-1AD
GH-1KD
1Px2
125
32
GH-HS
On the same trunk line do not
have two wiring methods mixed,
Divided cabling with GH-4Z &
Monitor to monitor cabling
140
GH-1MD
1Px2
177
1Px2
45
46
42
Hands-free Color Video Bus Apartment System
Security guard station
Features
Unit dimensions
GH-MK
Security guard station
GFW-S
Desk-top stand
60
83.5
210
l Call to residential station
GH-MK
l Digital display shows name of resident &
room number
l Monitoring a Video entrance station (audio)
l Receive all Entrance station call-ins
(Reception mode function)
215
69
l Absence call-in memory stored with Callback
l Option
Specifications (GH-MK)
Doorbell at door with different call tone
User-optional device can be controlled with Power source DC 24V, supplied by
PS-2410LD, PS-2410LC
SERVICE button, such as
Max. 16 letters for names; English,
VFD display
-light on and off at entry way to elevator
French, German, Spanish & Dutch
l Receive a Panic call from apartment station
Wiring
Type of cable
2 single-pair cables
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm dia.
Mounting
Wall-mounting or Desk-top
mounting on GFW-S
Fire-retardant plastic
Housing
Control units
System layout example
1P(Audio)
1P(Video)
BUS (Audio/Video) MAX.6
Monitor to monitor
cabling
Divided cabling with GH-4Z
1
2
3
4
5
6
150m
Expand pos.
1Px2 1Px2
GH-4Z
GH-1KD
GH-1KD
GH-1KD
EXP
GH-1KD
GH-VBC
GH-1KD
MULTI-UNIT ENTRY SECURITY
GH-BC
Bus control unit
STD
max. 2
On a single trunk line, do not have
two wiring methods mixed,
Monitor to monitor & Divided cabling
with GH-4Z
GH-BC
GH-VBC
PS24
PS24
150m
GH-1KD
PS24
GH-BC GH-VBC
PS24
1Px3
PS24
PS24
EXP
STD
Standard pos.
Wiring distance
GH-VBC
Video Bus control unit,
expander video control
GH-BC, GH-VBC to Farthest Entrance station
GH-BC, GH-VBC to Farthest Video apartment station
GH-BC, GH-VBC to Farthest Audio apartment station
GH-BC, GH-VBC to each Power supply
GH-RY to Entrance station
Accumulated Audio lines (R1, R2) Total wiring distance
Distance (Diameter of wires)
300m(0.8mm)
150m(0.8mm) Expandable 150m
with additional GH-VBC & Power supply
300m(0.8mm)
5m(0.8mm)
300m(0.8mm)
2,500m(0.8mm)
Type of Cable
2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia.
Specifications (GH-BC, GH-VBC)
Unit dimensions
Power source
GH-4Z
Consumption
Wiring
Housing
108.5
Video 4-zone divder
GH-BC,
GH-VBC,
GH-4Z
122.5
43
DC 24V, supplied by
PS-2410LD, PS-2410DIN
900mA.
Single-pair cable common
Fire-retardant plastic
Specifications (GH-4Z)
61
Wiring
Mounting
Housing
Two Single-pair cables common
DIN rail
Fire-retardant plastic
Expanded control units
Features
Available 2nd Quarter 2006
l Expandable to max. 500 Apartment stations, 16 Entrance stations, and 4 Security guard stations
System layout example
GH-1KD
GH-BCX
Expanded Bus control unit
GH-BC
GH-VBC
PS24
PS24
GH-1KD
GH-BC
SUB2 SUB3
1Px2
SUB1
PS24
1Px2
GH-VBC
PS24
SUB4
1Px2 COMMON 1
COMMON 1
PS24
PS24
GH-BCX
GH-VBX
PS24
PS24
1Px2 COMMON 2
PS24
GH-MK
COMMON 2
GH-MK
GH-MK
GH-MK
PS24
GH-BC
GH-BC
PS24
PS24
l COMMON trunk line: Requires one each of GH-BC & Power supply
l COMMON trunk line: Max. 8 Entrance stations & 2 Security guard stations
l SUB COMMON trunk line: Max. 125 Apartment stations
GH-VBX
Expanded video control unit
Specifications (GH-BCX, GH-VBX)
Unit dimensions
GH-BCX, GH-VBX
Power source
GH-BCX: DC 24V, supplied by PS-2410LD,
108
PS-2410LC. GH-VBX: Supplied from GH-BCX
61
210
Wiring
Single-pair cable common
Mounting
DIN rail
Housing
Fire-retardant plastic
Power supply
Specifications
PS-2410LD
PS-2410LC
164
RD
BK
RD : Red, BK : Black
PS-2410LD
PS-2410LD PS-2410LC
Power source
AC220-240V AC120V
Secondary output voltage & current
DC24V, 1A DC24V, 1A
66
95
Power supply
PS-2410LC
MULTI-UNIT ENTRY SECURITY
Unit dimensions
Option
GH-RY
External signaling relay
entrance light, external buzzer
W-DIN11
DIN mounting rail
for GH-BC, GH-VBC, GH-4Z
44
Hands-free Color Video Bus Apartment System
Preliminary Information
Available mid. 2007
GH Lift control adaptor
Features
l Lift is controllable from apartment station while communicating with
entrance station.
When door release button is pressed, electric door strike is activated and
simultaneously output signal is transmitted to the lift controller or the access
controller.
l Selectable dry contact: Normally Open or Normally Closed
l System set up data is programmable on your PC
* GH-BCX/A & GH-DA/A is required to use GHW-LC.
GHW-LC
Lift control adaptor
Functions
Cabling
1P(Audio)
1P(Video)
1P
GH-1KD
1P×2
un
eas
e
mm
rel
Co
or
Do
Distribution
point
PS24
PS24
)
Ca
on
cti
g&
ea
llin
GH-VBC
(on
1P×2
GH-BCX/A
SUB1
GH-VBX
Entrance station
Lift
PS24
COMMON 1
Unit dimensions
GH-BC
GH-BC
GHW-LC
Distribution
point
PS24
Distribution
point
PS24
108
MULTI-UNIT ENTRY SECURITY
GH-BC
ol
ntr
Co
ica
tio
n
GH-1KD
210
61
1P×2
PS24
GHW-LC
Specifications
Power source
Relay
Wiring
Mounting
Housing
Supplied by GH-BC
Output
20
Contact rating 24V AC/DC, 0.5A
N/O or N/C dry contact
Operating time From 1 to 600 second
Single-pair cable
DIN rail
Fire-retardant plastic
GH-MK
PS24
Entrance station
Lift
PS24 :PS-2410LD,
45
PS-2410LC
Lift controller
*Not available in Europe
GH CCTV camera interface adaptor for Reception
Features
Tenant can receive a call from concierge with visitor’s picture image through
CCTV camera.
In luxurious condominium, concierge receives all visitors directly instead of
using the entrance station. In case concierge asks the tenant to verify the
visitors, GH-CCTV allows GH-MK to call apartment station with the image from
CCTV transferred. The tenant can communicate with concierge while the
picture of visitor displayed at the apartment station.
Monitoring the CCTV camera is also available from the apartment station.
GH-CCTV
CCTV camera interface
adaptor for Reception
Functions
Cabling
1P(Audio)
1P(Video)
1P
CCTV camera
Video
CCTV camera
Monitoring (Video)
Coaxial cable
GH-1KD
Power
supply
GH-1KD
GH-CCTV
tio
a
nic
Monitoring only
u
m
om
1P×2
C
1P×2
GH-BC
GH-VBC
GH-MK
PS24
PS24
CCTV camera
Coaxial cable
Unit dimensions
Power
supply
GH-CCTV
GH-CCTV
205
340
Mounting
1P×2
93
Specifications
Power source
Video signal
1P×2
MULTI-UNIT ENTRY SECURITY
n
g
llin
Ca
GH-MK
Supplied by GH-BC & GH-VBC
NTSC 1V P-P
75d
Desk-top or wall-mounting
PS24
Parking lot
PS24 :PS-2410LD,
PS-2410LC
46
Hands-free Color Video Bus Apartment System
Cabling
1P(Audio)
1P(Video)
1P
Standard system
Capacity
5 Entrance stations
2 Security guard stations
48 Residential stations
Monitor to monitor cabling
Divided cabling with GH-4Z
Trunk line No.2
1Px2
Trunk line No.1
1Px2
Doorbell
1Px2
GH-4Z
1Px2
GH-1KD
1Px2
1Px2
1Px2
1Px2
1Px2
1P
1P
1Px2
GH-4Z
Doorbell
Doorbell
Doorbell
Doorbell
GH-1KD
GH-1KD
GH-1KD
GH-1MD
GH-1MD, unlike GH-1KD,
is only available to connect
on a trunk line
with GH-4Z used
1Px2
GH-1AD
GH-1AD
GH-1KD
Max. 4 apartment stations can be linked per Residence
(including max. 2 monitor stations)
1Px2
On the same trunk line, do not have two wiring methods mixed,
Monitor to monitor & Divided cabling with GH-4Z
1Px2
MULTI-UNIT ENTRY SECURITY
Trunk line
No. 3 to 6
1Px2
Distribution
point
R1
PS24
R2
PS24
GH-BC
GH-VBC
1Px2
Light control
Timer
Entrance
No. 2 to 5
GH-RY
1Px2
1P
1P
AC
1P
Light
PS24
Door release
Doorbell
PS24
GH-MK
Entrance station
Security guard station
Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation
47
Wiring
Monitor to monitor cabling
Divided cabling with GH-4Z
Trunk line No.2
Trunk line No.1
GH-4Z
A
B
R1 R2 B1 B2
GH-1KD
OUT
B1
B2
R1 R2 B1 B2
LINE OUT
B1
B2
OUT 3
OUT 4
R1
R2
1Px2
B1
IN
B2
OUT
IN
R1
R2
R1
R2
C
CE
A
B
Terminate
the last GH-4Z
1Px2
B1
B2
R1
R2
A
IN
IN
B1
B2
OUT 1
R1
R2
B1
B2
OUT 2
R1
R2
LINE IN
R1 R2 B1 B2
R1
R2
C
CE
GH-1MD
R1
OUT
R2
R1
OUT
R2
R1
IN
R2
C
CE
R1
IN
R2
C
CE
GH-1AD
GH-1AD
Doorbell
1Px2
R1
OUT
R2
R1
IN
R2
C
CE
A
B1
OUT
B2
1Px2
B1
B2
R1
OUT
R2
B1
IN
B2
B
1Px2
B1
IN
B2
B1
OUT
B2
1Px2
GH-4Z
Doorbell
B1
OUT
B2
Doorbell
Door
bell
1Px2
B
R1
IN
R2
C
CE
A
B
GH-1KD
B1
OUT
B2
GH-1KD
B1
IN
B2
B1
IN
B2
R1
OUT
R2
R1
OUT
R2
R1
IN
R2
C
CE
R1
IN
R2
C
CE
A
Door
bell
B
A
B
GH-1KD
GH-1KD
1Px2
Trunk line
No. 3 to 6
GH-BC
R1
R2
+
-
+
-
+
-
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
Power supply
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6
IN1
AC
IN2
IN3
IN4
AC
Power supply
IN5
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
+
-
EXP
MULTI-UNIT ENTRY SECURITY
Distribution
point
1Px2
STD
Video Entrance station No. 2 to 5
Light control
Timer Orange
Blue
1Px2
GH-MK
1P
Orange GH-RY White
Light
GH-DA
Doorbell
CN2
R1 R2 ELB ELC ELM RY RY
CN1
A1 A2
CN3
+
GH-VA
GH-NS
CN1
+
CN3
-
AC
+
-
AC
-
CN100
R1
R2
R1
R2
R1
R2
C
CE
+
-
R1
R2
C
CE
+
-
Power supply
Power supply
GH-10K
2nd
GH-MK
SW1
SW1
Entrance station
Apartment station and Security guard station have following options
GH-1KD, GH-1MD, GH-1AD
l Doorbell
l Panic alarm switch
l User-optional device*(not available with GH-1MD)
l External buzzer*
l Doctor call*
Doorbell button
*Option connector cable is required.
Contact local AIPHONE distributor
locally available
R1
R2
C
CE
K
KE
••
••
••
Option connector cable
User-option device
External buzzer
Doctor call
GH-MK
l Doorbell
l User-optional device*
l External buzzer*
R1
R2
C
CE
••
••
••
Option connector cable
User-option device
External buzzer
Doorbell button
Panic Call switch
(w/break contact)
locally available
*Option connector cable is required.
Contact local AIPHONE distributor
48
Two-Wire Bus System
ENTRANCE
5
RESIDENCE
100or250 GF Audio
Entrance station
Entrance station modules
l Direct-select Call Button
l Digital Name Scrolling
l Audio Module
l Direct-Select Keys
GF-DP
GF-1P
GF-2P
Audio panel
m P.55
1-call panel
m P.55
2-call panel
m P.55
GF-DA
GF-3P
GF-4P
Audio module
m P.55
3-call panel
m P.55
4-call panel
m P.55
Audio, Digital keypad, LCD Directory
& address panels
Audio, 4-call
Audio, 16-call with address panel
Frame & Box
Assemble the following in as many rows as required.
GF-2F 2-module Front frame
GF-2B 2-module Back box
GF-3F 3-module Front frame
GF-3B 3-module Back box
GF-SW
Call switch module
m P.55
PP.56
Features
Communication network
MULTI-UNIT ENTRY SECURITY
l Fully modular Entrance station. Vandal-resistant construction
l Two-wire Bus throughout system
l One or two apartment stations
l Call tone off at individual station with blinking LED indicator
l Door release & external light, Bus line-controlled
l User options: Doorbell at individual door. Auto-Entry (auto door
strike)
l User-optional feature using SERVICE button
GF-1DK GF-1DK
GF-1DK
Capacity
l 1 or 2 apartment stations within a residence
l Entrance station panel : 100-call sized
l Direct-select call button : Total 150 apartment stations incl. second stations
l Digital name scrolling : Total 250 apartment stations incl. second stations
GF-1DK
O
1.
GF-MK
1
A
2
B
C
D
3
E
G
4
H
5
I
J
K
L
M
PQ
8
R
T
U
F
6
N
7S
O
9Z
WX
V
Y
0
1.
M
GF-MK
2.
1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
V
O
9Z
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
2.
5.
J Calling & Communication K PANIC CALL sounding & Answer-back.
GF-MK; Concierge station must be used w/GF-1DK.
I Doorbell O PANIC CALL switch used for GF-1DK only
Bus line-controlled; M Door Release L External light
49
l Digital Name Scrolling
Apartment station
Concierge station
Bus control unit
Lineup
GF-NSP
LCD directory panel
m P.55
GF-BC
GF-nH
GF-nHB
Rain hood
m P.56
Hooded surfacemount box
m P.56
GF-AP
GF-AD
Address panel
m P.55
Address module
m P.55
GF-BP
GFW-S
Bus control unit
m P.58
GF-NS
LCD directory
m P.55
Power supply
GF-10KP
Blank panel
m P.55
GF-MK
GF-1D
Digital keypad panel
m P.55
Concierge station
m P.57
Apartment station
m P.57
Desk-top stand
for GF-MK
m P.57
GF-1DK
Concierge call
apartment station
w/Panic call transfer
Use with GF-MK
m P.57
GF-10K
Digital keypad
m P.55
GFW-LD
PS-2410LD
m P.58
m P.58
Cabling
Long distance
adaptor
m P.59
PS-2410LC
Wiring
2.BUS
2.BUS
1P
1P
GF-1DK x 2
1P
1P
1P
R1
R2
GF-1DK
1P
1P
GF-1DK
1P
1P
1P
1P
1P
R1
R2
1P
1P
C
CE
C
CE
R1
R2
R1 GF-1DK
R2
1P
1P
C
CE
C
CE
O
K
KE
1P
1.BUS
1.BUS
3.BUS
C
CE
O
GF-BC
1P
1P
(NP)
1P
(NP)
1P
(NP)
R1, R2
1P
1P
1P
R1
R2
1P
R1
R2
1P
R1 +
R2 –
1P
R1 R1
R2 R2
1
M
PQ
L
PQ
V
O
9Z
WX
T
WX
T
U
F
6
N
8
R
3
E
J
M
G
J
l Bus line: Any number per system. Max. 50 stations per line.
1P, Non-polarized
D
G
GF-MK
C
5
I
K
7S
Y
0
GF-MK
L
H
ML
H
B2C
K5L
E3F
N6O
Y9Z
WX
B
4
H
O
Y
U8V
T
2
F
6
9Z
PQ
1
3
A
D
L
N
V
0
2.GF-MK
M
C
E
K
U
0
R7S
J
A
2
B
5
I
8
R
H4I
G
1P
1
4
H
7S
EL
EL
+
b
A
EL
EL
+
b
1P
N
D
GF-BC
N
1P
1P
MULTI-UNIT ENTRY SECURITY
GF-1DK
GF-1DK
GF-1DK
R1 x 2
R2
GF-1DK
1.GF-MK
M
l Bus line (MAX.) 50 stations per Line
l K, KE terminals; Mounted on GF-1DK only
l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry
closure contact.
N : PS-2410LD, PS-2410LC
50
Four-Wire Common Video System
ENTRANCE
5
RESIDENCE
100or250 GF Audio/Video
Entrance station modules
Entrance station
l Direct-select Call Button
l Digital Name Scrolling
l Camera Module
l Audio Module
l Direct-Select Keys
GF-VP
GF-DP
GF-1P
GF-2P
Camera panel
m P.55
Audio panel
m P.55
1-call panel
m P.55
2-call panel
m P.55
GF-VA
GF-DA
GF-3P
GF-4P
Camera module
m P.55
Audio module
m P.55
3-call panel
m P.55
4-call panel
m P.55
l Audio Module
Audio, Camera & Digital Keypad &
LCD Directory
Audio, Camera & Direct-select
12-call buttons
Frame & Box
Assemble the following in as many rows as required.
GF-2F 2-module Front frame
GF-2B 2-module Back box
GF-3F 3-module Front frame
GF-3B 3-module Back box
GF-SW
Call switch module
m P.55
PP.56
Features
Communication network
MULTI-UNIT ENTRY SECURITY
l Fully modular Entrance station. Vandal-resistant construction
l Two single-pair cables run throughout system
l Second monitor or audio station can be installed
l Call tone off at individual station with blinking LED indicator
l Door release & external light, Bus line-controlled
l Optional functions: Doorbell at individual door. Auto-Entry (auto
door strike)
l User-optional feature, using SERVICE button
GF-1MDK x 2
GF-1MDK
Capacity
l 1 or 2 apartment stations within a residence
l Entrance station panel : 100-call sized
l Direct-select call button : Total 150 apartment stations incl. second stations
l Digital name scrolling : Total 250 apartment stations incl. second stations
GF-1MDK
O
1.
M
1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
O
9Z
V
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
2.
GF-MK
5.
1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
V
O
9Z
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
GF-MK
J Callig & communication K PANIC CALL sounding & Answer-back.
GF-MK; Concierge station must be used w/GF-1MDK.
I Doorbell O Panic call switch, available with GF-1MDK only
Bus line-controlled; M Door Release L Light
51
Apartment station
l Digital Name Scrolling
Concierge station
Bus control unit
Lineup
GF-BC
Bus control unit
m P.58
GF-NSP
LCD directory
panel
m P.55
GF-NS
LCD directory
m P.55
GF-VBC
GF-4Z
Video control unit
m P.58
4-apt. Bus junction unit
m P.58
GF-nH
GF-nHB
Rain hood
m P.56
Hooded surfacemount box
m P.56
GF-AP
GF-AD
Address panel
m P.55
Address module
m P.55
GFW-S
GF-BP
Power supply
GF-10KP
GF-1MD
Digital keypad
panel
m P.55
GF-MK
Apartment station
m P.57
Desk-top stand
for GF-MK
m P.57
Concierge station
m P.57
GF-1MDK
Concierge call apartment
monitor station
w/Panic call transfer
Use with GF-MK
m P.57
GF-10K
Digital keypad
m P.55
PS-2410LD
PS-2410LC
m P.65
m P.58
Cabling
Blank panel
m P.55
Wiring
1.BUS
2.BUS
GF-1MDK
1P x 2
SW1
A
GF-1MDK (x 2)
OUT
B
IN
B1 B2
B1 B2
R1 R2
R1 R2
OUT
IN
C CE
K KE
GF-1MDK
1P x 2
2
OUT
SW1
O
B
A
IN
2
SW1
GF-1MDK
1P x 2
OUT
B
A
IN
B1 B2
B1 B2
R1 R2
R1 R2
B1 B2
B1 B2
R1 R2
R1 R2
OUT
IN
C CE
K KE
O
OUT
IN
C CE
K KE
O
GF-1MDK
2
OUT
SW1
GF-1MDK
B
A
IN
R1 R2
R1 R2
B1 B2
B1 B2
OUT
IN
C CE
K KE
O
1P x 2
GF-1MDK
VIDEO
AUDIO
1.BUS
2
GF-VBC
1. ~ 6. BUS(Video)
6
1P x 2
VIDEO
1P x max.6
VIDEO
AUDIO
AUDIO
(1)
1P
1P
1
A
2
B
G
J
L
1P
1
C
5
I
K
L
M
PQ
8
R
V
O
9Z
WX
T
U
F
6
N
7S
3
E
4
H
J
WX
T
Y
2
B
O
9Z
G
PQ
V
0
D
M
U
F
6
N
8
R
A
5
I
K
7S
3
E
4
H
Y
+ B1B2 B1B2 B1B2 B1B2 B1B2 B1B2
– OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
N
+
–
GF-VBC
IN5
IN3
IN2
R1, R2
IN1
N
2.GF-MK
R1 R1
R2 R2
GF-MK
A1A2 A1A2 A1A2 A1A2 A1A2
1
2
B
4
H
C
K
L
PQ
8
R
V
O
9Z
WX
T
U
F
6
N
7S
3
E
5
I
M
N
N
IN4
R1 +
R2 –
GF-BC
1
J
N
+
N
0
2
G
GF-BC
3
D
GF-VBC
4
A
1P x 2
C
D
1P x 2
5
MULTI-UNIT ENTRY SECURITY
O
Y
0
GF-MK
GF-MK
A1A2
R1 R2
GF-DA
Audio/Video trunk lines
l There are methods of installing audio/video trunk lines, i.e. Monitorto-Monitor or homerun to GF-4Z’s. The two methods may be used
within a system. But do not mix two methods on a same trunk line.
l BUS (Audio/Video) Line; Up to 6 lines. Two single-pair cables
common. Max. 25 Monitors per Line.
A1A2
R1 R2
GF-DA
(1) Required when the second GF-1MDK is installed within an apartment.
l K, KE terminals for Panic call switch; GF-1MDK only.
l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry
closure contact.
N : PS-2410LD, PS-2410LC
52
Two-Wire Bus System
ENTRANCE
8
RESIDENCE
4,800 GF Multi-Tower
Multi-Tower System
GF-GD-TS
Central entrance station
(Audio only)
GF-GMK
Central security guard
station
VGX-D-YBOX
Built-in back box
GF-6GX24-2
Central control unit
Power supply
PS-2410LD (GF) m P.58
PS-1215DIN (Central)
Features
Communication network
l Max. 24-Tower, 4,800-Residence System
l Two-pair cable throughout GF standard Single-tower system
l Panic call annunciation to Central & Single-tower security guard
stations
l Audio only Central entrance stations with two talk channels
C
GF
GF-1MDK
MULTI-UNIT ENTRY SECURITY
AIPHONE
GF-MK
A
GF-GD-TS
Capacity
Multi-tower
No. of Towers
Central security guard station
Central entrance station (audio)
Residential monitor station
Single-tower
Security guard station
Entrance station (audio/video)
Resodential monitor station
53
24 bldgs.
4 pcs
8 pcs
4,800 pcs
1 pce
4 pcs
250 pcs
B
GF-GMK
(A) COMMON ENTRANCE (B) SECURITY GUARD (C) Single-tower
RESIDENTIAL MONITOR
Doorbell
PANIC CALL
P Callig & Answering J Callig & communication (both ways)
X Door strike Y Panic call
*Not available in Europe, Australia, nor New Zealand
Single-Tower System
GF Entrance station
w/Digital name scrolling
m P.55
GF-MK
GF-1MDK
GF-1DK
Concierge call apartment
monitor station
(w/Panic call transfer)
m P.57
Apartment station
(concierge call)
w/Panic call
transfer
m P.57
Concierge station
m P.57
GF-GTX
Single-tower control unit
Wiring
Unit dimensions
GF-GD-TS
5P
GF-GTX
5P
GF-GTX
5P
GF-GTX
5P
PS
PS
GF-GD-TS
3P
PS
PS
PS
300
GF-GMK
GF-GTX
3P
PS
PS
GF-GD-TS
3P
5P
GF-GTX
5P
PS
GF-GTX
5P
PS
PS
PS
GF-GMK
PS
20 80
98
340
GF-GTX
5P
GF-GMK
(1)
(2)
107
106
GF-GTX
3P
GF-GTX
5P
GF-GTX
5P
GF-GTX
5P
GF-6GX24-2
3Px 8
PS
PS
PS
PS
1
2
4
5
7
8
9
0
C
320
GF-GTX
5P
230
PS
MAX.
300m
3
6
3Px 4
PS
GF-GD-TS
3P
MAX.
300m
PS
GF-GTX
5P
GF-GTX
5P
PS
PS
PS
GF-GTX
PS
GF-GMK
PS
GF-GD-TS
3P
GF-GTX
250
5P
230
80
3P
GF-GD-TS
3P
GF-GD-TS
3P
GF-GTX
5P
GF-GMK
5P
PS
GF-GTX
5P
PS
GF-GTX
5P
GF-GTX
MULTI-UNIT ENTRY SECURITY
GF-GTX
460
C
1Km
350
A
GF-GD-TS
3P
GF-6GX24-2
2.5Km
GF-GMK (1) Desktop (2) Wall mounting
5P
3P
1Km
PS
PS
B
PS
GF-GTX
5P
PS
GF-GTX
5P
PS
GF-GTX
5P
GF-GTX
5P
PS
PS
PS
PS
PS
1Km
Multi-tower trunk line
(A) Common entrance 300m/unit (farthest). 1Km(cumulative All stations)
(B) Central security guard 300m/unit (farthest). 1Km(cumulative All stations)
(C) Tower interface adaptor 1km/unit (farthest). 2.5Km(cumulative All units)
C : PS-1215DIN
Specifications (GF Multi-tower)
Power source & consumption GF-GGX24-2: 12V DC, 24W (Standby 16W)
GF-GD-TS: 12V DC, 200mA (100mA)
GF-GMK: 12V DC, 350mA (120mA)
GF-GTX: 12V DC, 2.0W (1.5W)
PS-1215DIN
Power supply
Electric tone, Central entrance to Residence
Communication
Twisted pairs CPEV, 0.9mm dia.
Cable
5 twisted pairs, CPEV0.9mm, CCU ~ GF-GTXs
Wiring
3 twisted pairs, CPEV0.9mm, CCU ~ GF-GMKs
3 twisted pairs, CPEV0.9mm, CCU ~ GF-GD-TS
Distance
300m/0.9mm, CCU ~ GF-GD-TS (8 pcs total 1Km)
300m/0.9mm, CCU ~ GF-GMK (4 pcs total 1Km)
1Km/0.9mm, CCU ~ GF-GTX (4 bldg. total 2.5Km per block)
54
Two-Wire Bus System
Entrance station modules & panels
System layout example
Audio Module
. AUDIO
#2
Specifications (GF-DA)
#1
1P
1P
AIPHONE
GF-DP
GF-DA
Audio panel
Audio module
Call switch Module
Consumption
Entrance station
Wiring
Type of cable
1P
AIPHONE
H
H
M
AUDIO
M
GF-BC
N
Mounting
Housing
Weight
. AUDIO & VIDEO
#2
30mA
5
Single-pair cable common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
dia.
Box and front frame GF-2B,3B
and GF-2F,3F
Fire-retardant Plastic
Approx. 180g
#1
1P
1P
Specifications (GF-SW)
1P
Capacity
Lighting
Housing
Weight
1P
GF-1P
GF-2P
1-call panel
2-call panel
AIPHONE
AIPHONE
H
H
M
GF-3P
GF-4P
3-call panel
4-call panel
GF-VBC
GF-BC
N
N
M
#2
#1
1P
1P
GF-SW
Specifications (GF-VA)
Consumption
Entrance station
Wiring
Type of cable
. AUDIO & VIDEO + GF-NS
1P
1P
Call switch module
N
Housing
Weight
Camera Module
100-call buttons
Yellow LED
Fire-retardant Plastic
Approx. 90g
140mA
5
Two single-pair cables common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm
dia.
Fire-retardant Plastic
Approx. 140g
N : PS-2410LD, PS-2410LC
Specifications (GF-NS)
Power source
Unit dimensions
GF-VA
Camera panel
Camera module
. GF-DP
(1)
Consumption
Wiring
Type of cable
7.9
110
AIPHONE
Digital name scrolling module
225
95.2
135
(2)
GF-NSP
GF-NS
Housing
Weight
Housing
Fire-retardant Plastic
Lighting
Yellow LED
Weight
Approx. 90g
44
GF-10K
Digital keypad panel Digital keypad
44
Specifications (GF-10K)
16
135
GF-10KP
16
AIPHONE
LCD directory panel LCD directory
320
MULTI-UNIT ENTRY SECURITY
GF-VP
Specifications (GF-AD)
(3)
Weight
Approx. 90g
E
N
O
C
L
Yellow LED
9
Z
P
W
J
G
I
3
8
T
U
Fire-retardant Plastic
Lighting
6
K
M
S
B
5
Housing
F
2
A
H
7
D
4
V
1
Q R
AIPHONE
225
Lineup
X Y
0
270
GF-AP
GF-AD
GF-BP
Address panel Address module Blank panel
55
DC 24V, supplied by a power
supply PS-2410LD, LC
0.07A
Two single-pair cables common.
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm
dia.
Fire-retardant Plastic
Approx. 150g
16
44
(1) Audio, 4-call (2) Audio, 8-call (3) Audio/Video + Name scroll
Entrance station mounting accessories
Mounting
Front frame & back box
. GF-nH
GF-3B
42
W
GF-DA
. GF-nHB
W
GF-DP
GF-3F
(4)
H
H
65
22
(3)
GF-3F
GF-2B
GF-3B
2-module
front frame
3-module
front frame
2-module
back box
3-module
back box
(5)
GF-SW
GF-4P
GF-2F
85
(2)
(1)
H
W
GF-102H/HB
243
155
GF-202H/HB
243
290
GF-103H/HB
338
155
GF-203H/HB
338
290
GF-303H/HB
338
425
(1) Tamper-proof screw & screwdriver (supplied with GF-BC) (2) Module-mounting bracket (supplied with
GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box
1.
Hooded surfacemount box
Rain hood
3.
200
mm
GF-nHB
GF-nH
(1)
2.
(1)
295
mm
25mm
25mm 25mm
44mm
W
(2)
44mm
(2)
W
1. Two 2-module back boxes
2. Three 3-module back boxes
(1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
GF-2B/3B
x1
x2
x3
x4
x5
x6
x7
x8
x9
W
110
245
380
515
650
785
920
1055
1190
3. Back box total width (mm)
Entrance station components
AUDIO
(1) 4.
8.
AUDIO / VIDEO
AIPHONE
(1) 4.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
GF-VA
GF-VP
GF-DA
GF-DP
GF-SW
GF-4P
GF-2P
GF-2F
GF-2B
GF-3F
GF-3B
GF-BP
GF-AD
GF-AP
GF-NS
GF-NSP
GF-10K
GF-10KP
AIPHONE
8.
AIPHONE
16.
AIPHONE
12.
AIPHONE
20.
AIPHONE
16.
AIPHONE
30.
AIPHONE
AIPHONE
20.
AIPHONE
AIPHONE
30.
AIPHONE
GF-NS
GF-10K
40.
GF-NS
GF-10K
40.
AIPHONE
AIPHONE
AIPHONE
4.
1
1
1
1
1
1
-
4.
1
1
1
1
1
1
1
1
8.
1
1
2
2
1
1
8.
1
1
1
1
2
2
2
2
-
12.
1
1
3
3
2
-
12.
1
1
1
1
3
3
2
2
16.
1
1
4
4
2
2
16.
1
1
1
1
4
4
2
2
20.
1
1
5
5
2
2
20.
1
1
1
1
5
5
3
3
30.
1
1
8
7
1
3
3
30.
1
1
1
1
8
7
1
4
4
40.
1
1
10
10
4
4
40.
1
1
1
1
10
10
4
4
GF-NS, GF-10K
1
1
1
1
GF-NS, GF-10K
1
1
1
1
2
2
-
-
-
-
-
-
-
1
-
-
1
-
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
1
1
1
1
1
1
1
MULTI-UNIT ENTRY SECURITY
AIPHONE
12.
(1) Number of calling button (2) Camera (3) Audio (4) Call switch (5) 2-module Front frame (6) 3-module Front frame (7) Option (8) Digital name scroll
56
Two-Wire Bus System
Residential station
Residential audio station
GF-1D
Apartment station
Features
Specifications (GF-1D, GF-1DK)
Auto-Entry (Auto door strike)
Setting required.
Call tone from Entrance and
Doorbell are differentiated.
Power source
DC 24V, supplied from 2-wire
Bus control unit GF-BC
Consumption
Total station
Wiring
16mA
250 residential stations
Single-pair cable common
Type of cable
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
Trunk line
GF-1DK
AUDIO
Concierge call apartment
station
w/Panic call transfer
(Photo)
GF-1D
GF-1D
1P
1P
1P
GF-BC
N
AUDIO &
VIDEO
AUDIO &
VIDEO
1P x 2
GF-1MDK GF-1MDK
GF-1MDK
1P x 2
1P x 2
M
Residential monitor station
Fire-retardant plastic
Approx. 370g
Specifications (GF-1MD, GF-1MDK)
Power source
M
GF-1MDK
M
Apartment station
DC 24V, supplied from Bus
control unit, GF-BC & GF-VBC
M
Consumption
356mA
M
Total monitor station150 GF-1MD(K)’s.
1P x 2
1P x 2
GF-1MDK
1P x 2
GF-1MDK
GF-1MDK
1P x 2
250 GF-1MD(K)’s w/GFW-VBC,
M
Expander video control units.
1P x 2
l BUS line (audio); Max. 50 stations
l Video line; Max.25 Monitors either via max.
6xGF-4Z’s or Monitor to Monitor. Do not mix two
wiring methods on a same trunk line.
MULTI-UNIT ENTRY SECURITY
DOORBELL BUTTON
(option)
Housing
Weight
1P x 2
GF-1MD
Video monitor
10cm direct view flat CRT
Wiring
Two Single-pair cables common
Type of cable
2-conductor cable solid copper
& non-braided, polyethylene
Unit dimensions
insulation, 0.65mm dia.~1.0mm
GF-1DK, GF-1D
GF-1MDK, GF-1MD
dia.
89
60
83.5
60
83.5
210
GF-1MD
200
Concierge call apartment
monitor station
(w/Panic call transfer)
(Photo)
dia.
Wall-mounting only
60mm or 83.5mm guided
M
1P
GF-4Z
GF-1MDK
Mounting
Electrical box
1P
DOORBELL BUTTON
(option)
216
63
Mounting
Wall-mounting only
Electrical box
60mm or 83.5mm guided
Housing
Fire-retardant plastic
Weight
Approx. 1200g
69
Concierge station
For either audio or audio/video system
Trunk line
Specifications (GF-MK)
GF-1DK
GF-1DK
1P
1P
1P
1P
O
O
Consumption
LCD display
Wiring
Type of cable
50mA
Max. 16 letters for names
Two Single-pair cables common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
dia.
Wall-mounting or Desk-top
mounting on GFW-S
60mm or 83.5mm guided
Fire-retardant plastic
Approx. 900g
1P
GF-1DK
1P
O
Mounting
1P
Electrical box
Housing
Weight
GF-1DK
1P
1P
O
GF-MK
Concierge station
1P
H I
3
B C
5
J
N O
7
S
K L
N O
9
X Y
Z
Z
W
U V
E F
6
8
T
Q R
X Y
M
W
0
GF-MK
GF-MK
60
83.5
0
210
T
9
P
4
6
G
S
2
E F
D
K L
U V
1
3
B C
5
8
A
P
7
Q R
M
57
H I
J
Desk-top stand
GF-BC
4
G
GFW-S
2
D
1P
GF-MK
1
A
1P
Unit dimensions
1P
N
O Panic call switch
l Must be used with GF-1DK or GF-1MDK in
Concierge station application.
215
69
Bus & Video control units
System layout example
AUDIO
Specifications (GF-BC)
MAX.50
GF-1DK
1P
1P
Power source
MAX.50
1P
GF-1DK
GF-1DKGF-1DK
1P
1P
1P
Mounting
Weight
MAX.50
1P 1P
1P
BUS(AUDIO)
Specifications (GF-VBC)
1P
1P
1P
1
2
B
A
3
E
4
G
H
C
D
5
I
K
J
N
7S
PQ
8
R
O
1
Y
4
G
0
2
H I
P
6
8
W
T
U V
E F
N O
Power source
DC 24V,m supplied by a power
supply PS-2410LD, LC
1,100mA.
Single-pair cable common.
DIN rail
Approx. 260g
9
X Y
Z
S
K L
M
7
Q R
3
5
J
Bus control unit
B C
D
9Z
WX
V
A
T
U
F
6
L
M
GF-BC
1P
1P
Consumption
Wiring
Type of cable
GF-1DK
1P
GF-1DK
1P
DC 24V, supplied by a power
supply PS-2410LD, LC
900mA.
Single-pair cable common.
2-conductor cables solid copper &
non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm dia.
DIN rail
Approx. 450g
0
GF-MK
& GFW-S GF-MK
#4
#5
#3
GF-BC
1P
N
1P
H
#2
M
Consumption
Wiring
Mounting
Weight
Specifications (GF-4Z)
Wiring
Type of cable
#1
Two single-pair cables common.
2-conductor cable solid copper &
non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm dia.
Approx. 450g
AUDIO / VIDEO + GF-NS
GF-1MDK
GF-1MDK
1P x 2
M
GF-4Z
1P x 2
Weight
M
Wiring distance
GF-VBC
Video control unit
1P x 2
1P x 2
M
1P x 2
GF-1MDK
GF-1MDK
BUS(Audio / Video) MAX.6
1
3
2
5
4
6
1P x 2
GF-BC
1P
GF-VBC
1P
1Px2
1P
1Px2
1Px2
1P
1P
1P
N
1P
1Px2
1Px2(*)
N
(10)
GF-4Z
4-apt. Bus junction unit
AUDIO system
l Max. 250 Apartment stations l Max. 5 Entrance stations
l MAX 100-call panel l Max. 3 Entrance stations per BUS line
Audio/video system
l Max. 250 Apartment monitor stations
l Max. 5 Entrance camera stations
l Power supply for five GF-NS’s
1Px2(*) : 1P for Audio & 1P for power supply of GF-NS’s
M Optional door strike at each entrance
Unit dimensions
GF-BC, GF-VBC, GF-4Z
122.5
61
MULTI-UNIT ENTRY SECURITY
1P
N
N
Distance (Diameter of wires)
GF-BC to Distribution point
5m (0.8mm)
Distrib. point to Entrance station 300m (0.8mm)
Distrib. point to GF-1K(farthest) 300m (0.8mm)
GF-VBC to farthest GF-1MDK 1 per resid. line
100m (0.8mm), 150m (1.0mm)
GF-VBC to farthest GF-1MDK 2 per resid. line
50m (0.65mm), 100m (0.8mm),
150m (1.0mm)
GF-VBC to Entrance station(GF-VA, Video)
100m (0.8mm), 150m (1.0mm)
GF-BC, VBC/A to ea. Power supply
5m (0.8mm)
GF-NS/A to Power supply
300m (0.8mm), 300m (1.0mm)
MAW-B to Entrance station
300m (0.8mm)
Total wiring distance(R1, R2)
2.5km (0.8mm)
108.5
M
Power supply
Unit dimensions
Specifications
PS-2410LD
PS-2410LC
Power supply
PS-2410LD PS-2410LC
Power source
AC220-240V 120V
164
Secondary output voltage & current
66
95
RD
PS-2410LD
PS-2410LC
DC24V, 1A DC24V, 1A
BK
RD : Red, BK : Black
58
Two-Wire Bus System
Long distance adaptor(Audio)
Wiring
Sub-Bus No.1
Sub-Bus No.2
Sub-Bus
Accumulated total wiring
Apartment
station
distance 2500m
max.100/Sub-Bus
Farthest Apartment
1P total 250/system
1P
station max.150m
GF-BC
Sub-Bus No.9
1P
GF-BC
N
GFW-LD
GFW-LD
Sub-Bus No.10
1P
GF-BC
GFW-LD
N
GFW-LD
1P
1P
GF-BC
N
1P
Long distance adaptor
for audio
1P
1P
Common Bus
Accumulated
total wiring
distance 2000m
Wiring distance
GF-DA-Apartment
station
GF-MK-Apartment
station
max. 600m
N
GFW-LD
1P
1P
1P 1P
1P
1P
1P
GF-MK
GF-MK
GF-BC
1
3
E
2
B
F
5
I
K
L
M
M
PQ
PQ
V
F
O
9Z
WX
T
U
WX
T
8
R
Y
3
6
N
7S
O
9Z
C
E
4
H
6
J
J
L
N
V
G
G
K
U
D
D
Max.5
C
5
I
8
R
A
A
N N
1
2
B
4
H
7S
Y
0
0
Max.2
*Communication method : Auto-voice actuation
Expanded video control unit
Unit dimensions
Wiring
GFW-VBC
5
VIDEO BUS
2
3
4
GFW-VBC, GFW-LD
MAX.6 x GF-4Z's GF-1MDK
GF-4Z
1P x 2
1
108.5
6
+
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
+ –
122.5
OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
IN1
GF-1MDK
B1 B2
GFW-VBC
Expander video control
unit
GF-VBC
5
6
Power source
VIDEO BUS
4
3
2
1
AUDIO
BUS
N
+ –
+ –
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
Type of cable
R1 R2
+ –
N
N
DC 24V, supplied by a
power supply
PS-2410LD, LC
0.9A.
Two single-pair cables
common
2-conductor cable solid
copper & non-braided,
polyethylene insulation,
0.65mm dia~1.0mm dia.
Standard & Expanded video wiring (w/GFW-VBC) (1) Required when a second GF-1MD is installed in an apartment(s).
System layout example
6~11
1.
1~5
6~11
2.
1Px2 1Px2 1Px2 1Px2 1Px2 1Px2
GFW-VBC
1~5
IN
1P
150m
150m
150m
1P
N
1P
150m
MULTI-UNIT ENTRY SECURITY
GF-BC
1Px2 1Px2 1Px2 1Px2 1Px2 1P
GF-VBC
AUDIO
N
AUDIO BUS
Option
MAW-B
Auxiliary light control relay
for entrance light
W-DIN11
DIN mounting rail
for GF-BC, GF-VBC,
GF-4Z, GFW-VBC
GFW-LD
N
2
N
1P
GF-VBC
GFW-VBC
GF-BC
1P
VIDEO BUS
2
1P
1. Increase wiring distance to the farthest monitor stations
1~5 Standard Bus lines 6~11 Expanded Bus lines
59
Consumption
Wiring
R1,R2
OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
IN5 IN4 IN3 IN2 IN1
61
Specifications
N
(1)
–
GF-BC
IN
VIDEO 2
1P
150m
2. Increase Video trunk lines
N
VIDEO 1
N
AUDIO
Two-Wire Electric Lock Door Phone
ENTRANCE
RESIDENCE
4 DA-4DS
1
Entrance station
Lineup
Residential station
Electric door
strike
(locally available)
DA-2DS
DA-4DS
2-call door station
4-call door station
DAR-1
Call extension
DA-1MD
Master station
DAW-P
Power supply
PT-1211D
PT-1211C
DA-2DG
DA-4DG
2-call door station
4-call door station
Features
Door station
mounting plate
(83.5mm)
m P.106
Wiring
310m / 1.0mma
155m / 1.0mma
DA-4DS
DA-4DG
M
DA-1MD
2
2
DA-1MD
2
P
P
DA-1MD
2
2
P
P
DA-1MD
2 DAR-1
2 AC15
(1)
Communication network
DA-1MD
DA-1MD
DA-1MD
DA-1MD
DA-4DS,
DA-4DG
(2)
D
Electric door 1 E
strike
2 D
E
3 D
E
4 D
E
M
Electronic tone. Direct select ring.
~
~
D
E
L
L
P
~
~
AC15
~
~
AC15
~
~
AC15
PT-1211D/C
D
E
P
P
D
E
D
E
P
S
SE
Unit dimensions
DA-2DS,G
DA-4DS,G
(3)
22
DA-1MD
61
175
DA-1MD
DA-1MD
DAR-1
(1)
DA-1MD
DA-4DS,
DA-4DG
2x2
200
100
SW
SW
DA-1MD
89
NP
2x2
2x2
MULTI-UNIT ENTRY SECURITY
l Two-wire system
l Door release wired to door station, requiring no power
transformer
l User-optional function button
l Call tone MUTE with indicator
l Call extension sounder
2x2
PT-1211D/C
(1) Ext. device Relay/Controller : User-optional function(AC18V, 40mA) (2) Door
release : Electric door strike or AC 16V, 20d or more (3) When a single
common power supply is used
Specifications (DA-4DS, G)
Power source
Power supply
Communication
Wiring
Distance
AC 15V.
PT-1211D, PT-1211C
Press and hold down Button to call.
2 wires, throughout system: PS - Master - Door - Door rlse.
PT-1211D/DR ~ Door rlse. 110m(0.6mma) 200m(0.8mma) 310m(1.0mma)
PT-1211D/DR ~ DA-1MD 55m(0.6mma) 100m(0.8mma) 155m(1.0mma)
60
Audio Entry Security
ENTRANCE
RESIDENCE
58 VC-M
1
Entrance station
Residential station
VC-0M
VC-4M
VC-6M
VC-10M
Blank entrance station
4-call entrance station
6-call entrance station
10-call entrance station
Power supply
PS-1225S
PS-1225UL
PS-1225
Electric door strike
(locally available)
VCH-8
VCH-16
8-call add-on panel
16-call add-on panel
Apartment station
Door release relay
m P.104
Other Panels
VC-1M,VC-2M&VC-8M
m P.106
Features
VC-K
RY-PA
Wiring
l Single entry 0 to 10-call panel
l Add-on 8 or 16 call panel(s)
l VC-K handset, one or two per residence
l Directory back illumination
l Single or larger panels up to 58 buttons
800m / 1.0mma
VC-6M
VC-K
VC-K
7
MULTI-UNIT ENTRY SECURITY
4+1x3
VC-K
M
H
Q
5
VC-K
7
(1)
VC-K
6
VC-K
6
5
4+1x6
2
T
VC-6M
VC-K
VC-K
VC-K
1
2
3
4
1
2
3
4
1
2
3
4
B
B
B
Communication network
VC-6M
VC-K
#1
M
Electric door
strike
YL
BK
1
2
3
4
1
2
3
4
+
+
+
+
+
+
B
+
---
1
2
3
4
B
B
T
L+
L---
#6
H
Direct select ring
61
1
2
3
4
(1) 4 common + 6 (no. of apartments) * Terminal 4 for door release
T : PS-1225S/UL H : AC transformer Q : RY-PA relay
BK: Black(2) YL: Yellow(2)
Entrance call panel
VC-26MY
26-call entrance station
VC-26MT
VC-58MT
26-call entrance station
58-call entrance station
VC-42MY
Lineup
VC-BBX
42-call entrance station
Wiring
Unit dimensions
(1)
VC-K
2
VC-K
VC-K
(2)
VC-K
VC-K
VC-M
(2)
(1)
60
156
83.5
VC-K
1
210
VC-4M
230
1
2
3
4
B
1
2
3
4
+
+
1
2
3
4
1
2
3
4
1
2
3
4
YL
68
Q
BK
B
+
80
61
T
B
+
+
-
1
2
3
4
B
VC-M, VCH
VC-26MY
VC-42MY
VC-26MT
VC-58MT
VC-BBX
B
T
Added variations
(1) Two VC-K stations per apartment. Calling is not available between room
stations 1 & 2.
(2) Use a local buzzer or bell rated less than 24V DC, 2.5A.
T : PS-1225S/UL Q : RY-PA relay
YL : Yellow(2) BK : Black(2)
H
260
260
260
487
487
–
(1)
W
186
339
492
186
339
–
D
2
2
2
2
2
–
H
230
230
230
457
457
264
(2)
W
156
309
462
309
309
190
D
68
68
68
68
68
52
Multiple box mounting; Keep a distance of 186mm between two box centers.
(1) Front panel (2) Back box
Specifications (VC-M)
Power source
Power supply
Communication
Wiring
Distance
MULTI-UNIT ENTRY SECURITY
Bz
12V DC, 80mA (intercom).
100mA (lamp)
PS-1225S, PS-1225UL
Electronic buzzer rings VC-K station(s). (Freq.: 600Hz.
approx.) Take (either) handset to reply. Single open
channel.
4 common + no.(residences), in loop.
VC-M ~ VC-K: 35d looped.
VC-M ~ power supply: 4d looped.
VC-M to VC-K 330m(0.65mma) 800m(1.0mma)
VC-M to PS-1215DIN 40m(0.65mma) 90m(1.0mma)
62
Open Voice Intercom
DOOR
ROOM
1
1 LEM-1DL
Door station
Master station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
LE-DA
LE-D
Sub station
m P.69
Sub station
m P.69
LEM-1DL
Master station
Electric door strike
(locally available)
LE-DL
Power supply
PS-1225S PS-1225UL
PS-1225 m P.106
Door station
m P.69
Features
Wiring
l Single door open voice access control system
l Adjustable tarnsmit (front) and tone volumes
l AC/DC power supply
(1)
300m / 0.8mma
LE-D
LEM-1DL
2
Communication network
2
M
LE-D
1
E
1
E
–
LEM-1DL
Electric door strike
12V AC,
350mA
(
M
EL
EL
+
–
)
H
(2)
LE-D
LEM-1DL
2
M
Unit dimensions
LE-D
1
E
–
LEM-1DL
2
1
E
Electric door strike
EL
EL
120
83.5
180
PWR
29
88
143
LE-DA
53.5
Specifications (LEM-1DL)
LE-DL
83.5
175
83.5
115
Power supply
Communication
10
120
25.5
Wiring
Distance
63
H/T
(1) Using Electric door strike door release
(2) Using door release of other manufacture rated : 30V AC/DC, 1A max.
Do not remove shorting link on LE-D. PWR : Power source
Power source
116
+
–
12~16V AC, 4VA.
12~24V DC, 200mA (24V).
AC transformer, PS-1225S, PS-1225UL
When called by tone, press TALK to reply. Press door
release button to release door, and press OFF for
standby.
2 wires, non-polarized (+2 for Electric door strike)
LEM-1DL to door 200m(0.65mma) 300m(0.8mma)
Open Voice Intercom
MASTER
SUB
3 LEM
1
Master station
Door station
Room sub station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
LE-D
Sub station
m P.69
LEM-1
1-call master
LE-A
Sub station
m P.69
LEM-3
3-call master
LE-DA
Sub station
m P.69
Power supply
PS-0602D PS-0602C m P.106
LE-AN
Privacy sub
m P.69
Features
Wiring
l Open voice communication
l Push-to-talk at master, hands free at remote
l LE sub stations: either door station or room sub station
l Voice volume control
300m / 0.8mma
LEM-1
LEM-1
LE-A
2
Communication network
LEM-1
LEM-1
1
E
LE-A
1
E
–
+
–
LEM-3
LEM-3
300m / 0.8mma
LE-D
300m / 0.8mma
LE-A
LEM-3
2x2
2
LE-A
LEM-3
LE-D
W
LE-AN
2
LE-AN
1
1
E
–
2
LEM-1; Tone or voice. LEM-3; Selective call w/tone or voice. Tone and LED from
sub
1
E
–
E
Unit dimensions
3
LEM-3
+
–
★ Do not remove shorting link on subs.
180
160
LEM-1, LE-A, LE-AN
W
1
E
–
W : PS-0602D, PS-0602C
Specifications (LEM)
131
51
143
LE-D
115
83.5
29
116
Power source
Power supply
Communication
83.5
LE-DA
120
88
53.5
10
Output
Wiring
Distance
6V DC, 200mA
PS-0602D, PS-0602C
Sub calls in w/tone and LED, 20 sec.
Depress selector button and press or release TALK
button. Sub called by tone or voice.
Reply hands-free.
350mW output, adjustable
2 parallel wires per sub, non-polarized
LEM to sub 200m(0.65mma) 300m(0.8mma)
64
Open Voice Intercom
STATION
11 LEF
Master station
Master station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
LEF-3
3-call master
LEF-5
LEF-10
5-call master
10-call master
LEF-5W
LEF-10W
5-call master
w/terminal box
10-call master
w/terminal box
LEF-10S
10-call master (all call)
Power supply
PS-1225S PS-1225UL PS-1225 m P.106
Features
Wiring
l Intermixable system with any number of masters and subs to
max. capacity
l Selective calling from any master with hands-free reply
l LEF surface and LEF-C semi-flush units can be intermixed
l Variety of sub stations are available
l Weather-resistant door stations (any number) with selective door
release
l System options: PanTilt door/monitor(s), All Call/Music/Chime
l Selective door release with LEF-5/10/10S (w/RY-PA)
Communication network
Door answering w/selective door release
300m / 0.8mma
LE-D #2
LE-D #1
C
2
3
4
5
1
E
M
E
LEF-5
–
–
YL
M
LEF-5
Electric door
strike
Electric door
strike
H
Selective call between inside stations. Answering & releasing door from any
inside station
Cabling
Models
LEF-3
LEF-5
LEF-10
LEF-10S
Capacity
4 stations
6 stations
11 stations
11 stations
Cable
9 wires
11 wires (+5: K1~K5*)
17 wires (+10: K1~K10*)
20 wires (+10: K1~K10*)
l K1 ~K10: Control terminals for video, door release.
l LEF-3 does not have L terminal.
l Door & inside sub stations can ring 2 or 3 LEF masters.
l LEF All-master trunk cable=5 (or 6) common + no.of LEF (& subs)
65
LEF-5
13
3
LEF-5
LE-D
LEF-5
13
RY-PA's
1
LE-D
LEF-5
4
3
C : PS-1225S, PS1225UL
Q
Q
1
C
3
4
5
1
2
C
4
5
1
2
3
E
R
Y
+
–
E
R
Y
+
–
E
R
Y
+
–
L
L
L
K4
K5
K4
K5
K4
K5
BK
H : AC transformer
Terminal 4 : for LE-D1, Terminal 5 for LE-D2.
YL : Yellow(2) BK : Black(2).
T
Door station
Lineup
Room sub station
LE-D
LEF-20(S)*, 20-call master (photo)
LEF-30(S)*, 30-call master
LEF-40(S)*, 40-call master
*Not available in Europe, Australia,
LE-A3
Sub station
m P.69
3-call sub
LE-A
Door release relay
m P.104
Sub station
m P.69
nor New Zealand
All call, music & chime
LEW-5
LEF-5 terminal
box
LEW-10
LEF-10 terminal
box
LEW-10S
LE-DA
LE-AN3
Sub station
m P.69
3-call privacy sub
LE-AN
LEF-10S terminal
box
BG-10C
All call, chime & music
adaptor
m P.69
Privacy sub
m P.69
Unit dimensions
LEF-3
Intermixed configuration
LEF-5, 10, 10S
3
BG-10C
LE-D
18
3
LEF-10S
LEF-10S LEF-10S LEF-10S
22
22
22
131
143
53.5
LE-A3, AN3
1
1
E
E
–
–
Electric door
strike
H
P1
P2
P3
+
–
YL BK
Q
Q
C
2
3
4
5
6
7
8
9
10
1
E
R
Y
+
–
L
1
C
3
4
5
6
7
8
9
10
2
E
R
Y
+
–
L
1
2
C
4
5
6
7
8
9
10
3
E
R
Y
+
–
L
1
2
3
C
5
6
7
8
9
10
4
E
R
Y
+
–
L
K9
K10
K9
K10
K9
K10
K9
K10
P1
P2
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
T
3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to
wire multiple subs (2 common + 1 per sub).
l LE-D call-in chimes on LEF stations.
l Only LEF-10S station can transmit all call.
l Match door release control terminals (Kn) with door selector #10 with K10, #9
with K9.
★ Remove a shorting link on LE subs.
T : PS-1225S, PS1225UL H : AC transformer Q : RY-PA
BG-10C
165
1
2
3
4
5
6
7
8
DB
DA
11
E
R
Y
+
–
M
51
55
190
180
M
Electric door
strike
206
180
LE-D
LE-A, AN
160
Wiring
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
RY-PA
Electric door
strike
(locally available)
250
143
77
53.5
Specifications (LEF)
Power source
Power supply
Communication
Door release
Selector switch
Wiring
Distance
12V DC, 300mA per LEF station.
PS-1225S, PS-1225UL
Sub calls in w/(chime) tone & LED, 20 sec.
Depress the LED lit selector button. Use
TALK/LISTEN switch. Master calls in w/tone or
voice (no LED lit). Reply hands-free. To call,
depress a selector, and call by voice or tone.
Contact: 30V DC, 0.1A (resistance load).
Contact: 12V DC, 30mA.
5 wires common + no .LEF (& subs) (all-master system)
2 wires per sub (single-master system).
* E to - link remains attached.
LE subs: 3 wires with the link removed (when intermixed)
Farthest LEF’s 200m(0.65mma)
300m(0.8mma)
Specifications (BG-10C)
Power source
All call transmit
All call receive
Chime tone transmit
Controls
Wiring
Distance
12V DC, 2.5A (music max. output).
1.5A(music, chime & all call). 0.1A standby
From LEF-3C, 5C, 10C & LEF-1C and LEF-10S
All LEF master station, and LE-C, CN
AUX R, E and AUX L, E
Music on/off. 11 selector switches of music &
chime, chime only or off.
19 wires max. BG-10C to LEF-10C.
3 wires to each LE-D, DA.
BG-10C to LEF-C 150m(0.65mma).
230m(0.8mma)
LE-D/DA to BG-10C 200m(0.65mma).
300m(0.8mma).
66
Open Voice Intercom
DOOR
ROOM
3
8 LEF-C
Door station
Master station
Sub station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
LE-D
Sub station
m P.69
LEF-3C
All call sub master
Sub station
*Not available in Europe
LEF-5C
LEF-10C
5-call master
10-call master
LE-BN*
Privacy sub
*Not available in Europe
LE-C*
Sub station
w/MUSIC receive
volume control
*Not available in Europe
LE-CN*
Power supply
PS-1225S PS-1225UL PS-1225
Privacy sub
w/MUSIC receive
volume control
*Not available in Europe
m P.106
Features
Wiring
l Intermixable system with any number of masters and subs to
max. capacity
l Selective calling from any master with hands-free reply
l LEF surface and LEF-C semi-flush units can be intermixed
l Variety of sub stations are available
l Weather-resistant door stations (any number) with selective door
release
l System options: PanTilt door/monitor(s), All Call/Music/Chime
l Selective door release with LEF-5/10/10S (w/RY-PA)
LEF-10C✕7
(20)
1
2
3
4
5
6
7
LE-D
1
LEF-10C
LE-D
LEF-10C
LEF-10C
E
–
LE-B
LEF-10C
LE-B
BK
YL Q
LE-B
H
Electric door strike
DA
–
9
10
11
E
R
Y
+
–
P1
P2
P3
+
–
DCIN
Power source
Power supply
Communication
LEF-1C
LE-B/BN
LE-C/CN
15.5
15
20
200
15.5
40
20
208
200
208
238
Output
153
3
3
1
C
2
3
4
5
6
7
8
9
10
1
E
R
Y
+
–
L
P1
P2
P3
1
C
2
3
4
5
6
7
8
9
10
2
E
R
Y
+
–
L
P1
P2
P3
1
2
3
C
4
5
6
7
8
9
10
3
E
R
Y
+
–
L
1
2
3
4
C
5
6
7
8
9
10
4
E
R
Y
+
–
L
1
2
3
4
C
5
6
7
8
9
10
5
E
R
Y
+
–
L
1
2
3
4
5
6
C
7
8
9
10
6
E
R
Y
+
–
L
1
2
3
4
5
6
C
7
8
9
10
7
E
R
Y
+
–
L
P1
P2
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
3
1
1
E
E
1
E
–
–
–
T
Specifications (LEF-C)
Unit dimensions
LEF-5C
LEF-10C
LE-B/BN✕3
20
20
20
20
BK : Black(2) YL : Yellow(2)
Intermixed configuration
Internal communication by Selective call. Sub calls in with tone & LED 20 sec.
LEF-3C
20
T : PS-1225S/UL Q : RY-PA relay H : AC transformer
LEF-10C
LEF-10C
LEF-10C
20
3 BG10C
Communication network
67
LEF-1C
LE-B*
3-call master
153
Door release
15.5
15
20
Selector switch
Wiring
Distance
12V DC, 300mA per station.
PS-1225S, PS-1225UL
Sub/door calls in w/tone & LED, 20 sec.
Depress the LED lit selector button. Depress
TALK/LISTEN switch. The LED stays lit while in
use. Single talk channel w/OCCUPIED lit.
800mW at 20d (receive).
500mW at 20d (transmit).
Contact: 110V AC, 1A.
24V DC, 1A. (on RY-PA output).
Contact: 12V DC, 1A. (K terminals)
5 or 6 common + no. all stations
Farthest LEF-C’s 200m(0.65mma)
300m(0.8mma)
Open Voice Intercom
Scheduled to stop production
DOOR
ROOM
3
8 LEF & MYW-P1L/P3L
Door station
Door adaptor
*Not available in Europe
Lineup
Master station
Door release relay
m P.104
MYW-P1L
Single PanTilt door
adaptor
MK-DBC
Video door station
MYH-CU
LEF-10
Video-monitor
10-call master
MYW-BA
Long distance
adaptor
m P.26
MYW-P3L
3 PanTilt door adaptor
m P.24
Power supply
PS-1225S PS-1225UL PS-1225 m P.106
PS-1820S PS-1820UL PS-1820 m P.107
Features
Wiring
LEF & MYW-P1L
l Single PanTilt door & two or more video monitors
l Electronic tone call-in
l Door selection & reply from any LEF master station
l Hands-free video monitoring
LEF & MYW-P3L
l 3 PanTilt doors & two or more inside monitors
l Selective door release activation
l Hands-free video monitoring
l Audio & video monitoring from any master/monitor station
l Surface & semiflush video monitors
75m / 1.0mma
100m / 1.0mma
MYH-CU &
MYH-CU &
MYW-P1L LEF-5
LEF-5
6
6
MK-DGC
2
M
A1
A2
U
2
LEF-5
Electric door
strike
T
M
Q
H YL BK
MYH-CU & LEF-5
C
2
3
4
5
1
1
C2
3
4
5
2
1
2
C3
4
5
3
1
2
3
C4
5
4
1
2
3
4
5
C2
+
–
E
R
Y
+
–
E
R
Y
+
–
E
R
Y
+
–
E
R
Y
+
–
E
R
Y
+
–
KA
L
K5
L
K5
L
K5
L
K5
L
K5
E
R
l Run audio & video wires in separate jacketed cables.
Specifications (MYW-P1L)
Unit dimensions
Power source
83.5
230
83.5
210
83.5
190
Power supply
Communication
MYW-P3L
Wiring
2-gang
155
80
42
155
ON
A1 B1
A2 B2
U1
U2
+
–
T : PS-1225S/UL U : PS-1820S/UL Q : RY-PA
H : AC transformer BK: Black(2) YL: Yellow(2)
LEF-5
MYH-CU
LEF-5
13
13
Door call-in with tone, LED and image. PanTilt viewing. Selective call between
rooms
MYW-P1L
LEF-5
13
A1 B1
A2 B2
U1
U2
+
–
DA
LEF-5
MYH-CU &
LEF-5
6
OFF
A1 B1
A2 B2
U1
U2
+
–
Communication network
MK-DGC
LEF-5
13
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
RY-PA
Electric door
strike
(locally available)
43
50
Distance
MYW-P1L: 18V DC, 500mA. 100mA standby.
MYH-CU: 0.4A. OA standby.
PS-1820S, PS-1820UL (video)
Door calls in w/tone & LED, 20 sec, image 45
sec. timed. Depress a lit selector button. Press
TALK button to reply. Communication times out
in 2-1/2 min. Press MONITOR button to
reactivate.
2 parallel wires to door, non-polarized.
6 wires in loop, MYW-P1L to monitors.
6 wires, MYW-P1L to LEF
MYW-P1L to door 100m(1.0mma)
MYW-P1L to MYH-CU1 75m(35m w/2
monitors)(1.0mma)
68
LE Sub stations & Accessories
Weather-resistant sub
Unit dimensions
LE-DA
88
Sub station
29
116
83.5
175
115
120
Sub station
10
25.5
120
LE-DL
Door station
LE-DA; 2-gang mounting
Room sub
Semiflush mount sub
*Not available in Europe
Unit dimensions
160
LE-A, AN
131
LE-A
LE-AN
Sub station
Privacy sub
LE-B
LE-BN
Sub station
Privacy sub
LE-C
LE-CN
Sub station
Privacy sub
51
LE-C & LE-CN: w/MUSIC receive volume control
3-call sub
All call sub master
Unit dimensions
Unit dimensions
LEF-1C
LE-B/BN
LE-C/CN
208
LE-A3, AN3
180
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
LE-D
LE-DL
83.5
LE-DA
83.5
LE-D
153
143
LE-A3
LE-AN3
3-call sub
3-call privacy sub
15.5
15
20
53.5
LEF-1C
All call sub master
All call/music/chime adaptor
Specifications (BG-10C)
Unit dimensions
Power source
165
BG-10C
250
BG-10C
All call, chime & music
adaptor
69
77
All call transmit
All call receive
Chime tone transmit
Controls
Wiring
Distance
12V DC, 2.5A (music max. output).
1.5A(music, chime & all call). 0.1A standby
From LEF-3C, 5C, 10C & LEF-1C and LEF-10S
All LEF master station, and LE-C, CN
AUX R, E and AUX L, E
Music on/off. 11 selector switches of music &
chime, chime only or off.
19 wires max. BG-10C to LEF-10C.
3 wires to each LE-D, DA.
BG-10C to LEF-C 150m(0.65mma).
230m(0.8mma)
LE-D/DA to BG-10C 200m(0.65mma).
300m(0.8mma).
Handset Intercom
MASTER
SUB
3 AT-406
1
Master station
Sub station
Lineup
External signaling
relay
m P.105
AT-406
Boxed set (white color)
AT-406P
Display pack
AT-406B/A
Boxed set (charcoal gray)
AT-206
AT-306
Master station
Sub station
Power supply
PS-0602D PS-0602C or Batteries
m P.106
Features
Wiring
l Handset master-sub intercom w/2 additional subs (optional)
l Battery status LED
l Batteries or DC power supply
l Buzzer or bell activation (optional)
AT-306
AT-206
2
AT-306
2
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
TAR-3
Boxed set
AT-306
2
Communication network
1
2
AT-206
W
AT-306 x 3
1
2
NP
NP
1
2
NP
1
2
+
---
W : PS-0602D, PS-0602C
Specifications (AT-406)
Master calls all the subs simultaneously, while the sub rings the master only.
Power source
Power supply
Unit dimensions
Communication
AT-206
AT-306
210
83.5
Wiring
Distance
80
6V DC, 150mA
PS-0602D, PS-0602C or Batteries gAAh (SUM-3)
x 4 pcs
Press CALL button to ring all subs. Pick up any
phone. Sub rings master only. Common talk.
2 parallel wires. non-polarized
2-station set 700m(0.65mma)
1000m(0.8mma)
AT-206 to subs 1~3 400m(0.65mma)
600m(0.8mma)
51
70
Handset Intercom
STATION
25 TD-H/B
Door station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Sub station
Master station
TD-1H/B
TD-3H/B
TD-6H/B
1-call sub
3-call master
6-call master
IF-DA
Door station
m P.34
DE-UR
Door station adaptor
Power supply
PS-1225S PS-1225UL PS-1225
m P.106
Wiring
Features
l All-master selective ring system
l Single-master configuration or intermix w/TD-1H/B
l Multi-conductor cable in loop
l Multi-talk channels
l Door station(s), audio or PanTilt video (max. 2)
l Zone paging, with or without talkback
l Music source connection. Page pretone cuts out music.
(2) Door station communication
230m /
0.8mma
1000m / 0.8mma
IF-DA
DE-UR
1
1
2
1
2
2
TD-6H/B
#1
10
#2
C
2
3
4
5
6
1
C
3
4
5
6
1
2
C
4
5
6
1
2
3
C
5
6
1
2
3
4
5
6
1
2
3
4
C
#3
10
#4
10
#5
10
Communication network
TD-12H/B
TD-12H/B
TD-12H/B
Paging
Speaker
TD-12H/B
1
2
1
2
TD-12H/B
TD-12H/B
IF-DA
All-master configuration. Station selector & CALL to ring any other station.
Wiring
(1) All-master configuration
C
D
D
D
D
D
D
D
+
–
+
–
+
–
+
–
+
–
+
–
+
–
A
B
T
1000m / 0.8mma
TD-12H/B
TD-12H/B
C
#1
#2
16
#3
16
#11
#12
16
16
15m / 0.8mma
#13
16
(3) Single-master configuration
TD-3H/B
C
2
3
4
5
6
7
8
9
10
11
12
1
D
+
–
1
C
3
4
5
6
7
8
9
10
11
12
2
D
+
–
1
2
C
4
5
6
7
8
9
10
11
12
3
D
+
–
T
1
2
3
4
5
6
7
8
9
10
C
12
11
D
+
–
1
2
3
4
5
6
7
8
9
10
11
C
12
D
+
–
1
2
3
4
5
6
7
8
9
10
11
12
C
D
+
–
l Install main cable of max. condctors allowed for each TD-H/B station model.
C : PS-1225S, PS-1225UL Terminal D : Door station
71
TD-1H/B
6
C
1
2
3
TD-1H/B
5
1
C
TD-1H/B
4
1
1
C
C
D
T
+
–
+
–
+
–
+
–
Terminal 5 for door 1, 6 for door 2. DE-UR’s should be powered by power
supply.
Privacy type
Lineup
Zone page
adaptor
For desk-top or surface wall
mounting, provide TDW-n/A
terminal box w/1.5m cord.
TD-6Z/A
6-call master station
TD-12Z/A
12-call master station
TDW-1/A
TD-1H/B terminal box
TDW-3/A
TD-3H/B terminal box
TDW-6/A
TD-6H/B terminal box
TDW-12/A
TD-12H/B terminal box
TD-12H/B
TD-24H/B
12-call master
24-call master
TDW-24/A
TD-24H/B terminal box
full trunk all-master
configuration
l No break-in call
l Zone page(s)
in lieu of station(s)
Power supply
PS-1225S PS-1225UL
PS-1225
RY-AC/A
External signaling
relay
m P.104
Specifications (TD-H/B)
Power source
Power supply
Communication
(4) Straight paging w/PD-1 (single-zone)
PD-1
(1)
TD-12H/B
3
(1)
T
Wiring
A
G
M
No.
C
DC12V
+
---
+
---
TD-H/B
+
---
Distance
T
(2)
Power source
Power supply
Communication
Wiring
Distance
PD-2
TD-12H/B
(1)
3
T
(1)
S
S
V
V
A
G
M
Power source
No.
DC12V
+
---
+
---
+
---
TD-H/B
T
T : PS-1225S, PS-1225UL
(1) Paging Speakers (2) Talkback speakers
Unit dimensions
PD-1
PD-2
TD-24H/B
210
83.5
83.5
138
210
TD-1H/B ~ TD-12H/B
TD-6Z/A, TD-12Z/A
91
73
100
12V DC, 90mA per channel
PS-1225S, PS-1225UL
Depress a selector and CALL to ring opponent.
3 + no. TD-Z/A in loop.
TD-Z/A stations 650m(0.65mma) 1000m(0.8mma)
(PD-1,PD-2)
(2)
C
12V DC, 70mA per station.
PS-1225S, PS-1225UL
Depress a station selector 1~12 and CALL (or CALL A)
to ring station 1~12 (or A1 ~ A12). Lift handset to reply.
Door calls in w/standard or faster(B) intermittent tone,
2-1/2 sec. Pick up and depress the selector assigned.
2 or 3 + no. TD-H/B in loop.
TD-1H/B: 4 wires. TD-3H/B: 7 wires.
TD-6H/B: 10 wires. TD-12H/B: 16 wires.
TD-24H/B: 28 wires.
TD-H/B stations 650m(0.65mma) 1000m(0.8mma)
DE-UR to door 150m(0.65mma) 230m(0.8mma)
(TD-Z/A)
(5) Paging with talkback w/PD-2 (single zone)
100
Zone page/talkback
adaptor
l 7 or 13 identical station,
m P.106
Wiring
PD-2
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
PD-1
Output
Paging & music
tone controls
Amp. input
Music input
Tuner output
Tape output
Talkback gain
Environmental noise
Paging
Wiring
PD-1: 12V DC, 300mA. PD-2: 12V DC,
48mA (talkback).
5Kd . Max. 1.5V
Treble 12dB at 10KHz. Bass 12dB at 100Hz.
AUX or PHONO 100K-500Kd, 0.12~0.5V
17Kd, 0.3V, 1KHz. for full output
Audio output: Range 100mV~1.2V, 10Kd or less
Low level output: Range 100mV~1.2V, 600d
40dB, 1KHz. at max. volume
Less than 80dB (phon)
Select an assigned selector # and page w/PAGE
button depressed. Release to receive reply
3 wires to TD-H/B via power supply
51.5
83
72
Handset Intercom
DOOR
Scheduled to stop production
ROOM
24 TD-H/B & MY-CU
1
Door station
Adaptor
*Not available in Europe
Master station
Lineup
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Electric door
strike
(locally available)
DE-UR
Door station adaptor
MK-DBC
Video door station
TD-12H/B
12-call master
MYW-BA
MY-CU
Long distance
adaptor
m P.26
Main video monitor
MYH-CU
Sub video-monitor
Power supply
PS-1820S
PS-1820UL
PS-1820 m P.107
PS-1225S
PS-1225UL
PS-1225 m P.106
Features
Wiring
l Single PanTilt door integration with three monitors, expandable
l Hands-free video monitoring or handset audio / video monitoring
100m /
1.0mma
MK-DBC
35m / 1.0mma
MY-CU
2
2
Communication network
U
MK-DBC
1A1 B1
1A2 B2
1A1 B1
1A2 B2
1A1 B1
1A2 B2
U1
U2
+
---
U1
U2
+
---
U1
U2
+
---
1
2
D1
E
D2
C
EL
EL
H
Electric door
strike
TD-12H/B
TD-12H/B &
MYH-CU
TD-12H/B TD-12H/B
16
16
16
DE-UR
TD-12H/B &
MYH-CU
TD-12H/B
16
DE-UR
A1
A2
TD-12H/B &
MY-CU
6
TD-12H/B
4
M
MYH-CU
MYH-CU
6
D
+
---
T
C
2
3
4
5
6
7
8
9
10
11
12
1
D
+
---
1
C
3
4
5
6
7
8
9
10
11
12
2
D
+
---
1
2
C
4
5
6
7
8
9
10
11
12
3
D
+
---
T : PS-1225S, PS-1225UL U : PS-1820S, PS-1820UL
1
2
3
C
5
6
7
8
9
10
11
12
4
D
+
---
H : AC trans.
Specifications (TD-H/B & MY-CU)
Power source
PanTilt viewing
Unit dimensions
Power supply
TD-12H/B & MY-CU(MYH-CU)
DE-UR
50
100
73
155
73
150
83.5
160
83.5
210
Communication
45
Door release
Wiring
Distance
TD-H/B: 12V DC, 70mA per station.
MY-CU: 18V DC, 0.9A max.
MYH-CU: 18V DC, 0.4A.
PS-1225S, PS-1225UL (TD-H/B).
PS-1820S, PS-1820UL (video).
Door calls in w/intermittent tremolo and image 45 sec.
Rings max. 12 stations. Pick up (any) handset and
depress a selector assigned to reply. Image stays on
2-1/2min. Reactivate w/MONITOR button.
DC30V or AC250V, 5A (resistance load)
2 parallel wires to door. 6 wires, monitors
MY-CU to door 50m(0.65mma) 100m(1.0mma)
MY-CU to MYH-CU1 35m(0.65mma) 75m(1.0mma)
MY-CU to MYH-CU1-2 17m(0.65mma) 35m(1.0mma)
Handset Intercom
STATION
90 YAZ-90-3W
Phone extension
YAZ-90-3W
Phone master station
Features
Wiring
l Microprocessor built-in intercom expandable to max. 90 stations
on 4-pair cable
l Up to 2.9km wiring distance
l Communication functions: Camp-on busy, secretary transfer, call
transfer
l Line-off trouble on one channnel does not affect the other
channels
2900m / 0.8mma
#10
4P
YAZ-90-3W
Communication network
YAZ-90-3W
YAZ-90-3W
YAZ-90-3W
YAZ-90-3W
#39
#40
3P
YAZ-90-3W
YAZ-90-3W
1
2
1
2
1
2
3
4
3
4
3
4
5
6
+
–
5
6
+
–
5
6
+
–
N
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Power supply
PS-2420S
PS-2420UL
PS-2420 m P.107
N
l Remove +,- wires between YAZ stations of different blocks.
Within a block locate a power supply in the center of cable run, and make groups
of max. 10 YAZ stations. As shown, connect +, - wires from the power supply to
each group's initial YAZ station.
N : PS-2420S, PS-2420UL
Specifications (YAZ-90-3W)
Power source
Power supply
Communication
Station to station communication in any pair
Unit dimensions
Line loop resistance
Wiring
Total wiring distance
94
83.5
230
YAZ-90-3W
24V DC, 150mA max. 20mA standby.
PS-2420S, PS-2420UL per 30-station block.
Dial 2-digit station # to ring other station with tone or voice pressing
PAGE. Privacy communication on each channel (max. 3).
Must not exceed 200d for farthest stations. 20d for power line.
4-twisted pairs (shielded) in loop.
Farthest YAZ’s 1900m(0.65mma), 2900m(0.8mma)
84
74
Integrated Security & Communication System
MASTER
8
DOOR
120 AX
Master station
COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM
AX-8MV
AX-8M
8-call color monitor master station
8-call audio master station
AX-16SW
16-call add-on selector
AX-8MV, AX-16SW
Features
l Up to 120 video entrance stations and 8 master stations
l All wired on CAT5 (4P), homerun cabling
l Total hands-free communication, auto-voice actuation
l Press-to-talk operation & optional headset available
l Masters available with 3-1/2 inch color TFT LCD
l 2 talk channels and 2 video channels
l Integrate with CCTV, PC, Access control, PBX system etc.
l Two type of All call among masters, Standard & Priority
l Audio/visual Monitoring
l Scan monitoring-Hands-free audio/visual monitoring
l Selective remote control (e.g. door release)
• PC remote monitoring & control
• PC programmable and event logging
Communication network
AX-DV
AX-8MV
AX-8MV
AX-DVF
PC programming
Video
signal
AX-DM
Monitor
Calling & communication (w/video from door)
Door release
75
*The design and specifications are subject to change without notice for improvement.
Preliminary Information
Door station
Central control unit
Color video
door station
COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM
AX-DV
AX-DM
AX-DVF
Audio door station
Mullion type
Color video door station
AX-084C
Central control unit,
4 masters and 8 doors
AX-248C
Central control unit,
8 masters and 24 doors
AX-320C
Add-on control unit,
32 doors
IF-DA
Door station
AX-DV-P
Color video
door station
w/space for embed
proximity reader
AX-DVF-P
Color video door station
w/space for embed
proximity reader
Power supply
PS-2420S PS-2420UL
PS-2420 m P.107
IE-JA
Door station
System Integration
Cabling
300m
300m
Video signal
CAT5
AX-8MV
AX-DV
Security Integration Software
Switch
camera
System log
PC
AX
System
AX-084C
CCTV
System
Remote
door release
Video
signal
AX-8MV
AX-DVF-P
CAT5
CAT5
Calling &
Communication
with video
Door
release
CAT5
AX-DVF
PS24
PS24
Door
release
history
CAT5
Remote door release
AX-DM
Monitor
Card ID
RS232C
Door
release
Access
Control
System
Access
Control
System
PC
Camera
CCTV
Switcher
Monitor
VCR
76
Integrated Security & Communication System
Master station
Features
COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM
AX-8MV
AX-8M
8-call color monitor master station
8-call audio master station
• Up to 8 door stations & 8 master stations
• Expandable up to 120 door stations
using AX-16SW
• 3-1/2 inch TFT color LCD (AX-8MV)
• Hands-free, press-to-talk, & optional
headset communication available
• Available in wall and desk top styles
• Master - to - master calling
• Standard & Priority All call available
among masters
• 2 talk channels & communication privacy
• 1 Video output (NTSC) (AX-8MV)
• Scan monitor, selective
remote control (e.g. door release)
• External talk switch connection available
(e.g. footswitch)
• Call extension
AX-16SW
16-call add-on selector
Door station
Audio
Features
Surface mount
Flush mount
Surface mount
• Vandal-resistant construction
AX-DV & AX-DV-P; Surface wall mounting
w/aluminum die casting panel
AX-DVF & AX-DVF-P; Flush mounting
w/stainless steel panel
• Space provided to embed proximity
reader (AX-DV-P & AX-DVF-P)
• Illumination LED's automatically turn on
in low light conditions w/color video
door stations
• Mullion surface mount (AX-DM)
AX-DV
AX-DVF
AX-DM
Color video door station
Color video door station
Audio door station
Mullion type
Video
Image view area
• AX-DV, AX-DVF
AX-DV-P, AX-DVF-P
65cm
IF-DA
Door station
Flush mount
77
AX-DV-P
AX-DVF-P
Color video door station
w/space for embed
proximity reader
Color video door station
w/space for embed
proximity reader
50cm
IE-JA
Door station
95cm
Central control unit
Features
AX-084C
Central control unit,
8 doors and 4 masters
AX-248C(photo)
Central control unit,
24 doors and 8 masters
AX-320C
Add-on control unit,
32 doors
(max. 3 units)
Unit dimension
AX-084C, AX-248C
AX-16SW
194
63
AX-DV-P
63
63
86
AX-DVF
AX-DVF-P
IF-DA
AX-DM
1-gang
160
295
246
245
195
130
AX-DV
194
88
85
420
426
88
85
175
AX-320C
420
426
175
AX-8M
175
AX-8MV
COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM
• Up to 8 doors & 4 masters w/AX-084C
Up to 24 doors & 8 masters w/AX-248C
Additional 32 doors available w/AX-032C
• Homerun cabling w/CAT-5 (RJ-45
connector) to stations
• PC programmable
• 2 BNC video output (NTSC) w/active
video signal
• Event logging and remote control available
(e.g. PC, Access control, CCTV)
• RJ-232 serial output
• 19 inch Rack mountable (2U)
98
28
IE-JA
25
146
100
43
2 45
25
22.5
115
100
2-gang
2 45
146
116
10
Components
Master station
Add-on
selector
AX-8MV/AX-8M
AX-16SW
AX-084C
AX-248C
AX-320C
1~8
1
-
1
-
-
9 ~ 24
1
1
-
1
-
25 ~ 40
1
2
1
-
1
41 ~ 56
1
3
-
1
1
57 ~ 72
1
4
1
-
2
73 ~ 88
1
5
-
1
2
89 ~ 104
1
6
1
-
3
105 ~ 120
1
7
-
1
3
Number of door station
Central control unit
Add-on
control unit
Note
Max. 4 Master stations
Max. 4 Master stations
Max. 4 Master stations
Max. 4 Master stations
78
Commercial Security Intercom
MASTER
SUB
64 1,024 AI-900
Master station
Sub station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
AI-RS150
AI-RS170
Substation, indoor
m P.81
Substation, outdoor
m P.81
AI-RS160
AI-RS180
Substation, indoor
m P.81
Substation, outdoor
emergency
m P.81
AI-MS900
Master station
m P.81
Features
l Flexible All-modular construction. Expansion options using
interface and function cards.
l Sub-to-master communication by voice switch or PTT-activated
talk-back. Master-to-master by full-duplex handsets.
l Four different substations for specific installation conditions.
l Provides a speaker and call button.
l Basic conversation plus full range of exchange functions,
including; Call forwarding, Scan monitoring, Emergency
conference, Conversation recording by way of external equipment,
and Paging by way of an external amplifier.
l Emergency calls from any substation at a central security control
room.
l Efficient voice recording at ea. master station.
l Used in combination with CCTV, access control, emergency
broadcast systems or other security equipment.
Communication network
(1)
AI-MS900
(2)
(3)
(6)
(4)
(5)
J Calling & Communication
(1) Speaker (2) Substations (3) Cordless Phone (4) Access Control (5) CCTV
(6) Personal computer. PC Link with programming and monitoring software.
79
Mounting accessories
AI-900MF wall-mounting
bracket
m P.82
AI-PU200
AI-900MF
Power transformer unit
m P.82
Main frame
m P.82
AI-PN100B
AI-PU200 rack-mount
panel
m P.82
Cabling
Wiring
AI-900MF
1. AI-MS900
(1)
AI-900RS
AI-900MS
CN1
CN1
CN2
CN2 CN3
AI-MS900
C/O
(2)
(3)
1-(1)
CN4
AI-900MF
AI-900MF
(4)
CN3
1-(1)
2. AI-900AL
Tel
AI-RS150~180
AI-MS900
2-(1)
2-(2)
2C
(5)
3. COM1
3-(1)
3-(3)
Modem
Program
PC
RS-232C
RS-232C
4-(1)
5. AI-900AF
l To double the size of the system;
Two Tie-line I/F cards are required (after that, add one I/F card
for each add’l main frame).
(1) Outside line (2) PC (for programming and system
maintenance) (3) External paging equipment (4) Substation
paging amplifier (5) shielded
AMP(1)
AMP(2)
COM1
INPUT
1P
OUTPUT
7-(1)
8. AI-900TI
2P
2P
2P
2P
2. AI-900MF
DC24V
IN
RS-232C
AI-900AF
CN4 AC-IN
CN5
CN8
AMP (16)
7. EXT. AMP.
9. AI-PU200
COM2
4-(2)
1P
1P
1P
15. LIN.
16. LIN.
2C
3-(4)
Operation
log PC
2. LIN.
CN6
RS-232C
4. COM2 3-(2)
Modem
l Basic system consists of; 4 Master stations, 64 Substations
and AI-900MF Main Frame with Interface Cards; Master(1),
Telephone(1), Substation(4), Outside line(1), Audio
function(1), and power unit(2).
1P
1P
1. LIN.
CN5
AI-900AL
CN1
AI-900TI
CN2
CN1
CN3
CN2
CN4
CN3
CN4
1P
1P
Tel
2P
CN4
AI-RS150
~ AI-RS180
6. AI-900RS
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
AI-YC303
AC-IN
24V DC
AI-PU200
4
4
~ (N, L)
AI-PU200
~ (N, L)
1. Master station Interface card 1-(1)To External Record device.
2. Telephone Interface Card 2-(1),(2)To External Recording device 1, 2.
3. Programming PC Connection COM1 3-(1) Via Modem. 3-(2) RS-232C cross cable. 3-(3) Direct
connection. 3-(4) RS-232C straight cable.
4. Operation Log PC Connection COM-2 4-(1) RS-232C cross cable. 4-(2) RS-232C straight cable.
5. Audio Function Card (for paging) AMP(1)-(16): Amplifier.
6. Substation Interface Card 1.LIN.-16.LIN.: LINE1-16.
7. External amplifier 7-(1) Paging amplifier.
.
8. Tie-Line Interface Card Exchange Interconnection 8-(1) 2C shielded (data line).
9. AI-PU200 Power Transformer.
80
Commercial Security Intercom
AI-900 Components
Master station
AI-MS900
Unit dimensions
74.5
216
Master station
Standard indoor substation
Features
Unit dimensions
The AI-RS150 is built with a black resin call
button and 14-gauge stainless steel. It can call
and converse with the programmed master
stations. All substation models are wired with a
shielded pair to the Main Frame.
120
2
AI-RS150
Substation, indoor
120
48.5
Indoor vandal resistant substation
Features
Unit dimensions
The AI-RS160 is made with heavy 11-gauge
stainless steel and a vandal resistant stainless
steel call button. Calls and communicates with
programmed master stations or telephones.
3
120
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
The AI-MS900 can initiate or receive calls from
programmed substations. Equipped with Pushto-Talk button for simplex communication, vox
operated handset, redial and transfer keys, and
eight auto-dial keys. Alphanumeric display for
caller ID. Two-twisted pair wiring to Main
Frame.
213
Features
AI-RS160
Substation, indoor
120
57.5
Outdoor vandal resistant substation
Features
Unit dimensions
The AI-RS170 is equipped like the AI-RS160,
but with the internal components protected
with a synthetic rubber sealant, making it
weather resistant. Calls and communication
with programmed master stations or
telephones.
AI-RS170
120
3
Substation, outdoor
120
57.5
Outdoor emergency substation
Features
Unit dimensions
The AI-RS180 is vandal and weather resistant
with a red aluminum call button, call assurance
LED, and an output to control an external relay.
Used for ADA compliance or emergency call
applications.
120
3
AI-RS180
Substation, outdoor
emergency
120
58.5
Box
SBX-2G Surface Mount 2-Gang Stainless Steel Enclosure
The SBX-2G is used for surface mounting the RS substations where flush mounting these substations is
not possible.
81
Main frame
Features
Unit dimensions
AI-900MF
Main frame
AI-900MF
443.7
The AI-PU200 has two 20V, 2.5A AC outputs.
One unit is required for every two AI-900RS
cards installed in the Main Frame.
420
483.6
The AI-PN100B is used to rack mount two
AI-PU200 power transformers side-by-side.
AI-PU200
AI-PU200
The AI-YC303 is used to wall mount the
AI-900MF Main Frame.
160
178
Power transformer unit
288.3
AI-PN100B
AI-PU200 rack-mount
panel
120
240V
250V 71A
OUTPUT
TO EX-200
TO FC-210
20V
2.5A 20V
2.5A
68
220V
AI-YC303
AI-900MF wall-mounting
bracket
Interface cards
AI-900MS Master Station Interface Card
One or two cards per Main Frame. The AI-900MS card provides
connection and audio recording outputs for one or two master stations.
With two cards installed, four master stations can be connected to one
Main Frame.
AI-900DI Direct-Select/Master Station Interface Board
Used to create a direct-select style master station in place of a digital
master. Used with AI-910DI for individual selector buttons and call-in
LEDs. Also allows integration with external security systems via
AI-910DI board.
AI-900AL Telephone Master Station Card
One or two cards per Main Frame, used in lieu of AI-900MS card. The AI900AL allows a standard telephone with caller-ID capabilities to be used
in place of a master station for communication functions. One or two
phones per card, taking the place of an AI-900MS card supporting two
master stations. Equipped with audio recording outputs for each
telephone connected.
AI-910DI Direct-Select Input/Output Relay Board
The AI-910DI is used in conjunction with the AI-900DI board to provide
relay outputs to control external devices or systems. Each board contains
32 programmable relays, and multiple boards can be used for up to 1024
relays. Use for integration with access control and/or video surveillance
systems.
AI-900RS, Substation Interface Card
Up to four cards per Main Frame. Each AI-900RS card supports up to 16
substations, and up to 64 substations per Main Frame with four cards
installed. Connect subs with simple two conductor shielded wire
homerun to the Main Frame.
AI-900CO C/O Telephone Line Interface Card
One card per Main Frame. The AI-900CO allows the connection of up to
two outside phone lines, with audio recording outputs for each line.
Integration with outside lines allows communication between sub or
master stations and standard telephones, cell phones, or pagers.
AI-900AF Audio Function Card
Connection of external PA amplifier for paging. Up to four inputs from
audio sources and 16 outputs to external paging zones. Multiple zones or
all zones can be selected and paged simultaneously.
AI-900TI Tie Line Interface Card
One card per Main Frame in multi-exchange system. The AI-900TI card is
used to interconnect multiple Main Frames, expanding the capacity and
functionality of the system. Up to four voice paths between Main Frames.
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
The AI-900MF Main Frame can accommodate
the following features with the installation of
the corresponding circuit cards. Up to 4 master
stations or single line phones (2 masters per
AI-900MS card; 2 phones per AI-900AL card);
up to 64 substations; up to 2 CO lines; paging
to 19 zones; tie line connection to additional
Main Frame, RS-232 input/output for system
programming and event logging.
Specifications (AI-900)
Power Source
Current consumption
Communication Modes
Serial Ports
Operating Temperature
System Capacity
Master Station Mounting
Master Station Wiring
Substation Mounting
Substation Wiring
Wiring Distance:
- Master to AI-900MS
- Subs to AI-900RS
- Between Main Frames
20V AC, 2.5A, provided by AI-PU200; 24V DC
provided by external 5A power supply not
supplied Aiphone
7A
Duplex, half-duplex, and Push-to-Talk
RS-232 compliant, D-sub connector ( 9-pin
female) 2 ports
-Indoor Units
0kC~40kC
-Outdoor Units -10kC~55kC
4 master stations; 64 substations per Main
Frame
Wall or desk mount
2 twisted pairs, homerun to Main Frame
Flush mount in 2-gang box
2 conductor shielded, homerun to Main Frame
900m(0.5mma). 1500m(0.65mma)
500m(0.5mma). 800m(0.65mma)
600m(0.5mma). 1000m(0.65mma)
82
Security Window Intercom System
SERVICE SIDE
1
PUBLIC SIDE
1 IMU-100
Service Side
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
IMU-100
Main kit
IMU-100
IME-100
OU-100
Operation unit
IME-100
Gooseneck microphone
MU-100
Main unit
Power supply PS-2420S
PS-2420UL
PS-2420 m P.107
Features
l First in industry! Using an acoustic tube with noise cancelling
microphone
l Voice-actuated hands-free communication
l Flexible gooseneck type microphone
l Optional Mono type headset (a3.5 plug)
l Detection sensor switches automatically to communication mode
l Separate speaker system using an optional microphone
l Paging feature for announcements
l Thin shape of the acoustic tube does not obstruct the field of vision
l Holes in the barrier glass are not necessary to install
Communication network
Acoustic tube system
3
Paging
speaker
ISE-100
2
Barrier
glass
IAI-100
+
IAX-100
1
IMU-100
+
IME-100
Service Side
1
2
3
Public Side
Voice-actuated hands-free communication
Automatically switch to communication mode
Paging
Separate speaker system
3
Paging
speaker
ISE-100
2
External
speaker
+
Barrier
glass
IME-150
3
IMU-100
+
IME-100
Service Side
83
Public Side
Lineup
Public Side
Acoustic tube system
Separate speaker system
Acoustic interface kit
ISE-100
External Speaker
(locally available)
IAI-100
IAX-100
DR-100
Driver unit
Sensor
+
Paging speaker
(locally available)
IAX-100
Acoustic tube
AI-100
Acoustic
I/O tube
IME-150
Optional microphone
Unit dimensions
Wiring
20m / (1.2mma)
IMU-100
Supplied
cable
+
Cord (3.5m)
IME-100
IME-150
160
27
ISE-100
Paging
speaker
130
40
210
49
Cord (3.5m)
Shielded
cable
2
370
2
Shielded
cable
External
speaker
+
24
388
2
2
2
206
Mic.
AI-100
OU-100
45
Speaker
MU-100
Separate speaker system
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
IAI-100
IME-100
63
420
14.5
510
2
34
3800
40
N
24
IAX-100
IME-150
Shielded
WHITE
RED
Shielded
WHITE
RED
–
SW
+
PG
OUT
C
H
DC24V
+
–
Connection cord (approx. 3.5m)
13
Specifications (IMU-100)
Power source
Consumption
Operating temperature
Communication
Headset
External speaker
Paging speaker
N : PS-2420S, PS-2420UL
150
68
W3
N
36
72
3500
Shielded(E)
WHITE(-)
RED(+)
Connection cord
(approx. 3.5m)
ST-BY
SW
23
60
WHITE(C)
BLACK(H)
DR-100
30
W1
E
–
+
ISE-100
3500
105
C
H
115
W2
Separate speaker system
27
84
Supplied cable
(approx. 2m)
Connector
1000
DC 24 V
120 mA (standby) 780 mA (maximum)
0kC to 40kC
Voice-actuated communication
Transmit output: 3 W 4 Ω, Receive output: 1.5 W 16 Ω
a3.5 plug, Impedance: 32 Ω, Rated input:
40 mW or more, Maximum input: 100 mW or more
Impedance: 4 to 8 Ω, Rated input: 3 W or more
Maximum input: 6 W or more
Impedance: 4 to 8 Ω, Rated input: 3 W or more
Maximum input: 6 W or more
84
Master / Sub Intercom
MASTER
SUB
120 NEM
1
Master station
Sub station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NB-L
Ceiling sub station
NEM-10/C
NEM-20/C
NEM-30/C
NEM-40/C
10-call master
20-call master
30-call master
40-call master
NA-NE
Sub station
NEM-10A/C NEM-20A/C
10-call master
NEM-30A/C NEM-40A/C
20-call master
40-call master
30-call master
NA-A
NA-AN
Sub station
Privacy sub station
Power supply
PS-2420S PS-2420UL PS-2420 m P.107
Features
Wiring
l Lamp memory intercom: Sub’s call-in with tone & light
l Press-to-talk or handset with voice actuation
l Selective or group call of 10 subs
l All Call
l Pre-tone sounding at sub, when selected
l Optional accessories for health care applications
l Expand beyond 40 stations with add-on selectors
NEM-40A/C
1
2
3
4
10
EE
Communication network
NA-A
NEM-40A/C
NA-A
NA-NE
NA-A
NA-A
NA-NE
1.
2.
3.
NA-A
NA-A
2
2
NA-NE
2
40
E
IER-2
NEM-40A/C
2xn
2.
NA-A
2
NA-A
2
NA-NE
2
NEM-40A/C
2 x n1
3.
NA-A
NA-A
2
2
1
E
S
S
PS24
+
-
85
2 x n2
2
2
NA-A
NA-A
NA-AN
NA-AN
NA-AN
RD
OG
OG/WH
BL
GR
BK
2
NA-NE
1. Run a parallel cable to each NA sub station (in the same conduit).
2. Run a multi-conductor cable(s) throughout system.
3. Run multi-conductor cables up to junction box, then run a parallel cable to
each NA sub station.
Homerun
1
2
3
4
NE-JA
NA-NE
2
N : PS-2420S, PS-2420UL
NEM-60A
A
B
C
D
E
31
32
33
34
Wiring
1.
A
B
C
D
E
NA-NE
1. Selective individual call 2. Selective group call (max. 10) 3. All call
2xn
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
NA-AN
NA-AN
RD
OG
OG/WH
BL
GR
BK
NA-NE
RD: Red OG: Orange OG/WH: Orange/White BL: Blue GR: Green BK: Black
IMPORTANT: For NE-JA sub(‘s), homerun wires to secure stable calling and
distance of 270m w/1.0mma.
Lineup
NB-U
Call button
Music adaptor
m P.102
NE-JA
Flush sub station
NBR-7AS
Bathroom pullcord,
moisture-resistant
NA-T/A(*1)
Handset sub station
NEM-50
NEM-50A
50-call master
50-call master
NEM-60
NEM-60A
60-call master
60-call master
NEM-70
NEM-70A
70-call master
70-call master
NBJ-20(*2)
NBJ-20B(*2)
NEM-80
NEM-80A
80-call master
80-call master
NEM-90
NEM-90A
90-call master
90-call master
NEM-100
NEM-100A
Call switching
device
for NEM-10/C,
20/C
m P.102
Call switching
device
for NEM-10A/C,
20A/C
m P.102
100-call master
100-call master
NBJ-40(*2)
NBJ-40B(*2)
NEM-110
NEM-110A
110-call master
110-call master
NEM-120
NEM-120A
120-call master
120-call master
Call switching
device
for NEM-30/C,
40/C
m P.102
Call switching
device
for NEM-30A/C,
40A/C
m P.102
(*1 ) NA-T/A: Not available in Europe, Australia, nor New Zealand
NEW-5
IER-2
Dual master
call adaptor
m P.103
Call extension
m P.104
(*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe
Unit dimensions
NEM-20/C
NEM-40/C
N
+
–
N
+
–
346
446
596
496
NA-A, AN
NA-NE
NEM-120
NEM-80A
• NA-NE
142
NA-NE
NA-A
NA-AN
NAR-6A
A
B
C
D
E
RD
OG
115
No.
NAR-6A
NA-T/A
NE-JA
OG/WH
BLx2
BL
GR
BK
83.5
No.
116
10
(2-gang)
94
• NB-L
NB-L
No.
E
RD
BK
NAR-6A
GR
105
Specifications (NEM-40A/C)
Power source
Power supply
Communication
BL
OG
OG/WH
BLx2
1. Power supply requirements
One power supply for up to 40-call master
Two power supplies for 50- to 80-call master
Three power supplies for 80- to 120-call master
2. Adding call button to NA sub stations
RD: Red BK: Black GR: Green BL: Blue OG: Orange
OG/WH: Orange/White
N : PS2420S, PS-2420UL
74
68
160
E
E
BLx2
185
220
2.
• NA-A, NA-AN
176
140
169
N
N
NEM-20A/C
NEM-40A/C
232
N
1+
1–
2+
2–
1+
1–
140
260
1.
260
Wiring
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NAR-6A
Output
Wiring
Distance
24V DC, 45W max. 2.5W standby (NEM-40/C)
PS-2420S, PS-2420UL (40-call)
Sub calls in w/tone & LED latching at master. Press
TALK button to transmit, release to listen, or lift
handset. At sub, pretone and voice when selected.
Talk hands-free.
Press ALL CALL button to activate all sub stations.
500mW max., adjustable.
All Call: 6W, 12W.
Selectively up to 10 subs w/TALK: 3W
2 wires per sub, non-twisted (1 common + no. Subs)
NEM to NA subs 130m(0.65mma) 200m(0.8mma)
86
Master / Sub Intercom
MASTER
SUB
100 TC-M
2
Master station
Add-on selector
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
IER-2
Call extension
m P.104
TC-10M
TC-20G
10-call master
20-call add-on selector
TAR-3
TB-SE
External signaling
relay
m P.105
Sub station
Power supply
PS-1820S
PS-1820UL
PS-1820
TC-40G
40-call add-on selector
TC-20M
TC-40GS
20-call master
W/add’l 20-/40-call expansion
Features
m P.107
Wiring
l Expandable internal telephone intercom
l One or dual master configuration
l Tone & LED call-in, staying on until answered
l Additional buzzer at TB-SE (w/relay)
l TRANSFER button on TC-M for communication between two
TB-SE subs
900m / 1.0mma
TB-SE
TC-M
2
TB-SE
Communication network
TB-SE
TC-20M
TB-SE
*TB-SE
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
E
E
3
E
TB-SE
480
405
330
255
4
E
E
E
E
5
5
6
6
7
7
E
E
E
M
C
E
M
C
E
+
12V
T
S
R S
83.5
210
230
210
72
S
TC-20G
TC-40G
The TC-40GS is equipped with socket to connect the second add-on selector
TC-20G or TC-40G.
10
+
12V T
S R
TB-AD1
1
E
IER-2
Specifications (TC-M)
Consumption
Power supply
Communication
TC-40GS
E
l Run 2 parallel wires per TB-SE. Use any E terminal for max. three TB-SE’s.
l Do not parallel TB-SE sub wires, or door station wires (in dual-TC-M system).
Power source
Wiring
8
E
E
9.TB-SE
IER-2
E
1 TB-SE
2
1
2
1
2
1
2
1
2
1
2
1
2
9
1
2
1
E
80
3
E
E
115
555
630
1
E
E
10
TB-AD1
TB-SE
2
2
4
E
Unit dimensions
E
U
U
2
9
*TB-SE : Sub station for two-master call.
TC-10M
TC-20M
TC-M
3
TB-SE
2
2
8
TC-20M
87
Lineup
Sub station
Wiring
Distance
18V DC, 350mA.
15~16V AC, 50/60Hz, 750mA.
6W. 3W standby.
PS-1820S, PS-1820UL, AC transformer.
Pick up TB-SE handset. Rings TC-M, w/tremolo & LED,
staying. At TC-M, pick up and press a lit selector to
reply.
2 parallel wires per TB-SE, non-polarized.
TC-M’s 200m(0.65mma) 480m(1.0mma)
TC-M~TB-SE 400m(0.65mma) 900m(1.0mma)
Master / Sub Intercom
DOOR
ROOM
1 TC-M & TB-AD10
10
Door station
Master station
Door adaptor
Lineup
Call extension
m P.104
TB-AD1
IF-DA
1-call door adaptor
Door station
m P.34
TC-10M
10-call master
TC-10MD
TB-AD10
10-call master
for door release
*Not available in Europe
TAR-3
10-call door adaptor
External signaling
relay
m P.105
Power supply
PS-1820S PS-1820UL PS-1820
TB-ADD
10-way door release adaptor
*Not available in Europe
m P.107
Features
Wiring
l Single or multiple audio door communication, expandable
l Optional selective door release control
IF-DA
TB-AD10
TC-10MD
TB-ADD Electric door strike
2
2 (x10)
Communication network
NP
PT
11
IF-DA
TC-M+TB-AD10
1.
2.
1
2
D1
1
2
D2
1
2
D3
1
2
D4
1
2
D10
TB-ADD
10.
Electric door strike
( 10)
M
Pre-tone sounding or mute selectable at TB-AD10.
1
2
3
4
1
2
3
4
D1
D2
D3
D4
D1
D2
D3
D4
10
10
D10
DE
D10
DE
12V
12V
T
R
T
R
E
E
E
TB-AD1
TB-AD10
E
PRE-TONE
ON OFF
TB-AD10
2
TB-AD10
3
74
42
150
2
T
TC-20M
TB-AD1
L3
L3
Electric door strike
TC-20M + TC-20G
TB-AD10
1
97
Wiring
IF-DA
L2
L2
L10
L10
U
230
83.5
140
IF-DA
L1
L1
L4
L4
E
Unit dimensions
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
IER-2
2
10
5
2
2
10
IF-DA
10
Multiple TB-AD10 installation; Add a power supply for TB-AD10 #3 or after.
1
2
1
2
N
+
–
T
R
2
U : PS-1820S, PS-1820UL
Specifications (TB-AD10)
U
TB-AD1 5 (x3)
TB-AD1
TB-AD1
2
19
20
+
–
T
R
2
Wiring
TC-20M
IF-DA
IF-DA
Power source
Door capacity
Communication
IF-DA
Distance
TB-AD10: 12V DC, supplied by TC-M.
10(TB-AD10). 1(TB-AD1).
Door calls in w/tremolo & LED 40 sec. Pick up and
depress LED lit selector. Pretone sounds at door, or
silenced.
2 parallel wires to door, non-polarized.
4 common + no. doors, TC-M to adaptor.
TC-M to TB-AD10 65m(0.65mma) 150m(1.0mma)
TB-AD10 to IF-DA 150m(0.65mma) 360m(1.0mma)
88
Master / Sub Intercom
DOOR
Scheduled to stop production
ROOM
1 TC-M & TB-ADM10
10
Door station
Master station
Door adaptor
Lineup
Video monitor
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
MYW-BA
Long distance
adaptor
m P.26
TC-10M
MK-DBC
10-call master
Video door station
TC-10MD
TB-ADM10
10-call master
for door release
10-call PanTilt adaptor
MYH-CU
IER-2
Video-monitor
Power supply
PS-1820S PS-1820UL PS-1820
Call extension
m P.104
TAR-3
External signaling
relay
m P.105
TB-ADD
10-way door release adaptor
m P.107
Features
Wiring
l Max. 10 PanTilt video door communication
l Optional selective door release control
l Manual or auto video monitoring
MYH-CU
MK-DBC
2 (x10)
6 TB-ADM10
TC-10MD
TB-ADD
NP
Communication network
A1
A2
1A1
1A2
A1
A2
2A1
2A2
A1
A2
3A1
3A2
A1
A2
4A1
4A2
A1
A2
10A1
10A2
1.
MK-DBC
MYH-CU
2.
10.
MYH-CU
Electric door strike
( 10)
TB-ADD
1A1
1A2
U1
U2
U1
U2
D1
D2
D3
D4
D1
D2
D3
D4
10
E
D10
DE
D10
DE
L1
L1
L2
L2
L3
L3
L4
L4
CN7A
CN2
L10
L10
Electric door strike
PS18
CN9
CN9
COAX
OPTION
b
b
PS18
M
PRE-TONE
ON OFF
Time lapse
VCR control
l Each TC-M & TC-G has 2 sockets for plug-in connectors from TB-ADM10 with
supplied junction cables. On TC-M, PanTilt selector # terminals must remain vacant.
U : PS-1820S, PS-1820UL
PanTilt viewing
Unit dimensions
Specifications (TB-ADM10)
92
MYH-CU : 2-gang mounting
210
83.5
MYH-CU
230
TB-ADM10
195
1A1
1A2
1
2
3
4
Electric door strike
2
PT
11
CN1
CN11
TC-10M &
TB-ADM10
89
*Not available in Europe
155
50
Power source
18V DC, 700mA.
Power supply
PS-1820S, PS-1820UL
PanTilt door capacity10(incl. IE/IF audio).
Call-in
40 sec. timed.
MYH-CU image timer 2-1/2 min. timed.
Auto-scan timer
60 min. max. w/duration 10, 20 or 30 sec. Press
MONITOR 2 sec. to initiate.
Wiring
2 parallel wires to door, non-polarized
Distance
TB-ADM10 to door 50m(0.65mma) 100m(1.0mma)
TB-ADM10 to PS 5m(0.65mma) 10m(1.0mma)
Market-Com
STATION
60 MC-60/4A
Market-com station
*Not available in Europe
Market-com adaptor
Lineup
Paging speaker
MC-A/A
Zone page adaptor
MC-60/4B
Market-Com desk station
*Not available in Australia nor New Zealand
Power supply
PS-2420S PS-2420UL
PS-2420 m P.107
MC-60/4A
Market-Com station
Features
Wiring
l Max. 60-station paging & communication system
l Selective 4 talk channels with in-use LED’s
l Conference call among 3 stations
l Music cutout during paging
l Reinforced modular coil cord
MC-60/4A
10
3
7
2
7
S
1
7
7
1
7
2
7
3
7
MC-60/4A
10
7
#1
#2
MC
Communication network
7
7
7
7
7
7
7
7
#3
#4
MC-A/A
A
G
M
(1)
MC-60/4A
MC-60/4A
(2)
Ch.1
Ch.4
(1) Paging (2) Select a channel 1~4 paged, and communicate.
Unit dimensions
MC-60/4A
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
w/built-in transformer
(locally available)
#1- 10
3
2
1
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1/+
2
3
4
5/–
6
7
N
MC-A/A
1
2
3
10 -#2
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
#3~#6
143
83.5
234
Station blocks #1~6 of max. ten MC-60/4A’s
N : PS-2420S, PS-2420UL
Specifications (MC-60/4A)
91
90
51.5
94
Specifications (MC-A/A)
Power source
Amp. input
Music soursce output
24V DC, PS-2420S, PS-2420UL
AUX 10Kd, 0.3V~0.5V
Range 100mV~1.2V, 10Kd or less
Power source
Power supply
Communication
Talk channel
Wiring
Cable specified
Distance
24V DC, 70mA max. (in page).
PS-2420S, PS-2420UL at MC-A/A.
Pick up and depress channel selector 1~4 and page
w/PAGE button. Called party picks up and presses lit
LED channel button.
4 and a separate paging channel.
7 wires in loop, non-twisted.
Line capacitance less than 25pF/30cm.
MC-A/A to MC-60/4A(*) 500m(0.65mma)
750m(0.8mma)
Total wiring distance 1500m(0.65mma, 0.8mma)
(*) MC-A/A to farthest MC-60/4A, or between two farthest MC-60/4A’s of
different blocks.
90
Mid-Power Intercom
MASTER
SUB
3 MP-S
1
Master station
Sub station
Lineup
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
N-EA*
NBZ-M*
Surface round
frame
Flush square
frame
NP-W*
Surface mount
box
for NP-B
AS-3N
Sub station
MP-1S
MP-3S
1-call master
3-call master
8d horn speaker
locally available
Call button
Power supply
PS-1225S
PS-1225UL
PS-1225
AS-3A
NP-B
Sub station
Flush call plate
m P.106
*Not available in Europe
Features
Wiring
l 1 or 3-call mid-power intercom, 2.5W powered
l Incorporates subs either in console, ceiling mount or 8d horn for
maximum output
l Hands-free reply from sub
MP-1S
150m / 0.8mma
2
MP-1S
8ohm
2
NP-B
1
E
T
Communication network
8ohm
BL
+
-
RD
MP-3S
MP-1S
MP-1S
MP-3S
8Ω
2x3
AS-3A
2
AS-3N
2
2
8ohm
NP-B
1
E
MP-3S
AS-3A
2
E
AS-3N
NP
NP
1
E
NP-B
BL
★
8Ω
MP-3S
NP-B
3
E
NP-B
T
NP
+
-
BL
8ohm
RD
8d Horn w/talkback reply
l For 8d horn without NP-B, install a 33MFD, 25V NP capacitor on No. line.
BL : Blue(2) RD : Red(2) ★NP-25V Capacitor T : PS-1225S, PS-1225UL
Unit dimensions
MP-1S
MP-3S
43
78
91
83.5
169
83.5
Power source
Power supply
Communication
177
148
Specifications (MP-S)
AS-3A
142
41
Output
Output impedance
Wiring
74
Distance
12V DC, 1A.
PS-1225S, PS-1225UL
Sub calls in w/tone (& LED 20 sec. on MP-3S). Press
sub selector and TALK to transmit, and release to
listen.
2.5W at 1KHz.
8d
2 parallel wires per sub, non-polarized.
*Do not make E wires common.
MP-S to sub 100m(0.65mma) 150m(0.8mma)
High-Power Intercom
MASTER
SUB
10 AP-M
2
Master station
Sub station
Call button
Lineup
NP-W*
NP-B
Flush call plate
AS-3N
Sub station
NBZ-M*
Flush square
frame
for AS-3N
AP-5M
5-call master
AP-10M
10-call master
(Photo)
N-EA*
Surface round
frame
for AS-3N
AS-3A
AP-1M
Sub station
1-call master
*Not available in Europe
Features
Wiring
l 10 watt-powered paging & communication system
l Selective all call to 5 subs
l Single or dual-master configuration
l 8d or 16d horn speaker with talkback
2
2
NP-B
2
AS-3N
Communication network
7
(1)
AP-10M
(1)
AP-10M
1
E
NP-B
AS-3N
3
E
4
E
4
E
5
E
5
E
C
E
10
E
10
E
R
C
E
R
GND
GND
(1) 8d horn
Unit dimensions
140
BL RD
BL
1
E
RD
240
253
AP-5M, AP-10M
1
E
3
E
NP-B
NP25V
33µF
AP-10M
2
E
AS-3A
140
P.
2
E
NP-B
AP-1M
3P(2P+1)
AP-10M
AS-3A
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Surface mount
box
for NP-B
BL : Blue(2). RD : Red(2).
276
196
41
74
NP-B
180
169
142
Power source
Consumption
Communication
115
AS-3N
83.5
AS-3A
Specifications (AP-M)
15
47.5
70
16
27
Wiring
Distance
110~125V, 127V, 230V, 220~240V AC, 50/60Hz.
45W. 6W standby.
Sub calls in with tone & LED, 15 sec.
Depress selector and use Talk/Listen switch. All call
selectively to max. 5 subs. Max. 10W transmit,
adjustable.
300mW receive, adjustable.
1 twisted pair per sub, non-polarized
3 pairs (5), masters.
AP-M to sub 150m(0.65mma) 230m(0.8mma)
92
Nurse Call
MASTER
SUB
80 NHX
1
Master station
Add-on selector
Central control unit
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NHR-SP
Duty station
NHX-80X
Central control unit
NHX-50M
50-call master station
NHX-30G
Zone light
30-call add-on selector
Plugs into NHX-50M
NHR-30K
30-call add-on trunk card
NHR-3A-4
Power supply
PS-2420S PS-2420UL PS-2420 m P.107
Features
l One master, up to 80 sub stations. Single and dual patient stations
l Multi-station capability per patient room
l Three types of call-ins from patient stations: Routine call, Bathroom
call & Cord-out trouble call, identified by tone & blinking LED
(w/priority according to urgency and time of call)
l NHR-3TS Common Area Call station is used for common area
bathroom call or staff call (urgent)
l Optional zone light (max. 4)
4-zone call light
Communication network
NHR-4A/A
Duty station
NHR-SP
NH-2SA/A
NHR-7A
Tone &
LED
Communication
1. At NHX-50M master, when called by a bedside sub, either lift
handset or press TALK once to establish talk channel. To initiate
a call, press the selector button of the sub. At the sub, pretone
sounds and TALK is lit green. Corridor and zone lights do not
turn on.
To silence the tone, press TONE-OFF button. Tone will resume
after 90 seconds or when new call is placed.
2. Corridor lamp & Zone 1~4 light turn on with any type of call
placed by sub station area. When talk channel is established,
two lights will turn off.
3. A call from NHR-3TS is of the same level as Urgent bathroom
call. (no verbal communication)
Patient rooms
NH-1SA/A
Blinking
NHR-4A/A
• Routine call, Urgent bathroom call
or Cord-out trouble call
Tone &
LED
NHR-4A/A
NH-2SA/A
NHR-7A
Common area restrooms
NHR-7A
NHX-50M
NHX-30G
(up to 3)
NHR-3TS
(max. 4)
1
2
NHR-3A-4
Lights on for
any call
NHR-7A
3
4
• Urgent bathroom
call
NHR-3TS
• Urgent staff call
93
Duty station
Staff call area
NHR-7A
(up to 3)
*Not available in Europe, Australia, nor New Zealand
Sub station
Corridor lamp
NH-2SA/A
NHR-3TS
NHR-4A/A
Single-jack bedside sub station
Dual-jack bedside sub station
Calling zone light
Corridor lamp w/red &
white lamps
NHR-8A
NHR-DP
NHR-7A
NHR-7A
Bedside call switch
Dummy plug
Staff call switch
Bathroom pullcord
Call tone & light annunciation
TYPE OF CALL
Wiring
TONE
LIGHT
Single chime,
every 6 sec.
—
Blinking, every
2 sec.
‘CALL’ steadily lit
White lamp
steadily lit
Routine call
At NHX-50M (& at Duty station)
At Bedside sub
At Corridor lamp
—
NHR-4A/A
Sub trunk line
(max. 10 subs)
NH-1SA/A
3P
NHR-4A/A
NH-2SA/A
NHR-7A
3
NHR-4A/A
Single chime,
every 2 sec.
At Bedside sub
—
At Corridor lamp
—
Double blinking,
every 1.8 sec.
‘CALL’ steadily lit
& on pullcord
Red lamp
steadily lit
NHR-7A
20m NH-1SA/A
3
3
3P
NHR-7A
3
Cord-out trouble call
NHR-7A
3
3
Single chime,
every 0.5 sec.
At Bedside sub
—
At Corridor lamp
—
Blinking fast,
every 0.4 sec.
‘CALL’ steadily lit
& on pullcord
White lamp
steadily lit
3
2
NHR-7A
3
3P
3P
1
5
1
2
1
3
4
5
PS
2
1
3
4
NHR-3TS in common area
Staff call (urgent)
—
Red blinking
(2 lamps)
White blinking
(one lamp)
5m PS
PS
2
1
3
5
PS
5
4
2
5
50m
3
4
(max.4)
20m
5P
—
20m
......
NHX-80X
CCU
Bathroom call (urgent)
20m
NHR-7A
3
20m
NHR-3TS
3P
At NHX-50M (& at Duty station)
50m up to
farthest sub.
Max. 100m
per block.
3P
Urgent bathroom call or
NHR-3TS
NH-1SA/A
3
3
At NHX-50M (& at Duty station)
NH-1SA/A
3
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NH-1SA/A
20m
NHR-SP
NHX-50M/NHX-30G
PS : PS-2420S,UL
Line-off trouble at NHX-50M
Line-off at bedside sub
Line-off at Duty station
Slow buzzer,
intermittent
Faster buzzer,
intermittent
Lit 0.2 sec.,
every 2 sec.
No light
Sub trunk line: 6 wires (3P). 4P with NHR-3A-4 light included.
Each zone requires a separate common wire from NHX-80X.
Use twisted pairs with an overall shield, low capacitance, 0.65mm dia.,
solid conductors. (Rated capacitance level of wire: 25pF/30cm or less)
94
Nurse Call
NHX Components
Central control unit
Central control unit
Specifications (NHX-80X)
Controls the NHX-50M
and up to 80 sub
stations. 1 ~ 8 trunk lines
of up to 10 stations per
trunk connected inside
CCU. (3 pairs, or 4 pairs
if zone light is installed).
5 pairs to Master station.
Terminates in CCU Zone
light (4 in loop), Duty
station, and power
supplies(2).
After installation, the
NHX-80X must be
initialized. During use,
turn power switch off and
back on to reset.
Install NHR-30K
Expansion Trunk Card
when NHX-30G is used.
Power Source
Power supply
Station capacity
Calling
Communication
Call-in priority
Warning tones
Wiring
Unit dimensions
NHX-80X
Wiring distance
460
NHR-30K
30-call add-on trunk card
Mounting
340
98
24V DC, 4A max.
2 pcs PS-2420S, UL power supplies
50 sub stations (max. 80 with NHX-30G & NHR-30K).
Routine call, Urgent bathroom call & Cord-out trouble call.
Up to 5 calls can be displayed on NHX-50M.
Single and private talk channel. Press-to-talk or handset
voice-actuation
(1) Cord-out trouble call, (2) Urgent bathroom call and
NHR-3TS common area bathroom call or staff call, (3)
Routine call. Subs’ call-ins on standby connected according
to urgency level and time of call.
(1) Line-off trouble at Bedside or NHR-3TS sub & Duty
station. (To stop tone on the Duty station, plug in, 2-pin
jumper to CN104 in CCU).(2) 90 sec. elapse timer: Call tone
goes up to HIGH level.(3) 90 sec. off-hook timer: Steady
tone will notify that handset is off-hook.
3 (or 4*) twisted pairs, CCU to Sub trunks 1~8. (*when
zone light is installed)
5 twisted pairs, CCU to NHX-50M.
6 wires (parallel), CCU to NHR-SP.
5 wires (parallel), CCU to NHR-3A-4.
Use twisted pairs with an overall shield, low capacitance,
0.65mm dia., solid conductors. (Rated capacitance level
of wire: 25pF/30cm or less)
CCU to Sub (farthest) 50m(0.65mm)
Sub trunk line 100m(0.65mm)
CCU to NHX-50M 20m(0.65mm)
CCU to Duty station 20m(0.65mm)
CCU to Zone light 50m(1.0mm)
CCU to PS-2420UL 5m(1.0mm)
3-gang wall-mounting. Or inside Electrical Enclosure with
secured door (Provide a suitable, non-combustible
mounting surface).
Master station
Features
NHX-50M
50-call master station
Unit dimensions
NHX-50M
NHX-30G
210
Extremely compact 50-call desk console.
Open voice communication with TALK
button, or handset (voice-actuated). When
called, simply press TALK or pick up handset
to establish channel. Otherwise, press TONEOFF button and go to calling location. To
initiate a call, press a selector button first.
NHX-30G is a 30-call add-on selector. Plugs
itno NHX-50M.
210
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NHX-80X
Features
280
94
90
58.5
Specifications (NHX-80X)
Wiring
NHX-30G
30-call add-on selector
Distance
10-pin plug in connector (to NHX80X). Provided with preset volume
controls. Can verify connection of all
sub stations.
Install within 20m from CCU.
Duty station
Features
Specifications (NHX-80X)
Acknowledges any station call with tone and
blinking LED. Go to the NHX-50M. Press
TONE-OFF and identify the caller at Master
station.
Mounting
Wiring
Unit dimensions
120
NHR-SP
NHR-SP
Duty station
116
95
46
2-gang semi-flush mounting.
CN1 (6 pin) to NHX-80X. When NHRSP is installed, unplug Connector
from CN104 on NHX-80X.
Bedside sub station
NH-2SA/A
Single-jack bedside
sub station
Dual-jack bedside
sub station
Specifications
Bedside station for calling and
communication. Used with NHR-8A call
cord. When call button is pushed, iCALLj
LED is lit red. When master replies, green
iTALKj LED is lit. Press CANCEL to reset
the call. When NHX-50M calls in, pre-tone
sounds and iTALKj LED is lit green.
Dummy plug (NHR-DP)
Plugs into jack unused on bedside sub
stations.
Mounting
Wiring
2-gang semi-flush mounting
Sub Nos. 1 ~ 10 setting on
SW1.
CN1 (6 pin) to sub trunk
line.
CN2 (8 pin) for NHR-7A,
NHR-4A/A & zone light.
Unit dimensions
120
NHR-8A
NHR-3TS
NHR-3TS
120
NH-1SA/A, NH-2SA/A
Bedside call switch
Calling zone light
116
46
116
28 45
NHR-DP
Dummy plug
Bathroom pullcord
NHR-7A
Staff call switch
Mechanically locked calling device, used to
place an urgent bathroom call from a patient
room, common area bathroom or staff call
location. Cannot be used alone, and must be
used with NH-1SA/A, NH-2SA/A, or with
NHR-3TS common area call station.
Provides dry closure contact. Master-CALL
LED indicates call placed.
Ratings DV 24V, 100mA (min. 5mA or
more).
Unit dimensions
NHR-7A
115
Features
71
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NH-1SA/A
Features
10
Specifications
Wiring
Distance
Single-gang semi-flush mounting.
3 wires to patient station or NHR-3TS.
Corridor lamp
When a call is placed, the NHR-4A blinks red
or is steadily lit white.
Ratings: DC 24V (or more), 200mA max.
Unit dimensions
NHR-4A /A
120
Features
70
NHR-4A/A
27
Specifications
Corridor lamp w/red &
white lamps
Wiring
Distance
Single-gang semi-flush mounting.
3 wires to Bedside sub station.
Zone light
NHR-3A-4
4-zone call light
Unit dimensions
NHR-3A-4
46
Zone lamp turns on when any call is placed
on the system, indicating which zone has a
call placed. Up to 4 zone lights can be
installed in one system. Install one
PS-2420S, UL for every 2 zone lights.
Lamp ratings: DC 24V ~, 200mA.
120
Features
438
96
Nurse Call
NHX-80X
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
51
52
53
54
55
56
A
NH-1SA/A
NH-1SA/A
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
ZL
ZL
ZL
11
12
13
14
15
16
Z3
Z1
61
62
63
64
65
66
21
22
23
24
25
26
71
72
73
74
75
76
31
32
33
34
35
36
Z4
81
82
83
84
85
86
NH-1SA/A
D
1
2
NHR-3A-4
1
3
2
3
4
OR
YL
RD
GR
BL
RD
4
NHR-3A-4
NHR-3A-4
1
1
2
3
2
+
---
+
---
G
G
PS-2420S
WL
WL
RL
E
RL
E
TC
TL
E
TC
TL
E
2 NHR-4A/A
RD
OG
R1
R2
ZL
LC
R3
R4
RC
E
PR
GY
ZL
LC
NHR-7A
YL
BL
GR
BL
PS-2420S
NHX-50M
DS1
DS2
DS3
DS4
DS5
DS6
A Patient rooms w/a single bedside sub station
B Staff call (corridor)
C Bathroom call (common area)
D Patinent rooms w/multiple bedside sub stations
E Corridor lamp NHR-4A/A
1 : Two white lamps 2 : One red lamp
NHR-4A 2 is required only when NHR-7A bathroom
pullcord is installed in a single and common bathroom.
97
1
2
3
4
5
6
BR
OG
RD
OG
6 (parallel)
NHR-SP
1
2
3
4
5
6
41
42
43
44
45
46
4
OR
YL
RD
GR
BL
RD
OR
YL
RD
GR
BL
RD
OR
YL
RD
GR
BL
RD
3
4
NH-1SA/A
Z2
1 NHR-4A/A
NHR-3A-4
NH-1SA/A
S1
S2
S3
S4
S5
S6
PS24
A+
A-
PS24
B+
B-
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
NHX-30G
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
PS24: PS-2420S, PS-2420UL, PS-2420
Wire color identifications
NHR-3A-4
OR: Orange (Zone 1)
YL: Yellow (Zone 2)
RD: Red (+)
GR: Green (Zone 3)
BL: Blue (Zone 4)
RD: Red (+)
Zone light relay makes
contact.
NHR-4A/A
BR: Brown
OG: Orange
RD: Red
OG: Orange
NHR-7A
YL: Yellow
BL: Blue
GR: Green
BL: Blue
NH-1SA/A
BR: Brown
RD: Red
OG: Orange
YL: Yellow
GR: Green
BL: Blue
PR: Purple
GY: Gray
NHR-3TS
BR: Brown
RD: Red
OG: Orange
YL: Yellow
GR: Green
BL: Blue
PR: Purple
B
NH-1SA/A
C
NHR-3TS
NHR-3TS
NHR-7A
WL
RL
E
TC
TL
E
ZL
PR
GY
1
2
3
4
5
6
BR
RD
OG
YL
GR
BL
PR
BR
OG
RD
OG
YL
BL
GR
BL
NHR-4A/A
1
2
3
4
5
6
WH
TC1
TL1
BR
RD
RD
E
OG
TC2
TL2
YL
GR
BL
NHR-7A
YL
BL
GR
BL
NHR-7A
ZL
TC1
TL1
BR
RD
E
OG
TC2
TL2
ZL
NH-1SA/A
NH-1SA/A
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
WL
WL
WL
WL
RL
E
RL
E
RL
E
RL
E
TC
TL
E
TC
TL
E
TC
TL
E
TC
TL
E
ZL
LC
PR
GY
ZL
LC
PR
GY
YL
BL
GR
BL
BL
PR
NH-1SA/A
PR
GY
YL
BL
GR
BL
YL
GR
NH-1SA/A
ZL
LC
NHR-7A
YL
BL
GR
BL
YL
BL
GR
BL
ZL
LC
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1
2
3
4
5
6
Multi-station patient room applications
Multiple NH-1SA/A and NH-2SA/A bedside sub stations can be installed within a patient room,
observing the following conditions;
1. Max. 6 bedside sub stations may be connected per room for max. 12 calls (when NH-2SA/A
stations are used).
2. A corridor lamp inside (NHR-4A) must not be connected with more than 4 bedside sub stations.
3. Due to the above, install two NHR-4A/A corridor lamps when more than 4 sub stations are in one
room, i.e. two WHITE lamps used in one NHR-4A/A, and one RED bulb used in the other NHR-4A/A.
4. NH-1SA/A and NH-2SA/A station numbers must be programmed in numerical order and connected
to the same subs trunk line.
5. NHR-7A bathroom pullcord is optional.
98
Nurse Call
MASTER
SUB
120 NEM
1
Master station
Sub station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NEM-10/C
NEM-10A/C
10-call master
10-call master
NEM-20/C
NEM-20A/C
20-call master
20-call master
NA-A
Sub station
NA-AN
Privacy sub station
NEM-30/C
NEM-30A/C
30-call master
30-call master
NEM-40/C
NEM-40A/C
40-call master
40-call master
Features
Power supply
PS-2420S PS-2420UL
PS-2420 m P.107
Wiring
l Lamp memory intercom: Sub’s call-in with tone & light
l Press-to-talk or handset with voice actuation
l Selective or group call of 10 subs
l All Call
l Pre-tone sounding at sub, when selected
l Optional accessories for health care applications
l Expand beyond 40 stations with 50-120-call master stations
NA-A/AN
NA-NE
NA-A/AN
2
2
2
2
2
2
NB-L
1+n
1+n
2
NBY-1A
(1)
2
(2)
2
NBY-4A
NBY-4A
2
NEM-40A/C
(3)
(1)
(2)
(2)
NB-L
NA-A
NA-A
NA-A
NA-A
(3)
NBR-7AS-S
(4)
(5)
(1) All call for instant transmission to all subs
(2) Selective call up to 10 subs or individually
(3) Subs call-in w/tone & LED staying with corridor light on
(4) NBR-7AS-S: Bathroom pullcord in a patient room
(5) Multi-substation patient room
99
NAR-2A
l 1 + n = 1 common + no. of Subs
NEM-40A/C
NEM-40A/C
NBR-7AS
2
3
2
Communication network
NBR-8A
3
Lineup
NAR-6A
NBY-4A
NAR-3
Call switching
device
for NEM-10/C,
20/C
m P.102
Call button
Corridor call
light
Round corridor
light
NBJ-40(*2)
Call extension
m P.104
NB-L
NE-JA
Ceiling sub station
Flush sub
station
NR-4AS13(*1) B
Call switching
device
for NEM-30/C,
40/C
m P.102
NB-U
Music adaptor
m P.102
NBJ-20B(*2)
NA-NE
Sub station
NA-T/A(*1)
NEW-5
NAR-2A
NBY-1A
Metal jack for
bedside call
switch
Dual master call NBJ-40B(*2)
adapto
Call switching
m P.103
device
for NEM-30A/C,
40A/C
m P.102
Call reset button
NBR-8A
Bedside call
switch
Handset sub
station
NBR-7AS-S(*1)
NBR-7AS
Bathroom pullcord,
moisture-resistant
(*1 ) NA-T/A, NBR-7AS-S, NR-4AS13: Not available in Europe, Australia, nor New Zealand
Wiring
Call switching
device
for NEM-10A/C,
20A/C
m P.102
B
(*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe
Wiring
NEM-40A/C
NEM-40A/C
E
1
2
3
4
5
9
10
E
A
B
C
D
E
NBY-4A
1
2
3
4
5
6
7
8
9
10
NA-NE
NA-A
RD
BK
GR
OG
OG/WH
BL
NBY-4A
NBR-7AS-S
(SOP)
N
+
–
RD
BK
GR
BL
OG
(2)
NBY-1A
BL
BLx2
BLx2
E
RD
BK
GR
BL
OG
OG/WH
RD
BK
GR
BL
NBY-1A
NBY-4A
NBR-7AS
x2
BLx2
NBY-4A
NAR-2A
11
12
13
14
15
16
17
18
19
20
NBR-7AS
IER-2
S
S
X
NAR-2A
NB-L
39
40
1
E
RD
BK
GR
BL
OG
OG/WH
BL
NAR-2A
E
31
32
33
34
35
(1)
NB-L
NBY-4A
BLx2
NAR-2A
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NBJ-20(*2)
IER-2
NBR-8A
Health care application
l Up to three NBR-7ASs can be connected in parallel.
RD : Red BK : Black GR : Green OG : Orange OG/WH : Orange/White BL : Blue
N : PS-2420S, PS-2420UL
PS24
+
—
A
B
C
D
E
(3) BL
NR-4AS13
(SOP)
BL
BLx2
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
(4)
NA-A,
NA-AN
NAR-2A
Bathroom pullcord within a patient room
(1) NBR-7AS-S: Call-in from NBR-7AS-S cannot be cancelled with NAR-2A Call
reset button.
Press on upper end of Call button on NBR-7AS-S to release the call.
(2) Cut GREEN wire.
Multi-substation patient room
(3) NR-4AS13: NBY-4A corridor call light may hold up to three NA sub stations.
Use NR-4AS13 for more than three NA sub application.
(4) Remove the D - E link on each NA sub station.
N : PS-2420S, PS-2420UL
100
Nurse Call
Lineup
Call extension
m P.104
NEM-60A
60-call master
Unit dimensions
NEM-60A
60-call master
60-call master
NB-U
NEM-70
NEM-70A
70-call master
70-call master
Music adaptor
m P.102
NEM-80
NEM-80A
80-call master
80-call master
NEM-90
NEM-90A
90-call master
90-call master
NEM-100
NEM-100A
100-call master
100-call master
NEM-110
NEM-110A
110-call master
110-call master
NEM-120
NEM-120A
120-call master
120-call master
NEM-40A/C
260
746
896
1046
1196
15
47.5
NA-NE
142
340
74
83.5
82
Specifications (NEM)
Power source
70
NAR-6A
NAR-2A
55
Power supply
Communication
83.5
120
115
83.5
NBY-1A
70
43
NE-JA
23
3
10
(2-gang)
94
Output
Wiring
Distance
232
83.5
NA-T/A
115
95
*NEM-n/7.A width : Reduce 100mm (handset part) for each sized station.
120
185
220
NBY-4A
68
211
180
169
83.5
NA-A/AN
160
176
140
NEM-50A ~ NEM-120A
446
596
NB-L
101
50-call master
NEM-60
260
140
346
496
116
NEM-50A
50-call master
Unit dimensions
NEM-40/C
70
NEM-50
176
140
260
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
IER-2
105
24V DC, 45W max. 2.5W standby (40-call)
24V DC, 180W max. 7.5W standby (120-call)
PS-2420S, PS-2420UL (40-call)
Open voice press-to-talk or handset voice actuated.
Sub calls in w/tone & LED latching at master. Press
TALK button to transmit, release to listen, or lift
handset. At sub, pretone and voice when selected.
Talk hands-free.
Press ALL CALL button to activate all sub stations.
500mW max., adjustable.
All Call: 6W, 12W. 24W (120-call)
Selectively up to 10 subs w/TALK: 3W
2 wires per sub, non-twisted (1 common + no. Subs)
NEM to NA subs 130m(0.65mma) 200m(0.8mma)
Call switching device
Features
Call switching device
NBJ-40*
Call switching device
NBJ-20B*
Call switching device
Used for
NBJ-40B*
NBJ-20 for NEM-10/C &
NEM-20/C
NBJ-40 for NEM-30/C &
NEM-40/C
NBJ-20B for NEM-10A/C &
NEM-20A/C
NBJ-40B for NEM-30A/C &
NEM-40A/C
Call switching device
*Not available in Europe
NEM-20/C
NEM-20/C
1 2 3 4 ... n E
1 2 3 4 ... n E
1 2 3 4 ... n E
M1
1 2 3 4 ... n E
M2
S
1 2 3 4 ... n E M
NBJ-20
NBJ-20B
NA-A, AN, NE
NB-L
M1 : Master station 1. M2 : Master station 2. S : Sub station.
(*)Terminal M remains unused. (on NBJ-20B)
Music adaptor
Features
l Distributes music to all subs
with auto mute while
communicating.
l When NEM includes NEW-5
adaptor(s), NB-U cannot be
used.
Wiring
NA-A/AN/NE
NB-L
Used for
NEM-n/C, NEM-nA/C
(n = 10 ~ 40)
NEM-40A/C
1
2
3
4
5
6
7
8
9
10
40
E
NB-U
B
Y
B
Y
A1
V1
A1
V1
A2
V2
A2
V2
A3
V3
A3
V3
A4
V4
A4
V4
E
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
NBJ-20*
Wiring
l Switches all NA sub wiring
from one master to the other
to route all call-ins to the
master on duty.
l NBJ-20 & NBJ-20B are
equipped with a rotary
switch, and NBJ-40 &
NBJ-40B with two rotary
switches.
l When the rotary switch is put
to 1 position, all the sub
wiring is connected with
Master station(M1). To
switch the sub wiring to
Master station(M2), put the
rotary switch to 2 position.
E
BGM
8Ω
8Ω
NB-U
Music adaptor
l As shown, connect NB-U to 8 Ohm output of Amplifier with twisted pair wires.
l Remove jumpers between A1~V1, A2~V2,A3~V3, A4~V4 on master station.
l Amplifier requirements: Input: 100mV for rated output. 10W w/8d output or
10W w/4~16d output.
l Do not use 1Kd output on the amplifier.
Specifications
Power source
Permitted input
Wiring
Distance
6V DC, supplied by NEM.
5W. 10W at its peak.
3 wires commom + 2 per 10-call (max.11).
NB-U to NEM 10m(0.65mma) 15m(0.8mma)
NB-U to Amp. 75m(0.65mma) 115m(0.8mma)
102
Nurse Call
Dual-master call adaptor
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
103
l Common NA subs place a call
ringing two NEM masters.
l One NEW-5 req’d for every
five subs calling both
masters. Eight NEW-5 for 40
sub stations, can be powered
with one PS-1225S.
Used for
NEM-n/C, NEM-nA/C
(n=10~40)
Wiring
NA-A/AN/NE
NA-A
NEM-40A
2xNA
4+1xn
A
E
A
E
A
E
A
E
A
E
N
NEM-40A
4+1xn
2
40
3
4
4
5
+
-
5
NEW-5
36
37
38
39
40
E
H
Y
Q
MA1
MA2
MA3
MA4
MA5
MAE
MAH
MAY
MAQ
T : PS-1225S, PS-1225UL
36
37
38
39
40
E
H
Y
Q
MB1
MB2
MB3
MB4
MB5
MBE
MBH
MBY
MBQ
1S
1E
2S
2E
3S
3E
4S
4E
+ 5S
- 5E
A
E
A
E
A
E
A
E
A
E
NA-A
A
E
A
E
A
E
A
E
A
E
1
2
3
NA-A/AN/NE
2xNA
36
1
T
NEW-5
Dual master call adaptor
NEW-5
+
-
N
NA-A
N : PS-2420S, PS-2420UL
Specifications (NEW-5)
Power source
Power supply
Capacity
Communication
Wiring
Distance
12V DC
PS-1225S, PS-1225UL
5 subs per NEW-5.
Max. 8 adaptors for NEM-40(A)/C.
Separate channel for ea. master.
2 wires, NEW-5 to sub.
NEW-5 to sub 130m(0.65mma) 200m(0.8mma)
NEW-5 to NEM 100m(0.65mma) 150m(0.8mma)
Accessories
Call extension
Features
Wiring
l Announces (chime) call tone only, adjustable
l Indoor mounting
KC-1MRD
IER-2
Used for
2
IE series, MK-1GD, MK-2MCD
KC-1MRD, KC-1GRD, KB-3MRD
NEM-n, NEM-nA, TC-M
JB-2MD, JB-2MED, JA-2MECD, JA-2MCD
JF-1MD, JF-2MED
NP
S
S
Unit dimensions
1
E
IER-2
83.5
120
Call extension
29
88
Door release
Features
Wiring
l Door release activation,
momentary or talk linecontrolled
KC-1MRD
Used for
Electric door strike
(locally available)
RY-PA
Electric door
strike
Electric door
strike
L+
L–
YL
VC-M
–
L
L+
L–
BK
RY-PA
H
LEF-10C
H
BK : Black(2) YL : Yellow(2)
Specifications (RY-PA)
Power source
Relay contact rating
12V DC.
110V AC, 1A.
24V DC, 1A.
ACCESSORIES
Door release relay
Single-family unit
DA-1DS/G, C-123L/A
IE-1AD(U), IE-1GD(U)
IE-2AD(U), IE-8MD(2)
TD-H/B (via DE-UR)
LEM-1DL
LEF, LEF-C (via RY-PA)
MYW-P3CB(3)
MYW-P3L(3) (via RY-PA)
MK series
JA-2MECD, JA-2MCD
JB-2MD, JB-2MED
JF-1MD, JF-2MED
KC-1MRD, KC-1GRD
KB-3MRD
Multi-family unit
DA-2DS/G, DA-4DS/G
GF (5)
VC-M (via RY-PA)
Relay
Features
Wiring
Intercom station can be signaled by external
device via RY-AC/A relay. External device will
be activated momentarily as long as the call
signal on the intercom is activated.
Used for
TD-H/B, TD-Z/A
IE-Series
IE-8MD, LEF
LEF-10
LE-D
(1)
(2)
PWR
1
E
1
E
–
+
–
T
WH
YL
RD RY-A C/A
BK
YL
RY-AC/A
(1) External signaling device, bell, etc. (2) Call receive
termimal WH : White RD : Red(+) BK : Black(-) YL : Yellow
PWR : Power source
External signaling relay
Specifications (RY-AC/A)
Unit dimensions
62
Power source
104
41
Contact rating
12V DC, supplied by power supply of
system or trunk line.
0.3A, 240V AC. 1.0A, 24V DC.
Bell, buzzer, etc. must be AC
operated or DC mechanical type only.
104
Accessories
Relay
Features
Wiring
Allows integration of a
doorbell, etc. to intercom. The
device will be activated as long
as handset is ringing. When
the intercom is picked up, the
device will no longer be
activated.
MK-DH
(1)
NP
A1
A2
Used for
IE chime tone
IE-8MD
MK-1GD
MK-2MCD
KC, KB series
AT-406
TB-SE(TC-M)
TAR-3
MK-1GD
PWR
A1
A2
WH
BL
BK
S
S
A
+
–
U
TAR-3
(–)
(+)
OG
OG
RD
W
(1) Bell, etc. PWR : Power source
WH : White BL : Blue BK : Black(-) RD : Red(+) OG : Orange
W : PS-0602D, PS-0602C
Unit dimensions
62
External signaling relay
Specifications (TAR-3)
41
104
Power source
Contact rating
6V DC, supplied by PS-0602D, PS-0602C
0.3A, 240V AC.
1.0A, 24V DC.
Doorbell or buzzer must be AC operated
or DC mechanical type only.
Auxiliary light power control
Features
Wiring
ACCESSORIES
MAW-B relay is used for
turning on an auxiliary light to
spotlight a caller at the
entrance.
The light is illuminated when
the residential call button is
pressed, and during visual
monitoring mode.
KB-3MRD
(1)
(2)
MAW-B
WH
bn
E
BL
Used for
RD
KB-3MRD, GF-BC(GF)
OG
PWR
BK
N
+
–
bn = b1~b3
Unit dimensions
(1) Porch light, etc. (2) Local switch
WH : White BL : Blue RD : Red(+) BK : Black(-) OG : Orange(2)
MAW-B
Auxiliary light control relay
62
Specifications (MAW-B)
104
105
41
Power source
Power supply
Power consumption
Relay contact rating
24V DC.
PS-2420S, PS-2420UL of system.
2.5W max. 0.5W standby.
Dry closure contact for incandescent light for
general lighting of less than 100W.
Power Supplies
15V AC
Unit dimensions
PT-1211D
58
Specifications (PT-1211D)
46
Input voltage & Capacity
230V AC, 50/60Hz
Output voltage
15V AC
83
*Manufactured by Sino-American
PT-1211D
Specifications (PT-1211C)
48
77
PT-1211C
60
Input voltage & Capacity
120V AC, 50/60Hz
Output voltage
15V AC
*Manufactured by Sino-American
Used for
PT-1211C
DA-1MD
6V DC
Unit dimensions
Specifications (PS-0602C)
Input voltage & Capacity
120V AC, 50/60Hz
Output voltage
6V DC, 0.2A
75
PS-0602D, PS-0602C
Specifications (PS-0602D)
39.5
PS-0602D
PS-0602C
51
Used for
Input voltage & Capacity
230V AC, 50/60Hz.
Output voltage
6V DC, 0.2A
*Manufactured by Sino-American
C-123L/A, AT-406, LEM,
TAR-3
12V DC
167
PS-1225S, PS-1225UL
52
90
PS-1225S
PS-1225UL
PS-1225
(without AC cord)
Specifications (PS-1225S, PS-1225UL, PS-1225)
Input voltage & Capacity
100-240V AC, 50/60Hz 37W/6582VA
Output voltage
12V DC, 2.5A
POWER SUPPLIES
Unit dimensions
Used for
IE-1AD(U), IE-1GD(U), IE-2AD(U),
IE-2A2D(U), IE-8MD, LEM-1DL,
LEF, LEF-C, TD-H/B,
TD-Z/A, VC-M, MP-S,
NEW-5 (NEM), TB-AD10 (TC-M)
106
Power Supplies
18V DC
Unit dimensions
Used for
PS-1820S
52
90
IE-8MD, JB-2MED, JB-2MD, JBW-BA, JF-1MD, JF-2MED
MK-1GD, MK-2MCD, MY-CU, MYW-P1L(LEF), MYW-P3L(LEF)
TC-M, MYW-BA, KC-32EU, RY-3DL
167
Specifications (PS-1820S, PS-1820UL, PS-1820)
Input voltage & Capacity
100V-240V AC, 50/60Hz, 45W/75-95VA
Output voltage
18V DC, 2A
PS-1820S
PS-1820UL
PS-1820
(without AC cord)
24V DC
Unit dimensions
Used for
JA-2MECD, JA-2MCD, GF-BC, GF-VBC/A, GFW-VBC, MAW-B
MYW-BA, YAZ-90-3W, NEM-(A)/C, KC-1MRD, KC-1GRD
KB-3MRD, KC-32EU, RY-3DL, MU-100
PS-2410LD
164
Specifications (PS-2410LD)
220-240V AC, 50/60Hz 35W
Output voltage
24V DC, 1A
66
95
RD BK
(+) (–)
Specifications (PS-2410LC)
Input voltage & Capacity
120V AC, 50/60Hz 35W
Output voltage
24V DC, 1A
PS-2420S, PS-2420UL
52
90
Specifications (PS-2420S, PS-2420UL, PS-2420)
167
POWER SUPPLIES
PS-2410LD
PS-2410LC
PS-2420S
PS-2420UL
PS-2420
(without AC cord)
107
Input voltage & Capacity
RD : Red (+). BK : Black (-).
Input voltage & Capacity
100-240V AC, 50/60Hz 60W/100-125VA
Output voltage
24V DC, 2A
Communication Distance
The below graph is to assist you in determining the diameter of wires or communication distance required.
Example;
To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires;
1. On the graph;
Draw a line from IE-1AD(U) on point A 7.8, crossing the line B
at the point 0.8 to reach a point reading 225.
A
Distance
B
IE-1AD(U)
0.8
28
225 (m)
COMMUNICATION DISTANCE CALCULATION GRAPH
SYSTEM & MODELS
TB-AD1, AD10 [TC-M]
C-123L/A
IE-1GD(U) [IEH-1CD]
IE-2AD(U) [IEH-1CD]
IE-2A2D(U) [IEH-1C2D]
A
COMMUNICATION
DISTANCE
...m
FIXED NUMBER
FOR DISTANCE
BY ITEM
2,000
MP-1S, MP-3S
3.4
NEM-nA/C, NEM-n/C
3.9
5.2
TCS-MH
IE-1AD(U) [IF-DA]
IE-1GD(U) [IF-DA]
IE-2AD(U) [IF-DA], IE-2A2D(U)
DE-UR [IF-DA]
AP-1M/A, AP-5M/A, AP-10M/A
6.8
7.8
10.4
B
DIAMETER
mm
1.6
900
800
1.4
700
1.2
600
1.0
500
0.8
400
17.4
0.65
20.9
26.2
300
0.5
225
200
VC-nM, VCH [VC-K]
34.0
36.7
AT-206 [AT-306x3]
TC-M [TB-SE]
100
MC-60/4A
90
TD-1H, TD-3H, TD-6H
TD-12H, TD-24H
TD-6Z, TD-12Z
80
AT-406
50
70
60
COMMUNICATION DISTANCE
LEM-1, LEM-3
LEF-3, LEF-5 , LEF-10
LEF-10S
LEF-3C, LEF-5C, LEF-10C
1,000
40
30
20
NOTES;
IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station.
Video Intercoms are not included in the graph.
108
97
INDEX
PAGE
A
AI-900AF ............................................ 82
AI-900AL ............................................82
AI-900CO............................................82
AI-900DI ............................................82
AI-900MF............................................82
AI-900MS ...........................................82
AI-900RS............................................82
AI-900TI .............................................82
AI-910DI ............................................82
AI-MS900 ........................................... 81
AI-PN100B ......................................... 82
AI-PU200............................................ 82
AI-RS150............................................81
AI-RS160 ........................................... 81
AI-RS170 ........................................... 81
AI-RS180 ........................................... 81
AI-YC303 ............................................ 82
AP-10M ..............................................92
AP-1M ................................................92
AP-5M ................................................ 92
AS-3A ................................................. 91
AS-3N................................................. 91
AT-206 ................................................ 70
AT-306 ................................................ 70
AT-406 ................................................ 70
AT-406B/A .......................................... 70
AT-406P..............................................70
AX-084C .............................................78
AX-16SW............................................ 77
AX-248C ............................................. 78
AX-320C ............................................. 78
AX-8M ................................................ 77
AX-8MV .............................................. 77
AX-DM .......................................... 34,77
AX-DV................................................. 77
AX-DVF............................................... 77
AX-DVF-P............................................ 77
AX-DV-P ............................................. 77
PAGE
B
BG-10C............................................... 69
PAGE
C
C-123L/A ............................................ 28
C-D ..................................................... 28
C-ML/A................................................ 28
INDEX
D
PAGE
DA-1AG .............................................. 27
DA-1AS .............................................. 27
DA-1DG .............................................. 27
DA-1DS .............................................. 27
DA-1MD ........................................ 27,60
DA-2DG .............................................. 60
DA-2DS ............................................. 60
DA-4DG ..............................................
......................................... 60
DA-4DS .............................................. 60
DAR-1 ........................................... 27,60
DAW-P........................................... 27,60
DE-UR ................................................ 71
PAGE
G
GF-10K .............................................. 55
GF-10KP.........................................40,55
GF-1D ................................................ 57
GF-1DK .............................................. 57
GF-1MD ............................................. 57
GF-1MDK ........................................... 57
GF-1P ............................................ 39,55
109
GF-2B ............................................39,56
GF-2F ............................................ 39,56
GF-2P ............................................39,55
GF-3B ............................................39,56
GF-3F ............................................39,56
GF-3P ............................................39,55
GF-4P ............................................39,55
GF-4Z ................................................ 58
GF-AD ................................................ 55
GF-AP ............................................39,55
GF-BC ................................................. 58
GF-BP ............................................ 39,55
GF-DA ................................................. 55
GF-DP .................................................55
GF-GD-TS ........................................... 53
GF-GMK ............................................. 53
GF-GTX .............................................. 54
GF-MK ................................................ 57
GF-nH (n=102, 202, 103, 203, 303) .......39,56
GF-nHB (n=102, 202, 103, 203, 303)..... 39,56
GF-NS ................................................. 55
GF-NSP.......................................... 40,55
GF-SW ................................................55
GF-VA .................................................55
GF-VBC ...............................................58
GF-VP ............................................ 39,55
GFW-LD.............................................. 59
GFW-S ............................................43,57
GFW-VBC ........................................... 59
GH-10K .............................................. 40
GH-1AD .............................................. 42
GH-1KD .............................................. 42
GH-1KDS ............................................ 40
GH-1MD ............................................. 42
GH-4Z ................................................ 43
GH-AD ................................................ 39
GH-BC ................................................ 43
GH-BCX .............................................. 44
GH-CCTV............................................. 46
GH-DA ............................................... 39
GH-DP ................................................ 39
GH-HS ................................................ 42
GH-MK ............................................... 43
GH-NS ................................................ 40
GH-RY ................................................ 44
GH-SW................................................. 39
GH-VA ................................................ 39
GH-VBC .............................................. 43
GH-VBX .............................................. 44
GHW-LC ............................................. 45
PAGE
I
IAI-100 .............................................. 84
IAX-100 .............................................. 84
IE-1AD(U)........................................... 30
IE-1GD(U)........................................... 31
IE-2A2D(U)......................................... 32
IE-2AD(U)........................................... 32
IE-8HD................................................ 33
IE-8MD ............................................... 33
IE-DC .................................................. 34
IE-DL1 ................................................ 34
IE-DL2 ................................................ 34
IE-DL3 ................................................ 34
IE-FY................................................... 34
IEH-1C2D ........................................... 32
IEH-1CD ............................................. 31
IE-JA .................................................. 34
IER-2.................................................104
IF-DA .................................................. 34
IME-100 .............................................83
IME-150 .............................................84
IMU-100 ............................................. 83
ISE-100 ..............................................84
PAGE
J
JA-2HCD .............................................10
JA-2MCD ............................................ 9
JA-2MECD ............................................ 9
JA-2SD ............................................8,10
JA-D .................................................. 7,9
JA-DAC ................................................9
JA-DGC ...............................................9
JB-2HD .................................................8
JB-2MD ................................................7
JB-2MED ..............................................7
JB-DA ..................................................7
JB-DV ................................................... 7
JB-DVF ................................................. 7
JBS-2AD ...............................................8
JBS-2ADV.............................................8
JBS-2ADVF ...........................................8
JBS-2AED .............................................8
JBS-2AEDV...........................................8
JBS-2AEDVF......................................... 8
JBW-BA ...............................................18
JBW-D .................................................. 8
JDW-C .................................................. 9
JF-1MD .................................................3
JF-1FD ................................................. 4
JF-1SD.................................................. 4
JF-DA ................................................... 3
JF-DV ................................................... 3
JF-DVF.................................................. 3
JFS-1AD .............................................. 4
JFS-1ADV ............................................ 4
JFS-1ADF ............................................. 4
JF-2MED............................................... 5
JF-2HD ................................................. 6
JF-2SD ................................................. 6
JFS-2AED ............................................. 6
JFS-2AEDV ........................................... 6
JFS-2AEDF............................................ 6
K
PAGE
KA-DGR PANEL ..................................12
KAW-D ................................................18
KB-3HRD .............................................16
KB-3MRD.............................................15
KB-3SD ...............................................16
KB-DAR ..............................................15
KC-1GRD.............................................13
KC-1HRD.............................................14
KC-1MRD ............................................11
KC-1SD ...............................................14
KC-32EU ........................................17,25
KC-DAR .........................................11,13
KCS-1ARD ..........................................12
L
PAGE
LE-A ..................................................69
LE-A3 .................................................69
LE-AN .................................................69
LE-AN3................................................69
LE-B ...................................................69
LE-BN ................................................. 69
LE-C ...................................................69
LE-CN .................................................69
LE-D ...................................................69
LE-DA .................................................69
LE-DL ..........................................69
LEF-10 .........................................65
LEF-10C ..................................24,67
LEF-10S .......................................66
LEF-10W ......................................65
LEF-1C .........................................69
LEF-20(S) ....................................66
LEF-3 ...........................................65
LEF-30(S) ....................................66
LEF-3C ....................................24,67
LEF-40(S) ....................................66
LEF-5 ...........................................65
LEF-5C ....................................24,67
LEF-5W ........................................65
LEM-1 ......................................... 64
LEM-1DL .....................................63
LEM-3 .........................................64
LEW-10 .......................................66
LEW-10S ..................................... 66
LEW-5 ......................................... 66
M
PAGE
MAW-B.......................................105
MC-60/4A ....................................90
MC-60/4B ....................................90
MC-A/A ........................................90
MCW-S ........................................18
MK-1GD .......................................19
MK-1HD.......................................20
MK-2DA ......................................25
MK-2DG ......................................25
MK-2DG PANEL ..........................25
MK-2HCD ....................................22
MK-2MCD ...................................21
MK-2SD .......................................20
MK-D ...........................................22
MK-DAC ......................................21
MK-DBC ...................................... 21
MK-DGC ......................................21
MK-DH ....................................19,21
MK-DV ........................................19
MK-DVF ......................................19
MKS-1GD ...................................20
MKS-1GDV ..................................20
MKS-1GDVF ................................20
MKW-P ........................................20
MKW-R .......................................22
MP-1S .........................................91
MP-3S .........................................91
MY-CU ........................................23
MYH-CU .....................................23
MYH-CUB ....................................24
MYW-BA .....................................26
MYW-P1L .............................. 24,68
MYW-P3L .............................. 24,68
PAGE
NA-A ...................................... 85,99
NA-AN .................................... 85,99
NA-NE .................................. 85,100
NAR-2A .....................................100
NAR-3 ........................................100
NAR-6A .................................. 86,99
NA-T/A ................................. 86,100
NBJ-20 ......................................102
NBJ-20B ....................................102
NBJ-40 ......................................102
NBJ-40B ....................................102
NB-L .....................................85,100
NBR-7AS .............................86,100
P
PAGE
PD-1 .................................................. 72
PD-2 .................................................. 72
PS-0602C .........................................106
PS-0602D .........................................106
PS-1225 ...........................................106
PS-1225S .........................................106
PS-1225UL .......................................106
PS-1820 ............................................107
PS-1820S .........................................107
PS-1820UL .......................................107
PS-2410LC .......................................107
PS-2410LD .......................................107
PS-2420 ...........................................107
PS-2420S .........................................107
PS-2420UL .......................................107
PT-1211C .........................................106
PT-1211D .........................................106
R
PAGE
RY-3DL ..........................................18,26
RY-AC/A ............................................104
RY-PA ...............................................104
T
PAGE
TAR-3 ................................................105
TB-AD1 ...............................................88
TB-AD10 .............................................88
TB-ADD...............................................88
TB-ADM10 .........................................89
TB-SE .................................................87
TC-10M ..............................................87
TC-10MD............................................ 88
TC-20G............................................... 87
TC-20M ..............................................87
TC-40G ............................................... 87
TC-40GS ............................................ 87
TC-DC ................................................ 29
TC-MH ............................................... 29
TCS-MH ............................................. 29
TD-12H/B ........................................... 72
TD-12Z/A ........................................... 72
TD-1H/B ............................................. 71
TD-24H/B ...........................................72
TD-3H/B ............................................. 71
TD-6H/B ............................................. 71
TD-6Z/A ............................................. 72
TDW-1/A ............................................ 72
TDW-12/A .......................................... 72
TDW-24/A .......................................... 72
TDW-3/A ............................................ 72
TDW-6/A ............................................ 72
V
PAGE
VC-0M ............................................... 61
VC-10M .............................................. 61
VC-1M ................................................ 61
VC-26MT ............................................ 62
VC-26MY............................................ 62
VC-2M ................................................ 61
VC-42MY............................................ 62
VC-4M................................................ 61
VC-58MT............................................ 62
VC-6M................................................ 61
VC-8M................................................ 61
VC-BBX .............................................. 62
VCH-16 .............................................. 61
VCH-8 ................................................ 61
VC-K .................................................. 61
VGX-D-YBOX
51
W
PAGE
W-DIN11 ............................................ 57
Y
PAGE
YAZ-90-3W......................................... 74
INDEX
N
NBR-7AS-S ......................................100
NBR-8A ............................................100
NB-U.................................................102
NBY-1A ............................................100
NBY-4A ............................................100
NBZ-M ............................................... 91
N-EA .................................................. 91
NE-JA .........................................86,100
NEM-10/C ..................................... 85,99
NEM-100 ....................................... 86,99
NEM-100A .................................... 86,99
NEM-10A/C ................................... 85,99
NEM-110 ....................................... 86,99
NEM-110A..................................... 86,99
NEM-120 ....................................... 86,99
NEM-120A..................................... 86,99
NEM-20/C .....................................85,99
NEM-20A/C ...................................85,99
NEM-30/C .....................................85,99
NEM-30A/C ...................................85,99
NEM-40/C .....................................85,99
NEM-40A/C ...................................85,99
NEM-50 .........................................86,99
NEM-50A ......................................86,99
NEM-60 .........................................86,99
NEM-60A........................................86,99
NEM-70 ........................................86,99
NEM-70A .......................................86,99
NEM-80 ......................................... 86,99
NEM-80A ...................................... 86,99
............................................ 86,99
NEM-90
NEM-90A ...................................... 86,99
NEW-5 ..............................................103
NH-1SA/A .......................................... 96
NH-2SA/A ......................................... 96
NHR-30K ........................................... 95
NHR-3A-4 .......................................... 96
NHR-3TS ........................................... 96
NHR-4A/A ......................................... 96
NHR-7A ............................................. 96
NHR-8A ............................................ 96
NHR-DP.............................................. 96
NHR-SP.............................................. 95
NHX-30G ........................................... 95
NHX-50M ........................................... 95
NHX-80X ........................................... 95
NP-B .................................................. 91
NP-W ................................................. 91
NR-4AS13 ........................................100
110