Download Aiphone JA-2MECD Specifications
Transcript
C o n t e n t s AUDIO ENTRY SECURITY COLOR VIDEO ENTRY SECURITY 1 1 Two-Wire Electric Lock Door Phone 3 1 1 Chime Tone Intercom 5 1 1 Chime Tone Intercom 7 1 1 Chime Tone Intercom 9 1 3 Chime Tone Intercom 11 2 3 Chime Tone Intercom 13 2 6 Chime Tone Intercom 15 1 1 Hands-free Color Video Intercom 2 3 Hands-free Color Video Intercom, Picture Memory 2 3 Hands-free Color Video Intercom 2 3 Hands-free Color Video Intercom, PanTilt, Picture Memory 1 1 Video Sentry Color Tilt 1 3 Video Sentry Color Tilt 3 5 Video Sentry Color Tilt JF-1MD JF-2MED JB-2MED JA-2MECD KCS-1ARD KC-1GRD KB-3MRD DA-1AS 27 C-123L/A 28 TCS-MH 29 IE-1AD(U) 30 IE-1GD(U) 31 IE-2A2D(U) 32 IE-8MD 33 Audio Door Stations 34 Color Video Accessories KC-32EU JBW-BA, RY-3DL, KAW-D, MCW-S 17 18 MULTI-UNIT ENTRY SECURITY Hands-free Color Video Bus Apartment System GH SYSTEM BLACK & WHITE VIDEO ENTRY SECURITY 1 3 Wide Angle Video Sentry 2 3 PanTilt Video Sentry 1 6 PanTilt Video Sentry 3 8 Master Sentry 35~48 35 System outline MK-1GD 19 MK-2MCD 21 5 48 Standard System configuration 37 16 500 Expanded System configuration 38 39 42 43 45 46 47 48 Entrance station MY-CU & IE-8MD 23 Residential station Security guard station, Control unit LEF-C Video 24 GH lift control adaptor B&W Video Accessories GH CCTV camera interface adaptor for Reception MK-2DA, MK-2DG, KC-32EU MYW-BA, RY-3DL, IER-2 25 26 Cabling (standard) Wiring (standard) Bus Apartment System 49~59 GF SYSTEM Two-Wire Bus System 5 100 GF Audio 49 Four-Wire Common B&W Video System 5 100 GF Audio/Video 51 Two-Wire Bus System 8 4,800 GF Multi-Tower Example 2 DOOR ENTRANCE MASTER SERVICE SIDE STATION 3 ROOM RESIDENCE SUB PUBLIC SIDE 53 GF Components 1 4 55 Two-Wire Electric Lock Door Phone DA-4DS 60 Audio Entry Security 1 58 VC-M SINGLE-FAMILY HOME MULTI-TENANT COMMERCIAL BUILDING FACTORY 61 OFFICE SCHOOL COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM 1 1 Open Voice Intercom 1 3 Open Voice Intercom 11 LEM-1DL LEM LEF Open Voice Intercom 3 8 Open Voice Intercom 25 COLOR VIDEO ENTRY SECURITY 64 Open Voice Intercom 3 8 1 3 63 LEF-C 65 67 LEF & MYW-P1L/P3L 68 LE Sub stations & Accessories 69 BLACK & WHITE VIDEO ENTRY SECURITY Handset Intercom AT-406 70 Handset Intercom TD-H/B lTD-Z/A 71 Handset Intercom 1 24 TD-H/B & MY-CU 90 73 Handset Intercom YAZ-90-3W AUDIO ENTRY SECURITY 74 Integrated Security & Communication System 8 120 AX Security Intercom 64 1,024 Commercial AI-900 1 1 75 79 Security Window Intercom IMU-100 83 MULTI-UNIT ENTRY SECURITY Master / Sub Intercom 1 120 NEM 85 Master / Sub Intercom 2 100 TC-M 10 1 Master / Sub Intercom 10 1 Master / Sub Intercom 60 Market-Com 1 3 TC-M & TB-AD10 TC-M & TB-ADM10 MC-60/4A 87 88 89 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM 90 Mid-Power Intercom MP-S 91 High-Power Intercom 2 10 AP-M 92 Nurse Call 1 80 NHX 93 Nurse Call 1 120 NEM 99 ACCESSORIES & POWER SUPPLIES ACCESSORIES & POWER SUPPLIES Accessories IER-2, RY-AC/A, TAR-3, MAW-B Power Supplies 104 106 COMMUNICATION DISTANCE & INDEX Communication Distance Index 108 109 COMMUNICATION DISTANCE & INDEX Communication Systems for business, home and industry Established In 1948 Aiphone has become the most respected and reliable brand of communication systems in the world. With headquarters in Nagoya and manufacturing in Toyota City, Central Japan, we export to over 60 countries. We expand ourselves along with a North American marketing, sales and distribution center near Seattle, Washington, and a European sales and distribution center Lisses-Evry, France. Systems For Every Application Aiphone products range from simple do-it-yourself door answering units to sophisticated video entry security systems, complex microprocessor-based commercial systems, and luxury condo/apartment security/communication systems. They are unrivaled in design simplicity, technical excellence and reliability. With over 30 standard systems, and additional manufacturing by special order, we can create a system for virtually any intercom application. Designed To Last Every Aiphone system is the result of painstaking attention to detail: contemporary European style design, the finest quality hardware and circuitry, engineered, built and 100% pre-tested for sustained trouble-free service. ISO 9001 Aiphone is the first intercom manufacturer worldwide to receive ISO 9001 certification, and the only one selling in North America, An agency representing the International Standards Organization (ISO), headquartered in Geneva, Switzerland, graded Aiphone against guidelines for design and development, production, and product inspection and testing. ISO 9001 standards provide an immediate recognition of product quality almost anywhere in the world. Winner Of The Deming Prize Aiphone is the first and only intercom manufacturer to win the Deming Prize, the highest international award for quality control. Named in honor of Dr. W. Edwards Deming, the award honors firms worldwide which advance and maintain manufacturing quality. Acquisition of ISO 14001 ISO's Environmental Standards are a series of voluntary standards and guideline reference documents which include environmental management systems, eco-labeling, environmental auditing, life cycle assessment, environmental performance evaluation, and environmental aspects in products standards. In early 1998, our management team determined to acquire ISO-14001 approval as a company-wide project, and working committee was established at the same time. Since then, with our ongoing efforts and practice about environmental management standards, we have succeeded to acquire the approval. Aiphone excludes the use of prohibited material from the product according to RoHS directive (2002/95/EC). Therefore, as of July 1, 2006, all the Aiphone products imported in EUwill be fully complied with the RoHS directive. ISO 9001 Certified ISO 14001 Certified JQA-0291 JQA-EM0453 AIPHONE CO., LTD. Toyota Factory AIPHONE CO., LTD. Deming Prize ENVIRONMENTAL REPORT We will contribute to building a sustainable society while cultivating communications with a wide spectrum of our stakeholders. Basic Environmental Philosophy Revised October 1, 2005 Based on our business philosophy of "Be Responsible for your job and don't cause of problems for others," we carry out our activities while harmonizing conservation of the global environment with our business operations. Environmental Policy The AIPHONE group aspires to be enterprises capable of making contributions to society by using communication and security technologies, conducting our environmental activities as follows: (1) We will strive to minimize environmental loads to conserve the global environment in our activities of developing, producing, selling, and servicing our products. (2) We will make our goals and objectives clear in our business activities, continuously evaluating the following items and thus improving them: a) We will aim to become a recycling society and make efforts to promote the 3R's (Reduce, Reuse, and Recycle) and minimize waste. b) We will not use harmful substances that cause environmental contamination. c) We will strive to conserve energy to prevent global warming. (3) We will conform to environment-related laws, regulations, and conventions while establishing voluntary standards to conserve the environment. (4) Placing great value on communication, we will promote the manufacture of products friendly to both humans and the environment. (5) We will conduct environmental audits in an effort to maintain and improve our environment management system. (6) We will make our environmental policy thoroughly known to our employees and all those who work together with us. (7) We will publicize this environmental policy to the general public. Certificate of acquisition of ISO 14001 accreditation This report is also posted on our website: http://www.aiphone.co.jp/english/ 1 Hands-free Color Video Intercom DOOR Features ROOM 1 • One door & two monitors (3-1/2 inch); room to room communication is not available • Total hands-free communication, auto-voice actuation • Streamlined & Thin design, only 27 mm thickness • Vandal resistant video door stations are available • White LED illumination turns on in low-light conditions 1+1 JF-1MD Door station Master station COLOR VIDEO ENTRY SECURITY 2 IER-2 2 2 PT Call extension m P.104 PS18 JF-DV Vandal-resistant video door station, surface mount JF-1MD Master station w/color monitor or or JF-DA JF-DVF Standard video door station Vandal-resistant video door station flush mount Power supply PS-1820S PS-1820UL PS-1820 m P.107 Communication network Wiring 100m / 1.0mma JF-DV JF-1MD JF-1FD JF-1MD 2 6 JF-1SD 6 JF-DV DOOR A1 A2 A1 A2 M Electric door strike JF-1SD PT CALL EXT IER-2 S S 1 E SUB SUB B1 B2 B1 B2 DOOR RELEASE DOOR RELEASE L L L L DC18V DC18V JF-1FD PS18 (BR) (RD) Room-to-room communication is not available. BR: Brown RD: Red (BR) External device (RD) PRESS TALK PRESS TALK ON OFF ON OFF PS18 External device : PS-1820/S/UL PT : AC Transformer Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. 3 • • • • • • Instant voice call-in with image Visual monitoring with audio for 1 minute Press-to-talk operation available Talk LED lights in red while speaking Optional audio sub station (JF-1SD) Option - Option button, press-to-talk setting Lineup Sub station JBW-BA Long distance adaptor m P.18 *Max. 300m away from Master/sub to Door. JF-1FD Sub station w/color monitor or 6 JF-1SD Audio sub station COLOR VIDEO ENTRY SECURITY 6 KAW-D 30k angled box m P.18 Boxed sets JFS-1AD: JF-1MD, JF-DA JFS-1ADV: JF-1MD, JF-DV JFS-1ADF: JF-1MD, JF-DVF Add appropariate power supply Unit dimensions Electric door strike (locally available) Image view area JF-DA, JF-DV, JF-DVF JF-1MD, JF-1FD JF-1SD (2) 210 179 (1) 27 135 JF-DV 82 JF-DVF 27 (3) 65cm 70cm 65cm 50cm 95cm 40 5.5 JF-DA 131 209 173 (1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only) Specifications (JF-1MD) 99 98 25 135 29 108.5 120 88 Power source Power supply Consumption Calling Communication JBW-BA 83.5 IER-2 45 40 122.5 61 Video monitor Scanning line Night viewing Door release Wiring Wiring distance 18V DC PS-1810DIN Max. 450mA (JF-1MD). Max. 300mA (JF-1FD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3-1/2 inch direct-view TFT color LCD. 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 6-cond., mid cap, solid, non-shielded. Master/Sub (farthest room station) to door: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma) 4 Hands-free Color Video Intercom Features DOOR ROOM 2 3 JF-2MED • Two doors & three monitors (3-1/2 inch) • Total hands-free communication, auto-voice actuation • Built-in picture memory; Record visitor both automatically & manually • Voice memo; Internal short voice messages can be recorded and played back Door station Master station COLOR VIDEO ENTRY SECURITY 4 2 2 2 IER-2 Call extension m P.104 PT JF-DV Vandal-resistant video door station, surface mount JF-2MED Master station w/color monitor and picture memory 2 or or JF-D JF-DA JF-DVF Vandal-resistant video door station flush mount Audio only door station Standard video door station Power supply PS-1820S PS-1820UL PS-1820 m P.107 Communication network Wiring 100m / 1.0mma 100m / 1.0mma JF-DV JF-DV JF-2HD JF-2MED 2 2 4 JF-2SD JF-2MED or 2 A1 A2 NP A1 A2 PS18 DOOR2 A1 A2 NP SUB B1 B2 CALL EXT S S Electric door strike M (BR) (RD) JF-2SD JF-2SD or 2 2 IER-2 DOOR1 A1 A2 JF-2HD 4 JF-2SD 2 JF-DVF M JF-2HD RELEASE NP IER-2 1 E ON OFF ON OFF SUB IN SUB OUT SUB IN SUB OUT B1 B2 B1 B2 B1 B2 B1 B2 L L PT PS18 DC18V DC18V JF-2HD JF-DVF Selective control of door release at communicating Door station. All-Call the inside stations by voice, then talk individually. RY-3DL Connection JF-2MED RY-3DL Electric door strike Picture memory 3/16 2006 02 DEC 18 : 45 L1 C1 L1 L2 C2 L2 • Plays 8 shots continuously so that you can see them as a moving image. Pause and frame-by-frame play are also available. 8 shots/picture Electric door strike PT b1 b2 b3 L D1 E D2 OG YE GR BR RD b1 b2 E L L DC18V PRESS THE TALK BUTTON TO END BR: Brown RD: Red OG: Orange YE: Yellow GR: Green PS18 : PS-1820/S/UL PT : AC Transformer 5 PS18 • Message for entrance; Outgoing messages can be recorded and sent out at the door station manually • Streamlined & Thin design, only 32 mm thickness • Vandal resistant video door stations are available • White LED illumination turns on in low-light conditions • Visual monitoring with audio for 1 minute • External sensor connectable for notifying and pictograph on monitor • Instant voice call-in with image • • • • • • • • Different chimes to indicate which door is calling Press-to-talk operation available All-Call for internal communication Transfer of door station call to other inside stations Selective door release control (with RY-3DL) Optional audio sub master station (JF-2SD) Audio door station in lieu of 2nd video door station Option - Option button, Video signal (NTSC) output, External talk switch, press-to-talk restriction Lineup Sub station Sub master station w/color monitor Sub master station w/color monitor 4 or 2 or RY-3DL JBW-BA Door release adaptor m P.18 Long distance adaptor m P.18 *Max. 300m away from Master to Door 2 JF-2SD JF-2SD Audio sub master station Audio sub master station KAW-D COLOR VIDEO ENTRY SECURITY JF-2HD JF-2HD 30k angled box m P.18 Boxed sets JFS-2AED: JF-2MED, JF-DA JFS-2AEDV: JF-2MED, JF-DV JFS-2AEDF: JF-2MED, JF-DVF Add appropariate power supply Electric door strike (locally available) Unit dimensions Image view area JF-DA, JF-DV, JF-DVF JF-2MED, JF-2HD JF-2SD JF-DV 27 (2) 135 JF-DVF 90 32 5.5 173 160 179 (1) 25 98 JF-DA (3) 65cm 70cm 65cm 50cm 95cm 25 JF-D 209 131 130 (1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only) Specifications (JF-2MED) 99 RY-3DL 29 108.5 JBW-BA 83.5 120 Power source Power supply Consumption Calling Communication 28.5 45 IER-2 88 40 140 135 98 122.5 Video monitor Scanning line Night viewing 61 74 42 Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. Door release Wiring Wiring distance 18V DC PS-1810DIN Max. 400mA (JF-2MED). Max. 220mA (JF-2HD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3-1/2 inch direct-view TFT color LCD. 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 4-cond., mid cap, solid, non-shielded. Master to door: 50m (0.65mma) 100m (1.0mma) Master to farthest sub: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma) 6 Hands-free Color Video Intercom Features DOOR ROOM 2 3 JB Series • • • • • Door station Two color doors, three inside monitor stations (3-1/2 inch LCD) Total hands-free communication, auto-voice actuation Built-in picture memory (JB-2MED only) Instant voice call-in with image Press-to-talk operation available Master station COLOR VIDEO ENTRY SECURITY Picture memory 4 2 IER-2 2 2 Call extension m P.104 PT Standard Non-Picture memory JB-DV PS18 Vandal-resistant video door station, surface mount or JB-2MED Master station w/color monitor and picture memory 2 or or PS18 JB-2MD Master station w/color monitor JA-D JB-DA JB-DVF Vandal-resistant video door station flush mount Standard video door station Power supply PS-1820S PS-1820UL Audio only door station PS-1820 m P.107 Communication network Wiring 100m / 1.0mma JB-DV 100m / 1.0mma JB-2HD JB-2MD, JB-2MED JA-2SD JB-2MD, JB-2MED JA-2SD JB-2HD DOOR1 A1 A1 2 A2 A2 NP ON OFF DOOR2 JA-2SD A1 A1 A2 A2 SUB SUB NP SUB IN OUT B1 B1 B1 B2 B2 B2 IER-2 JB-DV CALL EXT 1 S E S Electric door strike RELEASE NP BR L RD L DC18V JB-2HD JB-DVF 2 ON OFF SUB IN B1 B2 JA-2SD SUB OUT B1 B2 DC18V PT JB-2HD PS18 JB-DVF RY-3DL Electric door strike Selective control of door release at communicating Door station. All-Call the inside stations by voice, then talk individually. L1 C1 L1 Electric door strike Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. 7 PT L2 C2 L2 OG b1 YE b2 b1 b2 b3 L D1 E D2 JB-2MD, JB-2MED BR RD L L DC18V PS18 BR: Brown RD: Red OG: Orange YE: Yellow PS18 PT : PS-1820S/UL PT : AC transformer • • • • • • • • • • • • • White LED illuminator turns on in low-light conditions Door call-in LED lights in red or green Different chimes to indicate which door is calling All-Call for internal communication Transfer of door station call to other inside stations Optional audio sub station (JA-2SD) Audio door station in lieu of JB video door station Talk LED lights in red while speaking Selective door release control (with RY-3DL) Visual monitoring with audio for 30 seconds Video output via supplied connector (NTSC) Sensor connectable for alarming and pictograph on monitor (JB-2MED only) Option - Foot talk switch Lineup Sub station Sub master station w/color monitor Sub master station w/color monitor 4 2 or RY-3DL JBW-BA Door release adaptor m P.18 Long distance adaptor m P.18 KAW-D o Electric door strike (locally available) 2 or JA-2SD JA-2SD Audio sub master station Audio sub master station Boxed sets 30 angled box m P.18 COLOR VIDEO ENTRY SECURITY JB-2HD JB-2HD JBW-D o 15 angled box JBS-2AD: JB-2MD & JB-DA JBS-2ADV: JB-2MD & JB-DV JBS-2ADVF: JB-2MD & JB-DVF JBS-2AED: JB-2MED & JB-DA JBS-2AEDV: JB-2MED & JB-DV JBS-2AEDVF: JB-2MED & JB-DVF Add appropriate power supply Add appropriate power supply Unit dimensions Image view area JB-DA, JB-DV & JB-DVF JB-2MD, JB-2HD JB-2MED JA-2SD (2) (1) (3) 70cm 65cm 210 175 175 65cm 50cm 43 115 43 115 82 40 95cm (1) Initial horizontal view (2), (3) When camera is turned up or down (JB-DA only) 5.5 JB-DA JA-D 209 99 25 98 135 JBW-BA 29 40 28.5 98 RY-3DL 61 74 Calling Communication Video monitor Scanning line Night viewing Door release Wiring 140 108.5 120 122.5 88 Power source Power supply Consumption 45 83.5 IER-2 Specifications (JB-2MD, JB-2MED, JB-2HD, JA-2SD) 130 JB-DVF 131 27 173 JB-DV 42 Wiring distance DC 18V PS-1820S, PS-1820UL Max. 670mA(JB-2MD). Max. 770mA(JB-2MED) Max. 250mA(JB-2HD). Max. 120mA(JA-2SD) Chime. Image & audio, approx. 30 sec. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 2 sec. or until talk LED turns on. 3-1/2 inch direct-view TFT color LCD. 525 lines White LED projected up to 30cm from camera AC 12V, 400mA (dry closure contact L, L) 4-wire parallel, station to station(non-twisted nor shielded). Vinyl-jacket, PE insulation. Master station ~ Door 50m(0.65mma) 100m(1.0mma) Master station ~ farthest sub 50m(0.65mma) 100m(1.0mma) Master station ~ IER-2 75m(0.65mma) 150m(1.0mma) 8 PanTilt Hands-free Color Video & Motion-sensor camera integration Features DOOR ROOM 2 3 JA Series • Two color PanTilt Camera door stations, three inside monitor stations (4 inch LCD) • Motion-sensor camera (max.2) • Built-in picture memory (JA-2MECD only) • Surveillance mode SET through sensor-cameras. Activates monitor and internal alarming (& picture save in JA-2MECD) Door station Master station COLOR VIDEO ENTRY SECURITY Picture memory 2 2 2 PT 4 2 IER-2 PT 2 Call extension m P.104 PS24 Standard or Non-Picture memory JA-DGC PanTilt color video door station - semi-flush mount JA-2MECD 2 PanTilt color monitor master station, picture memory 2 or JA-DAC PanTilt color video door station - surface mount JA-D Audio only door stationsurface mount Power supply PS-2420S PS-2420UL JDW-C Motion-sensor camera Motion-sensor camera JA-2MCD PanTilt color monitor master station PS-2420 m P.107 Communication network JA-DGC PS24 JDW-C Wiring 100m / 1.0mma JA-2HCD 100m / 1.0mma 2 JA-DGC JA-DAC JDW-C M JDW-C 2 or JA-2MECD JA-2MCD JDW-C 2 JA-2HCD JA-2HCD 4 4 2 JA-2SD JA-2SD JA-2SD Electric door strike A1 A2 JA-DAC JA-D 1 2 NP JDW-C NP A1 A2 JDW-C M or NP C1 C2 A1 B1 B1 B1 B1 B1 A2 B2 B2 B2 B2 B2 Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. NP C1 C2 JA-2HCD DOOR2 DC24V A1 + + + A2 - - - ADAPTER -1 PS24 OFF ADAPTER -2 BR PT Electric door strike RD OG PT YE CALL EXT S S C1 C2 Electric door strike A A C1 C2 JDW-C JA-2SD M Door release activation Hands-free voice-activated communication after TALK button is pressed. 9 DOOR1 or JA-2MECD, JA-2MCD JA-DAC NP or 2 or 2 PT JA-DAC IER-2 NP 1 E L1 L1 L2 L2 Wiring for JA-2SD; Two wires only. + / - wires are not necessary. B1,B2: marked with SUB IN , SUB OUT PS24 :PS-2420S/DIN PT : AC transformer BR: Brown RD: Red OG: Orange YE: Yellow ON • • • • • • • • • • • • Total hands-free communication, auto-voice actuation Instant voice call-in with image Press-to-talk available White LED illuminator turns on in low-light conditions All Call for internal communication Transfer of door station call to other inside stations Optional video (JA-2HCD) or audio (JA-2SD) sub stations Audio door station in lieu of JA video door station Talk LED lights in red while speaking Visual monitoring with audio through all cameras Two door release contacts for selective control Options: -Foot talk switch -Manual Talk switch restriction -RY-3DL for large door releases locally available -Video output to video device (NTSC) Lineup Sub station JA-2HCD PanTilt color monitor sub master station PanTilt color monitor sub master station 4 KAW-D Electric door strike (locally available) 30k angled box m P.18 JBW-D 15k angled box 2 or or 2 JA-2SD JA-2SD Audio sub master station Audio sub master station COLOR VIDEO ENTRY SECURITY JA-2HCD JBW-BA Long distance adaptor m P.18 Unit dimensions Image view area JA-DAC, JA-DGC JA-2MECD JA-2MCD, JA-2HCD JA-DGC 50cm 220cm 210 210 172 90cm 180cm 130cm 180cm 65cm 42 JA-2SD JA-D 98 40 JBW-BA 29 102 93.5 Calling Communication Video monitor Scanning line Night viewing Door release Wiring 108.5 83.5 120 122.5 88 Power source Power supply Consumption 28.5 82 IER-2 45cm 90cm Max. pan-and-tilt view area: 90cm Vert., 180cm Horiz. (approx.) JDW-C 210 98 44 47.5 50cm Specifications (JA-2MECD, JA-2MCD, JA-2HCD, JA-2SD) 130 130 JA-DAC 12.5 19 37 182 160 115 42 160 61 Wiring distance DC 24V PS-2420S, PS-2420DIN Max. 750mA(JA-2MECD).Max. 680mA(JA-2MCD). Max. 290mA(JA-2HCD). Max. 120mA(JA-2SD) Chime. Image & audio, approx. 30 sec. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 2 sec. or until talk LED turns on. 4 inch direct-view TFT color LCD. 525 lines White LED projected up to 30cm from camera. AC 12V, 350mA (dry closure contact L, L) Parallel, station to station(non-twisted, non- shielded). Vinyl-jacket, PE insulation. Master station ~ Door 50m(0.65mma) 100m(1.0mma) Master station ~ Motion sensor camera 50m(0.65mma) 100m(1.0mma) Master station ~ farthest sub 50m(0.65mma) 100m(1.0mma) Master station ~ IER-2 50m(0.65mma) 100m(1.0mma) 10 Video Sentry Color Tilt DOOR ROOM 1 1 KCS-1ARD Door station Features • Clear and bright image with color TFT LCD monitor and DSP video door station • TILT camera control • INSTANT ON audio & image of entry when called Master station COLOR VIDEO ENTRY SECURITY 2 2 2 PT KC-DAR PS24 Video door station KC-1MRD Master station Power supply PS-2420S PS-2420UL Communication network PS-2420 m P.107 Wiring 100m / 1.0mma 100m / 1.0mma KC-1MRD KC-DAR IER-2 2 KC-DAR KC-1MRD NP 4-tone chime M Tilt camera control 2 2 A1 A2 M N H A1 A2 S S + – 1 E N Electric door strike H l Run audio/video wires in a separate jacketed cable from door release wires. N : PS-2420S/UL H : AC transformer Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. 11 • Hands-free monitoring audio & image of door • Video door station's white LED illumination automatically turns on in the darkness • Locator LED backlight on CALL button Lineup KAW-D Picture memory unit m P.17 30k angled box m P.18 KA-DGR PANEL Boxed sets Electric door strike (locally available) KCS-1ARD JBW-BA IER-2 Call extension m P.104 Stainless steel housing for KC-DAR Long distance adaptor m P.18 KC-1MRD boxed set Unit dimensions Image view area KC-DAR KC-DAR KC-1MRD 124cm ★ 235cm 130cm 83.5 195 83.5 140 105 COLOR VIDEO ENTRY SECURITY KC-32EU 111cm ★ 50cm ★ 60cm ★ 50cm 44 * approximate 185 JBW-BA 61 83.5 120 122.5 KA-DGR PANEL 142 KAW-D 83.5 55.4 107 105 Video monitor Scanning lines Image view area 29 4.5 Night viewing Door release Wiring Distance 151 88 109 Specifications (KC-1MRD) Power source Power supply Communication 108.5 IER-2 88 42 24V DC, 450mA. 50mA standby PS-2420S, PS-2420UL Door calls in w/4-tone chime & image, 30 sec. timed. Lift handset to reply, 2-1/2 min. timed. In standby, press MONITOR to view and hear door. 4 inch TFT color LCD 525 lines Approx. 60cm horiz., 111~235cm vert. at 130cm high and 50cm from camera. White light projected up to 30cm from camera. The background scene beyond 30cm cannot be seen. 12V AC, 400mA. 2 parallel wires to door, non-polarized. KC-1MRD ~ door 50m(0.65mma) 100m(1.0mma) KC-1MRD ~ IER-2 50m(0.65mma) 100m(1.0mma) 30˚ 12 Video Sentry Color Tilt DOOR ROOM 1 3 KC-1GRD Door station Features • • • • VIDEO SENTRY COLOR TILT 1 door - 3 monitors INSTANT ON door audio & video All call type room calling 100m distance between monitors, looped Master station COLOR VIDEO ENTRY SECURITY 2 2 IER-2 2 2 Call extension m P.104 2 PT KC-DAR Video door station KC-1GRD Master station 2 PS24 PS24 Power supply PS-2420S PS-2420UL PS-2420 m P.107 Communication network Wiring 100m / 1.0mma 100m / 1.0mma IER-2 KC-1HRD 4-tone chime 2 2 KC-1SD KC-DAR KC-1HRD KC-1GRD KC-DAR NP KC-1GRD KC-1GRD 2 2 2 2 M Tilt camera 2 2 N N H (1) M KC-1SD A KC-1SD KC-1HRD A1 A2 A1 B1 A2 B2 + - N KC-1HRD B A1 B1 A2 B2 A + + - N Electric door strike B A1 B1 A2 B2 or A H B A1 S S 1 E A2 l Run audio/video wires in a separate jacketed cable from door release wires. N : PS-2420S, PS-2420UL H : AC transformer Cable (1) All call type voice calling (from any). Communication on handsets individually. 13 Vinyl jacketed, PE (polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. • TILT camera control • Hands-free monitoring audio & image of door • Video door station's white LED illumination automatically turns on in the darkness Lineup Sub station KC-1HRD KA-DGR PANEL KC-32EU Stainless steel housing for KC-DAR Picture memory unit m P.17 KAW-D 30k angled box m P.18 Electric door strike (locally available) JBW-BA MCW-S KC-1HRD Sub master station Sub master station or or 2 2 2 KC-1SD* KC-1SD* Audio sub station *Not available in Europe Audio sub station *Not available in Europe Long distance adaptor mP.18 83.5 210 83.5 74 IER-2 83.5 120 140 83.5 JBW-BA 122.5 29 88 44 Power supply Video monitor Scanning lines Communication 108.5 195 100 KC-DAR KA-DGR PANEL 83.5 107 4.5 55.4 109 61 Image view area Night viewing Door release Wiring 151 142 KAW-D 105 Power source Consumption KC-1SD 88 105 Monitor desk stand mP.18 Specifications (KC-1GRD) Unit dimensions KC-1GRD, KC-1HRD 185 COLOR VIDEO ENTRY SECURITY 2 42 Distance 30˚ 24V DC KC-1GRD: 450mA. 70mA standby. KC-1HRD: 200mA. 50mA standby. KC-1SD: 70mA. 50mA standby. PS-2420S, PS-2420UL 4 inch TFT color LCD 525 lines Door calls in w/4-tone chime, 30 sec. Hear and see door instantly. Pick up at any station to reply, 2-1/2 min. timed. Recycle with MONITOR. Monitor hands-free audio & image of door w/MONITOR. Press ALL CALL to call the other w/pretone & voice. Lift either handset to reply. Approx. 60cm Horiz., 111~235cm Vert. at 50cm in front of camera at 130cm high. Up to 30cm from camera, with white LED projected. Background scene beyond 30cm cannot be seen. Contact rating: 12V AC, 400mA. 2 parallel wires to door, non-polarized. 2 wires in loop between monitors, plus 2 wires separately run from power supply. KC-1GRD ~ door 50m(0.65mma) 100m(1.0mma) KC-1GRD ~ farthest sub 50m(0.65mma) 100m(1.0mma) KC-1GRD ~ IER-2 50m(0.65mma) 100m(1.0mma) Image view area KC-DAR ★ 124cm ★ 235cm 130cm 50cm ★ 111cm 60cm★ 50cm * approximate 14 Video Sentry Color Tilt Features DOOR ROOM 3 5 KB-3MRD • • • • • Door station 3 doors & 5 monitors w/TILT camera control. INSTANT ON audio & image of door. Selective calling or All Call. Audio sub station in lieu of monitor. Optional audio door at 3rd entry. Master station COLOR VIDEO ENTRY SECURITY KB-DAR Video door station 2 2 2 PT 2 IER-2 2 KB-DAR Video door station Call extension m P.104 2 KB-3MRD Master station 2 or PS24 KB-DAR Video door station IF-DA Audio door station Power supply PS-2420S PS-2420UL PS-2420 m P.107 Communication network Wiring 200m / 1.0mma KB-DAR KB-DAR KB-3HRD 4-tone chime Tilt camera control M KB-DAR IER-2 KB-3HRD 2 NP 2 KB-3MRD (1) 2-tone chime Tilt camera control KB-3HRD KB-3MRD 2 KB-3HRD4 2 2 2 2 2 KB-3SD KB-3HRD 2 2 M H KB-DAR 2 A1 A2 KB-3SD IF-DA 2A1 + 2A2 A1 A2 Electric door strike Cable Cable specified for wiring to both door and inside stations l 0.65mma to 1.2mma dia. l PE(polyethylene) insulation & vinyl jacketed cable l Attenuation: less than -6.5dB at 10MHz./100m length. l Solid copper conductor. l Line impedance: c75 ohm (less than 100 ohm at the highest). 3A1 3A2 B 1A1 B1 1A2 B2 N N 2 A B 1A1 B1 1A2 B2 A B 1A1 B1 1A2 B2 A + + - + - N S S 1 E or A H B 1A1 B1 1A2 B2 + - D1 E1 (1) Selective Call or All Call type voice calling (from any). Communication on handsets individually. 2 KB-3SD 1A1 B1 1A2 B2 A1 A2 2 NN N A 8-tone chime Tilt camera control 15 100m / 1.0mma b1 b2 b3 E B A1 B1 A2 B2 (1) l D1, E1 : for IF-DA door station instead of third KB-DAR. l Run audio/video wires in a separate jacketed cable from door release wires. N : PS-2420S, PS-2420UL H : AC transformer (1) External light control • • • • Push chime or receiver volume control. Optional selective door release with RY-3DL. Hands-free monitoring audio & image of door. Video door station's white LED illumination automatically turns on in the darkness. Lineup Sub station KB-3HRD KB-3HRD KB-3HRD Sub master station Sub master station Sub master station Sub master station 2 2 2 KC-32EU RY-3DL Picture memory unit m P.17 Door release adaptor m P.18 KA-DGR PANEL Electric door strike (locally available) or 2 2 KB-3SD 2 Stainless steel housing for KB-DAR COLOR VIDEO ENTRY SECURITY KB-3HRD Audio sub station max. 2pcs 2 PS24 2 PS24 Unit dimensions 83.5 195 83.5 140 Power source Consumption 44 KB-3SD 185 86 Power supply Video monitor Scanning lines Communication 83.5 120 210 83.5 IER-2 29 88 100 Image view area 74 KAW-D Night viewing 151 142 KA-DGR PANEL 107 42 109 MAW-B 30k angled box m P.18 Auxiliary light control relay m P.105 Specifications (KB-3MRD) KB-3MRD, KB-3HRD KB-DAR 105 KAW-D 105 83.5 4.5 30˚ 55.4 Distance Image view area KB-DAR Door release Wiring 24V DC. KB-3MRD: max.710mA. 230mA standby. KB-3HRD: max. 260mA. 80mA standby. KB-3SD: max 85mA. 50mA standby. PS-2420S, PS-2420UL 4 inch TFT color LCD 525 lines Door calls in w/4-tone chime, 30 sec. Hear and see door instantly. Pick up at any station to reply, 2-1/2 min. timed. Recycle with MONITOR. Monitor audio& image of door hands-free w/MONITOR. Press a station selector and call by voice. The called station replies hands-free. Lifting handset, press ALL CALL button to call the other stations w/pretone and voice. Approx. 60cm Horiz., 111~235cm Vert. at 130cm high & at 50cm in front of camera. Up to 30cm from camera, with white LED projected. Background scene beyond 30cm cannot be seen. Contact rating: 12V AC, 400mA 2 parallel wires to door, non-polarized. 2 wires in loop between monitors, plus 2 wires separately run from power supply. KB-3MRD ~ door 100m(0.65mma) 200m(1.0mma) KB-3MRD ~ farthest sub 50m(0.65mma) 100m(1.0mma) KB-3MRD ~ IER-2 50m(0.65mma) 100m(1.0mma) ★ 124cm ★ 235cm 130cm 50cm ★ 111cm 60cm★ 50cm * approximate 16 Color Video Accessories Picture memory unit Features l Easy add-on to present or new system, color or black & white l 4 pictures in 1 frame (16 frames), 16, 32 or 60 individual picture save mode l Max. 8 pictures stored in memory Used for KC-32EU Picture memory unit Programming l Date / time position l Date / time l Save mode Functions l Auto Picture save l Manual picture save (when viewing) l Absence set l Replay l Store in memory l Erase one or all pictures Unit dimensions KC-32EU 195 COLOR VIDEO ENTRY SECURITY KC-1MRD, KC-1GRD, KB-3MRD MK-1GD, MK-2MCD 83.5 80 54.5 Single-gang mounting Wiring IER-2 KC-DAR KC-32EU KC-1GRD 2 2 KC-1GRD KC-32EU Master station Picture memory unit 2 M N H 2 2 2 2 N A A1 A2 NP A1 A2 B1 B2 KC-1HRD KC-1HRD 2 NP 1A1 B1 1A2 B2 N B 1A1 B1 1A2 B2 A NP N IER-2 Electric door strike S S 1 E N : PS-2410DIN, PS-2420DIN, PS-2420S H : AC transformer Press REC button to view each 4-frame picture individually. Specifications (KC-32EU) Power source Power supply Channel Wiring Wiring distance MK-1GD KC-32EU Master station Picture memory unit 17 B 1A1 B1 1A2 B2 18V DC, 230mA. 24V DC, 160mA. PS-1820S, PS-1820UL, PS-2420S, PS-2420UL One video door per unit 2 parallel wires to door (NP). 2 wires to Master (Polarized). KC-32EU to door 50m(0.65mma) 100m(1.0mma) KC-32EU to master 25m(0.65mma) 5m(1.0mma) KC-32EU to Power supply 10m(1.0mma) (20m w/1.2mma) Long distance adaptor Features Wiring 250m / 1.2mma JF-DV Long distance adaptor A1 B1 A2 B2 + – A1 A2 A1 A2 + – C Cable KC-1MRD, KC-1GRD KC-32EUKC-1ARD/KC-1GRD JA-2MECD, JA-2MCD JB-2MD, JB-2MED JF-1MD, JF-2MED 1.0mma to 1.2mma. Solid copper conductor PE insulation (not PVC). Specifications Power source 18VDC, 24VDC PS-1820S, PS-1820UL, PS-2420S, PS-2420UL of system or separate 120mA. 2 parallel wires to ea. door & master. JA, JB, KC door~JBW-BA 100m~300m(1.2mma) JBW-BA~JA, JB, KC master 50m(1.2mma) JF door~JBW-BA 100m~250m(1.2mma) JBW-BA~JF master/JF-1FD/JF-1SD 50m(1.2mma) JBW-BA~PS 50m(1.2mma) Unit dimensions Current consumption Wiring Distance 108.5 JBW-BA 61 122.5 JF-2MED JBW-BA Used for JBW-BA 50m / 1.2mma COLOR VIDEO ENTRY SECURITY l When JA, JB, KC color video door station is more than 100m to max. 350m away, or JF color video door station is more than 100m to max. 300m away. l One required for each door station. Selective door release adaptor Wiring Features l Selective door release with one button l Door release contacts release the door where communication is established. l Normally open contacts for electric strike. Normally closed contacts to work with magnetic locks. Electric door strike Electric door strike L2 C2 L2 Electric door strike Door release adaptor KB-3MRD CN12 GR BL PL CN11 OG YL b1 b2 b3 L D1 E D2 L3 C3 L3 Used for RY-3DL RY-3DL L1 C1 L1 N H KB-3MRD, JB-2MED, JB-2MD MK-2MCD, IE-2AD(U) JF-2MED GR : Green BL : Blue PL : Purple OG : Orange YL : Yellow H : AC transformer N : PS2420S, PS-2420UL Unit dimensions Specifications Power source Power supply Relay contacts 140 RY-3DL Wiring distance 74 42 12~24V DC, 30mA. 12~16V AC, 60mA. PS-2420S, PS-2420UL; PS-1820S, PS-1820UL; PS-1225S/UL; AC trans. Normally open output. 1A at 50V AC. 1A at 30V DC (for other types, use matching relay) Master to RY-3DL 50m(0.65mma) 100m(1.0mma) RY-3DL to Electric door strike 50m(0.65mma) 100m(1.0mma) 30kangle box Features Image view area l 30k Angle Box for mounting video door station to position door camera to view visitors better. l Designed for 1-gang surface mounting. KAW-D 30 Used for KC-DAR, KB-DAR, MK-DH m 50c Unit dimensions KC-DAR ★ m 60c 142 KAW-D KAW-D 83.5 *Figure is approximate. 30k angled box 107 105 4.5 55.4 30˚ Desk-top stand Used for MCW-S Monitor desk stand MK-1GD, MK-1HD MK-2MCD, MK-2HCD KC, KB monitors 18 Wide Angle Video Sentry DOOR ROOM 1 Features 3 MK-1GD • • • • Door station Single-door, three-monitor system with door release Instant voice call-in with image Internal handset communication. All call type voice calling Transfer of door call-in. (Image of caller remains on) Master station 2 4 2 IER-2 2 Call extension m P.104 BLACK & WHITE VIDEO ENTRY SECURITY PT MK-DV PS18 Video door station or MK-1GD Master station or MK-DH MK-DVF Video door station Video door station Power supply PS-1820S PS-1820UL PS-1820 m P.107 Communication network Wiring 200m / 1.0mma MK-DV MK-1HD M H 4-tone chime A1 A2 NP MK-2SD MK-1HD Electric door strike Instant voice calling w/image. All call with pre-tone/voice. Internal communication on handsets 4 4 MK-1GD M MK-1HD MK-1HD 2 2 MK-2SD MK-DV 75m / 1.0mma IER-2 MK-1GD H 2 U DOOR SUB B1 A1 A2 B2 NP CALL EXT IER-2 1 S E S RLSE. DC18V + L L P U SUB IN OUT B1 B1 B2 B2 NP DC18V IN OUT + + DC18V IN OUT + + P SW1 OFF ON MK-2SD 4 SUB SUB B1 B2 DC18V + SW1 OFF l MK-2SD may be wired in the same manner as MK-1HD. U : PS-1820S, PS-1820UL H : AC transformer SW1-ON Terminated 19 SW1 MK-2SD 4 NP P SUB IN OUT B1 B1 B2 B2 NP P B1 B2 DC18V + SW1 ON • Fixed camera, wide angle viewing • Infrared LED's projected on callers at 50cm in the darkness Lineup Sub station 4 MK-2DA MK-2DG Two-call video door station m P.25 or MK-1HD Sub master station Sub master station 2 2 MK-2SD MK-2SD Audio sub master station Audio sub master station Electric door strike (locally available) KAW-D KC-32EU MKW-P Picture memory unit m P.25 MK-DV Gang box mounting plate 30k angled box m P.18 Boxed sets MKS-1GD: MK-1GD & MK-DH MKS-1GDV: MK-1GD & MK-DV MKS-1GDVF: MK-1GD & MK-DVF Add appropriate power supply BLACK & WHITE VIDEO ENTRY SECURITY or MK-1HD Two-call video door station m P.25 Image view area Unit dimensions MK-1GD, MK-1HD • MK-DH, MK-DV & MK-DVF 205cm 185cm (2) (1) 65cm 65cm MK-2SD 200 210 MK-2SD 60/ 83.5 60/ 83.5 150cm 140cm 120cm 50cm 50cm (1) Initial horizontal view 69 215 89 95cm (2) When the camera is turned up (MK-DH only) 61 Specifications MK-DV Power sourse Consumption 209 173 MK-DVF 98 (1) 27 45 135 5.5 120 130 83.5 98 35 83.5 IER-2 MK-DH 88 Power supply Calling Communicarion 29 Video monitor Scanning lines Minimum illumination Door release Wiring Distance DC 18V MK-1GD : (Max.) 650mA. MK-1HD : (Max.) 450mA. MK-2SD : (Max.) 150mA. PS-1820S, PS-1820UL Chime, audio & image, approx. 45 sec. Simultaneous with handsets, approx. 2-1/2 min. Extend w/MONITOR. All call type voice calling, common talk. 4 inch direct view flat CRT 525 lines 1 Lux or less at 30cm distance AC 12V, 0.4A dry-closure contact(L, L). 2 conductors to door. 4 conductors betweens room stations Door to MK-1GD 200m(1.0mma) MK-1GD to farthest sub 75m(1.0mma) MK-1GD to PS18 10m(1.0mma) 20 PanTilt Video Sentry DOOR ROOM 2 Features 3 MK-2MCD Door station • • • • Two-PanTilt door, three-monitor system with door release Instant voice call-in with image Internal handset communication. All call type voice calling Transfer of door call-in. Image of a caller stays on Master station 4 2 2 IER-2 2 Call extension m P.104 PT 2 BLACK & WHITE VIDEO ENTRY SECURITY MK-DBC PS18 Video door station MK-2MCD Master station or or MK-DGC Video door station MK-DAC MK-DH Video door station Video door station Fixed camera Power supply PS-1820S PS-1820UL PS-1820 m P.107 Communication network Wiring 100m / 1.0mma 75m / 1.0mma MK-2HCD MK-DBC MK-2SD 4-tone chime MK-DBC MK-DGC MK-2MCD 2 2 PanTilt control MK-D MK-DBC 2-tone chime H MK-DGC MK-2SD 1 2 MK-D M NP A1 A2 MK-DGC IER-2 MK-2MCD 2 A1 A2 NP MK-D NP M MK-2HCD Instant voice calling w/image. Pan/tilt camera from any inside monitor station. All call initiated w/pre-tone/voice. Internal communication on handsets. Electric door strike H MK-2HCD MK-2HCD 4 4 2 U DOOR1 SUB 1A1 B1 1A2 B2 NP CALL DOOR2 EXT IER-2 1 2A1 S E S 2A2 SUB SUB IN OUT IN OUT B1 B1 B2 B2 NP DC18V RLSE. DC18V + L L DC18V IN OUT U P IN OUT + + SW1 + P P l MK-2SD may be wired in the same manner as MK-2HCD. U : PS-1820S, PS-1820UL H : AC transformer SW1-ON : Terminated 21 SW1 MK-2SD MK-2SD NP + ON OFF 4 B1 B1 B2 B2 4 SUB B1 B2 DC18V + – SW1 OFF NP P SUB B1 B2 DC18V + – SW1 ON • Optional audio door station at second entrance • Infrared LED's projected on callers at 50cm in the darkness Lineup Sub station 4 KC-32EU Picture memory unit m P.25 Sub master station 4 4 MK-2SD MK-2SD Audio sub station Audio sub station RY-3DL MKW-R KAW-D Surface mount box for MK-DBC 30kangled box m P.18 Door release adaptor m P.26 MK-DAC, MK-DGC & MK-DBC 220cm 180cm 90cm 65cm 50cm 130cm 45cm 90cm 180cm Unit dimensions 50cm MK-DGC 92 210 Power sourse Consumption 114 12.5 19 37 215 89 69 MK-DBC MK-DH 130 83.5 130 92 172 Power supply Calling Communicarion 63 MK-DAC 44 98 83.5 98 47.5 35 12.5 19 37 RY-3DL 88 29 74 Video monitor Scanning lines Minimum illumination Door release Wiring Distance 140 83.5 28 83.5 120 130 IER-2 Max. pan-and-tilt view area: 90cm Vert., 180cm Horiz. (approx.) Specifications 170 MK-2SD 200 MK-2MCD, MK-2HCD 98 Electric door strike (locally available) Image view area Wiring Electric door strike Selective door release & OPTION feature button MK-2MCD RY-3DL 2 When the system needs to control 6 two door releases selectively, install the RY-3DL adaptor.The OPTION 2 button may be used, for example, to H turn the porch light, etc. For wiring, U 6-pin connector is available as an Electric door strike accessory. It plugs into the socket on back of MK-2MCD unit, providing control outputs for Door Release and Option feature. 115 MK-D in Europe or MK-2HCD Sub master station Audio door station *Not available BLACK & WHITE VIDEO ENTRY SECURITY or MK-2HCD MK-D* DC 18V MK-2MCD: (Max.) 750mA. MK-2HCD: (Max.) 450mA. MK-2SD: (Max.) 70mA. PS-1820S, PS-1820UL Chime, audio & image, approx. 45 sec. Simultaneous with handsets, approx. 2-1/2 min. Extend w/MONITOR. All call type voice calling, common talk. 4 inch direct view flat CRT 525 lines 1 Lux or less at 30cm distance AC 12V, 0.4A dry-closure contact(L, L). 2 conductors to door. 4 conductors between inside stations Door to MK-2MCD 100m(1.0mma) MK-2MCD to farthest sub 75m(1.0mma) MK-2MCD to PS18 10m(1.0mma) 42 22 PanTilt Video Sentry DOOR ROOM 1 6 *Not available in Europe Scheduled to stop production MY-CU & IE-8MD Door station Master station Features • • • • • 6 monitors & single PanTilt door Additional audio door station Add-on monitors with additional power supply Answer door from any room station Selective calling or All Call between room stations Lineup Sub station 6 2 IE-8HD 4 Electric door strike (locally available) 6-call sub master MYH-CU Sub video-monitor MK-DBC Video door station 5 PS18 IE-8MD BLACK & WHITE VIDEO ENTRY SECURITY IE-8HD MYH-CU MY-CU Main video monitor 2 PS18 6 MYW-BA Long distance adaptor m P.26 4 IF-DA Door station IE-8HD MYH-CU RY-AC/A 4 6 External signaling relay m P.104 IE-8HD MYH-CU 6 4 Power supply PS-1820S PS-1820UL PS-1820 m P.107 IE-8MD & MY-CU TAR-3 External signaling relay m P.105 IE-8HD MYH-CU Communication network Wiring 100m / 1.0mma 75m / 1.0mma IE-8HD IE-8HD IE-8MD & MY-CU MK-DBC MK-DBC 2 2 M M M IF-DA IF-DA A1 A2 M IE-8HD / MYH-CU IE-8HD U 210 IE-8MD & MY-CU IE-8HD & MYH-CU 110 155 Specifications (MY-CU & IE-8MD) Power source Power supply Communication Wiring Distance 83.5 Unit dimensions 79 Electric door strike 6 6 6 4 4 4 4 4 MYH-CU 1 MYH-CU 2 3 4 5 1A1 B1 1A2 B2 U1 U2 1A1 B1 1A2 B2 U1 U2 1A1 B1 1A2 B2 U1 U2 1A1 B1 1A2 B2 U1 U2 1A1 B1 1A2 B2 U1 U2 1A1 B1 1A2 B2 U1 U2 + – + + + + – + – ON (OFF) OFF OFF OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 – D1 D2 E Electric door strike IE-8HD & MYH-CU5 6 5 MY-CU IE-8HD 4 & 2-tone chime. Pan and tilt camera on any monitor. Selective call or All call on inside stations. 23 4 6-call master + – D1 E1 D2 E2 EL EL SL SL 1 2 3 4 1 2 – – U 1 2 3 4 1 2 3 4 H l Use a power supply for additional monitors MYH-CUs. l Run audio/video wires in a separate jacketed cable from door release wires. U : PS-1820S, PS-1820UL H : AC transformer 18V DC, 1.8A, IE-8MD: 12~18V DC, 0.5A. MY-CU: 18V DC, 0.9A. MYH-CU: 18V DC, 0.4A. PS-1820S, PS-1820UL Door calls in w/4 or 2-tone chime, 45 sec. Lift any handset to reply, 2-1/2 min. Press MONITOR to reactivate. Cut chime tone if needed. 2 parallel wires to door, non-polarized. 6 wires, monitors in loop. MY-CU to P/T door 50m(0.65mma) 100m(1.0mma), MY-CU to MYH-CU1 35m(0.65mma) 75m(1.0mma) Master Sentry DOOR Features ROOM 3 8 LEF-C Video Door station Scheduled to stop production *Not available in Europe Adaptor • • • • • • Semi-flush residential communication system One to three PanTilt video doors Door release activation All Call and music distribution through stations Audio door & room sub stations for varied systems Any combination of doors and rooms up to 11 total stations Master station 2 Lineup 6 2 5 common 2/door 2 LEF-5C LE-C 5-call master m P.67 Sub station m P.69 MK-DGC LE-CN Video door station Privacy sub (Photo) m P.69 PS18 MYW-P3L PS12 MYH-CUB 3 PanTilt door adaptor LE-B Semiflush video-monitor 10-call master 3-call master m P.67 5 common 2/door 1/station MK-DBC LE-BN Privacy sub m P.69 6 MYW-P1L Video door station Sub station m P.69 LEF-3C LEF-1C 1 PanTilt door adaptor All call sub master m P.69 MYH-CUB Electric door strike (locally available) Semiflush video-monitor LEF-10C BG-10C RY-PA 10-call master MK-DAC Door release relay All call, chime & music adaptor m P.69 LE-D LE-DA Sub station m P.69 Sub station m P.69 Video door station Power supply PS-1820S PS-1820UL PS-1820 m P.107 PS-1225S PS-1225UL PS-1225 m P.106 Communication network MK-DGC Chime tone & LED. 1. Wiring MK-DGC MYH-CUB &LEF-10C LEF-10C MYH-CUB/ LEF-10C MYW-P3L (ea.) 2 6 NP MK-DGC All call or selective call Varies A1 A2 1A1 1A2 B1 B2 A1 A2 2A1 2A2 U1 U2 + – A1 A2 3A1 3A2 2. MYH-CUB &LEF-10C MK-DGC Door 1 only w/MYW-P1L (RY-PA req’d for door release) Doors 1~3 w/MYW-P3L & selective door release. (RY-PA’s req’d for door release) Unit dimensions PT MYH-CUB 20 200 240 200 238 200 110 150 15.5 20 40 U1 U2 + – U1 U2 + – C 2 3 4 5 6 7 8 9 10 E R Y + – 1 C 3 4 5 6 7 8 9 10 E R Y + – L K8 K9 K10 L K8 K9 K10 (*1) + – PS12 (*2) (*1)Add’l video monitors with another PS-1820 power supply (*2)Intercom wiring varies by system. Power source Power supply Communication Wiring 43 RY B1 B2 Q : RY-PA H : AC transformer U : PS-1820S/UL T : PS-1225S/UL (2.5A) 83.5 230 155 LB LC A1 A2 Specifications (LEF-C) 33.5 40 MYW-P3L RY DC DB DA E R EL2 KC KB KA 20 LEF-5C/10C LA B1 B2 PS18 3. RY 23 A1 A2 LEF-10C Electric door strike MYH-CUB/ LEF-10C 6 11 PanTilt viewing. BLACK & WHITE VIDEO ENTRY SECURITY LEF-10C Distance 12V DC, 300mA per station. PS-1225S or PS-1225UL power supply. Momentary tone & 20 sec. LED. Depress a station button and press Talk/Listen button. Station LED and occupied LED remain lit while in use. Single talk channel. 9 common + total No. of stations in system (for all features except K terminal options) Between farthest stations 200m(0.65mma)300m(0.8mma) 24 B&W Video Accessories Dual-call door station Features MK-2DA Two-call video door station Wiring Call two monitors (MK-1GD) selectively. Each monitor is powered by a separate power supply. l Wide-angle view l Camera angle adjuster (16k upward) l Backlit call buttons l Acrylic nameplates for engraving l While one monitor is in use, the other monitor is not operational. 4 2 4 M 2 MK-2DA 1A1 1A2 PT MK-1GD A1 A2 L L P. L L MK-2DA + – B1 B2 P. B1 B2 NP ON U + – P. B1 B2 SW1 MK-2SD + – B1 B2 SW1 ON NP 189 Electric door strike U : PS-1820S, PS-1820UL H : AC transformer Specifications 35 119 Power source Camera Scanning lines Minimum illumination Image view area Wiring Wiring distance MK-2DG MK-2DG Two-call video door station 206 BLACK & WHITE VIDEO ENTRY SECURITY A1 A2 P. MK-2SD U + – MK-1GD 2A1 2A2 Unit dimensions MK-2SD MK-1GD MK-2DA MK-2DG PANEL Panel only 120 34 Supplied by monitor in use CCD camera w/infrared LED’s 525 lines 1 Lux at 50cm from camera 70cm Vert. x 110cm Horiz. at 50cm 2 parallel wires, polarized Door to monitor 50m(0.65mma) 100m(1.0mma) Picture memory unit Features Wiring l Easy add-on to present or new system, color or black & white l 4 pictures in 1 frame (16 frames), 16, 32 or 60 individual picture save mode l Max. 8 pictures stored in memory Used for KC-32EU MK-DV V KC-32EU MK-DV KC-1MRD, KC-1GRD, KB-3MRD MK-1GD, MK-2MCD MK-1GD 2 2 A1 A2 NP A1 A2 B1 B2 1A1 B1 1A2 B2 V Unit dimensions KC-32EU 195 S S 83.5 V : PS-1820S, PS-1820UL H : AC transformer KC-32EU 80 54.5 Picture memory unit Single-gang mounting Specifications (KC-32EU) Power source Power supply Channel Wiring Wiring distance 25 18V DC, 230mA. 24V DC, 160mA. PS-1820S, PS-1820UL One video door per unit 2 parallel wires to door (NP). 2 wires to Master (Polarized). KC-32EU to door 50m(0.65mma) 100m(1.0mma) KC-32EU to master 25m(0.65mma) 5m(1.0mma) KC-32EU to Power supply 10m(1.0mma) (20m w/1.2mma) Long distance adaptor Features Wiring l When PanTilt door is more than 100m to max. 300m away. l Separate power supply allows mounting MYW-BA up to 50m away from master station or adaptor. MK-DV MYW-BA MK-1GD A1 B1 A2 B2 A1 A2 + – A1 A2 + – U Used for Cable Unit dimensions Specifications Impedance: 90d. Permitted closed loop DC resistance: 9.9d or less. PE insulation (not PVC). Power source Current consumption Wiring Distance MYW-BA 190 Long distance adaptor PS-1820S/UL of system or separate 250mA. 1mA standby. 2 parallel wires to ea. door & master. MYW-BA~door 200m(1.0mma) 300m(1.2mma) MYW-BA~master 50m(1.0 or 1.2mma) MYW-BA~PS 7m(1.0mma) 10m(1.2mma) 42 80 Selective door release adaptor Features Wiring l Selective door release with one button l Door release contacts release the door where communication is established. l Normally open contacts for electric strike. Normally closed contacts to work with magnetic locks. Electric door strike Electric door strike L2 C2 L2 RY-3DL Door release adaptor Unit dimensions V Specifications Relay contacts 140 b1 b2 b3 L D1 E D2 H Wiring distance 74 CN12 GR BL PL CN11 OG YL GR : Green BL : Blue PL : Purple OG : Orange YL : Yellow H : AC transformer V : PS-1820S, PS-1820UL Power source Power supply RY-3DL MK-2MCD L3 C3 L3 Used for MK-2MCD, IE-2AD(U), KB-3MRD JB-2MD, JB-2MED JF-2MED RY-3DL L1 C1 L1 BLACK & WHITE VIDEO ENTRY SECURITY MYW-BA MK-1GD, MK-2MCD MY-CU w/IE-8MD or TD-H/B MYW-P1L or MYW-P3L w/LEF LEF-C TB-ADM10 w/TC-M 42 12~24V DC, 30mA. 12~16V AC, 60mA. PS-1820S, PS-1820UL; PS-2420S, PS-2420UL; PS-1225S, PS-1225UL; AC trans. Normally open output. 1A at 50V AC. 1A at 30V DC (for other types, use matching relay) Master to RY-3DL 50m(0.65mma) 100m(1.0mma) RY-3DL to Electric door strike 50m(0.65mma) 100m(1.0mma) Call extension Features Unit dimensions l Announces (chime) call tone only, adjustable l Indoor mounting IER-2 Call extension 88 83.5 IE series, MK-1GD, MK-2MCD, KC-1MRD KC-1GRD, KB-3MRD, NEM-n, NEM-nA, TC-M JB-2MD, JB-2MED, JA-2MECD, JA-2MCD JF-1MD, JF-2MED 120 Used for 29 26 Two-Wire Electric Lock Door Phone DOOR ROOM 1 1 DA-1AS Lineup Boxed set DA-1AS DA-1AG Kit box (silver color) Kit box (gray color) Electric door strike (locally available) DAR-1 Call extension Door station silver panel DA-1MD Master station DA-1MD Door station gray panel Master station DAW-P AUDIO ENTRY SECURITY *Add an appropriate power supply. Door station mounting plate (83.5mm) *Add an appropriate power supply. Power supply PT-1211D PT-1211C m P.106 Features Wiring l Two-wire system including door release l Door release wired to door station, requiring no power transformer l User-optional function button (modification required) l Call tone MUTE with indicator l Call extension sounder 310m / 1.0mma 155m / 1.0mma DA-1MD DA-1DS DA-1DG M 2 DAR-1 2 NP 2 2 P Communication network PT-1211D/C (1) Electric door strike DA-1DS, DA-1DG DA-1MD DAR-1 (2) L L ~ ~ D E D E PT-1211D/ PT-1211C S SE SW SW M Unit dimensions DA-1MD 89 22 200 175 100 61 Specifications (DA-1AS, G) Power source Power supply Communication Wiring Distance 27 (3) l Place PT-1211D/C inside electrical enclosure and connect to breaker, less than 16V. l Do not use PT-1211D/C for any other equipment. l Terminals SW, SW; Dry-closure contact AC 18V, 40mA to connect user-optional function (Gate, Light, Garage, Proximity Access Control, etc.) (1) External device Relay/Controller (2) Door release (AC 16V, 20d or more) (3) User-optional function (AC18V, 40mA) Hold down gCALLh button to ring inside station. DA-1DS, DA-1DG S SE AC 15V. PT-1211D, PT-1211C Press and hold down Button to call. 2 wires, throughout system: PS - Master - Door - Door rlse. PT-1211D/C ~ Door rlse. 110m(0.6mma) 200m(0.8mma) 310m(1.0mma) PT-1211D/C ~ DA-1MD 55m(0.6mma) 100m(0.8mma) 155m(1.0mma) Chime Tone Intercom DOOR ROOM 1 1 C-123L/A Door station Master station Lineup Electric door strike (locally available) C-D Door station C-ML/A Master station Boxed set C-123L/A Chime-Com boxed set AUDIO ENTRY SECURITY Power supply PS-0602D PS-0602C or Batteries m P.106 Features Wiring l Open voice door answering with door release control l Adjustable communication volume l Automatically turns off l Battery or DC power supply 115m / 0.8mma C-ML/A C-D 2 NP M Communication network 1 E + – 1 E Electric door strike W L L H C-ML/A C-D H : AC transformer W : PS-0602D, PS-0602C M Specifications (C-123L/A) Power source Power supply Communication Unit dimensions C-D C-ML/A Wiring 88 83.5 190 120 83.5 Distance 6V DC, 85mA PS-0602D, PS-0602C or Batteries gCh(SUM-2) x 4 pcs. Door calls in w/2-tone chime, not adjustable. Press TALK button to reply, release to listen. Power automatically shuts off circuit. 2 parallel wires to door, non-polarized (+ 2 for Electric door strike). Master to door 75m(0.65mma) 115m(0.8mma) 29 130 44 28 Chime Tone Intercom DOOR ROOM 1 1 TCS-MH Door station Master station TC-DC Door station Boxed set TCS-MH Chime-Phone set AUDIO ENTRY SECURITY TC-MH Master station Features Wiring l Chime-phone intercom set, battery-operated l Adjustable chime volume l Battery status indicator 230m / 0.8mma TC-MH TC-DC 2 P. Communication network 1 2 1 2 R TC-MH TC-DC R : Batteries P. Polarized Specifications (TCS-MH) Power source Power supply Communication Unit dimensions 28 80 29 83.5 210 130 98 Wiring Distance TC-MH 83.5 TC-DC 58 6V DC, 70mA Batteries gAAh(SUM-3) x 4 pcs Door calls in w/2-tone chime, adjustable. Pick up to reply. 2 parallel wires, polarized. TC-MH to door 150m(0.65mma) 230m(0.8mma) Chime Tone Intercom DOOR ROOM 1 IE-1AD(U) 1 Door station Master station Lineup Electric door strike (locally available) IF-DA Door station m P.34 IER-2 Call extension m P.104 TAR-3 IE-1AD(U) 12~24V DC power supply 12~16V AC transformer Master station Features External signaling relay m P.105 Wiring l Chime tone intercom for 2 locations l Door release button l AC or DC power source 360m / 1.0mma IE-1AD(U) IF-DA IER-2 2 NP 2 M 1 2 1 2 Communication network 2 Electric door strike H WH AUDIO ENTRY SECURITY Power supply 1 E L L + – IE-1AD(U) IF-DA IER-2 l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer WH : White(2) M Specifications (IE-1AD(U)) Power source Power supply Communication Unit dimensions IF-DA 130 IE-1AD(U) 98 Door release Wiring 210 83.5 83.5 Distance 12~16V AC, 180mA. 12~24V DC, 160mA. AC transformer (for IE & Electric door strike), PS-1225S/UL. Door calls in w/4-tone chime, adjustable. Pick up handset to reply. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized (+2 for Electric door strike) IE-1AD(U) to door 150m(0.65mma) 360m(1.0mma) 28 80 58 30 Chime Tone Intercom DOOR ROOM 3 IE-1GD(U) 1 Door station Master station Sub station Lineup Electric door strike (locally available) IE-JA Door station m P.34 IER-2 Call extension m P.104 AUDIO ENTRY SECURITY Power supply IE-1GD(U) IEH-1CD Master station Sub master station TAR-3 External signaling relay m P.105 12~24V DC power supply or 12~16V AC transformer Features Wiring l 3-station chime tone intercom with one door l Door release button l All call type room calling l Chime tone cutout at sub station l AC or DC power source 360m / 1.0mma 190m / 1.0mma IE-1GD(U) IEH-1CD IEH-1CD IER-2 IE-JA 2 M Communication network 1 2 IEH-1CD 2 2 D1 E1 IER-2 IE-JA IE-1GD(U) Electric door strike M 6 6 H T R C E T R C E T R C E L L L L L L 1 E + – IEH-1CD l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer All Call type calling with pretone & voice Specifications (IE-1GD(U)) Unit dimensions Power source IE-1GD(U) IEH-1CD 115 IE-JA 116 Communication 210 83.5 83.5 Door release Wiring 10 100 31 Power supply 61 Distance 12~16V AC, 200mA. 12~24V DC, 200mA. AC transformer 12~16V, 550mA (for both IE & Electric door strike), PS-1225S/UL Door calls in w/4-tone chime to all stations. Chime can be cut out at sub(s). Pick up any station to reply. Press CALL to call other inside stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires to door, non-polarized. 6 wires in loop, between rooms. IE-1GD(U) to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma) Chime Tone Intercom DOOR ROOM 3 IE-2A2D(U) 2 Door station Master station Sub station Lineup Electric door strike (locally available) IE-JA Door station m P.34 IER-2 Call extension m P.104 IF-DA Door station m P.34 IE-2AD(U) IEH-1CD Master station, 2 door releases Master station Sub master station TAR-3 IEH-1C2D External signaling relay m P.105 12~24V DC power supply 12~16V AC transformer 2 door release Features Wiring l 3-station chime tone intercom l 2 door stations w/door release l All call type room calling l Chime tone cutout at sub station l Door selective monitoring at master station l AC or DC power source 360m / 1.0mma 190m / 1.0mma IE-2A2D(U) IE-JA 2 M IEH-1C2D 8 IER-2 2 2 M2 1 2 IER-2 IE-JA 8 IEH-1C2D 2 IF-DA 1 2 Communication network IEH-1C2D Electric door strike 1 IE-2A2D(U) Electric door strike 2 H D1 E1 D2 E2 T R C E T R C E T R C E L L L L L L BL BL + – BL AUDIO ENTRY SECURITY Power supply IE-2A2D(U) 1 E IF-DA BL : Blue(2) IEH-1C2D ( 1) All call type voice calling between rooms (*1) Available in IE-2A2D(U) or IE-2AD(U) w/RY-3DL Specifications (IE-2A2D(U)) Power source Unit dimensions Power supply IE-JA 115 IE-2A2D(U), IE-2AD(U) Communication 83.5 10 210 83.5 83.5 210 116 IEH-1CD 130 IF-DA 98 H : AC transformer 83.5 28 Door release Wiring 100 68 100 61 Distance 12~16V AC, 200mA. 12~24V DC, 200mA. AC transformer 12~16V AC, 550mA (for both IE & Electric door strike). PS-1225S/UL Door calls in w/4- or 2-tone chime to all stations, 45 sec. Chime can be cut out at sub. Pick up any station handset to reply. Press CALL to call other stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized. 6 wires in loop, rooms. IE-2A2D(U) to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma) 32 Chime Tone Intercom DOOR ROOM 2 6 IE-8MD Door station Master station Lineup Sub station Electric door strike (locally available) IE-JA Door station m P.34 TAR-3 External signaling relay m P.105 IF-DA Door station m P.34 AUDIO ENTRY SECURITY Power supply PS-1225S PS-1225UL PS-1820S PS-1820UL IE-8MD IE-8HD 6-call master 6-call sub master RY-AC/A External signaling relay m P.104 PS-1225 m P.106 PS-1820 m P.107 Features Wiring l Expandable to 6-station system l Selective or All Call between inside stations l Door select and monitor button (on IE-8MD only) l AC or DC power source l Selective door release control l Chime tone cutout on inside stations, selectable 360m / 1.0mma IF-DA M IE-8MD IE-8HD IE-8HD IE-8HD IE-8HD IE-8HD 2 IE-8HD IE-8MD 1 M 1 2 IE-8HD 2 4 IE-JA 2 Communication network IF-DA 190m / 1.0mma 1 2 3 M Electric door strike IE-JA Electric door strike H M 4 IE-8HD 5 IE-8HD T 6 IE-8HD 4 4 4 4 1 D1 E1 D2 E2 EL EL SL SL 1 2 3 4 + – 2 1 2 3 4 station # setting 2 4 5 6 3 1 2 3 4 4 1 2 3 4 5 1 2 3 4 6 1 2 3 4 3 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 H : AC transformer T : PS-1225S/UL U : PS-1820S/UL or AC transformer Internal communication by Selective Call or All Call. Chime tone can be muted at each station selectively. Specifications (IE-8MD) Power source Unit dimensions IF-DA Power supply 130 IE-8MD IE-8HD 210 83.5 83.5 98 Communication 28 IE-JA 115 110 116 33 83.5 10 79 Door release Wiring Distance 12~16V AC, 900mA. 12~18V DC, 500mA Intercom only; DC 12V or 18V power supply. AC transformer 12V AC, 10VA or 16V AC, 14VA w/no load voltage 20V or less. Intercom + Electric door strike; 12V AC, 10VA only Door calls in w/4- or 2-tone chime and LED, 45 sec. Pick up any handset to reply. Press 1 ~ 6 to call other station with pretone and voice or All Call. Single channel, common talk system. Contact rating: 24V AC/DC, 350mA. 2 parallel wires, to door. 4 wires in loop, between rooms. IE-8MD to door 150m(0.65mma) 360m(1.0mma) Rooms 75m(0.65mma) 190m(1.0mma) Audio Door Stations IE/IF Series Unit dimensions 98 AX-DM 135 IE-DC 130 IF-DA 83.5 28 100 IE-DC IF-DA 83.5 IE-JA 34 43 IE-FY 220 83.5 128 115 116 10 160 AX-DM Specifications Audio door station Mullion type Wiring Wiring distance Features Used for l Weather resistant audio door stations l Hands-free communication l Call button rings chime or tone at inside station IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-8MD, TD-nH/B w/DE-UR (n=3, 6, 12 & 24) TC-M w/TB-AD1 TC-M w/TB-AD10 AX Some applications l At multiple doors w/TB-ADM10 in place of video door AUDIO ENTRY SECURITY IE-FY Door station 66 2 parallel wires to master, non-polarized 150m(0.65mma) 230m(0.8mma) 360m(1.0mma) Flush mount station Door station 22.5 Door station Door station IE-JA 160 Surface mount station IE-DL Series Unit dimensions Surface mount station 175 IE-DL1, IE-DL2, IE-DL3 IE-DL1 83.5 1-call surface-mount door station 120 25.5 Specifications IE-DL2 2-call surface-mount door station Power source Communication Wiring Wiring distance IE-DL3 3-call surface-mount door station 12~16V AC, 140mA or 12~24V DC, 140mA. Press CALL to ring a flat station. Talk hands-free after the inside station replies. 4 to 8 wires, polarized. 150m(0.65mma) 230m(0.8mma) 360m(1.0mma) Features Used for l 1~3-call surface-mount door station with aluminum panel. l Directory back illumination. l AC/DC power source. IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-2A2D(U), IE-8MD, TD-nH/B w/DE-UR (n=3, 6, 12 & 24) 34 Hands-free Color Video BUS Apartment System The GH system is Hands-free Color video apartment system employing 1pair for Audio & 1pair for video connections. The resident can easily identify visitors by crisp "Color image" together with convenient "Hands-free communication." The GH system configures basically two systems: Standard 48-station, Expanded 500-station systems. Apartment station is selectable out of three types: Color monitor hands-free station (w/optional handset), B&W monitor hands-free station, and hands-free audio station. Entrance station is of a fully modular design with vandal-resistant zinc die-cast panel. The GH system is totally flexible, allowing you to mix-and-match components to create the exact system configuration and features needed for each application. Capacity Standard Expanded 48 500 Apartment station MULTI-UNIT ENTRY SECURITY • Identify visitors by crisp "COLOR" image • Convenient "Hands-free communication" • Up to 4 apartment stations can be linked per Residence (max. 2 monitor stations) • Monitoring an Entrance camera from Apartment monitor station • Add an external signaling device to Apartment station • Call tone off at individual station with LED indicator • Doorbell at individual door • Auto-Entry (Doctor call) • User-optional feature using SERVICE button, such as turning on/off light, elevator control, etc. • Panic call transfer to security guard station Color monitor hands-free station B&W monitor hands-free station Audio hands-free station Color monitor hands-free station with optional handset * The design and specifications are subject to change without notice for improvement. 35 Apartment Station Simple and easy installation • Two single-pair BUS for audio & video • Easily links Entrance station to Apartment station • Resident names & room numbers etc. are programmable by PC Entrance station Security guard station Capacity Capacity Expanded 5 16 Entrance station • Vandal-resistant zinc die-cast panel • Sleek & compact semi-flush design • Digital name scrollings - Search resident names and room numbers using keypad - Customer programmable welcome messages - Names & welcome messages are selectable from 5 different languages (English, French, Spanish, German & Dutch) Standard Expanded 2 4 Security guard station • Communicate with all residents and Entrance stations • Receive all Entrance station call-in (Reception mode function) • Absence call-in memory stored with Callback • Receive panic calls from Apartment stations MULTI-UNIT ENTRY SECURITY Standard 36 Hands-free Color Video Bus Apartment System System Configuration Standard system Divided cabling with GH-4Z Trunk line No.1 5 Entrance stations 2 Security guard stations 48 Residential stations Monitor to monitor cabling Trunk line No.6 1Px2 1Px2 On the same trunk line, do not have two wiring methods mixed, Divided cabling with GH-4Z & Monitor to monitor cabling 1Px2 1Px2 1Px2 GH-4Z 1Px2 1Px2 GH-1KD GH-1KD GH-1MD 1Px2 GH-1KD GH-1KD 1Px2 1Px2 1Px2 1Px2 GH-4Z 1Px2 GH-1KD GH-1KD GH-1MD 1Px2 GH-1KD 1Px2 1Px2 GH-1KD 1Px2 1Px2 1P 1Px2 1Px2 1P GH-4Z MULTI-UNIT ENTRY SECURITY Doorbell GH-1KD Doorbell GH-1MD 1Px2 GH-1KD + GH-HS GH-1AD Apartment No.2~5 300m / 0.8mma 1Px2 150m / 0.8mma 1Px2 1Px2 PS24 1P 1P GH-BC PS24 1P Entrance Station : Max. 5 Wiring distance: Entrance station - Bus & Video control unit 300m Video control unit - Farthest Video Apartment station 150m (Expandable with additional Video control unit) Bus control unit - Farthest Audio Apartment station 300m Accumulated total Audio wiring distance 2,500m 37 GH-1KD GH-1KD GH-1AD GH-VBC PS24 1P 1P PS24 1P 1P GH-MK GH-MK Security Guard Station : Max. 2 Expanded system 16 Entrance stations, 2 common trunk lines (8 each per common line) 4 Security guard stations, 2 common trunk lines (2 each per common line) 500 Residential stations, 4 sub trunk lines (125 each per sub trunk line) Trunk line No.1 No.6 No.1 Apartment station Max.125 /SUB line No.6 Apartment station Max. 125 /SUB line 1Px2 No.2~5 1Px2 GH-BC PS24 1Px2 1Px2 1Px2 1Px2 GH-VBC PS24 1Px2 No.2~5 GH-BC PS24 1Px2 GH-VBC PS24 SUB COMMON 2 & 3 300m / 0.8mma 1Px2 1Px2 SUB COMMON 1 SUB COMMON 4 1Px2 1P 1Px2 1P 1P 1P 1P GH-BCX PS24 GH-BC PS24 1Px2 1P GH-VBX 1P GH-BC PS24 COMMON 2 1P 1P PS24 1P 1P GH-MK GH-MK Security Guard Station Max. 2/COMMON line Entrance Station Max. 8/COMMON line COMMON 2 1Px2 1P PS24 PS24 150m / 0.8mma 1P 1P PS24 Entrance Station Max. 8/COMMON line 1P 1P MULTI-UNIT ENTRY SECURITY COMMON 1 COMMON 1 GH-MK GH-MK Security Guard Station Max. 2/COMMON line Wiring distance: Entrance station - Expanded Bus & Expanded Video control unit 300m Expanded Video control unit - Farthest Video Apartment station 150m (Expandable with additional Video control unit) Expanded Bus control unit - Farthest Audio Apartment station 300m Accumulated total Audio wiring distance 2,500m/SUB line 38 Hands-free Color Video Bus Apartment System Entrance station Direct-select call button Digital name scrolling The directory button panels back-lit display illuminates resident's name or unit number Color camera VFD Display Directory scroll/ Cancel/ Call buttons Zinc die-cast panel Keypad illumination Audio module Access control/ room number dialing keypad In-use LED Call button Directory card & cover Audio Module GH-DP Audio panel Digtal name scrolling module GH-DA Audio module GF-NSP GH-NS Display module panel Digital name scroll display module Front frame & back box Camera Module MULTI-UNIT ENTRY SECURITY GF-2F 2-module front frame GF-VP GH-VA GF-10KP Camera panel Camera module GH-10K 10-key module panel 10-key module GF-3F 3-module front frame Call switch Module GF-1P GF-2P 1-call panel 2-call panel GF-2B 2-module back box GF-3P 3-call panel GF-4P GH-SW 4-call panel Call switch module GF-AP GH-AD GF-BP Address panel Address module Blank panel Option 39 GF-3B 3-module back box Specifications (GH-DA,GH-VA) System layout example Wiring Type of cable Direct-select call button 1P l Searches of resident names and room number using the keypad l Customer programmable welcome messages can also be shown in 5 different languages (English, French, German, Spanish & Dutch ) l White LED illuminator truns on in low-light conditions 1P #2 1P #1 1P Mounting H GH-BC M Housing N H Specifications (GH-SW,GH-10K,GH-AD) M Lighting Housing GH-VBC N Digital name scrolling 1P 1P 1P #1 1P Yellow LED Fire-retardant plastic Specifications (GH-NS) 1P #2 Two single-pair cable common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Box and front frame GF-2B,3B and GF-2F,3F Fire-retardant plastic Power source 1P 1P 1P Housing N DC 24V, supplied by PS-2410LD, LC Fire-retardant plastic GH-BC N GH-VBC N Unit dimensions GH-DA GF-VP 95.2 93 7.9 GH-VA 95.2 GH-DP 110 93 49.5 108 15.8 4.5 38 105.6 GH-NS 9.9 28.9 38 9 GF-2B 295 16 16 4.5 38 106.2 GF-3B 200 320 225 GF-3F 135 14.4 110 106.2 GF-2F GH-10K 95.2 95.2 14.4 110 110 44 135 42 85 GF-202HB 110 44 243 GF-202H 243 22 4-call 290 290 65 Audio/Video + Name scroll 225 AIPHONE 320 Hooded surface-mount box GF-10KP 100.3 GF-NSP 88.3 110 GF-nHB 52.3 MULTI-UNIT ENTRY SECURITY Rain hood 108 110 88.3 GF-nH 7.9 51 GH-SW 95.2 GF-4P AIPHONE 270 135 16 16 44 44 40 Hands-free Color Video Bus Apartment System Entrance station components Number of calling button 4. 8. 12. AIPHONE AIPHONE 16. AIPHON E 20. AIPHON E 24. 25.~48. AIPHONE AIPHONE GH-NS, GF-10K AIPHON E AIPHON E (1) (2) (3) (4) (5) (6) (7) GH-VA GF-VP GH-DA GH-DP GH-SW GF-4P GF-2F GF-2B GF-3F GF-3B GF-BP GH-AD GF-AP GH-NS GF-NSP GH-10K GF-10KP 1 1 1 1 1 1 1 1 - 1 1 1 1 2 2 2 2 - 1 1 1 1 3 3 2 2 - 1 1 1 1 4 4 2 2 - 1 1 1 1 5 5 3 3 1 1 1 1 1 6 6 3 3 1 - - 1 - 1 - - - - - - - - 1 1 1 1 1 1 1 1 2 2 - For more than 7 GH-SW, install additional power supply & special device required. Contact local AIPHONE distributor (1) Camera (2) Audio (3) Call switch (4) 2-module Front frame (5) 3-module Front frame (6) Option (7) Digital name scroll Interconnecting Modules with Plug-in Conectors Mounting . GF-nH W GF-3B . GF-nHB 42 W 85 GH-DA GH-DP GF-3F (4) H H CN3 (3) GH-SW GF-4P (5) (2) (1) CN1 65 22 H W GF-102H/HB 243 155 GF-202H/HB 243 290 GF-103H/HB 338 155 GF-203H/HB 338 290 GF-303H/HB 338 425 CN1 CN2 CN2 CN1 CN1 CN2 CN2 CN1 MULTI-UNIT ENTRY SECURITY (1) Tamper-proof screw & screwdriver (supplied with GH-BC) (2) Module-mounting bracket (supplied with GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance. Back box 1. GH-VA 2. (1) (1) 3. 200 mm 295 mm 25mm 44mm W (2) 25mm 25mm W 44mm (2) 1. Two 2-module back boxes 2. Three 3-module back boxes (1) Joint pipe(x2) (2) Do not recess back box more than 15mm. GF-2B/3B x1 x2 x3 x4 x5 x6 x7 x8 x9 W 110 245 380 515 650 785 920 1055 1190 GH-NS CN3 CN1 CN3 CN1 CN2 GH-DA GH-10K 3. Back box total width (mm) Adjust camera angle • Viewing from initial camera position • Changing camera angle • Image view area GH-VA 95cm Camera center GH-VA 50cm 65cm 113cm 24cm GH-VA GH-VA 65cm 1. Open the rubber cap. 2. Change the camera angle with the lever 113cm 24cm *Do not forget to replace the cap. 50cm 41 When adjusted to the left When adjusted to the right Residential station Features GH-1KD GH-1KDS (white) (silver) Color monitor apartment station • Selectable 3 types of stations (Color monitor, B&W monitor, or Audio only) • Hands-free communication, auto-voice actuation • Press-talk operation available • Max. 4 apartment stations can be linked per Residence (max. 2 monitor stations) • Monitoring a Video entrance station (audio & video) • Call tone cutout with LED indicator • Security guard call • Additional handset available for GH-1KD • Option External signaling device to Apartment station (w/GH-RY) Doorbell at individual door with different call tone Auto-Entry (Doctor call), door strikes automatically opens by pressing the Call button at the entrance station. (Not available to use together with entrance light feature) -Panic call, call an Emergency to the Security guard station(s) by panic call button User-optional device can be controlled with SERVICE button, such as -Light on and off at entry way to elevator -Elevator control, goes down to the ground floor or up to resident floor Not available GH-1MD Functions Specifications (GH-1KD, GH-1MD, GH-1AD) Buzzer Apartment station Power source DC 24V, supplied from Bus control units, GH-BC & GH-VBC Video monitor GH-1KD: 3-1/2 inch color LCD GH-1MD: 4 inch B&W CRT Wiring GH-1KD, GH-1MD: Two Single –pair cables common GH-1AD: Single-pair cable common Mounting Wall-mounting only Housing Fire-retardant plastic External signaling Panic alarm Cal ling &C Do or r om ele mu Mo nic nito ase atio rin n g (a udi o/ vid eo) B&W monitor apartment station ory em n larm g m atio ic a callin unic Pan ce mm Co sen Ab ng & li Cal GH-1MD O PANIC CALL switch Doorbell Door release Monitoring (audio) Reception mode function Entrance station Security guard station Trunk line Unit dimensions Audio apartment station Monitor to monitor cabling Divided cabling with GH-4Z 175 GH-1KD GH-1AD 1Px2 1Px2 1Px2 125 32 GH-1MD 210 1Px2 GH-1KD GH-1KD MULTI-UNIT ENTRY SECURITY Calling & Communication GH-1KD 1Px2 GH-4Z 160 55.5 GH-1AD Only available to connect on a trunk line with GH-4Z used GH-HS Option handset for GH-1KD 175 1Px2 GH-1AD GH-1KD 1Px2 125 32 GH-HS On the same trunk line do not have two wiring methods mixed, Divided cabling with GH-4Z & Monitor to monitor cabling 140 GH-1MD 1Px2 177 1Px2 45 46 42 Hands-free Color Video Bus Apartment System Security guard station Features Unit dimensions GH-MK Security guard station GFW-S Desk-top stand 60 83.5 210 l Call to residential station GH-MK l Digital display shows name of resident & room number l Monitoring a Video entrance station (audio) l Receive all Entrance station call-ins (Reception mode function) 215 69 l Absence call-in memory stored with Callback l Option Specifications (GH-MK) Doorbell at door with different call tone User-optional device can be controlled with Power source DC 24V, supplied by PS-2410LD, PS-2410LC SERVICE button, such as Max. 16 letters for names; English, VFD display -light on and off at entry way to elevator French, German, Spanish & Dutch l Receive a Panic call from apartment station Wiring Type of cable 2 single-pair cables 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Mounting Wall-mounting or Desk-top mounting on GFW-S Fire-retardant plastic Housing Control units System layout example 1P(Audio) 1P(Video) BUS (Audio/Video) MAX.6 Monitor to monitor cabling Divided cabling with GH-4Z 1 2 3 4 5 6 150m Expand pos. 1Px2 1Px2 GH-4Z GH-1KD GH-1KD GH-1KD EXP GH-1KD GH-VBC GH-1KD MULTI-UNIT ENTRY SECURITY GH-BC Bus control unit STD max. 2 On a single trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GH-4Z GH-BC GH-VBC PS24 PS24 150m GH-1KD PS24 GH-BC GH-VBC PS24 1Px3 PS24 PS24 EXP STD Standard pos. Wiring distance GH-VBC Video Bus control unit, expander video control GH-BC, GH-VBC to Farthest Entrance station GH-BC, GH-VBC to Farthest Video apartment station GH-BC, GH-VBC to Farthest Audio apartment station GH-BC, GH-VBC to each Power supply GH-RY to Entrance station Accumulated Audio lines (R1, R2) Total wiring distance Distance (Diameter of wires) 300m(0.8mm) 150m(0.8mm) Expandable 150m with additional GH-VBC & Power supply 300m(0.8mm) 5m(0.8mm) 300m(0.8mm) 2,500m(0.8mm) Type of Cable 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Specifications (GH-BC, GH-VBC) Unit dimensions Power source GH-4Z Consumption Wiring Housing 108.5 Video 4-zone divder GH-BC, GH-VBC, GH-4Z 122.5 43 DC 24V, supplied by PS-2410LD, PS-2410DIN 900mA. Single-pair cable common Fire-retardant plastic Specifications (GH-4Z) 61 Wiring Mounting Housing Two Single-pair cables common DIN rail Fire-retardant plastic Expanded control units Features Available 2nd Quarter 2006 l Expandable to max. 500 Apartment stations, 16 Entrance stations, and 4 Security guard stations System layout example GH-1KD GH-BCX Expanded Bus control unit GH-BC GH-VBC PS24 PS24 GH-1KD GH-BC SUB2 SUB3 1Px2 SUB1 PS24 1Px2 GH-VBC PS24 SUB4 1Px2 COMMON 1 COMMON 1 PS24 PS24 GH-BCX GH-VBX PS24 PS24 1Px2 COMMON 2 PS24 GH-MK COMMON 2 GH-MK GH-MK GH-MK PS24 GH-BC GH-BC PS24 PS24 l COMMON trunk line: Requires one each of GH-BC & Power supply l COMMON trunk line: Max. 8 Entrance stations & 2 Security guard stations l SUB COMMON trunk line: Max. 125 Apartment stations GH-VBX Expanded video control unit Specifications (GH-BCX, GH-VBX) Unit dimensions GH-BCX, GH-VBX Power source GH-BCX: DC 24V, supplied by PS-2410LD, 108 PS-2410LC. GH-VBX: Supplied from GH-BCX 61 210 Wiring Single-pair cable common Mounting DIN rail Housing Fire-retardant plastic Power supply Specifications PS-2410LD PS-2410LC 164 RD BK RD : Red, BK : Black PS-2410LD PS-2410LD PS-2410LC Power source AC220-240V AC120V Secondary output voltage & current DC24V, 1A DC24V, 1A 66 95 Power supply PS-2410LC MULTI-UNIT ENTRY SECURITY Unit dimensions Option GH-RY External signaling relay entrance light, external buzzer W-DIN11 DIN mounting rail for GH-BC, GH-VBC, GH-4Z 44 Hands-free Color Video Bus Apartment System Preliminary Information Available mid. 2007 GH Lift control adaptor Features l Lift is controllable from apartment station while communicating with entrance station. When door release button is pressed, electric door strike is activated and simultaneously output signal is transmitted to the lift controller or the access controller. l Selectable dry contact: Normally Open or Normally Closed l System set up data is programmable on your PC * GH-BCX/A & GH-DA/A is required to use GHW-LC. GHW-LC Lift control adaptor Functions Cabling 1P(Audio) 1P(Video) 1P GH-1KD 1P×2 un eas e mm rel Co or Do Distribution point PS24 PS24 ) Ca on cti g& ea llin GH-VBC (on 1P×2 GH-BCX/A SUB1 GH-VBX Entrance station Lift PS24 COMMON 1 Unit dimensions GH-BC GH-BC GHW-LC Distribution point PS24 Distribution point PS24 108 MULTI-UNIT ENTRY SECURITY GH-BC ol ntr Co ica tio n GH-1KD 210 61 1P×2 PS24 GHW-LC Specifications Power source Relay Wiring Mounting Housing Supplied by GH-BC Output 20 Contact rating 24V AC/DC, 0.5A N/O or N/C dry contact Operating time From 1 to 600 second Single-pair cable DIN rail Fire-retardant plastic GH-MK PS24 Entrance station Lift PS24 :PS-2410LD, 45 PS-2410LC Lift controller *Not available in Europe GH CCTV camera interface adaptor for Reception Features Tenant can receive a call from concierge with visitor’s picture image through CCTV camera. In luxurious condominium, concierge receives all visitors directly instead of using the entrance station. In case concierge asks the tenant to verify the visitors, GH-CCTV allows GH-MK to call apartment station with the image from CCTV transferred. The tenant can communicate with concierge while the picture of visitor displayed at the apartment station. Monitoring the CCTV camera is also available from the apartment station. GH-CCTV CCTV camera interface adaptor for Reception Functions Cabling 1P(Audio) 1P(Video) 1P CCTV camera Video CCTV camera Monitoring (Video) Coaxial cable GH-1KD Power supply GH-1KD GH-CCTV tio a nic Monitoring only u m om 1P×2 C 1P×2 GH-BC GH-VBC GH-MK PS24 PS24 CCTV camera Coaxial cable Unit dimensions Power supply GH-CCTV GH-CCTV 205 340 Mounting 1P×2 93 Specifications Power source Video signal 1P×2 MULTI-UNIT ENTRY SECURITY n g llin Ca GH-MK Supplied by GH-BC & GH-VBC NTSC 1V P-P 75d Desk-top or wall-mounting PS24 Parking lot PS24 :PS-2410LD, PS-2410LC 46 Hands-free Color Video Bus Apartment System Cabling 1P(Audio) 1P(Video) 1P Standard system Capacity 5 Entrance stations 2 Security guard stations 48 Residential stations Monitor to monitor cabling Divided cabling with GH-4Z Trunk line No.2 1Px2 Trunk line No.1 1Px2 Doorbell 1Px2 GH-4Z 1Px2 GH-1KD 1Px2 1Px2 1Px2 1Px2 1Px2 1P 1P 1Px2 GH-4Z Doorbell Doorbell Doorbell Doorbell GH-1KD GH-1KD GH-1KD GH-1MD GH-1MD, unlike GH-1KD, is only available to connect on a trunk line with GH-4Z used 1Px2 GH-1AD GH-1AD GH-1KD Max. 4 apartment stations can be linked per Residence (including max. 2 monitor stations) 1Px2 On the same trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GH-4Z 1Px2 MULTI-UNIT ENTRY SECURITY Trunk line No. 3 to 6 1Px2 Distribution point R1 PS24 R2 PS24 GH-BC GH-VBC 1Px2 Light control Timer Entrance No. 2 to 5 GH-RY 1Px2 1P 1P AC 1P Light PS24 Door release Doorbell PS24 GH-MK Entrance station Security guard station Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation 47 Wiring Monitor to monitor cabling Divided cabling with GH-4Z Trunk line No.2 Trunk line No.1 GH-4Z A B R1 R2 B1 B2 GH-1KD OUT B1 B2 R1 R2 B1 B2 LINE OUT B1 B2 OUT 3 OUT 4 R1 R2 1Px2 B1 IN B2 OUT IN R1 R2 R1 R2 C CE A B Terminate the last GH-4Z 1Px2 B1 B2 R1 R2 A IN IN B1 B2 OUT 1 R1 R2 B1 B2 OUT 2 R1 R2 LINE IN R1 R2 B1 B2 R1 R2 C CE GH-1MD R1 OUT R2 R1 OUT R2 R1 IN R2 C CE R1 IN R2 C CE GH-1AD GH-1AD Doorbell 1Px2 R1 OUT R2 R1 IN R2 C CE A B1 OUT B2 1Px2 B1 B2 R1 OUT R2 B1 IN B2 B 1Px2 B1 IN B2 B1 OUT B2 1Px2 GH-4Z Doorbell B1 OUT B2 Doorbell Door bell 1Px2 B R1 IN R2 C CE A B GH-1KD B1 OUT B2 GH-1KD B1 IN B2 B1 IN B2 R1 OUT R2 R1 OUT R2 R1 IN R2 C CE R1 IN R2 C CE A Door bell B A B GH-1KD GH-1KD 1Px2 Trunk line No. 3 to 6 GH-BC R1 R2 + - + - + - B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 Power supply OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 IN1 AC IN2 IN3 IN4 AC Power supply IN5 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 + - EXP MULTI-UNIT ENTRY SECURITY Distribution point 1Px2 STD Video Entrance station No. 2 to 5 Light control Timer Orange Blue 1Px2 GH-MK 1P Orange GH-RY White Light GH-DA Doorbell CN2 R1 R2 ELB ELC ELM RY RY CN1 A1 A2 CN3 + GH-VA GH-NS CN1 + CN3 - AC + - AC - CN100 R1 R2 R1 R2 R1 R2 C CE + - R1 R2 C CE + - Power supply Power supply GH-10K 2nd GH-MK SW1 SW1 Entrance station Apartment station and Security guard station have following options GH-1KD, GH-1MD, GH-1AD l Doorbell l Panic alarm switch l User-optional device*(not available with GH-1MD) l External buzzer* l Doctor call* Doorbell button *Option connector cable is required. Contact local AIPHONE distributor locally available R1 R2 C CE K KE •• •• •• Option connector cable User-option device External buzzer Doctor call GH-MK l Doorbell l User-optional device* l External buzzer* R1 R2 C CE •• •• •• Option connector cable User-option device External buzzer Doorbell button Panic Call switch (w/break contact) locally available *Option connector cable is required. Contact local AIPHONE distributor 48 Two-Wire Bus System ENTRANCE 5 RESIDENCE 100or250 GF Audio Entrance station Entrance station modules l Direct-select Call Button l Digital Name Scrolling l Audio Module l Direct-Select Keys GF-DP GF-1P GF-2P Audio panel m P.55 1-call panel m P.55 2-call panel m P.55 GF-DA GF-3P GF-4P Audio module m P.55 3-call panel m P.55 4-call panel m P.55 Audio, Digital keypad, LCD Directory & address panels Audio, 4-call Audio, 16-call with address panel Frame & Box Assemble the following in as many rows as required. GF-2F 2-module Front frame GF-2B 2-module Back box GF-3F 3-module Front frame GF-3B 3-module Back box GF-SW Call switch module m P.55 PP.56 Features Communication network MULTI-UNIT ENTRY SECURITY l Fully modular Entrance station. Vandal-resistant construction l Two-wire Bus throughout system l One or two apartment stations l Call tone off at individual station with blinking LED indicator l Door release & external light, Bus line-controlled l User options: Doorbell at individual door. Auto-Entry (auto door strike) l User-optional feature using SERVICE button GF-1DK GF-1DK GF-1DK Capacity l 1 or 2 apartment stations within a residence l Entrance station panel : 100-call sized l Direct-select call button : Total 150 apartment stations incl. second stations l Digital name scrolling : Total 250 apartment stations incl. second stations GF-1DK O 1. GF-MK 1 A 2 B C D 3 E G 4 H 5 I J K L M PQ 8 R T U F 6 N 7S O 9Z WX V Y 0 1. M GF-MK 2. 1 A 2 B C D G 5 I J K L M PQ V O 9Z WX T U F 6 N 8 R 3 E 4 H 7S Y 0 2. 5. J Calling & Communication K PANIC CALL sounding & Answer-back. GF-MK; Concierge station must be used w/GF-1DK. I Doorbell O PANIC CALL switch used for GF-1DK only Bus line-controlled; M Door Release L External light 49 l Digital Name Scrolling Apartment station Concierge station Bus control unit Lineup GF-NSP LCD directory panel m P.55 GF-BC GF-nH GF-nHB Rain hood m P.56 Hooded surfacemount box m P.56 GF-AP GF-AD Address panel m P.55 Address module m P.55 GF-BP GFW-S Bus control unit m P.58 GF-NS LCD directory m P.55 Power supply GF-10KP Blank panel m P.55 GF-MK GF-1D Digital keypad panel m P.55 Concierge station m P.57 Apartment station m P.57 Desk-top stand for GF-MK m P.57 GF-1DK Concierge call apartment station w/Panic call transfer Use with GF-MK m P.57 GF-10K Digital keypad m P.55 GFW-LD PS-2410LD m P.58 m P.58 Cabling Long distance adaptor m P.59 PS-2410LC Wiring 2.BUS 2.BUS 1P 1P GF-1DK x 2 1P 1P 1P R1 R2 GF-1DK 1P 1P GF-1DK 1P 1P 1P 1P 1P R1 R2 1P 1P C CE C CE R1 R2 R1 GF-1DK R2 1P 1P C CE C CE O K KE 1P 1.BUS 1.BUS 3.BUS C CE O GF-BC 1P 1P (NP) 1P (NP) 1P (NP) R1, R2 1P 1P 1P R1 R2 1P R1 R2 1P R1 + R2 – 1P R1 R1 R2 R2 1 M PQ L PQ V O 9Z WX T WX T U F 6 N 8 R 3 E J M G J l Bus line: Any number per system. Max. 50 stations per line. 1P, Non-polarized D G GF-MK C 5 I K 7S Y 0 GF-MK L H ML H B2C K5L E3F N6O Y9Z WX B 4 H O Y U8V T 2 F 6 9Z PQ 1 3 A D L N V 0 2.GF-MK M C E K U 0 R7S J A 2 B 5 I 8 R H4I G 1P 1 4 H 7S EL EL + b A EL EL + b 1P N D GF-BC N 1P 1P MULTI-UNIT ENTRY SECURITY GF-1DK GF-1DK GF-1DK R1 x 2 R2 GF-1DK 1.GF-MK M l Bus line (MAX.) 50 stations per Line l K, KE terminals; Mounted on GF-1DK only l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry closure contact. N : PS-2410LD, PS-2410LC 50 Four-Wire Common Video System ENTRANCE 5 RESIDENCE 100or250 GF Audio/Video Entrance station modules Entrance station l Direct-select Call Button l Digital Name Scrolling l Camera Module l Audio Module l Direct-Select Keys GF-VP GF-DP GF-1P GF-2P Camera panel m P.55 Audio panel m P.55 1-call panel m P.55 2-call panel m P.55 GF-VA GF-DA GF-3P GF-4P Camera module m P.55 Audio module m P.55 3-call panel m P.55 4-call panel m P.55 l Audio Module Audio, Camera & Digital Keypad & LCD Directory Audio, Camera & Direct-select 12-call buttons Frame & Box Assemble the following in as many rows as required. GF-2F 2-module Front frame GF-2B 2-module Back box GF-3F 3-module Front frame GF-3B 3-module Back box GF-SW Call switch module m P.55 PP.56 Features Communication network MULTI-UNIT ENTRY SECURITY l Fully modular Entrance station. Vandal-resistant construction l Two single-pair cables run throughout system l Second monitor or audio station can be installed l Call tone off at individual station with blinking LED indicator l Door release & external light, Bus line-controlled l Optional functions: Doorbell at individual door. Auto-Entry (auto door strike) l User-optional feature, using SERVICE button GF-1MDK x 2 GF-1MDK Capacity l 1 or 2 apartment stations within a residence l Entrance station panel : 100-call sized l Direct-select call button : Total 150 apartment stations incl. second stations l Digital name scrolling : Total 250 apartment stations incl. second stations GF-1MDK O 1. M 1 A 2 B C D G 5 I J K L M PQ O 9Z V WX T U F 6 N 8 R 3 E 4 H 7S Y 0 2. GF-MK 5. 1 A 2 B C D G 5 I J K L M PQ V O 9Z WX T U F 6 N 8 R 3 E 4 H 7S Y 0 GF-MK J Callig & communication K PANIC CALL sounding & Answer-back. GF-MK; Concierge station must be used w/GF-1MDK. I Doorbell O Panic call switch, available with GF-1MDK only Bus line-controlled; M Door Release L Light 51 Apartment station l Digital Name Scrolling Concierge station Bus control unit Lineup GF-BC Bus control unit m P.58 GF-NSP LCD directory panel m P.55 GF-NS LCD directory m P.55 GF-VBC GF-4Z Video control unit m P.58 4-apt. Bus junction unit m P.58 GF-nH GF-nHB Rain hood m P.56 Hooded surfacemount box m P.56 GF-AP GF-AD Address panel m P.55 Address module m P.55 GFW-S GF-BP Power supply GF-10KP GF-1MD Digital keypad panel m P.55 GF-MK Apartment station m P.57 Desk-top stand for GF-MK m P.57 Concierge station m P.57 GF-1MDK Concierge call apartment monitor station w/Panic call transfer Use with GF-MK m P.57 GF-10K Digital keypad m P.55 PS-2410LD PS-2410LC m P.65 m P.58 Cabling Blank panel m P.55 Wiring 1.BUS 2.BUS GF-1MDK 1P x 2 SW1 A GF-1MDK (x 2) OUT B IN B1 B2 B1 B2 R1 R2 R1 R2 OUT IN C CE K KE GF-1MDK 1P x 2 2 OUT SW1 O B A IN 2 SW1 GF-1MDK 1P x 2 OUT B A IN B1 B2 B1 B2 R1 R2 R1 R2 B1 B2 B1 B2 R1 R2 R1 R2 OUT IN C CE K KE O OUT IN C CE K KE O GF-1MDK 2 OUT SW1 GF-1MDK B A IN R1 R2 R1 R2 B1 B2 B1 B2 OUT IN C CE K KE O 1P x 2 GF-1MDK VIDEO AUDIO 1.BUS 2 GF-VBC 1. ~ 6. BUS(Video) 6 1P x 2 VIDEO 1P x max.6 VIDEO AUDIO AUDIO (1) 1P 1P 1 A 2 B G J L 1P 1 C 5 I K L M PQ 8 R V O 9Z WX T U F 6 N 7S 3 E 4 H J WX T Y 2 B O 9Z G PQ V 0 D M U F 6 N 8 R A 5 I K 7S 3 E 4 H Y + B1B2 B1B2 B1B2 B1B2 B1B2 B1B2 – OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 N + – GF-VBC IN5 IN3 IN2 R1, R2 IN1 N 2.GF-MK R1 R1 R2 R2 GF-MK A1A2 A1A2 A1A2 A1A2 A1A2 1 2 B 4 H C K L PQ 8 R V O 9Z WX T U F 6 N 7S 3 E 5 I M N N IN4 R1 + R2 – GF-BC 1 J N + N 0 2 G GF-BC 3 D GF-VBC 4 A 1P x 2 C D 1P x 2 5 MULTI-UNIT ENTRY SECURITY O Y 0 GF-MK GF-MK A1A2 R1 R2 GF-DA Audio/Video trunk lines l There are methods of installing audio/video trunk lines, i.e. Monitorto-Monitor or homerun to GF-4Z’s. The two methods may be used within a system. But do not mix two methods on a same trunk line. l BUS (Audio/Video) Line; Up to 6 lines. Two single-pair cables common. Max. 25 Monitors per Line. A1A2 R1 R2 GF-DA (1) Required when the second GF-1MDK is installed within an apartment. l K, KE terminals for Panic call switch; GF-1MDK only. l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry closure contact. N : PS-2410LD, PS-2410LC 52 Two-Wire Bus System ENTRANCE 8 RESIDENCE 4,800 GF Multi-Tower Multi-Tower System GF-GD-TS Central entrance station (Audio only) GF-GMK Central security guard station VGX-D-YBOX Built-in back box GF-6GX24-2 Central control unit Power supply PS-2410LD (GF) m P.58 PS-1215DIN (Central) Features Communication network l Max. 24-Tower, 4,800-Residence System l Two-pair cable throughout GF standard Single-tower system l Panic call annunciation to Central & Single-tower security guard stations l Audio only Central entrance stations with two talk channels C GF GF-1MDK MULTI-UNIT ENTRY SECURITY AIPHONE GF-MK A GF-GD-TS Capacity Multi-tower No. of Towers Central security guard station Central entrance station (audio) Residential monitor station Single-tower Security guard station Entrance station (audio/video) Resodential monitor station 53 24 bldgs. 4 pcs 8 pcs 4,800 pcs 1 pce 4 pcs 250 pcs B GF-GMK (A) COMMON ENTRANCE (B) SECURITY GUARD (C) Single-tower RESIDENTIAL MONITOR Doorbell PANIC CALL P Callig & Answering J Callig & communication (both ways) X Door strike Y Panic call *Not available in Europe, Australia, nor New Zealand Single-Tower System GF Entrance station w/Digital name scrolling m P.55 GF-MK GF-1MDK GF-1DK Concierge call apartment monitor station (w/Panic call transfer) m P.57 Apartment station (concierge call) w/Panic call transfer m P.57 Concierge station m P.57 GF-GTX Single-tower control unit Wiring Unit dimensions GF-GD-TS 5P GF-GTX 5P GF-GTX 5P GF-GTX 5P PS PS GF-GD-TS 3P PS PS PS 300 GF-GMK GF-GTX 3P PS PS GF-GD-TS 3P 5P GF-GTX 5P PS GF-GTX 5P PS PS PS GF-GMK PS 20 80 98 340 GF-GTX 5P GF-GMK (1) (2) 107 106 GF-GTX 3P GF-GTX 5P GF-GTX 5P GF-GTX 5P GF-6GX24-2 3Px 8 PS PS PS PS 1 2 4 5 7 8 9 0 C 320 GF-GTX 5P 230 PS MAX. 300m 3 6 3Px 4 PS GF-GD-TS 3P MAX. 300m PS GF-GTX 5P GF-GTX 5P PS PS PS GF-GTX PS GF-GMK PS GF-GD-TS 3P GF-GTX 250 5P 230 80 3P GF-GD-TS 3P GF-GD-TS 3P GF-GTX 5P GF-GMK 5P PS GF-GTX 5P PS GF-GTX 5P GF-GTX MULTI-UNIT ENTRY SECURITY GF-GTX 460 C 1Km 350 A GF-GD-TS 3P GF-6GX24-2 2.5Km GF-GMK (1) Desktop (2) Wall mounting 5P 3P 1Km PS PS B PS GF-GTX 5P PS GF-GTX 5P PS GF-GTX 5P GF-GTX 5P PS PS PS PS PS 1Km Multi-tower trunk line (A) Common entrance 300m/unit (farthest). 1Km(cumulative All stations) (B) Central security guard 300m/unit (farthest). 1Km(cumulative All stations) (C) Tower interface adaptor 1km/unit (farthest). 2.5Km(cumulative All units) C : PS-1215DIN Specifications (GF Multi-tower) Power source & consumption GF-GGX24-2: 12V DC, 24W (Standby 16W) GF-GD-TS: 12V DC, 200mA (100mA) GF-GMK: 12V DC, 350mA (120mA) GF-GTX: 12V DC, 2.0W (1.5W) PS-1215DIN Power supply Electric tone, Central entrance to Residence Communication Twisted pairs CPEV, 0.9mm dia. Cable 5 twisted pairs, CPEV0.9mm, CCU ~ GF-GTXs Wiring 3 twisted pairs, CPEV0.9mm, CCU ~ GF-GMKs 3 twisted pairs, CPEV0.9mm, CCU ~ GF-GD-TS Distance 300m/0.9mm, CCU ~ GF-GD-TS (8 pcs total 1Km) 300m/0.9mm, CCU ~ GF-GMK (4 pcs total 1Km) 1Km/0.9mm, CCU ~ GF-GTX (4 bldg. total 2.5Km per block) 54 Two-Wire Bus System Entrance station modules & panels System layout example Audio Module . AUDIO #2 Specifications (GF-DA) #1 1P 1P AIPHONE GF-DP GF-DA Audio panel Audio module Call switch Module Consumption Entrance station Wiring Type of cable 1P AIPHONE H H M AUDIO M GF-BC N Mounting Housing Weight . AUDIO & VIDEO #2 30mA 5 Single-pair cable common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Box and front frame GF-2B,3B and GF-2F,3F Fire-retardant Plastic Approx. 180g #1 1P 1P Specifications (GF-SW) 1P Capacity Lighting Housing Weight 1P GF-1P GF-2P 1-call panel 2-call panel AIPHONE AIPHONE H H M GF-3P GF-4P 3-call panel 4-call panel GF-VBC GF-BC N N M #2 #1 1P 1P GF-SW Specifications (GF-VA) Consumption Entrance station Wiring Type of cable . AUDIO & VIDEO + GF-NS 1P 1P Call switch module N Housing Weight Camera Module 100-call buttons Yellow LED Fire-retardant Plastic Approx. 90g 140mA 5 Two single-pair cables common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Fire-retardant Plastic Approx. 140g N : PS-2410LD, PS-2410LC Specifications (GF-NS) Power source Unit dimensions GF-VA Camera panel Camera module . GF-DP (1) Consumption Wiring Type of cable 7.9 110 AIPHONE Digital name scrolling module 225 95.2 135 (2) GF-NSP GF-NS Housing Weight Housing Fire-retardant Plastic Lighting Yellow LED Weight Approx. 90g 44 GF-10K Digital keypad panel Digital keypad 44 Specifications (GF-10K) 16 135 GF-10KP 16 AIPHONE LCD directory panel LCD directory 320 MULTI-UNIT ENTRY SECURITY GF-VP Specifications (GF-AD) (3) Weight Approx. 90g E N O C L Yellow LED 9 Z P W J G I 3 8 T U Fire-retardant Plastic Lighting 6 K M S B 5 Housing F 2 A H 7 D 4 V 1 Q R AIPHONE 225 Lineup X Y 0 270 GF-AP GF-AD GF-BP Address panel Address module Blank panel 55 DC 24V, supplied by a power supply PS-2410LD, LC 0.07A Two single-pair cables common. 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Fire-retardant Plastic Approx. 150g 16 44 (1) Audio, 4-call (2) Audio, 8-call (3) Audio/Video + Name scroll Entrance station mounting accessories Mounting Front frame & back box . GF-nH GF-3B 42 W GF-DA . GF-nHB W GF-DP GF-3F (4) H H 65 22 (3) GF-3F GF-2B GF-3B 2-module front frame 3-module front frame 2-module back box 3-module back box (5) GF-SW GF-4P GF-2F 85 (2) (1) H W GF-102H/HB 243 155 GF-202H/HB 243 290 GF-103H/HB 338 155 GF-203H/HB 338 290 GF-303H/HB 338 425 (1) Tamper-proof screw & screwdriver (supplied with GF-BC) (2) Module-mounting bracket (supplied with GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance. Back box 1. Hooded surfacemount box Rain hood 3. 200 mm GF-nHB GF-nH (1) 2. (1) 295 mm 25mm 25mm 25mm 44mm W (2) 44mm (2) W 1. Two 2-module back boxes 2. Three 3-module back boxes (1) Joint pipe(x2) (2) Do not recess back box more than 15mm. GF-2B/3B x1 x2 x3 x4 x5 x6 x7 x8 x9 W 110 245 380 515 650 785 920 1055 1190 3. Back box total width (mm) Entrance station components AUDIO (1) 4. 8. AUDIO / VIDEO AIPHONE (1) 4. (1) (2) (3) (4) (5) (6) (7) (8) GF-VA GF-VP GF-DA GF-DP GF-SW GF-4P GF-2P GF-2F GF-2B GF-3F GF-3B GF-BP GF-AD GF-AP GF-NS GF-NSP GF-10K GF-10KP AIPHONE 8. AIPHONE 16. AIPHONE 12. AIPHONE 20. AIPHONE 16. AIPHONE 30. AIPHONE AIPHONE 20. AIPHONE AIPHONE 30. AIPHONE GF-NS GF-10K 40. GF-NS GF-10K 40. AIPHONE AIPHONE AIPHONE 4. 1 1 1 1 1 1 - 4. 1 1 1 1 1 1 1 1 8. 1 1 2 2 1 1 8. 1 1 1 1 2 2 2 2 - 12. 1 1 3 3 2 - 12. 1 1 1 1 3 3 2 2 16. 1 1 4 4 2 2 16. 1 1 1 1 4 4 2 2 20. 1 1 5 5 2 2 20. 1 1 1 1 5 5 3 3 30. 1 1 8 7 1 3 3 30. 1 1 1 1 8 7 1 4 4 40. 1 1 10 10 4 4 40. 1 1 1 1 10 10 4 4 GF-NS, GF-10K 1 1 1 1 GF-NS, GF-10K 1 1 1 1 2 2 - - - - - - - 1 - - 1 - 1 1 - - - - - - - - - - - - - - - - - 1 1 1 1 1 1 1 1 MULTI-UNIT ENTRY SECURITY AIPHONE 12. (1) Number of calling button (2) Camera (3) Audio (4) Call switch (5) 2-module Front frame (6) 3-module Front frame (7) Option (8) Digital name scroll 56 Two-Wire Bus System Residential station Residential audio station GF-1D Apartment station Features Specifications (GF-1D, GF-1DK) Auto-Entry (Auto door strike) Setting required. Call tone from Entrance and Doorbell are differentiated. Power source DC 24V, supplied from 2-wire Bus control unit GF-BC Consumption Total station Wiring 16mA 250 residential stations Single-pair cable common Type of cable 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm Trunk line GF-1DK AUDIO Concierge call apartment station w/Panic call transfer (Photo) GF-1D GF-1D 1P 1P 1P GF-BC N AUDIO & VIDEO AUDIO & VIDEO 1P x 2 GF-1MDK GF-1MDK GF-1MDK 1P x 2 1P x 2 M Residential monitor station Fire-retardant plastic Approx. 370g Specifications (GF-1MD, GF-1MDK) Power source M GF-1MDK M Apartment station DC 24V, supplied from Bus control unit, GF-BC & GF-VBC M Consumption 356mA M Total monitor station150 GF-1MD(K)’s. 1P x 2 1P x 2 GF-1MDK 1P x 2 GF-1MDK GF-1MDK 1P x 2 250 GF-1MD(K)’s w/GFW-VBC, M Expander video control units. 1P x 2 l BUS line (audio); Max. 50 stations l Video line; Max.25 Monitors either via max. 6xGF-4Z’s or Monitor to Monitor. Do not mix two wiring methods on a same trunk line. MULTI-UNIT ENTRY SECURITY DOORBELL BUTTON (option) Housing Weight 1P x 2 GF-1MD Video monitor 10cm direct view flat CRT Wiring Two Single-pair cables common Type of cable 2-conductor cable solid copper & non-braided, polyethylene Unit dimensions insulation, 0.65mm dia.~1.0mm GF-1DK, GF-1D GF-1MDK, GF-1MD dia. 89 60 83.5 60 83.5 210 GF-1MD 200 Concierge call apartment monitor station (w/Panic call transfer) (Photo) dia. Wall-mounting only 60mm or 83.5mm guided M 1P GF-4Z GF-1MDK Mounting Electrical box 1P DOORBELL BUTTON (option) 216 63 Mounting Wall-mounting only Electrical box 60mm or 83.5mm guided Housing Fire-retardant plastic Weight Approx. 1200g 69 Concierge station For either audio or audio/video system Trunk line Specifications (GF-MK) GF-1DK GF-1DK 1P 1P 1P 1P O O Consumption LCD display Wiring Type of cable 50mA Max. 16 letters for names Two Single-pair cables common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Wall-mounting or Desk-top mounting on GFW-S 60mm or 83.5mm guided Fire-retardant plastic Approx. 900g 1P GF-1DK 1P O Mounting 1P Electrical box Housing Weight GF-1DK 1P 1P O GF-MK Concierge station 1P H I 3 B C 5 J N O 7 S K L N O 9 X Y Z Z W U V E F 6 8 T Q R X Y M W 0 GF-MK GF-MK 60 83.5 0 210 T 9 P 4 6 G S 2 E F D K L U V 1 3 B C 5 8 A P 7 Q R M 57 H I J Desk-top stand GF-BC 4 G GFW-S 2 D 1P GF-MK 1 A 1P Unit dimensions 1P N O Panic call switch l Must be used with GF-1DK or GF-1MDK in Concierge station application. 215 69 Bus & Video control units System layout example AUDIO Specifications (GF-BC) MAX.50 GF-1DK 1P 1P Power source MAX.50 1P GF-1DK GF-1DKGF-1DK 1P 1P 1P Mounting Weight MAX.50 1P 1P 1P BUS(AUDIO) Specifications (GF-VBC) 1P 1P 1P 1 2 B A 3 E 4 G H C D 5 I K J N 7S PQ 8 R O 1 Y 4 G 0 2 H I P 6 8 W T U V E F N O Power source DC 24V,m supplied by a power supply PS-2410LD, LC 1,100mA. Single-pair cable common. DIN rail Approx. 260g 9 X Y Z S K L M 7 Q R 3 5 J Bus control unit B C D 9Z WX V A T U F 6 L M GF-BC 1P 1P Consumption Wiring Type of cable GF-1DK 1P GF-1DK 1P DC 24V, supplied by a power supply PS-2410LD, LC 900mA. Single-pair cable common. 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. DIN rail Approx. 450g 0 GF-MK & GFW-S GF-MK #4 #5 #3 GF-BC 1P N 1P H #2 M Consumption Wiring Mounting Weight Specifications (GF-4Z) Wiring Type of cable #1 Two single-pair cables common. 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Approx. 450g AUDIO / VIDEO + GF-NS GF-1MDK GF-1MDK 1P x 2 M GF-4Z 1P x 2 Weight M Wiring distance GF-VBC Video control unit 1P x 2 1P x 2 M 1P x 2 GF-1MDK GF-1MDK BUS(Audio / Video) MAX.6 1 3 2 5 4 6 1P x 2 GF-BC 1P GF-VBC 1P 1Px2 1P 1Px2 1Px2 1P 1P 1P N 1P 1Px2 1Px2(*) N (10) GF-4Z 4-apt. Bus junction unit AUDIO system l Max. 250 Apartment stations l Max. 5 Entrance stations l MAX 100-call panel l Max. 3 Entrance stations per BUS line Audio/video system l Max. 250 Apartment monitor stations l Max. 5 Entrance camera stations l Power supply for five GF-NS’s 1Px2(*) : 1P for Audio & 1P for power supply of GF-NS’s M Optional door strike at each entrance Unit dimensions GF-BC, GF-VBC, GF-4Z 122.5 61 MULTI-UNIT ENTRY SECURITY 1P N N Distance (Diameter of wires) GF-BC to Distribution point 5m (0.8mm) Distrib. point to Entrance station 300m (0.8mm) Distrib. point to GF-1K(farthest) 300m (0.8mm) GF-VBC to farthest GF-1MDK 1 per resid. line 100m (0.8mm), 150m (1.0mm) GF-VBC to farthest GF-1MDK 2 per resid. line 50m (0.65mm), 100m (0.8mm), 150m (1.0mm) GF-VBC to Entrance station(GF-VA, Video) 100m (0.8mm), 150m (1.0mm) GF-BC, VBC/A to ea. Power supply 5m (0.8mm) GF-NS/A to Power supply 300m (0.8mm), 300m (1.0mm) MAW-B to Entrance station 300m (0.8mm) Total wiring distance(R1, R2) 2.5km (0.8mm) 108.5 M Power supply Unit dimensions Specifications PS-2410LD PS-2410LC Power supply PS-2410LD PS-2410LC Power source AC220-240V 120V 164 Secondary output voltage & current 66 95 RD PS-2410LD PS-2410LC DC24V, 1A DC24V, 1A BK RD : Red, BK : Black 58 Two-Wire Bus System Long distance adaptor(Audio) Wiring Sub-Bus No.1 Sub-Bus No.2 Sub-Bus Accumulated total wiring Apartment station distance 2500m max.100/Sub-Bus Farthest Apartment 1P total 250/system 1P station max.150m GF-BC Sub-Bus No.9 1P GF-BC N GFW-LD GFW-LD Sub-Bus No.10 1P GF-BC GFW-LD N GFW-LD 1P 1P GF-BC N 1P Long distance adaptor for audio 1P 1P Common Bus Accumulated total wiring distance 2000m Wiring distance GF-DA-Apartment station GF-MK-Apartment station max. 600m N GFW-LD 1P 1P 1P 1P 1P 1P 1P GF-MK GF-MK GF-BC 1 3 E 2 B F 5 I K L M M PQ PQ V F O 9Z WX T U WX T 8 R Y 3 6 N 7S O 9Z C E 4 H 6 J J L N V G G K U D D Max.5 C 5 I 8 R A A N N 1 2 B 4 H 7S Y 0 0 Max.2 *Communication method : Auto-voice actuation Expanded video control unit Unit dimensions Wiring GFW-VBC 5 VIDEO BUS 2 3 4 GFW-VBC, GFW-LD MAX.6 x GF-4Z's GF-1MDK GF-4Z 1P x 2 1 108.5 6 + B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 + – 122.5 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 IN1 GF-1MDK B1 B2 GFW-VBC Expander video control unit GF-VBC 5 6 Power source VIDEO BUS 4 3 2 1 AUDIO BUS N + – + – B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 Type of cable R1 R2 + – N N DC 24V, supplied by a power supply PS-2410LD, LC 0.9A. Two single-pair cables common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia~1.0mm dia. Standard & Expanded video wiring (w/GFW-VBC) (1) Required when a second GF-1MD is installed in an apartment(s). System layout example 6~11 1. 1~5 6~11 2. 1Px2 1Px2 1Px2 1Px2 1Px2 1Px2 GFW-VBC 1~5 IN 1P 150m 150m 150m 1P N 1P 150m MULTI-UNIT ENTRY SECURITY GF-BC 1Px2 1Px2 1Px2 1Px2 1Px2 1P GF-VBC AUDIO N AUDIO BUS Option MAW-B Auxiliary light control relay for entrance light W-DIN11 DIN mounting rail for GF-BC, GF-VBC, GF-4Z, GFW-VBC GFW-LD N 2 N 1P GF-VBC GFW-VBC GF-BC 1P VIDEO BUS 2 1P 1. Increase wiring distance to the farthest monitor stations 1~5 Standard Bus lines 6~11 Expanded Bus lines 59 Consumption Wiring R1,R2 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 IN5 IN4 IN3 IN2 IN1 61 Specifications N (1) – GF-BC IN VIDEO 2 1P 150m 2. Increase Video trunk lines N VIDEO 1 N AUDIO Two-Wire Electric Lock Door Phone ENTRANCE RESIDENCE 4 DA-4DS 1 Entrance station Lineup Residential station Electric door strike (locally available) DA-2DS DA-4DS 2-call door station 4-call door station DAR-1 Call extension DA-1MD Master station DAW-P Power supply PT-1211D PT-1211C DA-2DG DA-4DG 2-call door station 4-call door station Features Door station mounting plate (83.5mm) m P.106 Wiring 310m / 1.0mma 155m / 1.0mma DA-4DS DA-4DG M DA-1MD 2 2 DA-1MD 2 P P DA-1MD 2 2 P P DA-1MD 2 DAR-1 2 AC15 (1) Communication network DA-1MD DA-1MD DA-1MD DA-1MD DA-4DS, DA-4DG (2) D Electric door 1 E strike 2 D E 3 D E 4 D E M Electronic tone. Direct select ring. ~ ~ D E L L P ~ ~ AC15 ~ ~ AC15 ~ ~ AC15 PT-1211D/C D E P P D E D E P S SE Unit dimensions DA-2DS,G DA-4DS,G (3) 22 DA-1MD 61 175 DA-1MD DA-1MD DAR-1 (1) DA-1MD DA-4DS, DA-4DG 2x2 200 100 SW SW DA-1MD 89 NP 2x2 2x2 MULTI-UNIT ENTRY SECURITY l Two-wire system l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder 2x2 PT-1211D/C (1) Ext. device Relay/Controller : User-optional function(AC18V, 40mA) (2) Door release : Electric door strike or AC 16V, 20d or more (3) When a single common power supply is used Specifications (DA-4DS, G) Power source Power supply Communication Wiring Distance AC 15V. PT-1211D, PT-1211C Press and hold down Button to call. 2 wires, throughout system: PS - Master - Door - Door rlse. PT-1211D/DR ~ Door rlse. 110m(0.6mma) 200m(0.8mma) 310m(1.0mma) PT-1211D/DR ~ DA-1MD 55m(0.6mma) 100m(0.8mma) 155m(1.0mma) 60 Audio Entry Security ENTRANCE RESIDENCE 58 VC-M 1 Entrance station Residential station VC-0M VC-4M VC-6M VC-10M Blank entrance station 4-call entrance station 6-call entrance station 10-call entrance station Power supply PS-1225S PS-1225UL PS-1225 Electric door strike (locally available) VCH-8 VCH-16 8-call add-on panel 16-call add-on panel Apartment station Door release relay m P.104 Other Panels VC-1M,VC-2M&VC-8M m P.106 Features VC-K RY-PA Wiring l Single entry 0 to 10-call panel l Add-on 8 or 16 call panel(s) l VC-K handset, one or two per residence l Directory back illumination l Single or larger panels up to 58 buttons 800m / 1.0mma VC-6M VC-K VC-K 7 MULTI-UNIT ENTRY SECURITY 4+1x3 VC-K M H Q 5 VC-K 7 (1) VC-K 6 VC-K 6 5 4+1x6 2 T VC-6M VC-K VC-K VC-K 1 2 3 4 1 2 3 4 1 2 3 4 B B B Communication network VC-6M VC-K #1 M Electric door strike YL BK 1 2 3 4 1 2 3 4 + + + + + + B + --- 1 2 3 4 B B T L+ L--- #6 H Direct select ring 61 1 2 3 4 (1) 4 common + 6 (no. of apartments) * Terminal 4 for door release T : PS-1225S/UL H : AC transformer Q : RY-PA relay BK: Black(2) YL: Yellow(2) Entrance call panel VC-26MY 26-call entrance station VC-26MT VC-58MT 26-call entrance station 58-call entrance station VC-42MY Lineup VC-BBX 42-call entrance station Wiring Unit dimensions (1) VC-K 2 VC-K VC-K (2) VC-K VC-K VC-M (2) (1) 60 156 83.5 VC-K 1 210 VC-4M 230 1 2 3 4 B 1 2 3 4 + + 1 2 3 4 1 2 3 4 1 2 3 4 YL 68 Q BK B + 80 61 T B + + - 1 2 3 4 B VC-M, VCH VC-26MY VC-42MY VC-26MT VC-58MT VC-BBX B T Added variations (1) Two VC-K stations per apartment. Calling is not available between room stations 1 & 2. (2) Use a local buzzer or bell rated less than 24V DC, 2.5A. T : PS-1225S/UL Q : RY-PA relay YL : Yellow(2) BK : Black(2) H 260 260 260 487 487 – (1) W 186 339 492 186 339 – D 2 2 2 2 2 – H 230 230 230 457 457 264 (2) W 156 309 462 309 309 190 D 68 68 68 68 68 52 Multiple box mounting; Keep a distance of 186mm between two box centers. (1) Front panel (2) Back box Specifications (VC-M) Power source Power supply Communication Wiring Distance MULTI-UNIT ENTRY SECURITY Bz 12V DC, 80mA (intercom). 100mA (lamp) PS-1225S, PS-1225UL Electronic buzzer rings VC-K station(s). (Freq.: 600Hz. approx.) Take (either) handset to reply. Single open channel. 4 common + no.(residences), in loop. VC-M ~ VC-K: 35d looped. VC-M ~ power supply: 4d looped. VC-M to VC-K 330m(0.65mma) 800m(1.0mma) VC-M to PS-1215DIN 40m(0.65mma) 90m(1.0mma) 62 Open Voice Intercom DOOR ROOM 1 1 LEM-1DL Door station Master station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM LE-DA LE-D Sub station m P.69 Sub station m P.69 LEM-1DL Master station Electric door strike (locally available) LE-DL Power supply PS-1225S PS-1225UL PS-1225 m P.106 Door station m P.69 Features Wiring l Single door open voice access control system l Adjustable tarnsmit (front) and tone volumes l AC/DC power supply (1) 300m / 0.8mma LE-D LEM-1DL 2 Communication network 2 M LE-D 1 E 1 E – LEM-1DL Electric door strike 12V AC, 350mA ( M EL EL + – ) H (2) LE-D LEM-1DL 2 M Unit dimensions LE-D 1 E – LEM-1DL 2 1 E Electric door strike EL EL 120 83.5 180 PWR 29 88 143 LE-DA 53.5 Specifications (LEM-1DL) LE-DL 83.5 175 83.5 115 Power supply Communication 10 120 25.5 Wiring Distance 63 H/T (1) Using Electric door strike door release (2) Using door release of other manufacture rated : 30V AC/DC, 1A max. Do not remove shorting link on LE-D. PWR : Power source Power source 116 + – 12~16V AC, 4VA. 12~24V DC, 200mA (24V). AC transformer, PS-1225S, PS-1225UL When called by tone, press TALK to reply. Press door release button to release door, and press OFF for standby. 2 wires, non-polarized (+2 for Electric door strike) LEM-1DL to door 200m(0.65mma) 300m(0.8mma) Open Voice Intercom MASTER SUB 3 LEM 1 Master station Door station Room sub station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM LE-D Sub station m P.69 LEM-1 1-call master LE-A Sub station m P.69 LEM-3 3-call master LE-DA Sub station m P.69 Power supply PS-0602D PS-0602C m P.106 LE-AN Privacy sub m P.69 Features Wiring l Open voice communication l Push-to-talk at master, hands free at remote l LE sub stations: either door station or room sub station l Voice volume control 300m / 0.8mma LEM-1 LEM-1 LE-A 2 Communication network LEM-1 LEM-1 1 E LE-A 1 E – + – LEM-3 LEM-3 300m / 0.8mma LE-D 300m / 0.8mma LE-A LEM-3 2x2 2 LE-A LEM-3 LE-D W LE-AN 2 LE-AN 1 1 E – 2 LEM-1; Tone or voice. LEM-3; Selective call w/tone or voice. Tone and LED from sub 1 E – E Unit dimensions 3 LEM-3 + – ★ Do not remove shorting link on subs. 180 160 LEM-1, LE-A, LE-AN W 1 E – W : PS-0602D, PS-0602C Specifications (LEM) 131 51 143 LE-D 115 83.5 29 116 Power source Power supply Communication 83.5 LE-DA 120 88 53.5 10 Output Wiring Distance 6V DC, 200mA PS-0602D, PS-0602C Sub calls in w/tone and LED, 20 sec. Depress selector button and press or release TALK button. Sub called by tone or voice. Reply hands-free. 350mW output, adjustable 2 parallel wires per sub, non-polarized LEM to sub 200m(0.65mma) 300m(0.8mma) 64 Open Voice Intercom STATION 11 LEF Master station Master station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM LEF-3 3-call master LEF-5 LEF-10 5-call master 10-call master LEF-5W LEF-10W 5-call master w/terminal box 10-call master w/terminal box LEF-10S 10-call master (all call) Power supply PS-1225S PS-1225UL PS-1225 m P.106 Features Wiring l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: PanTilt door/monitor(s), All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA) Communication network Door answering w/selective door release 300m / 0.8mma LE-D #2 LE-D #1 C 2 3 4 5 1 E M E LEF-5 – – YL M LEF-5 Electric door strike Electric door strike H Selective call between inside stations. Answering & releasing door from any inside station Cabling Models LEF-3 LEF-5 LEF-10 LEF-10S Capacity 4 stations 6 stations 11 stations 11 stations Cable 9 wires 11 wires (+5: K1~K5*) 17 wires (+10: K1~K10*) 20 wires (+10: K1~K10*) l K1 ~K10: Control terminals for video, door release. l LEF-3 does not have L terminal. l Door & inside sub stations can ring 2 or 3 LEF masters. l LEF All-master trunk cable=5 (or 6) common + no.of LEF (& subs) 65 LEF-5 13 3 LEF-5 LE-D LEF-5 13 RY-PA's 1 LE-D LEF-5 4 3 C : PS-1225S, PS1225UL Q Q 1 C 3 4 5 1 2 C 4 5 1 2 3 E R Y + – E R Y + – E R Y + – L L L K4 K5 K4 K5 K4 K5 BK H : AC transformer Terminal 4 : for LE-D1, Terminal 5 for LE-D2. YL : Yellow(2) BK : Black(2). T Door station Lineup Room sub station LE-D LEF-20(S)*, 20-call master (photo) LEF-30(S)*, 30-call master LEF-40(S)*, 40-call master *Not available in Europe, Australia, LE-A3 Sub station m P.69 3-call sub LE-A Door release relay m P.104 Sub station m P.69 nor New Zealand All call, music & chime LEW-5 LEF-5 terminal box LEW-10 LEF-10 terminal box LEW-10S LE-DA LE-AN3 Sub station m P.69 3-call privacy sub LE-AN LEF-10S terminal box BG-10C All call, chime & music adaptor m P.69 Privacy sub m P.69 Unit dimensions LEF-3 Intermixed configuration LEF-5, 10, 10S 3 BG-10C LE-D 18 3 LEF-10S LEF-10S LEF-10S LEF-10S 22 22 22 131 143 53.5 LE-A3, AN3 1 1 E E – – Electric door strike H P1 P2 P3 + – YL BK Q Q C 2 3 4 5 6 7 8 9 10 1 E R Y + – L 1 C 3 4 5 6 7 8 9 10 2 E R Y + – L 1 2 C 4 5 6 7 8 9 10 3 E R Y + – L 1 2 3 C 5 6 7 8 9 10 4 E R Y + – L K9 K10 K9 K10 K9 K10 K9 K10 P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 T 3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to wire multiple subs (2 common + 1 per sub). l LE-D call-in chimes on LEF stations. l Only LEF-10S station can transmit all call. l Match door release control terminals (Kn) with door selector #10 with K10, #9 with K9. ★ Remove a shorting link on LE subs. T : PS-1225S, PS1225UL H : AC transformer Q : RY-PA BG-10C 165 1 2 3 4 5 6 7 8 DB DA 11 E R Y + – M 51 55 190 180 M Electric door strike 206 180 LE-D LE-A, AN 160 Wiring COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM RY-PA Electric door strike (locally available) 250 143 77 53.5 Specifications (LEF) Power source Power supply Communication Door release Selector switch Wiring Distance 12V DC, 300mA per LEF station. PS-1225S, PS-1225UL Sub calls in w/(chime) tone & LED, 20 sec. Depress the LED lit selector button. Use TALK/LISTEN switch. Master calls in w/tone or voice (no LED lit). Reply hands-free. To call, depress a selector, and call by voice or tone. Contact: 30V DC, 0.1A (resistance load). Contact: 12V DC, 30mA. 5 wires common + no .LEF (& subs) (all-master system) 2 wires per sub (single-master system). * E to - link remains attached. LE subs: 3 wires with the link removed (when intermixed) Farthest LEF’s 200m(0.65mma) 300m(0.8mma) Specifications (BG-10C) Power source All call transmit All call receive Chime tone transmit Controls Wiring Distance 12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station, and LE-C, CN AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma). 66 Open Voice Intercom DOOR ROOM 3 8 LEF-C Door station Master station Sub station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM LE-D Sub station m P.69 LEF-3C All call sub master Sub station *Not available in Europe LEF-5C LEF-10C 5-call master 10-call master LE-BN* Privacy sub *Not available in Europe LE-C* Sub station w/MUSIC receive volume control *Not available in Europe LE-CN* Power supply PS-1225S PS-1225UL PS-1225 Privacy sub w/MUSIC receive volume control *Not available in Europe m P.106 Features Wiring l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: PanTilt door/monitor(s), All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA) LEF-10C✕7 (20) 1 2 3 4 5 6 7 LE-D 1 LEF-10C LE-D LEF-10C LEF-10C E – LE-B LEF-10C LE-B BK YL Q LE-B H Electric door strike DA – 9 10 11 E R Y + – P1 P2 P3 + – DCIN Power source Power supply Communication LEF-1C LE-B/BN LE-C/CN 15.5 15 20 200 15.5 40 20 208 200 208 238 Output 153 3 3 1 C 2 3 4 5 6 7 8 9 10 1 E R Y + – L P1 P2 P3 1 C 2 3 4 5 6 7 8 9 10 2 E R Y + – L P1 P2 P3 1 2 3 C 4 5 6 7 8 9 10 3 E R Y + – L 1 2 3 4 C 5 6 7 8 9 10 4 E R Y + – L 1 2 3 4 C 5 6 7 8 9 10 5 E R Y + – L 1 2 3 4 5 6 C 7 8 9 10 6 E R Y + – L 1 2 3 4 5 6 C 7 8 9 10 7 E R Y + – L P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 3 1 1 E E 1 E – – – T Specifications (LEF-C) Unit dimensions LEF-5C LEF-10C LE-B/BN✕3 20 20 20 20 BK : Black(2) YL : Yellow(2) Intermixed configuration Internal communication by Selective call. Sub calls in with tone & LED 20 sec. LEF-3C 20 T : PS-1225S/UL Q : RY-PA relay H : AC transformer LEF-10C LEF-10C LEF-10C 20 3 BG10C Communication network 67 LEF-1C LE-B* 3-call master 153 Door release 15.5 15 20 Selector switch Wiring Distance 12V DC, 300mA per station. PS-1225S, PS-1225UL Sub/door calls in w/tone & LED, 20 sec. Depress the LED lit selector button. Depress TALK/LISTEN switch. The LED stays lit while in use. Single talk channel w/OCCUPIED lit. 800mW at 20d (receive). 500mW at 20d (transmit). Contact: 110V AC, 1A. 24V DC, 1A. (on RY-PA output). Contact: 12V DC, 1A. (K terminals) 5 or 6 common + no. all stations Farthest LEF-C’s 200m(0.65mma) 300m(0.8mma) Open Voice Intercom Scheduled to stop production DOOR ROOM 3 8 LEF & MYW-P1L/P3L Door station Door adaptor *Not available in Europe Lineup Master station Door release relay m P.104 MYW-P1L Single PanTilt door adaptor MK-DBC Video door station MYH-CU LEF-10 Video-monitor 10-call master MYW-BA Long distance adaptor m P.26 MYW-P3L 3 PanTilt door adaptor m P.24 Power supply PS-1225S PS-1225UL PS-1225 m P.106 PS-1820S PS-1820UL PS-1820 m P.107 Features Wiring LEF & MYW-P1L l Single PanTilt door & two or more video monitors l Electronic tone call-in l Door selection & reply from any LEF master station l Hands-free video monitoring LEF & MYW-P3L l 3 PanTilt doors & two or more inside monitors l Selective door release activation l Hands-free video monitoring l Audio & video monitoring from any master/monitor station l Surface & semiflush video monitors 75m / 1.0mma 100m / 1.0mma MYH-CU & MYH-CU & MYW-P1L LEF-5 LEF-5 6 6 MK-DGC 2 M A1 A2 U 2 LEF-5 Electric door strike T M Q H YL BK MYH-CU & LEF-5 C 2 3 4 5 1 1 C2 3 4 5 2 1 2 C3 4 5 3 1 2 3 C4 5 4 1 2 3 4 5 C2 + – E R Y + – E R Y + – E R Y + – E R Y + – E R Y + – KA L K5 L K5 L K5 L K5 L K5 E R l Run audio & video wires in separate jacketed cables. Specifications (MYW-P1L) Unit dimensions Power source 83.5 230 83.5 210 83.5 190 Power supply Communication MYW-P3L Wiring 2-gang 155 80 42 155 ON A1 B1 A2 B2 U1 U2 + – T : PS-1225S/UL U : PS-1820S/UL Q : RY-PA H : AC transformer BK: Black(2) YL: Yellow(2) LEF-5 MYH-CU LEF-5 13 13 Door call-in with tone, LED and image. PanTilt viewing. Selective call between rooms MYW-P1L LEF-5 13 A1 B1 A2 B2 U1 U2 + – DA LEF-5 MYH-CU & LEF-5 6 OFF A1 B1 A2 B2 U1 U2 + – Communication network MK-DGC LEF-5 13 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM RY-PA Electric door strike (locally available) 43 50 Distance MYW-P1L: 18V DC, 500mA. 100mA standby. MYH-CU: 0.4A. OA standby. PS-1820S, PS-1820UL (video) Door calls in w/tone & LED, 20 sec, image 45 sec. timed. Depress a lit selector button. Press TALK button to reply. Communication times out in 2-1/2 min. Press MONITOR button to reactivate. 2 parallel wires to door, non-polarized. 6 wires in loop, MYW-P1L to monitors. 6 wires, MYW-P1L to LEF MYW-P1L to door 100m(1.0mma) MYW-P1L to MYH-CU1 75m(35m w/2 monitors)(1.0mma) 68 LE Sub stations & Accessories Weather-resistant sub Unit dimensions LE-DA 88 Sub station 29 116 83.5 175 115 120 Sub station 10 25.5 120 LE-DL Door station LE-DA; 2-gang mounting Room sub Semiflush mount sub *Not available in Europe Unit dimensions 160 LE-A, AN 131 LE-A LE-AN Sub station Privacy sub LE-B LE-BN Sub station Privacy sub LE-C LE-CN Sub station Privacy sub 51 LE-C & LE-CN: w/MUSIC receive volume control 3-call sub All call sub master Unit dimensions Unit dimensions LEF-1C LE-B/BN LE-C/CN 208 LE-A3, AN3 180 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM LE-D LE-DL 83.5 LE-DA 83.5 LE-D 153 143 LE-A3 LE-AN3 3-call sub 3-call privacy sub 15.5 15 20 53.5 LEF-1C All call sub master All call/music/chime adaptor Specifications (BG-10C) Unit dimensions Power source 165 BG-10C 250 BG-10C All call, chime & music adaptor 69 77 All call transmit All call receive Chime tone transmit Controls Wiring Distance 12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station, and LE-C, CN AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma). Handset Intercom MASTER SUB 3 AT-406 1 Master station Sub station Lineup External signaling relay m P.105 AT-406 Boxed set (white color) AT-406P Display pack AT-406B/A Boxed set (charcoal gray) AT-206 AT-306 Master station Sub station Power supply PS-0602D PS-0602C or Batteries m P.106 Features Wiring l Handset master-sub intercom w/2 additional subs (optional) l Battery status LED l Batteries or DC power supply l Buzzer or bell activation (optional) AT-306 AT-206 2 AT-306 2 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM TAR-3 Boxed set AT-306 2 Communication network 1 2 AT-206 W AT-306 x 3 1 2 NP NP 1 2 NP 1 2 + --- W : PS-0602D, PS-0602C Specifications (AT-406) Master calls all the subs simultaneously, while the sub rings the master only. Power source Power supply Unit dimensions Communication AT-206 AT-306 210 83.5 Wiring Distance 80 6V DC, 150mA PS-0602D, PS-0602C or Batteries gAAh (SUM-3) x 4 pcs Press CALL button to ring all subs. Pick up any phone. Sub rings master only. Common talk. 2 parallel wires. non-polarized 2-station set 700m(0.65mma) 1000m(0.8mma) AT-206 to subs 1~3 400m(0.65mma) 600m(0.8mma) 51 70 Handset Intercom STATION 25 TD-H/B Door station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM Sub station Master station TD-1H/B TD-3H/B TD-6H/B 1-call sub 3-call master 6-call master IF-DA Door station m P.34 DE-UR Door station adaptor Power supply PS-1225S PS-1225UL PS-1225 m P.106 Wiring Features l All-master selective ring system l Single-master configuration or intermix w/TD-1H/B l Multi-conductor cable in loop l Multi-talk channels l Door station(s), audio or PanTilt video (max. 2) l Zone paging, with or without talkback l Music source connection. Page pretone cuts out music. (2) Door station communication 230m / 0.8mma 1000m / 0.8mma IF-DA DE-UR 1 1 2 1 2 2 TD-6H/B #1 10 #2 C 2 3 4 5 6 1 C 3 4 5 6 1 2 C 4 5 6 1 2 3 C 5 6 1 2 3 4 5 6 1 2 3 4 C #3 10 #4 10 #5 10 Communication network TD-12H/B TD-12H/B TD-12H/B Paging Speaker TD-12H/B 1 2 1 2 TD-12H/B TD-12H/B IF-DA All-master configuration. Station selector & CALL to ring any other station. Wiring (1) All-master configuration C D D D D D D D + – + – + – + – + – + – + – A B T 1000m / 0.8mma TD-12H/B TD-12H/B C #1 #2 16 #3 16 #11 #12 16 16 15m / 0.8mma #13 16 (3) Single-master configuration TD-3H/B C 2 3 4 5 6 7 8 9 10 11 12 1 D + – 1 C 3 4 5 6 7 8 9 10 11 12 2 D + – 1 2 C 4 5 6 7 8 9 10 11 12 3 D + – T 1 2 3 4 5 6 7 8 9 10 C 12 11 D + – 1 2 3 4 5 6 7 8 9 10 11 C 12 D + – 1 2 3 4 5 6 7 8 9 10 11 12 C D + – l Install main cable of max. condctors allowed for each TD-H/B station model. C : PS-1225S, PS-1225UL Terminal D : Door station 71 TD-1H/B 6 C 1 2 3 TD-1H/B 5 1 C TD-1H/B 4 1 1 C C D T + – + – + – + – Terminal 5 for door 1, 6 for door 2. DE-UR’s should be powered by power supply. Privacy type Lineup Zone page adaptor For desk-top or surface wall mounting, provide TDW-n/A terminal box w/1.5m cord. TD-6Z/A 6-call master station TD-12Z/A 12-call master station TDW-1/A TD-1H/B terminal box TDW-3/A TD-3H/B terminal box TDW-6/A TD-6H/B terminal box TDW-12/A TD-12H/B terminal box TD-12H/B TD-24H/B 12-call master 24-call master TDW-24/A TD-24H/B terminal box full trunk all-master configuration l No break-in call l Zone page(s) in lieu of station(s) Power supply PS-1225S PS-1225UL PS-1225 RY-AC/A External signaling relay m P.104 Specifications (TD-H/B) Power source Power supply Communication (4) Straight paging w/PD-1 (single-zone) PD-1 (1) TD-12H/B 3 (1) T Wiring A G M No. C DC12V + --- + --- TD-H/B + --- Distance T (2) Power source Power supply Communication Wiring Distance PD-2 TD-12H/B (1) 3 T (1) S S V V A G M Power source No. DC12V + --- + --- + --- TD-H/B T T : PS-1225S, PS-1225UL (1) Paging Speakers (2) Talkback speakers Unit dimensions PD-1 PD-2 TD-24H/B 210 83.5 83.5 138 210 TD-1H/B ~ TD-12H/B TD-6Z/A, TD-12Z/A 91 73 100 12V DC, 90mA per channel PS-1225S, PS-1225UL Depress a selector and CALL to ring opponent. 3 + no. TD-Z/A in loop. TD-Z/A stations 650m(0.65mma) 1000m(0.8mma) (PD-1,PD-2) (2) C 12V DC, 70mA per station. PS-1225S, PS-1225UL Depress a station selector 1~12 and CALL (or CALL A) to ring station 1~12 (or A1 ~ A12). Lift handset to reply. Door calls in w/standard or faster(B) intermittent tone, 2-1/2 sec. Pick up and depress the selector assigned. 2 or 3 + no. TD-H/B in loop. TD-1H/B: 4 wires. TD-3H/B: 7 wires. TD-6H/B: 10 wires. TD-12H/B: 16 wires. TD-24H/B: 28 wires. TD-H/B stations 650m(0.65mma) 1000m(0.8mma) DE-UR to door 150m(0.65mma) 230m(0.8mma) (TD-Z/A) (5) Paging with talkback w/PD-2 (single zone) 100 Zone page/talkback adaptor l 7 or 13 identical station, m P.106 Wiring PD-2 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM PD-1 Output Paging & music tone controls Amp. input Music input Tuner output Tape output Talkback gain Environmental noise Paging Wiring PD-1: 12V DC, 300mA. PD-2: 12V DC, 48mA (talkback). 5Kd . Max. 1.5V Treble 12dB at 10KHz. Bass 12dB at 100Hz. AUX or PHONO 100K-500Kd, 0.12~0.5V 17Kd, 0.3V, 1KHz. for full output Audio output: Range 100mV~1.2V, 10Kd or less Low level output: Range 100mV~1.2V, 600d 40dB, 1KHz. at max. volume Less than 80dB (phon) Select an assigned selector # and page w/PAGE button depressed. Release to receive reply 3 wires to TD-H/B via power supply 51.5 83 72 Handset Intercom DOOR Scheduled to stop production ROOM 24 TD-H/B & MY-CU 1 Door station Adaptor *Not available in Europe Master station Lineup COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM Electric door strike (locally available) DE-UR Door station adaptor MK-DBC Video door station TD-12H/B 12-call master MYW-BA MY-CU Long distance adaptor m P.26 Main video monitor MYH-CU Sub video-monitor Power supply PS-1820S PS-1820UL PS-1820 m P.107 PS-1225S PS-1225UL PS-1225 m P.106 Features Wiring l Single PanTilt door integration with three monitors, expandable l Hands-free video monitoring or handset audio / video monitoring 100m / 1.0mma MK-DBC 35m / 1.0mma MY-CU 2 2 Communication network U MK-DBC 1A1 B1 1A2 B2 1A1 B1 1A2 B2 1A1 B1 1A2 B2 U1 U2 + --- U1 U2 + --- U1 U2 + --- 1 2 D1 E D2 C EL EL H Electric door strike TD-12H/B TD-12H/B & MYH-CU TD-12H/B TD-12H/B 16 16 16 DE-UR TD-12H/B & MYH-CU TD-12H/B 16 DE-UR A1 A2 TD-12H/B & MY-CU 6 TD-12H/B 4 M MYH-CU MYH-CU 6 D + --- T C 2 3 4 5 6 7 8 9 10 11 12 1 D + --- 1 C 3 4 5 6 7 8 9 10 11 12 2 D + --- 1 2 C 4 5 6 7 8 9 10 11 12 3 D + --- T : PS-1225S, PS-1225UL U : PS-1820S, PS-1820UL 1 2 3 C 5 6 7 8 9 10 11 12 4 D + --- H : AC trans. Specifications (TD-H/B & MY-CU) Power source PanTilt viewing Unit dimensions Power supply TD-12H/B & MY-CU(MYH-CU) DE-UR 50 100 73 155 73 150 83.5 160 83.5 210 Communication 45 Door release Wiring Distance TD-H/B: 12V DC, 70mA per station. MY-CU: 18V DC, 0.9A max. MYH-CU: 18V DC, 0.4A. PS-1225S, PS-1225UL (TD-H/B). PS-1820S, PS-1820UL (video). Door calls in w/intermittent tremolo and image 45 sec. Rings max. 12 stations. Pick up (any) handset and depress a selector assigned to reply. Image stays on 2-1/2min. Reactivate w/MONITOR button. DC30V or AC250V, 5A (resistance load) 2 parallel wires to door. 6 wires, monitors MY-CU to door 50m(0.65mma) 100m(1.0mma) MY-CU to MYH-CU1 35m(0.65mma) 75m(1.0mma) MY-CU to MYH-CU1-2 17m(0.65mma) 35m(1.0mma) Handset Intercom STATION 90 YAZ-90-3W Phone extension YAZ-90-3W Phone master station Features Wiring l Microprocessor built-in intercom expandable to max. 90 stations on 4-pair cable l Up to 2.9km wiring distance l Communication functions: Camp-on busy, secretary transfer, call transfer l Line-off trouble on one channnel does not affect the other channels 2900m / 0.8mma #10 4P YAZ-90-3W Communication network YAZ-90-3W YAZ-90-3W YAZ-90-3W YAZ-90-3W #39 #40 3P YAZ-90-3W YAZ-90-3W 1 2 1 2 1 2 3 4 3 4 3 4 5 6 + – 5 6 + – 5 6 + – N COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM Power supply PS-2420S PS-2420UL PS-2420 m P.107 N l Remove +,- wires between YAZ stations of different blocks. Within a block locate a power supply in the center of cable run, and make groups of max. 10 YAZ stations. As shown, connect +, - wires from the power supply to each group's initial YAZ station. N : PS-2420S, PS-2420UL Specifications (YAZ-90-3W) Power source Power supply Communication Station to station communication in any pair Unit dimensions Line loop resistance Wiring Total wiring distance 94 83.5 230 YAZ-90-3W 24V DC, 150mA max. 20mA standby. PS-2420S, PS-2420UL per 30-station block. Dial 2-digit station # to ring other station with tone or voice pressing PAGE. Privacy communication on each channel (max. 3). Must not exceed 200d for farthest stations. 20d for power line. 4-twisted pairs (shielded) in loop. Farthest YAZ’s 1900m(0.65mma), 2900m(0.8mma) 84 74 Integrated Security & Communication System MASTER 8 DOOR 120 AX Master station COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM AX-8MV AX-8M 8-call color monitor master station 8-call audio master station AX-16SW 16-call add-on selector AX-8MV, AX-16SW Features l Up to 120 video entrance stations and 8 master stations l All wired on CAT5 (4P), homerun cabling l Total hands-free communication, auto-voice actuation l Press-to-talk operation & optional headset available l Masters available with 3-1/2 inch color TFT LCD l 2 talk channels and 2 video channels l Integrate with CCTV, PC, Access control, PBX system etc. l Two type of All call among masters, Standard & Priority l Audio/visual Monitoring l Scan monitoring-Hands-free audio/visual monitoring l Selective remote control (e.g. door release) • PC remote monitoring & control • PC programmable and event logging Communication network AX-DV AX-8MV AX-8MV AX-DVF PC programming Video signal AX-DM Monitor Calling & communication (w/video from door) Door release 75 *The design and specifications are subject to change without notice for improvement. Preliminary Information Door station Central control unit Color video door station COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM AX-DV AX-DM AX-DVF Audio door station Mullion type Color video door station AX-084C Central control unit, 4 masters and 8 doors AX-248C Central control unit, 8 masters and 24 doors AX-320C Add-on control unit, 32 doors IF-DA Door station AX-DV-P Color video door station w/space for embed proximity reader AX-DVF-P Color video door station w/space for embed proximity reader Power supply PS-2420S PS-2420UL PS-2420 m P.107 IE-JA Door station System Integration Cabling 300m 300m Video signal CAT5 AX-8MV AX-DV Security Integration Software Switch camera System log PC AX System AX-084C CCTV System Remote door release Video signal AX-8MV AX-DVF-P CAT5 CAT5 Calling & Communication with video Door release CAT5 AX-DVF PS24 PS24 Door release history CAT5 Remote door release AX-DM Monitor Card ID RS232C Door release Access Control System Access Control System PC Camera CCTV Switcher Monitor VCR 76 Integrated Security & Communication System Master station Features COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM AX-8MV AX-8M 8-call color monitor master station 8-call audio master station • Up to 8 door stations & 8 master stations • Expandable up to 120 door stations using AX-16SW • 3-1/2 inch TFT color LCD (AX-8MV) • Hands-free, press-to-talk, & optional headset communication available • Available in wall and desk top styles • Master - to - master calling • Standard & Priority All call available among masters • 2 talk channels & communication privacy • 1 Video output (NTSC) (AX-8MV) • Scan monitor, selective remote control (e.g. door release) • External talk switch connection available (e.g. footswitch) • Call extension AX-16SW 16-call add-on selector Door station Audio Features Surface mount Flush mount Surface mount • Vandal-resistant construction AX-DV & AX-DV-P; Surface wall mounting w/aluminum die casting panel AX-DVF & AX-DVF-P; Flush mounting w/stainless steel panel • Space provided to embed proximity reader (AX-DV-P & AX-DVF-P) • Illumination LED's automatically turn on in low light conditions w/color video door stations • Mullion surface mount (AX-DM) AX-DV AX-DVF AX-DM Color video door station Color video door station Audio door station Mullion type Video Image view area • AX-DV, AX-DVF AX-DV-P, AX-DVF-P 65cm IF-DA Door station Flush mount 77 AX-DV-P AX-DVF-P Color video door station w/space for embed proximity reader Color video door station w/space for embed proximity reader 50cm IE-JA Door station 95cm Central control unit Features AX-084C Central control unit, 8 doors and 4 masters AX-248C(photo) Central control unit, 24 doors and 8 masters AX-320C Add-on control unit, 32 doors (max. 3 units) Unit dimension AX-084C, AX-248C AX-16SW 194 63 AX-DV-P 63 63 86 AX-DVF AX-DVF-P IF-DA AX-DM 1-gang 160 295 246 245 195 130 AX-DV 194 88 85 420 426 88 85 175 AX-320C 420 426 175 AX-8M 175 AX-8MV COMMERCIRL & INSTITUTIONAL APPLICATION SYSTEM • Up to 8 doors & 4 masters w/AX-084C Up to 24 doors & 8 masters w/AX-248C Additional 32 doors available w/AX-032C • Homerun cabling w/CAT-5 (RJ-45 connector) to stations • PC programmable • 2 BNC video output (NTSC) w/active video signal • Event logging and remote control available (e.g. PC, Access control, CCTV) • RJ-232 serial output • 19 inch Rack mountable (2U) 98 28 IE-JA 25 146 100 43 2 45 25 22.5 115 100 2-gang 2 45 146 116 10 Components Master station Add-on selector AX-8MV/AX-8M AX-16SW AX-084C AX-248C AX-320C 1~8 1 - 1 - - 9 ~ 24 1 1 - 1 - 25 ~ 40 1 2 1 - 1 41 ~ 56 1 3 - 1 1 57 ~ 72 1 4 1 - 2 73 ~ 88 1 5 - 1 2 89 ~ 104 1 6 1 - 3 105 ~ 120 1 7 - 1 3 Number of door station Central control unit Add-on control unit Note Max. 4 Master stations Max. 4 Master stations Max. 4 Master stations Max. 4 Master stations 78 Commercial Security Intercom MASTER SUB 64 1,024 AI-900 Master station Sub station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM AI-RS150 AI-RS170 Substation, indoor m P.81 Substation, outdoor m P.81 AI-RS160 AI-RS180 Substation, indoor m P.81 Substation, outdoor emergency m P.81 AI-MS900 Master station m P.81 Features l Flexible All-modular construction. Expansion options using interface and function cards. l Sub-to-master communication by voice switch or PTT-activated talk-back. Master-to-master by full-duplex handsets. l Four different substations for specific installation conditions. l Provides a speaker and call button. l Basic conversation plus full range of exchange functions, including; Call forwarding, Scan monitoring, Emergency conference, Conversation recording by way of external equipment, and Paging by way of an external amplifier. l Emergency calls from any substation at a central security control room. l Efficient voice recording at ea. master station. l Used in combination with CCTV, access control, emergency broadcast systems or other security equipment. Communication network (1) AI-MS900 (2) (3) (6) (4) (5) J Calling & Communication (1) Speaker (2) Substations (3) Cordless Phone (4) Access Control (5) CCTV (6) Personal computer. PC Link with programming and monitoring software. 79 Mounting accessories AI-900MF wall-mounting bracket m P.82 AI-PU200 AI-900MF Power transformer unit m P.82 Main frame m P.82 AI-PN100B AI-PU200 rack-mount panel m P.82 Cabling Wiring AI-900MF 1. AI-MS900 (1) AI-900RS AI-900MS CN1 CN1 CN2 CN2 CN3 AI-MS900 C/O (2) (3) 1-(1) CN4 AI-900MF AI-900MF (4) CN3 1-(1) 2. AI-900AL Tel AI-RS150~180 AI-MS900 2-(1) 2-(2) 2C (5) 3. COM1 3-(1) 3-(3) Modem Program PC RS-232C RS-232C 4-(1) 5. AI-900AF l To double the size of the system; Two Tie-line I/F cards are required (after that, add one I/F card for each add’l main frame). (1) Outside line (2) PC (for programming and system maintenance) (3) External paging equipment (4) Substation paging amplifier (5) shielded AMP(1) AMP(2) COM1 INPUT 1P OUTPUT 7-(1) 8. AI-900TI 2P 2P 2P 2P 2. AI-900MF DC24V IN RS-232C AI-900AF CN4 AC-IN CN5 CN8 AMP (16) 7. EXT. AMP. 9. AI-PU200 COM2 4-(2) 1P 1P 1P 15. LIN. 16. LIN. 2C 3-(4) Operation log PC 2. LIN. CN6 RS-232C 4. COM2 3-(2) Modem l Basic system consists of; 4 Master stations, 64 Substations and AI-900MF Main Frame with Interface Cards; Master(1), Telephone(1), Substation(4), Outside line(1), Audio function(1), and power unit(2). 1P 1P 1. LIN. CN5 AI-900AL CN1 AI-900TI CN2 CN1 CN3 CN2 CN4 CN3 CN4 1P 1P Tel 2P CN4 AI-RS150 ~ AI-RS180 6. AI-900RS COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM AI-YC303 AC-IN 24V DC AI-PU200 4 4 ~ (N, L) AI-PU200 ~ (N, L) 1. Master station Interface card 1-(1)To External Record device. 2. Telephone Interface Card 2-(1),(2)To External Recording device 1, 2. 3. Programming PC Connection COM1 3-(1) Via Modem. 3-(2) RS-232C cross cable. 3-(3) Direct connection. 3-(4) RS-232C straight cable. 4. Operation Log PC Connection COM-2 4-(1) RS-232C cross cable. 4-(2) RS-232C straight cable. 5. Audio Function Card (for paging) AMP(1)-(16): Amplifier. 6. Substation Interface Card 1.LIN.-16.LIN.: LINE1-16. 7. External amplifier 7-(1) Paging amplifier. . 8. Tie-Line Interface Card Exchange Interconnection 8-(1) 2C shielded (data line). 9. AI-PU200 Power Transformer. 80 Commercial Security Intercom AI-900 Components Master station AI-MS900 Unit dimensions 74.5 216 Master station Standard indoor substation Features Unit dimensions The AI-RS150 is built with a black resin call button and 14-gauge stainless steel. It can call and converse with the programmed master stations. All substation models are wired with a shielded pair to the Main Frame. 120 2 AI-RS150 Substation, indoor 120 48.5 Indoor vandal resistant substation Features Unit dimensions The AI-RS160 is made with heavy 11-gauge stainless steel and a vandal resistant stainless steel call button. Calls and communicates with programmed master stations or telephones. 3 120 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM The AI-MS900 can initiate or receive calls from programmed substations. Equipped with Pushto-Talk button for simplex communication, vox operated handset, redial and transfer keys, and eight auto-dial keys. Alphanumeric display for caller ID. Two-twisted pair wiring to Main Frame. 213 Features AI-RS160 Substation, indoor 120 57.5 Outdoor vandal resistant substation Features Unit dimensions The AI-RS170 is equipped like the AI-RS160, but with the internal components protected with a synthetic rubber sealant, making it weather resistant. Calls and communication with programmed master stations or telephones. AI-RS170 120 3 Substation, outdoor 120 57.5 Outdoor emergency substation Features Unit dimensions The AI-RS180 is vandal and weather resistant with a red aluminum call button, call assurance LED, and an output to control an external relay. Used for ADA compliance or emergency call applications. 120 3 AI-RS180 Substation, outdoor emergency 120 58.5 Box SBX-2G Surface Mount 2-Gang Stainless Steel Enclosure The SBX-2G is used for surface mounting the RS substations where flush mounting these substations is not possible. 81 Main frame Features Unit dimensions AI-900MF Main frame AI-900MF 443.7 The AI-PU200 has two 20V, 2.5A AC outputs. One unit is required for every two AI-900RS cards installed in the Main Frame. 420 483.6 The AI-PN100B is used to rack mount two AI-PU200 power transformers side-by-side. AI-PU200 AI-PU200 The AI-YC303 is used to wall mount the AI-900MF Main Frame. 160 178 Power transformer unit 288.3 AI-PN100B AI-PU200 rack-mount panel 120 240V 250V 71A OUTPUT TO EX-200 TO FC-210 20V 2.5A 20V 2.5A 68 220V AI-YC303 AI-900MF wall-mounting bracket Interface cards AI-900MS Master Station Interface Card One or two cards per Main Frame. The AI-900MS card provides connection and audio recording outputs for one or two master stations. With two cards installed, four master stations can be connected to one Main Frame. AI-900DI Direct-Select/Master Station Interface Board Used to create a direct-select style master station in place of a digital master. Used with AI-910DI for individual selector buttons and call-in LEDs. Also allows integration with external security systems via AI-910DI board. AI-900AL Telephone Master Station Card One or two cards per Main Frame, used in lieu of AI-900MS card. The AI900AL allows a standard telephone with caller-ID capabilities to be used in place of a master station for communication functions. One or two phones per card, taking the place of an AI-900MS card supporting two master stations. Equipped with audio recording outputs for each telephone connected. AI-910DI Direct-Select Input/Output Relay Board The AI-910DI is used in conjunction with the AI-900DI board to provide relay outputs to control external devices or systems. Each board contains 32 programmable relays, and multiple boards can be used for up to 1024 relays. Use for integration with access control and/or video surveillance systems. AI-900RS, Substation Interface Card Up to four cards per Main Frame. Each AI-900RS card supports up to 16 substations, and up to 64 substations per Main Frame with four cards installed. Connect subs with simple two conductor shielded wire homerun to the Main Frame. AI-900CO C/O Telephone Line Interface Card One card per Main Frame. The AI-900CO allows the connection of up to two outside phone lines, with audio recording outputs for each line. Integration with outside lines allows communication between sub or master stations and standard telephones, cell phones, or pagers. AI-900AF Audio Function Card Connection of external PA amplifier for paging. Up to four inputs from audio sources and 16 outputs to external paging zones. Multiple zones or all zones can be selected and paged simultaneously. AI-900TI Tie Line Interface Card One card per Main Frame in multi-exchange system. The AI-900TI card is used to interconnect multiple Main Frames, expanding the capacity and functionality of the system. Up to four voice paths between Main Frames. COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM The AI-900MF Main Frame can accommodate the following features with the installation of the corresponding circuit cards. Up to 4 master stations or single line phones (2 masters per AI-900MS card; 2 phones per AI-900AL card); up to 64 substations; up to 2 CO lines; paging to 19 zones; tie line connection to additional Main Frame, RS-232 input/output for system programming and event logging. Specifications (AI-900) Power Source Current consumption Communication Modes Serial Ports Operating Temperature System Capacity Master Station Mounting Master Station Wiring Substation Mounting Substation Wiring Wiring Distance: - Master to AI-900MS - Subs to AI-900RS - Between Main Frames 20V AC, 2.5A, provided by AI-PU200; 24V DC provided by external 5A power supply not supplied Aiphone 7A Duplex, half-duplex, and Push-to-Talk RS-232 compliant, D-sub connector ( 9-pin female) 2 ports -Indoor Units 0kC~40kC -Outdoor Units -10kC~55kC 4 master stations; 64 substations per Main Frame Wall or desk mount 2 twisted pairs, homerun to Main Frame Flush mount in 2-gang box 2 conductor shielded, homerun to Main Frame 900m(0.5mma). 1500m(0.65mma) 500m(0.5mma). 800m(0.65mma) 600m(0.5mma). 1000m(0.65mma) 82 Security Window Intercom System SERVICE SIDE 1 PUBLIC SIDE 1 IMU-100 Service Side COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM IMU-100 Main kit IMU-100 IME-100 OU-100 Operation unit IME-100 Gooseneck microphone MU-100 Main unit Power supply PS-2420S PS-2420UL PS-2420 m P.107 Features l First in industry! Using an acoustic tube with noise cancelling microphone l Voice-actuated hands-free communication l Flexible gooseneck type microphone l Optional Mono type headset (a3.5 plug) l Detection sensor switches automatically to communication mode l Separate speaker system using an optional microphone l Paging feature for announcements l Thin shape of the acoustic tube does not obstruct the field of vision l Holes in the barrier glass are not necessary to install Communication network Acoustic tube system 3 Paging speaker ISE-100 2 Barrier glass IAI-100 + IAX-100 1 IMU-100 + IME-100 Service Side 1 2 3 Public Side Voice-actuated hands-free communication Automatically switch to communication mode Paging Separate speaker system 3 Paging speaker ISE-100 2 External speaker + Barrier glass IME-150 3 IMU-100 + IME-100 Service Side 83 Public Side Lineup Public Side Acoustic tube system Separate speaker system Acoustic interface kit ISE-100 External Speaker (locally available) IAI-100 IAX-100 DR-100 Driver unit Sensor + Paging speaker (locally available) IAX-100 Acoustic tube AI-100 Acoustic I/O tube IME-150 Optional microphone Unit dimensions Wiring 20m / (1.2mma) IMU-100 Supplied cable + Cord (3.5m) IME-100 IME-150 160 27 ISE-100 Paging speaker 130 40 210 49 Cord (3.5m) Shielded cable 2 370 2 Shielded cable External speaker + 24 388 2 2 2 206 Mic. AI-100 OU-100 45 Speaker MU-100 Separate speaker system COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM IAI-100 IME-100 63 420 14.5 510 2 34 3800 40 N 24 IAX-100 IME-150 Shielded WHITE RED Shielded WHITE RED – SW + PG OUT C H DC24V + – Connection cord (approx. 3.5m) 13 Specifications (IMU-100) Power source Consumption Operating temperature Communication Headset External speaker Paging speaker N : PS-2420S, PS-2420UL 150 68 W3 N 36 72 3500 Shielded(E) WHITE(-) RED(+) Connection cord (approx. 3.5m) ST-BY SW 23 60 WHITE(C) BLACK(H) DR-100 30 W1 E – + ISE-100 3500 105 C H 115 W2 Separate speaker system 27 84 Supplied cable (approx. 2m) Connector 1000 DC 24 V 120 mA (standby) 780 mA (maximum) 0kC to 40kC Voice-actuated communication Transmit output: 3 W 4 Ω, Receive output: 1.5 W 16 Ω a3.5 plug, Impedance: 32 Ω, Rated input: 40 mW or more, Maximum input: 100 mW or more Impedance: 4 to 8 Ω, Rated input: 3 W or more Maximum input: 6 W or more Impedance: 4 to 8 Ω, Rated input: 3 W or more Maximum input: 6 W or more 84 Master / Sub Intercom MASTER SUB 120 NEM 1 Master station Sub station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NB-L Ceiling sub station NEM-10/C NEM-20/C NEM-30/C NEM-40/C 10-call master 20-call master 30-call master 40-call master NA-NE Sub station NEM-10A/C NEM-20A/C 10-call master NEM-30A/C NEM-40A/C 20-call master 40-call master 30-call master NA-A NA-AN Sub station Privacy sub station Power supply PS-2420S PS-2420UL PS-2420 m P.107 Features Wiring l Lamp memory intercom: Sub’s call-in with tone & light l Press-to-talk or handset with voice actuation l Selective or group call of 10 subs l All Call l Pre-tone sounding at sub, when selected l Optional accessories for health care applications l Expand beyond 40 stations with add-on selectors NEM-40A/C 1 2 3 4 10 EE Communication network NA-A NEM-40A/C NA-A NA-NE NA-A NA-A NA-NE 1. 2. 3. NA-A NA-A 2 2 NA-NE 2 40 E IER-2 NEM-40A/C 2xn 2. NA-A 2 NA-A 2 NA-NE 2 NEM-40A/C 2 x n1 3. NA-A NA-A 2 2 1 E S S PS24 + - 85 2 x n2 2 2 NA-A NA-A NA-AN NA-AN NA-AN RD OG OG/WH BL GR BK 2 NA-NE 1. Run a parallel cable to each NA sub station (in the same conduit). 2. Run a multi-conductor cable(s) throughout system. 3. Run multi-conductor cables up to junction box, then run a parallel cable to each NA sub station. Homerun 1 2 3 4 NE-JA NA-NE 2 N : PS-2420S, PS-2420UL NEM-60A A B C D E 31 32 33 34 Wiring 1. A B C D E NA-NE 1. Selective individual call 2. Selective group call (max. 10) 3. All call 2xn A B C D E A B C D E A B C D E NA-AN NA-AN RD OG OG/WH BL GR BK NA-NE RD: Red OG: Orange OG/WH: Orange/White BL: Blue GR: Green BK: Black IMPORTANT: For NE-JA sub(‘s), homerun wires to secure stable calling and distance of 270m w/1.0mma. Lineup NB-U Call button Music adaptor m P.102 NE-JA Flush sub station NBR-7AS Bathroom pullcord, moisture-resistant NA-T/A(*1) Handset sub station NEM-50 NEM-50A 50-call master 50-call master NEM-60 NEM-60A 60-call master 60-call master NEM-70 NEM-70A 70-call master 70-call master NBJ-20(*2) NBJ-20B(*2) NEM-80 NEM-80A 80-call master 80-call master NEM-90 NEM-90A 90-call master 90-call master NEM-100 NEM-100A Call switching device for NEM-10/C, 20/C m P.102 Call switching device for NEM-10A/C, 20A/C m P.102 100-call master 100-call master NBJ-40(*2) NBJ-40B(*2) NEM-110 NEM-110A 110-call master 110-call master NEM-120 NEM-120A 120-call master 120-call master Call switching device for NEM-30/C, 40/C m P.102 Call switching device for NEM-30A/C, 40A/C m P.102 (*1 ) NA-T/A: Not available in Europe, Australia, nor New Zealand NEW-5 IER-2 Dual master call adaptor m P.103 Call extension m P.104 (*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe Unit dimensions NEM-20/C NEM-40/C N + – N + – 346 446 596 496 NA-A, AN NA-NE NEM-120 NEM-80A • NA-NE 142 NA-NE NA-A NA-AN NAR-6A A B C D E RD OG 115 No. NAR-6A NA-T/A NE-JA OG/WH BLx2 BL GR BK 83.5 No. 116 10 (2-gang) 94 • NB-L NB-L No. E RD BK NAR-6A GR 105 Specifications (NEM-40A/C) Power source Power supply Communication BL OG OG/WH BLx2 1. Power supply requirements One power supply for up to 40-call master Two power supplies for 50- to 80-call master Three power supplies for 80- to 120-call master 2. Adding call button to NA sub stations RD: Red BK: Black GR: Green BL: Blue OG: Orange OG/WH: Orange/White N : PS2420S, PS-2420UL 74 68 160 E E BLx2 185 220 2. • NA-A, NA-AN 176 140 169 N N NEM-20A/C NEM-40A/C 232 N 1+ 1– 2+ 2– 1+ 1– 140 260 1. 260 Wiring COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NAR-6A Output Wiring Distance 24V DC, 45W max. 2.5W standby (NEM-40/C) PS-2420S, PS-2420UL (40-call) Sub calls in w/tone & LED latching at master. Press TALK button to transmit, release to listen, or lift handset. At sub, pretone and voice when selected. Talk hands-free. Press ALL CALL button to activate all sub stations. 500mW max., adjustable. All Call: 6W, 12W. Selectively up to 10 subs w/TALK: 3W 2 wires per sub, non-twisted (1 common + no. Subs) NEM to NA subs 130m(0.65mma) 200m(0.8mma) 86 Master / Sub Intercom MASTER SUB 100 TC-M 2 Master station Add-on selector COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM IER-2 Call extension m P.104 TC-10M TC-20G 10-call master 20-call add-on selector TAR-3 TB-SE External signaling relay m P.105 Sub station Power supply PS-1820S PS-1820UL PS-1820 TC-40G 40-call add-on selector TC-20M TC-40GS 20-call master W/add’l 20-/40-call expansion Features m P.107 Wiring l Expandable internal telephone intercom l One or dual master configuration l Tone & LED call-in, staying on until answered l Additional buzzer at TB-SE (w/relay) l TRANSFER button on TC-M for communication between two TB-SE subs 900m / 1.0mma TB-SE TC-M 2 TB-SE Communication network TB-SE TC-20M TB-SE *TB-SE 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 E E 3 E TB-SE 480 405 330 255 4 E E E E 5 5 6 6 7 7 E E E M C E M C E + 12V T S R S 83.5 210 230 210 72 S TC-20G TC-40G The TC-40GS is equipped with socket to connect the second add-on selector TC-20G or TC-40G. 10 + 12V T S R TB-AD1 1 E IER-2 Specifications (TC-M) Consumption Power supply Communication TC-40GS E l Run 2 parallel wires per TB-SE. Use any E terminal for max. three TB-SE’s. l Do not parallel TB-SE sub wires, or door station wires (in dual-TC-M system). Power source Wiring 8 E E 9.TB-SE IER-2 E 1 TB-SE 2 1 2 1 2 1 2 1 2 1 2 1 2 9 1 2 1 E 80 3 E E 115 555 630 1 E E 10 TB-AD1 TB-SE 2 2 4 E Unit dimensions E U U 2 9 *TB-SE : Sub station for two-master call. TC-10M TC-20M TC-M 3 TB-SE 2 2 8 TC-20M 87 Lineup Sub station Wiring Distance 18V DC, 350mA. 15~16V AC, 50/60Hz, 750mA. 6W. 3W standby. PS-1820S, PS-1820UL, AC transformer. Pick up TB-SE handset. Rings TC-M, w/tremolo & LED, staying. At TC-M, pick up and press a lit selector to reply. 2 parallel wires per TB-SE, non-polarized. TC-M’s 200m(0.65mma) 480m(1.0mma) TC-M~TB-SE 400m(0.65mma) 900m(1.0mma) Master / Sub Intercom DOOR ROOM 1 TC-M & TB-AD10 10 Door station Master station Door adaptor Lineup Call extension m P.104 TB-AD1 IF-DA 1-call door adaptor Door station m P.34 TC-10M 10-call master TC-10MD TB-AD10 10-call master for door release *Not available in Europe TAR-3 10-call door adaptor External signaling relay m P.105 Power supply PS-1820S PS-1820UL PS-1820 TB-ADD 10-way door release adaptor *Not available in Europe m P.107 Features Wiring l Single or multiple audio door communication, expandable l Optional selective door release control IF-DA TB-AD10 TC-10MD TB-ADD Electric door strike 2 2 (x10) Communication network NP PT 11 IF-DA TC-M+TB-AD10 1. 2. 1 2 D1 1 2 D2 1 2 D3 1 2 D4 1 2 D10 TB-ADD 10. Electric door strike ( 10) M Pre-tone sounding or mute selectable at TB-AD10. 1 2 3 4 1 2 3 4 D1 D2 D3 D4 D1 D2 D3 D4 10 10 D10 DE D10 DE 12V 12V T R T R E E E TB-AD1 TB-AD10 E PRE-TONE ON OFF TB-AD10 2 TB-AD10 3 74 42 150 2 T TC-20M TB-AD1 L3 L3 Electric door strike TC-20M + TC-20G TB-AD10 1 97 Wiring IF-DA L2 L2 L10 L10 U 230 83.5 140 IF-DA L1 L1 L4 L4 E Unit dimensions COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM IER-2 2 10 5 2 2 10 IF-DA 10 Multiple TB-AD10 installation; Add a power supply for TB-AD10 #3 or after. 1 2 1 2 N + – T R 2 U : PS-1820S, PS-1820UL Specifications (TB-AD10) U TB-AD1 5 (x3) TB-AD1 TB-AD1 2 19 20 + – T R 2 Wiring TC-20M IF-DA IF-DA Power source Door capacity Communication IF-DA Distance TB-AD10: 12V DC, supplied by TC-M. 10(TB-AD10). 1(TB-AD1). Door calls in w/tremolo & LED 40 sec. Pick up and depress LED lit selector. Pretone sounds at door, or silenced. 2 parallel wires to door, non-polarized. 4 common + no. doors, TC-M to adaptor. TC-M to TB-AD10 65m(0.65mma) 150m(1.0mma) TB-AD10 to IF-DA 150m(0.65mma) 360m(1.0mma) 88 Master / Sub Intercom DOOR Scheduled to stop production ROOM 1 TC-M & TB-ADM10 10 Door station Master station Door adaptor Lineup Video monitor COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM MYW-BA Long distance adaptor m P.26 TC-10M MK-DBC 10-call master Video door station TC-10MD TB-ADM10 10-call master for door release 10-call PanTilt adaptor MYH-CU IER-2 Video-monitor Power supply PS-1820S PS-1820UL PS-1820 Call extension m P.104 TAR-3 External signaling relay m P.105 TB-ADD 10-way door release adaptor m P.107 Features Wiring l Max. 10 PanTilt video door communication l Optional selective door release control l Manual or auto video monitoring MYH-CU MK-DBC 2 (x10) 6 TB-ADM10 TC-10MD TB-ADD NP Communication network A1 A2 1A1 1A2 A1 A2 2A1 2A2 A1 A2 3A1 3A2 A1 A2 4A1 4A2 A1 A2 10A1 10A2 1. MK-DBC MYH-CU 2. 10. MYH-CU Electric door strike ( 10) TB-ADD 1A1 1A2 U1 U2 U1 U2 D1 D2 D3 D4 D1 D2 D3 D4 10 E D10 DE D10 DE L1 L1 L2 L2 L3 L3 L4 L4 CN7A CN2 L10 L10 Electric door strike PS18 CN9 CN9 COAX OPTION b b PS18 M PRE-TONE ON OFF Time lapse VCR control l Each TC-M & TC-G has 2 sockets for plug-in connectors from TB-ADM10 with supplied junction cables. On TC-M, PanTilt selector # terminals must remain vacant. U : PS-1820S, PS-1820UL PanTilt viewing Unit dimensions Specifications (TB-ADM10) 92 MYH-CU : 2-gang mounting 210 83.5 MYH-CU 230 TB-ADM10 195 1A1 1A2 1 2 3 4 Electric door strike 2 PT 11 CN1 CN11 TC-10M & TB-ADM10 89 *Not available in Europe 155 50 Power source 18V DC, 700mA. Power supply PS-1820S, PS-1820UL PanTilt door capacity10(incl. IE/IF audio). Call-in 40 sec. timed. MYH-CU image timer 2-1/2 min. timed. Auto-scan timer 60 min. max. w/duration 10, 20 or 30 sec. Press MONITOR 2 sec. to initiate. Wiring 2 parallel wires to door, non-polarized Distance TB-ADM10 to door 50m(0.65mma) 100m(1.0mma) TB-ADM10 to PS 5m(0.65mma) 10m(1.0mma) Market-Com STATION 60 MC-60/4A Market-com station *Not available in Europe Market-com adaptor Lineup Paging speaker MC-A/A Zone page adaptor MC-60/4B Market-Com desk station *Not available in Australia nor New Zealand Power supply PS-2420S PS-2420UL PS-2420 m P.107 MC-60/4A Market-Com station Features Wiring l Max. 60-station paging & communication system l Selective 4 talk channels with in-use LED’s l Conference call among 3 stations l Music cutout during paging l Reinforced modular coil cord MC-60/4A 10 3 7 2 7 S 1 7 7 1 7 2 7 3 7 MC-60/4A 10 7 #1 #2 MC Communication network 7 7 7 7 7 7 7 7 #3 #4 MC-A/A A G M (1) MC-60/4A MC-60/4A (2) Ch.1 Ch.4 (1) Paging (2) Select a channel 1~4 paged, and communicate. Unit dimensions MC-60/4A COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM w/built-in transformer (locally available) #1- 10 3 2 1 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1/+ 2 3 4 5/– 6 7 N MC-A/A 1 2 3 10 -#2 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 #3~#6 143 83.5 234 Station blocks #1~6 of max. ten MC-60/4A’s N : PS-2420S, PS-2420UL Specifications (MC-60/4A) 91 90 51.5 94 Specifications (MC-A/A) Power source Amp. input Music soursce output 24V DC, PS-2420S, PS-2420UL AUX 10Kd, 0.3V~0.5V Range 100mV~1.2V, 10Kd or less Power source Power supply Communication Talk channel Wiring Cable specified Distance 24V DC, 70mA max. (in page). PS-2420S, PS-2420UL at MC-A/A. Pick up and depress channel selector 1~4 and page w/PAGE button. Called party picks up and presses lit LED channel button. 4 and a separate paging channel. 7 wires in loop, non-twisted. Line capacitance less than 25pF/30cm. MC-A/A to MC-60/4A(*) 500m(0.65mma) 750m(0.8mma) Total wiring distance 1500m(0.65mma, 0.8mma) (*) MC-A/A to farthest MC-60/4A, or between two farthest MC-60/4A’s of different blocks. 90 Mid-Power Intercom MASTER SUB 3 MP-S 1 Master station Sub station Lineup COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM N-EA* NBZ-M* Surface round frame Flush square frame NP-W* Surface mount box for NP-B AS-3N Sub station MP-1S MP-3S 1-call master 3-call master 8d horn speaker locally available Call button Power supply PS-1225S PS-1225UL PS-1225 AS-3A NP-B Sub station Flush call plate m P.106 *Not available in Europe Features Wiring l 1 or 3-call mid-power intercom, 2.5W powered l Incorporates subs either in console, ceiling mount or 8d horn for maximum output l Hands-free reply from sub MP-1S 150m / 0.8mma 2 MP-1S 8ohm 2 NP-B 1 E T Communication network 8ohm BL + - RD MP-3S MP-1S MP-1S MP-3S 8Ω 2x3 AS-3A 2 AS-3N 2 2 8ohm NP-B 1 E MP-3S AS-3A 2 E AS-3N NP NP 1 E NP-B BL ★ 8Ω MP-3S NP-B 3 E NP-B T NP + - BL 8ohm RD 8d Horn w/talkback reply l For 8d horn without NP-B, install a 33MFD, 25V NP capacitor on No. line. BL : Blue(2) RD : Red(2) ★NP-25V Capacitor T : PS-1225S, PS-1225UL Unit dimensions MP-1S MP-3S 43 78 91 83.5 169 83.5 Power source Power supply Communication 177 148 Specifications (MP-S) AS-3A 142 41 Output Output impedance Wiring 74 Distance 12V DC, 1A. PS-1225S, PS-1225UL Sub calls in w/tone (& LED 20 sec. on MP-3S). Press sub selector and TALK to transmit, and release to listen. 2.5W at 1KHz. 8d 2 parallel wires per sub, non-polarized. *Do not make E wires common. MP-S to sub 100m(0.65mma) 150m(0.8mma) High-Power Intercom MASTER SUB 10 AP-M 2 Master station Sub station Call button Lineup NP-W* NP-B Flush call plate AS-3N Sub station NBZ-M* Flush square frame for AS-3N AP-5M 5-call master AP-10M 10-call master (Photo) N-EA* Surface round frame for AS-3N AS-3A AP-1M Sub station 1-call master *Not available in Europe Features Wiring l 10 watt-powered paging & communication system l Selective all call to 5 subs l Single or dual-master configuration l 8d or 16d horn speaker with talkback 2 2 NP-B 2 AS-3N Communication network 7 (1) AP-10M (1) AP-10M 1 E NP-B AS-3N 3 E 4 E 4 E 5 E 5 E C E 10 E 10 E R C E R GND GND (1) 8d horn Unit dimensions 140 BL RD BL 1 E RD 240 253 AP-5M, AP-10M 1 E 3 E NP-B NP25V 33µF AP-10M 2 E AS-3A 140 P. 2 E NP-B AP-1M 3P(2P+1) AP-10M AS-3A COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM Surface mount box for NP-B BL : Blue(2). RD : Red(2). 276 196 41 74 NP-B 180 169 142 Power source Consumption Communication 115 AS-3N 83.5 AS-3A Specifications (AP-M) 15 47.5 70 16 27 Wiring Distance 110~125V, 127V, 230V, 220~240V AC, 50/60Hz. 45W. 6W standby. Sub calls in with tone & LED, 15 sec. Depress selector and use Talk/Listen switch. All call selectively to max. 5 subs. Max. 10W transmit, adjustable. 300mW receive, adjustable. 1 twisted pair per sub, non-polarized 3 pairs (5), masters. AP-M to sub 150m(0.65mma) 230m(0.8mma) 92 Nurse Call MASTER SUB 80 NHX 1 Master station Add-on selector Central control unit COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NHR-SP Duty station NHX-80X Central control unit NHX-50M 50-call master station NHX-30G Zone light 30-call add-on selector Plugs into NHX-50M NHR-30K 30-call add-on trunk card NHR-3A-4 Power supply PS-2420S PS-2420UL PS-2420 m P.107 Features l One master, up to 80 sub stations. Single and dual patient stations l Multi-station capability per patient room l Three types of call-ins from patient stations: Routine call, Bathroom call & Cord-out trouble call, identified by tone & blinking LED (w/priority according to urgency and time of call) l NHR-3TS Common Area Call station is used for common area bathroom call or staff call (urgent) l Optional zone light (max. 4) 4-zone call light Communication network NHR-4A/A Duty station NHR-SP NH-2SA/A NHR-7A Tone & LED Communication 1. At NHX-50M master, when called by a bedside sub, either lift handset or press TALK once to establish talk channel. To initiate a call, press the selector button of the sub. At the sub, pretone sounds and TALK is lit green. Corridor and zone lights do not turn on. To silence the tone, press TONE-OFF button. Tone will resume after 90 seconds or when new call is placed. 2. Corridor lamp & Zone 1~4 light turn on with any type of call placed by sub station area. When talk channel is established, two lights will turn off. 3. A call from NHR-3TS is of the same level as Urgent bathroom call. (no verbal communication) Patient rooms NH-1SA/A Blinking NHR-4A/A • Routine call, Urgent bathroom call or Cord-out trouble call Tone & LED NHR-4A/A NH-2SA/A NHR-7A Common area restrooms NHR-7A NHX-50M NHX-30G (up to 3) NHR-3TS (max. 4) 1 2 NHR-3A-4 Lights on for any call NHR-7A 3 4 • Urgent bathroom call NHR-3TS • Urgent staff call 93 Duty station Staff call area NHR-7A (up to 3) *Not available in Europe, Australia, nor New Zealand Sub station Corridor lamp NH-2SA/A NHR-3TS NHR-4A/A Single-jack bedside sub station Dual-jack bedside sub station Calling zone light Corridor lamp w/red & white lamps NHR-8A NHR-DP NHR-7A NHR-7A Bedside call switch Dummy plug Staff call switch Bathroom pullcord Call tone & light annunciation TYPE OF CALL Wiring TONE LIGHT Single chime, every 6 sec. — Blinking, every 2 sec. ‘CALL’ steadily lit White lamp steadily lit Routine call At NHX-50M (& at Duty station) At Bedside sub At Corridor lamp — NHR-4A/A Sub trunk line (max. 10 subs) NH-1SA/A 3P NHR-4A/A NH-2SA/A NHR-7A 3 NHR-4A/A Single chime, every 2 sec. At Bedside sub — At Corridor lamp — Double blinking, every 1.8 sec. ‘CALL’ steadily lit & on pullcord Red lamp steadily lit NHR-7A 20m NH-1SA/A 3 3 3P NHR-7A 3 Cord-out trouble call NHR-7A 3 3 Single chime, every 0.5 sec. At Bedside sub — At Corridor lamp — Blinking fast, every 0.4 sec. ‘CALL’ steadily lit & on pullcord White lamp steadily lit 3 2 NHR-7A 3 3P 3P 1 5 1 2 1 3 4 5 PS 2 1 3 4 NHR-3TS in common area Staff call (urgent) — Red blinking (2 lamps) White blinking (one lamp) 5m PS PS 2 1 3 5 PS 5 4 2 5 50m 3 4 (max.4) 20m 5P — 20m ...... NHX-80X CCU Bathroom call (urgent) 20m NHR-7A 3 20m NHR-3TS 3P At NHX-50M (& at Duty station) 50m up to farthest sub. Max. 100m per block. 3P Urgent bathroom call or NHR-3TS NH-1SA/A 3 3 At NHX-50M (& at Duty station) NH-1SA/A 3 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NH-1SA/A 20m NHR-SP NHX-50M/NHX-30G PS : PS-2420S,UL Line-off trouble at NHX-50M Line-off at bedside sub Line-off at Duty station Slow buzzer, intermittent Faster buzzer, intermittent Lit 0.2 sec., every 2 sec. No light Sub trunk line: 6 wires (3P). 4P with NHR-3A-4 light included. Each zone requires a separate common wire from NHX-80X. Use twisted pairs with an overall shield, low capacitance, 0.65mm dia., solid conductors. (Rated capacitance level of wire: 25pF/30cm or less) 94 Nurse Call NHX Components Central control unit Central control unit Specifications (NHX-80X) Controls the NHX-50M and up to 80 sub stations. 1 ~ 8 trunk lines of up to 10 stations per trunk connected inside CCU. (3 pairs, or 4 pairs if zone light is installed). 5 pairs to Master station. Terminates in CCU Zone light (4 in loop), Duty station, and power supplies(2). After installation, the NHX-80X must be initialized. During use, turn power switch off and back on to reset. Install NHR-30K Expansion Trunk Card when NHX-30G is used. Power Source Power supply Station capacity Calling Communication Call-in priority Warning tones Wiring Unit dimensions NHX-80X Wiring distance 460 NHR-30K 30-call add-on trunk card Mounting 340 98 24V DC, 4A max. 2 pcs PS-2420S, UL power supplies 50 sub stations (max. 80 with NHX-30G & NHR-30K). Routine call, Urgent bathroom call & Cord-out trouble call. Up to 5 calls can be displayed on NHX-50M. Single and private talk channel. Press-to-talk or handset voice-actuation (1) Cord-out trouble call, (2) Urgent bathroom call and NHR-3TS common area bathroom call or staff call, (3) Routine call. Subs’ call-ins on standby connected according to urgency level and time of call. (1) Line-off trouble at Bedside or NHR-3TS sub & Duty station. (To stop tone on the Duty station, plug in, 2-pin jumper to CN104 in CCU).(2) 90 sec. elapse timer: Call tone goes up to HIGH level.(3) 90 sec. off-hook timer: Steady tone will notify that handset is off-hook. 3 (or 4*) twisted pairs, CCU to Sub trunks 1~8. (*when zone light is installed) 5 twisted pairs, CCU to NHX-50M. 6 wires (parallel), CCU to NHR-SP. 5 wires (parallel), CCU to NHR-3A-4. Use twisted pairs with an overall shield, low capacitance, 0.65mm dia., solid conductors. (Rated capacitance level of wire: 25pF/30cm or less) CCU to Sub (farthest) 50m(0.65mm) Sub trunk line 100m(0.65mm) CCU to NHX-50M 20m(0.65mm) CCU to Duty station 20m(0.65mm) CCU to Zone light 50m(1.0mm) CCU to PS-2420UL 5m(1.0mm) 3-gang wall-mounting. Or inside Electrical Enclosure with secured door (Provide a suitable, non-combustible mounting surface). Master station Features NHX-50M 50-call master station Unit dimensions NHX-50M NHX-30G 210 Extremely compact 50-call desk console. Open voice communication with TALK button, or handset (voice-actuated). When called, simply press TALK or pick up handset to establish channel. Otherwise, press TONEOFF button and go to calling location. To initiate a call, press a selector button first. NHX-30G is a 30-call add-on selector. Plugs itno NHX-50M. 210 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NHX-80X Features 280 94 90 58.5 Specifications (NHX-80X) Wiring NHX-30G 30-call add-on selector Distance 10-pin plug in connector (to NHX80X). Provided with preset volume controls. Can verify connection of all sub stations. Install within 20m from CCU. Duty station Features Specifications (NHX-80X) Acknowledges any station call with tone and blinking LED. Go to the NHX-50M. Press TONE-OFF and identify the caller at Master station. Mounting Wiring Unit dimensions 120 NHR-SP NHR-SP Duty station 116 95 46 2-gang semi-flush mounting. CN1 (6 pin) to NHX-80X. When NHRSP is installed, unplug Connector from CN104 on NHX-80X. Bedside sub station NH-2SA/A Single-jack bedside sub station Dual-jack bedside sub station Specifications Bedside station for calling and communication. Used with NHR-8A call cord. When call button is pushed, iCALLj LED is lit red. When master replies, green iTALKj LED is lit. Press CANCEL to reset the call. When NHX-50M calls in, pre-tone sounds and iTALKj LED is lit green. Dummy plug (NHR-DP) Plugs into jack unused on bedside sub stations. Mounting Wiring 2-gang semi-flush mounting Sub Nos. 1 ~ 10 setting on SW1. CN1 (6 pin) to sub trunk line. CN2 (8 pin) for NHR-7A, NHR-4A/A & zone light. Unit dimensions 120 NHR-8A NHR-3TS NHR-3TS 120 NH-1SA/A, NH-2SA/A Bedside call switch Calling zone light 116 46 116 28 45 NHR-DP Dummy plug Bathroom pullcord NHR-7A Staff call switch Mechanically locked calling device, used to place an urgent bathroom call from a patient room, common area bathroom or staff call location. Cannot be used alone, and must be used with NH-1SA/A, NH-2SA/A, or with NHR-3TS common area call station. Provides dry closure contact. Master-CALL LED indicates call placed. Ratings DV 24V, 100mA (min. 5mA or more). Unit dimensions NHR-7A 115 Features 71 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NH-1SA/A Features 10 Specifications Wiring Distance Single-gang semi-flush mounting. 3 wires to patient station or NHR-3TS. Corridor lamp When a call is placed, the NHR-4A blinks red or is steadily lit white. Ratings: DC 24V (or more), 200mA max. Unit dimensions NHR-4A /A 120 Features 70 NHR-4A/A 27 Specifications Corridor lamp w/red & white lamps Wiring Distance Single-gang semi-flush mounting. 3 wires to Bedside sub station. Zone light NHR-3A-4 4-zone call light Unit dimensions NHR-3A-4 46 Zone lamp turns on when any call is placed on the system, indicating which zone has a call placed. Up to 4 zone lights can be installed in one system. Install one PS-2420S, UL for every 2 zone lights. Lamp ratings: DC 24V ~, 200mA. 120 Features 438 96 Nurse Call NHX-80X COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM 51 52 53 54 55 56 A NH-1SA/A NH-1SA/A 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ZL ZL ZL 11 12 13 14 15 16 Z3 Z1 61 62 63 64 65 66 21 22 23 24 25 26 71 72 73 74 75 76 31 32 33 34 35 36 Z4 81 82 83 84 85 86 NH-1SA/A D 1 2 NHR-3A-4 1 3 2 3 4 OR YL RD GR BL RD 4 NHR-3A-4 NHR-3A-4 1 1 2 3 2 + --- + --- G G PS-2420S WL WL RL E RL E TC TL E TC TL E 2 NHR-4A/A RD OG R1 R2 ZL LC R3 R4 RC E PR GY ZL LC NHR-7A YL BL GR BL PS-2420S NHX-50M DS1 DS2 DS3 DS4 DS5 DS6 A Patient rooms w/a single bedside sub station B Staff call (corridor) C Bathroom call (common area) D Patinent rooms w/multiple bedside sub stations E Corridor lamp NHR-4A/A 1 : Two white lamps 2 : One red lamp NHR-4A 2 is required only when NHR-7A bathroom pullcord is installed in a single and common bathroom. 97 1 2 3 4 5 6 BR OG RD OG 6 (parallel) NHR-SP 1 2 3 4 5 6 41 42 43 44 45 46 4 OR YL RD GR BL RD OR YL RD GR BL RD OR YL RD GR BL RD 3 4 NH-1SA/A Z2 1 NHR-4A/A NHR-3A-4 NH-1SA/A S1 S2 S3 S4 S5 S6 PS24 A+ A- PS24 B+ B- M1 M2 M3 M4 M5 M6 M7 M8 M9 M10 NHX-30G M1 M2 M3 M4 M5 M6 M7 M8 M9 M10 PS24: PS-2420S, PS-2420UL, PS-2420 Wire color identifications NHR-3A-4 OR: Orange (Zone 1) YL: Yellow (Zone 2) RD: Red (+) GR: Green (Zone 3) BL: Blue (Zone 4) RD: Red (+) Zone light relay makes contact. NHR-4A/A BR: Brown OG: Orange RD: Red OG: Orange NHR-7A YL: Yellow BL: Blue GR: Green BL: Blue NH-1SA/A BR: Brown RD: Red OG: Orange YL: Yellow GR: Green BL: Blue PR: Purple GY: Gray NHR-3TS BR: Brown RD: Red OG: Orange YL: Yellow GR: Green BL: Blue PR: Purple B NH-1SA/A C NHR-3TS NHR-3TS NHR-7A WL RL E TC TL E ZL PR GY 1 2 3 4 5 6 BR RD OG YL GR BL PR BR OG RD OG YL BL GR BL NHR-4A/A 1 2 3 4 5 6 WH TC1 TL1 BR RD RD E OG TC2 TL2 YL GR BL NHR-7A YL BL GR BL NHR-7A ZL TC1 TL1 BR RD E OG TC2 TL2 ZL NH-1SA/A NH-1SA/A 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 WL WL WL WL RL E RL E RL E RL E TC TL E TC TL E TC TL E TC TL E ZL LC PR GY ZL LC PR GY YL BL GR BL BL PR NH-1SA/A PR GY YL BL GR BL YL GR NH-1SA/A ZL LC NHR-7A YL BL GR BL YL BL GR BL ZL LC COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM 1 2 3 4 5 6 Multi-station patient room applications Multiple NH-1SA/A and NH-2SA/A bedside sub stations can be installed within a patient room, observing the following conditions; 1. Max. 6 bedside sub stations may be connected per room for max. 12 calls (when NH-2SA/A stations are used). 2. A corridor lamp inside (NHR-4A) must not be connected with more than 4 bedside sub stations. 3. Due to the above, install two NHR-4A/A corridor lamps when more than 4 sub stations are in one room, i.e. two WHITE lamps used in one NHR-4A/A, and one RED bulb used in the other NHR-4A/A. 4. NH-1SA/A and NH-2SA/A station numbers must be programmed in numerical order and connected to the same subs trunk line. 5. NHR-7A bathroom pullcord is optional. 98 Nurse Call MASTER SUB 120 NEM 1 Master station Sub station COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NEM-10/C NEM-10A/C 10-call master 10-call master NEM-20/C NEM-20A/C 20-call master 20-call master NA-A Sub station NA-AN Privacy sub station NEM-30/C NEM-30A/C 30-call master 30-call master NEM-40/C NEM-40A/C 40-call master 40-call master Features Power supply PS-2420S PS-2420UL PS-2420 m P.107 Wiring l Lamp memory intercom: Sub’s call-in with tone & light l Press-to-talk or handset with voice actuation l Selective or group call of 10 subs l All Call l Pre-tone sounding at sub, when selected l Optional accessories for health care applications l Expand beyond 40 stations with 50-120-call master stations NA-A/AN NA-NE NA-A/AN 2 2 2 2 2 2 NB-L 1+n 1+n 2 NBY-1A (1) 2 (2) 2 NBY-4A NBY-4A 2 NEM-40A/C (3) (1) (2) (2) NB-L NA-A NA-A NA-A NA-A (3) NBR-7AS-S (4) (5) (1) All call for instant transmission to all subs (2) Selective call up to 10 subs or individually (3) Subs call-in w/tone & LED staying with corridor light on (4) NBR-7AS-S: Bathroom pullcord in a patient room (5) Multi-substation patient room 99 NAR-2A l 1 + n = 1 common + no. of Subs NEM-40A/C NEM-40A/C NBR-7AS 2 3 2 Communication network NBR-8A 3 Lineup NAR-6A NBY-4A NAR-3 Call switching device for NEM-10/C, 20/C m P.102 Call button Corridor call light Round corridor light NBJ-40(*2) Call extension m P.104 NB-L NE-JA Ceiling sub station Flush sub station NR-4AS13(*1) B Call switching device for NEM-30/C, 40/C m P.102 NB-U Music adaptor m P.102 NBJ-20B(*2) NA-NE Sub station NA-T/A(*1) NEW-5 NAR-2A NBY-1A Metal jack for bedside call switch Dual master call NBJ-40B(*2) adapto Call switching m P.103 device for NEM-30A/C, 40A/C m P.102 Call reset button NBR-8A Bedside call switch Handset sub station NBR-7AS-S(*1) NBR-7AS Bathroom pullcord, moisture-resistant (*1 ) NA-T/A, NBR-7AS-S, NR-4AS13: Not available in Europe, Australia, nor New Zealand Wiring Call switching device for NEM-10A/C, 20A/C m P.102 B (*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe Wiring NEM-40A/C NEM-40A/C E 1 2 3 4 5 9 10 E A B C D E NBY-4A 1 2 3 4 5 6 7 8 9 10 NA-NE NA-A RD BK GR OG OG/WH BL NBY-4A NBR-7AS-S (SOP) N + – RD BK GR BL OG (2) NBY-1A BL BLx2 BLx2 E RD BK GR BL OG OG/WH RD BK GR BL NBY-1A NBY-4A NBR-7AS x2 BLx2 NBY-4A NAR-2A 11 12 13 14 15 16 17 18 19 20 NBR-7AS IER-2 S S X NAR-2A NB-L 39 40 1 E RD BK GR BL OG OG/WH BL NAR-2A E 31 32 33 34 35 (1) NB-L NBY-4A BLx2 NAR-2A COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NBJ-20(*2) IER-2 NBR-8A Health care application l Up to three NBR-7ASs can be connected in parallel. RD : Red BK : Black GR : Green OG : Orange OG/WH : Orange/White BL : Blue N : PS-2420S, PS-2420UL PS24 + — A B C D E (3) BL NR-4AS13 (SOP) BL BLx2 A B C D E A B C D E A B C D E (4) NA-A, NA-AN NAR-2A Bathroom pullcord within a patient room (1) NBR-7AS-S: Call-in from NBR-7AS-S cannot be cancelled with NAR-2A Call reset button. Press on upper end of Call button on NBR-7AS-S to release the call. (2) Cut GREEN wire. Multi-substation patient room (3) NR-4AS13: NBY-4A corridor call light may hold up to three NA sub stations. Use NR-4AS13 for more than three NA sub application. (4) Remove the D - E link on each NA sub station. N : PS-2420S, PS-2420UL 100 Nurse Call Lineup Call extension m P.104 NEM-60A 60-call master Unit dimensions NEM-60A 60-call master 60-call master NB-U NEM-70 NEM-70A 70-call master 70-call master Music adaptor m P.102 NEM-80 NEM-80A 80-call master 80-call master NEM-90 NEM-90A 90-call master 90-call master NEM-100 NEM-100A 100-call master 100-call master NEM-110 NEM-110A 110-call master 110-call master NEM-120 NEM-120A 120-call master 120-call master NEM-40A/C 260 746 896 1046 1196 15 47.5 NA-NE 142 340 74 83.5 82 Specifications (NEM) Power source 70 NAR-6A NAR-2A 55 Power supply Communication 83.5 120 115 83.5 NBY-1A 70 43 NE-JA 23 3 10 (2-gang) 94 Output Wiring Distance 232 83.5 NA-T/A 115 95 *NEM-n/7.A width : Reduce 100mm (handset part) for each sized station. 120 185 220 NBY-4A 68 211 180 169 83.5 NA-A/AN 160 176 140 NEM-50A ~ NEM-120A 446 596 NB-L 101 50-call master NEM-60 260 140 346 496 116 NEM-50A 50-call master Unit dimensions NEM-40/C 70 NEM-50 176 140 260 COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM IER-2 105 24V DC, 45W max. 2.5W standby (40-call) 24V DC, 180W max. 7.5W standby (120-call) PS-2420S, PS-2420UL (40-call) Open voice press-to-talk or handset voice actuated. Sub calls in w/tone & LED latching at master. Press TALK button to transmit, release to listen, or lift handset. At sub, pretone and voice when selected. Talk hands-free. Press ALL CALL button to activate all sub stations. 500mW max., adjustable. All Call: 6W, 12W. 24W (120-call) Selectively up to 10 subs w/TALK: 3W 2 wires per sub, non-twisted (1 common + no. Subs) NEM to NA subs 130m(0.65mma) 200m(0.8mma) Call switching device Features Call switching device NBJ-40* Call switching device NBJ-20B* Call switching device Used for NBJ-40B* NBJ-20 for NEM-10/C & NEM-20/C NBJ-40 for NEM-30/C & NEM-40/C NBJ-20B for NEM-10A/C & NEM-20A/C NBJ-40B for NEM-30A/C & NEM-40A/C Call switching device *Not available in Europe NEM-20/C NEM-20/C 1 2 3 4 ... n E 1 2 3 4 ... n E 1 2 3 4 ... n E M1 1 2 3 4 ... n E M2 S 1 2 3 4 ... n E M NBJ-20 NBJ-20B NA-A, AN, NE NB-L M1 : Master station 1. M2 : Master station 2. S : Sub station. (*)Terminal M remains unused. (on NBJ-20B) Music adaptor Features l Distributes music to all subs with auto mute while communicating. l When NEM includes NEW-5 adaptor(s), NB-U cannot be used. Wiring NA-A/AN/NE NB-L Used for NEM-n/C, NEM-nA/C (n = 10 ~ 40) NEM-40A/C 1 2 3 4 5 6 7 8 9 10 40 E NB-U B Y B Y A1 V1 A1 V1 A2 V2 A2 V2 A3 V3 A3 V3 A4 V4 A4 V4 E COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM NBJ-20* Wiring l Switches all NA sub wiring from one master to the other to route all call-ins to the master on duty. l NBJ-20 & NBJ-20B are equipped with a rotary switch, and NBJ-40 & NBJ-40B with two rotary switches. l When the rotary switch is put to 1 position, all the sub wiring is connected with Master station(M1). To switch the sub wiring to Master station(M2), put the rotary switch to 2 position. E BGM 8Ω 8Ω NB-U Music adaptor l As shown, connect NB-U to 8 Ohm output of Amplifier with twisted pair wires. l Remove jumpers between A1~V1, A2~V2,A3~V3, A4~V4 on master station. l Amplifier requirements: Input: 100mV for rated output. 10W w/8d output or 10W w/4~16d output. l Do not use 1Kd output on the amplifier. Specifications Power source Permitted input Wiring Distance 6V DC, supplied by NEM. 5W. 10W at its peak. 3 wires commom + 2 per 10-call (max.11). NB-U to NEM 10m(0.65mma) 15m(0.8mma) NB-U to Amp. 75m(0.65mma) 115m(0.8mma) 102 Nurse Call Dual-master call adaptor Features COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM 103 l Common NA subs place a call ringing two NEM masters. l One NEW-5 req’d for every five subs calling both masters. Eight NEW-5 for 40 sub stations, can be powered with one PS-1225S. Used for NEM-n/C, NEM-nA/C (n=10~40) Wiring NA-A/AN/NE NA-A NEM-40A 2xNA 4+1xn A E A E A E A E A E N NEM-40A 4+1xn 2 40 3 4 4 5 + - 5 NEW-5 36 37 38 39 40 E H Y Q MA1 MA2 MA3 MA4 MA5 MAE MAH MAY MAQ T : PS-1225S, PS-1225UL 36 37 38 39 40 E H Y Q MB1 MB2 MB3 MB4 MB5 MBE MBH MBY MBQ 1S 1E 2S 2E 3S 3E 4S 4E + 5S - 5E A E A E A E A E A E NA-A A E A E A E A E A E 1 2 3 NA-A/AN/NE 2xNA 36 1 T NEW-5 Dual master call adaptor NEW-5 + - N NA-A N : PS-2420S, PS-2420UL Specifications (NEW-5) Power source Power supply Capacity Communication Wiring Distance 12V DC PS-1225S, PS-1225UL 5 subs per NEW-5. Max. 8 adaptors for NEM-40(A)/C. Separate channel for ea. master. 2 wires, NEW-5 to sub. NEW-5 to sub 130m(0.65mma) 200m(0.8mma) NEW-5 to NEM 100m(0.65mma) 150m(0.8mma) Accessories Call extension Features Wiring l Announces (chime) call tone only, adjustable l Indoor mounting KC-1MRD IER-2 Used for 2 IE series, MK-1GD, MK-2MCD KC-1MRD, KC-1GRD, KB-3MRD NEM-n, NEM-nA, TC-M JB-2MD, JB-2MED, JA-2MECD, JA-2MCD JF-1MD, JF-2MED NP S S Unit dimensions 1 E IER-2 83.5 120 Call extension 29 88 Door release Features Wiring l Door release activation, momentary or talk linecontrolled KC-1MRD Used for Electric door strike (locally available) RY-PA Electric door strike Electric door strike L+ L– YL VC-M – L L+ L– BK RY-PA H LEF-10C H BK : Black(2) YL : Yellow(2) Specifications (RY-PA) Power source Relay contact rating 12V DC. 110V AC, 1A. 24V DC, 1A. ACCESSORIES Door release relay Single-family unit DA-1DS/G, C-123L/A IE-1AD(U), IE-1GD(U) IE-2AD(U), IE-8MD(2) TD-H/B (via DE-UR) LEM-1DL LEF, LEF-C (via RY-PA) MYW-P3CB(3) MYW-P3L(3) (via RY-PA) MK series JA-2MECD, JA-2MCD JB-2MD, JB-2MED JF-1MD, JF-2MED KC-1MRD, KC-1GRD KB-3MRD Multi-family unit DA-2DS/G, DA-4DS/G GF (5) VC-M (via RY-PA) Relay Features Wiring Intercom station can be signaled by external device via RY-AC/A relay. External device will be activated momentarily as long as the call signal on the intercom is activated. Used for TD-H/B, TD-Z/A IE-Series IE-8MD, LEF LEF-10 LE-D (1) (2) PWR 1 E 1 E – + – T WH YL RD RY-A C/A BK YL RY-AC/A (1) External signaling device, bell, etc. (2) Call receive termimal WH : White RD : Red(+) BK : Black(-) YL : Yellow PWR : Power source External signaling relay Specifications (RY-AC/A) Unit dimensions 62 Power source 104 41 Contact rating 12V DC, supplied by power supply of system or trunk line. 0.3A, 240V AC. 1.0A, 24V DC. Bell, buzzer, etc. must be AC operated or DC mechanical type only. 104 Accessories Relay Features Wiring Allows integration of a doorbell, etc. to intercom. The device will be activated as long as handset is ringing. When the intercom is picked up, the device will no longer be activated. MK-DH (1) NP A1 A2 Used for IE chime tone IE-8MD MK-1GD MK-2MCD KC, KB series AT-406 TB-SE(TC-M) TAR-3 MK-1GD PWR A1 A2 WH BL BK S S A + – U TAR-3 (–) (+) OG OG RD W (1) Bell, etc. PWR : Power source WH : White BL : Blue BK : Black(-) RD : Red(+) OG : Orange W : PS-0602D, PS-0602C Unit dimensions 62 External signaling relay Specifications (TAR-3) 41 104 Power source Contact rating 6V DC, supplied by PS-0602D, PS-0602C 0.3A, 240V AC. 1.0A, 24V DC. Doorbell or buzzer must be AC operated or DC mechanical type only. Auxiliary light power control Features Wiring ACCESSORIES MAW-B relay is used for turning on an auxiliary light to spotlight a caller at the entrance. The light is illuminated when the residential call button is pressed, and during visual monitoring mode. KB-3MRD (1) (2) MAW-B WH bn E BL Used for RD KB-3MRD, GF-BC(GF) OG PWR BK N + – bn = b1~b3 Unit dimensions (1) Porch light, etc. (2) Local switch WH : White BL : Blue RD : Red(+) BK : Black(-) OG : Orange(2) MAW-B Auxiliary light control relay 62 Specifications (MAW-B) 104 105 41 Power source Power supply Power consumption Relay contact rating 24V DC. PS-2420S, PS-2420UL of system. 2.5W max. 0.5W standby. Dry closure contact for incandescent light for general lighting of less than 100W. Power Supplies 15V AC Unit dimensions PT-1211D 58 Specifications (PT-1211D) 46 Input voltage & Capacity 230V AC, 50/60Hz Output voltage 15V AC 83 *Manufactured by Sino-American PT-1211D Specifications (PT-1211C) 48 77 PT-1211C 60 Input voltage & Capacity 120V AC, 50/60Hz Output voltage 15V AC *Manufactured by Sino-American Used for PT-1211C DA-1MD 6V DC Unit dimensions Specifications (PS-0602C) Input voltage & Capacity 120V AC, 50/60Hz Output voltage 6V DC, 0.2A 75 PS-0602D, PS-0602C Specifications (PS-0602D) 39.5 PS-0602D PS-0602C 51 Used for Input voltage & Capacity 230V AC, 50/60Hz. Output voltage 6V DC, 0.2A *Manufactured by Sino-American C-123L/A, AT-406, LEM, TAR-3 12V DC 167 PS-1225S, PS-1225UL 52 90 PS-1225S PS-1225UL PS-1225 (without AC cord) Specifications (PS-1225S, PS-1225UL, PS-1225) Input voltage & Capacity 100-240V AC, 50/60Hz 37W/6582VA Output voltage 12V DC, 2.5A POWER SUPPLIES Unit dimensions Used for IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-2A2D(U), IE-8MD, LEM-1DL, LEF, LEF-C, TD-H/B, TD-Z/A, VC-M, MP-S, NEW-5 (NEM), TB-AD10 (TC-M) 106 Power Supplies 18V DC Unit dimensions Used for PS-1820S 52 90 IE-8MD, JB-2MED, JB-2MD, JBW-BA, JF-1MD, JF-2MED MK-1GD, MK-2MCD, MY-CU, MYW-P1L(LEF), MYW-P3L(LEF) TC-M, MYW-BA, KC-32EU, RY-3DL 167 Specifications (PS-1820S, PS-1820UL, PS-1820) Input voltage & Capacity 100V-240V AC, 50/60Hz, 45W/75-95VA Output voltage 18V DC, 2A PS-1820S PS-1820UL PS-1820 (without AC cord) 24V DC Unit dimensions Used for JA-2MECD, JA-2MCD, GF-BC, GF-VBC/A, GFW-VBC, MAW-B MYW-BA, YAZ-90-3W, NEM-(A)/C, KC-1MRD, KC-1GRD KB-3MRD, KC-32EU, RY-3DL, MU-100 PS-2410LD 164 Specifications (PS-2410LD) 220-240V AC, 50/60Hz 35W Output voltage 24V DC, 1A 66 95 RD BK (+) (–) Specifications (PS-2410LC) Input voltage & Capacity 120V AC, 50/60Hz 35W Output voltage 24V DC, 1A PS-2420S, PS-2420UL 52 90 Specifications (PS-2420S, PS-2420UL, PS-2420) 167 POWER SUPPLIES PS-2410LD PS-2410LC PS-2420S PS-2420UL PS-2420 (without AC cord) 107 Input voltage & Capacity RD : Red (+). BK : Black (-). Input voltage & Capacity 100-240V AC, 50/60Hz 60W/100-125VA Output voltage 24V DC, 2A Communication Distance The below graph is to assist you in determining the diameter of wires or communication distance required. Example; To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires; 1. On the graph; Draw a line from IE-1AD(U) on point A 7.8, crossing the line B at the point 0.8 to reach a point reading 225. A Distance B IE-1AD(U) 0.8 28 225 (m) COMMUNICATION DISTANCE CALCULATION GRAPH SYSTEM & MODELS TB-AD1, AD10 [TC-M] C-123L/A IE-1GD(U) [IEH-1CD] IE-2AD(U) [IEH-1CD] IE-2A2D(U) [IEH-1C2D] A COMMUNICATION DISTANCE ...m FIXED NUMBER FOR DISTANCE BY ITEM 2,000 MP-1S, MP-3S 3.4 NEM-nA/C, NEM-n/C 3.9 5.2 TCS-MH IE-1AD(U) [IF-DA] IE-1GD(U) [IF-DA] IE-2AD(U) [IF-DA], IE-2A2D(U) DE-UR [IF-DA] AP-1M/A, AP-5M/A, AP-10M/A 6.8 7.8 10.4 B DIAMETER mm 1.6 900 800 1.4 700 1.2 600 1.0 500 0.8 400 17.4 0.65 20.9 26.2 300 0.5 225 200 VC-nM, VCH [VC-K] 34.0 36.7 AT-206 [AT-306x3] TC-M [TB-SE] 100 MC-60/4A 90 TD-1H, TD-3H, TD-6H TD-12H, TD-24H TD-6Z, TD-12Z 80 AT-406 50 70 60 COMMUNICATION DISTANCE LEM-1, LEM-3 LEF-3, LEF-5 , LEF-10 LEF-10S LEF-3C, LEF-5C, LEF-10C 1,000 40 30 20 NOTES; IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station. Video Intercoms are not included in the graph. 108 97 INDEX PAGE A AI-900AF ............................................ 82 AI-900AL ............................................82 AI-900CO............................................82 AI-900DI ............................................82 AI-900MF............................................82 AI-900MS ...........................................82 AI-900RS............................................82 AI-900TI .............................................82 AI-910DI ............................................82 AI-MS900 ........................................... 81 AI-PN100B ......................................... 82 AI-PU200............................................ 82 AI-RS150............................................81 AI-RS160 ........................................... 81 AI-RS170 ........................................... 81 AI-RS180 ........................................... 81 AI-YC303 ............................................ 82 AP-10M ..............................................92 AP-1M ................................................92 AP-5M ................................................ 92 AS-3A ................................................. 91 AS-3N................................................. 91 AT-206 ................................................ 70 AT-306 ................................................ 70 AT-406 ................................................ 70 AT-406B/A .......................................... 70 AT-406P..............................................70 AX-084C .............................................78 AX-16SW............................................ 77 AX-248C ............................................. 78 AX-320C ............................................. 78 AX-8M ................................................ 77 AX-8MV .............................................. 77 AX-DM .......................................... 34,77 AX-DV................................................. 77 AX-DVF............................................... 77 AX-DVF-P............................................ 77 AX-DV-P ............................................. 77 PAGE B BG-10C............................................... 69 PAGE C C-123L/A ............................................ 28 C-D ..................................................... 28 C-ML/A................................................ 28 INDEX D PAGE DA-1AG .............................................. 27 DA-1AS .............................................. 27 DA-1DG .............................................. 27 DA-1DS .............................................. 27 DA-1MD ........................................ 27,60 DA-2DG .............................................. 60 DA-2DS ............................................. 60 DA-4DG .............................................. ......................................... 60 DA-4DS .............................................. 60 DAR-1 ........................................... 27,60 DAW-P........................................... 27,60 DE-UR ................................................ 71 PAGE G GF-10K .............................................. 55 GF-10KP.........................................40,55 GF-1D ................................................ 57 GF-1DK .............................................. 57 GF-1MD ............................................. 57 GF-1MDK ........................................... 57 GF-1P ............................................ 39,55 109 GF-2B ............................................39,56 GF-2F ............................................ 39,56 GF-2P ............................................39,55 GF-3B ............................................39,56 GF-3F ............................................39,56 GF-3P ............................................39,55 GF-4P ............................................39,55 GF-4Z ................................................ 58 GF-AD ................................................ 55 GF-AP ............................................39,55 GF-BC ................................................. 58 GF-BP ............................................ 39,55 GF-DA ................................................. 55 GF-DP .................................................55 GF-GD-TS ........................................... 53 GF-GMK ............................................. 53 GF-GTX .............................................. 54 GF-MK ................................................ 57 GF-nH (n=102, 202, 103, 203, 303) .......39,56 GF-nHB (n=102, 202, 103, 203, 303)..... 39,56 GF-NS ................................................. 55 GF-NSP.......................................... 40,55 GF-SW ................................................55 GF-VA .................................................55 GF-VBC ...............................................58 GF-VP ............................................ 39,55 GFW-LD.............................................. 59 GFW-S ............................................43,57 GFW-VBC ........................................... 59 GH-10K .............................................. 40 GH-1AD .............................................. 42 GH-1KD .............................................. 42 GH-1KDS ............................................ 40 GH-1MD ............................................. 42 GH-4Z ................................................ 43 GH-AD ................................................ 39 GH-BC ................................................ 43 GH-BCX .............................................. 44 GH-CCTV............................................. 46 GH-DA ............................................... 39 GH-DP ................................................ 39 GH-HS ................................................ 42 GH-MK ............................................... 43 GH-NS ................................................ 40 GH-RY ................................................ 44 GH-SW................................................. 39 GH-VA ................................................ 39 GH-VBC .............................................. 43 GH-VBX .............................................. 44 GHW-LC ............................................. 45 PAGE I IAI-100 .............................................. 84 IAX-100 .............................................. 84 IE-1AD(U)........................................... 30 IE-1GD(U)........................................... 31 IE-2A2D(U)......................................... 32 IE-2AD(U)........................................... 32 IE-8HD................................................ 33 IE-8MD ............................................... 33 IE-DC .................................................. 34 IE-DL1 ................................................ 34 IE-DL2 ................................................ 34 IE-DL3 ................................................ 34 IE-FY................................................... 34 IEH-1C2D ........................................... 32 IEH-1CD ............................................. 31 IE-JA .................................................. 34 IER-2.................................................104 IF-DA .................................................. 34 IME-100 .............................................83 IME-150 .............................................84 IMU-100 ............................................. 83 ISE-100 ..............................................84 PAGE J JA-2HCD .............................................10 JA-2MCD ............................................ 9 JA-2MECD ............................................ 9 JA-2SD ............................................8,10 JA-D .................................................. 7,9 JA-DAC ................................................9 JA-DGC ...............................................9 JB-2HD .................................................8 JB-2MD ................................................7 JB-2MED ..............................................7 JB-DA ..................................................7 JB-DV ................................................... 7 JB-DVF ................................................. 7 JBS-2AD ...............................................8 JBS-2ADV.............................................8 JBS-2ADVF ...........................................8 JBS-2AED .............................................8 JBS-2AEDV...........................................8 JBS-2AEDVF......................................... 8 JBW-BA ...............................................18 JBW-D .................................................. 8 JDW-C .................................................. 9 JF-1MD .................................................3 JF-1FD ................................................. 4 JF-1SD.................................................. 4 JF-DA ................................................... 3 JF-DV ................................................... 3 JF-DVF.................................................. 3 JFS-1AD .............................................. 4 JFS-1ADV ............................................ 4 JFS-1ADF ............................................. 4 JF-2MED............................................... 5 JF-2HD ................................................. 6 JF-2SD ................................................. 6 JFS-2AED ............................................. 6 JFS-2AEDV ........................................... 6 JFS-2AEDF............................................ 6 K PAGE KA-DGR PANEL ..................................12 KAW-D ................................................18 KB-3HRD .............................................16 KB-3MRD.............................................15 KB-3SD ...............................................16 KB-DAR ..............................................15 KC-1GRD.............................................13 KC-1HRD.............................................14 KC-1MRD ............................................11 KC-1SD ...............................................14 KC-32EU ........................................17,25 KC-DAR .........................................11,13 KCS-1ARD ..........................................12 L PAGE LE-A ..................................................69 LE-A3 .................................................69 LE-AN .................................................69 LE-AN3................................................69 LE-B ...................................................69 LE-BN ................................................. 69 LE-C ...................................................69 LE-CN .................................................69 LE-D ...................................................69 LE-DA .................................................69 LE-DL ..........................................69 LEF-10 .........................................65 LEF-10C ..................................24,67 LEF-10S .......................................66 LEF-10W ......................................65 LEF-1C .........................................69 LEF-20(S) ....................................66 LEF-3 ...........................................65 LEF-30(S) ....................................66 LEF-3C ....................................24,67 LEF-40(S) ....................................66 LEF-5 ...........................................65 LEF-5C ....................................24,67 LEF-5W ........................................65 LEM-1 ......................................... 64 LEM-1DL .....................................63 LEM-3 .........................................64 LEW-10 .......................................66 LEW-10S ..................................... 66 LEW-5 ......................................... 66 M PAGE MAW-B.......................................105 MC-60/4A ....................................90 MC-60/4B ....................................90 MC-A/A ........................................90 MCW-S ........................................18 MK-1GD .......................................19 MK-1HD.......................................20 MK-2DA ......................................25 MK-2DG ......................................25 MK-2DG PANEL ..........................25 MK-2HCD ....................................22 MK-2MCD ...................................21 MK-2SD .......................................20 MK-D ...........................................22 MK-DAC ......................................21 MK-DBC ...................................... 21 MK-DGC ......................................21 MK-DH ....................................19,21 MK-DV ........................................19 MK-DVF ......................................19 MKS-1GD ...................................20 MKS-1GDV ..................................20 MKS-1GDVF ................................20 MKW-P ........................................20 MKW-R .......................................22 MP-1S .........................................91 MP-3S .........................................91 MY-CU ........................................23 MYH-CU .....................................23 MYH-CUB ....................................24 MYW-BA .....................................26 MYW-P1L .............................. 24,68 MYW-P3L .............................. 24,68 PAGE NA-A ...................................... 85,99 NA-AN .................................... 85,99 NA-NE .................................. 85,100 NAR-2A .....................................100 NAR-3 ........................................100 NAR-6A .................................. 86,99 NA-T/A ................................. 86,100 NBJ-20 ......................................102 NBJ-20B ....................................102 NBJ-40 ......................................102 NBJ-40B ....................................102 NB-L .....................................85,100 NBR-7AS .............................86,100 P PAGE PD-1 .................................................. 72 PD-2 .................................................. 72 PS-0602C .........................................106 PS-0602D .........................................106 PS-1225 ...........................................106 PS-1225S .........................................106 PS-1225UL .......................................106 PS-1820 ............................................107 PS-1820S .........................................107 PS-1820UL .......................................107 PS-2410LC .......................................107 PS-2410LD .......................................107 PS-2420 ...........................................107 PS-2420S .........................................107 PS-2420UL .......................................107 PT-1211C .........................................106 PT-1211D .........................................106 R PAGE RY-3DL ..........................................18,26 RY-AC/A ............................................104 RY-PA ...............................................104 T PAGE TAR-3 ................................................105 TB-AD1 ...............................................88 TB-AD10 .............................................88 TB-ADD...............................................88 TB-ADM10 .........................................89 TB-SE .................................................87 TC-10M ..............................................87 TC-10MD............................................ 88 TC-20G............................................... 87 TC-20M ..............................................87 TC-40G ............................................... 87 TC-40GS ............................................ 87 TC-DC ................................................ 29 TC-MH ............................................... 29 TCS-MH ............................................. 29 TD-12H/B ........................................... 72 TD-12Z/A ........................................... 72 TD-1H/B ............................................. 71 TD-24H/B ...........................................72 TD-3H/B ............................................. 71 TD-6H/B ............................................. 71 TD-6Z/A ............................................. 72 TDW-1/A ............................................ 72 TDW-12/A .......................................... 72 TDW-24/A .......................................... 72 TDW-3/A ............................................ 72 TDW-6/A ............................................ 72 V PAGE VC-0M ............................................... 61 VC-10M .............................................. 61 VC-1M ................................................ 61 VC-26MT ............................................ 62 VC-26MY............................................ 62 VC-2M ................................................ 61 VC-42MY............................................ 62 VC-4M................................................ 61 VC-58MT............................................ 62 VC-6M................................................ 61 VC-8M................................................ 61 VC-BBX .............................................. 62 VCH-16 .............................................. 61 VCH-8 ................................................ 61 VC-K .................................................. 61 VGX-D-YBOX 51 W PAGE W-DIN11 ............................................ 57 Y PAGE YAZ-90-3W......................................... 74 INDEX N NBR-7AS-S ......................................100 NBR-8A ............................................100 NB-U.................................................102 NBY-1A ............................................100 NBY-4A ............................................100 NBZ-M ............................................... 91 N-EA .................................................. 91 NE-JA .........................................86,100 NEM-10/C ..................................... 85,99 NEM-100 ....................................... 86,99 NEM-100A .................................... 86,99 NEM-10A/C ................................... 85,99 NEM-110 ....................................... 86,99 NEM-110A..................................... 86,99 NEM-120 ....................................... 86,99 NEM-120A..................................... 86,99 NEM-20/C .....................................85,99 NEM-20A/C ...................................85,99 NEM-30/C .....................................85,99 NEM-30A/C ...................................85,99 NEM-40/C .....................................85,99 NEM-40A/C ...................................85,99 NEM-50 .........................................86,99 NEM-50A ......................................86,99 NEM-60 .........................................86,99 NEM-60A........................................86,99 NEM-70 ........................................86,99 NEM-70A .......................................86,99 NEM-80 ......................................... 86,99 NEM-80A ...................................... 86,99 ............................................ 86,99 NEM-90 NEM-90A ...................................... 86,99 NEW-5 ..............................................103 NH-1SA/A .......................................... 96 NH-2SA/A ......................................... 96 NHR-30K ........................................... 95 NHR-3A-4 .......................................... 96 NHR-3TS ........................................... 96 NHR-4A/A ......................................... 96 NHR-7A ............................................. 96 NHR-8A ............................................ 96 NHR-DP.............................................. 96 NHR-SP.............................................. 95 NHX-30G ........................................... 95 NHX-50M ........................................... 95 NHX-80X ........................................... 95 NP-B .................................................. 91 NP-W ................................................. 91 NR-4AS13 ........................................100 110