Will Not Run
Gas
Manual Timer (Sheet 2 of 2)
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
YES
NO
Does the Fan Motor
Run?
NO
Replace the Fan
Motor.
YES
Note: Only for non time
delay machines
Replace Motor
Control Relay.
Is there voltage across
terminals "3" & "5" of
the fan motor
centrifugal switch with
the fan motor running?
YES
Replace Fan
Motor.
NO
Is there voltage at
terminal "5" on the
motor control relay to
to supply neutral?
NO
Correct wiring
between terminal "5"
and supply voltage.
Is there voltage to
terminal "6" on the
motor control relay and
supply neutral?
NO
Correct wiring
between terminal
"6" and power
supply.
YES
YES
Is there voltage across
terminal "5" & "8" of the
motor control relay?
YES
Replace motor
control relay.
Is there voltage across
terminal "6" & "9" of the
motor control relay?
YES
Replace motor
control relay.
NO
NO
Is there voltage across
terminals "1" & "4" of
Fan Motor?
NO
Correct wiring
between Fan
Motor and contact
"8" on the Motor
Control Relay.
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
NO
Correct wiring
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
YES
YES
Does the Cylinder
Motor Run?
NO
Replace the
Cylinder Motor.
YES
**
Tested with the start switch pressed in.
The Cylinder and
Fan Motors are
operational.
T043D
T043D
38
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201