Overview of alarms
06/2007
NCK alarms/ISO alarms
Program Continuation:
14050
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 nesting depth for arithmetic operations exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For calculating arithmetic expressions in NC blocks, an operand stack with a fixed set size is used.
With very complex expressions, this stack can overflow.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Divide up complex arithmetic expressions into several simpler arithmetic blocks.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
14051
Channel %1 block %2 arithmetic error in part program
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In calculating an arithmetic expression, an overflow has occurred (e.g. division by zero)
In a data type, the representable value range has been exceeded
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Analyze the program and correct the defective point in the program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
14055
Channel %1 block %2 impermissible NC language substitution, error
code %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
Definitions:
This alarm occurs in conjunction with an NC language substitution configured in
$MA_AXIS_LANG_SUB_MASK. Error code %3 gives more detailed information about the cause of
the problem:
Error code:
1: Several events had been programmed, causing the replacement cycle to be called. Only one substitution is allowed per part program line.
2: A non-modal synchronized action had also been programmed for the part program line with the NC
language substitution.
3: The system variables $P_SUB_SPOSIT and $P_SUB_SPOSMODE were called outside a replacement cycle.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify the NC program
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
14060
Channel %1 block %2 invalid skip level with differential block skip
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A skip level larger than 1 is specified for "differential block skips" (in package 1, the specification of a
value for the skip level will already be rejected by the compiler as syntax error, namely, only one "suppress block" level ON/OFF is possible).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Enter skip level (the number behind the slash) 1.
2-122
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition