Download Radyne MM200 Technical information

Transcript
MM200 High-Speed Microwave Modem
Appendix A
bytes to index into the
selected channel
status area. The
nonvolatile data might
grow with future
firmware revisions.
Refer to discussion
on forward/backward
compatibility.
<4>
Data Rate
7000000 - 200000000
<4>
Symbol Rate
3500000 - 28000000
<4>
IF Frequency
50000000 - 90000000
<4>
Transmit Power
-200 to 0
<1>
Carrier Control
0 = off, 1 = on
<1>
IF Separation
100 - 150%
<1>
Modulation
0 = qam4
1 = qam16
2 = qam32
3 = qam64
4 = qam128
5 = qam256
<1>
Spectrum
0 = normal, 1 = inverted
<1>
Carrier Mode
0 = Normal
1 = CW
2 = Offset 1Hz
3 = 100KHz
4 = 3.5MHz
5 = Sweep Up
6 = Sweep Down
<1>
Channel Setting
0 = auto
1 = one
2 = two
3 = three
4 = four
5 = debug
<1>
Major Alarm 1 Mask
0 = Mask, 1 = Allow
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bit 2 – 7 = Spare
<1>
Major Alarm2 Mask
0 = Mask, 1 = Allow
Bit 0 – 7 = Spare
<1>
Minor Alarm1 Mask
0 = Mask, 1 = Allow
Bit 0 = Tx clock activity detect
Bit 1 = Tx data activity detect
Bit 2 = Frame Lock
TM086 – Rev. 4.1
A-13