Download ALLEN & HEATH iDR-4 User guide

Transcript
iDR-in/out EXPANDER
AP4774
User Guide
lock
link
power
iDR-in
AUDIO INPUT EXPANDER
lock
link
power
iDR-out
AUDIO OUTPUT EXPANDER
100 - 240V~
47-63Hz ~ 25W MAX
next
previous
OUT DR-LINK
IN
EXPANDER INPUTS
IN 8
IN 7
IN 6
IN 5
IN 4
IN 3
IN 2
IN 1
OUT 4
OUT 3
OUT 2
OUT 1
AUDIO OUT
FUSE: T500mAL
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
SERIAL NUMBER
DIGITAL EXPANDER
Made in the UK by ALLEN&HEATH LIMITED
100 - 240V~
47-63Hz ~ 25W MAX
next
previous
OUT DR-LINK
IN
MIC/LINE INPUTS
Complies with UL6500, CSA-E65, EN60065
EXPANDER OUTPUTS
OUT 8
OUT 7
OUT 6
OUT 5
AUDIO IN
FUSE: T500mAL
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
SERIAL NUMBER
DIGITAL EXPANDER
Made in the UK by ALLEN&HEATH LIMITED
Complies with UL6500, CSA-E65, EN60065
LINE OUTPUTS
iDR-in and iDR-out are add-on audio expander units for the Allen & Heath iDR-4 and iDR-8 audio mix processors.
They provide additional analogue audio inputs and outputs to add to those on the main unit. The iDR-in has 8 mic/line
inputs, the iDR-out has 8 line outputs. One or both may be connected to the iDR. Only one of each may be added to
the iDR system bringing it up to a maximum 16x16 audio matrix. These units do not have any processing built in. They
simply convert between analogue and digital audio to work with an 8 channel wide digital bus which feeds the main
unit via a CAT5 STP cable. The iDR-in features high grade mic/line preamps with PC configured gain, pad and
phantom power switching, and a built-in soft clip limiter. The iDR-out provides electronically balanced differential
outputs. The processing is available on the main iDR-4 or iDR-8 unit which features the full 16x16 DSP matrix. Both
units have 8 front panel LEDs in addition to the 3 status indicators. These are 3-colour soft LEDs which can be
assigned as audio meters, mute indicators or patch related indicators. They are programmed in the usual way using
the iDR System Manager software. Control of the expanders is via the DR-Link port using a CAT5 STP cable. This
means that two CAT5 cables are required to interconnect an expander to the main unit. Maximum distance between
the units is 250 metres. Local mains power is required.
This product complies with the European Electromagnetic
Compatibility directives 89/336/EEC & 92/31/EEC and the
European Low Voltage Directives 73/23/EEC & 93/68/EEC.
NOTE: Do not remove the cover of the unit. There are no user serviceable
parts inside. Any changes or modifications to the equipment not approved by
Allen & Heath could void the compliance of the equipment and therefore the
users authority to operate it.
iDR-in/out User Guide AP4774 Issue 2
Copyright © 2003 Allen & Heath Limited. All rights reserved
Whilst we believe the information in this guide to be reliable we do not assume
responsibility for inaccuracies. We also reserve the right to make changes in
the interest of further product development.
iDR-in/out User Guide AP4774
1
The iDR-in and iDR-out expanders can be rack mounted or free standing. There are no
user controls on the front panel, only the status and assignable LEDs. Allow a minimum of
75mm clearance behind the unit for the connectors and cables. Ensure adequate
ventilation to the side of and behind the unit.
It is shipped with its rack ears fitted and its feet removed ready to be mounted in a standard
19” equipment rack. 1U rack space is required. For desk mount operation remove the two
rack ears using a Torx (star head) T10 screwdriver. Fit the four plastic feet provided by
pressing them into the underside.
44mm
48mm 1.7"
1.9" 1U
iDR-in and iDR-out EXPANDERS
443mm
17.4"
lock
link
483mm
19"
power
iDR-in
AUDIO INPUT EXPANDER
lock
link
power
iDR-out
AUDIO OUTPUT EXPANDER
307mm
12"
Remove 2x rack ears
M3 Torx T10
Fit 4x feet
100 - 240V~
47-63Hz ~ 25W MAX
FUSE: T500mAL
232mm
9.1"
75mm
3"
Make sure you have read the Important Safety
Instructions printed earlier. Also check that your local
mains supply is compatible with that printed on the rear
panel of the unit. Ensure that the correct mains lead with
moulded plug and IEC connector has been supplied. For
your own safety and optimum performance make sure the
system is correctly grounded.
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
To avoid any unexpected audible clicks or thumps
always turn connected power amplifiers down or off before
switching the iDR or any other signal equipment on or off.
Turning the expander on or off
lock
link
power
First make sure
the unit is correctly plugged up and connected to the iDR-4(8).
This is described below. Turn the unit on by pressing the rear
panel power ON/OFF switch. The power LED lights up. The
link LED lights if the DR-Link connection is established with the
iDR-4(8). The lock LED lights once the link is established and
audio is correctly communicated with the iDR-4(8). The iDR
System Manager detects the presence of the expander.
If one or more of the LEDs do not light then check that the
cables are correctly fitted and the iDR-4(8) is functioning
normally.
*8 Diagnostics
Audio Exp:In/Out
2
Checking for expanders You can use the front
panel iDR-4(8) Setup menus to check if any expanders are
connected and recognised. This is useful when the expanders
are located far away from the main unit. With the face plate
removed access menu *8 Diagnostics and scroll to Audio Exp.
Refer to the iDR-4 user guide AP5230 or iDR-8 user guide
AP4530 for further details.
IDR-in/out User Guide AP4774
CONNECTING THE INPUT EXPANDER
IN
8
7
6
5
4
3
2
1
OUT 8
7
6
5
4
3
2
1
IN 16
15
14
13
12
11
10
9
IN
8
7
6
5
4
3
2
1
OUT 8
7
6
5
4
3
2
1
OUT 16
15
14
13
12
11
10
9
Connecting to the iDR-4(8) You can connect
either or both expanders according to the requirements of your
application. The iDR-in AUDIO OUT connects to the iDR-4(8)
AUDIO IN. The iDR-out AUDIO IN connects to the iDR-4(8)
AUDIO OUT. Ensure that the expander DR-Link IN connects to
DR-Link on the iDR-4(8) it is associated with.
If both
expanders are used with the same iDR-4(8) then daisy chain
from DR-Link OUT on one to DR-Link IN on the other. DR-Link
can also be daisy chained from or to iDR-switch units if you
are using them as well.
IN OUT
AUDIO
DR-LINK
iDR
iDR-in
OUT
CONNECTING THE OUTPUT EXPANDER
IN OUT
AUDIO
DR-LINK
iDR
next
previous
OUT DR-LINK
IN
AUDIO OUT
iDR-out
DIGITAL EXPANDER
IN
CONNECTING BOTH EXPANDERS
IN
8
7
6
5
4
3
2
1
OUT 8
7
6
5
4
3
2
1
IN 16
15
14
13
12
11
10
9
Fully expanded iDR-4(8) The diagram below shows
the iDR-8 with both the input and output expanders fitted.
Note the connection of DR-Link which is daisy chained from
one unit to the next. If an iDR-switch unit is also fitted then
daisy chain DR-Link from the last expander to the switch box.
Make sure you plug into the correct DR-Link socket.
IN OUT
AUDIO
DR-LINK
iDR
iDR-in
Use CAT5 STP cable. A pair of standard 2 metre cables is
provided with each expander. Maximum cable length is 250
metres. This means that the expander units can be used for
remote audio over CAT5 cable.
AUDIO
DR-LINK
OUT
OUT 16
15
14
13
12
11
10
9
iDR-out
IN
INPUT
iDR-in
250 metre max
AUDIO OUT
AUDIO IN
CAT5
DR-Link OUT IN
iDR-8
OUTPUT
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
iDR-out
250 metre max
AUDIO OUT
AUDIO IN
CAT5
SIG GEN
DR-Link OUT IN
ACTIVE MONITOR
DR-Link
CAT5
CAT5
iDR-in/out User Guide AP4774
3
AUDIO
DR-LINK
iDR-in
iDR Unit B
15A
14A
13A
12A
11A
10A
9A
DR-LINK
Expanded multiple iDR system
IN 8A
7A
6A
5A
4A
3A
2A
1A
OUT 8
7
6
5
4
3
2
1
IN 8B
7B
6B
5B
4B
3B
2B
1B
OUT 8
7
6
5
4
3
2
1
OUT 16B
15B
14B
13B
12B
11B
10B
9B
IN OUT
DR-LINK
iDR Unit A
IN 16A
OUT
OUT IN
DR-LINK
IN OUT
iDR-out
This diagram
shows an iDR system with two iDR-8 units and both expanders
fitted. A system could also be created with iDR-4 units or a mix
of iDR4 and iDR-8 units. DR-Link is only required to connect to
the expanders, not between the main units. Make sure you
connect DR-Link to the iDR associated with each expander.
Make sure you plug into the correct DR-Link socket. In this
case do not daisy chain DR-Link from one expander to the
other.
Use CAT5 STP cable. Maximum cable length is 250 metres.
Maximum audio matrix is 16x16. The audio link cable carries 8
channels. This can provide a distributed system with 8
common channels and 8 local channels at each unit.
IN
Mic/Line Inputs x8
Performance
Female 3pin XLR
Frequency response 20Hz-20kHz +0/-0.5dB
Electronically balanced, pin 2 hot
Crosstalk <-80dB @ 1kHz, 0dB gain
Impedance 2k (pad out),>10k ohm (pad in)
THD+noise <0.01% @ 1kHz, 0dBu
Sensitivity -50dBu to +5dBu
Residual output noise <-93dBu
Gain range -15 to +50dB in 3dB steps
Input to output noise @ 0dB gain <-87dBu
Pad -20dB
Input to output noise @ 50dB gain <-73dBu
Sensitivity (pad out) -50 to -5dBu
Latency <2.4ms expander XLR to/from iDR XLR
Sensitivity (pad in) -30 to +15dBu
This is <0.084ms additional to iDR
Maximum input level +33dBu
Pre converter soft limiter -4dBFS, switchable
Status LEDs
Phantom power +48V DC switched
Power –mains power on
+48V
Link – iDR-Link control communicating
Line Outputs x8
Male 3pin XLR
Soft LEDs
Impedance <75 ohms
Assignable by the installer
Maximum output +18dBu
iDR-in 8x front panel
Expander Input / Output Port
3-colour – green, yellow, red, off
RJ45 connector
Function 3-colour signal meters
Proprietary 8 channel digital audio
Mute on/off
Connects to iDR-4 or iDR-8 main unit
Static patch related
Universal mains input switched mode design
IEC 3pin
A/D dynamic range 109dB A-weighted
Country dependent mains lead supplied
DR-Link Port
Serial control of iDR expander units
Proprietary Allen & Heath control protocol
ADC
1
+48V
GAIN
ANALOG
INPUT 8
LIMIT
PAD
+
-
PREAMPS AND
LIMITERS
8
ADC
SOFT LEDs 1-8
DR-LINK
ANALOG
OUTPUT 1
iDR-out
Rear panel power on/off switch
DAC
AC mains input 100-240V AC 50/60Hz
1
AUDIO IN
25VA max
Fuse T500mAL 20mm
8
1U rack
483 x 232 x 44mm
SOFT LEDs 1-8
19” x 9.1” x 1.7”
IN and OUT ports provided to allow daisy
chaining through multiple units
Desk
CAT5 STP cable up to 300 metres (1000 feet)
Weight
ANALOG
OUTPUT 8
DAC
Mechanical
RJ45 connector
4
+
-
Power Supply
24bit resolution
112dB unweighted
LIMIT
PAD
CONTROL
Converters
D/A dynamic range 115dB A-weighted
ANALOG
INPUT 1
AUDIO OUT
iDR-out 8x front panel
106dB unweighted
GAIN
Lock –audio communicating
Electronically balanced, pin 2 hot
CAT5 STP cable up to 250 metres (825 feet)
iDR-in
443 x 232 x 48mm
DR-LINK
CONTROL
17.4” x 9.1” 1.9”
3.5kg, 7.7lbs
IDR-in/out User Guide AP4774