Start-Up Checking Unit Heater Rate Table 6. Type of Gas Natural NOTICE: Overfiring! Never overfire the unit heater, as this could cause unsatisfactory operation, or shorten the life of the heater. Gas appliances are rated based on sea level operation, with no adjustment required at elevations up to 2000 feet (610 m). At elevations above 2000 feet (610 m), input ratings should be reduced by 4 percent for each 1000 feet (305 m) above sea level. Check the input rate as follows: 1. Turn off all other gas appliances that utilize the same gas meter as the unit heater. 100 125 150 175 200 3. Using the gas meter, clock the time that it takes to burn one cubic foot of gas (Heating Value). 225 4. Insert the time, in seconds, into the formula below: 250 Heating Value (Btu/ft3) (3600 s/hr) Time (s/ft3) Example: If the heating value = 1000 BTU/ft3 and the time/ ft3 = 18 s/ft3 then Input Rate = (1000 BTU/ft3) (3600 s/hr) 18 s/ft3 Input Rate = 200,000 BTU/hr (Refer to “General Safety Information,” p. 7 for metric conversions.) 300 350 400 Propane Heating Value 1075 BTU/ft3 (40.1 MJ/m3) 2500 BTU/ft3 (93.1 MJ/m3) ft3/hr 96 40 Orifice Drill 42 54 Input in 1000 Manifold BTU(a) Pressure 2. Let the unit heater run for 15 minutes. Input Rate = Main burner orifice schedule(a) No. of Burner 3.5” wc (0.9 kPA) 10.5” wc (2.6 kPA) Orifices ft3/hr 120 50 Orifice Drill 42 54 ft3/hr 140 60 Orifice Drill 42 54 ft3/hr 163 70 Orifice Drill 42 54 ft3/hr 186 80 Orifice Drill 42 54 ft3/hr 210 90 Orifice Drill 42 54 ft3/hr 233 100 Orifice Drill 42 54 ft3/hr 280 120 Orifice Drill 42 54 ft3/hr 326 140 Orifice Drill 42 54 ft3/hr 372 160 Orifice Drill 42 54 4 5 6 7 8 9 10 12 14 16 Note: When installed in Canada, any references to deration at altitudes in excess of 2000 feet (610 m) are to be ignored. At altitudes of 2000 to 4500 feet (610 to 1372 m), the unit heaters must be orificed to 90 percent of the normal altitude rating, and be so marked in accordance with the CSA certification. (a) This schedule is for units operating at normal altitudes of 2000 feet (610 m) or less. SPECIAL ORIFICES ARE REQUIRED FOR INSTALLATIONS ABOVE 2,000 FEET (610 m). Primary Air Shutter Adjustment After the unit has been operating for at least 15 minutes, adjust the primary air flow to the burners. Turn the frictionlocked, manually-rotated air shutters clockwise to close, or counterclockwise to open (see Figure 20, p. 27 and Figure 2, p. 8). For correct air adjustment, close the air shutter until yellow tips in the flame appear. Then open the air shutter to the point just beyond the position where yellow tipping disappears. Refer to Figure 21. Note: There may be momentary and spasmodic orange flashes in the flame. This is caused by the burning of airborne dust particles, and should not be confused with the yellow tipping, which is a stable or permanent situation when there is insufficient primary air. 28 GAND-SVX01B-EN