Download Bosch 15SBI Technical data

Transcript
Table 5
PERFORMANCE SPECIFICATIONS
PRIMARY WATER CAPACITY
2.0 litres
MAXIMUM MAINS INLET PRESSURE
10 bar
MAXIMUM CENTRAL HEATING FLOW TEMPERATURE
85°C (nom)
MAXIMUM CENTRAL HEATING SYSTEM SET PRESSURE
2.5 bar
MINIMUM CENTRAL HEATING SYSTEM SET PRESSURE
0.5 bar
OUTPUT TO CENTRAL HEATING
NATURAL GAS (G20)
15SBi 6.0 - 15.0kw
24SBi 15.0 - 24.0kw
LPG - PROPANE (G31)
15SBi 6.0 - 15.0kw
24SBi 15.0 - 24.0kw
NOx CLASSIFICATION FOR BOTH 15 & 24SBi
Class 2
SEDBUK Rating
15SBi - Band D - 79.1% 24SBi - Band D - 78.3%
Table 6
GAS SUPPLY SYSTEM - BASED ON NG (G20)
TOTAL LENGTH OF GAS SUPPLY PIPE (COPPER) metres
3
6
9
12
GAS DISCHARGE RATE - PRESSURE DROP mbar. m3/h PIPE DIAMETER mm
8.7
5.8
4.6
3.9
22
18.0
12.0
9.4
8.0
28
Table 7
CLEARANCES
(mm)
INSTALLATION
ABOVE APPLIANCE FLUE ELBOW
30
IN FRONT OF APPLIANCE
600
BENEATH APPLIANCE
200
RIGHT AND LEFT HAND SIDE
10
SERVICE
30
600
200
10
Refer to Section 6.
Table 8
INITIAL
PRESSURE bar
1.0
1.5
SYSTEM CAPACITY
TOTAL SYSTEM VOLUME litres
INITIAL CHARGE PRESSURE bar
0.5
1.0
1.5
72
92
N/A
39
53
64
5