Download Monogram ZV54I Specifications

Transcript
p e r s p e c t i v e s
D e s i g n G u i d e A GE M O N O GR A M PU B L IC ATI O N As an ENERGY STAR® partner, GE has determined that the appliances marked with
the ENERGY STAR logo meet the ENERGY STAR guidelines for energy efficiency.
Before purchasing an ENERGY STAR qualified appliance, read important information
about its estimated annual energy consumption or energy efficiency rating that is
available from your retailer, monogram.com or www.energystar.gov.
Product improvement is a continuing endeavor at GE. Therefore, materials,
appearance and specifications are subject to change without notice.
2007
© 2007 GE Company Publication Number 24-M577 PC49881
perspectives
monogram 2007 design guide
Exceptional service is a Monogram standard.
Monogram® offers a feature no other brand can match: customized services that begin
before you’ve selected your appliances and continue until well after your Monogram
home has become a reality. The Monogram Collection™, a superb line of kitchen
appliances with a package of services to match.
Visit monogram.com. Find Monogram product information, specifications, installation
instructions and owner’s manuals. Also, schedule services and order parts online, anytime.
GE QuickSpecs, 800.432.3729. Request dimensions and specifications on any
Monogram appliance and have the data transmitted, within minutes, to the
fax number you provide.
Monogram Preferred Service, 800.444.1845. If your Monogram appliance should ever
require service, you can depend on Monogram Preferred Service. Simply call the above
number 7 a.m. - 10 p.m. EST, Monday through Friday, 8 a.m. - 6 p.m. EST, Saturday and
Sunday, to schedule your service appointment.
GE Answer Center®, 800.626.2000. For product assistance and answers to your
questions about Monogram appliances, 6:00 a.m. – 12:00 a.m. Monday through Saturday.
monogram.com
GE Monogram Design Guide
Monogram appliance planning:
®
from inspiration to installation.
Table of content s
3 Introduction
4 Refrigeration
Built-in side-by-side refrigerators
Built-in bottom-freezer refrigerators
Now more than ever, the kitchen is the heart
of the home. It’s the place where we relax and
gather in the company of family and friends.
That’s why, when you build a new home or
4–11
12–19
Built-in all-refrigerators and all-freezers20–23
Stainless steel-wrapped free-standing refrigerators24–25
Customization options26
27 Refrigeration modules
Double-drawer refrigerator27–28
Fresh-food and bar refrigerator29–30
remodel, the kitchen becomes the center of
your plans. It serves as your canvas for
artistic expression.
The Monogram Design Guide makes
Outdoor/indoor refrigerator31–32
Wine reserve and beverage center33–35
36 Icemakers and compactors
40 Dishwashers
43 Professional ranges
48" dual-fuel professional ranges
43–44
36" dual-fuel professional ranges
45–46
the kitchen—and throughout the home. With
30" dual-fuel professional ranges
47–48
detailed information on product specifications,
it easy to express your creative vision in
dimensions and installation, the Monogram
Design Guide helps bring your home design
plans to life.
Whether you’re a designer, builder,
architect or do-it-yourselfer, you’ll find
everything you need to select and install
Monogram appliances, including many
exciting options for customization. Should
you require additional planning guidelines
49 Gas cooktops
48" gas cooktops
49–50
36" gas cooktops
51–52
53–55
Stainless steel and gas-on-glass gas cooktops
56 Induction and electric cooktops
Induction cooktops
56–57
Digital electronic and electric cooktops
58–59
60 Ventilation systems
Chimney hoods
61–71
Professional hoods
72–78
Custom hood inserts
79–80
Telescopic downdraft vents
81–86
87 Wall ovens
Electronic wall oven with Trivection® technology
87
Integrated and professional convection wall ovens
88–89
and resources, simply visit us online at
Electronic convection wall oven
90–91
monogram.com.
93 Companion cooking products
Wall oven with Advantium® Speedcook technology
93–95
Microwave ovens
96–97
Warming drawers
98–99
36" outdoor cooking centers
Dual-burner cooktop
100–101
102
Built-in side-by-side refrigerators
DOOR
ALARM
CONTROL
LOCK
DOOR
ALARM
CONTROL
LOCK
48" built-in refrigerator
with dispenser
48" built-in professional
refrigerator with dispenser
48" built-in refrigerator
ZISW480DR,
ZISB480DR,
ZISB480DM.EPS
ZISS480DRSS*
ZISP480DTSS*
ZIS480NR, ZISS480NRSS*
ZISB420DM.EPS
ZISW420DR,
ZISB420DR,
ZISS420DRSS*
Overall dimensions
(WxHxD in inches):
48 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
775
Overall dimensions
(WxHxD in inches):
48 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
775
Overall dimensions
(WxHxD in inches):
48 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
775
Overall dimensions
(WxHxD in inches):
42 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
725
• 30.7 cu. ft. capacity
• Energy STAR qualified
• Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged
unified grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door panels required on
custom models
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
• 30.7 cu. ft. capacity
• Energy STAR qualified
• Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged
unified grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Professional handles
• 30.6 cu. ft. capacity
• Energy STAR qualified
• Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged
unified grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door panels required on
custom models
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
• 26.1 cu. ft. capacity
• Energy STAR qualified
• Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door panels required on
custom models
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
ZISW480DM.EPS
ZISP480_A10911.EPS
*Stainless steel-wrapped doors
ZIS480NM.EPS
42" built-in refrigerator
with dispenser
ZISW420DM.EPS
*Stainless steel-wrapped doors
*Stainless steel-wrapped doors
*Stainless steel-wrapped doors
For kosher kitchens, an optional kit allows Monogram
side-by-side refrigerators and bottom-freezer
refrigerators to run in Sabbath mode.
monogram.com
B u i l t- i n s i d e - b y - s i d e
refrigerators
Built-in side-by-side refrigerators
DOOR
ALARM
CONTROL
42" built-in professional
refrigerator with dispenser
ZIS420_A10913.EPS
ZISP420DTSS*
42" built-in refrigerator
ZISS420NM.EPS
ZIS420NR, ZISS420NRSS*
36" built-in refrigerator
with dispenser
ZISW360DM.EPS
ZISB360DM.EPS
ZISW360DR,
ZISB360DR,
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
LOCK
36" built-in refrigerator
ZIS360NM.EPS
ZIS360NR, ZISS360NRSS*
Overall dimensions
(WxHxD in inches):
42 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
725
Overall dimensions
(WxHxD in inches):
36 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
675
Overall dimensions
(WxHxD in inches):
36 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
675
• 26.1 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Professional handles
• 26.0 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door panels required on
custom models
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
• 21.7 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door panels required on
custom models
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
• 21.6 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinges
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door panels required on
custom models
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
*Stainless steel-wrapped doors
*Stainless steel-wrapped doors
*Stainless steel-wrapped doors
*Stainless steel-wrapped doors
Free -standing side - by-side
refrigerators
Overall dimensions
(WxHxD in inches):
42 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
725
B u i l t- i n a l l - r e f r i g e r a t o r s
all-freezers
ZISS360DRSS*
General features
Customization. Monogram® built-in custom refrigerators
require door and grille panels available from your Monogram
dealer. They also accept custom overlay panels and handles.
ENERGY STAR® qualified. As an ENERGY STAR partner, GE has
determined that all Monogram side-by-side refrigerators meet
the ENERGY STAR guidelines for energy efficiency.
Direct airflow. Cool air is delivered straight from the overhead
evaporator to freezer and fresh food compartments, allowing
independent airflow for each food zone without any direct
air exchange.
Dispenser with proximity sensor. Tall design accommodates
glassware of all sizes, from pitchers to tumblers. Control graphics
light up as you approach and automatically switch off when
you walk away.
Spacious interior. The overhead location of the evaporator
makes Monogram side-by-side refrigerators among the
largest-capacity built-in refrigerators available.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
Advance planning for built-in side-by-side refrigerators
Side-by-side refrigerators are available in 36", 42" and 48" widths. Design and installation considerations are the
same for all model widths.
Product dimensions
The installation space
36" Models 12"
42" Models 18"
48" Models 20"
Case Depth:
25-3/8" Framed Models
25-3/4" Stainless Steel Models
35", 41", or 47"
Case Width
*Finished Width
84-1/2" max
83-1/2" min
Finished
Opening
6"
Electrical
Area
5"
75" From Floor
to Bottom
of Electrical
Area
24"
5"
Water Supply 5" 3-1/2"
36", 42", or 48"
Frame to Frame
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
3-1/2"
Space is the first consideration when planning the installation.
* The finished cutout width must be:
35-1/2" min. for 36" wide models
41-1/2" min. for 42" wide models
47-1/2" min. for 48" wide models
696Dia15
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
The cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
*84" From
Floor to
Top Frame
*83-1/2"
at
Rear
*Shipping height. The refrigerator can be adjusted to fit into
a cutout that is 83-1/2" min. to 84-1/2" max. height. The top
case trim at the front is 1/2" higher and will overlap upper
cabinetry or soffit. Use leveling legs and wheels for
a maximum 1" height adjustment.
429Dia8
Door swing clearances
The installation must allow for clearances to adjacent walls or
cabinets. These refrigerators are equipped with a 2-position
door stop. The factory-set 130° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted. Order
WX14X99 door stop for precise settings between 90° and 130°.
A
B
130° Door Swing
90° Door Swing
The serial plate is located above the freezer compartment and
behind the grille panel.
C
Note: GFI (ground fault interrupter) is not recommended.
Water line
All models are equipped with an automatic icemaker. The
water line can enter the opening through the floor or back
wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing
between the cold water line and the water connection
location. The tubing should be long enough to extend to the
front of the refrigerator. The installation of an easily accessible
shut-off valve in the water line is required.
23-7/8"
Behind
Frame
4" Min. to Wall
5" Min. for Professional Models
Models
36"
42"
48"
A
B
C
15"20-5/8"
13"
19"26-5/8"
15"20"28-5/8"
605Dia413"
605Dia5
Observe all minimum clearances shown above for a 130° or 90°
door swing. A 90° door swing allows pan access, but removal is
restricted.
• See door swing illustrations to determine interaction with
adjacent cabinets or countertops.
monogram.com
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in side-by-side refrigerators
Customization basics: Framed or overlay panels, custom handles and accessor y kits
ZISP480DTSS, ZISP420DTSS
Stainless steel wrapped refrigerators with professional
handles and chamfered door edges. These models are
shipped ready for installation.
Overlay panels
You may also choose to install custom overlay panels
from your cabinet manufacturer. This design provides a
seamless appearance which integrates smoothly with
surrounding cabinetry.
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
Built-in stainless steel side-by-side refrigerators with
professional styling
Built-in stainless steel side-by-side refrigerators with
integrated styling
ZISS360NRSS, ZISS360DRSS
ZISS420NRSS, ZISS420DRSS
ZISS480NRSS, ZISS480DRSS
ZIS360NR, ZISW360DR, ZISB360DR
ZIS420NR, ZISW420DR, ZISB420DR
ZIS480NR, ZISW480DR, ZISB480DR
Custom panel refrigerators are designed to be customized
with decorative panels. Field-installed custom door and grille
panels are required.
Framed panels
You may install 1/4"-thick custom panels from your cabinet
manufacturer. The decorative panels slide into the factoryinstalled trim. Or, order black or stainless steel accessory
panels from your Monogram dealer.
1/4" Thick Backer Panel
Standard supplied handles shown in 3/4" overlay panel position.
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
Custom panel refrigerators
3/4" Overlay Panel
.10" Thick Spacer Panel
Door handles
The supplied handles can be adjusted to accommodate both
framed or overlay panels. Custom handles of your choice,
supplied by your cabinetmaker, can also be installed. If
desired, you may order ZKHSS2 Monogram stainless steel
tubular handle kit for overlay panels.
696Dia2
Side panels
Side panels must be used whenever the sides of the
refrigerator will be exposed.
Optional accessory kit
ZKHSS2: Tubular stainless steel handles designed to fit
3/4" overlay panels.
Free -standing side - by-side
refrigerators
Integrated stainless steel refrigerators have wrapped doors
and grille panel, beveled edges and tubular stainless steel
handles that coordinate with other Monogram® appliances.
These models are shipped ready for installation.
Accessory panels
Black acrylic and stainless steel accessory panels are available
from your Monogram supplier. Panels are cut to size and
ready to install. These panel kits must be ordered separately.
Framed Panel
Standard supplied handles shown in 1/4" panel position.
605Dia6
Black
Stainless
Models
acrylic
steel
ZISW480DZPS480D
ZISB480DZPB480DZPS480D
ZIS480NZPB480NZPS480N
ZISW420DZPS420D
ZISB420DZPB420DZPS420D
ZIS420NZPB420NZPS420N
ZISW360DZPS360D
ZISB360DZPB360DZPS360D
ZIS360NZPB360NZPS360N
Advance planning for built-in custom side-by-side refrigerators
3/4" overlay panel dimensions
For a more custom appearance,
overlay panels may be installed
on trimmed models. The overlay
panel must be secured to a
1/4"-thick backer panel which
slides into the trim. A spacer
panel 0.10" thick must be
placed between the overlay
and backer panels.
Raised overlay panel design
on dispenser models
Door
Center each panel over
the other. Assemble the
panels with glue and
screws. Screws must be
countersunk into
the backer panel.
3/4"
Overlay
Panel
• The middle rail must be wide enough to allow for the
dispenser trim to overlap the opening.
• The middle rail must be 1.100" total thickness to accept the
dispenser trim.
1/4" Backer Panel
.10" Spacer
3/4" Overlay Panel
1/4"
Backer
Panel
.250" + .10" + .750" = 1.100"
Total panel thickness
When a raised panel design is to be used, a custom wide
middle rail is required to accept the dispenser trim.
.10"
Spacer
Overlay Panel
194Dia58
Spacer Panel
Dispenser
Trim
Wide
Middle
Rail is
Required
16-3/4"
Backer Panel
Note: Left-to-right offset
is not always equal to
top-to-bottom offset.
10-5/8"
Side view
194Dia65
A
Grille Panel
Dispenser
Cutout
36" side-by-side (in inches)
A
1/4" backer panel33-7/8
.10" spacer panel33
3/4" spacer panel34-1/8
B
F
C
G
Freezer
Panel
Fresh Food
Panel
D
E
Dispenser Cutout
15-3/8"
9-5/8"
*Cut the dispenser opening after the backer, spacer and
overlay panels have been assembled.
194Dia64
B
C
8-3/8
9-1/4
D
14-9/16
67
13-1/4
68-5/8 14-13/16
42" side-by-side (in inches)
A
1/4" backer panel39-7/8
.10" spacer panel39
3/4" spacer panel 40-1/8
B
9-1/2
8-5/8
9-3/4
C
68-3/8
67
68-5/8
D
E
14-9/1624-9/16
13-1/423-1/4
14-13/1624-13/16
48" side-by-side (in inches)
A
1/4" backer panel 45-7/8
.10" spacer panel 45
3/4" spacer panel 46-1/8
B
9-1/2
8-5/8
9-3/4
C
68-3/8
67
68-5/8
D
E
18-9/1626-9/16
17-1/425-1/4
18-13/1626-13/16
194Dia82
9
68-3/8
194Dia63
Important note: Maximum weight for fresh food panel is 75
pounds, 53 pounds for freezer panel and 18 pounds for the
grille panel.
*Dispenser cutout position (in inches)
F
G
36" models
17-15/163-1/4
42" models
17-15/163-1/4
48" models
17-15/16 5-1/4
E
18-9/16
17-1/4
18-13/16
monogram.com
If you choose to install framed
panels, they must be cut to the
dimensions shown. The panels
will slide into the frame on the
door and grille.
Dispenser models
5/16"
Trim
Reveal
Door
1/4"
Panel
If the custom panel is less than
1/4" thick, and it fits loosely in
the door frame, it can be backed
up with a piece of filler material
or foam tape to improve the fit.
1/4" framed panel
The framed panel must be 1/4" nominal thickness to fit the
dispenser trim.
• The dispenser trim fits over the custom panel and snaps into
the freezer door.
• If the panel is less than 0.250" thick, a noticeable gap may be
created around the dispenser trim. Foam tape may be applied
on the door to improve the fit.
Important note: Maximum
weight for fresh food panel is 75
pounds, 53 pounds for freezer
panel and 18 pounds for the
grille panel.
• If the panel is more than 0.250" thick, the dispenser trim
cannot be secured to the door.
194Dia59
A
1/4"
Framed
Panel
B
FREEZER DOOR
0.250"
Thick
Ice / Water Dispenser
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
Grille Panel
These refrigerators are supplied with two dispenser trims, one for
framed panels and one for overlay panels.
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
1/4" framed panel dimensions
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in custom side-by-side refrigerators
1/4" Dispenser Trim
F
3/4" overlay panels
Freezer
Panel
D
• If the panel is less than 1.100" thick, a noticeable gap may
be created around the dispenser trim.
15-3/8"
Fresh Food
Panel
9-5/8"
E
Side-by-side (in inches)
A
36" models33-7/8
42" models39-7/8
48" models 45-7/8
194Dia64
696Dia3
Dispenser Cutout
C
G
The overlay dispenser trim is designed to fit a total panel
thickness of 1.100".
B
9
9-1/2
9-1/2
C
68-3/8
68-3/8
68-3/8
Dispenser cutout position (in inches)
F
G
36" models 17-13/163-1/8
42" models 17-13/163-1/8
48" models 17-13/16 5-1/8
D
E
14-9/16 18-9/16
14-9/1624-9/16
18-9/1626-9/16
194Dia63
• If the panel is more than 1.100" thick, the dispenser trim
cannot be secured to the door.
• The overlay panel must be constructed according to the
specifications shown to achieve the correct total thickness.
Free -standing side - by-side
refrigerators
Dispenser
Cutout
• Alternative panel construction methods such as
securing a 3/4" panel to a 1/4" backer panel cannot be used.
Another method, routing a 3/4"-thick panel on all sides,
cannot be used. These methods will not result in the required
1.100" panel thickness.
• When a raised panel design is to be used, a custom middle
rail is required. See page 8 for details.
1/4" Backer Panel
FREEZER DOOR
.10" Spacer
Panel
1.100"
Total
Thickness
Ice / Water Dispenser
3/4" Overlay
Panel
3/4" Overlay Dispenser Trim
696Dia4
Advance planning for built-in custom side-by-side refrigerators
Frameless cabinets: The case trim overlaps cabinets at the
top and sides. Therefore, frameless cabinets may require filler
strips to prevent interference with cabinet door swing. The
opening must allow for filler strips.
Use this page to determine door
swing interaction with adjacent
cabinets or countertops.
Refrigerator
23-7/8" From
Rear of
Refrigerator
Case
Trim
3/4"
1/2"
1/4"
1"
1-3/4"
2"
1-1/2"
2-3/4"
3"
2-1/2"
1-1/4"
2-1/4"
1/4"
1/2"
3/4"
1"
l
tee
sS
les
ain
St
3/4" Overlay
Panel
(Nominal Size)
Door
Top view
130° door swing
(Factory setting)
Scale 1:1
IMPORTANT NOTE – FOR DISPENSER MODELS
10
Dispenser models are supplied with two dispenser
trims, one to fit framed panels and one for overlay
panels. Dispenser trim fit to the custom panel depends
on correct panel thickness. Framed panels must be 1/4"
nominal. Overlay panels should be constructed as shown
to accomplish a total 1.100" thickness.
1/4"
1/2"
3/4"
1"
1-1/4"
monogram.com
Use this page to determine door
swing interaction with adjacent
cabinets or countertops.
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in custom side-by-side refrigerators
Refrigerator
Case Trim
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
23-7/8"
From Rear of
Refrigerator
Frameless Cabinets: The case trim overlaps
cabinets at the top and sides. Therefore,
frameless cabinets may require filler strips to
prevent interference with cabinet door swing.
The opening must allow for filler strips.
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
1/4"
1/2"
3/4"
1"
1-1/4"
IMPORTANT NOTE –
FOR DISPENSER MODELS
Dispenser models are supplied with
two dispenser trims, one to fit framed
panels and one for overlay panels.
Dispenser trim fit to the custom
panel depends on correct panel
thickness. Framed panels must
be 1/4" nominal. Overlay panels
should be constructed as shown to
accomplish a total 1.100" thickness.
Stainless Steel
Top view
90° door swing
(Optional setting)
Scale 1:1
Free -standing side - by-side
refrigerators
1-1/2"
Door
3/4" Overlay
Panel
(Nominal Size)
1/4"
1/2"
3/4"
1"
1-1/4"
11
Built-in bottom-freezer refrigerators
General features
Customization. Monogram®
built-in custom refrigerators
require door and grille panels.
These models also accept
framed or overlay custom
panels from your cabinetmaker.
Stainless steel–wrapped
models are shipped ready
for installation.
Temperature management
system. The temperature
management system with
upfront electronic controls
delivers cool, fresh air to
every shelf.
Flexible storage. In the freshfood compartment, four split
shelves and six adjustable door
bins offer convenient access
to contents. The large fullextension freezer drawer has an
automatic icemaker and storage
bins that slide out independently
of one another for easy loading
and unloading.
ENERGY STAR® qualified.
As an ENERGY STAR partner,
GE has determined that all
Monogram bottom-freezer
refrigerators meet the
ENERGY STAR guidelines
for energy efficiency.
For additional details on
product installation,
warranty coverage, care
and maintenance, visit
monogram.com.
12
36" built-in stainless
steel refrigerators
ZICS360NM.EPS
36" built-in professional
refrigerators
ZICP360_A10617.EPS
36" built-in
refrigerators
ZIC360NMRH.EPS
ZICS360NRRH, ZICS360NRLH
ZICP360SLSS, ZICP360SRSS
ZIC360NRRH, ZIC360NRLH
Overall dimensions
(WxHxD in inches):
36 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
675
Overall dimensions
(WxHxD in inches):
36 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
675
Overall dimensions
(WxHxD in inches):
36 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
675
• 20.6 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinge
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Stainless steel-wrapped doors
• Trimmed (semi-flush)
installation
• Door swing preference must
be specified
• Unified grille kit for
side-by-side installation
of two bottom-freezer
refrigerators
• 20.6 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinge
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Stainless steel-wrapped
doors, professional handles
and louvered grille panel
• Trimmed (semi-flush)
installation
• Door swing preference must
be specified
• 20.6 cu. ft. capacity
• Energy STAR qualified • Equipped to accept optional
Sabbath mode kit, zsab1
• Concealed door hinge
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
• Door swing preference must
be specified
• Door panels required
• No kits required for
customization
• Two-position handle adjusts
to accommodate 1/4" framed
or 3/4" overlay panels
• Unified grille kit for
side-by-side installation
of two bottom-freezer
refrigerators
Note: These professional
bottom-freezers are not
designed for side-by-side or
unified installations.
For kosher kitchens, an optional kit allows Monogram
side-by-side refrigerators and bottom-freezer
refrigerators to run in Sabbath mode.
monogram.com
B u i l t- i n s i d e - b y - s i d e
refrigerators
Built-in 72" professional bottom-freezer refrigerators
General features
Professional appearance. Professional commercial-grade
stainless steel appearance with professional handles and
chamfered edges. The full-width grille panel and toekick
provides a smooth and impressive statement. A "U" shaped
trim strip covers the space between the middle case trims for
a perfectly finished look.
ZICP720_A10616.EPS
ZICP720SSS*
Overall dimensions
(WxHxD in inches):
72 x 84 x 23-7/8 (behind frame)
115 Volts/20 Amps
Approx. shipping wt. (lbs.) 1,350
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
72" professional
bot tom-freezer
refrigerators
• 41.2 cu. ft. capacity
• Equipped to accept optional
Sabbath mode kit, zsab1 (2)
• Concealed door hinge
• Easy access hinged grille
• Four-point leveling system
• Adjustable door stop
(90°/130°)
• Trimmed (semi-flush)
installation
Free -standing side - by-side
refrigerators
Flexible storage. In the fresh-food compartments, four
split shelves and six adjustable door bins on each side offer
convenient access to contents. Large full-extension freezer
drawers have automatic icemaker and storage bins that
slide out independently of one another for easy loading and
unloading.
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
Temperature management system. The temperature
management system with upfront electronic controls delivers cool,
fresh air to every shelf.
*This product consists of 3
SKU's. You must order all 3
SKU's to complete this product:
1. ZICP720SSS: Unified grille,
toekick and parts
2.ZICP720ASSS: refrigerator, left-side
3.ZICP720BSSS: refrigerator, right-side
13
Advance planning for built-in bottom-freezer refrigerators
The installation space
Door swing clearances
The finished cutout width must be 35-1/2".
The installation must allow for clearances to adjacent walls or
cabinets. These refrigerators are equipped with a 2-position
door stop. The factory-set 130° door swing can be adjusted
to 90° if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between 90°
and 130°.
35-1/2"
Finished Width
Wall View
2-5/16"
6"
10"
84-1/2" max
83-1/2" min
Finished
Opening
Electrical
Area
75" From
Floor to Bottom
of Electrical
Area
24" Cutout Depth
5" Water Supply
25"
Min. to
Wall
130° Door Swing
90° Door Swing
23-7/8"
Behind
Frame
5"
36-3/4"
3 1/2"
3 1/2"
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
The cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
696Dia7
Note: GFI (ground fault interrupter) is not recommended.
Water line
All models are equipped with an automatic icemaker. The
water line can enter the opening through the floor or back
wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing
between the cold water line and the water connection
location at the front of the refrigerator. The installation of an
easily accessible shut-off valve in the water line is required.
Product dimensions
35"
Case Width
14
36"
Frame to Frame Width
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
429Dia9
4" Min. to Wall
5" Min. for Professional Models
605Dia20
Observe all minimum clearances shown above for a 130° or
90° door swing. A 90° door swing allows pan access, but
removal is restricted.
605Dia21
• 4" minimum clearance is required when the door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
• See door swing illustrations to determine interaction with
adjacent cabinets or countertops.
ZUG2, ZUGSS2 unified grille panel kit
• If you are installing two refrigerators side by side, the
installation space must be 71-1/2" wide.
Note: Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width.
• The water and electrical locations for each product must
be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
Case Depth:
25-3/8" Framed Models
25-3/4" Stainless Steel Models
*84" From
Floor to
Top Frame
*83-1/2"
at
Rear
90°
130°
*Shipping height. The
refrigerator can be
adjusted to fit into a
­cutout that is 83-1/2" min.
to 84-1/2" max. height.
The top case trim at
the front is 1/2" higher
and will overlap upper
cabinetry or soffit.
Use leveling legs and
wheels for a maximum
1" height adjustment.
71-1/2" Finished Width
2-5/16"
10"
10"
84-1/2" max
83-1/2" min
Finished
Opening
Wall View
24-3/16"
6"
Electrical
24" Cutout
Depth
5" Water Supply
3-1/2"
26"
Water Supply 5"
26"
75" From
Floor to Bottom
of Electrical
Area
3-1/2"
The serial plate is located inside the fresh food compartment,
below the bottom storage drawer on the right side.
696Dia8
monogram.com
The installation space
Corner installation
The finished cutout width must be 71-1/2".
• These refrigerators are equipped with a 2-position door stop.
The factory set 130° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
Electrical
6“
10“
10“
24“ Cutout
Depth
5“
3-1/2“
Water Supply
26“
Water Supply
26“
5“
75“ From
Finished
Floor to
Bottom of
Electrical
Area
• Order WX14X99 door stops for precise settings between 90°
and 130°. Order 2 doors stops, one for each door.
25"
Min. to
Wall
0"
130° Door
Swing
130° Door
Swing
25"
Min. to
Wall
3-1/2“
Note: The case trim overlaps cabinets at the top an sides.
Frameless cabinets may require filler strips to prevent
interference with cabinet door swing. The opening width must
allow for filler strips. See installation instructions for details.
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Electrical
Separate 115V, 60Hz., 15 or 20 amp power supply with individual
properly grounded branch circuits or circuit breakers are
recommended. Install properly grounded 3-prong electrical
receptacles recessed into the back wall. Electrical must be
located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water line
Both refrigerators are equipped with an automatic icemaker.
The water lines can enter the opening through the floor or
back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper
tubing between the cold water line and the water connection
location at the front of the refrigerator. The installation of an
easily accessible shut-off valve in the water line is required.
Allow 25" minimum clearance for a full 130° door swing.
Allow 15" for pan removal.
695Dia3
5" minimum clearance is required
when door swing is adjusted to
90°. If the 90° door stop position
is use, pan access is maintained,
but pan removal is restricted.
90° Door Swing
23-7/8"
Behind
Frame
B u i l t- i n a l l - r e f r i g e r a t o r s
all-freezers
84-1/2“
max
83-1/2“
min
Finished
Opening
Wall
View
24-3/16“
6“
36-3/4"
90°
5" Min.
to Wall
Free -standing side - by-side
refrigerators
2-5/16“
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
71-1/2“ Finished Width
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for 72" professional bottom-freezer refrigerators
zicp_bf_ref_qs_art
Product dimensions
71-1/2"
Case Width
25-3/4"
Case Depth
84"*
83-1/2"
at Rear
*Shipping height. The
refrigerators can be adjusted
to fit into a cutout that is
83-1/2" min. to 84-1/2" max.
Note that the top case trim
at the front is 1/2" higher and
will overlap upper cabinetry
or soffit. Use leveling legs
and wheels for a maximum
1" height adjustment.
72" Frame to
Frame Width
28-11/16" Depth
Including Handles
15
Advance planning for built-in bottom-freezer refrigerators
Customization basics: framed or overlay panels, custom handles
and accessor y kits
These bottom-freezer refrigerators are factory set for a left or right door swing.
The door swing is NOT reversible. Choose an RH model with hinge on the right
side; the door swings left to right. Choose an LH model with hinge on the left
side; the door will swing right to left.
Right-hand
door swing
Left-hand
door swing
Professional refrigerators
ZICP360SLSS, ZICP360SRSS
Stainless steel wrapped refrigerators with professional handles,
louvered grille panel and chamfered door edges. These models
are shipped ready for installation.
Stainless steel refrigerators
ZICS360NRLH, ZICS360NRRH
Stainless steel refrigerators have wrapped doors and grille panel,
beveled edges and tubular stainless steel handles. These models
are shipped ready for installation.
Custom refrigerators
ZIC360NRLH, ZIC360NRRH
Custom refrigerators are designed to be customized with
decorative panels. Field-installed custom door and grille
panels are required.
Framed panels
You may install 1/4"-thick custom panels from your ­cabinet
manufacturer. The decorative panel or accessory panel slides
into the factory-installed trim.
Door handles
The supplied handles can be adjusted to accommodate both
framed or overlay panels. Custom handles of your choice,
supplied by your cabinetmaker, can also be installed. If desired,
you may order ZKHCSS2 Monogram® stainless steel tubular
handle kit for overlay panels.
605Dia26
Side panels
Side panels must be used whenever the sides of the
refrigerator will be exposed.
Optional accessory kits
ZKHCSS2: Monogram stainless steel tubular handle kit
and handle side trim for custom handles. For use on
3/4" custom panels.
ZKHCT: Handle side trim kit for left-hand and right-hand doors.
For use on 3/4" custom panel when using a custom handle.
ZUG2: For side-by-side installation of two trimmed bottomfreezer refrigerators. This kit provides for the installation of a
unified custom grille panel to span the width of two units using
a framed or overlay panel.
ZUGSS2: For side-by-side installation of two stainless
steel–wrapped bottom-freezer refrigerators. This kit
provides a unified stainless steel grille panel to span the
width of two units.
Standard Door Handle
Framed Panel
Standard supplied handles shown in 1/4" panel position.
Overlay panels
You may also choose to install custom overlay panels
from your cabinet manufacturer. This design provides a
seamless appearance which integrates smoothly with
surrounding cabinetry.
729Dia65
Standard
Door Handle
16
3/4" Overlay Panel
.10" Thick Spacer Panel
1/4" Thick Backer Panel
Standard supplied handles shown in 3/4" overlay
panel position.
Accessory panels
Black acrylic and stainless steel accessory panels are available
from your Monogram supplier. Panels are cut to size and ready
to install. These panel kits must be ordered separately.
Black
Stainless steel
ZPBC360ZPSC360
monogram.com
1/4"
Panel
If the custom panel is less than
1/4" thick, and it fits loosely in the
door frame, it can be backed up
with a piece of filler material or
foam tape to improve the fit.
Important note: Maximum
weight for fresh food panel
is 58 pounds, 28 pounds for
freezer drawer panel and 11
pounds for the grille panel.
B
Fresh Food
Panel
C
Freezer Drawer
Panel
Door/Drawer
1/4"
Backer
Panel
729Dia84
A
Grille Panel
For a more custom
appearance, overlay
panels may be installed
on trimmed models. The
overlay panel must be secured
to a 1/4"-thick backer panel
which slides into the trim. A
spacer panel 0.10" thick must
be placed between the overlay
and backer panel.
Overlay
Panel
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
Door/Drawer
5/16"
Trim
Reveal
.10 Inch
Spacer
.250" + .10" + .750" =
1.100" total panel thickness
729Dia42
Center each panel
over the other.
Assemble the
panels with glue
and screws.
Screws must be
countersunk into
the backer panel.
Overlay Panel
Spacer Panel
Backer Panel
Note: Left-to-right offset is not always equal to
top-to-bottom offset.
D
Free -standing side - by-side
refrigerators
If you choose to install framed
panels, they must be cut to the
dimensions shown. The panels
will slide into the frame on the
door, drawer and grille.
3/4" overlay panel dimensions
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
1/4" framed panel dimensions
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in custom bottom-freezer refrigerators
194Dia65
ZUG2 grille panel dimensions
Framed panel dimensions (in inches)
A (width) B (grille ht.)
1/4" framed panel33-7/8
8-7/8
729Dia89
3/4" overlay panel dimensions (in inches)
A (width) B (grille ht.)
1/4" backer panel33-7/8
8-7/8
.10" spacer panel32-1/2
7-5/8
3/4" overlay panel34-1/8
9
C (FF ht.) D (FZ ht.)
46-1/1621-7/8
The ZUG2 unified grille panel kit will accept a framed or
overlay grille panel.
• Assemble the overlay panel in the same manner
as the door and drawer panels.
A
C (FF ht.) D (FZ ht.)
46-1/1621-7/8
44-11/1620-1/2
46-5/1622
B
Grille Panel
Important: Grille panel maximum total weight is 25 lbs.
Framed panel dimensions
A (width)
1/4" framed panel
69-7/8"
B (height)
8-7/8"
Overlay panel dimensions
A (width)
1/4" backer panel
69-7/8"
.10" spacer panel
68-1/2"
3/4" overlay panel
70-1/8"
B (height)
8-7/8"
7-5/8"
9"
729Dia85
17
Advance planning for built-in custom bottom-freezer refrigerators
Frameless cabinets: The case trim overlaps cabinets at the
top and sides. Therefore, frameless cabinets may require filler
strips to prevent interference with cabinet door swing. The
opening must allow for filler strips.
Use this page to determine door
swing interaction with adjacent
cabinets or countertops.
Refrigerator
23-7/8" From
Rear of
Refrigerator
Case
Trim
3/4"
1/2"
1/4"
1"
1-3/4"
2"
1-1/2"
2-3/4"
3"
2-1/2"
1-1/4"
2-1/4"
1/4"
1/2"
3/4"
1"
l
tee
sS
les
ain
St
3/4" Overlay
Panel
(Nominal Size)
Door
18
Top view
130° door swing
(Factory setting)
Scale 1:1
1/4"
1/2"
3/4"
1"
1-1/4"
monogram.com
Use this page to determine door
swing interaction with adjacent
cabinets or countertops.
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in custom bottom-freezer refrigerators
Refrigerator
Case Trim
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
23-7/8"
From Rear of
Refrigerator
Frameless cabinets: The case trim overlaps
cabinets at the top and sides. Therefore,
frameless cabinets may require filler strips to
prevent interference with cabinet door swing.
The opening must allow for filler strips.
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
1/4"
1/2"
3/4"
1"
1-1/4"
Stainless Steel
Free -standing side - by-side
refrigerators
1-1/2"
Door
3/4" Overlay
Panel
(Nominal Size)
1/4"
1/2"
Top view
90° door swing
(Optional setting)
Scale 1:1
3/4"
1"
1-1/4"
19
Built-in custom all-refrigerators and all-freezers
ZIR36NDRH/ZIF36NDRH
ZIR36NDLH/ZIF36NDLH
All-refrigerator general features
Adjustable shelves and bins. Split shelves move up and down
for custom storage arrangement and raised edges help contain
spills. Six adjustable door bins (two for gallon-size containers)
add important storage flexibility. There are also two door dairy
­compartments that seal for longer freshness.
Produce and snack pans. Vegetable ­compartments with
individual humidity controls, as well as sealed snack pans,
glide open smoothly.
All-freezer general features
Adjustable shelves and bins. Five wire shelves move up and
down for custom storage arrangement. Ten adjustable door bins
(two for gallon-size ­containers) enhance storage flexibility.
Specialized storage baskets. Eight pullout wire baskets with
clear-view fronts (two with lids) allow compartmentalized storage
for different food types.
All-refrigerator and
all-freezer general features
Customization. Monogram® built-in custom all-refrigerators
and all-freezers require door and grille panels. Models can be
equipped with 1/4" door panels available from your Monogram
dealer (black Lexan® and stainless steel). Also available
is a unified-grille panel kit for either 3/4"-thick custom panels
or stainless steel wrap.
Left- or right-hinged door swing. Door-swing preference
must be specified when ordering. (Handles and hinges are
not reversible.)
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
36" built-in
all-refrigerator
36" built-in
all-freezer
ZIR36NMRH, ZIR36NMLH,
ZIRS36NMRH*, ZIRS36NMLH*
ZIF36NMRH, ZIF36NMLH,
ZIFS36NMRH*, ZIFS36NMLH*
Overall dimensions
(WxHxD in inches):
36 x 84 x 24-3/4
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
36 x 84 x 24-3/4
115 Volts/20 Amps
Approx. shipping wt. (lbs.)
675
• 21.9 cu. ft. capacity
• Four-point leveling system
• 130° door stop
• Coil-free back
• Flush or trimmed
(semi-flush) installation
• Trimmed models require door
and grille panels
• Trim kit required for 3/4"
trimless panels, custom
handles or installation heights
of 83-1/2" or 84-1/2".
• Door swing preference must
be specified
• Unified grille kits for
installation with 3/4" custom
panels or stainless steel
models
• 21.9 cu. ft. capacity
• Four-point leveling system
• 130° door stop
• Coil-free back
• Automatic icemaker
• Flush or trimmed
(semi-flush) installation
• Trimmed models require door
and grille panels
• Trim kit required for 3/4"
trimless panels, custom
handles or installation heights
of 83-1/2" or 84-1/2".
• Door swing preference must
be specified
• Unified grille kits for
installation with 3/4" custom
panels or stainless steel
models
*Stainless steel-wrapped doors
*Stainless steel-wrapped doors
20
675
monogram.com
The installation space
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in custom all-refrigerators and all-freezers
Product dimensions
24-3/4"
Electrical Outlet
Location 2-1/2"
Case Depth:
24-3/4"
B
A = 36", B = 35-1/2" for
semi-flush and 36" for
flush installations.
83-1/2"
To
84-1/2"
5"
Note: Icemaker
Water Connection
Is At The Front
Of The Freezer
Water Supply
5"
A
3-1/2"
Depth Including Handles:
26-1/4" Framed Models
26-3/4" Stainless Steel Models
3-1/2"
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
696Dia10
605Dia29
Door swing clearances
The installation must allow for clearances to adjacent walls or
cabinets. These refrigerators are factory set for a 130° door
swing. The door swing can be reduced to as little as a 90°
opening with an optional WX14X99 kit.
The serial plate is located inside the refrigerator/freezer below
the bottom storage drawer on the right side.
Note: GFI (ground fault interrupter) is not recommended.
Water line
The water line can enter the opening through the floor or
back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper
tubing between the cold water line and the water connection
location at the front of the freezer. The installation of an easily
accessible shut-off valve in the water line is required.
Leveling
The rear leveling wheels and front leveling legs are
limited to a maximum height adjustment of 1".
Side-by-side installations
When installing an all-refrigerator and all-freezer side by side,
the installation space must be 71-1/2" wide.
• Locate water and electrical as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply
is recommended for each product.
71-1/2" Finished Width
2-1/2"
28-1/2"
Electrical
Wall View
6"
5"
5"
84-1/2" max
83-1/2" min
Finished
Opening
24" Cutout
Depth
75" From
Floor to Bottom
of Electrical
Area
5" Water Supply
3-1/2"
*Shipping height.
Cabinet height may be
changed to 83-1/2" or
84-1/2" using ZGC2 grille
panel kit. The ZKTR36
kits for 3/4" thick panels
provide a grille panel
support for all heights.
130° Door Swing
25"
Min. to
Wall
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
24-3/4" Total Depth
*84"
75" From Floor
to Bottom
of Electrical
Area
90° Door Swing
36-3/4"
130°
90° door swing with optional WX14X99 door stop.
605Dia20
Free -standing side - by-side
refrigerators
5"
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
6"
4" Min.
to Wall
• Allow 25" minimum clearance for a full 130° door swing.
Allow 15" for pan removal.
605Dia32
• 4" minimum clearance is required when the door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
Clearances for multiple installations
When installing an all-refrigerator and all-freezer side by side,
allow 25" for a full 130° door swing, or 15" min. on the hinge
sides for pan removal.
0"
25"
25"
Min. to
Min. to
Wall
Wall
130° Door Swing
130° Door Swing
26"
Freezer
Refrigerator
21
696Dia12
Advance planning for built-in custom all-refrigerators and all-freezers
Customization basics: Framed or overlay panels, custom handles and accessory kits
These Monogram® all-refrigerators and all-freezers may be
installed flush or semi-flush with surrounding cabinetry. Cutout
dimensions, clearances and side panel sizes are determined
by the many installation options available.
The all-refrigerator and all-freezer models are factory set for a
left or right door swing. The door swing is NOT reversible. Choose
an RH model with hinge on the right side; the door swings left to
right. Choose an LH model with hinge on the left side; the door
will swing right to left.
Stainless steel–wrapped all-refrigerators
ZIRS36NMLH, ZIRS36NMRH
Stainless steel–wrapped all-freezers
ZIFS36NMLH, ZIFS36NMRH
Stainless steel–wrapped models have tubular stainless steel
handles that coordinate with other Monogram appliances.
These models do not accept custom panels or custom
handles. However, you may wish to change the installation
height or use a side-by-side kit.
Custom all-refrigerators
ZIR36NMLH, ZIR36NMRH
Custom all-freezers
ZIF36NMLH, ZIF36NMRH
Custom all-refrigerators are designed to be customized with
decorative panels. Field-installed custom door and grille
panels are required. Use one or more kits to accomplish a
wide range of appearance options. Trim kits must be ordered
separately from your Monogram supplier. See trim kit
descriptions at right.
Framed panels
You may install a 1/4"-thick custom panel from your cabinet
manufacturer. The decorative panel slides into the factoryinstalled trim. Black Lexan® and stainless steel accessory
panels are available from your Monogram dealer.
3/4" trimless panels
You may also choose to install a 3/4" custom overlay panel
from your cabinet manufacturer. This design provides a
seamless appearance which integrates smoothly with
surrounding cabinetry. A trim kit is required for a 3/4"
custom panel.
Door handles
The supplied handle can be replaced with a custom handle
of your choice on both 1/4" and 3/4" panels. The Monogram
tubular stainless steel handle is also available to fit the
chosen panel thickness. Custom handles should be supplied
by your cabinetmaker. Trim kits are required to support a
custom handle.
22
Optional trim kits
Door handle kits
ZKHR1: Provides the necessary framework to install a custom
handle of your choice onto a 1/4"-thick custom panel. (Handle
not included.)
ZKHTR1: Provides the necessary framework to install a custom
handle of your choice onto a 3/4"-thick custom panel. (Handle
not included.) This kit must be used in combination with
ZKTR36LH or ZKTR36RH.
ZKHRSS1: Tubular stainless steel handle for 1/4"-thick
panel installation.
ZKHTRSS1: Tubular stainless steel handle for 3/4"-thick panel
installation. This kit must be used in combination with ZKTR36LH
or ZKTR36RH.
Custom panel kits
ZKTR36LH for ZIR36NDLH, ZIF36NDLH
ZKTR36RH for ZIR36NDRH, ZIF36NDRH
Provides for the installation of 3/4" thick custom door and
grille panels. Use this kit for a trimless appearance. This kit
includes a standard handle to fit the 3/4" thick panel.
Height adjustment kit
ZGC2: Provides 1/4" grille panel frame side pieces for 83-1/2"
and 84-1/2" installation heights. (The supplied grille panel
frame is set for 84" installation height.)
Side-by-side kit
ZUG75: For side-by-side installation of two trimmed units.
This kit provides for the installation of a 3/4" unified custom
grille panel to span the width of two units. Includes a trim strip
to cover inside case trim for a finished appearance. This kit
must be used in combination with BOTH the ZKTR36LH and
ZKTR36RH custom panel kits.
ZUGSS side-by-side grille panel kit
For installation of two stainless steel units. This kit provides
a unified stainless steel grille panel to span the width of two
units. It includes a trim strip to cover the inside case trims for
a finished appearance.
Accessory panels
Black Lexan and stainless steel accessory panels are available
from your Monogram supplier. Panels are cut to size and ready to
install. These panel kits must be ordered separately.
Black
Stainless steel
ZWBR36ZWSR36
monogram.com
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for built-in custom all-refrigerators and all-freezers
Custom panel dimensions
A
Height
Rout for 3/4"
Handle Kits Only
See Details
Custom door panel sizes
SIZES
A
1/4" panels35-1/16"
3/4" panels35-1/16"
3/4" panels with
custom handle35-1/4"
605Dia37
3/4" grille panel dimensions
Order ZKTR36LH or ZKTR36RH panel kit. A grille panel support
is included with this trim kit and fits all installation heights.
B
68-7/8"
68-15/16"
3/4" custom grille panel
Panel width
Panel height to fit installation height
83-1/2" 84"
84-1/2"
35-1/4"
7-3/4"
8-1/4"
8-3/4"
605Dia39
68-15/16"
For Handle Kits Only
Rout Back Side of Panel
1-13/16"
1/4"
Max.
Width
Custom Grille Panels
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
B
1/4" custom grille panel
Panel width
Panel height to fit installation height
83-1/2" 84"
84-1/2"
35-1/8"
7-1/2"
8"
8-1/2"
Appearance Side
Rout the back side of the custom panel when ­installing a ZKHTR1
custom handle kit or ZKHTRSS1 tubular stainless steel handle kit.
ZUG75 grille panel dimensions
The ZUG75 grille panel kit should be used in combination with
both the ZKTR36LH and ZKTR36RH panel kits.
3/4" custom grille panel
Panel width
Panel height to fit installation height
83-1/2" 84"
84-1/2"
71-3/8"
7-3/4"
8-1/4"
8-3/4"
Free -standing side - by-side
refrigerators
Custom
Panel
Important note:
Maximum weight
for door panel is
67 pounds and
9 pounds for the
grille panel.
1/4" custom grille panel dimensions
The supplied grille panel frame is factory-assembled for 84"
installation height. Order ZGC2 grille panel kit when installation
height is more or less than 84".
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
Framed and 3/4" trimless panel dimensions
If you choose to install framed or 3/4" trimless panels,
they must be cut to the dimensions shown.
Width
ZUG75 Grille Panel
Height
Important: Grille panel maximum total weight is 18 lbs.
605Dia38
605Dia40
23
Free-standing stainless steel—wrapped refrigerators
General features
Allover stainless appearance.
At once dramatic and
restrained, Monogram®
stainless steel–wrapped
refrigerators are smooth
from edge to edge, with no
exposed screws or rivets.
For a built-in look, choose
the counter-depth model,
which aligns nearly flush with
surrounding cabinetry.
Climate-control drawer.
Functions like a refrigerator
within the refrigerator. Precise
controls allow you to expresschill beverages, express-thaw
meats and select specific
temperatures for perishable
foods.
Extra-tall dispenser.
Accommodates glassware
of all sizes, from pitchers to
tumblers.
Energy Star® qualified. As
an Energy Star partner, GE
has determined that these freestanding refrigerators meet the
Energy Star guidelines for
energy efficiency.
SmartWater™ filtration
system. Delivers clean, greattasting water and ice through
the dispenser.
For additional details on
product installation,
warranty coverage, care
and maintenance, visit
monogram.com.
24
QUICK
QUICK
ICE
ICE
RESET
WATER
RESET
FILTER
WATER
DOOR
CONTROL
FILTER
DOOR
ALARM
CONTROL
LOCK
ALARM
LOCK
36" free
-standing
ZFSB25DMSS.EPS
side -by-side
refrigerator
36" free
-standing
ZFSB25DMSS.EPS
side -by-side
counter- depth
refrigerator
36" free -standing
side -by-side
counter- depth
refrigerator
ZFSB26DRSS
ZFSB23DRSS
ZFSB25DTSS
Overall dimensions
(WxHxD in inches):
36 x 72 x 34
(including handles)
115 Volts/20 Amps
Approx. shipping wt. (lbs.) 490
Overall dimensions
(WxHxD in inches):
36 x 72 x 29-1/2
(including handles)
115 Volts/20 Amps
Approx. shipping wt. (lbs.) 460
Overall dimensions
(WxHxD in inches):
36 x 72 x 30-1/2
(including handles)
115 Volts/20 Amps
Approx. shipping wt. (lbs.) 493
• 25.5 cu. ft. capacity
• Energy STAR qualified
• Concealed door hinge
• 22.6 cu. ft. capacity
• Energy STAR qualified
• Concealed door hinge
• 24.6 cu. ft. capacity
• Energy STAR qualified
• Full height doors
• Concealed door hinge
monogram.com
B u i l t- i n s i d e - b y - s i d e
refrigerators
Advance planning for free-standing refrigerators
Door swing clearances
Product dimensions
32"
(34" Including
Handles)
27-1/2"
(29-1/2" Including
Handles)
The installation must allow for clearances to adjacent walls or
cabinets. These refrigerators are factory set for a 160° door swing.
ZFSB26, ZFSB25 and ZFSB23
14-1/4"
19"
160° Door Swing
B u i l t- i n b o t t o m - f r e e z e r
refrigerators
72"
72"
36"
36"
160°
zfsb26dRss
zfsb23dRss
28-1/2” Depth
(30-1/2"
Including
Handles
ZFSB26 ZFSB25 ZFSB23
605Dia43
28" 24-5/8" 24"
22"
22"
B u i l t- i n a l l - r e f r i g e r a t o r s
and all-freezers
90° Door Swing
22"
72"
4" Min.
to Wall
zfsb25dTss
Installation note:
Door and passageways into the installation location require a
36" minimum opening. If the opening is less than 36", the top
cap and doors must be removed. See installation instructions
for details.
605Dia44
• 4" minimum clearance is required when the door swing is
restricted to 90°.
Free -standing side - by-side
refrigerators
36"
Allow 19" minimum clearance on the fresh food side for a full
160° door swing and pan removal. Allow 14-1/4" clearance on
the freezer side for removal of ice bin.
Air circulation clearances
Allow 1/8" on each side and 1-1/2" at the top and back side for
proper air circulation.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall.
This serial plate is located inside the fresh food compartment,
at the top and on the right side.
Note: GFI (ground fault interrupter) is not recommended.
Water line
The water line can enter the opening through the floor or back
wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing
between the cold water line and the water connection location
at the rear of the refrigerator. The installation of an easily
accessible shut-off valve in the water line is required.
25
Custom options for refrigerators
48" side-by-side refrigerators
Models
Custom options
ZISW480DR
Glossary of terms
ZISB480DR
ZIS480NR
Stainless steel tubular handles
for overlay panelsZKHSS2ZKHSS2ZKHSS2
1/4" black acrylic panelsZPB480DZPB480N
1/4" stainless steel panelsZPS480DZPS480DZPS480N
Tubular stainless steel handles.
Monogram® stainless steel tubular
handles can be used with custom panels.
42" side-by-side refrigerators
Models
Custom options
ZISW420DR
ZISB420DR
ZIS420NR
Stainless steel tubular handles
for overlay panelsZKHSS2ZKHSS2ZKHSS2
1/4" black acrylic panelsZPB420DZPB420N
1/4" stainless steel panelsZPS420DZPS420DZPS420N
36" side-by-side refrigerators
Models
Custom options
ZISW360DR
ZISB360DR
ZIS360NR
Stainless steel tubular handles
for overlay panelsZKHSS2ZKHSS2ZKHSS2
1/4" black acrylic panelsZPB360DZPB360N
1/4" stainless steel panelsZPS360DZPS360DZPS360N
36" bottom-freezer refrigerators
Models
ZIC360NRRH ZIC360NRLH
Custom options
Stainless steel
tubular handles for
overlay panelsZKHCSS2ZKHCSS2
ZICS360NRRH
ZICS360NRLH
Unified grille kitZUG2ZUG2ZUGSS2ZUGSS2
1/4" black acrylic panelsZPBC360ZPBC360
1/4" stainless steel panelsZPSC360ZPSC360
Custom handle side
trim kit for 3/4"-thick
custom panelsZKHCTZKHCT
36" all-refrigerators and all-freezers
Models
All-refrigerators
All-freezers
Custom options
ZIR36NMRH
ZIF36NMRH
ZIR36NMLH
ZIF36NMLH
ZIRS36NMRH
ZIFS36NMRH
ZIRS36NMLH
ZIFS36NMLH
Stainless steel panels ZWSR36ZWSR36
Black Lexan panels ZWBR36ZWBR36
Custom handle kit for
framed 1/4"-thick panelsZKHR1ZKHR1
Tubular stainless steel
handles for 1/4"-thick panelsZKHRSS1ZKHRSS1
3/4"-thick custom panel kitZKTR36RHZKTR36LH
Custom handles for overlay
3/4"-thick custom panelsZKHTR1ZKHTR1
Tubular stainless steel
handles for 3/4"-thick
custom panelsZKHTRSS1ZKHTRSS1
Adjustable grille height kitZGC2ZGC2
Unified grille panel kit for
side-by-side installationZUG75ZUG75ZUGSSZUGSS
26
Stainless steel or black panels.
Factory-installed trim will accept
1/4"-thick accessory panels which are
cut to size and ready to install. These
panels must be ordered separately.
Unified grille panel kit.
An optional grille panel creates a unified
look above two units placed side by side.
Optional Sabbath mode product kit.
Designed for use on the Jewish
Sabbath and holidays, this kit allows
the refrigerator to operate but will not
respond to actions by the consumer.
This kit is available for use on builtin side-by-side and bottom freezer
refrigerators only.
monogram.com
Refrigeration modules
Double - drawer
refrigerator
Double - drawer refrigerator
general features
Temperature control. Digital touch controls maintain a
consistent temperature for the upper and lower drawers, and an
LED display allows you to monitor the temperature at a glance.
Interior lighting. Brilliant full-width LED lighting in both drawers
puts contents into clear view.
Flush installation. The built-in configuration allows nearseamless integration with surrounding cabinetry. Model
ZIDI240PII accepts custom 3/4" panel and handle for
a personalized look.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
Fr e s h - f o o d r e f r i g e r a t o r
bar refrigerator
Storage convenience. A fold-down shelf, adjustable dividers
and removable bottom-drawer bin maximize storage space and
flexibility, allowing room for everything from whole melons to
large turkeys. The top drawer can hold up to 72 twelve-ounce
cans, and the bottom drawer has room for eight two-liter bottles.
Double - drawer
ZIDS24OPSS
refrigerator
ZIDS240PSS—Stainless steel
ZIDI240PII—Custom panel
Overall dimensions*
(WxHxD in inches):
23-3/4 x 34-1/4 - 34-3/4 x 23-3/4
Amps @120 Volts
15
Approx. shipping wt. (lbs.)
126
O u t d o o r/ i n d o o r
refrigerator
• Designed to be built-in only.
Cannot be used free-standing
• Factory-installed black toekick,
stainless toekick included
• Trimmed model designed
to be customized with custom
panel and handle
• Both designs can be installed
flush in standard 24” deep
cabinets
W ine re se r ve, wine c hille r
b eve rage ce nte r
*Height excluding legs, depth
excluding handle
Advance planning for double-drawer refrigerator
The installation space
Locate Outlet
The Monogram® double-drawer refrigerator must
be installed below a countertop. It cannot be used
free-standing.
Note: When installed, model ZIDI240PII with 3/4" custom drawer
panels and model ZIDS240PSS with stainless steel wrapped
drawers will be flush with adjacent 24"-deep cabinets.
10-1/2"
34-1/2"-35"
9"
Max.
1-1/2"
23-3/4" Min.
24" Min.
23-3/4" Stainless Steel
Models
24-7/8" Framed Models
Depth Including
Handles:
25-7/8" Stainless
Steel Models Only
34-1/4" - 34-3/4"
23-3/4"
27
Advance planning for double-drawer refrigerator
Location requirements
All Monogram® refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation.
• Do not install these products where the temperatures will
go below 55°F (13°C) or above 90°F (32°C).
• Docustom
not installpanels
where they
3/4"
for will be subject to direct
sunlight,
heat
or
moisture.
fresh food and bar refrigerator
• These products are not designed to be stacked one over
the other.
Electrical
A 120V, 60HZ., 15 or 20 amp power supply is required. An
Overlay
Panel circuit or circuit breaker
individual
properly grounded
branch
Overlay
Panel
is recommended.
Install a properly grounded 3-prong electrical
Door
receptacle
recessed into the
back
Spacer
Panelwall of the installation
opening. See cutout illustration.
Panel
The serial plate is located Backer
below
the bottom drawer liner on
1/4"
the left side.
.10 Inch
Backer
Spacer
Panel
Note: GFCI (ground fault circuit interrupter) is not recommended.
3/4" custom panels for
double - drawer refrigerator
Field-installed overlay drawer panels are required for
model ZIDI240PII.
• T he overlay panel must be secured to a 1/4"-thick backer
3/4"
panel custom
that slidespanels
into the for
drawer trim. A .10"-thick spacer
panel must
placed
the overlay and backer panel.
fresh
foodbeand
barbetween
refrigerator
3/4" custom panels for
• Custom handles of your choice must be installed onto the
double
drawer refrigerator
assembled overlay panels.
Overlay Panel
Overlay
Panel
Overlay Panel
Spacer Panel
Door Overlay
Panel
Door
1/4"
Backer
Panel
1/4"
Backer
Panel
O
Door
Spacer Panel
Backer Panel
.10 Inch
Spacer
Backer Panel
Maximum assembled panel weight is
25 lbs. (12-1/2 lbs. for each panel)
.10 Inch
Spacer
For the ultimate in convenience, install two double-drawer
refrigerators together.
• Products must
operate from separate properly
B
grounded receptacles.
A
A
12-1/2 lbs. max. B
A
1/4" Gap
12-1/2 lbs.
Note: Maintain 1/4" gap between the
drawer panels.
1/
Assemble overlay panels with glue and screws.
•C
enter spacer panel on the backer panel, left to right, and top
Route
to bottom. Secureforthe
panels with glue.
hinge
3/4
clearance
Route
for hinge
clearance
3/8
Front
28
Right
side
view
of
overlay
custom
panel
Front
•C
enter the
Topoverlay panel. Secure
3/4spacer/backer panel on the
with glue and screws. Countersink allview
screws.
Top
view
of
overlay
custom
panel
3/8
Front
3/8
7/8
Route
for hinge
clearance
Right
side
view
of
overlay
custom
panel
.
B (height)
14-11/16"
14-3/16"
15-1/16"
A (width)
1/4" backer 23-3/16"
0.10" spacer 22-1/2"
3/4" overlay 23-5/8"
B
12-1/2 lbs. max. B
1/4"
Backer
Panel
A
3/4" overlay panel dimensions (in inches)
Side -by-side installation
3/4" cust
double d
Front
of
overlay
custom
panel
3/8
7/8
Route
for hinge
clearance
12-1/2 lbs.
monogram.com
Refrigeration modules
Double - drawer
refrigerator
Fresh-food refrigerator
general features
Temperature control. Digital touch controls offer a range of
temperatures for precise chilling of a variety of fresh foods and
beverages, and an LED display allows easy viewing of
temperatures.
Flexible installation. Both the right-hand and left hand door
swing models stand beautifully on their own, or may be
built into cabinetry. Models ZIFI240PII and ZIFI240PLII accept
a custom 3/4" panel and handle for a personalized look.
Fresh-food
ZIBS240PSS Head On
refrigerator
Bar refrigerator
ZIBS240PSS
Head On
with
icemaker
Bar refrigerator with icemaker
general features
Right-hand door swing
ZIFS240PSS—Stainless steel
ZIFI240PII—Custom panel
ZIBS240PSS—Stainless steel
ZIBI240PII— Custom panel
Automatic icemaker. Self-contained icemaker features a
removable ice bin on full-extension slides and a heavy-duty
ice scoop for serving convenience.
Left-hand door swing
ZIFS240PLSS—Stainless steel
ZIFI240PLII—Custom panel
Flexible installation. The free-standing bar refrigerator stands
beautifully on its own, or may be built into cabinetry. Model
ZIBI240PII accepts custom 3/4" panel and handle for a
personalized look.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
Advance planning for fresh-food
refrigerator and bar refrigerator
with icemaker
• Built-in or free-standing
installation
• Factory-installed black
toekick, stainless toekick
included
• Trimmed model designed
to be customized with custom
panel and handle
• Right-hand or left-hand door
swing models for installation
flexibility
Overall dimensions*
(WxHxD in inches):
23-3/4 x 34-1/4 - 34-3/4" x 23-3/4
Amps @120 Volts
15
Approx. shipping wt. (lbs.)
126
• Built-in or free-standing
installation
• Factory-installed black
toekick, stainless toekick
included
• Trimmed model designed
to be customized with custom
panel and handle
• Right-hand door swing only
O u t d o o r/ i n d o o r
refrigerator
Storage convenience. Beverage shelf on full-extension slides
holds up to five wine bottles or ten 12-oz. cans, while spillproof
glass shelves provide ample space for fresh foods and beverages.
Overall dimensions*
(WxHxD in inches):
23-3/4 x 34-1/4 - 34-3/4" x 23-3/4
Amps @120 Volts
15
Approx. shipping wt. (lbs.)
126
ZIFS240PSS
W ine re se r ve, wine c hille r
b eve rage ce nte r
Temperature control. Digital touch controls allow a range of
temperature settings for different cooling needs, and an LED
display makes settings clearly visible.
ZIFS240PSS
Fr e s h - f o o d r e f r i g e r a t o r
bar refrigerator
Storage convenience. Removable, spillproof glass shelves,
along with a QuickSpace™ shelf and a clear Lexan® crisper
on full-extension slides, provide easy access to contents.
*Height excluding legs, including
hinge; depth excluding handle
The installation space
The Monogram fresh-food refrigerator and bar refrigerator
with icemaker may be installed beneath a countertop or can
be used free-standing.
• If installing between frameless cabinets, a 1/2"-wide filler
strip or side panel may be required. The filler strip will act as
a spacer between the door case and adjacent cabinet and
will prevent interference with cabinet door swing. The width
of the opening must include filler panels.
Note: When installed, the stainless steel models ZIFS240PSS and
ZIBS240PSS will be flush with adjacent cabinetry. If installing
between frameless cabinets, a 1/2" wide filler strip or side panel
may be required to prevent interference with cabinet door swing.
Models ZIFI240PII and ZIBI240PII will project forward 1-3/4" of
adjacent 24"-deep cabinets.
34-1/2"
to
35"
Locate Outlet
10-1/2"
Water and
24" Min.
Electrical 9"
Locations Max.
23-3/4" Stainless Steel
Models
1/2"
24-7/8" Framed Models
1-1/2"
23-3/4" Min.
Depth Including
Handle:
26" Stainless Steel
Models Only
34-1/4" - 34-3/4"
23-3/4"
29
Advance planning for fresh-food refrigerator
and bar refrigerator with icemaker
Location requirements
All Monogram® refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation and door swing.
• Do not install these products where the temperatures will
go below 55°F (13°C) or above 90°F (32°C).
• Do not install where they will be subject to direct
sunlight, heat or moisture.
• These products are not designed to be stacked one over
the other.
Electrical
A 120V, 60HZ., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall of the installation
location. See cutout illustration.
Note: GFCI (ground fault circuit interrupter) is not recommended.
Water line
Bar refrigerators are equipped with an automatic icemaker.
The water line can enter an opening in the back wall or floor
as shown in the cutout illustration. Route GE SmartConnect™
kit or 1/4" O.D. copper tubing between the cold water line and
the water connection location. The installation of an easily
accessible shut-off valve in the water line is required.
3/4" custom panels for fresh-food refrigerator
and bar refrigerator with icemaker
A field-installed overlay door panel is required for models
ZIFI240 and ZIBI240 refrigerators.
• The overlay panel must be secured to a 1/4"-thick backer
3/4"
custom
panels
fordoor trim. A .10"-thick spacer panel
panel
that slides
into the
mustfood
be placed
the overlay and backer panel.
fresh
and between
bar refrigerator
3/4" custom panels for
• Custom handles of your choice must be installed onto the
fresh
food and bar refrigerator
assembled overlay panel.
•Z
TBSS1 Monogram stainless steel tubular handle is available
for models ZIFI240 and ZIBI240.
Overlay Panel
Overlay
Panel
Door
Overlay
Panel
Door
1/4"
Backer
Panel
1/4"
Backer
Panel
Door
Overlay Panel
Spacer Panel
Spacer Panel
Backer Panel
.10 Inch
Spacer
Over
Pan
Backer Panel
.10 Inch
Spacer
Maximum
assembled
panel weight
is 25 lbs.
3/4" overlay panel dimensions (in inches)
1/4" backer
0.10" spacer
3/4" overlay
B
A (width)
23-3/16"
22-1/2"
23-5/8"
B (height)
29-9/16"
29-1/16"
30"
A
Make the most of your kitchen space with two Monogram
refrigeration modules installed together.
Assemble overlay panels with glue and screws.
• Products must operate from separate properly
grounded receptacles.
•C
enter spacer panel on the backer panel, left to right, and top
to bottom. Secure the panels with glue.
Door swing clearances
•C
enter the spacer/backer panel on the overlay panel. Secure
Route
with glue and screws.
for hinge Countersink all screws.
All Monogram refrigeration modules are factory set for a 110°
door swing.
When installed in a corner:
• Allow the minimum door swing clearances shown. The use of
a custom panel and custom handle influences the minimum
clearances required.
• The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
Right-hand door
swing shown.
Allow the same
clearances
for left-hand
models on the
opposite side.
A
Minimum to Wall
90° Door
Swing
110° Door
Swing
21-5/8"
A
clearance
Top
Route
view
Use a 3/4" router bitfortohinge
cut a notch into the back side of the
of
clearance
Top the notch 3/4" deep,
assembled3/4
panel3/8for hinge clearance.
Cut
overlay
view
7/8" wide and
side.
custom
Right3/8" forward of the back
Front
Front
panelof
side
3/8
overlay
view
custom
3/8
ofRight
Front
Front
panel
side
overlay
view
custom
Route
7/8
3/8
for hinge
panelof
overlay
clearance
Note:
Right-hand
custom
models
illustrated.
Route
7/8
for hingeon the
panel
Cut notches
clearance
opposite
side for
left-hand door swing.
Custom 3/4
panel hinge routing
23-5/8"
110°
90°
B
Minimum to Wall
30
Models
ZIFS240 / ZIBS240
ZIFI240 / ZIBI240
A
14"
16"
B
4"
4-1/2"
O
Door
B
Side -by-side installation
3/4" custom
double draw
3/4" cust
double d
The serial plate is located on the inside ceiling of the fresh-food
refrigerators, and on the left wall below the ice compartment of
the bar refrigerators.
1/4"
.10 I
Backer
Spa
Panel
1/4"
.
Backer
Panel
A
12-1/2 lbs. max
A
12-1/2 lbs.
12-1/2 lbs. max
1/4" G
12-1/2 lbs.
1/
monogram.com
Refrigeration modules
Double - drawer
refrigerator
Outdoor/indoor refrigerator
general features
Outdoor design. Sturdy, professional-grade stainless
steel exterior stands up to the most demanding
environmental conditions.
Temperature control. Digital touch controls help keep foods
fresh, regardless of outdoor temperatures.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
Right-hand door swing
ZDOD240PSS—Stainless steel
Left-hand door swing
ZDOD240PLSS—Stainless steel
Overall dimensions*
(WxHxD in inches):
23-3/4 x 34-1/4 - 34-3/4 x 23-3/4
Amps @120 Volts
2
Approx. shipping wt. (lbs.)
154
O u t d o o r/ i n d o o r
refrigerator
Flexible installation. Finished on all sides in stainless steel, the
Outdoor/Indoor Refrigerator allows a wide range of installation
possibilities outside and inside your home. Both the right-hand
and left-hand door swing models stand beautifully on their own
or for even more flexibility, the top panel can be removed to
allow built-in installation.
Outdoor/indoor
ZDOD240PSSHO
refrigerator
• Built-in or free-standing installation
• Vented stainless steel toekick
• Door lock and two keys
• Stainless steel top canopy is
removable for built-in installation
• Vinyl covers for built-in and freestanding installations
• Stainless Steel Magic and
polishing cloth
• Right-hand or left-hand
door swing models for
installation flexibility
W ine re se r ve, wine c hille r
b eve rage ce nte r
Door lock. Helps prevent unwanted access, ensuring the door
remains closed.
Fr e s h - f o o d r e f r i g e r a t o r
bar refrigerator
Storage convenience. Two removable glass shelves, along with
a QuickSpace™ shelf and two full-extension beverage shelves,
allow flexible storage of fresh foods, drinks and condiments.
*Height excluding legs, including
hinge; depth excluding handle
31
Advance planning for outdoor/indoor refrigerator
The installation space
Door swing clearances
The Monogram® outdoor/indoor refrigerator may be installed
beneath a countertop or can be used free-standing. The top
canopy can be removed for installation below a countertop.
All Monogram refrigeration modules are factory set for a 110°
door swing.
• If installing between frameless cabinets, a 1/2"-wide filler
strip or side panel may be required. The filler strip will act as
a spacer between the door case and adjacent cabinet and
will prevent interference with cabinet door swing. The width
of the opening must include filler panels.
Note: When installed, the door should project forward
1-1/2" of adjacent 24"-deep cabinets.
When installed in a corner:
• Allow the minimum door swing clearances shown.
• The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
A
15"
Minimum totoWall
Minimum
Wall
110° Door
Swing
90° Door
Swing
Locate Outlet
10-1/2"
34-1/2" Min.
9"
Max.
23-5/8"
24" Min.
1-1/2"
23-3/4" Min.
110°
23-3/4"
34-1/4" - 34-3/4"
(36"with top
canopy)
26-1/2"
Including
Handle
23-3/4"
Location requirements
All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for
air circulation and door swing.
• The outdoor/indoor refrigerator may be operated in an
environment where the temperatures are 45°F (7°C) to
120°F (49°C).
• Do not install where it will be subject to direct sunlight,
heat or moisture.
• These products are not designed to be stacked one over
the other.
Electrical
A 120V, 60HZ., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown. This product
must be connected to a power source with Ground Fault Circuit
Interrupter (GFCI) protection when installed in an outdoor
location. Local codes may require a separate circuit.
The serial plate is located on the inside ceiling.
32
21-5/8"
Right-hand door swing
shown. Allow the same
clearances for left-hand
models on the opposite side.
90°
B
5-1/4"
Minimum to Wall
Minimum
Wall
monogram.com
Double - drawer
refrigerator
Refrigeration modules
ZDWT240PBS
ZDWI240WII
ZDWR240PBS
ZIWI240WII
zdwc240
zdwr240
ZDWC240NBS
zdwc240
zdwr240
Fr e s h - f o o d r e f r i g e r a t o r
bar refrigerator
Wine reser ve,
wine chiller
ZDWT240PBS–Privacy glass
ZDWI240WII–Custom frame door
ZDWR240PBS–Digital controls
ZDWC240NBS–Dial controls
Wine reser ve with privacy glass general features
Wine chiller with dial control general features
Privacy glass. Innovative liquid-crystal technology allows you to
turn glass from translucent to transparent with a simple press of
a button. Opaque setting conceals ­contents from view.
Temperature control. Adjustable thermostat can maintain the
ideal temperature for aging or serving, with a temperature range
from the mid-40s to mid-60s Fahrenheit.
Wine reser ve with custom door frame
general features
Customization. A custom door and handle are required. The
custom frame surrounds the tempered, UV-resistant glass door.
O u t d o o r/ i n d o o r
refrigerator
*Height excluding legs, including
hinge; depth excluding handle
• Built-in or free-standing
installation
• Factory-installed black
toekick, stainless toekick
included
• Unfinished cherry wood shelf
fronts can be customized
Storage convenience. Full-extension sliding racks store up to 57
wine bottles and keep them close at hand.
Flexible installation. The free-standing wine chiller may be built
into cabinetry.
W ine re se r ve, wine c hille r
b eve rage ce nte r
Overall dimensions*
(WxHxD in inches):
23-3/4 x 34-1/4 - 34-3/4 x 23-3/4
Amps @120 Volts
15
Approx. shipping wt. (lbs.)
172
Wine reser ve with digital controls
general features
Temperature control. Digital touch controls allow you to select
precise temperature settings, which are essential for proper
wine storage.
Storage convenience. Full-extension sliding racks store up to
57 wine bottles and keep them close at hand.
Flexible installation. The free-standing wine reserve may be
built into cabinetry.
33
Refrigeration modules
ZDBT240PBS
ZDBI240WII
zdbc240
ZDBR240PBS
zdbr240
ZIBI240WII
ZDBC240NBS
zdbc240
zdbr240
Beverage centers
ZDBT240PBS–Privacy glass
ZDBI240WII–Custom frame door
ZDBR240PBS–Digital controls
ZDBC240NBS–Dial controls
Overall Dimensions*
(WxHxD in inches):
23-3/4 x 34-1/4 - 34-3/4 x 23-3/4
Amps @120 Volts
15
Approx. shipping wt. (lbs.)
146
*Height excluding legs, including
hinge; depth excluding handle
• Built-in or free-standing
installation
• Factory-installed black
toekick, stainless toekick
included
• Unfinished cherry wood shelf
fronts can be customized
Beverage center with privacy glass
general features
Beverage center with dial control
general features
Privacy glass. Innovative liquid-crystal technology allows you to
turn glass from translucent to transparent with a simple press of
a button. Opaque setting conceals ­contents from view.
Temperature control. A range of temperature settings allows
you to maintain the ideal climate for your beverages of choice.
Wine reser ve with custom door frame
general features
Customization. A custom door and handle are required. The
custom frame surrounds the tempered, UV-resistant glass door.
Beverage center with digital controls
general features
Temperature control. Digital touch controls provide precise
temperature settings for cooling of all types of beverages.
Storage convenience. Three removable glass shelves, including
a QuickSpace™ shelf, and two full-extension wine racks hold up
to 10 wine bottles, as well as 12-oz. cans, quart-size bottles, and
two-liter plastic containers.
Flexible installation. The free-standing beverage center may be
built into cabinetry.
34
Storage convenience. Three removable, spillproof glass shelves
and two full-extension wine racks hold up to 12 wine bottles,
as well as 12-oz. cans, quart-size bottles and two-liter plastic
containers.
Flexible installation. The free-standing beverage center may be
built into cabinetry.
monogram.com
The installation space
Reversible door swing
The Monogram wine reserve and beverage centers may be
installed beneath a countertop or can be used free-standing.
Models ZDWI240WII, ZDWC240NBS, ZDWR240PBS, ZDBI240WII,
ZDBC240NBS and ZDBR240PBS are shipped for a right-hand door
swing. The door swing may be reversed, with no kits required.
• If installing between frameless cabinets, a 1/2"-wide filler
strip or side panel may be required. The filler strip will act as
a spacer between the door case and adjacent cabinet and
will prevent interference with cabinet door swing. The width
of the opening must include filler panels.
Note: When installed, the door should project forward 1" of
adjacent 24"-deep cabinets. Custom framed models will project
forward 1-3/4" of adjacent cabinets.
Locate Outlet
10-1/2"
24-1/8" Framed models
23-3/4" Stainless steel
models
34-1/4"34-3/4"
25-1/2"
Including
Handle
Door swing clearances
All Monogram refrigeration modules are factory set for a
110° door swing.
When Installed in a corner:
• Allow the minimum door swing clearances shown.
24" Min.
1-1/2"
23-3/4" Min.
ZTBSS1 Monogram stainless steel tubular handle is available for
models ZDWI240WII and ZDBI240WII.
23-3/4"
Location requirements
All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation and door swing.
• Do not install these products where the temperatures will
go below 55°F (13°C) or above 90°F (32°C).
• The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
A
10"
Minimum to
Minimum
toWall
Wall
90° Door
Swing
110° Door
Swing
21-5/8"
O u t d o o r/ i n d o o r
refrigerator
9"
Max.
Z TBSS1 Tubular handle
23-5/8"
*
110°
90°
*95° door swing on custom
frame models.
B
4"
Minimum to
Minimum
to Wall
wall
Custom frame panel
Models ZDWI240WII, ZDBI240WII require a custom panel frame
surrounding the glass. There are two options, the panel may be
29-3/4" or 30". A 30" panel requires a notch cut into the bottom
of the panel to avoid interference with the hinge.
• Do not install where they will be subject to direct
sunlight, heat or moisture.
Note: A solid panel that covers the door glass CANNOT be
installed on these models.
• These products are not designed to be stacked one over
the other.
Option 1
Electrical
A 120V, 60HZ., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown. Electrical
must be located on rear wall as shown.
Note: GFCI (ground fault circuit interrupter) is not recommended.
The serial plate is located on the inside ceiling.
Option 2
23-1/8”
23-1/8”
2-1/4”
wide,
all sides
Rout the
back side
of the
opening
7/16”deep,
1-1/8” wide
2-1/4”
25-1/4”
GLASS
29-3/4”
25-1/4”
Route the back
side of the
opening 7/16”
deep, 1-1/8” wide
GLASS
30”
18-5/8”
18-5/8”
2-1/2” at
bottom
3/4” Thick Custom Panel,
Back Side
2-1/4”
1/8”
1/4”
2-1/4”
Cut the notch
1/8” deep, 1/4”
wide and 1/4”
high
For a complete refreshment center, install a Monogram wine
reserve and beverage center together.
Note: Right-hand models
illustrated. Cut notches on the
opposite side for left-hand
door swing.
• Products must operate from separate properly
grounded receptacles.
Choose Option 1 or Option 2 panel size depending on cabinetry
size or style.
Side -by-side installation
W ine re se r ve, wine c hille r
b eve rage ce nte r
34-1/2"-35"
Privacy glass wine reserves and beverage centers have a
right-hand door swing. They cannot be reversed.
Fr e s h - f o o d r e f r i g e r a t o r
bar refrigerator
®
Double - drawer
refrigerator
Advance planning for wine reserves and beverage centers
1/4”
35
Automatic icemaker
General features
High production, large capacity. The icemaker produces up to
50 pounds of clear ice per day and automatically shuts off when
the 25-pound-capacity bin is full.
Customization. The 15" icemaker door accepts a 3/4" custom
panel to match surrounding cabinetry. You can also add your
own custom handle.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
Automatic
icemaker
ZDIS150WSS
ZDIS150WSS, ZDIC150WBB, ZDIC150WWW
Overall dimensions
(WxHxD in inches):
14-13/16 x 34-1/2 x 23-5/16
Amps @ 115 Volts
5.3
Approx. shipping wt. (lbs.)
110
• Built-in or free-standing installation
• Accepts 3/4" custom panels, requires kit
• Reversible door swing, no kit required
• Leveling system
Advance planning for automatic icemaker
The installation space
The Monogram® icemaker may be installed
free-standing or below a countertop.
34" to
34-1/2"
24"
Min.
Water and Electrical
Supply Should Enter
From Back Wall In
Shaded Area.
3"
11-1/2"
9"
*15"
* 16-1/2" with a 3/4"
thick custom panel
Note: The addition of
a 3/4"-thick custom
panel will result in a
front-to-back depth
of 24-1/16". The
icemaker cannot
be installed flush to
adjacent 24" deep
cabinets with a 3/4"thick custom panel.
36
28-1/2"
The installation of a 3/4” thick
custom panel will require an
additional 1-1/2” wide filler
strip on the hinge side.
34" min.
Adjustable
to 34-1/2"
23-5/16" to
Door Front
14-13/16"
The serial plate is located
on the left wall of the ice
storage bin.
Note: The installation of a 3/4"-thick custom panel will require
an additional 1-1/2"-wide filler strip on the hinge side. The
filler strip will act as a spacer between the icemaker case and
adjacent cabinet. The filler strip will prevent interference with
the icemaker door swing when it is installed between frameless
or framed cabinetry. The width of the opening must include the
filler strip.
The icemaker may be closed in on the top and sides as long as
the front is unobstructed for air circulation and proper access to
the door.
• Do not install these products where the temperatures will go
below 55° (13°C) or above 110° (32°C).
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown.
Water line
The water line can enter the opening through the back wall
as shown. Route GE SmartConnect™ kit or 1/4" O.D. copper
tubing between the cold water line and the water connection
location at the rear of the icemaker. The installation of an easily
accessible shut-off valve in the water line is required.
monogram.com
Custom panel kits
Door swing clearances
Order ZIP75WW, white or ZIP75BB, black, 3/4" trimless custom
panel kit.
• Order the panel so that
approximately 1/2" of the back
side edge is finished. The back
3/4"
Thick
29-1/2"
edge of the panel will be visible
Custom
and therefore should be finished.
Panel
• Custom handles may be used
with this kit.
• A side filler panel may be
14-23/32"
required on the hinge side to
ensure a full door swing.
The icemaker is factory set for a right-hinge door swing with
the door swinging from left to right. The door swing may be
reversed to a left-hinge swing. No kits required.
• The installation must allow for clearances to adjacent walls
or cabinets. The icemaker is factory set for a 110° door swing.
110° door swing
90° door swing
WALL
21-1/2"
Z TBSS1 Tubular handle
605Dia52
Monogram stainless steel tubular handle can be installed on
the 3/4"-thick custom panel.
15-1/2"
90°
110°
Drainage requirements
5-1/2" Minimum
to Wall
A method of drainage must be determined in advance.
3-1/2"
High
A u t o m a t i c i c e m a ke r s
Advance planning for automatic icemaker
2" Minimum
to Wall
• Allow 5-1/2" minimum clearance on the hinge side for a full
110° door swing.
605Dia54
• 2" minimum clearance is required for access to the ice bin
when the door swing is restricted to 90°.
605Dia53
Side
View
7-1/2"
15"
Locate Standpipe in exact
Center of The Cutout
Drain
Hose
1" Min. Gap
3-1/2"
605Dia51
22"
22-3/4" With 3/4"
Custom Panel
• The ideal installation has a standpipe with a 2" to 1-1/2" PVC
drain reducer installed directly below the outlet of the drain
tube. The standpipe must be accurately located to prevent
interference when sliding the icemaker into the opening.
Maintain 1" gap between standpipe and icemaker drain hose.
• The installation of a 3/4" custom door panel will influence the
floor drain location.
• When a floor drain is not located below the icemaker, order
ZPK1 drain pump kit. This pump must be installed inside the
unit and can pump to a maximum vertical height of 10 feet.
The 10-ft. tubing is supplied with the kit.
• The drain lines must be at least 5/8" inside diameter.
605Dia50
37
Compactors
15" compactor general features
Fifteen-inch width. Fully integrated design with hidden controls,
installs flush with surrounding cabinetry.
Powerful pressure. Large 1.4 cu. ft. capacity. Reduces trash volume
by 75 percent.
Safe operation. A removable knob prevents unwanted use.
The compactor foot pedal is used to both open the drawer
and initiate operation, making it easy to use and convenient.
Customization. For stainless steel model, order ZCGS150LSS.
Model ZCGP150LII requires a 3/4" overlay panel and a custom
handle. Shipped with both stainless steel and black toekicks.
12 " compactor general features
Twelve-inch width. The slim design conserves space and
permits attractive integration into cabinetry.
Powerful pressure. Large 1.4 cu. ft. capacity. Reduces trash
volume by 75 percent, allowing easy transport and disposal.
Safe operation. A removable key locks the compactor,
starts operation, and assures that the drawer remains locked
during use.
Customization. For stainless steel model, order ZCG3500DSS.
White (ZCG3300VWW) and black (ZCG3100VBB) models also
accept a 1/4" or 3/4" overlay panel and a custom handle.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
38
ZCGS150LSS
15" compactors
12" compactors
ZCGS150LSS—Stainless steel
ZCGP150LII—Custom panel
ZCG3500DSS, ZCG3100VBB and
ZCG3300VWW
Overall dimensions
(WxHxD in inches):
14-7/8 x 33-3/4 to 35 x 23
Amps @ 120 Volts
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
12 x 34 – 35 x 20-1/4
Amps @ 120 Volts
Approx. shipping wt. (lbs.)
• Large 1.4 cu. ft. capacity
• Built-in installation only
• Foot pedal open and start
5.0
141
• Large 1.4 cu. ft. capacity
• Built-in installation only
• No trim kits required for
customization
5.0
135
monogram.com
Advance planning for 15" compactors
• The compactor is designed for built-in applications only.
It cannot be operated free-standing.
24"
min.
Compactors
This 15" wide Monogram® compactor offers a large
1.4-cu.- ft. capacity.
34" - 35"
15-1/8"
min.
Custom panel dimensions
Install a 3/4" thick custom drawer panel and custom panel of
your choice onto the ZCGP150LII. For planning purposes, you
may order the template, Pub. No. 31-30597 in advance.
The maximum panel weight is 12 lbs.
3/4"
Thick
Custom
Panel
33-3/4"
min. to
35" max.
Locate the outlet 18" min.
from the floor, 3" min.
from either side.
24” case/
Clearances: Allow 6"
door depth
clearance to a vertical
26” including
wall on the right side
handle
for bag removal.
Allow 23" at the front
for a full drawer opening.
29-5/16"
14-7/8
14-7/8"
Advance planning for 12" compactors
For an extra touch of convenience, Monogram built-in
compactor fits in a neat 12" space.
• This compactor is designed for built-in applications only.
It cannot be used free-standing.
• This compactor has an adjustable base which allows the toekick
depth to be set to match adjacent cabinetry.
12-1/8"
min.
34"-35"
Note: Locate the
outlet 18" min. from
the floor, 3" min.
from either side.
Custom panel dimensions
T he drawer trim on black and white models accepts
1/4" and 3/4" custom panels. No trim kits required. When a
3/4"-thick panel is used, the handle may be replaced with a
custom handle of your choice.
The drawer panel size varies depending on application.
24-1/2"
1/4" Custom
Drawer
Panel
24-3/4"
3/4" Custom
Drawer
Panel
25-13/16"
3/4" Custom
Drawer
Panel With
Custom
Handles
20-1/4"
12"
11-11/16"
34"
min.
adj. to
35"
max.
22-1/2" min.*
*Add 2-1/2" to
depth if outlet
is located directly
behind compactor
12"
1/4"-thick custom panel
Cut the panel to size and install.
3/4"-thick custom panel
The custom panel should be constructed in the same manner
as typical cabinet doors. Cut edges must be finished on all sides.
The supplied handle may be replaced with a custom handle of
your choice.
605Dia179
12"
Adjustable base
2-3/4" to 4-1/4"
605Dia178
39
Dishwashers
OFF
HEAVY WASH
NORMAL WASH
LIGHT WASH
CHINA CRYSTAL
RINSE ONLY
Fully integrated
dishwasher
Fully integrated
dishwasher
ZBD0710KSS
ZBD6890KII.eps
ZBD0710NSS
Overall dimensions
(WxHxD in inches):
24 x 34–35 x 24
Amps @120 Volts
Approx. shipping wt. (lbs.)
• Accepts custom toekick
• Exterior end-of-cycle
indicator light
ZBD0700NII and ZBD6890NII
9.1
122
Fully integrated
dishwasher
Compact dishwasher
ZBD6880
ZBD6880NSS, ZBD6800NWW
and ZBD6800NBB
ZBD1800GSS
Overall dimensions
(WxHxD in inches):
24 x 34–35 x 24*
Amps @120 Volts
9.1
Approx. shipping wt. (lbs.) 117/115
Overall dimensions
(WxHxD in inches):
24 x 34–35 x 24
Amps @120 Volts
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
17-1/2 x 32-1/2–35 x 22-1/2
Amps @120 Volts 12.0
Approx. shipping wt. (lbs.)
60
• A custom panel and handle
are required
• Accepts custom toekick
• Accepts professional-style
door/panel handle kit,
ZPRO0700S
• Accepts ZTB700 stainless steel
tubular handle
• Accepts custom toekick
ZBD1800GSS.eps
9.1
120
• ADA-compliant installation
below 34"-high countertops
• Compact design
• Two-piece adjustable toekick
* 24-3/4" with custom panel
(not including handle)
General fully integrated dishwasher features
Seamless style. The fully integrated design with concealed,
top-mounted controls installs flush** with surrounding
cabinetry for a dramatic, yet understated, effect.
Ultraquiet operation. A quiet-engineered motor, extra-thick
insulation and special sound-absorbing materials virtually
eliminate the sound of washing dishes.
Brilliant interior lighting. Used in headlights of highperformance automobiles, xenon technology provides
superior light quality and brightness. (ZBD0710NSS and
ZBD0700NII only)
End-of-cycle indicator. Discreet lighting on the outside of
the dishwasher lets you know when the cycle is complete
and your dishes are clean and dry. (ZBD0710NSS only)
Powerful, forced-air drying system. A fan-assisted, vented
drying system extracts moist, warm air. Dishes come out dry,
ready for the table or shelf.
Complete cleaning coverage. Three direct-feed wash arms
and six wash levels assure that every dish and utensil is
sparkling clean. A three-stage filter system helps prevent
food soils from being redeposited on dishes.
40
Extra-tall tub with towerless rack system. The generously
sized interior provides the space and loading flexibility
necessary to accommodate 16 place settings, with no wash
tower to get in the way. The upper rack moves up, down and
diagonally in one-inch increments, allowing maximal use of
space above and below the rack.
General compact dishwasher features (ZBD1800GSS)
ADA-compliant. The compact configuration can be installed
at a height that allows easy access.
Easy-to-use controls. The mechanical dial turns easily to the
desired wash cycle: heavy wash, normal wash, light wash,
china, crystal or rinse only.
Dual-motor, dual-wash-arm system. Two motors and wash
arms provide effective, yet quiet, cleaning power.
Nylon-coated racks. Durable racks provide plenty of space
and loading flexibility. Lower rack includes a stem-safe shelf
for odd-shaped items and delicate stemware.
**Flush at 24" for black, white and stainless models; flush
at 24-3/4" for custom panel models.
monogram.com
Advance planning for dishwashers
dis h wa s h er s
The installation space
Monogram® dishwashers are designed for versatility,
adaptable to virtually any installation.
The rough cabinet opening must be prepared to the
dimensions shown.
• These dishwashers may be installed beneath
countertops of stone or other materials that will
not accept screws.
• The dishwasher must be installed so that the drain hose is no
more than 10 feet in length for proper drainage.
Supplied or custom toekick
• A two-piece toekick is supplied with model ZBD1800GSS.
The toekick is height-adjustable.
• Depending on cabinetry style, a custom toekick can also
be installed to match cabinetry. Care must be taken to assure
door swing clearance above the toekick.
• Water and power supply should enter in the shaded area.
• Electrical and water connections are at the right front of the
dishwasher. The hot water line should extend forward 30" to
40" from the rear wall. The electrical must extend forward at
least 24" to reach the junction box.
• To prevent siphoning, an air gap must be used when the waste
tee or disposer connection is less than 18" above the floor.
ADA-compliant ZBD1800GSS:
Installation below 34"-high countertops
A reduced-height installation (32-1/2" min.) beneath a 34"
countertop can be accomplished by adjusting the leveling legs
and toekick.
Electrical requirements
Monogram 18" dishwashers
cutout dimensions and clearances
Monogram 24" dishwashers
cutout dimensions and clearances
34" to 35"
Underside of
Countertop
to Floor
17-5/8" Min.
18" Max.
Floor MUST
be Even with
Room Floor.
24"
Min.
The dishwasher must be supplied with 120V, 60Hz, and
connected to an individual properly grounded branch circuit
protected by a 15- or 20-amp circuit breaker or time-delay fuse.
34-1/2" Min.
Underside of
Countertop
to Floor
Cabinets
Square
and
Plumb
This Wall Area
must be Free of
Pipes or wires
5"
4"
24"
5" 4" Min.
Cabinets
Square
and
Plumb
6"
24" Min.
32-1/2"
Adjustable
to 35"
22-1/2" Max.
17-1/2"
34"
Adjustable
to 35"
Floor MUST
be Even with
Room Floor
*Dishwasher models ZBD6890
and ZBD0700 require a 3/4" thick
custom panel and will be 24-3/4"
deep. (not including handle)
*24"
24"
ZBD0700Nll and ZBD6890Nll
Fully integrated models with hidden controls.
Require a 3/4" thick custom panel and a custom handle.
ZBD0710NSS, ZBD6800NBB, ZBD6800NWW, ZBD6880NSS
dishwashers. These models have a fully wrapped black, white
or stainless steel door.
41
Advance planning for dishwashers
Custom panels
Custom accessories
Custom panel for fully integrated models
ZBD0700NII and ZBD6890NII
These models require a field-installed 3/4" thick custom panel
and custom handle. An installation template is packed with
these models and may be obtained in advance. Order Pub.
No. 31-30569-1. Complete panel installation instructions are
included on the template.
ZTB700 tubular handle
Install this Monogram® stainless steel tubular handle onto
your 3/4"-thick custom door panel. The handle is 22-1/2" wide
and 1-1/8" deep. For models ZBD6890NII and ZBD0700NII only.
Custom panel size requirements
ZPRO0700S professional style door panel
This panel provides a professional style handle on a stainless
steel door panel. Transform the ZBD6890NII or the ZBD0700NII
to complement a commercial-style kitchen.
Standard flush installation
• Models ZBD0700 and ZBD6890 dishwashers have a total
depth of 24-3/4," including the required 3/4" thick door panel.
They will install flush with cabinets that are 24-3/4" deep
(including typical 3/4" thick cabinet doors).
30-1/16" Min.
30-1/4" Max.
NOTE:
Maximum door
panel weight is
14 lbs.
23-3/4"
HEIGHT:
Panel height must be between 30-1/16" and 30-1/4"
• If the panel height is more than 30-1/4", it will prevent the door from swinging open.
• If the panel height is less than 30-1/16", it will not cover
the dishwasher door frame.
• The top of the custom panel must be flush with the
top of the door. A 1/2" minimum gap between the top
of the door and the bottom of the countertop must
be maintained.
WIDTH:
Panel width must be 23-3/4"
• If the panel width is less than 23-3/4", it will not cover
the dishwasher frame.
Heavy-duty springs
Heavy-duty door springs are provided with the product.
The springs must be installed to support the weight of a
custom door panel or when installing the professional-style
stainless steel door panel, ZPRO0700S.
If needed, replacement door springs can be ordered.
Order part number WD03X10023.
42
• Black, white and stainless steel dishwashers will install flush
with 24" deep surrounding cabinetry.
monogram.com
General features
Professional styling. Oversized range makes a bold culinary
OFF
BAKE
CONV
BROIL
CLEAN
OVEN
statement in lustrous, professional-grade stainless steel.
48" p rof e s s ion al ran ges
48" dual-fuel professional ranges
OVEN
LIGHT
GRILL
OFF
BAKE
BROIL
PROOF
DOOR LOCKED
HEATING
OVEN
OVEN
LIGHT
HEATING
Sealed, dual-flame stacked burners. Two separate flames on
each burner give you a range of precise temperatures, from a low
140°F simmer to a powerful 17,000-BTU* setting. The burners are
sealed to the recessed cooktop subsurface for easy cleaning.
Unique reversible grates. The individual burner grates
one side and rounded on the other for grilling versatility. A
Gourmet Radiant™ tray ensures even heat distribution, while
reducing flare-ups.
18,000-BTU* griddle. The 3/8"-thick, stainless steel griddle
is also sloped to offer a clean cooking surface. Thermostatic
control ensures even heating and consistent results.
Main oven (4.6 cu. ft., 27" wide)/
Companion oven (2.1 cu. ft., 12" wide). The large,
self-cleaning convection oven offers two multipass broil and
bake elements for even browning and baking. The companion
oven is equipped with a single 6-pass broil element and 4-pass
bake element.
Self-clean oven racks. Heavy-duty, porcelain-coated racks are
designed to remain in the main oven during the oven self-clean
cycle for effortless cleaning.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
*15,000 BTU on liquid propane models.
36" professional ra n g e s
18,000-BTU* grill. The stainless steel surface is grooved on
48" professional
range
ZDP48N4GHSS
ZDP48N4GHSS, ZDP48N6RHSS and
ZDP48N6DHSS (natural gas)
ZDP48L4GHSS, ZDP48L6RHSS and
ZDP48L6DHSS (liquid propane)
Overall dimensions
(WxHxD in inches):
47-7/8 x 35-1/4– 36 -3/4 x 28-1/4
Amps @240VAC
41.0
208VAC
34.6
KW Rating
@240VAC
9.8
208VAC
7.2
Approx. shipping wt. (lbs.)
640
30" professional ranges
are flat on one side and uniquely contoured on the other to
accommodate various size works. When positioned flat, the
grates create a continuous cooking surface.
• Dual-fuel range offers a
combination of burners, grill
and griddle on cooktop
• Natural or LP gas must be
specified by model number
• Optional 12" or 22" backsplash
accessories
• All burner grates are reversible
to support a round-bottom wok
Advance planning for 48" professional ranges
Professional ranges offer a number of choices in size and
cooktop configurations.
• All professional ranges are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.
Note: Conversion kits (WB49X10132, Natural to LP and
WB49X10133, LP to Natural) are available if the wrong fuel type
was ordered. High altitude kit, WB49X10130 (for Natural and
LP gas models), is also available. This kit includes orifices for
operation at 3,000 to 6,000 feet and another set for operation
at 6,000 or more feet. Conversion kits must be installed by a
qualified service technician at additional cost.
Locate gas
and electrical
as shown.
12"
Gas
Supply
Ranges must be supplied with 208/240V, 60Hz, and connected
to an individual, properly grounded branch circuit protected by a
circuit breaker or time-delay fuse. Install a 50-amp circuit for 48"
ranges. The receptacle must be a NEMA 14-50R device to accept
the four-prong plug on the range.
Gas supply
• Natural gas models are designed to operate at 5" water column
pressure. A regulator is required at the natural gas source to
provide maximum of 7" water pressure to the range regulator.
• The liquid propane models are designed to operate at 10" water
column pressure. A regulator is required at the LP source to
provide maximum of 14" water pressure to the range regulator.
8"
4"
8"
4"
Electrical requirements
16"
48"
Electric
Supply
1-1/2"
43
Advance planning for 48" dual-fuel professional ranges
48" range cooktop configurations
Backsplash accessories
The 48" professional dual-fuel ranges are available with a
combination of grill, griddle and burners on top, a large electric
convection oven and companion thermal oven.
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
ZDP48N4GHSS
with 4 burners, grill
and griddle
(Order ZDP48L4GHSS
for LP gas)
ZX12B48HSS, 12" backsplash
ZX22B48HSS, 22" backsplash with warming shelf
Backsplash with warming shelf
All Monogram® professional wall mount hoods feature
infrared warming lights. The 22"-high backsplash accessory
with warming shelf is a perfect complement when installed
with the tapered or straight-sided hoods. Restaurant-style
professional hoods are shipped with a stainless steel
backsplash and warming shelf.
ZDP48N6RHSS
with 6 burners and grill
(Order ZDP48L6RHSS
for LP gas)
Side view with a backsplash
12" Min. to Combustibles or
0" Min. to Combustibles
with 12" or 22" Backsplash
36" Min.
to
Combustibles
ZDP48N6DHSS
with 6 burners and griddle
(Order ZDP48L6DHSS
for LP gas)
Backguard
0" Clearance
Product dimensions and clearances
A 54"- or 48"-wide professional vent hood with a minimum
1200 CFM is recommended for installation over this range.
Optional
h
Backsplas
The serial plate is located beneath the ledge trim,
just above the left knob.
22"
12"
1-1/2"
Note: depth
including handle
is 31-1/2".
35-1/4"
to
36-3/4"
28-1/4"
47-7/8"
Clearances between range and side wall or combustible
material must be at least 12" on each side.
44
monogram.com
General features
Professional styling. Combining style and quality in
OFF
BAKE
CONV
BROIL
48" p rof e s s ion al ran ges
36" dual-fuel professional ranges
CLEAN
OVEN
LIGHT
perfect measure, these ranges offer the impressive look and
high-performance cooking capabilities of commercial appliances.
DOOR LOCKED
HEATING
Sealed, dual-flame stacked burners. Each gas burner
cooking with posts and pans, while the other side is uniquely
contoured to allow stir-frying with a wok.
18,000-BTU* grill. The stainless steel grill grate is reversible, with
a grooved surface for marinated foods and a rounded side for
grilling of delicate foods. A Gourmet Radiant™ tray ensures even
heat distribution, while reducing flare-ups from dripping juices.
18,000-BTU* griddle. The 3/8"-thick, stainless steel griddle is
sloped to offer a clean cooking surface. Thermostatic control
ensures even heating and cooking results.
Self-clean oven racks. Heavy-duty, porcelain-coated oven
racks are designed to remain in the oven during the oven
self-clean cycle for effortless cleaning.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
*15,000 BTU on liquid propane models.
36" professional
ZDP36N4DHSS range
36" professional ra n g e s
Unique reversible grates. One side offers a flat surface for
ZDP36N4DHSS, ZDP36N4RHSS and
ZDP36N6HSS (natural gas)
ZDP36L4DHSS, ZDP36L4RHSS and
ZDP36L6HSS (liquid propane)
Overall dimensions
(WxHxD in inches):
35-7/8 x 35-1/4– 36 -3/4 x 28-1/4
Amps @240VAC
22.2
208VAC
18.7
KW Rating
@240VAC
5.3
208VAC
3.9
Approx. shipping wt. (lbs.)
450
30" professional ranges
uses two separate flames to give you a range of precise
temperature options, from an ultra low 140°F simmer to a
powerful 17,000-BTU* setting. The burners are sealed to the
recessed cooktop subsurface for easy cleaning.
• Dual-fuel range offers a
combination of burners, grill
and griddle on cooktop
• Natural or LP gas must be
specified by model number
• Optional 12" or 22" backsplash
accessories
• All burner grates are reversible
to support a round-bottom wok
Advance planning for 36" professional ranges
All professional ranges offer a number of choices in size and
cooktop configurations.
• All professional ranges are factory set for natural or
liquid propane gas. The correct model should be
ordered for the installation situation.
Note: Conversion kits (WB49X10132, Natural to LP and
WB49X10133, LP to Natural) are available if the wrong fuel type
was ordered. High altitude kit, WB49X10130 (for Natural and
LP gas models), is also available. This kit includes orifices for
operation at 3,000 to 6,000 feet and another set for operation
at 6,000 or more feet. Conversion kits must be installed by a
qualified service technician at additional cost.
Locate gas
and electrical
as shown.
4"
4"
12"
Gas
Supply
Electrical requirements
Ranges must be supplied with 208/240V, 60Hz, and connected
to an individual, properly grounded branch circuit protected by a
circuit breaker or time-delay fuse. Install a 30-amp circuit for 36"
ranges. The receptacle must be a NEMA 14-50R device to accept
the four-prong plug on the range.
Gas supply
• Natural gas models are designed to operate at 5" water column
pressure. A regulator is required at the natural gas source to
provide maximum of 7" water pressure to the range regulator.
• The liquid propane models are designed to operate at 10" water
column pressure. A regulator is required at the LP source to
provide maximum of 14" water pressure to the range regulator.
4"
4"
12"
36"
Electric
Supply
1-1/2"
45
Advance planning for 36" dual-fuel professional ranges
36" range cooktop configurations
Backsplash accessories
The 36" professional dual-fuel ranges offer a combination of
grill, griddle and burners on top, and a large self-clean, electric
convection oven.
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required for
installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
ZDP36N4DHSS
with 4 burners and griddle
(Order ZDP36L4DHSS for LP gas)
ZX12B36HSS, 12" backsplash
ZX22B36HSS, 22" backsplash with warming shelf
Backsplash with warming shelf
All Monogram® professional wall mount hoods feature
infrared warming lights. The 22"-high backsplash accessory
with warming shelf is a perfect complement when installed
with the tapered or straight-sided hoods. Restaurant-style
professional hoods are shipped with a stainless steel
backsplash and warming shelf.
ZDP36N4RHSS
with 4 burners and grill
(Order ZDP36L4RHSS for LP gas)
Side view with a backsplash
12" Min. to Combustibles or
0" Min. to Combustibles
with 12" or 22" Backsplash
36" Min.
to
Combustibles
ZDP36N6HSS
with 6 burners
(Order ZDP36L6HSS for LP gas)
Backguard
0" Clearance
Product dimensions and clearances
A 42"- or 36"-wide professional vent hood with a
minimum 600 CFM is recommended for installation
over this range.
Optional
h
Backsplas
12"
1-1/2"
Note: depth
including handle
is 31-1/2".
35-1/4"
to
36-3/4"
28-1/4"
The serial plate is located beneath the ledge trim, just
above the left knob.
22"
35-7/8"
Clearances between range and side wall or combustible
material must be at least 12" on each side.
46
monogram.com
General features
Professional styling. Combining style and quality in
OFF
BAKE
CONV
BROIL
48" p rof e s s ion al ran ges
30" dual-fuel professional ranges
CLEAN
OVEN
LIGHT
perfect measure, these ranges offer the impressive look and
high-performance cooking capabilities of commercial appliances.
DOOR LOCKED
HEATING
Sealed, dual-flame stacked burners. Each gas burner
cooking with pots and pans, while the other side is uniquely
contoured to allow stir-frying with a wok.
Self-clean oven racks. Heavy-duty, porcelain-coated oven
racks are designed to remain in the oven during the oven
self-clean cycle for effortless cleaning.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
*15,000 BTU on liquid propane models.
30" professional range
ZDP30N4HSS
36" professional ra n g e s
Unique reversible grates. One side offers a flat surface for
ZDP30N4HSS (natural gas)
ZDP30L4HSS (liquid propane)
Overall dimensions
(WxHxD in inches):
29-7/8 x 35-1/4– 36 -3/4 x 26-3/4
Amps @240VAC
18.7
208VAC
16.2
KW Rating
@240VAC
4.5
208VAC
3.4
Approx. shipping wt. (lbs.)
420
30" professional ranges
uses two separate flames to give you a range of precise
temperature options, from an ultralow 140°F simmer to a
powerful 17,000-BTU* setting. The burners are sealed to the
recessed cooktop subsurface for easy cleaning.
• Dual-fuel range offers a gas
cooktop and an electric oven
• Natural or LP gas must be
specified by model number
• Optional 9" or 22"
backsplash accessories
• All burner grates are reversible
to support a round-bottom wok
Advance planning for 30" professional ranges
All professional ranges are factory set for natural or
liquid propane gas. The correct model should be ordered for
the installation situation.
Note: Conversion kits (WB49X10132, Natural to LP and
WB49X10133, LP to Natural) are available if the wrong fuel type
was ordered. High altitude kit, WB49X10130 (for Natural and
LP gas models), is also available. This kit includes orifices for
operation at 3,000 to 6,000 feet and another set for operation
at 6,000 or more feet. Conversion kits must be installed by a
qualified service technician at additional cost.
Locate gas
and electrical as
shown.
4"
4"
12"
2"
Gas
Supply
30"
4"
8"
Electric
Supply
1-1/2"
Electrical requirements
Ranges must be supplied with 208/240V, 60Hz, and connected
to an individual, properly grounded branch circuit protected by a
circuit breaker or time-delay fuse. Install a 25-amp circuit for 30"
ranges. The receptacle must be a NEMA 14-50R device to accept
the four-prong plug on the range.
Gas supply
• Natural gas models are designed to operate at 5" water column
pressure. A regulator is required at the natural gas source to
provide maximum of 7" water pressure to the range regulator.
• The liquid propane models are designed to operate at 10" water
column pressure. A regulator is required at the LP source to
provide maximum of 14" water pressure to the range regulator.
47
Advance planning for 30" dual-fuel professional ranges
Product dimensions and clearances
Backsplash accessories
A 36"- or 30"-wide professional vent hood with a minimum
600 CFM is recommended for installation over this range.
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
• Install the hood 30" to 36" above the cooking surface.
Optional
h
Backsplas
ZX9B30HSS, 9" backsplash
ZX22B30HSS, 22" backsplash with warming shelf
22"
9"
Backsplash with warming shelf
1-1/2"
Note: depth
including handle
is 29-3/4".
35-1/4"
to
36-3/4"
26-3/4"
29-7/8"
Clearances between range and side wall or combustible
material must be at least 12" on each side.
All Monogram® professional wall mount hoods feature
infrared warming lights. The 22"-high backsplash accessory
with warming shelf is a perfect complement when installed
with the tapered or straight-sided hoods. Restaurant-style
professional hoods are shipped with a stainless steel
backsplash and warming shelf.
Side view with a backsplash
12" Min. to Combustibles or
0" Min. to Combustibles
with 9" or 22" Backsplash
36" Min.
to
Combustibles
Backguard
0" Clearance
The serial plate is located beneath the ledge trim, just
above the left knob.
48
monogram.com
Prof e s s ion a l g a s cookt ops
Gas cooktops
48" professional gas cooktop general features
Professional styling. Professional-grade stainless steel
with cast-iron grates makes a striking design statement in
any kitchen.
Unique reversible grates. One side offers a flat surface for
cooking with pots and pans, while the other side is uniquely
contoured to allow stir-frying with a wok.
18,000-BTU* grill. The stainless steel grate is reversible, with
a grooved surface for marinated foods and a rounded side for
searing of meats and fish. A Gourmet Radiant™ tray ensures even
heat distribution, while reducing flare-ups from dripping juices.
18,000-BTU* griddle. The 3/8" thick, stainless steel griddle is
sloped to offer a clean cooking surface. Thermostatic control
ensures even heating and cooking results.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
*15,000 BTU on liquid propane models.
48" professional
ZGU48N4GHSS
gas cooktop
ZGU48L4GHSS
ZGU48N4GHSS, ZGU48N6RHSS and
ZGU48N6DHSS (natural gas)
ZGU48L4GHSS, ZGU48L6RHSS and
ZGU48L6DHSS (liquid propane)
Overall dimensions
(WxHxD in inches):
47-7/8 x 8-7/16 x 26-5/8
Amps @120VAC6.6– 4 burner
3.3– 6 burner
Approx. shipping wt. (lbs.)
324
Gas cookt op s
uses two separate flames to give you a range of precise
temperature options, from an ultralow 140°F simmer to a
powerful 17,000-BTU* setting. The burners are sealed to the
recessed cooktop subsurface for easy cleaning.
• Offers three combinations of
burners, grill and griddle
• Natural or LP gas must be
specified by model number
• Optional 12" or 22" backsplash
accessories
• All burner grates are reversible
to support a round-bottom wok
Induction cookt ops
Sealed, dual-flame stacked burners. Each gas burner
Advance planning for 48" gas professional cooktops
• All professional cooktops are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.
Electrical requirements
Cooktops must be supplied with 120V, 60Hz, and connected
to an individual, properly grounded branch circuit protected
by a 15 amp circuit breaker or time-delay fuse.
Note: Conversion kits (WB49X10132, Natural to LP and
Gas supply
WB49X10133, LP to Natural) are available if the wrong fuel type
was ordered. High altitude kit, WB49X10130 (for Natural and
LP gas models), is also available. This kit includes orifices for
operation at 3,000 to 6,000 feet and another set for operation
at 6,000 or more feet. Conversion kits must be installed by a
qualified service technician at additional cost.
• Natural gas models are designed to operate at 5" water column
pressure. A regulator is required at the natural gas source to
provide maximum of 7" water pressure to the cooktop regulator.
Locate gas
inlet on
back wall
or on floor
2" from
back wall
2"
Elec tr ic c ookt o ps
Professional cooktops offer a number of choices in size and
cooktop configurations.
• The liquid propane models are designed to operate at 10" water
column pressure. A regulator is required at the LP source to
provide maximum of 14" water pressure to the cooktop regulator.
17"
16"
605Dia76
49
Advance planning for 48" professional gas cooktops
48" cooktop surface configurations
Installation options
The 48" Monogram® professional cooktops are available with
a combination of grill, griddle or burners to suit your needs.
• The cooktop stainless steel surface will be 1/2" higher than
adjacent countertops.
ZGU48N4GHSS
with 4 burners,
grill and griddle
(Order ZGU48L4GHSS
for LP gas)
• In 24"-deep cabinets, the front of the cooktop will be
approximately 1-7/8" beyond the front of the countertop.
Cooktop
Flush With
Cabinet Front
Front Flush With
Cabinets - a Minimum
of 25-3/4" Cabinet
Depth Required
ZGU48N6RHSS
with 6 burners and grill
(Order ZGU48L6RHSS
for LP gas)
Cooktop
605Dia81
The serial plate is located
beneath the ledge trim, just
above the left knob.
ZGU48N6DHSS
with 6 burners and griddle
(Order ZGU48L6DHSS
for LP gas)
Backsplash accessories
Front Projects
Outward as Shown
From Standard
Depth Cabinets
605Dia80
The cooktop requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
Product dimensions and clearances
A 54"- or 48"-wide professional vent hood with a minimum
1200 CFM is recommended for installation over this cooktop.
le
Availab sh
Backspla
47-7/8"
Allow Additional
Clearance Below
the Cooktop Burner
Box for the Regulator
and Gas Connections
Install a
matching trim
strip to cover
the cut edge
below the
cooktop.
50
Clearances between Backsplash with warming shelf
cooktop and side wall All Monogram professional wall mount hoods feature
or combustible material
infrared warming lights. The 22"-high backsplash accessory
must be at least 12" on
with warming shelf is a perfect complement when installed
each side.
22"
1/2" 12"
26-5/8"
with the tapered or straight-sided hoods. Restaurant-style
professional hoods are shipped with a stainless steel
backsplash and warming shelf.
8-7/16"
22-3/4"
46-1/8"
ZX12B48HSS, 12" backsplash
ZX22B48HSS, 22" backsplash with warming shelf
7/8"
2-1/2"
8"
Clearances between cooktop and
side wall or combustible material
must be at least 12" on each side.
After the cooktop is installed, the
bottom front edge of the cutout
may need to be covered. Install a
trip strip to match cabinetry along
the bottom of the cooktop.
NOTE: These cooktops require 8" free-space below the burner
box. Allow additional clearance below the burner box for the
regulator and gas ­connections. Use a 90° elbow to route the
gas connections and limit ­interference with drawers or other
cabinetry features.
Side view with a backsplash
12" Min. to
Combustibles
or 0" Min. to
Combustibles
with 12" or 22"
Backsplash
36" Min.
to
Combustibles
monogram.com
Prof e s s ion a l g a s cookt ops
Gas cooktops
36" professional gas cooktop general features
Professional styling. Professional-grade stainless steel
with cast-iron grates makes a striking design statement
in any kitchen.
Unique reversible grates. One side offers a flat surface for
cooking with pots and pans, while the other side is uniquely
contoured to allow stir-frying with a wok.
18,000-BTU* grill. The stainless steel grate is reversible, with
a grooved surface for marinated foods and a rounded side for
searing of meats and fish. A Gourmet Radiant™ tray ensures even
heat distribution, while reducing flare-ups from dripping juices.
18,000-BTU* griddle. The 3/8" thick, stainless steel griddle is
sloped to offer a clean cooking surface. Thermostatic control
ensures even heating and cooking results.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
*15,000 BTU on liquid propane models.
36" professional
gas cooktop
ZGU36N4DHSS
ZGU36L4DHSS
ZGU36N4DHSS, ZGU36N4RHSS and
ZGU36N6HSS (natural gas)
ZGU36L4DHSS, ZGU36L4RHSS and
ZGU36L6HSS (liquid propane)
Overall dimensions
(WxHxD in inches):
35-7/8 x 8-7/16 x 26-5/8
Amps @120VAC3.3– 4 burner
1.0– 6 burner
Approx. shipping wt. (lbs.)
228
Gas cookt op s
uses two separate flames to give you a range of precise
temperature options, from an ultralow 140°F simmer to a
powerful 17,000-BTU* setting. The burners are sealed to the
recessed cooktop subsurface for easy cleaning.
• Offers three combinations
of burners, grill and griddle
• Natural or LP gas must be
specified by model number
• Optional 12" or 22" backsplash
accessories
• All burner grates are reversible
to support a round-bottom wok
Induction cookt ops
Sealed, dual-flame stacked burners. Each gas burner
Advance planning for 36" professional gas cooktops
• All Professional cooktops are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.
Note: Conversion kits (WB49X10132, Natural to LP and
WB49X10133, LP to Natural) are available if the wrong fuel
type was ordered. High altitude kit, WB49X10130 (for Natural
and LP gas models), is also available. This kit includes orifices for
operation at 3,000 to 6,000 feet and another set for operation
at 6,000 or more feet. Conversion kits must be installed by a
qualified service technician at additional cost.
Locate gas
inlet on
back wall
or on floor
2" from
back wall
Electrical requirements
Cooktops must be supplied with 120V, 60Hz, and connected to
an individual, properly grounded branch circuit protected by
a 15 amp circuit breaker or time-delay fuse.
Elec tr ic c ookt o ps
Professional cooktops offer a number of choices in size and
cooktop configurations.
Gas supply
• Natural gas models are designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide maximum of 7" water pressure to the
cooktop regulator.
• The liquid propane models are designed to operate at 10"
water column pressure. A regulator is required at the LP
source to provide maximum of 14" water pressure to the
cooktop regulator.
2"
7"
16"
605Dia84
51
Advance planning for 36" professional gas cooktops
36" cooktop surface configurations
Installation options
The 36" Monogram® professional cooktops are available
with a combination of a grill or griddle and 4 burners, or
simply 6 burners.
• The cooktop stainless steel surface will be 1/2" higher than
adjacent countertops.
ZGU36N4DHSS
with 4 burners and griddle
(Order ZGU36L4DHSS for LP gas)
• In 24"-deep cabinets, the front of the cooktop will be
approximately 1-7/8" beyond the front of the countertop.
Cooktop
Flush With
Cabinet Front
Front Flush With
Cabinets - a Minimum
of 25-3/4" Cabinet
Depth Required
ZGU36N4RHSS
with 4 burners and grill
(Order ZGU36L4RHSS for LP gas)
Cooktop
605Dia81
Front Projects
Outward as Shown
From Standard
Depth Cabinets
ZGU36N6HSS
with 6 burners
(Order ZGU36L6HSS for LP gas)
The serial plate is located beneath the ledge trim, just
above the left knob.
Backsplash accessories
The cooktop requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
Product dimensions and clearances
A 36"- or 42"-wide professional vent hood with a minimum
600 CFM is recommended for installation over this cooktop.
Available
h
Backsplas
35-7/8"
Allow Additional
Clearance Below
the Cooktop Burner
Box for the Regulator
and Gas Connections
22"
1/2" 12"
26-5/8"
8-7/16"
22-3/4"
35"
605Dia80
ZX12B36HSS, 12" backsplash
ZX22B36HSS, 22" backsplash with warming shelf
Clearances between
cooktop and side wall
or combustible materialBacksplash with warming shelf
must be at least 12" on All Monogram professional wall mount hoods feature
infrared warming lights. The 22"-high backsplash accessory
each side.
1/2"
2-1/2"
with warming shelf is a perfect complement when installed
with the tapered or straight-sided hoods. Restaurant-style
professional hoods are shipped with a stainless steel
backsplash and warming shelf.
Side view with a backsplash
Install a
matching trim
strip to cover
the cut edge
below the
cooktop.
52
8"
Clearances between cooktop and side
wall or combustible material must be at
least 12" on each side. After the cooktop
is installed, the bottom front edge of the
cutout may need to be covered. Install
a trip strip to match cabinetry along the
bottom of the cooktop.
Note: These cooktops require 8" free-space below the burner
box. Allow additional clearance below the burner box for the
regulator and gas ­connections. Use a 90° elbow to route the
gas connections and limit ­interference with drawers or other
cabinetry features.
12" Min. to
Combustibles
or 0" Min. to
Combustibles
with 12" or 22"
Backsplash
36" Min.
to
Combustibles
monogram.com
Stainless steel gas cooktop
general features
Prof e s s ion a l g a s cookt ops
Gas cooktops
LO
SIM
HI
LITE
OFF
LO
HI
LITE
OFF
LO
X-HI
LITE
OFF
LO
SIM
HI
LITE
LO
LO
Silent, precise simmering. The simmer flame delivers
a consistent 140°F temperature, without cycling on and off.
No simmer plate required.
Electronic ignition with auto reignition. Instant ignition system
ensures a continuous flame and reignites automatically if
accidentally extinguished.
Hand-machined, stainless steel knob controls. A red indicator
light embedded in each knob makes it easy to view and select
heat settings. Knob controls rotate with smooth precision.
Interlocking, continuous grates. The continuous-grate design
creates a steady surface for cookware, and grates are integrated
into the cooktop for a clean, finished appearance.
USE WITH
LARGER
POTS
SIM
OFF
SIM
SIM
HI
HI
X-HI
LITE
LITE
LO
LO
HI
HI
LITE
OFF
LITE
LITE
OFF
OFF
OFF
ZGU384LSMSS
ZGU385NSMSS
36" stainless
steel
ZGU385LSMSS
gas cooktop
ZGU384NSMSS steel
30" stainless
gas cooktop
ZGU385NSMSS (natural gas)
ZGU385LSMSS (liquid propane)
ZGU384NSMSS (natural gas)
ZGU384LSMSS (liquid propane)
Overall dimensions
(WxHxD in inches):
36-3/4 x 3-3/4 x 21-3/16
Amps @120VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
30-3/4 x 3-3/4 x 21-5/8
Amps @120VAC
Approx. shipping wt. (lbs.)
5.0
68
•Approved installation over
any Monogram single wall
oven (except Trivection), or
warming drawer
•Natural or LP gas must be
specified by model number
5.0
55
•Approved installation over
any Monogram single wall
oven (except Trivection), or
warming drawer
•Natural or LP gas must be
specified by model number
Induction cookt ops
High-output cooking power. Intense heat ideal for searing and
boiling is delivered by an 18,000-BTU* burner, featured on both
36" and 30" cooktops. The 36" model provides a total of 62,000
BTUs,* and the 30" model offers 50,000 BTUs.*
LO
SIM
SIM
OFF
Dual-flame, stacked burners. Simmer-to-boil flexibility on all
burners delivers exceptional performance and convenience. The
burners are sealed to the cooktop for easy cleaning.
USE WITH
LARGER
POTS
SIM
Gas cookt op s
Sophisticated design. Angled and hand-finished to perfection, a
Monogram stainless steel gas cooktop brings an incomparable
mix of edge and elegance to the kitchen.
SIM
Gas-on-glass cooktop general features
Sophisticated styling. The front edge is slightly curved to
form an attractive, soft arc that complements other Monogram
appliances.
LO
HI
LITE
OFF
LO
HI
LO
HI
LITE
range of heat intensities: one 15,000-BTU burner, one 11,000-BTU
burner, one 9100-BTU and two 6000-BTU burners.
Continuous grate design. Heavy pots are easy to slide from
burner to burner.
Soft-touch control knobs. Tactile knobs are pleasing to
the touch and are dishwasher safe.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
LO
LITE
OFF
HI
LO
HI
LITE
OFF
LITE
OFF
36" gas-on-glass
ZGU36KWKWW
cooktop
Elec tr ic c ookt o ps
Precise, versatile temperature control. Five burners provide a
OFF
ZGU36KSKSS,
ZGU36KWKWW and ZGU36KBKBB
Overall dimensions
(WxHxD in inches):
36 x 3-1/16 x 21-7/16—SS
36 x 3-1/16 x 21-1/4—WW/BB
Amps @120VAC
5.0
Approx. shipping wt. (lbs.)
59
• Approved installation over wall
oven or warming drawer
• LP gas conversion kit included
* Natural gas
53
Advance planning for gas cooktops
36" stainless steel gas cooktop
30" stainless steel gas cooktop
Stainless steel cooktops are factory set for natural or liquid
propane gas. Be sure to order the correct model for your
installation.
Stainless steel cooktops are factory set for natural or liquid
propane gas. Be sure to order the correct model for your
installation.
Note: If the wrong fuel type is ordered, the cooktop can be
Note: If the wrong fuel type is ordered, the cooktop can be
converted for other fuel operation. Conversion orifices are
packed with each cooktop. They can be installed by a qualified
service technician at additional cost.
converted for other fuel operation. Conversion orifices are
packed with each cooktop. They can be installed by a qualified
service technician at additional cost.
WB28T10185 High altitude conversion kit is available for
operation above 5,000 feet. This kit includes orifices for both LP
and natural gas.
WB28T10185 High altitude conversion kit is available for
operation above 5,000 feet. This kit includes orifices for both LP
and natural gas.
Electrical requirements
Electrical requirements
This cooktop requires a 120V, 60Hz power supply. A separate
circuit, protected by a 15-amp time-delay fuse or circuit
breaker, is required.
20-5/16” at sides
This cooktop requires a 120V, 60Hz power supply. A separate
circuit, protected by a 15-amp time-delay fuse or circuit
breaker, is required.
21”at sides
ZGU385NSMSS natural gas
ZGU385LSMSS LP gas
ZGU384NSMSS natural gas
ZGU384LSMSS LP gas
21-3/16” at center
36-3/4”
3-3/4”
3-3/8” Min.
from Cutout
to Rear Vertical
Combustibles
12” Min.
from Cutout
to Side Walls
19-1/8”
3-3/4”
19-5/8”
2-7/8“ Min.
from Cutout
to Rear Vertical
Combustibles
2-1/2” Min.
from Cutout
to Front of
Countertop
33-7/8”
2-1/2” Min.
from Cutout
to Front of
Countertop
36” Min.
Cabinet Base
Gas supply
Locate gas and electrical supply
as shown. The gas inlet is located
on the bottom of the burner box, at
the center and 2" from the rear. See
installation instructions for details.
12” Min.
from Cutout
to Side Walls
28-1/2”
30” Min.
Cabinet Base
Gas supply
Locate the gas and electrical supply
as shown. The gas inlet is located on
the bottom of the burner box, 2" from
the right side and 1-1/2" from the rear.
See installation instructions for details.
• The natural gas model is designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide a maximum of 14" water pressure to the
cooktop regulator.
• The natural gas model is designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide a maximum of 14" water pressure to the
cooktop regulator.
• The liquid propane model is designed to operate at 11" water
column pressure. A regulator is required at the LP source to provide
a maximum of 14" water pressure to the cooktop regulator.
• The liquid propane model is designed to operate at 11" water
column pressure. A regulator is required at the LP source to provide
a maximum of 14" water pressure to the cooktop regulator.
Combination installations
Combination installations
Consideration must be given to gas and electrical supply
locations when the cooktop is installed with other products in
the same cabinet. Always refer to each product’s installation
instructions for clearances and electrical requirements.
Consideration must be given to gas and electrical supply
locations when the cooktop is installed with other products in
the same cabinet. Always refer to each product's installation
instructions for clearances and electrical requirements.
• Install these cooktops with any 36" or wider exhaust hood with
350 CFM or greater air flow rating.
• Install these cooktops with any 30" or wider exhaust hood
with 350 CFM or greater air flow rating.
• This cooktop may be installed above a Monogram single oven.
• This cooktop may be installed in combination with a
Monogram downdraft vent. See downdraft vents for details.
• This cooktop may be installed in combination with a
Monogram® 36" downdraft vent or above a Monogram 30"
warming drawer. See downdraft vents and warming drawers
for details.
54
21-5/8”at center
30-3/4”
• This cooktop may be installed above a Monogram
warming drawer. See warming drawers for details.
• This cooktop may be installed above a Monogram single oven.
The serial plate is located on the bottom of the cooktops.
monogram.com
Gas-on-glass cooktops
Gas supply
Gas-on-glass cooktops are factory set for natural gas operation.
They can be converted to LP operation with a conversion kit
shipped with the cooktop.
• These cooktops are designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide a maximum of 7" water pressure to the
cooktop regulator.
Electrical requirements
• When converted to liquid propane operation, they are
designed to operate at 10" water column pressure. A regulator
is required at the LP source to provide a maximum of 14" water
pressure to the cooktop regulator.
21-1/4" B/W
Deep at Center
36"
3-1/16"
2-1/4" Min.
to Rear Vertical
Combustibles
6" Min.
Cutout
To Side
Walls
19-1/8"
33-7/8"
Consideration must be given to gas and electrical supply
locations when the cooktop is installed with other products in
the same cabinet. Always refer to each product's installation
instructions for clearances and electrical requirements.
• Install these cooktops with any 36" or wider exhaust hood
with 300 CFM or greater air flow rating.
• This cooktop may be installed in combination with a
Monogram 36" downdraft vent. See downdraft vents
for details.
2-1/2"
Min. From
Front of
Countertop
• This cooktop may be installed above a Monogram
30" warming drawer. See warming drawers for details.
Induction cookt ops
ZGU36KSKSS Black
with stainless steel trim
ZGU36KBKBB Black
ZGU36KWKWW White
Combination installations
Gas cookt op s
This cooktop requires a 120V, 60Hz power supply.
A separate circuit, protected by a 15-amp time-delay
fuse or circuit breaker, is required. The receptacle should
be checked by a qualified electrician for correct
polarity and proper grounding.
21-7/16" SS
Prof e s s ion a l g a s cookt ops
Advance planning for gas cooktops
• This cooktop may be installed above a Monogram single oven.
Locate the gas on the right side,
1" forward of the back of the cutout.
Install an electrical outlet 12" below
the countertop.
605Dia121
The serial plate is located on the bottom of the cooktops.
605Dia120
Elec tr ic c ookt o ps
1" Min. Forward of
Back of Cutout
55
Induction cooktops
Induction cooktop general features
Induction technology. Induction elements use electricity
to produce a magnetic field that reacts with the iron in metal
cookware —including cast iron and magnetic stainless steel
pans—and transfers the heat to the cookware.
Sophisticated styling. Stainless steel-framed models have a
reflective metallic finish that captures light and colors inside the
kitchen. Black models are smooth from edge to edge, making
them easy to clean.
Digital controls. Controls are embedded in the cooktop offer
added style and convenience.
3,700-watt, 11" element. This element is the most powerful
induction element in the industry.* It provides instantaneous heat
across 19 different cooking settings.
Digital pan-sensing technology. Detects the presence
of cookware with magnetic properties, a requirement for
induction cooking.
Pan size sensor. Automatically adjusts the heating element to
the size of the pan.
Warm setting. Provides just enough heat to maintain an ideal
serving temperature.
Timer, control-lock capability and hot-surface indicator.
Each setting provides an extra measure of convenience
and safety.
Flexible installation. Monogram induction cooktops may be
installed above a Monogram single wall oven, and is possible
due to a shallow-depth configuration of the cooktops and an
integrated cooling system.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
*Among leading manufacturers' brands.
56
36" induction cooktop
30" induction cooktop
ZHU36RSMSS and ZHU36RBMBB
ZHU30RSMSS and ZHU30RBMBB
Overall dimensions
(WxHxD in inches):
36-1/8 x 4-5/8 x 21—SS
36 x 4-5/8 x 20-7/8
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
29-7/8 x 4-5/8 x 21-1/2—SS
29-3/4 x 4-5/8 x 21-3/8
Amps @240VAC
32.3
208VAC
27.9
Approx. shipping wt. (lbs.)
49
ZHU36RSMSS
• Requires a 50-amp circuit
• Approved installation over
Monogram® wall oven
48.3
41.8
59
ZHU30RSMSS
• Requires a 40-amp circuit
• Approved installation over
Monogram wall oven
monogram.com
Electrical requirements
Combination installations
Product rating is 120/208 or 120/240V, 60Hz, 36" cooktops
require a 50-amp circuit; and 30" cooktops require a 40-amp
circuit. The cooktops must be connected to a supply circuit of
the proper voltage and frequency and protected by a timedelay fuse or circuit breaker.
Consideration must be given to electrical supply locations when
the cooktop is installed with other products in the same cabinet.
Always refer to each product’s installation instructions for
clearances and electrical requirements.
• The 30" cooktop may be installed in combination with a
Monogram 30" downdraft vent. Install the 36" cooktop with
a 36" downdraft vent. See downdraft vents for details.
Junction
Box
4-5/8" at
Front Baffle
605Dia125
ZHU30RSMSS Stainless Metallic
ZHU30RBMBB Black
Note: When the cooktop
is installed over an oven,
the baffle at the front is
not required.
A
The serial plate is located on the bottom of the cooktops.
B
2" Min.
to Side Walls
1-3/4"
Min.
19-5/8"
• A Monogram single oven may be installed below these cooktops.
Gas cookt op s
3-1/4"
All models require 12"
minimum ­clearance below
the cooktop bottom to
combustible materials.
• Install these cooktops with any exhaust hood of the same or
greater width; 300 CFM or greater air flow rating is recommended.
2-1/2" Min.
to Front Edge
Induction cookt ops
16" Min
Prof e s s ion a l g a s cookt ops
Advance planning for induction cooktops
28-1/2"
30" induction cooktop (in inches)
A
ZHU30RSMSS ZHU30RBMBB 29-7/8" 20-15/16"
29-3/4" 20-13/16"
B (depth at sides)
B (at center)
21-1/2"
21-3/8"
ZHU36RSMSS Stainless Metallic
ZHU36RBMBB Black
A
B
2" Min.
to Side Walls
1-3/4"
Min.
19-1/8"
Elec tr ic c ookt o ps
605Dia124
2-1/2" Min.
to Front Edge
33-7/8"
36" induction cooktop (in inches)
A
ZHU36RSMSS ZHU36RBMBB 36-1/8" 20-15/32"
36"
20-5/16"
B (depth at sides)
B (at center)
21"
20-7/8"
605Dia123
57
Electric cooktops
Digital electronic cooktop
general features
Sophisticated styling. Flat plane of smooth ceramic glass
provides a near-seamless cooking surface.
TIMER
Rapid Hi/Lo burner cools down up to three times faster
than an electronic standard burner. Rapid reduction in heat
helps prevent sauces from boiling over or burning.
Dual elements. Radiant heating elements with responsive
sensors accommodate small to large pans for enhanced cooking
flexibility and performance.
Full-function warmer. Positioned at center on 36" models and
right rear on 30" models, the convenient warmer offers three
warm settings, in addition to the 11 standard heat settings.
ZEU36RSFSS and ZEU36RBFBB
ZEU30RSFSS and ZEU30RBFBB
Overall dimensions
(WxHxD in inches):
36-1/8 x 6-1/4 x 21-1/4—SS
36 x 6-1/4 x 21-1/8
Amps @240VAC
35.8
208VAC
31.3
Approx. shipping wt. (lbs.)
56
Overall dimensions
(WxHxD in inches):
29-7/8 x 6-1/4 x 21-3/4—SS
29-3/4 x 6-1/4 x 21-5/8
Amps @240VAC
30.8
208VAC
26.9
Approx. shipping wt. (lbs.)
43
• Approved installation over
Monogram® wall oven or
warming drawer
• Approved installation over
Monogram wall oven or
warming drawer
Cooking versatility. Elements vary from 6" to 12" in diameter
and can be expanded to suit your cooking needs.
Cooking performance. Responsive ribbon elements allow you
to simmer and sauté precisely according to recipe. An infinite
range of heat settings leaves plenty of room for improvisation.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
36" ribbon electric
cooktop
ZEU36KSKSS, ZEU36KWKWW and
ZEU36KBKBB
Overall dimensions
(WxHxD in inches):
36-1/8 x 3-1/4 x 21-1/4—SS
36 x 3-1/4 x 21-1/8
Amps @240VAC
40.8
208VAC
35.4
Approx. shipping wt. (lbs.)
45
• Requires a 50-amp circuit
58
ZEU30RWF.EPS
30" ribbon digital
electric cooktop
stunning look of sleek simplicity, and the surface is completely
solid for a dramatic “true black” or “true white” appearance.
you to create larger heating zones to match your cooking needs.
SENSORS
36" ribbon
digital
ZEU36RWF.EPS
electric cooktop
Electric cooktop general features
Sophisticated styling. The flush, frameless design offers a
Expandable elements. Triple-ring and bridge elements allow
TIMER
SENSORS
monogram.com
Electrical requirements
Combination installations
Product rating is 120/208 or 120/240V, 60Hz. For 240V,
connect to a 40-amp circuit; connect to a 30-amp circuit for
208V operation. The cooktops must be connected to a
supply circuit of the proper voltage and frequency and
protected by a time-delay fuse or circuit breaker.
Consideration must be given to electrical supply locations when
the cooktop is installed with other products in the same cabinet.
Always refer to each product’s installation instructions for
clearances and electrical requirements.
6-1/4"
Junction
Box
5-1/2"
All models require 5" minimum
clearance below the cooktop bottom
to combustible materials.
605Dia126
• Install these cooktops with any exhaust hood of the same or
greater width; 300 CFM or greater air flow rating is recommended.
• The 30" cooktop may be installed in combination with a
Monogram 30" downdraft vent. Install the 36" cooktop with
a 36" downdraft vent. See downdraft vents for details.
• A 27" warming drawer may be installed beneath a 30" digital
cooktop, and a 30" warming drawer may be installed beneath
a 36" digital cooktop.
Gas cookt op s
3-1/4"
16" Min
Prof e s s ion a l g a s cookt ops
Advance planning for electric cooktops
• A Monogram single oven may be installed below these cooktops.
2" Min.
to Side Walls
1-3/4"
Min.
19-5/8"
The serial plate is located on the bottom of the cooktops.
B
2-1/2" Min.
to Front Edge
Product rating is 120/208 or 120/240V, 60Hz. For 240V, connect
to a 50-amp circuit; connect to a 40-amp circuit for 208V
operation. The cooktop must be connected to a supply circuit
of the proper voltage and frequency and protected by a timedelay fuse or circuit breaker.
28-1/2"
30" digital cooktop (in inches)
A
ZEU30RSFSS ZEU30RBFBB 29-7/8" 21-5/8"
29-3/4" 21-1/2"
B (at center)
605Dia124
ZEU36RSFSS Black with
stainless steel trim
ZEU36RBFBB Black
A
ZEU36KSKSS Solid black with stainless steel trim
ZEU36KWKWW Solid white
ZEU36KBKBB Solid black
36-1/8" SS
36" B/W
*3-1/4"
16" Min
33-7/8"
A
ZEU36RSFSS ZEU36RBFBB 36-1/8" 21-1/4"
36"
21-1/8"
B (at center)
605Dia123
2-1/2"
Min.
to Front
Edge
Junction
Box
36" digital cooktop (in inches)
2" Min.
to Side Walls
33-7/8"
19-1/8"
2" Min.
to Side Walls
2-1/2" Min.
to Front Edge
21-1/4" SS
21-1/8" B/W
Deep at
Center
1-3/4"
Min.
B
1-3/4"
Min.
19-1/8"
Electrical requirements
Induction cookt ops
A
Elec tr ic c ookt o ps
605Dia125
ZEU30RSFSS Black with
stainless steel trim
ZEU30RBFBB Black
605Dia125
*3-1/4" deep at the front.
4-5/8" deep at the rear conduit
location. Requires 5" minimum
clearance below the cooktop
bottom to combustible materials.
605Dia128
Combination installations
Consideration must be given to electrical supply locations when
the cooktop is installed with other products in the same cabinet.
Always refer to each product’s installation instructions for
clearances and electrical requirements.
• Install these cooktops with any exhaust hood of the same
or greater width; 300 CFM or greater air flow rating is
recommended.
• The cooktop may be installed with a 36" Monogram downdraft
vent. See downdraft vents for details.
59
Pairing hoods with cooking equipment
Monogram® hoods are designed to perfectly coordinate with Monogram ranges and cooktops. To learn which cooking products can
be combined with the hood you have selected, refer to the charts below.
Wall-mounted
Island
ZV750SY
ZV950SDSS
ZV800SJ/BJ
ZV900SL
ZV850SB
ZV1050SFSS
ZV925SL
Downdraft
ZVB36SH/WH/BH
ZVB30SH/BH
All non-pro
cooktops
All 30" & 36"
cooktops and
ranges
All non-pro
cooktops
All non-pro
cooktops
All non-pro
cooktops
All 30" & 36"
cooktops and
ranges
All non-pro
cooktops
All non-pro
cooktops
Chimney
Chimney
Chimney
(slide-out)
Chimney
Chimney
Chimney
Chimney
Integrated
36"
36"
36"
36"
36"
42"
36"
36"/30"
360 CFM
700 CFM
500 CFM
570 CFM
360 CFM
1080 CFM
570 CFM
500 CFM
8'-10' options
No
8'-10' options
8'-10' 5" options 8'-10' options
No
8'-10' 1" options No
8', 9' duct cover
included;
10' duct
cover optional
8', 9' or 10' duct
cover included;
10' to 14' duct
cover optional
8' to 10'
duct cover
included; or
undercabinet
option
8' to 9' 5" duct
cover included;
9' 6" to 10' 5"
duct
cover optional
8', 9' or 10' duct
cover required,
must order
separately
8' duct cover
included, 9' or
10' duct cover
optional
8' to 9' duct
cover included;
9' 1" to 10' 1"
Indoor, outdoor
duct
remote blower
cover optional options
6" round
8" round
6" round
8" round
6" round
8" round
8" round
3-1/4" x 10" rect.
100'
100'
100'
100"
100'
100'
100'
150'
Installation
combinations
Style
Width
Blower rating
Recirculating option
Vented duct
cover options
Duct size
Equivalent
duct length
Professional wall-mounted
ZV48TSFSS
ZV48SSFSS
ZV36TSFSS
ZV36SSFSS
ZV30TSFSS
ZV30SSFSS
ZV48RSFSS
ZV36RSFSS
ZV30RSFSS
ZV42ISHSS
ZV54ISHSS
Wall or island
hood inserts
ZVC48LSS
ZVC36LSS
Zvc30LSS
All Monogram
cooktops and
ranges
All Monogram
cooktops and
ranges
All Monogram
cooktops and
ranges
All 30" & 36"
cooktops
All Monogram
cooktops and
ranges
All 30", 36" and
48" cooktops
and ranges
Tapered
Straight
Restaurant
Tapered
Tapered
Insert
48"/36"/30"
48"/36"/30"
48"/36"/30"
42"
54"
48"/36"/30"
1200/640/640 CFM
1200/640/640 CFM
1200/640/640 CFM
1200 CFM
1200 CFM
1200/640/640 CFM
No
No
No
No
No
No
Optional 6" and 12"
duct covers
–stackable
Optional 6" and
12" duct covers,
standard or
full-width
–stackable
Optional 6" and
12" duct covers,
standard or
full-width
–stackable
8' duct cover
included,
9' to 10' duct
cover optional
8' duct cover
included,
9' to 10' duct
cover optional
N/A
10" round
10" round
10" round
10" round
10" round
8" round
150'
150'
150'
150'
150'
100'
Professional island
Installation combinations
Style
Width
Blower rating
Recirculating option
Vented duct cover options
Duct size
Equivalent duct length
60
monogram.com
chimney hoods
Chimney hoods—wall-mount
General features
Attractive design. Expertly crafted with uncompromising
attention to detail, a Monogram hood adds a striking
architectural highlight to your kitchen.
Halogen lighting. Six levels of intensity are offered for
different needs, from accent to ambient settings.
36" wall-mount glass
canopy hood
36" wall-mount
ZV950SY.EPS
vent hood
Removable filters. Filters can be easily detached from
the hood for safe cleaning in your dishwasher.
ZV900SLSS
ZV950SDSS
Recirculating kit options for ZV750.
An optional vent hood kit for recirculating operation
can be installed on the ZV750 hood. ZV800 and ZV900
models are designed to be vented outdoors or to recirculate
into the room air. (Air deflector, charcoal filter and a reversible
duct cover is packed with models ZV800 and ZV900.)
Overall dimensions
(WxHxD in inches):
35-7/8 x 3-1/4 x 20-7/16
Amps @ 120VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
35-5/8 x 10 x 25
Amps @ 120VAC
Approx. shipping wt. (lbs.)
4.3
123
4.5
110
Custom hood inser ts
• Dual blowers
• 8" round exhaust duct
• 8'-10' ceiling duct cover
included
• Optional extension
duct covers available
• Dual blowers
• 8" round exhaust duct
• 8'-9' 5" ceiling duct
cover included
• Optional extension duct
covers available
• Reversible duct cover for
vented or recirculating
installations.
Monogram
te l e s c o p i c
d o w n d r a f t v e nt s
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
ZV900SJSS
professional hoods
Powerful ventilation. The variable-speed fan blower provides
the power necessary to capture the smoke and fumes
produced by high-performance cooking equipment.
ZV800SJSS
36" wall-mount
vent hood
ZV750SY
36" wall-mount hood
with retractable
glass canopy
ZV750SY
Overall dimensions
(WxHxD in inches):
34-5/8 x 8-1/4 x 21-5/8
Amps @ 120VAC
Approx. shipping wt. (lbs.)
• 6" round exhaust duct
• 8'-9' ceiling duct cover
included
• Optional extension duct
cover available
• Optional recirculating kits
available
ZV800SJSS
ZV800BJBB
2.7
81
Overall dimensions
(WxHxD in inches):
36 x 1-1/2 x 18-15/16 (with hood
extended)
Amps @ 120VAC
3.3
Approx. shipping wt. (lbs.)
100
• 6" round exhaust duct
• 8'-10' ceiling duct cover
included
• Reversible duct cover for
vented or recirculating
installations
61
Advance planning for chimney hoods—wall-mount
Wall-mount hoods
Ductwork for Z V750SY
Chimney vent hoods are available in a 36" width. All models
are supplied with a two-piece stainless steel duct cover to
conceal the ductwork running from the top of the hood to
the ceiling.
This vent hood must use 6" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation
instructions.
• The installation height should be determined in advance.
If necessary, accessories for height adjustment should be
ordered with the vent hood and be on-site at the time of
installation.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8-ft. to 9-ft. ceiling. ZX10SY can be
ordered to reach 9-ft. to 10-ft. ceiling heights.
• Review the following chart to determine the need for an
accessory duct cover.
Recirculating installation for Z V750
Duct cover accessories for vented installations
Ceiling height
8 ft.
Up to 9 ft.
Up to 10 ft.
10 ft. to 14 ft.
ZV750
Included
Included
ZX10SY
—
ZV950
Included
Included
Included
ZX14SDSS
ZV800
Included
Included
Included
—
ZV900
up to 9'5"
up to 9'5"
ZX90010*
—
*ZX90010 for 9'6" up to 10'5"
Structural suppor t
These vent hoods are heavy. Adequate structural support
must be provided. Hoods must be secured to vertical studs
in the wall or to horizontal supports.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on-site before final framing and wall
finishing. This will help to accurately locate the ductwork
and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
• Mounting templates are provided with the installation
instructions to help accurately position the hood above the
cooking surface.
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15 or 20 amp circuit breaker or time delay fuse.
Ductwork planning
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
62
The ZV750 hood is designed to be vented to the outside,
but can easily be converted for recirculating operation.
Recirculating kits are available for
this hood. These kits include charcoal
filters, an air deflector that fits over the
exhaust outlet and a vented decorative
duct cover. Kits are sized for ceiling height.
Recirculating installations
Up to 9 ft. ceiling ZXR758C
Up to 10 ft. ceiling ZXR7510C
605Dia145
Ductwork for Z V80 0SJSS, Z V80 0BJBB
This vent hood must use 6" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation
instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8-ft. to 10-ft. ceiling. The duct covers
are reversible for recirculating operation.
Ductwork for Z V9 0 0SL SS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover to reach an 8-ft. to 9'5" ceiling. ZX90010 can be ordered
to reach 9'6" to 10'5" ceiling heights. All duct covers are
reversible for recirculating operation.
Ductwork for Z V950SDSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8-ft. to 10-ft. ceiling. An optional
accessory, ZX14SDSS, can be ordered to reach 10-ft. to 14-ft.
ceiling heights. For vented operation only.
monogram.com
Product dimensions and clearances
Using duct cover accessories
This stainless steel hood can be installed over any Monogram®
cooktop except professional models.
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
which accessory may be required for your installation.
Model ZV750SY
*26-1/4" for 8-ft. ceiling
38-1/4" for 9-ft. ceiling
ZV750SY installation heights
34-5/8"
21-5/8"
605Dia148
*25-1/2" Recommended
36" Min.
This vent hood must be installed 24" min. to 30" max. above the
cooking surface; 25-1/2" is recommended to insure that the
duct cover meets the ceiling. The cooking surface should be
at least 36" above the floor.
605Dia149
professional hoods
8-1/4"
Recirculating
accessory
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR758C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
ZXR7510C
Custom hood inser ts
With accessory
ZX10SY duct cover:
38-1/4" to 50-1/4" for
9-ft. to 10-ft. ceiling.
Duct
cover
accessory
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZX10SY
ZV750SY duct cover dimensions
Model
Accessory
A
B
ZV750SY
Supplied
18-7/8"
22-13/16"
ZV750SY
ZX10SY
—
34-1/4"
ZV750SY
ZXR758C
18-7/8"
22-13/16"
ZV750SY
ZXR7510C
18-7/8"
34-5/8"
te l e s c o p i c
d o w n d r a f t v e nt s
*Height
to Ceiling
Actual
Possible hood
ceiling
installation
height
height*
7' 11"
24-1/2"
8' 0"
25-1/2"
8' 1"
25-1/2" to 26-1/2"
8' 2"
25-1/2" to 27-1/2"
8' 3"
25-1/2" to 28-1/2"
8' 4"
25-1/2" to 29-1/2"
8' 5"
25-1/2" to 30"
8' 6"
25-1/2" to 30"
8' 7"
25-1/2" to 30"
8' 8"
25-1/2" to 30"
8' 9"
25-1/2" to 30"
8' 10"
25-1/2" to 30"
8' 11"
25-1/2" to 30"
9' 0"
25-1/2" to 30"
9' 1"
25-1/2" to 30"
9' 2"
25-1/2" to 30"
9' 3"
25-1/2" to 30"
9' 4"
25-1/2" to 30"
9' 5"
25-1/2" to 30"
9' 6"
25-1/2" to 30"
9' 7"
25-1/2" to 30"
9' 8"
25-1/2" to 30"
9' 9"
25-1/2" to 30"
9' 10"
25-1/2" to 30"
9' 11"
25-1/2" to 30"
10' 0"
25-1/2" to 30"
*Based on 36" countertop height.
chimney hoods
Advance planning for chimney hoods—wall-mount
The serial plate is located behind the
removable filters.
63
Advance planning for chimney hoods—wall-mount
Product dimensions and clearances
Using duct cover accessories
This stainless steel hood can be installed over any Monogram®
cooktop including a professional 36" cooktop and a 36" or 30"
professional range.
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
installation height and the need for a duct cover accessory.
This vent hood must be installed 24" min. to 30" max. above
the cooking surface. The hood installation height, from the
cooktop surface to the bottom of the hood, depends upon
ceiling height.
Model ZV950SDSS
*24-1/2" for 8-ft. ceiling
36-1/2" for 9-ft. ceiling
36" to 44" for 9-ft. to 10-ft.
ceiling. (for ceilings between
9'6" and 10 ft. mount
the hood 30" above the
cooking surface).
*Height
to Ceiling
10"
25"
35-5/8"
Note: The supplied two-piece duct cover is adjustable to
fit 8-ft. to 10-ft. ceilings. For ceiling heights greater than
10 ft. and up to 14 ft., order ZX14SDSS stainless steel duct
cover accessory.
605Dia146
The distance between the cooking surface and the bottom
of the hood should be:
25-1/2" max. for 8-ft. ceiling height.
25-1/2" to 30" for 9-ft. ceiling height.
30" min. for 10-ft. ceiling height.
ZV950SDSS installation heights
Actual
Possible hood
ceiling
installation
height
height*
7' 11"
24-1/2"
8' 0"
25-1/2"
8' 1"
25-1/2" to 26-1/2"
8' 2"
25-1/2" to 27-1/2"
8' 3"
25-1/2" to 28-1/2"
8' 4"
25-1/2" to 29-1/2"
8' 5"
25-1/2" to 30"
8' 6"
25-1/2" to 30"
8' 7"
25-1/2" to 30"
8' 8"
25-1/2" to 30"
8' 9"
25-1/2" to 30"
8' 10"
25-1/2" to 30"
8' 11"
25-1/2" to 30"
9' 0"
25-1/2" to 30"
9' 1"
26-1/2" to 30"
9' 2"
26-1/2" to 30"
9' 3"
26-1/2" to 30"
9' 4"
26-1/2" to 30"
9' 5"
26-1/2" to 30"
9' 6"
30" 9' 7"
30" 9' 8"
30" 9' 9"
30" 9' 10"
30" 9' 11"
30" 10' 0" - 14" 0" 30"
*Based on 36" countertop height.
ZV950DSS duct
cover dimensions
Duct
cover
accessory
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
ZX14SDSS
ZX14DSS duct
cover dimensions
Installation
Height Depending
on Ceiling Height
36" Min.
Plan the installation height carefully to avoid unsightly gaps
above the hood.
605Dia147
Note: Install the hood 30" min. above the cooking surface
over a professional range or cooktop.
Installation over a professional range
or cooktop
The ZV950 hood must be installed 30" minimum above the
cooking surface of a professional range or cooktop. The ceiling
height must be at least 8' 5" for this installation combination.
64
The serial plate is located behind the removable filters.
monogram.com
Product dimensions and clearances
Determine installation height
This vent hood can be installed for vented or recirculating
operation. It can be installed over any Monogram cooktop
(except Professional models).
Use this chart to accurately determine installation heights,
depending on your ceiling heights.
chimney hoods
Advance planning for chimney hoods—wall-mount
Wall-mount ZV800 installation heights
Venting and recirculating
wall-mount installations
The vent hood must be
installed 24" min. to 30"
max. above the standard
36" countertop. The hood
installation height, from
the cooking surface to the
bottom of the hood, depends
on the ceiling height.
Vented or recirculating
installations in a cabinet
Possible recirculating
installation
24" to 25"
24" to 26"
24" to 27"
24" to 28"
24" to 29"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
25" to 30"
26" to 30"
professional hoods
The canopy extends
forward 5-7/8".
Actual ceiling
Possible vented
height
installation height*
7' 11"
24" to 27"
8' 0"
24" to 28"
8' 1"
24" to 30"
8' 2"
24" to 30"
8' 3"
24" to 30"
8' 4"
24" to 30"
8' 5"
24" to 30"
8' 6"
24" to 30"
8' 7"
24" to 30"
8' 8"
24" to 30"
8' 9"
24" to 30"
8' 10"
24" to 30"
8' 11"
24" to 30"
9' 0"
24" to 30"
9' 1"
24" to 30"
9' 2"
24" to 30"
9' 3"
24" to 30"
9' 4"
24" to 30"
9' 5"
24" to 30"
9' 6"
24" to 30"
9' 7"
25" to 30"
9' 8"
26" to 30"
9' 9"
27" to 30"
9' 10"
28" to 30"
9' 11"
29" to 30"
10' 0"
30"
*Based on 36" countertop height.
Custom hood inser ts
ZV800SJSS, Stainless steel
ZV800BJBB, Black
Telescoping duct covers
are provided to reach
8 ft. to 10 ft. ceiling
heights.
The vent hood height must
be at least 24" min. above
the standard 36" countertop.
• In both vented and
recirculating installations,
the cabinet must measure
at least 20" from the bottom
frame to the inside top.
Louver at top of cabinet
in this example
te l e s c o p i c
d o w n d r a f t v e nt s
• The cabinet must be at
least 12" deep. The hood
housing will occupy the
interior cabinet space.
ZV800SJSS and JV800BJBB duct cover dimensions
The serial plate is located behind the removable filters.
Recirculating installation
• The exhaust must be returned to the kitchen; it cannot exit
inside the cabinet.
• The exhaust can be directed through the soffit or upper
cabinet to a vent opening with a minimum of 28 square
inches or 6" round. A customer-supplied decorative louver
should be installed.
• The exhaust should be directed away from other cabinet
surfaces, either exposed or hidden.
65
Advance planning for chimney hoods—wall-mount
Product dimensions and clearances
Determine installation height
This glass canopy hood can be installed over any Monogram®
cooktop (except Professional models).
Use this chart to accurately determine installation heights,
depending on your ceiling heights.
Model ZV900SLSS
*The supplied duct
cover is sized to
fit 8' to 9'5" ceiling
heights. For 9' 6"
to 10' 5" ceilings,
order ZX90010
*Height
to
Ceiling
20 7/16"
3 1/4"
35 7/8"
NOTE: Measure
installation height
from the cooking
surface to the
outer glass portion
of the hood.
24" Min.
30" Max.
36" Min.
• The vent hood must be installed 24" min., and 30" max.
above the cooking surface. The hood installation height
above the cooking surface depends upon the ceiling height.
• The cooking surface should be at least 36" above the floor.
• This hood can be installed for recirculating operation.
No kits required.
ZV900SLSS duct cover dimensions
NOTE: ZX90010 accessory consists of one 40" long duct cover.
The serial plate is located behind the removable filters.
66
Wall-mount ZV900 installation heights
Actual
Possible vented
Possible
ceiling
installation
recirculating
height
height*
installation*
7' 11"
24" to 26"
24" to 25"
8' 0"
24" to 27"
24" to 26"
8' 1"
24" to 28"
24" to 27"
8' 2"
24" to 29"
24" to 28"
8' 3"
24" to 30"
24" to 29"
8' 4"
24" to 30"
24" to 30"
8' 5"
24" to 30"
24" to 30"
8' 6"
24" to 30"
24" to 30"
8' 7"
24" to 30"
24" to 30"
8' 8"
24" to 30"
24" to 30"
8' 9"
24" to 30"
24" to 30"
8' 10"
24" to 30"
24" to 30"
8' 11"
24" to 30"
24" to 30"
9' 0"
24" to 30"
24" to 30"
9' 1"
26" to 30"
24" to 30"
9' 2"
27" to 30"
24" to 30"
9' 3"
28" to 30"
24" to 30"
9' 4"
29" to 30"
24" to 30"
9' 5"
30"
24" to 30"
9' 6"
24" to 30"
24" to 30"
9' 7"
24" to 30"
24" to 30"
9' 8"
24" to 30"
24" to 30"
9' 9"
24" to 30"
24" to 30"
9' 10"
24" to 30"
24" to 30"
9' 11"
24" to 30"
24" to 30"
10' 0"
24" to 30"
24" to 30"
10' 1"
24" to 30"
24" to 30"
10' 2"
25" to 30"
24" to 30"
10' 3"
26" to 30"
25" to 30"
10' 4"
27" to 30"
26" to 30"
10' 5"
28" to 30"
27" to 30"
*Based on 36" countertop height.
Duct cover
accessory
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
ZX90010
monogram.com
chimney hoods
Chimney hoods—islands
General features
Attractive design. Expertly crafted with uncompromising
attention to detail, a Monogram hood adds a striking
architectural highlight to your kitchen.
Powerful ventilation. The variable-speed fan blower provides
the power necessary to capture the smoke and fumes
produced by high-performance cooking equipment.
Monogram
Halogen lighting. Six levels of intensity are offered for
different needs, from accent to ambient settings.
36" island vent hood
Removable filters. Filters can be easily detached from
the hood for safe cleaning in your dishwasher.
ZV850SB
professional hoods
ZV925SLSS
Overall dimensions
(WxHxD in inches):
35-3/8 x 8-1/4 x 27-1/2
Amps @ 120VAC
Approx. shipping wt. (lbs.)
2.7
81
• 6" round exhaust duct
• Required duct covers must be
ordered separately
• Optional recirculating kits
available
Overall dimensions
(WxHxD in inches):
35-7/8 x 3-3/4 x 27-9/16
Amps @ 120VAC
Approx. shipping wt. (lbs.)
4.6
146
• 8" round exhaust duct
• 8'–9' duct cover included
• Optional extension duct
covers available
• Reversible duct cover for
vented or recirculating
installation
Custom hood inser ts
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
ZV850SB
42" island vent hood
ZV1050SFSS
te l e s c o p i c
d o w n d r a f t v e nt s
Recirculating options. An optional vent hood kit for
recirculating operation can be installed on the ZV850.
Model ZV925 is designed to be vented outdoors or to
recirculate into the room air.
ZV900SJSS
36" island glass canopy
vent hood
ZV1050SFSS
Overall dimensions
(WxHxD in inches):
42 x 10 x 31-1/2
Amps @ 120VAC
Approx. shipping wt. (lbs.)
6.7
150
• Dual blowers
• 8" round exhaust duct
• 8' ceiling duct cover
included
• Optional extension
duct covers available
67
Advance planning for chimney hoods—island
Stainless steel island hoods
Ductwork for Z V850SB
Chimney vent hoods are available in 42" and 36" widths.
This vent hood must use 6" round duct.
• Duct cover accessories to meet ceiling heights are required
for the ZV850 island hood. One accessory must be ordered
with the vent hood.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• The ZV925 vent hood is supplied with a two-piece decorative
duct cover to reach an 8-ft. to 9-ft. ceiling. An optional duct
cover accessory is available for 9'1" to 10'1" ceiling heights.
• For satisfactory performance, duct run should not exceed
100 feet equivalent length for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
• The ZV1050 hood is supplied with a duct cover for an 8-ft.
ceiling height (7' 11" to 8' 1"). Optional duct cover accessories
are available for 9-ft. and 10-ft. ceiling heights.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
• The installation height must be determined in advance for
both models.
• All duct cover accessories must be ordered with the vent
hood and be on-site at the time of installation.
• Review the following chart to determine the appropriate
accessory duct cover.
Required duct cover accessories for vented installations
Ceiling height
8 ft.
Up to 9 ft.
Up to 10 ft.
ZV850
ZX858SB
ZX859SB
ZX8510SB
ZV925
Supplied
Supplied
ZX92510
ZV1050
Supplied
ZX1059SFSS
ZX10510SFSS
Structural suppor t
These vent hoods are heavy. Adequate structural support
must be provided. Hoods must be secured to cross framing
positioned between ceiling joists.
• The vent hood and duct cover(s) must be on-site before final
framing and wall finishing. This will help to accurately locate
the ductwork and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
• Mounting templates are provided with the installation
instructions to help accurately position the hood on the
ceiling above the cooking surface.
• Use metal ductwork only.
Ductwork for Z V925SL SS
This vent hood must use 8" round duct.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• For satisfactory performance, duct run should not exceed
100 feet equivalent length for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
Ductwork for Z V1050SFSS
This vent hood must use 8" round duct.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• For satisfactory performance, duct run should not exceed
100 feet equivalent length for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Recirculating installation
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15 or 20 amp circuit breaker or time delay fuse.
• The junction box is located on top of the hood. Route the
wiring as close to the installation as possible through the
ceiling. Refer to the installation instructions for details.
The ZV850 hood is designed to be vented to the outside, but it
can easily be converted for recirculating operation.
Recirculating kits are available for the ZV850 hood. These kits
include charcoal filters, a support frame with air deflector and a
vented decorative duct cover to complete
the installation. Kits are sized for ceiling height.
Recirculating installations
8 ft. ZXR858C
9 ft. ZXR859C
10 ft.
ZXR8510C
The ZV925SLSS is designed for either vented or recirculating
operation. All necessary parts are included.
605Dia152
The ZV1050 is not convertible to recirculating operation.
68
monogram.com
Product dimensions and clearances
Using duct cover accessories
This stainless steel hood can be installed over any Monogram®
cooktop except Professional models. Accessories to meet
correct ceiling heights are required.
A duct cover accessory is required for all ceiling heights.
Use this chart to determine the correct duct cover accessory
for 8-ft. to 10-ft. ceilings that must be ordered with the hood.
Model ZV850SB
*26-1/4" for 8-ft. ceiling using
ZX858SB accessory
ZV850SB installation heights
35-3/8"
27-1/2"
605Dia150
*25-1/2" Recommended
36" Min.
This vent hood must be installed 24" min. to 30" max. above the
cooking surface; 25-1/2" is recommended to ensure that the
duct cover meets the ceiling. The cooking surface should be at
least 36" above the floor.
605Dia151
Recirculating
accessory
ZXR858C
ZXR858C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR859C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
ZXR8510C
professional hoods
8-1/4"
Duct
cover
accessory
ZX858SB
ZX858SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX859SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
ZX8510SB
Custom hood inser ts
38-1/4" for 9-ft. ceiling using
ZX859SB accessory
50-1/8" for 10-ft. ceiling using
ZX8510SB accessory
Actual
Possible hood
ceiling
installation
height
height*
7' 11"
24-1/2"
8' 0"
25-1/2"
8' 1"
25-1/2" to 26-1/2"
8' 2"
25-1/2" to 27-1/2"
8' 3"
25-1/2" to 28-1/2"
8' 4"
25-1/2" to 29-1/2"
8' 5"
30" 8' 6"
30" 8' 7"
30" 8' 8"
30" 8' 9"
30"
8' 10"
30"
8' 11"
30"
9' 0"
30"
9' 1"
30"
9' 2"
30"
9' 3"
30"
9' 4"
30"
9' 5"
30"
9' 6"
30"
9' 7"
30"
9' 8"
30"
9' 9"
30"
9' 10"
30"
9' 11"
30"
10' 0"
30"
*Based on 36" countertop height.
ZV850 duct cover dimensions
Vented
installation
A
ZV858SB
14-3/16"
ZX859SB
20-1/2"
ZX8510SB
26"
B
15-3/16"
22-1/2"
27-1/2"
Recirculating
installation
A
ZV858C
14-3/16"
ZX859C
21-7/8"
ZX8510C
26"
B
15"
22-1/2"
27-15/16"
te l e s c o p i c
d o w n d r a f t v e nt s
*Height
to Ceiling
chimney hoods
Advance planning for chimney hoods—island
9-7/16"
B
A
15-3/4"
The serial plate is located behind the removable filters.
69
Advance planning for chimney hoods—island
Product dimensions and clearances
Determine installation height
This glass canopy hood can be installed over any Monogram®
cooktop (except Professional models).
Use this chart to accurately determine installation heights,
depending on your ceiling heights.
Model ZV925SLSS
*The supplied duct
*Height
cover is sized to
to
fit 8' to 9' ceiling
Ceiling
heights.
For 9'1" to 10'1"
ceilings, order
ZX92510.
27 9/ 16"
3 1/4"
35 7/8"
NOTE: Measure
installation height
from the cooking
surface to the outer
glass portion of
the hood.
24" Min.
30" Max.
36" Min.
• This hood must be installed 24" min. and 30" max. above the
cooking surface. The cooking surface should be at least 36"
above the floor.
Important
• The hood installation height depends on the ceiling
height. Use the chart shown to determine the EXACT
installation height.
• Duct cover side trim pieces are provided and must be used
to cover installation screws. They are sized to fit the specific
installation heights shown in the chart.
• This hood can be installed for recirculating operation.
No kits required.
ZV925SLSS duct cover dimensions
14”
Side
Trim
Side
Trim
23-1/4”
NOTE: ZX92510 accessory
consists of one 36-3/4" long
duct cover.
24-3/4”
12-3/16”
The serial plate is located behind the removable filters.
70
ZV925 installation heights
Hood
Possible
installation
ceiling height height*
7' 11"
25"
8' 0"
27"
8' 1"
24"
8' 1"
28"
8' 2"
25"
8' 2"
29"
8' 3"
26"
8' 3"
30"
8' 4"
27"
8' 5"
24"
8' 5"
28"
8' 6"
25"
8' 6"
29"
8' 7"
26"
8' 7"
30"
8' 8"
27"
8' 9"
24"
8' 9"
28"
8' 10"
25"
8' 10"
29"
8' 11"
26"
8' 11"
30"
9' 0"
27"
ZV92510 accessory duct cover
9' 1"
24"
9' 1"
28"
9' 2"
25"
9' 2"
29"
9' 3"
26"
9' 3"
30"
9' 4"
27"
9' 5"
24"
9' 5"
28"
9' 6"
25"
9' 6"
29"
9' 7"
26"
9' 7"
30"
9' 8"
27"
9' 9"
24"
9' 9"
28"
9' 10"
25"
9' 10"
29"
9' 11"
26"
9' 11"
30"
10' 0"
27"
10' 1"
28"
*Based on 36" countertop height.
Mounting
frame
height
30-1/2"
30-1/2"
34-1/2"
30-1/2"
34-1/2"
30-1/2"
34-1/2"
30-1/2"
34-1/2"
38-1/2"
34-1/2"
38-1/2"
34-1/2"
38-1/2"
34-1/2"
38-1/2"
42-1/2"
38-1/2"
42-1/2"
38-1/2"
42-1/2"
38-1/2"
42-1/2"
Duct cover
accessory
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
46-1/2"
42-1/2"
46-1/2"
42-1/2"
46-1/2"
42-1/2"
46-1/2"
50-1/2"
46-1/2"
50-1/2"
46-1/2"
50-1/2"
46-1/2"
50-1/2"
54-1/2"
50-1/2"
54-1/2"
50-1/2"
54-1/2"
50-1/2"
54-1/2"
54-1/2"
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
ZX92510
monogram.com
Product dimensions and clearances
Using duct cover accessories
This stainless steel hood can be installed over any Monogram
cooktop or range, including professional models.
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
the need for a duct cover accessory.
Model ZV1050SFSS
*20" for 8-ft. ceiling using
supplied duct cover
ZV1050SFSS installation heights
*Height
to Ceiling
32" for 9-ft. ceiling using
ZX1059SFSS accessory
44" for 10-ft. ceiling using
ZX10510SFSS accessory
10"
This vent hood is supplied with a decorative duct cover to
reach 8-ft. ceiling height, or between 7' 11" and 8' 1".
605Dia153
*30"
Recommended
36" Min.
professional hoods
42"
Duct
cover
accessory
Supplied
Supplied
Supplied
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX1059SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
ZX10510SFSS
Custom hood inser ts
31-1/2"
Actual
Possible hood
ceiling
installation
height
height*
7' 11"
29"
8' 0"
30"
8' 1"
30"
8' 2"
25-1/2" to 30"
8' 3"
25-1/2" to 30"
8' 4"
25-1/2" to 30"
8' 5"
25-1/2" to 30"
8' 6"
25-1/2" to 30"
8' 7"
25-1/2" to 30"
8' 8"
25-1/2" to 30"
8' 9"
25-1/2" to 30"
8' 10"
25-1/2" to 30"
8' 11"
25-1/2" to 30"
9' 0"
25-1/2" to 30"
9' 1"
25-1/2" to 30"
9' 2"
25-1/2" to 30"
9' 3"
25-1/2" to 30"
9' 4"
25-1/2" to 30"
9' 5"
25-1/2" to 30"
9' 6"
25-1/2" to 30"
9' 7"
25-1/2" to 30"
9' 8"
25-1/2" to 30"
9' 9"
25-1/2" to 30"
9' 10"
25-1/2" to 30"
9' 11"
25-1/2" to 30"
10' 0"
25-1/2" to 30"
*Based on 36" countertop height.
chimney hoods
Advance planning for chimney hoods—island
*9-ft. to 10-ft. ceilings may be 25-1/2" to 30" clearance.
The distance between the cooking surface and the bottom of the
hood must be at least 25-1/2". The 30" recommended installation
height above the standard 36" countertop will ensure duct
cover fit to the ceiling. For 9-ft. and 10-ft. ceiling heights, the
hood may be lowered to 25-1/2" over the cooking surface.
ZV1050 duct cover dimensions
Model
Accessory
A
B
ZV1050
Supplied
11-1/2"
12"
ZV1050
ZX1059
19"
20"
ZV1050
ZX10510
25"
26"
te l e s c o p i c
d o w n d r a f t v e nt s
605Dia172
This vent hood must be installed 25 1/2" min. and 30" max. above
the cooking surface.
The serial plate is located behind the
removable filters.
• When installing this island hood above a Monogram
professional range or cooktop, installation clearance must
be at least 30".
Important: Clearances may vary due to type of cooking
product and local codes. Check with local inspectors to be
sure the standard is applicable.
71
Professional hoods
4 8", 36" and 30"
tapered-sided
hoods
ZV48TSFSS
48", 36" and 30"
straight-sided
hoods
ZV48SSFSS
54" and 42"
island hoods
ZV48RSFSS, ZV36RSFSS and
ZV30RSFSS
ZV48TSFSS, ZV36TSFSS and
ZV30TSFSS
ZV48SSFSS, ZV36SSFSS and
ZV30SSFSS
ZV54ISHSS and ZV42ISHSS
Overall dimensions
(WxHxD in inches):
48 x 22-1/2 x 25
36 x 22-1/2 x 25
30 x 22-1/2 x 25
Amps @ 110 Volts 12.4/6.4/6.4
Approx. shipping
wt. (lbs.)
130/110/100
Overall dimensions
(WxHxD in inches):
48 x 18 x 25
36 x 18 x 25
30 x 18 x 25
Amps @ 110 Volts 12.4/6.4/6.4
Approx. shipping
wt. (lbs.)
130/110/100
Overall dimensions
(WxHxD in inches):
48 x 18 x 25
36 x 18 x 25
30 x 18 x 25
Amps @ 110 Volts 12.4/6.4/6.4
Approx. shipping
wt. (lbs.)
130/110/100
Overall dimensions
(WxHxD in inches):
54 x 24 x 36-1/4
42 x 20 x 31-1/2
• 10" round exhaust duct
• Exhaust damper
• Snap-in blower assembly
• 6" and 12" standard or
full-width stackable duct
covers (order separately)
• Stainless steel backsplash
included
• Warming shelf included
• 10" round exhaust duct
• Exhaust damper
• Snap-in blower assembly
• 6" and 12" standard-width
stackable duct covers (order
separately)
• 10" round exhaust duct
• Exhaust damper
• Snap-in blower assembly
• 6" and 12" standard or
full-width stackable duct
covers (order separately)
• 10" round exhaust duct
• 8' ceiling duct cover and
support (included)
• Optional 9'-10' ceiling duct
cover and support available
4 8", 36" and 30"
restaurant-style hoods
ZV48RSFSS
General features
Professional styling. Crafted of premium-grade stainless steel, with every edge buffed by hand,
Monogram professional hoods make a compelling statement of quality and refinement.
Powerful ventilation. A powerful centrifugal blower, up to 1200 CFM, and variable-speed control
keep your kitchen free of fumes and excess heat.
Infrared warming lamps. Powerful infrared lamps on wall-mounted hoods cast a warm glow over
the cooking surface, while generating the heat necessary to keep baked goods at ready-to-serve
temperatures.
Brilliant task lighting. Halogen lights illuminate the cooktop surface below and can be adjusted to
complement the dining occasion.
Removable filters. During ventilation, stainless steel filters trap airborne grease particles, and can
be easily removed for safe cleaning in your dishwasher.
For additional details on product installation, warranty coverage, care and maintenance, visit
monogram.com.
72
Amps @ 120 Volts
Approx. shipping
wt. (lbs.)
10.4/9.5
210/170
monogram.com
Professional vent hoods
Ductwork planning
Restaurant-style, tapered- and straight-sided hoods
Select a professional hood with straight or tapered sides, or
a dramatic restaurant-style hood to match the width of the
range or cooktop. All professional hoods are available in 48",
36" and 30" widths.
Restaurant-style, tapered- and straight-sided hoods
These vent hoods are equipped for 10" round ductwork. For
best performance, use 10" round ductwork on the 48"-wide
hoods. 36" and 30" hoods may be transitioned to 8" round.
• Optional accessories must be ordered with the hood and be
on-site before final framing and wall finishing.
• A mounting template is provided with each hood to help
accurately locate the hood above the cooking surface and to
locate the mounting frame and screws.
• For a finished appearance, a top cover is supplied with both
hoods. Install the top cover whenever the top of the hood
will be visible.
Structural suppor t
Restaurant-style, tapered- and straight-sided hoods
All professional hoods weigh over 100 pounds; therefore
adequate structural support must be provided. Hoods
must be secured to vertical studs or to studs in the soffit.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on-site before final framing and wall
finishing. This will help to accurately locate the ductwork
and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop underneath.
Professional hoods
• Accessories are available to reach ceiling heights from
8' 6" to 10' 4". These accessories include telescoping support
frames and decorative covers.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• For satisfactory performance, duct run should not exceed
150 feet equivalent length for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Island hoods
These vent hoods are equipped for 10" round rigid metal duct.
Maximum equivalent duct length is 150 ft. Install a roof cap
with damper at the exterior opening.
Custom hood inser ts
Island hoods
Both models are shipped with a support frame and duct cover
for ceiling heights of 7' 11" up to 8' 5".
• Hoods may be vented vertically through upper cabinets,
soffit or ceiling. The blower outlet is 8-1/8" x 8". A duct
transition to 10" round with damper is supplied for vertical
exhaust. Use locally supplied elbows to vent horizontally.
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15 or 20 amp circuit breaker or time delay fuse.
• On wall-mounted hoods, the back side is recessed, providing
a large area for the house wiring to exit the wall and be routed
to the rear knockout and junction box.
• T he exact location for the house wiring depends on the
installation height and size of the hood. See installation
instructions for details.
te l e s c o p i c
d o w n d r a f t v e nt s
• All models can be installed onto a wall or beneath a soffit.
Decorative duct covers are available for all models. The duct
cover conceals the ductwork running from the top of the
hood to the ceiling or soffit. Duct covers are available in
6" or 12" heights. Stack one or more duct covers to reach
your ceiling height.
chimney hoods
Advance planning for professional hoods
• On wall-mounted hoods, the junction box is fastened to the
back of the hood on the right side. If necessary, the junction
box can be relocated to the top of the hood.
• On island hoods, the junction box is located on the top of the
hood and is concealed by ductwork.
Island hoods
These vent hoods are heavy. Adequate structural support
must be provided. The ceiling structure must be capable of
supporting the weight of the hoods and any inadvertent user
contact loads (approximately 300 lbs.).
73
Advance planning for professional hoods
Restaurant-style hood dimensions
Straight-sided hood dimensions
12"
12"
47-15/16"
10"
ZV48RSFSS
12"
ZV48SSFSS
18"
22-1/2"
12"
35-15/16"
605Dia138
10"
ZV36RSFSS
18"
22-1/2"
25"
12"
10"
29-15/16"
29-15/16"
25"
Tapered-sided hood dimensions
Island hood dimensions
605Dia136
16"
40"
33"
ZV48TSFSS
18"
25"
12"
24"
47-15/16"
28"
717Dia5
ZV30SSFSS
18"
29-15/16"
12"
ZV36SSFSS
35-15/16"
605Dia133
ZV30RSFSS
22-1/2"
605Dia140
605Dia132
12"
29-15/16"
25"
35-15/16"
25"
35-15/16"
605Dia139
47-15/16"
25"
47-15/16"
25"
47-15/16"
36-1/4"
ZV36TSFSS
Model ZV54ISHSS
supplied duct
cover dimensions:
20-1/4"W x 12"D
x 5"H
54"
18"
25"
12"
14"
35-15/16"
22"
717Dia6
25-3/4"
Model ZV42ISHSS
supplied duct
cover dimensions:
16"W x 12"D x 9"H
ZV30TSFSS
20"
18"
25"
74
29-15/16"
31-3/4"
42"
monogram.com
Advance planning for professional hoods
Restaurant-style hoods
Determine bottom of hood location by subtracting 12-1/2"
from the desired installation height.
Island hoods
These vent hoods must be installed 30" min. and 36" max.
above the cooking surface—regardless of ceiling height.
Therefore, installation height of the hood depends on the
exact ceiling height of the kitchen.
8 ft. Ceiling
Note: Exact installation height
is affected by the use of the
supplied warming shelf and
by the use of duct covers.
chimney hoods
Installation height requirements
8 ft. Ceiling
9" Supplied
Duct Cover
5" Supplied
Duct Cover
Dim. A
Restaurant-style hoods are supplied with a stainless steel
backsplash and a warming shelf. Install the hood with or
without either. Clearances to the cooking surface will vary
depending upon use of the warming shelf.
605Dia141
31"
31"
ZV42I
ZV54I
Professional hoods
Installation
Height
Example: Hood installation height with 8 ft. ceilings.
• If the ceiling height is 7' 11", the hood installation height
above the cooking surface will be 30".
• If the ceiling height is 8' 5", the hood installation height
above the cooking surface will be 36".
32" Min.
38" Max.
Installation without
warming shelf
Install these vent hoods
30" min. to 36" max. above
the cooking surface of any
Professional-style range or
cooktop.
Installation with supplied
warming shelf
Install the hood 32" min. to
38" max. above any type
cooking surface when the
warming shelf is used.
605Dia137
12" Duct Cover
6" Duct Cover
Hood
6" duct
cover
12" duct
cover
ZV48
ZX48DC6 ZX48DC12
ZV36, ZV30 ZX36DC6 ZX36DC12
If you are installing the hood above a gas or electric drop-in
style cooktop, the hoods may be installed as low as 24" above
the cooking surface.
Tapered- and straight-sided hoods
Install these vent hoods 30" min. to 36" max. above the
cooking surface of any professional range or cooktop. If you
intend to install the hood above a gas or electric drop-in style
cooktop, the hoods may be installed as low as 24" above the
cooking surface.
Note: Exact installation height
may be determined by use of
one or more duct covers.
Standard duct covers
Standard duct covers are for professional restaurant-style,
tapered- and straight-sided hoods. Available in 6" and 12"
heights, duct covers may be stacked in various combinations
to conceal the ductwork running from the top of the hood.
To avoid unsightly gaps above the hood, plan the hood
installation height with consideration to duct cover use.
te l e s c o p i c
d o w n d r a f t v e nt s
30" Min.
36" Max.
Custom hood inser ts
Duct cover accessories
Dimensions (in inches)
6H or 12H x 19-11/16W x 11-7/8D
6H or 12H x 15-3/4W x 11-7/8D
605Dia142
Full-width duct covers
Full-width duct covers are for professional restaurant-style and
straight-sided hoods only. Available in 6" and 12" heights, duct
covers span the full width of the hood and may be stacked
in various combinations. To avoid unsightly gaps above the
hood, plan the hood
installation height
with consideration to
duct cover use.
Optional 6"
or 12" Duct
Cover
30" MIN.
36" MAX.
6" duct
Hood cover
ZV48
ZV36
ZV30
12" duct
cover
Dimensions (in inches)
ZX48FWDC6 ZX48FWDC12 6H or 12H x 47-15/16W x 11-7/8D
ZX36FWDC6 ZX36FWDC12 6H or 12H x 35-15/16W x 11-7/8D
ZX30FWDC6 ZX30FWDC12 6H or 12H x 29-15/16W x 11-7/8D
75
Advance planning for professional hoods
Installation height requirements
Using duct cover accessories
Restaurant-style hoods
These vent hoods must be installed 30" min. to 36" max. above
the standard 36”-high cooking surface. When installed with
the warming shelf, allow 32" min. to 38" max. clearance. The
exact hood installation height is determined by the ceiling
height.
One or more duct cover accessories may be required for your
hood installation height. Use this chart to determine the size
and number of duct cover accessories required depending on
the use of the supplied warming shelf.
1. Measure the exact ceiling height.
2. Review the chart below to determine the range of hood
installation heights that can be accomplished with a 6”
or 12” duct cover accessory.
• Increase or decrease hood installation height to
accommodate the fixed 6” or 12” duct cover heights.
• Duct covers may be stacked, in various combinations,
to reach ceiling heights.
Duct Cover(s)
10" Hood
Height
Duct Cover(s)
10" Hood
Height
30" Min.
36" Max.
Ceiling
Height
to Floor
32" Min.
38" Max.
Ceiling
Height
to Floor
Note: When determining the installation height, consideration
must be given to the use of the warming shelf.
76
Restaurant-style hoods
without warming shelf
installed
Restaurant-style hoods
with warming shelf
installed
Possible Possible
Duct
Duct
Actual
hood
hood
cover
cover
ceiling
installation
installation
height
height*
6" 12" height*
6"
12"
7' 11"
31"
1
1
37"
1
8' 0"
32"
1
1
32"
1
1
8' 0"
38"
1
8' 1"
33"
1
1
33"
1
1
8' 2"
34"
1
1
34"
1
1
8' 3"
35"
1
1
35"
1
1
8' 4"
30"
2
8' 4"
36"
1
1
36"
1
1
8' 5"
31"
2
37"
1
1
8' 6"
32"
2
32"
2
8' 6"
38"
1
1
8' 7"
33"
2
33"
2
8' 8"
34"
2
34"
2
8' 9"
35"
2
35"
2
8' 10"
30"
1
2
8' 10"
36"
2
36"
2
8' 11"
31"
1
2
37"
2
9' 0"
32"
1
2
32"
1
2
9' 0"
38"
2
9' 1"
33"
1
2
33"
1
2
9' 2"
34"
1
2
34"
1
2
9' 3"
35"
1
2
35"
1
2
9' 4"
30"
3
9' 4"
36"
1
2
36"
1
2
9' 5"
31"
3
37"
1
2
9' 6"
32"
3
32"
3
9' 6"
38"
1
2
9' 7"
33"
3
33"
3
9' 8"
34"
3
34"
3
9' 9"
35"
3
35"
3
9' 10"
30"
1
3
9' 10"
36"
3
36"
3
9' 11"
31"
1
3
37"
3
10' 0"
32"
1
3
32"
1
3
10' 0"
38"
3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
monogram.com
Installation height requirements
Using duct cover accessories
Tapered- and straight-sided hoods
These vent hoods must be installed 30" min. to 36" max.
above the standard 36"-high cooking surface. The exact
hood installation height is determined by the ceiling height.
One or more duct cover accessories may be required
for your hood installation height. Use this chart to
determine the size, number or combination of duct cover
accessories required.
1. Measure the exact ceiling height.
Duct Covers
18" Hood
Height
Ceiling Height
to Floor
Installation Height
Professional hoods
• Duct covers may be stacked, in various combinations,
to reach ceiling heights.
Custom hood inser ts
• Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct cover heights.
Tapered- or
straight-sided Straight-sided
hoods with
hoods only standard with full-width
duct cover
duct cover
Duct
Duct
Actual
Possible hood
cover
cover
ceiling
installation
height
height*
6"
12"
6"
12"
7' 11"
35"
1
1
8' 0"
30"
1
1
8' 0"
36"
1
1
8' 1"
31"
1
1
8' 2"
32"
1
1
8' 3"
33"
1
1
8' 4"
34"
1
1
8' 5"
35"
1
1
8' 6"
30"
1
1
1
1
8' 6"
36"
1
1
8' 7"
31"
1
1
1
1
8' 8"
32"
1
1
1
1
8' 9"
33"
1
1
1
1
8' 10"
34"
1
1
1
1
8' 11"
35"
1
1
1
1
9' 0"
30"
2
2
9' 0"
36"
1
1
1
1
9' 1"
31"
2
2
9' 2"
32"
2
2
9' 3"
33"
2
2
9' 4"
34"
2
2
9' 5"
35"
2
2
9' 6"
30"
1
2
1
2
9' 6"
36"
2
2
9' 7"
31"
1
2
1
2
9' 8"
32"
1
2
1
2
9' 9"
33"
1
2
1
2
9' 10"
34"
1
2
1
2
9' 11"
35"
1
2
1
2
10' 0"
30"
3
3
10' 0"
36"
1
2
1
2
10' 1"
31"
3
3
10' 2"
32"
3
3
10' 3"
33"
3
3
10' 4"
34"
3
3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
te l e s c o p i c
d o w n d r a f t v e nt s
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with a 6" or
12" duct cover accessory.
chimney hoods
Advance planning for professional hoods
The serial plate is located behind the removable filters.
77
Advance planning for professional island hoods
Installation height requirements
Using duct cover accessories
These vent hoods must be installed 30" min. to 36" max.
above the standard 36"-high cooking surface. The exact
hood installation height is determined by the ceiling height.
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
the need for a duct cover accessory.
1. Measure the exact ceiling height.
Actual
ceiling
height
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with or
without an accessory kit.
Duct Cover
20" for ZV42I
24" for ZV54I
30" Min. and 36" Max.
Ceiling
Height
36"
to
Countertop
Accessory support frames with duct covers
ZX42DC10—Optional accessory for ZV42I, for use with ceiling
heights of 8' 6" to 10' 4". Kit includes telescoping support
frames and duct covers.
ZX54DC10—Optional accessory for ZV54I, for use with ceiling
heights of 8' 6" to 10' 4". Kit includes telescoping support
frames and duct covers.
Installation heights
ZV42 Possible hood
Duct
installation cover
height*
access.
7' 11"
30"
Supplied
8' 0"
31"
Supplied
8' 1"
32"
Supplied
8' 2"
33"
Supplied
8' 3"
34"
Supplied
8' 4"
35"
Supplied
8' 5"
36"
Supplied
8' 6"
30" to 31"
ZX42DC10
8' 7"
30" to 32"
ZX42DC10
8' 8"
30" to 33"
ZX42DC10
8' 9"
30" to 34"
ZX42DC10
8' 10"
30" to 35"
ZX42DC10
8' 11"
30" to 36"
ZX42DC10
9' 0"
30" to 36"
ZX42DC10
9' 1"
30" to 36"
ZX42DC10
9' 2"
30" to 36"
ZX42DC10
9' 3"
30" to 36"
ZX42DC10
9' 4"
30" to 36"
ZX42DC10
9' 5"
30" to 36"
ZX42DC10
9' 6"
30" to 36"
ZX42DC10
9' 7"
30" to 36"
ZX42DC10
9' 8"
30" to 36"
ZX42DC10
9' 9"
30" to 36"
ZX42DC10
9' 10"
30" to 36"
ZX42DC10
9' 11"
30" to 36"
ZX42DC10
10' 0"
30" to 36"
ZX42DC10
10' 1"
30" to 36"
ZX42DC10
10' 2"
30" to 36"
ZX42DC10
10' 3"
31" to 36"
ZX42DC10
10' 4"
32" to 36"
ZX42DC10
*Based on 36" countertop height.
Installation heights
ZV54
Possible
hood
Duct
installation
cover
height*
access.
30"
31"
32"
33"
34"
35"
36"
30"
30" to 31"
30" to 32"
30" to 33"
30" to 34"
30" to 35"
30" to 36"
30" to 31"
30" to 32"
30" to 33"
30" to 34"
30" to 35"
30" to 36"
30" to 36"
30" to 36"
30" to 36"
30" to 36"
31" to 36"
32" to 36"
33" to 36"
34" to 36"
35" to 36"
36"
The serial plate is located behind the removable filters.
78
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
Supplied
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
ZX54DC10
monogram.com
ZVC48
chimney hoods
Custom insert hoods
General features
Patented installation process. Exclusive design allows an easy
and secure connection with the ventilation duct from within
the unit, without any modification to the exterior canopy.
Halogen lighting. Four levels of clean, brilliant illumination suit
any cooking task.
Removable filters. Stainless steel mesh filters fit securely and
lift out easily for safe cleaning in the dishwasher.
Professional hoods
Complete with blower, liner and filters. No additional
components or accessory kits required.
ZVC48LSS
Overall dimensions
(WxD in inches): 39-1/2" x 14"
Amps @ 120VAC
10.05
Approx. shipping wt. (lbs.)
47
• Dual blowers
• 8" round exhaust duct
• Snap-in blower assembly
• May be mounted onto a wall
or in an island custom canopy
ZVC30 and ZVC36
Custom hood inser ts
Control with remote-mount option. At the time of installation,
the control can be detached from the insert for mounting on a
wall, countertop or other location. When positioned onboard,
the panel is angled downward to allow easy adjustment of
ventilation and light settings.
48" custom hood inser t
30" and 36" custom hood inser ts
ZVC30LSS
ZVC36LSS
Overall dimensions
(WxD in inches): 27-1/2" x 14"
Amps @ 120VAC
Approx. shipping wt. (lbs.)
te l e s c o p i c
d o w n d r a f t v e nt s
Powerful ventilation. Single- and dual-blower ventilation with
variable speed fan exhausts air at a rate of 640 and 1200 cubic
feet per minute, making the inserts compatible with highperformance cooking appliances.
5.34
30
• 8" round exhaust duct
• Snap-in blower assembly
• May be mounted onto a wall
or in an island custom canopy
79
Advance planning for custom hood inserts
These hood inserts are designed for easy installation into a
variety of custom hood applications. The hood attaches directly
to the house ducting from within the unit.
The supplied liner
• The custom canopy must be constructed to house the
insert sleeve.
• The sleeve has locking clips on the bottom edge to hold
it in place. The opening must be constructed of 3/4"-thick
material to allow the locking clips to engage.
A
width
ZVC30LSS 1-1/4"
ZVC36LSS 4-1/4"
ZVC48LSS 3-7/8"
• The opening must be sized accurately to accept the insert
sleeve and the supplied or custom liner.
• Always maintain the 1/2" dimension at the rear to ensure
correct alignment of the ductwork.
• If you are not using the supplied liner you may construct a
custom non-combustible liner. The custom liner must be
constructed to the dimensions shown to fit the insert sleeve.
• These hood inserts must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation instructions.
Refer to the installation instructions for details.
B
width
28-1/2"
34-1/2"
46-1/2"
Custom cabinet opening
width depth
ZVC30LSS
26" 13-3/16"
ZVC36LSS
26" 13-3/16"
ZVC48LSS 38-3/4" 13-3/16"
*Opening
*Custom cabinet
frame
cutout opening must
3/4" thick
material
be 26" W x 13-3/16" D for 30" and 36"
models and 38-3/4" W x 13-3/16" D for 48"
models. To support the weight of the insert
Custom
sleeve
and toinsert
allow forliner
the temporary
locking clips to engage, the minimum
Use the same
opening
cabinet dimensions
recommended
thickness
of the bottom
cabinet surface should be 3/4".
to construct a custom
liner. 3/4"-thick material must surround the opening. The 1/2"
dimension at the rear is necessary to ensure duct alignment.
Product dimensions and clearances
Model ZVC48
Models
ZVC30
and
ZVC36
ZVC30
and
ZVC36
ZVC48
39-1/2"
27-1/2"
14"
14"
ZVC48
ZVC30 and ZVC36
29-1/2"
16-3/4"
14"
14"
1/2"
7/8"
25-3/4"
38-1/2"
13"
1/2"
NOTE: Bottom edge of insert sleeve
has a 7/8" flange on each side and
The
of the
insert
a 1/2"bottom
flange onedge
both front
and
back. sleeve has a 7/8" wide flange on the
1/2"
1/2"
NOTE: 1/2" flange surrounds
outside edge of insert sleeve.
13"
1/2"
Note: 1/2" flange surround outside edge of insert sleeve.
sides and 1/2" wide flange on the front and back.
Remote location for the control
The control panel may be removed from the hood and installed
into a wall or countertop. A 30-ft. length of wire is supplied to
accommodate most installation. A blanking plate covers the
opening when the controls are removed.
The overall size of the control panel is 4-1/4" wide and 2-1/4" deep.
80
3-11/16”
1-11/16”
Control Cutout
We recommend that the cutout in granite or other hard surfaces
be made before the countertop is installed.
monogram.com
Telescopic downdraft vents
chimney hoods
General features
Powerful ventilation. A 3-1/4" x 10" rectangular duct and a
durable, stainless steel vent capture smoke and odors at the
cooking surface. A variable-speed fan blower exhausts the air
at a rate of 500 CFM.
30" telescopic
downdraf
t vent
682Dia23
ZVB36SHSS, ZVB36WHWW
and ZVB36BHBB
ZVB30SHSS and ZVB30BHBB
Overall dimensions
(WxHxD in inches):
36 x 8-1/2 x 2-1/8
Amps @ 120VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
30 x 8-1/2 x 2-1/8
Amps @ 120VAC
Approx. shipping wt. (lbs.)
682Dia23
5
62
• 3-1/4" x 10" rectangular duct
• Stainless steel vent body
• Indoor remote blower kit
• Outdoor remote blower kit
with cover
5
60
• 3-1/4" x 10" rectangular duct
• Stainless steel vent body
• Indoor remote blower kit
• Outdoor remote blower kit
with cover
Custom hood inser ts
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
36" telescopic
downdraf t vent
Important installation note: The installation of these
downdraft vents in combination with any Monogram®
cooktop requires an extra-deep countertop. The flat surface
of the countertop must be deep enough, front to back, to
accommodate the combined depth of the vent and cooktop
together. Additional clearances required by UL from the cutout
to the front edge of the countertop also vary by model and must
be considered. Be sure to review the downdraft vent installation
instructions carefully. These instructions provide exact cutout
and countertop area requirements for the installation of the
vent with each specific Monogram cooktop.
te l e s c o p i c
d o w n d r a f t v e nt s
Remote blower placement installation kit. To reduce noise
in the kitchen, an outdoor or indoor installation kit is offered
for remote blower placement.
Professional hoods
Removable filters. Filters can be easily removed for safe
cleaning in your dishwasher.
81
Advance planning for telescopic downdraft vents
These downdraft vent systems are ideal for island and
peninsula cooking centers because they retract nearly flush
with the countertop. They may be installed with any Monogram®
electric or gas cooktop except professional models.
Both the 36" and 30" models are equipped with a separate
raise/lower switch. The switch must be installed in a separate
location outside of the vent and cooktop cutout.
Separate raise/
lower switch
A
B
27"
30" models
36" models
A
30"
36"
B
28-1/2"
34"
682Dia21
2"
7-1/2" 2-1/4"
3-3/4"
Countertop requirements
Countertops must have a deep flat surface to accommodate
the cooktop and the vent. Countertops with a rolled edge and
backsplash may not provide the flat surface area required.
Base cabinet requirements
The base cabinet must be deep enough to accommodate the
minimum clearance to the front edge of the countertop, the
cooktop burner box and the vent.
Downdraft vent and cooktop cutout
The installation of these downdraft vents with any Monogram
cooktop requires careful consideration. For accurate planning,
review the individual dimension drawings for the combined
vent and Monogram cooktop installation.
682Dia23
8-1/2"
Lift
Before you begin you must:
3-1/8"
2. Check to be sure that the total countertop depth required
(including minimum cutout to front edge depth) allows
enough space for a backsplash.
6-1/4"
1. Review countertop dimension illustrations to be sure you will
have enough flat countertop surface depth.
3. Review the cabinet illustration. Check to be sure that the
interior cabinet depth will house the cooktop burner box,
the vent and the cutout clearance from the front.
10-1/2"
3-3/8"
7-1/8"
4. When countertop and cabinet depth present a problem,
review Creative Solutions on page 85.
5. Read this section completely to accurately plan the
installation location, clearances and ductwork
requirements.
682Dia24
With careful planning you can achieve a custom look with
minimal adjustments.
The serial plate is located on the blower assembly.
82
monogram.com
Creative solutions
Optional accessories
Against-the-wall installation
Move the base cabinet forward, 3" to 5". Filler panels or
complimentary moldings can be added to the exposed
cabinet sides.
JXRB67 Accessory for indoor remote location of the blower/
motor assembly. Use this kit when the blower and motor
assembly will be located outside of the cabinet, such as below
the cabinet floor. The assembly will fit between 16" floor joists.
Maintain Cutout Clearances
to Front Edge as Specified
chimney hoods
Advance planning for telescopic downdraft vents
JXBC67 Outdoor cover accessory for remote installation of the
blower/motor assembly on an outside wall.
Ductwork
Professional hoods
Prepare the ductwork to vent to the outdoors.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• The maximum permissible length for the duct run is 150 feet.
Base Sink
Island or peninsula installation
Use an extra-deep countertop. The countertop overhang at the
front can be adjusted to meet setback to cutout requirements.
605Dia159
• The downdraft blower system is designed to use 3-1/4" x 10"
duct. It can be transitioned to 6" round.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall cap and any transition needed
in advance.
Venting options
The downdraft vent is shipped with the discharge outlet
pointing straight down and can be changed to a left- or rightside discharge. For even more flexibility, the entire blower and
mounting plate can be adjusted 3-1/2" to the left or right sides.
Countertop Overhang per Cooktop
Clearances Must be Maintained
End
Panel
Base Sink
te l e s c o p i c
d o w n d r a f t v e nt s
Filler Panel
Base Cabinet
• Use metal ductwork only.
Custom hood inser ts
Filler Panel
Cover Panel
Decorative trim
When the cutout to front edge of the countertop
requirement is more than 2", add a bullnose trim to the
front edge of the countertop. The additional trim allows
the cooktop to be moved forward, providing additional
countertop depth and interior cabinet space.
Discharge Down
(As Supplied)
682Dia49
605Dia160
Trim
Add a Bullnose
Trim or Decorative
Molding to
Increase
Countertop
Depth and to
Maintain
Required
Clearance From
Front Edge
1-7/8"
DOWNDRAFT
VENT
Discharge Left
682Dia50
Discharge Right
83
682Dia51
Advance planning for telescopic downdraft vents
Electrical and gas locations
• Install a standard electrical outlet within
reach of the vent’s two-foot-long power cord.
Locate the outlet inside the cabinet on the
right side wall.
Do Not Locate Gas or Electrical
Connections Within Shaded Area
Plan the placement of the electrical
outlet and gas (if used) carefully. Gas
or electrical outlets cannot be located
on the back wall of the cabinet
because they may interfere with the
downdraft plenum.
29-1/2"
34" for 36" Models
28-1/2" for 30" Models
• If the vent is installed in combination with a
Monogram gas cooktop, it may operate from
the same 120V standard duplex outlet.
Electrical
Outlet
12" Above
Cabinet Floor
• If the vent is installed in combination with a
Monogram electric cooktop, the vent must
operate from a separate 120V outlet.
Cutouts and clearances
Identify the cutout illustration for the Monogram® cooktop model you are installing.
682Dia47
ZGU385 gas cooktops with 36" vent
2-1/2" to
Cutout
1-7/8"
3-3/8" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
ZGU385 Cooktop
3/8"
1/4" Overlap
3/8"
1/8" Gap
21-11/16"
Cutout
Depth
23-5/16"
Total Flat
Surface
Required
at Center
34" Cooktop and Vent Cutout
7/16" Cooktop Overlap
(1-1/4" at Center)
2-1/2" Min.
Clearance to Cutout
Front Edge
of Countertop
1"
Countertop cutout: Requires
23-5/16" flat countertop surface
and 24-1/2" total countertop depth.
12" Min. Cutout
to Side Walls
605Dia170
30-3/4"
1/8"
gap
3/8"
28-1/2" cooktop
and vent cutout
23-7/8"
total flat
surface
required
at center
7/16" cooktop overlap
(1-1/4" at center)
2-1/2" min. clearance
to cutout
Front edge
of countertop
2-7/8" min.
cooktop
cutout to
rear verticle
combustible
surface
zgu385_in_cabinet
1-7/8"
ZGU384 Cooktop
Countertop cutout: Requires
23-7/8" flat countertop surface and
24-7/8" total countertop depth.
12" min. cutout to
wall, both sides
3/4"
Thick
Support
Rail
20-3/8"
3/4"
DOWNDRAFT VENT
22-3/4" to Back Wall
22" to Support Rail
24-3/4"
ZGU36K gas cooktops with 36" vent
2-1/2" to
Cutout
21-3/4"
Cutout
Depth
34" Cooktop and Vent Cutout
13/16" Cooktop Overlap
(1-1/2" at Center)
Front Edge
of Countertop
84
2-1/2" Min.
Clearance to Cutout
1-7/8"
ZGU36 Cooktop
20-1/16"
1/4" Overlap
1/8" Gap
23-1/2" (SS)
23-3/8" (B,W)
Total Flat
Surface
Required
at Center
6" Min. Cutout
to Side Walls
Cabinet:
Requires 23" inside
cabinet depth. See
Creative Solutions,
install in an island or
move cabinet base
forward.
zgu384_in_cabinet
2-1/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
36"
Cabinet: Requires
22-11/16" inside
cabinet depth.
Remove rear
support rail.
24-3/4"
2-1/2" to
Cutout
2-3/4"
22-3/8"
cutout
depth
19-5/8"
cooktop
cutout
depth
DOWNDRAFT VENT
22-3/4" to Back Wall
22" to Support Rail
ZGU384 gas cooktops with 30" vent
3/8"
3/4"
Thick
Support
Rail
20-1/16"
36-3/4"
3/4"
Countertop cutout: Requires
23-3/8" (B,W) 23-1/2" (SS) flat
countertop surface. Requires
24-3/8" (B,W) and 24-1/2" (SS)
total countertop depth.
DOWNDRAFT VENT
22-3/4" to Back Wall
22" to Support Rail
24-3/4"
3/4"
Thick
Support
Rail
Cabinet: Requires
22-11/16" inside
cabinet depth.
Remove rear
support rail.
monogram.com
Advance planning for telescopic downdraft vents
2-1/2" to
Cutout
1-7/8"
36-1/8" (SS)
36" (Black)
ZHU36 Cooktop
19-7/8"
1/4" Overlap
23" (SS)
22-7/8" (Black)
Total Flat
Surface
Required
5/8" Cooktop Overlap
(1-1/32" at Center)
Front Edge
of Countertop
2-1/2" Min.
Clearance to Cutout
Countertop cutout: Requires
22-7/8" (Black) 23" (SS) flat
countertop surface. Requires
24-1/4" (Black) and 24-3/8"
(SS) total countertop depth.
24-3/4"
zhu36r_w_vent
zhu36r_cutout
ZHU30R induction cooktops with 30" vent
2-1/2" to
Cutout
1-3/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
29-7/8" (SS)
1/4" Overlap
29-3/4" (Black)
28-1/2"
Cooktop Area Cutout
5/8" Cooktop Overlap
(1-1/32" at Center)
2-1/2" Min.
Clearance to Cutout
Front Edge
of Countertop
Countertop cutout: Requires
23-3/8" (Black) 23-1/2" (SS)
flat countertop surface.
Requires 24-3/4" (Black)
and 24-7/8" (SS) total
countertop depth.
2-1/2" to
Cutout
36-1/8" (SS)
36" (B,W)
1/8" Gap
5/8" Cooktop Overlap
(1-1/8" at Center)
2-1/2" Min.
Clearance to Cutout
605Dia166
23" (SS)
22-7/8" (B,W)
Total Flat
Surface
Required
2" Min. Cutout
to Side Walls
1-7/8"
ZEU36 Cooktop
19-7/8"
1/4" Overlap
Front Edge
of Countertop
22-3/4" to Back Wall
22" to Support Rail
zhu30r_cutout
1-3/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
34"
Cooktop and Vent Cutout
Cabinet: Requires
23" inside cabinet
depth. See Creative
Solutions, install in
an island or move
cabinet base forward.
24-3/4"
ZEU36R digital cooktops with 36" vent
2-3/4"
3/4"
Thick
Support
Rail
DOWNDRAFT VENT
2" Min. Cutout
to Side Walls
zhu30r_w_vent
21-3/4"
Cutout
Depth 19-1/8"
Cooktop
Cutout
Depth
1-7/8"
ZHU30R Cooktop
20-3/8"
3/4"
1/8" Gap
22-3/8"
Cutout
Depth
22-3/4" to Back Wall
22" to Support Rail
2" Min. Cutout
to Side Walls
23-1/2" (SS)
23-3/8" (Black)
Total Flat
Surface
Required
at Center
Cabinet: Requires
22-1/2" inside cabinet
depth. Remove rear
support rail.
DOWNDRAFT VENT
3/4"
Countertop cutout: Requires
22-7/8" (B,W) 23" (SS) flat
countertop surface. Requires
24-1/4" (B,W) and 24-3/8" (SS)
total countertop depth.
te l e s c o p i c
d o w n d r a f t v e nt s
34"
Cooktop and Vent Cutout
Custom hood inser ts
1/8" Gap
2-3/4"
21-3/4"
Cutout
Depth 19-1/8"
Cooktop
Cutout
Depth
3/4"
Thick
Support
Rail
3/4"
Professional hoods
1-3/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
chimney hoods
ZHU36R induction cooktops with 36" vent
DOWNDRAFT VENT
3/4"
Thick
Support
Rail
Cabinet: Requires
22-1/2" inside cabinet
depth. Remove rear
support rail.
22-3/4" to Back Wall
22" to Support Rail
24-3/4"
605Dia167
85
Advance planning for telescopic downdraft vents
ZEU30R digital cooktops with 30" vent
2-1/2" to
Cutout
1-3/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
29-7/8" (SS)
1/4" Overlap
29-3/4" (B,W)
ZEU30 Cooktop
20-3/8"
3/4"
1/8" Gap
22-1/4"
Cutout
Depth
23-1/2" (SS)
23-3/8" (B,W)
Total Flat
Surface
Required
at Center
28-1/2"
Cooktop Area Cutout
5/8" Cooktop Overlap
(1-1/8" at Center)
Front Edge
of Countertop
2-1/2" Min.
Clearance to Cutout
Countertop cutout: Requires
23-3/8" (B,W) 23-1/2" (SS) flat
countertop surface. Requires
24-3/4" (B,W) and 24-7/8" (SS)
total countertop depth.
605Dia165
2-1/2" to
Cutout
1-3/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
22-1/2"
Total Flat
Surface
Required
34" Cooktop and Vent Cutout
5/8" Cooktop Overlap
2-1/2" Min. Clearance to Cutout
2" Min. Cutout
to Side Walls
1-7/8"
ZEU36 Cooktop
19-7/8"
1/4" Overlap
3/4"
1/8" Gap
Front Edge
of Countertop
22-3/4" to Back Wall
22" to Support Rail
Countertop cutout: Requires
22-1/2" flat countertop
surface and 24-3/8" total
countertop depth.
DOWNDRAFT VENT
22-3/4" to Back Wall
22" to Support Rail
24-3/4"
605Dia162
605Dia167
86
Cabinet: Requires
23" inside cabinet
depth. See Creative
Solutions, install in
an island or move
cabinet base forward.
24-3/4"
ZEU36K electric cooktops with 36" vent
36"
3/4"
Thick
Support
Rail
DOWNDRAFT VENT
2" Min. Cutout
to Side Walls
605Dia164
21-3/4"
Cutout
Depth
1-7/8"
3/4"
Thick
Support
Rail
Cabinet: Requires
22-1/2" inside
cabinet depth.
Remove rear
support rail.
monogram.com
General features
2
1
4
7
trive ct ion ® wall oven s
Electronic wall ovens with Trivection ® technology
3
5
6
8
9
0
LOWER OVEN
UPPER OVEN
LOCK
CLEAR
OFF
OVEN
LIGHT
TIMER
ON / OFF
OVEN
LIGHT
CLEAR
OFF
Sophisticated styling. Sleek, modern design provides a striking
look with clean lines and smooth, glass touch controls.
Cooking versatility. In addition to Trivection technology, these
ovens offer several other cooking methods and modes: baking,
broiling, roasting and true European convection, as well as
24-hour delay bake, warm mode and proof mode.
Full-size oven capacity. The spacious oven interior makes room
for foods ranging from large roasts to rich, multi-tiered cake pans
and everything in between.
Halogen lighting. Two halogen lights illuminate your culinary
work in progress.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
2
1
4
7
3
5
6
8
9
0
ZET3058SHSS
30" double oven with
Trivection technology
LOWER OVEN
UPPER OVEN
LOCK
CLEAR
OFF
OVEN
LIGHT
TIMER
ON / OFF
CLEAR
OFF
OVEN
LIGHT
ZET3038SHSS
30" single
oven with
Trivection technology
ZET3058SHSS and ZET3058BHBB
ZET3038SHSS and ZET3038BHBB
Overall dimensions
(WxHxD in inches):
29-3/4 x 52-7/8 x 23-1/2
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
29-3/4 x 28-1/4 x 23-1/2
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
37.1
32.2
333
• Flush appearance installation
• Fits standard 30"-wide
wall oven cabinets
Advance planning for electronic wall
ovens with Trivection technology
convection wall ove n s
Award-winning Trivection technology. Thermal, convection
and microwave cooking processes work together to produce
the ideal blend of taste and texture. Foods are prepared to
delectable perfection—on average up to five times faster
than a conventional oven.
24.6
21.2
199
• Flush appearance installation
• Fits standard 30"-wide
wall oven cabinets
• Undercounter installation
Electrical requirements
Product rating is 120/208 or 120/240V, 60Hz. Connect to a
40-amp circuit for double ovens and 30-amp circuit for single
ovens. The ovens must be connected to a supply circuit of the
proper voltage and frequency and protected by a time-delay
fuse or circuit breaker.
Cutout and product dimensions
10-1/2"
27-1/4" Min.
27-5/16" Max.
23-1/2"
7"
23-1/2"
Locate Junction Box 25" Min to
32" Max Above Cutout Floor,
Within 7" of Right Rear Wall
Locate Junction Box 12" Min to
18" Max Above Cutout Floor,
Within 3-1/2" to 10-1/2" of
Left Rear Wall
28-1/2" Min.
28-5/8" Max.
28-1/4"
51-13/16"
Min.
51-15/16"
Max.
28-1/2" Min.
28-5/8" Max.
52-7/8"
29-3/4"
32-1/2"
12"
30"
Note: These ovens are not approved for stackable or
side-by-side installations.
30"
29-3/4"
Note: Most 30" wall cabinets can be used with this unit. The
opening between the inside walls must be at least 28-1/2" wide.
87
Integrated LCD touchscreen, electronic dial and professional convection wall ovens
Wall oven general features
Integrated styling. (R and S models) Smooth, seamless exterior
with tubular handle, electronic dial controls and expansive
viewing window makes an unmistakable statement of quality
and refinement.
Professional styling. Sculptural lines, chamfered edges and
robust, die-cast electronic dial controls give depth and dimension
to the premium-grade stainless steel surface.
Exclusive self-clean, full-extension oven racks. Racks glide in
and out on stainless-steel ball bearings for easy access. The
adjustable, heavy-duty, porcelain-coated racks can remain in
the oven during the self-clean cycle.
Halogen light columns. Two brilliantly illuminated columns on
both sides of the oven enhance visibility, providing a clear view
of food regardless of rack position.
Reverse-Air convection system. Dedicated convection elements
and a bidirectional fan provide consistent temperature
throughout the oven.
30" LCD touchscreen
single oven
ZET1RMSS
ZET1RMSS
30" LCD touchscreen
double oven
ZET2RMSS
ZET2RMSS
• LCD touchscreen with
proximity sensor
• Flush appearance installation
• Fits standard 30"-wide wall
oven cabinets
• Approved for installation
over warming drawers
Six-element design. Two bake, two broil and two convection
elements provide precise cooking control, with fast preheating.
And, an electronic, low-voltage compensation feature boosts
power in 208V applications.
TIMER
CLOCK
COOK
TIME
PROBE
DELAY
START
CLOCK
COOK
TIME
DELAY
START
ZET1SMSS
ZET1SMSS
30" integrated
double oven
ZET2SMSS
ZET2SMSS
35.8
37.5
370
TIMER
30" integrated
single oven
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
Overall dimensions
(WxHxD in inches):
29-3/4 x 52-7/8 x 23-1/2
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
PUSH
TO
ENTER
PUSH
TO
ENTER
PROBE
4.4-cu.-ft total capacity. Generously sized interior accommodates
even the largest meals, and true hidden bake elements add
flexibility by allowing easy ash removal after the self-clean cycle.
Double oven
• LCD touchscreen with
proximity sensor
• Fits standard 30"-wide wall
oven cabinets
• Undercounter installation
• Undercooktop installation
• Approved for installation
under specified cooktops,
Advantium® ovens and over
warming drawers
• Approved for side-by-side
installation
• Flush appearance installation
• Fits standard 30"-wide wall
oven cabinets
• Approved for installation over
warming drawers
• Flush appearance installation
• Fits standard 30"-wide wall
oven cabinets
• Undercounter installation
• Under cooktop installation
• Approved for installation
under specified cooktops,
Advantium ovens and over
warming drawers
• Approved for side-by-side
installation
PUSH
TO
ENTER
PUSH
TO
ENTER
F
PROBE
TIMER
CLOCK
COOK
TIME
PROBE
TIMER
CLOCK
COOK
TIME
Single oven
Overall dimensions
(WxHxD in inches):
29-3/4 x 28-1/4 x 23-1/2
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
30" professional
single oven
ZET1PMSS
17.9
18.7
195
ZET1PMSS
30" professional
double oven
ZET2PMSS
ZET2PMSS
88
• Professional aesthetic
• Fits standard 30"-wide wall
oven cabinets
• Approved for installation over
warming drawers
• Professional aesthetic
• Fits standard 30"-wide wall
oven cabinets
• Undercounter installation
• Under cooktop installation
• Approved for installation
under specific cooktops,
Advantium ovens and over
warming drawers
• Approved for side-by-side
installation
monogram.com
Cutout and product dimensions
23-1/2"
Min.
The Integrated ovens offer contemporary styling with the
signature Monogram® tubular handles. The professional oven
design combines rugged stainless steel construction with refined
styling. Both are designed to fit into a 30"-wide cabinet.
Electrical requirements
Product rating is 120/208 or 120/240V, 60Hz. Connect to a
40-amp circuit for double ovens and 20-amp circuit for single
ovens. The ovens must be connected to a supply circuit of the
proper voltage and frequency and protected by a time-delay
fuse or circuit breaker.
Installation below a countertop
A single oven can be installed beneath countertops and below
approved cooktops. Always refer to the cooktop installation
instructions for electrical requirements and clearances.
1-1/2" Cabinet Top
25"
Locate Junction Box Within
5" of the Right Rear Wall
Locate Junction Box 47"
Above Cutout Floor, Within 5"
of Right Rear Wall
51-13/16"
Min.
51-15/16"
Max.
12"
30"
23-1/4"
Recessed
Depth
29-3/4"
Integrated double oven
ZET2SMSS Stainless steel
Professional double oven
ZET2PMSS Stainless steel
23-1/2"
Min.
27-1/4" Min.
27-5/16" Max.
23-1/2" Min.
52-7/8"
LCD touchscreen double oven
ZET2RMSS Stainless steel
36"
Countertop
Height
28-1/2" Min.
28-5/8" Max.
28-1/2" Min.
28-5/8" Max.
Locate Junction Box 22"
Above Cutout Floor, Within 5"
of Right Rear Wall
27-1/4" Min. 28-1/2" Min.
28-5/8" Max.
27-5/16" Max.
28-1/4"
Elevate the oven floor to desired height.
The support must be level, rigidly mounted
and capable of supporting 175 lbs.
23-1/4"
Recessed
Depth
32-1/2"
625Dia9
2″ (5.1 cm)
Min.
29-3/4"
30"
Side-by-side installations
Install two ovens in separate cutouts. Allow 2" minimum
between the cutouts.
Cutout –
Observe all
dimensions
and
requirements.
convection wall ove n s
The LCD touchscreen ovens with proximity sensor provide easy,
intuitive access to oven functions and options
trive ct ion ® wall oven s
Advance planning for LCD touchscreen, integrated
and professional convection wall ovens
Cutout –
Observe all
dimensions
and
requirements.
LCD touchscreen single oven
ZET1RMSS Stainless steel
Integrated single oven
ZET1SMSS Stainless steel
Professional single oven
ZET1PMSS Stainless steel
89
Electronic convection wall ovens
General features
LOWER OVEN
BAKE
ROASt
cONV
DELAY
StARt
StARt
1 RAcK
cOOK
tIME
MULt
BAKE
BROIL
WARM
PROOF
PROBE
SELF
cLEAN
cLEAR
OFF
cONV
cONV
HIGH
LOW
BAKE
BAKE
cONV
StARt
ROASt
1 RAcK
DELAY
StARt
cOOK
tIME
MULt
cLEAR
OFF
BAKE
BROIL
WARM
PROOF
PROBE
SELF
cLEAN
cONV
UPPER OVEN
BAKE
StD
LOW
2
1
3
4
5
6
7
cONV
HIGH
LOW
StD
LOW
tIMER
0
9
8
HIGH
LOW
LOcK
LOWER OVEN
Sophisticated styling. Seamless, hand-finished doors
and smooth controls offer a look of modern refinement.
BAKE
ROAST
CONV
DELAY
START
START
1 RACK
COOK
TIME
MULT
BAKE
BROIL
WARM
PROOF
PROBE
SELF
CLEAN
CLEAR
OFF
CONV
CONV
HIGH
LOW
BAKE
BAKE
CONV
START
ROAST
COOK
TIME
1 RACK
DELAY
START
MULT
CLEAR
OFF
BAKE
BROIL
WARM
PROOF
PROBE
SELF
CLEAN
CONV
UPPER OVEN
BAKE
STD
LOW
1
2
3
6
5
4
7
8
0
9
CONV
HIGH
LOW
STD
LOW
TIMER
HIGH
LOW
LOCK
Electronic glass touch controls. A gentle touch allows you
to easily select the desired cooking function: convection
bake or roast, variable or closed-door broiling, 24-hour
delay bake, warm mode or proof mode.
Reverse-Air convection. A bi-directional fan delivers
exceptionally consistent cooking performance, allowing
heated air to circulate on all sides of food.
Self-clean racks. Porcelain-coated racks are designed
to be left in the oven during the self-clean cycle for
effortless cleaning.
Halogen lighting. Two halogen lights illuminate your culinary
work in progress, putting it into bright, clear perspective.
Concealed bake element. A smooth surface simplifies
ash removal after the self-clean cycle.
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
ZEt958SMSS oven
30" double
27" double
oven
ZEK958SMSS
ZET958SMSS, ZET958WMWW and
ZET958BMBB
ZEK958SMSS and ZEK958BMBB
Overall dimensions
(WxHxD in inches):
29-3/4 x 52-7/8 x 23-1/4
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
26-5/8 x 51 x 23-1/4
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
37.5
32.6
260
• Flush appearance installation
• Fits standard 30"-wide
wall oven cabinets
• Approved for installation over
warming drawers
• Flush appearance installation
• Fits standard 27"-wide
wall oven cabinets
• Approved for installation over
warming drawers
OPTIONS
OPTIONS
OVEN
OVEN
DELAY
START
CONV
BAKE
MULT
CONV
BAKE
1 RACK
BROIL
BAKE
HIGH
LOW
CONV
ROAST
START
WARM
PROOF
CLEAR
OFF
DELAY
START
PROBE
2
3
4
5
6
7
8
0
9
SELF
CLEAN
STD
LOW
TIMER
ON
OFF
CONV
CONV
BAKE
BAKE
ROAST
START
MULT
1 RACK
BAKE
BROIL
WARM
PROOF
CLEAR
OFF
CONV
COOK
TIME
1
HIGH
LOW
COOK
TIME
1
2
3
4
5
6
7
8
0
9
PROBE
SELF
CLEAN
STD
LOW
TIMER
ON
OFF
LOCK
LOCK
30" single oven
27" single
ZEK938SMSSoven
ZET938SMSS, ZET938WMWW and
ZET938BMBB
ZEK938SMSS and ZEK938BMBB
Overall dimensions
(WxHxD in inches):
29-3/4 x 28-1/4 x 23-1/4
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
Overall dimensions
(WxHxD in inches):
26-5/8 x 29 x 23-1/4
Amps @240VAC
208VAC
Approx. shipping wt. (lbs.)
ZET938SMSS
19
16
135
• Flush appearance installation
• Fits standard 30"-wide
wall oven cabinets
• Undercounter installation
• Approved for installation under
specified cooktops, under
Advantium® ovens and over
warming drawers
• Approved for side-by-side
installation
90
28
25
164
15
13
100
• Flush appearance installation
• Fits standard 27"-wide
wall oven cabinets
• Undercounter installation
• Approved for installation under
specified cooktops, under
Advantium ovens and over
warming drawers
monogram.com
trive ct ion ® wall oven s
Advance planning for electronic convection wall ovens
Electrical requirements
Product rating is 120/208 or 120/240V, 60Hz. Connect to a
40-amp circuit for double ovens and 20-amp circuit for single
ovens. The ovens must be connected to a supply circuit of the
proper voltage and frequency and protected by a time-delay
fuse or circuit breaker.
Cutout and product dimensions
23-1/2"
10"
Locate Electrical Outlet Within 10"
of Left Side of Opening and 44" Above
Cutout Floor or 5" Below Cutout Floor
Locate Junction Box 47"
Above Cutout Floor, Within 5"
of Right Rear Wall
51-13/16"
Min.
51-15/16"
Max.
28-1/2" Min.
28-5/8" Max.
12"
52-7/8"
49-11/16"
Min.
50-1/8"
Max.
13-1/4"
30"
30" double ovens
ZET958SMSS Stainless steel
ZET958BMBB Black
ZET958WMWW White
23-1/4"
Recessed
Depth
29-3/4"
27-1/4" Min.
27-5/16" Max.
28-1/4"
23-1/4"
Recessed
Depth
32-1/2"
23-1/4"
Recessed
Depth
26-5/8"
23-1/2"
Min.
27-5/8" Min.
28-1/8" Max.
Locate Electrical Outlet Within 10"
of Left Side of Opening 22" Above
Cutout Floor or 5" Below Cutout Floor
25" Min.
25-1/4" Max.
29"
23-1/4"
Recessed
Depth
32-1/2"
26-5/8"
27"
30" single ovens
ZET938SMSS Stainless steel
ZET938BMBB Black
ZET938WMWW White
27" single ovens
ZEK938SMSS Stainless steel
ZEK938BMBB Black
605Dia92
30" single oven
side-by-side installations
Install two ovens in separate cutouts. Allow 2" minimum
between the cutouts.
2″ (5.1 cm)
Min.
27"
29-3/4"
30"
Cutout –
Observe all
dimensions
and
requirements.
51"
605Dia93
Locate Junction Box 22"
Above Cutout Floor, Within 5"
of Right Rear Wall
28-1/2" Min.
28-5/8" Max.
25" Min.
25-1/4" Max.
27" double ovens
ZEK958SMSS Stainless steel
ZEK958BMBB Black
605Dia91
23-1/2"
convection wall ove n s
23-1/2"
605Dia94
Cutout –
Observe all
dimensions
and
requirements.
91
Advance planning for built-in cooking products
Monogram built-in ovens and warming drawers are designed for installation flexibility and to coordinate with and
complement other Monogram appliances. Single ovens can also be installed below approved Monogram cooktops.
Review the following chart for approved combinations.
Approved single oven and cooktop installation combinations
30" integrated
ZET1S and ZET1R
30" professional
ZET1P
30" touch
ZET938
30" Trivection®
ZET3038
Gas cooktops
30" stainless steel ZGU384
•
•
•
36" stainless steel ZGU385
•
•
•
36" gas-on-glass ZGU36K
•
•
•
Induction cooktops
30" induction ZHU30
•
•
•
36" induction ZHU36
•
•
•
Electric cooktops
30" digital ZEU30R
•
•
36" digital ZEU36R
•
•
•
36" electric ZEU36K
•
•
•
Note: Built-in wall ovens with Advantium® Speedcook technology cannot be installed below a countertop.
The Trivection oven cannot be installed below a cooktop, but it may be installed below a countertop.
92
Warming drawer
ZTD/ZKD910
•
•
•
•
•
•
monogram.com
advantium ® Speedcook
wa ll oven
Wall oven with Advantium ® Speedcook technology
General features
SPEED
COOK
POWER
LEVEL
TIMER
MICRO
WAVE
MANUAL
COOK
OPTIONS
HELP
MICRO
EXPRESS
REPEAT LAST
TU
R N T O SE
START
PAUSE
BACK
RECIPE
PR
E
R
Sophisticated styling. The overall look is sleek. The oven’s
bold, horizontal lines are set off by simple graphics and a
tubular handle on the pull-down door.
CLEAR
OFF
ES S T O E N T
Speedcook technology. 4500-watt halogen cooking system
uses heat generated from light to rapidly cook the outside
of foods, sealing in natural juices. At the same time, heat
penetrates the surface, evenly cooking the inside.
Easy-to-use controls. The control dial smoothly turns in
both directions, making it easy to select from more than 100
preprogrammed recipes. For added convenience, Demo and
Help programs guide you through the simple process of
choosing a programmed recipe or customizing your own.
Full-function microwave oven. At the touch of a button, the oven
converts to a high-performance, sensor-controlled microwave.
Advantium
ZSC2001FWW/BB
Speedcook oven
microwave ove n s
Powerful performance. Oven-quality foods cook in up
to eight times faster than a conventional oven, with no
preheating required.
ZSC2001FSS, ZSC2000FWW
and ZSC2000FBB
Overall exterior dimensions
(excluding handles)
(WxHxD in inches):
29-25/32 x 21-7/8 x 15-27/32
Amps @240VAC
26.3
208VAC
22.7
Approx. shipping wt. (lbs.)
101
warming drawer s
• 30" oven cabinet width required
• Approved for installation
above a single wall oven
or warming drawer
Wall oven with Advantium 120 Speedcook technology
General features
Sophisticated styling. Clean lines offer a stylish, modern
look that coordinates beautifully with other Monogram®
built-in cooking products.
OVEN
MICROWAVE
SPEED
COOK
BAKE
BROIL
COOK
EXPRESS
FAVORITE
RECIPES
CUSTOM
WARM
PROOF
DEFROST
REHEAT
TIMER
SPEED
COOK
START
PAUSE
CLEAR
OFF
BACK
HELP
POWER
TEMP
OPTIONS
Remarkable versatility. Multiple cooking options create four
ovens in one—Speedcook, true European convection, sensor
microwave and warming ovens—to bake, broil, brown, roast,
warm and proof foods.
Spacious interior. Rounded oven cavity and 16" turntable
allow full and continual rotation of a 9" x 13" casserole
dish. Removable oven rack offers the convenience of
multi-level cooking.
Installation flexibility. Ovens can be installed in a 27" or
30" wall cabinet (with included trim kit).
ZSC1001JSS
Advantium
120
Speedcook oven
ZSC1001KSS and ZSC1000KBB
Overall exterior dimensions
(excluding handles)
(WxHxD in inches):
26-3/4 x 18-5/8 x 21-1/2
(27" cabinet)
29-3/4 x 18-5/8 x 21-1/2
(30" cabinet)
Amps @120V
13.8
Approx. shipping wt. (lbs.)
100
• Installs in 30" or 27" wall oven
cabinet, no kit required
• Approved for installation
above a single wall oven
or warming drawer
Dual -burn er
out d oor c ookt op
Powerful performance. Oven-quality foods cook up to
four times faster than a conventional oven, with no
preheating required.
3 6" out doo r
c ook ing cent e r s
Speedcook technology. Halogen-light system speedcooks
your favorite foods to delicious perfection—in minutes,
with no preheating.
93
Advance planning for wall oven with Advantium ® 240
Speedcook technology
The Monogram® Advantium built-in oven can be installed directly
into a wall, 30"-wide wall oven cabinetry. Install it alone, with a
single oven or with a warming drawer. Create a complete
cooking center by installing the Advantium with both.
• This oven must be installed at least 36-3/4" above the floor.
• For personal safety, this oven cannot be installed in a cabinet
arrangement such as an island or peninsula.
• This oven is not approved for installation below a countertop,
side by side or stacked.
Electrical requirements
Product rating is 120/208 or 120/240V, 60Hz, 30 amps. This product
must be connected to a supply circuit of the proper voltage and
frequency and protected by a time-delay fuse or circuit breaker.
Advantium 240 oven installed above a Monogram single
wall oven
When installed over a single oven or a warming drawer, allow at
least 2" between the two openings. This separation will provide
clearance for bottom overlap of the Advantium oven and top
overlap of the single oven or warming drawer.
• The Advantium oven and single oven combination can use
separate electrical junction boxes or a single junction box
connected to a 50-amp circuit.
30"
*The middle rail
separating the
two openings
may need to be
larger than the
2" min. shown.
24"
Min.
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
28-1/2"
21"
2" Min.
Per Oven
Requirement
Cutout and product dimensions
*45-1/4"
Advantium 240 oven installed alone
Order a 30"-wide single oven cabinet or cut the opening in
a wall to the dimensions shown.
30"
19"
Min
28-7/16"
28-1/2"
Advantium 240 oven installed above a Monogram single wall
oven and a warming drawer
An anti-tip block must be installed at the rear of the warming
drawer opening. See installation instructions for complete details.
605Dia87
15"
(Recessed
Portion)
21"
21-7/8"
15-27/32"
29-25/32"
• The Advantium oven and single oven combination can use
separate electrical junction boxes or a single junction box
connected to a 50-amp circuit.
• The warming drawer must be supplied with a separate
120V, 60Hz, properly grounded receptacle.
36-3/4" Min.
Required
Advantium 240 oven installed above a Monogram
warming drawer
An anti-tip block must be installed at the rear of the
warming drawer opening. Again, see installation
instructions for complete details.
605Dia85
• The warming drawer must be supplied with a separate
120V, 60Hz, properly grounded receptacle.
Note:
Additional
clearance
between
cutouts
may be
required.
30"
28-1/2"
21"
9-1/4"
36-3/4"
Min.
94
24"
Min.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
2" Min.
Install 2 x 4
or 2 x 2
Runners or
Solid Bottom,
Must Support
100 lbs.
605Dia86
Note: Additional
clearance between
cutouts may be
required. Check to
be sure the oven
supports above the
warming drawer
location do not
obstruct the required
interior 23-1/2" depth
and 9-1/4" height. See
each specific product’s
installation instructions
for details.
30"
21"
24"
Min.
28-1/2"
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
2" Min.
Per Oven
Requirement
2" Min.
45-1/4"
9-1/4"
605Dia112
monogram.com
• For personal safety, this oven cannot be installed in a cabinet
arrangement such as an island or peninsula.
• This oven is not approved for installation below a
countertop, side by side or stacked.
• The Advantium 120 oven and single oven combination
must be supplied with separate electrical connections.
27" or 30"
Electrical requirements
Product rating is 120 volt, 60 Hz, 15 amp circuit and draws 1.8
kilowatts. It must be connected to a supply circuit of the proper
voltage and frequency and protected by a time-delay fuse or
circuit breaker.
T he middle rail
separating the two
openings may need
to be larger than the
2" min. shown.
23-1/2"
25-1/8" Min.
25-1/4" Max.
17-1/2"
Advantium 120 oven installed alone
Order a 27" or 30"-wide single oven cabinet or cut the opening
in a wall to the dimensions shown.
warming drawer s
21-1/2"
17-1/2"
45-1/4"
Advantium 120 oven installed above a Monogram
single wall oven and a warming drawer
An anti-tip block must be installed at the rear of the warming
drawer opening. See installation instructions for complete details.
23-1/2"
25-1/8" Min.
25-1/4" Max.
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
2" Min.
Per Oven
Requirement
Cutout and product dimensions
27" or 30"
microwave ove n s
• This oven must be installed at least 36-3/4" above the floor.
Advantium 120 oven installed above a Monogram
single wall oven
When installed over a single oven or a warming drawer, allow at
least 2" between the two openings. This separation will provide
clearance for bottom overlap of the Advantium oven and top
overlap of the single oven or warming drawer.
• The warming drawer and the Advantium 120 oven must be
supplied with separate 120V, 60Hz, properly grounded receptacles.
18-5/8"
6"
Locate Outlet Box in
the Shaded Area
26-3/4"
36-3/4"
Min.
18-5/8"
Construct Base
Min. 3/8" Plywood
Supported by 2 x 4 or
1 x 2 Runners
all Four Sides
29-3/4"
with side trim
Advantium 120 oven installed above a Monogram
warming drawer
An anti-tip block must be installed at the rear of the
warming drawer opening. Again, see installation
instructions for complete details.
• The warming drawer must be supplied with a separate
120V, 60Hz, properly grounded receptacle.
27" or 30"
T he middle rail
separating the
two openings
may need to be
larger than the 2"
min. shown.
23-1/2"
25-1/8" Min.
25-1/4" Max.
17-1/2"
9-1/4"
36-3/4"
Min.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
2" Min.
Install 2 x 4
or 2 x 2
Runners or
Solid Bottom,
Must Support
100 lbs.
Note: Additional
clearance between
cutouts may be
required. Check to
be sure the oven
supports above the
warming drawer
location do not
obstruct the required
interior depth and
height. See each
specific product’s
installation instructions
for details.
27" or 30"
25-1/8" Min.
25-1/4" Max.
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
17-1/2"
2" Min.
Per Oven
Requirement
2" Min.
45-1/4"
Electrical location
Locate a recessed outlet within
6" of either side and at least 9"
above the cutout floor.
The serial plate is located
on the oven cavity flange,
behind the door.
23-1/2"
3 6" out doo r
c ook ing cent e r s
9"
9-1/4"
27" or 30"
23-1/2"
25-1/8" Min.
25-1/4" Max.
17-1/2"
6"
9"
Locate Outlet Box in
the Shaded Area
36-3/4"
Min.
Dual -burn er
out d oor c ookt op
The Monogram Advantium 120 built-in oven can be installed
directly into a wall, a 27"-wide or 30"-wide wall oven cabinetry.
Install it alone, with a wall oven or with a warming drawer.
advantium ® Speedcook
wa ll oven
Advance planning for wall oven with Advantium 120
Speedcook technology
Construct Base
Min. 3/8" Plywood
Supported by 2 x 4 or
1 x 2 Runners
all Four Sides
95
26-3
wit
Microwave ovens
MICROWAVE
CONVECTION
SENSOR
POPCORN
SENSOR
REHEAT
AUTO
DEFROST
MICRO
COOK
COMBINATION
SENSOR
BEVERAGE
SENSOR
COOK
TIME
DEFROST
TEMP
COMBINATION
COOK/HOLD
ROAST
PROBE
PROBE
SELECTIONS
1
COOK
2
3
4
EXPRESS
COOK
EXPRESS
COOK
EXPRESS
COOK
EXPRESS
COOK
6
7
8
9
COOK
5
EXPRESS
COOK
0
DISPLAY
ON/OFF
POWER
LEVEL
DELAY
START
START
ADD
30 SEC
MINUTE
CLEAR
OFF
REMINDER
LEVEL
KITCHEN
TIMER
CODES 0-1-2-3
SENSOR COOKING
BEVERAGE
REHEAT
BEVERAGE
POPCORN
POTATO
CHICKEN
FISH
TIME
COOK
AUTO
DEFROST
TIME
DEFROST
1
EXPRESS
COOK
4
EXPRESS
COOK
7
POWER
LEVEL
2
EXPRESS
COOK
5
EXPRESS
COOK
8
0
3
EXPRESS
COOK
6
EXPRESS
COOK
9
SENSOR COOKING
ADD
30 SEC
POPCORN
DISPLAY ON/OFF
START
PAUSE
CLEAR
OFF
HELP
BEEPER
VOLUME
DELAY
START
AM/PM
REMINDER
BEVERAGE
REHEAT
POTATO
VEGETABLE
CHICKEN
FISH
GUIDE BEHIND DOOR
DEFROST
AUTO/TIME
TIME COOK
CLOCK
SCROLL SPEED
1
EXPRESS
COOK
TIMER
ON/OFF
4
EXPRESS
COOK
7
POWER
LEVEL
2
EXPRESS
COOK
5
EXPRESS
COOK
3
EXPRESS
COOK
START
PAUSE
6
EXPRESS
COOK
8
HELP
9
ADD
30 SEC
0
CLEAR
OFF
DISPLAY ON/OFF
TIMER
REMINDER
DELAY
START
CLOCK
AM/PM
TURNTABLE
ON/OFF
Sensor Microwave Oven
ZMC1095SF
Microwave/
convection oven
ZE216OSF(trim)
Countertop
microwave oven
CompactZEM20OSF
microwave oven
ZMC1095SF, ZMC1095WF
and ZMC1095BF
ZE2160SF
ZEM200SF, ZEM200WF
and ZEM200BF
Oven Cavity (cu. ft.)
1.0
Power rating
800W
Overall dimensions*
(WxHxD in inches):
26-3/4 x 18-5/8 x 16-3/8
Amps @120VAC
13.0
Approx. shipping wt. (lbs.)
84
Oven Cavity (cu. ft.)
2.1
Power rating
1200W
Overall dimensions
(WxHxD in inches):
24 x 14 x 19-1/2
Amps @120VAC
13.9
Approx. shipping wt. (lbs.)
51
Oven Cavity (cu. ft.)
1.0
Power rating
800W
Overall dimensions*
(WxHxD in inches):
23-25/32 x 11-11/64 x 12-55/64
Amps @120VAC
11.5
Approx. shipping wt. (lbs.)
43
• Can be installed In a 30"
or 27" wall oven cabinet,
no kit required
• Can be installed over a 30"
or 27" wall oven
• Built-in kit available for
30" or 27" installation
• Built-in kit available for
27" installation
*Height includes feet
*Depth excludes handle
Built-in microwave/convection oven
general features
Countertop and compact
microwave oven general features
Sophisticated styling. Built-in design offers stylish,
integrated appearance.
Sophisticated styling. Electronic touch controls and a large
viewing window make a sleek, modern statement.
Three modes. The microwave/convection oven offers
three ways to cook: microwave, convection, or a
combination of both.
Sensor cooking. An electronic sensor monitors the level of steam
released by food and automatically adjusts cooking time to
deliver optimal results.
Microwave/Convection cooking. The convection mode
uses a separate heating element and fan built into the
rear wall to circulate air. This process allows gorgeous
browning and roasting. You can also convection-cook with
the microwave function for faster results, or use the oven
for microwaving only.
Flexible installation. Optional built-in kit allows cabinet or wall
installation, and an optional hanging kit allows you to mount unit
under a cabinet.
Sensor cooking. An electronic sensor monitors the level
of steam released by food and automatically adjusts
cooking time to deliver optimal results.
96
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
monogram.com
Built-in microwave/convection ovens
Compact microwave oven
The Monogram built-in microwave/convection oven is sized
to fit a 27"-wide cabinet. Side trim pieces are supplied for
installation in a 30" cabinet.
This microwave oven can be used on a countertop or hung
from kitchen wall cabinets. The hanging kit is packed with the
microwave oven.
• This microwave oven must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded branch
circuit and protected by a 15- or 20-amp circuit breaker
or time-delay fuse.
• This microwave oven can also be built into 27"-wide cabinetry.
Order JX827SMSS for stainless steel, JX827DMBB for black and
JX827DMWW for white models.
6"
Locate electrical outlet on
back wall 17" min. outside
and 19" min. inside cutout.
18"
16-3/8"
Excluding
Handle
25-1/4"
8"
Locate Outlet Box in
the Shaded Area
17-1/2"
696Dia1436" Min.
18-5/8"
27" or 30"
Cabinet
26-3/4"
• This microwave oven must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded branch
circuit and protected by a 15- or 20-amp circuit breaker
or time-delay fuse.
microwave ove n s
®
advantium ® Speedcook
wa ll oven
Advance planning for microwave ovens
18"
Locate Electrical
Outlet on Back
Wall 16" Min.
Outside
and 18" Min.
Inside Cutout
24-7/8"±1/16"
12-1/2"
16-1/4"
15"±1/16"
18-5/8"
26-1/8"
ZMC1095SF Stainless steel
ZMC1095BF Black
ZMC1095WF White
warming drawer s
29-3/4"
with side trim
27"
696Dia13
Countertop microwave oven
This large microwave oven is encased in stainless steel. It can
be used on the countertop or built in using optional kits. Order
JX2127SH for installation into a 27"-wide cabinet. Order JX2130SH
for installation into a 30" cabinet. Kits must be ordered separately
from your Monogram dealer.
ZEM200SF Stainless steel
ZEM200BF Black
ZEM200WF White
605Dia101
Locate Electrical
Outlet on Back
Wall 19-1/2" Min.
Outside and 22" Min.
Inside Cutout
3 6" out doo r
c ook ing cent e r s
• This microwave oven must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded branch
circuit and protected by a 15- or 20-amp circuit breaker
or time-delay fuse.
25-1/2"
19"
19"
16-3/4"
B
A
B
A
Dual -burn er
out d oor c ookt op
ZE2160SF
JX2127SH JX2130SH
27"
30"
26-5/8"
29-3/4"
605Dia100
Note: The trim frame protrudes forward of cabinetry to allow
air flow from the top, bottom and sides of the frame. Allow
1" clearance beyond the edge of the trim frame to provide
proper air flow.
97
Warming drawers
ZTD910BB
ZTD910BB
General features
Sophisticated styling. Built-in design with hidden controls offers
a look of understated elegance. For a personal statement,
customize the drawer with a cabinet-compatible wood panel
and your choice of handles.
Temperature settings. Monogram® warming drawers offer a
range of temperature options, from a proof setting (approximately
75°F) to a high setting (approximately 230°F).
Humidity control. By opening or closing the warming drawer vent,
you can keep foods crisp or maintain moisture.
Practical details. The design of the half rack not only
distributes heat evenly, but it also provides fifty percent
more surface area for stacking plates and food.
Installation versatility. All 30" and 27" warming drawers are
UL listed for use with Monogram wall ovens and cooktops.
Three-pan set. A set of three covered pans allows a choice of
sizes for any dish: one 6-quart pan and two 3-quart pans.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
30" warming drawer
27" warming drawer
ZTD910SFSS, ZTD910WFWW and
ZTD910BFBB
ZKD910SFS and ZKD910BFBB
Overall dimensions
(WxHxD in inches):
30 x 10-1/2 x 23-1/4
Amps @120VAC
Approx. shipping wt. (lbs.)
Overall exterior dimensions
(WxHxD in inches):
26-3/4 x 10-1/2 x 23-1/4
Amps @120VAC
Approx. shipping wt. (lbs.)
• Optional custom wood
panel kit
• Side-by-side installation
• Undercounter installation
• Under wall oven installation
• Under cooktop installation
15
65
• Optional custom wood
panel kit
• Side-by-side installation
• Undercounter installation
• Under wall oven installation
• Under cooktop installation
Advance planning for warming drawers
Electrical requirements
Custom panels and handles
Product rating is 120V, 60Hz, and connected to an
individual, properly grounded branch circuit and protected
by a 15- or 20-amp circuit breaker or time-delay fuse.
Two warming drawers installed side by side can operate
from the same duplex outlet.
The drawer fronts can be removed and replaced with a
custom panel to match surrounding cabinetry.
• Order ZXD30B for 30"-wide models and ZXD27B for 27"
models. These kits must be ordered separately from your
Monogram supplier.
• The tubular handle may be reinstalled onto the custom panel
(longer screws will be required) or replaced with a custom
handle of your choice.
26-3/4" for 27" Models
30" for 30" Models
Drill 5/16" Dia.
10-1/2" Through Custom
Panel For Lamp Jewel
1-3/4"
605Dia102
98
1-13/16"
15
59
monogram.com
Installation below a single or double oven
The warming drawer may be installed below a single or double
oven. Observe the 1" minimum clearance above the toekick, or
5" above the floor.
Installation below a countertop
The warming drawer may be installed beneath a countertop.
Install the drawer 5" minimum above the floor or 1" above
the toekick. The recommended distance from the floor to the
bottom of the cutout is 23-1/4" for undercounter installation.
Installation below a cooktop
The warming drawer is approved for installation below
specified cooktop models. A solid barrier and an air gap
between the cooktop and the warming drawer are required.
See note below.
2" Min.
9"
Allow 5/8"
Overlap on
All Sides
9-1/4"
23-1/4"
A
1" Min. Above Toekick or Adjust
to Oven Installation Height
Dim. A
28-1/2"
25-1/2"
B
Dim. B
30"
26-3/4"
605Dia110
Note: Additional clearance between cutouts may be required.
Check to be sure that oven supports, above the warming
drawer location, do not obstruct the required interior 23-1/2"
depth and 9-1/4" height.
23-1/2" Min.
Inside
Double
oven
Electrical Outlet
42" Max. From
Right Side. 1-1/2"
Cabinet
Top
25"
Solid Barrier
See Note
Electrical Outlet
Flush With
Side of Cabinet
7" Max.
7"
1" Min.*
9-1/4"
A
Solid Barrier
Allow 5/8"
Overlap on
All Sides
23-1/2" Min.
2" Min.
9"
9-1/4"
10-1/2"
1" Min. Above Toekick
Dim. A
28-1/2"
25-1/2"
B
Dim. B
30"
26-3/4"
605Dia111
1/4"
Air Gap
36"
Countertop
Height
w
elo
nB
tiower
a
l
tal ra
Ins a D
Install a Solid Barrier
and a 1/4" Air Gap
Above Warming Drawer
23-1/4"
A
ZTD910
ZKD910
Electrical
Outlet 16" Max.
From Left Side.
Install
2x4 or 2x2
Anti-Tip Block
Against Rear
Cabinet Wall
9" From Floor
to Bottom
of Block
9"
Oven
Cutout
2x2 or 2x4
Anti-Tip Block
Against Rear
Wall, 9" From
Floor to
Bottom of
Block
Installation below a cabinet drawer
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4"-thick plywood. Allow at least 1/4" air
gap between the barrier and the top of the warming drawer.
warming drawer s
Oven
Cutout
microwave ove n s
605Dia107
10-1/2"
ZTD910
ZKD910
Side-by-Side Installation
3 6" out doo r
c ook ing cent e r s
2x2 or 2x4
Anti-Tip Block
Against Rear
Wall, 9" From
Floor to
Bottom of
Block
2"
Min.
27" warming drawers
ZKD910SFSS Stainless steel
ZKD910BFBB Black
23-1/2" Min.
Inside
Single
oven
Side-by-side installation
Install two warming drawers in separate cutouts. Allow 2"
minimum between cutouts.
ZTD910
ZKD910
Dim. A
28-1/2"
25-1/2"
Dim. B
30"
26-3/4"
Dual -burn er
out d oor c ookt op
30" warming drawers
ZTD910SFSS Stainless steel
ZTD910BFBB Black
ZTD910WFWW White
advantium ® Speedcook
wa ll oven
Advance planning for warming drawers
605Dia109
*Note: When installing the warming drawer below a cooktop,
a solid barrier must be installed at least 1" from the lowest
point of the bottom of the cooktop burner box to the top of
the cutout. Use any solid material such as 1/4"-thick
plywood. Allow at least 1/4" air gap between the barrier
and the top of the warming drawer.
99
36" outdoor cooking centers
General features
Gourmet Radiant™ trays. Beneath the grill racks, these uniquely
designed trays ensure even heat distribution. They also reduce
grease flare-ups, eliminate the need for lava rocks or briquettes
and remove easily for cleanup.
Porcelain-coated, cast-iron grill burners. Two 20,000-BTU “H”
burners provide the power necessary to evenly heat the entire
grilling area.
Heavy-duty grill racks. The heavy, heat-retaining grill racks
are porcelain-enameled for easy cleaning and long life.
ROTISSERIE
GRILL
IGNITOR
GRILL
ROTESSERIE
IGNITOR
SMOKER
GRILL
IGNITOR
GRILL
SMOKER
IGNITOR
GRILL
IGNITOR
36" outdoor cooking
center
605Dia187
ZGG36N31CSS (natural gas)
Brass valves. Burner controls are mounted on durable brass
valves, ensuring long life in an outdoor environment.
ZGG36L31CSS (liquid propane)
Infrared rotisserie system. A ceramic infrared burner,
mounted behind the motorized rotisserie, reaches cooking
temperature in just 30 seconds.
Overall dimensions
(WxHxD in inches):
35-7/8 x 22 x 25-3/8
Approx. shipping wt. (lbs.)
Built-in smoker system. Includes an independent
5000-BTU burner with variable temperature control
and a full-extension, slide-out drawer for wood chips.
Slide-out drip tray. The stainless steel drip tray below
the grill and cooktop burners collects grease and spills
and slides out for easy cleaning.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
100
HOLD 10 SEC. WHILE LIGHTING
GRILL
250
• Built-in or portable
• Natural or LP gas must be
specified by model number
• Stainless steel cart available
• Insulated jacket required for
combustible enclosure
• Conversion kit available
monogram.com
36" product dimensions
Additional clearances
ZGG36N31CSS
3 grill burners,
1 rotisserie burner
(Order ZGG36L31CSS
for LP gas)
Observe all clearances shown.
• Allow at least 12" clearance on each side to combustible
vertical surfaces and at the rear when exhaust is directed
to a window or a surface that is difficult to clean.
advantium ® Speedcook
wa ll oven
Advance planning for 36" outdoor cooking centers
• Allow at least 6" clearance on each side to any
non-combustible material located above the cooking
surface. Rotisserie models also require 6" clearance for placing
and handling the motor and skewer.
Installation in a non-combustible (masonry) enclosure
The grill drops into the opening and hangs from its side flanges.
A deck is not required for support.
Install Electrical
Outlet for Rotisserie
On Right side
(6.5 AMP Min.)
12" Min. to Combustibles
3" Clearance for Lid
34-1/2"
22-3/4"
ZXADYSS stainless steel double access doors
Optional accessory to cover the access opening under
the grill in a built-in installation.
ZX36CV3Y vinyl cover fits built-in 36" models with 3 grill burners.
ZX36CTACSS 36" grill cart
This cart has a fold-down shelf on each side. Inside is a shelf for
utensils and condiment bins on the door. Behind the other door
is a slide-out tray for easy access to the LP tank.
warming drawer s
Cutouts for built-in installations
microwave ove n s
Built-in accessories
35-1/2"
Max.
18-1/2"
HOLD 10 SEC. WHILE LIGHTING
FRONT
REAR
IGNITOR
4x4 Opening
for Gas Supply
Line
9-1/8"
Opening for
Access Doors
ROTISSERIE
GRILL
ROTESSERIE
IGNITOR
Slide-Out
Tank Tray
Accessory doors ZXADYSS cutout:
24-1/8"W x 18-1/4"H
SMOKER
GRILL
IGNITOR
SMOKER
IGNITOR
GRILL
GRILL
IGNITOR
Grill cart dimensions:
36"W x 35-5/8"H x 25-1/4"D
Shelf dimensions:
21"D x 16"W
23-3/4"
35-1/2"
Max.
18-1/2"
10-1/8"
3-1/8"
Opening for
Access Doors
Cart accessories
ZX36CVCC vinyl cover fits all 36" models installed on a cart.
Type of gas
Monogram® outdoor cooking centers are factory set for either
natural or liquid propane gas. The correct model must be
ordered for the installation situation.
Conversion kits (WB49X10084, natural to LP and WB49X10083,
LP to natural) are available if the wrong gas type was ordered.
The kits must be installed by a qualified service technician at
additional cost.
Dual -burn er
out d oor c ookt op
12" Min. to Combustibles
3" Clearance for Lid
40-1/2"
Install Electrical
Outlet for Rotisserie
On Right side
(6.5 AMP Min.)
3 6" out doo r
c ook ing cent e r s
605Dia191
Installation in a combustible enclosure
ZX36JYSS insulated jacket is required
The insulated jacket must be supported from the bottom by a
solid deck or ledge on each side beneath the jacket. Construct
the enclosure as shown and place the insulated jacket into the
enclosure. Place the cooking center into the jacket.
The serial plate is located in the back of the burner box, below
the burner grates.
4x4 Opening
for Gas Supply
Line
Accessory doors ZXADYSS cutout:
24-1/8"W x 18-1/4"H
605Dia192
101
Dual-burner outdoor cooktop
General features
Porcelain-coated cast-iron burners. The spark-ignition burners
are 15,000-BTU-rated and come with a removable stainless steel
cover that doubles as a work surface. Burners are baffled to reflect
heat into the cooking area.
REAR
FRONT
IGNITOR
Precision brass valves. Controls are mounted on durable brass
valves that resist rust and corrosion, ensuring long life in an
outdoor environment.
Dual-burner
outdoor
cooktop
ZX2NYSS
Drip pan. The full-width stainless steel pan slides out easily for
removal and cleaning.
ZX2LYSS (liquid propane)
Versatile installation. The dual-burner cooktops are designed to
be built in. The cooktop provides additional outdoor cooking area
and complements the built-in 36” outdoor cooking center.
For additional details on product installation, warranty coverage,
care and maintenance, visit monogram.com.
ZX2NYSS (natural gas)
Overall dimensions
(WxHxD in inches):
13 x 10-1/2 x 25-3/4
Approx. shipping wt. (lbs.)
56
• For built-in installations
• Natural or LP gas must be
specified by model number
• Trim kit required for enclosure
• Insulated jacket required for
combustible enclosure
Advance planning for dual-burner outdoor cooktop
Dual-burner outdoor cooktops are factory set for natural or
liquid propane gas. The correct model should be ordered for the
installation situation.
These cooktop burners are designed for outdoor use only.
• The burner is designed to be built into an enclosure.
2x2
Opening
for Gas
Supply
Line
13-1/8"
23-5/8"
10-3/8"
Product dimensions
Installation in a combustible enclosure
ZX2JYSS insulated jacket is required
The insulated jacket must be
2x2
supported from the bottom by
Opening
a solid deck or ledge on each
for Gas
Supply
side beneath the jacket.
Line
Construct the enclosure as
1"
shown and place the insulated
jacket into the enclosure.
605Dia208
ZX2NYSS
Natural gas
ZX2LYSS
LP gas
10-1/2"
23-3/4"
25-3/4"
13"
15-3/8"
11"
24-5/8"
1-1/8"
2"
Accessories
Clearances
605Dia206
• When installed in an enclosure, allow 6" clearance at the rear
and both sides to vertical combustible materials.
• When installed into a combustible enclosure, the cooking
surface should be 1" above adjacent horizontal surfaces and
35-1/2" above the floor.
102
Installation in a non-combustible
(masonry) enclosure
The burner drops into the
opening. The burner must
be supported by a solid deck.
605Dia209
ZX2TKYSS trim kit
For combustible and non-combustible enclosures. The trim
will conceal the gap at the rear and sides of the opening. The
cooktop should be installed at least 35-1/2" above the floor.
Dual -burn er
out d oor c ookt op
3 6" out doo r
c ook ing cent e r s
warming drawer s
microwave ove n s
advantium ® Speedcook
wa ll oven
monogram.com
Notes
103
Notes
104
monogram.com
Notes
105
Notes
106
p e r s p e c t i v e s
D e s i g n G u i d e A GE M O N O GR A M PU B L IC ATI O N As an ENERGY STAR® partner, GE has determined that the appliances marked with
the ENERGY STAR logo meet the ENERGY STAR guidelines for energy efficiency.
Before purchasing an ENERGY STAR qualified appliance, read important information
about its estimated annual energy consumption or energy efficiency rating that is
available from your retailer, monogram.com or www.energystar.gov.
Product improvement is a continuing endeavor at GE. Therefore, materials,
appearance and specifications are subject to change without notice.
2007
© 2007 GE Company Publication Number 24-M577 PC49881
perspectives
monogram 2007 design guide