Download Monogram ZV54I Specifications
Transcript
p e r s p e c t i v e s D e s i g n G u i d e A GE M O N O GR A M PU B L IC ATI O N As an ENERGY STAR® partner, GE has determined that the appliances marked with the ENERGY STAR logo meet the ENERGY STAR guidelines for energy efficiency. Before purchasing an ENERGY STAR qualified appliance, read important information about its estimated annual energy consumption or energy efficiency rating that is available from your retailer, monogram.com or www.energystar.gov. Product improvement is a continuing endeavor at GE. Therefore, materials, appearance and specifications are subject to change without notice. 2007 © 2007 GE Company Publication Number 24-M577 PC49881 perspectives monogram 2007 design guide Exceptional service is a Monogram standard. Monogram® offers a feature no other brand can match: customized services that begin before you’ve selected your appliances and continue until well after your Monogram home has become a reality. The Monogram Collection™, a superb line of kitchen appliances with a package of services to match. Visit monogram.com. Find Monogram product information, specifications, installation instructions and owner’s manuals. Also, schedule services and order parts online, anytime. GE QuickSpecs, 800.432.3729. Request dimensions and specifications on any Monogram appliance and have the data transmitted, within minutes, to the fax number you provide. Monogram Preferred Service, 800.444.1845. If your Monogram appliance should ever require service, you can depend on Monogram Preferred Service. Simply call the above number 7 a.m. - 10 p.m. EST, Monday through Friday, 8 a.m. - 6 p.m. EST, Saturday and Sunday, to schedule your service appointment. GE Answer Center®, 800.626.2000. For product assistance and answers to your questions about Monogram appliances, 6:00 a.m. – 12:00 a.m. Monday through Saturday. monogram.com GE Monogram Design Guide Monogram appliance planning: ® from inspiration to installation. Table of content s 3 Introduction 4 Refrigeration Built-in side-by-side refrigerators Built-in bottom-freezer refrigerators Now more than ever, the kitchen is the heart of the home. It’s the place where we relax and gather in the company of family and friends. That’s why, when you build a new home or 4–11 12–19 Built-in all-refrigerators and all-freezers20–23 Stainless steel-wrapped free-standing refrigerators24–25 Customization options26 27 Refrigeration modules Double-drawer refrigerator27–28 Fresh-food and bar refrigerator29–30 remodel, the kitchen becomes the center of your plans. It serves as your canvas for artistic expression. The Monogram Design Guide makes Outdoor/indoor refrigerator31–32 Wine reserve and beverage center33–35 36 Icemakers and compactors 40 Dishwashers 43 Professional ranges 48" dual-fuel professional ranges 43–44 36" dual-fuel professional ranges 45–46 the kitchen—and throughout the home. With 30" dual-fuel professional ranges 47–48 detailed information on product specifications, it easy to express your creative vision in dimensions and installation, the Monogram Design Guide helps bring your home design plans to life. Whether you’re a designer, builder, architect or do-it-yourselfer, you’ll find everything you need to select and install Monogram appliances, including many exciting options for customization. Should you require additional planning guidelines 49 Gas cooktops 48" gas cooktops 49–50 36" gas cooktops 51–52 53–55 Stainless steel and gas-on-glass gas cooktops 56 Induction and electric cooktops Induction cooktops 56–57 Digital electronic and electric cooktops 58–59 60 Ventilation systems Chimney hoods 61–71 Professional hoods 72–78 Custom hood inserts 79–80 Telescopic downdraft vents 81–86 87 Wall ovens Electronic wall oven with Trivection® technology 87 Integrated and professional convection wall ovens 88–89 and resources, simply visit us online at Electronic convection wall oven 90–91 monogram.com. 93 Companion cooking products Wall oven with Advantium® Speedcook technology 93–95 Microwave ovens 96–97 Warming drawers 98–99 36" outdoor cooking centers Dual-burner cooktop 100–101 102 Built-in side-by-side refrigerators DOOR ALARM CONTROL LOCK DOOR ALARM CONTROL LOCK 48" built-in refrigerator with dispenser 48" built-in professional refrigerator with dispenser 48" built-in refrigerator ZISW480DR, ZISB480DR, ZISB480DM.EPS ZISS480DRSS* ZISP480DTSS* ZIS480NR, ZISS480NRSS* ZISB420DM.EPS ZISW420DR, ZISB420DR, ZISS420DRSS* Overall dimensions (WxHxD in inches): 48 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 775 Overall dimensions (WxHxD in inches): 48 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 775 Overall dimensions (WxHxD in inches): 48 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 775 Overall dimensions (WxHxD in inches): 42 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 725 • 30.7 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged unified grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door panels required on custom models • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels • 30.7 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged unified grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Professional handles • 30.6 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged unified grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door panels required on custom models • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels • 26.1 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door panels required on custom models • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels ZISW480DM.EPS ZISP480_A10911.EPS *Stainless steel-wrapped doors ZIS480NM.EPS 42" built-in refrigerator with dispenser ZISW420DM.EPS *Stainless steel-wrapped doors *Stainless steel-wrapped doors *Stainless steel-wrapped doors For kosher kitchens, an optional kit allows Monogram side-by-side refrigerators and bottom-freezer refrigerators to run in Sabbath mode. monogram.com B u i l t- i n s i d e - b y - s i d e refrigerators Built-in side-by-side refrigerators DOOR ALARM CONTROL 42" built-in professional refrigerator with dispenser ZIS420_A10913.EPS ZISP420DTSS* 42" built-in refrigerator ZISS420NM.EPS ZIS420NR, ZISS420NRSS* 36" built-in refrigerator with dispenser ZISW360DM.EPS ZISB360DM.EPS ZISW360DR, ZISB360DR, B u i l t- i n b o t t o m - f r e e z e r refrigerators LOCK 36" built-in refrigerator ZIS360NM.EPS ZIS360NR, ZISS360NRSS* Overall dimensions (WxHxD in inches): 42 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 725 Overall dimensions (WxHxD in inches): 36 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 675 Overall dimensions (WxHxD in inches): 36 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 675 • 26.1 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Professional handles • 26.0 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door panels required on custom models • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels • 21.7 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door panels required on custom models • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels • 21.6 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinges • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door panels required on custom models • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels *Stainless steel-wrapped doors *Stainless steel-wrapped doors *Stainless steel-wrapped doors *Stainless steel-wrapped doors Free -standing side - by-side refrigerators Overall dimensions (WxHxD in inches): 42 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 725 B u i l t- i n a l l - r e f r i g e r a t o r s all-freezers ZISS360DRSS* General features Customization. Monogram® built-in custom refrigerators require door and grille panels available from your Monogram dealer. They also accept custom overlay panels and handles. ENERGY STAR® qualified. As an ENERGY STAR partner, GE has determined that all Monogram side-by-side refrigerators meet the ENERGY STAR guidelines for energy efficiency. Direct airflow. Cool air is delivered straight from the overhead evaporator to freezer and fresh food compartments, allowing independent airflow for each food zone without any direct air exchange. Dispenser with proximity sensor. Tall design accommodates glassware of all sizes, from pitchers to tumblers. Control graphics light up as you approach and automatically switch off when you walk away. Spacious interior. The overhead location of the evaporator makes Monogram side-by-side refrigerators among the largest-capacity built-in refrigerators available. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. Advance planning for built-in side-by-side refrigerators Side-by-side refrigerators are available in 36", 42" and 48" widths. Design and installation considerations are the same for all model widths. Product dimensions The installation space 36" Models 12" 42" Models 18" 48" Models 20" Case Depth: 25-3/8" Framed Models 25-3/4" Stainless Steel Models 35", 41", or 47" Case Width *Finished Width 84-1/2" max 83-1/2" min Finished Opening 6" Electrical Area 5" 75" From Floor to Bottom of Electrical Area 24" 5" Water Supply 5" 3-1/2" 36", 42", or 48" Frame to Frame Depth Including Handles: 26-7/8" Framed Models 27-3/4" Stainless Steel Models 28-11/16" Professional Models 3-1/2" Space is the first consideration when planning the installation. * The finished cutout width must be: 35-1/2" min. for 36" wide models 41-1/2" min. for 42" wide models 47-1/2" min. for 48" wide models 696Dia15 The cutout depth must be 24" The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation. The cutout depth beneath a soffit When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit. Electrical A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown. *84" From Floor to Top Frame *83-1/2" at Rear *Shipping height. The refrigerator can be adjusted to fit into a cutout that is 83-1/2" min. to 84-1/2" max. height. The top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1" height adjustment. 429Dia8 Door swing clearances The installation must allow for clearances to adjacent walls or cabinets. These refrigerators are equipped with a 2-position door stop. The factory-set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90° and 130°. A B 130° Door Swing 90° Door Swing The serial plate is located above the freezer compartment and behind the grille panel. C Note: GFI (ground fault interrupter) is not recommended. Water line All models are equipped with an automatic icemaker. The water line can enter the opening through the floor or back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location. The tubing should be long enough to extend to the front of the refrigerator. The installation of an easily accessible shut-off valve in the water line is required. 23-7/8" Behind Frame 4" Min. to Wall 5" Min. for Professional Models Models 36" 42" 48" A B C 15"20-5/8" 13" 19"26-5/8" 15"20"28-5/8" 605Dia413" 605Dia5 Observe all minimum clearances shown above for a 130° or 90° door swing. A 90° door swing allows pan access, but removal is restricted. • See door swing illustrations to determine interaction with adjacent cabinets or countertops. monogram.com B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in side-by-side refrigerators Customization basics: Framed or overlay panels, custom handles and accessor y kits ZISP480DTSS, ZISP420DTSS Stainless steel wrapped refrigerators with professional handles and chamfered door edges. These models are shipped ready for installation. Overlay panels You may also choose to install custom overlay panels from your cabinet manufacturer. This design provides a seamless appearance which integrates smoothly with surrounding cabinetry. B u i l t- i n b o t t o m - f r e e z e r refrigerators Built-in stainless steel side-by-side refrigerators with professional styling Built-in stainless steel side-by-side refrigerators with integrated styling ZISS360NRSS, ZISS360DRSS ZISS420NRSS, ZISS420DRSS ZISS480NRSS, ZISS480DRSS ZIS360NR, ZISW360DR, ZISB360DR ZIS420NR, ZISW420DR, ZISB420DR ZIS480NR, ZISW480DR, ZISB480DR Custom panel refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required. Framed panels You may install 1/4"-thick custom panels from your cabinet manufacturer. The decorative panels slide into the factoryinstalled trim. Or, order black or stainless steel accessory panels from your Monogram dealer. 1/4" Thick Backer Panel Standard supplied handles shown in 3/4" overlay panel position. B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers Custom panel refrigerators 3/4" Overlay Panel .10" Thick Spacer Panel Door handles The supplied handles can be adjusted to accommodate both framed or overlay panels. Custom handles of your choice, supplied by your cabinetmaker, can also be installed. If desired, you may order ZKHSS2 Monogram stainless steel tubular handle kit for overlay panels. 696Dia2 Side panels Side panels must be used whenever the sides of the refrigerator will be exposed. Optional accessory kit ZKHSS2: Tubular stainless steel handles designed to fit 3/4" overlay panels. Free -standing side - by-side refrigerators Integrated stainless steel refrigerators have wrapped doors and grille panel, beveled edges and tubular stainless steel handles that coordinate with other Monogram® appliances. These models are shipped ready for installation. Accessory panels Black acrylic and stainless steel accessory panels are available from your Monogram supplier. Panels are cut to size and ready to install. These panel kits must be ordered separately. Framed Panel Standard supplied handles shown in 1/4" panel position. 605Dia6 Black Stainless Models acrylic steel ZISW480DZPS480D ZISB480DZPB480DZPS480D ZIS480NZPB480NZPS480N ZISW420DZPS420D ZISB420DZPB420DZPS420D ZIS420NZPB420NZPS420N ZISW360DZPS360D ZISB360DZPB360DZPS360D ZIS360NZPB360NZPS360N Advance planning for built-in custom side-by-side refrigerators 3/4" overlay panel dimensions For a more custom appearance, overlay panels may be installed on trimmed models. The overlay panel must be secured to a 1/4"-thick backer panel which slides into the trim. A spacer panel 0.10" thick must be placed between the overlay and backer panels. Raised overlay panel design on dispenser models Door Center each panel over the other. Assemble the panels with glue and screws. Screws must be countersunk into the backer panel. 3/4" Overlay Panel • The middle rail must be wide enough to allow for the dispenser trim to overlap the opening. • The middle rail must be 1.100" total thickness to accept the dispenser trim. 1/4" Backer Panel .10" Spacer 3/4" Overlay Panel 1/4" Backer Panel .250" + .10" + .750" = 1.100" Total panel thickness When a raised panel design is to be used, a custom wide middle rail is required to accept the dispenser trim. .10" Spacer Overlay Panel 194Dia58 Spacer Panel Dispenser Trim Wide Middle Rail is Required 16-3/4" Backer Panel Note: Left-to-right offset is not always equal to top-to-bottom offset. 10-5/8" Side view 194Dia65 A Grille Panel Dispenser Cutout 36" side-by-side (in inches) A 1/4" backer panel33-7/8 .10" spacer panel33 3/4" spacer panel34-1/8 B F C G Freezer Panel Fresh Food Panel D E Dispenser Cutout 15-3/8" 9-5/8" *Cut the dispenser opening after the backer, spacer and overlay panels have been assembled. 194Dia64 B C 8-3/8 9-1/4 D 14-9/16 67 13-1/4 68-5/8 14-13/16 42" side-by-side (in inches) A 1/4" backer panel39-7/8 .10" spacer panel39 3/4" spacer panel 40-1/8 B 9-1/2 8-5/8 9-3/4 C 68-3/8 67 68-5/8 D E 14-9/1624-9/16 13-1/423-1/4 14-13/1624-13/16 48" side-by-side (in inches) A 1/4" backer panel 45-7/8 .10" spacer panel 45 3/4" spacer panel 46-1/8 B 9-1/2 8-5/8 9-3/4 C 68-3/8 67 68-5/8 D E 18-9/1626-9/16 17-1/425-1/4 18-13/1626-13/16 194Dia82 9 68-3/8 194Dia63 Important note: Maximum weight for fresh food panel is 75 pounds, 53 pounds for freezer panel and 18 pounds for the grille panel. *Dispenser cutout position (in inches) F G 36" models 17-15/163-1/4 42" models 17-15/163-1/4 48" models 17-15/16 5-1/4 E 18-9/16 17-1/4 18-13/16 monogram.com If you choose to install framed panels, they must be cut to the dimensions shown. The panels will slide into the frame on the door and grille. Dispenser models 5/16" Trim Reveal Door 1/4" Panel If the custom panel is less than 1/4" thick, and it fits loosely in the door frame, it can be backed up with a piece of filler material or foam tape to improve the fit. 1/4" framed panel The framed panel must be 1/4" nominal thickness to fit the dispenser trim. • The dispenser trim fits over the custom panel and snaps into the freezer door. • If the panel is less than 0.250" thick, a noticeable gap may be created around the dispenser trim. Foam tape may be applied on the door to improve the fit. Important note: Maximum weight for fresh food panel is 75 pounds, 53 pounds for freezer panel and 18 pounds for the grille panel. • If the panel is more than 0.250" thick, the dispenser trim cannot be secured to the door. 194Dia59 A 1/4" Framed Panel B FREEZER DOOR 0.250" Thick Ice / Water Dispenser B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers Grille Panel These refrigerators are supplied with two dispenser trims, one for framed panels and one for overlay panels. B u i l t- i n b o t t o m - f r e e z e r refrigerators 1/4" framed panel dimensions B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in custom side-by-side refrigerators 1/4" Dispenser Trim F 3/4" overlay panels Freezer Panel D • If the panel is less than 1.100" thick, a noticeable gap may be created around the dispenser trim. 15-3/8" Fresh Food Panel 9-5/8" E Side-by-side (in inches) A 36" models33-7/8 42" models39-7/8 48" models 45-7/8 194Dia64 696Dia3 Dispenser Cutout C G The overlay dispenser trim is designed to fit a total panel thickness of 1.100". B 9 9-1/2 9-1/2 C 68-3/8 68-3/8 68-3/8 Dispenser cutout position (in inches) F G 36" models 17-13/163-1/8 42" models 17-13/163-1/8 48" models 17-13/16 5-1/8 D E 14-9/16 18-9/16 14-9/1624-9/16 18-9/1626-9/16 194Dia63 • If the panel is more than 1.100" thick, the dispenser trim cannot be secured to the door. • The overlay panel must be constructed according to the specifications shown to achieve the correct total thickness. Free -standing side - by-side refrigerators Dispenser Cutout • Alternative panel construction methods such as securing a 3/4" panel to a 1/4" backer panel cannot be used. Another method, routing a 3/4"-thick panel on all sides, cannot be used. These methods will not result in the required 1.100" panel thickness. • When a raised panel design is to be used, a custom middle rail is required. See page 8 for details. 1/4" Backer Panel FREEZER DOOR .10" Spacer Panel 1.100" Total Thickness Ice / Water Dispenser 3/4" Overlay Panel 3/4" Overlay Dispenser Trim 696Dia4 Advance planning for built-in custom side-by-side refrigerators Frameless cabinets: The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips. Use this page to determine door swing interaction with adjacent cabinets or countertops. Refrigerator 23-7/8" From Rear of Refrigerator Case Trim 3/4" 1/2" 1/4" 1" 1-3/4" 2" 1-1/2" 2-3/4" 3" 2-1/2" 1-1/4" 2-1/4" 1/4" 1/2" 3/4" 1" l tee sS les ain St 3/4" Overlay Panel (Nominal Size) Door Top view 130° door swing (Factory setting) Scale 1:1 IMPORTANT NOTE – FOR DISPENSER MODELS 10 Dispenser models are supplied with two dispenser trims, one to fit framed panels and one for overlay panels. Dispenser trim fit to the custom panel depends on correct panel thickness. Framed panels must be 1/4" nominal. Overlay panels should be constructed as shown to accomplish a total 1.100" thickness. 1/4" 1/2" 3/4" 1" 1-1/4" monogram.com Use this page to determine door swing interaction with adjacent cabinets or countertops. B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in custom side-by-side refrigerators Refrigerator Case Trim B u i l t- i n b o t t o m - f r e e z e r refrigerators 23-7/8" From Rear of Refrigerator Frameless Cabinets: The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips. B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers 1/4" 1/2" 3/4" 1" 1-1/4" IMPORTANT NOTE – FOR DISPENSER MODELS Dispenser models are supplied with two dispenser trims, one to fit framed panels and one for overlay panels. Dispenser trim fit to the custom panel depends on correct panel thickness. Framed panels must be 1/4" nominal. Overlay panels should be constructed as shown to accomplish a total 1.100" thickness. Stainless Steel Top view 90° door swing (Optional setting) Scale 1:1 Free -standing side - by-side refrigerators 1-1/2" Door 3/4" Overlay Panel (Nominal Size) 1/4" 1/2" 3/4" 1" 1-1/4" 11 Built-in bottom-freezer refrigerators General features Customization. Monogram® built-in custom refrigerators require door and grille panels. These models also accept framed or overlay custom panels from your cabinetmaker. Stainless steel–wrapped models are shipped ready for installation. Temperature management system. The temperature management system with upfront electronic controls delivers cool, fresh air to every shelf. Flexible storage. In the freshfood compartment, four split shelves and six adjustable door bins offer convenient access to contents. The large fullextension freezer drawer has an automatic icemaker and storage bins that slide out independently of one another for easy loading and unloading. ENERGY STAR® qualified. As an ENERGY STAR partner, GE has determined that all Monogram bottom-freezer refrigerators meet the ENERGY STAR guidelines for energy efficiency. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 12 36" built-in stainless steel refrigerators ZICS360NM.EPS 36" built-in professional refrigerators ZICP360_A10617.EPS 36" built-in refrigerators ZIC360NMRH.EPS ZICS360NRRH, ZICS360NRLH ZICP360SLSS, ZICP360SRSS ZIC360NRRH, ZIC360NRLH Overall dimensions (WxHxD in inches): 36 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 675 Overall dimensions (WxHxD in inches): 36 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 675 Overall dimensions (WxHxD in inches): 36 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 675 • 20.6 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinge • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Stainless steel-wrapped doors • Trimmed (semi-flush) installation • Door swing preference must be specified • Unified grille kit for side-by-side installation of two bottom-freezer refrigerators • 20.6 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinge • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Stainless steel-wrapped doors, professional handles and louvered grille panel • Trimmed (semi-flush) installation • Door swing preference must be specified • 20.6 cu. ft. capacity • Energy STAR qualified • Equipped to accept optional Sabbath mode kit, zsab1 • Concealed door hinge • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation • Door swing preference must be specified • Door panels required • No kits required for customization • Two-position handle adjusts to accommodate 1/4" framed or 3/4" overlay panels • Unified grille kit for side-by-side installation of two bottom-freezer refrigerators Note: These professional bottom-freezers are not designed for side-by-side or unified installations. For kosher kitchens, an optional kit allows Monogram side-by-side refrigerators and bottom-freezer refrigerators to run in Sabbath mode. monogram.com B u i l t- i n s i d e - b y - s i d e refrigerators Built-in 72" professional bottom-freezer refrigerators General features Professional appearance. Professional commercial-grade stainless steel appearance with professional handles and chamfered edges. The full-width grille panel and toekick provides a smooth and impressive statement. A "U" shaped trim strip covers the space between the middle case trims for a perfectly finished look. ZICP720_A10616.EPS ZICP720SSS* Overall dimensions (WxHxD in inches): 72 x 84 x 23-7/8 (behind frame) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 1,350 B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 72" professional bot tom-freezer refrigerators • 41.2 cu. ft. capacity • Equipped to accept optional Sabbath mode kit, zsab1 (2) • Concealed door hinge • Easy access hinged grille • Four-point leveling system • Adjustable door stop (90°/130°) • Trimmed (semi-flush) installation Free -standing side - by-side refrigerators Flexible storage. In the fresh-food compartments, four split shelves and six adjustable door bins on each side offer convenient access to contents. Large full-extension freezer drawers have automatic icemaker and storage bins that slide out independently of one another for easy loading and unloading. B u i l t- i n b o t t o m - f r e e z e r refrigerators Temperature management system. The temperature management system with upfront electronic controls delivers cool, fresh air to every shelf. *This product consists of 3 SKU's. You must order all 3 SKU's to complete this product: 1. ZICP720SSS: Unified grille, toekick and parts 2.ZICP720ASSS: refrigerator, left-side 3.ZICP720BSSS: refrigerator, right-side 13 Advance planning for built-in bottom-freezer refrigerators The installation space Door swing clearances The finished cutout width must be 35-1/2". The installation must allow for clearances to adjacent walls or cabinets. These refrigerators are equipped with a 2-position door stop. The factory-set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90° and 130°. 35-1/2" Finished Width Wall View 2-5/16" 6" 10" 84-1/2" max 83-1/2" min Finished Opening Electrical Area 75" From Floor to Bottom of Electrical Area 24" Cutout Depth 5" Water Supply 25" Min. to Wall 130° Door Swing 90° Door Swing 23-7/8" Behind Frame 5" 36-3/4" 3 1/2" 3 1/2" The cutout depth must be 24" The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation. The cutout depth beneath a soffit When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit. Electrical A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown. 696Dia7 Note: GFI (ground fault interrupter) is not recommended. Water line All models are equipped with an automatic icemaker. The water line can enter the opening through the floor or back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the front of the refrigerator. The installation of an easily accessible shut-off valve in the water line is required. Product dimensions 35" Case Width 14 36" Frame to Frame Width Depth Including Handles: 26-7/8" Framed Models 27-3/4" Stainless Steel Models 28-11/16" Professional Models 429Dia9 4" Min. to Wall 5" Min. for Professional Models 605Dia20 Observe all minimum clearances shown above for a 130° or 90° door swing. A 90° door swing allows pan access, but removal is restricted. 605Dia21 • 4" minimum clearance is required when the door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted. • See door swing illustrations to determine interaction with adjacent cabinets or countertops. ZUG2, ZUGSS2 unified grille panel kit • If you are installing two refrigerators side by side, the installation space must be 71-1/2" wide. Note: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width. • The water and electrical locations for each product must be located as shown. • A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product. Case Depth: 25-3/8" Framed Models 25-3/4" Stainless Steel Models *84" From Floor to Top Frame *83-1/2" at Rear 90° 130° *Shipping height. The refrigerator can be adjusted to fit into a cutout that is 83-1/2" min. to 84-1/2" max. height. The top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1" height adjustment. 71-1/2" Finished Width 2-5/16" 10" 10" 84-1/2" max 83-1/2" min Finished Opening Wall View 24-3/16" 6" Electrical 24" Cutout Depth 5" Water Supply 3-1/2" 26" Water Supply 5" 26" 75" From Floor to Bottom of Electrical Area 3-1/2" The serial plate is located inside the fresh food compartment, below the bottom storage drawer on the right side. 696Dia8 monogram.com The installation space Corner installation The finished cutout width must be 71-1/2". • These refrigerators are equipped with a 2-position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Electrical 6“ 10“ 10“ 24“ Cutout Depth 5“ 3-1/2“ Water Supply 26“ Water Supply 26“ 5“ 75“ From Finished Floor to Bottom of Electrical Area • Order WX14X99 door stops for precise settings between 90° and 130°. Order 2 doors stops, one for each door. 25" Min. to Wall 0" 130° Door Swing 130° Door Swing 25" Min. to Wall 3-1/2“ Note: The case trim overlaps cabinets at the top an sides. Frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening width must allow for filler strips. See installation instructions for details. The cutout depth must be 24" The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation. Electrical Separate 115V, 60Hz., 15 or 20 amp power supply with individual properly grounded branch circuits or circuit breakers are recommended. Install properly grounded 3-prong electrical receptacles recessed into the back wall. Electrical must be located on rear wall as shown. Note: GFI (ground fault interrupter) is not recommended. Water line Both refrigerators are equipped with an automatic icemaker. The water lines can enter the opening through the floor or back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the front of the refrigerator. The installation of an easily accessible shut-off valve in the water line is required. Allow 25" minimum clearance for a full 130° door swing. Allow 15" for pan removal. 695Dia3 5" minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is use, pan access is maintained, but pan removal is restricted. 90° Door Swing 23-7/8" Behind Frame B u i l t- i n a l l - r e f r i g e r a t o r s all-freezers 84-1/2“ max 83-1/2“ min Finished Opening Wall View 24-3/16“ 6“ 36-3/4" 90° 5" Min. to Wall Free -standing side - by-side refrigerators 2-5/16“ B u i l t- i n b o t t o m - f r e e z e r refrigerators 71-1/2“ Finished Width B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for 72" professional bottom-freezer refrigerators zicp_bf_ref_qs_art Product dimensions 71-1/2" Case Width 25-3/4" Case Depth 84"* 83-1/2" at Rear *Shipping height. The refrigerators can be adjusted to fit into a cutout that is 83-1/2" min. to 84-1/2" max. Note that the top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1" height adjustment. 72" Frame to Frame Width 28-11/16" Depth Including Handles 15 Advance planning for built-in bottom-freezer refrigerators Customization basics: framed or overlay panels, custom handles and accessor y kits These bottom-freezer refrigerators are factory set for a left or right door swing. The door swing is NOT reversible. Choose an RH model with hinge on the right side; the door swings left to right. Choose an LH model with hinge on the left side; the door will swing right to left. Right-hand door swing Left-hand door swing Professional refrigerators ZICP360SLSS, ZICP360SRSS Stainless steel wrapped refrigerators with professional handles, louvered grille panel and chamfered door edges. These models are shipped ready for installation. Stainless steel refrigerators ZICS360NRLH, ZICS360NRRH Stainless steel refrigerators have wrapped doors and grille panel, beveled edges and tubular stainless steel handles. These models are shipped ready for installation. Custom refrigerators ZIC360NRLH, ZIC360NRRH Custom refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required. Framed panels You may install 1/4"-thick custom panels from your cabinet manufacturer. The decorative panel or accessory panel slides into the factory-installed trim. Door handles The supplied handles can be adjusted to accommodate both framed or overlay panels. Custom handles of your choice, supplied by your cabinetmaker, can also be installed. If desired, you may order ZKHCSS2 Monogram® stainless steel tubular handle kit for overlay panels. 605Dia26 Side panels Side panels must be used whenever the sides of the refrigerator will be exposed. Optional accessory kits ZKHCSS2: Monogram stainless steel tubular handle kit and handle side trim for custom handles. For use on 3/4" custom panels. ZKHCT: Handle side trim kit for left-hand and right-hand doors. For use on 3/4" custom panel when using a custom handle. ZUG2: For side-by-side installation of two trimmed bottomfreezer refrigerators. This kit provides for the installation of a unified custom grille panel to span the width of two units using a framed or overlay panel. ZUGSS2: For side-by-side installation of two stainless steel–wrapped bottom-freezer refrigerators. This kit provides a unified stainless steel grille panel to span the width of two units. Standard Door Handle Framed Panel Standard supplied handles shown in 1/4" panel position. Overlay panels You may also choose to install custom overlay panels from your cabinet manufacturer. This design provides a seamless appearance which integrates smoothly with surrounding cabinetry. 729Dia65 Standard Door Handle 16 3/4" Overlay Panel .10" Thick Spacer Panel 1/4" Thick Backer Panel Standard supplied handles shown in 3/4" overlay panel position. Accessory panels Black acrylic and stainless steel accessory panels are available from your Monogram supplier. Panels are cut to size and ready to install. These panel kits must be ordered separately. Black Stainless steel ZPBC360ZPSC360 monogram.com 1/4" Panel If the custom panel is less than 1/4" thick, and it fits loosely in the door frame, it can be backed up with a piece of filler material or foam tape to improve the fit. Important note: Maximum weight for fresh food panel is 58 pounds, 28 pounds for freezer drawer panel and 11 pounds for the grille panel. B Fresh Food Panel C Freezer Drawer Panel Door/Drawer 1/4" Backer Panel 729Dia84 A Grille Panel For a more custom appearance, overlay panels may be installed on trimmed models. The overlay panel must be secured to a 1/4"-thick backer panel which slides into the trim. A spacer panel 0.10" thick must be placed between the overlay and backer panel. Overlay Panel B u i l t- i n b o t t o m - f r e e z e r refrigerators Door/Drawer 5/16" Trim Reveal .10 Inch Spacer .250" + .10" + .750" = 1.100" total panel thickness 729Dia42 Center each panel over the other. Assemble the panels with glue and screws. Screws must be countersunk into the backer panel. Overlay Panel Spacer Panel Backer Panel Note: Left-to-right offset is not always equal to top-to-bottom offset. D Free -standing side - by-side refrigerators If you choose to install framed panels, they must be cut to the dimensions shown. The panels will slide into the frame on the door, drawer and grille. 3/4" overlay panel dimensions B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers 1/4" framed panel dimensions B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in custom bottom-freezer refrigerators 194Dia65 ZUG2 grille panel dimensions Framed panel dimensions (in inches) A (width) B (grille ht.) 1/4" framed panel33-7/8 8-7/8 729Dia89 3/4" overlay panel dimensions (in inches) A (width) B (grille ht.) 1/4" backer panel33-7/8 8-7/8 .10" spacer panel32-1/2 7-5/8 3/4" overlay panel34-1/8 9 C (FF ht.) D (FZ ht.) 46-1/1621-7/8 The ZUG2 unified grille panel kit will accept a framed or overlay grille panel. • Assemble the overlay panel in the same manner as the door and drawer panels. A C (FF ht.) D (FZ ht.) 46-1/1621-7/8 44-11/1620-1/2 46-5/1622 B Grille Panel Important: Grille panel maximum total weight is 25 lbs. Framed panel dimensions A (width) 1/4" framed panel 69-7/8" B (height) 8-7/8" Overlay panel dimensions A (width) 1/4" backer panel 69-7/8" .10" spacer panel 68-1/2" 3/4" overlay panel 70-1/8" B (height) 8-7/8" 7-5/8" 9" 729Dia85 17 Advance planning for built-in custom bottom-freezer refrigerators Frameless cabinets: The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips. Use this page to determine door swing interaction with adjacent cabinets or countertops. Refrigerator 23-7/8" From Rear of Refrigerator Case Trim 3/4" 1/2" 1/4" 1" 1-3/4" 2" 1-1/2" 2-3/4" 3" 2-1/2" 1-1/4" 2-1/4" 1/4" 1/2" 3/4" 1" l tee sS les ain St 3/4" Overlay Panel (Nominal Size) Door 18 Top view 130° door swing (Factory setting) Scale 1:1 1/4" 1/2" 3/4" 1" 1-1/4" monogram.com Use this page to determine door swing interaction with adjacent cabinets or countertops. B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in custom bottom-freezer refrigerators Refrigerator Case Trim B u i l t- i n b o t t o m - f r e e z e r refrigerators 23-7/8" From Rear of Refrigerator Frameless cabinets: The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips. B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers 1/4" 1/2" 3/4" 1" 1-1/4" Stainless Steel Free -standing side - by-side refrigerators 1-1/2" Door 3/4" Overlay Panel (Nominal Size) 1/4" 1/2" Top view 90° door swing (Optional setting) Scale 1:1 3/4" 1" 1-1/4" 19 Built-in custom all-refrigerators and all-freezers ZIR36NDRH/ZIF36NDRH ZIR36NDLH/ZIF36NDLH All-refrigerator general features Adjustable shelves and bins. Split shelves move up and down for custom storage arrangement and raised edges help contain spills. Six adjustable door bins (two for gallon-size containers) add important storage flexibility. There are also two door dairy compartments that seal for longer freshness. Produce and snack pans. Vegetable compartments with individual humidity controls, as well as sealed snack pans, glide open smoothly. All-freezer general features Adjustable shelves and bins. Five wire shelves move up and down for custom storage arrangement. Ten adjustable door bins (two for gallon-size containers) enhance storage flexibility. Specialized storage baskets. Eight pullout wire baskets with clear-view fronts (two with lids) allow compartmentalized storage for different food types. All-refrigerator and all-freezer general features Customization. Monogram® built-in custom all-refrigerators and all-freezers require door and grille panels. Models can be equipped with 1/4" door panels available from your Monogram dealer (black Lexan® and stainless steel). Also available is a unified-grille panel kit for either 3/4"-thick custom panels or stainless steel wrap. Left- or right-hinged door swing. Door-swing preference must be specified when ordering. (Handles and hinges are not reversible.) For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 36" built-in all-refrigerator 36" built-in all-freezer ZIR36NMRH, ZIR36NMLH, ZIRS36NMRH*, ZIRS36NMLH* ZIF36NMRH, ZIF36NMLH, ZIFS36NMRH*, ZIFS36NMLH* Overall dimensions (WxHxD in inches): 36 x 84 x 24-3/4 115 Volts/20 Amps Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 36 x 84 x 24-3/4 115 Volts/20 Amps Approx. shipping wt. (lbs.) 675 • 21.9 cu. ft. capacity • Four-point leveling system • 130° door stop • Coil-free back • Flush or trimmed (semi-flush) installation • Trimmed models require door and grille panels • Trim kit required for 3/4" trimless panels, custom handles or installation heights of 83-1/2" or 84-1/2". • Door swing preference must be specified • Unified grille kits for installation with 3/4" custom panels or stainless steel models • 21.9 cu. ft. capacity • Four-point leveling system • 130° door stop • Coil-free back • Automatic icemaker • Flush or trimmed (semi-flush) installation • Trimmed models require door and grille panels • Trim kit required for 3/4" trimless panels, custom handles or installation heights of 83-1/2" or 84-1/2". • Door swing preference must be specified • Unified grille kits for installation with 3/4" custom panels or stainless steel models *Stainless steel-wrapped doors *Stainless steel-wrapped doors 20 675 monogram.com The installation space B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in custom all-refrigerators and all-freezers Product dimensions 24-3/4" Electrical Outlet Location 2-1/2" Case Depth: 24-3/4" B A = 36", B = 35-1/2" for semi-flush and 36" for flush installations. 83-1/2" To 84-1/2" 5" Note: Icemaker Water Connection Is At The Front Of The Freezer Water Supply 5" A 3-1/2" Depth Including Handles: 26-1/4" Framed Models 26-3/4" Stainless Steel Models 3-1/2" Electrical A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown. 696Dia10 605Dia29 Door swing clearances The installation must allow for clearances to adjacent walls or cabinets. These refrigerators are factory set for a 130° door swing. The door swing can be reduced to as little as a 90° opening with an optional WX14X99 kit. The serial plate is located inside the refrigerator/freezer below the bottom storage drawer on the right side. Note: GFI (ground fault interrupter) is not recommended. Water line The water line can enter the opening through the floor or back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the front of the freezer. The installation of an easily accessible shut-off valve in the water line is required. Leveling The rear leveling wheels and front leveling legs are limited to a maximum height adjustment of 1". Side-by-side installations When installing an all-refrigerator and all-freezer side by side, the installation space must be 71-1/2" wide. • Locate water and electrical as shown. • A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product. 71-1/2" Finished Width 2-1/2" 28-1/2" Electrical Wall View 6" 5" 5" 84-1/2" max 83-1/2" min Finished Opening 24" Cutout Depth 75" From Floor to Bottom of Electrical Area 5" Water Supply 3-1/2" *Shipping height. Cabinet height may be changed to 83-1/2" or 84-1/2" using ZGC2 grille panel kit. The ZKTR36 kits for 3/4" thick panels provide a grille panel support for all heights. 130° Door Swing 25" Min. to Wall B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers 24-3/4" Total Depth *84" 75" From Floor to Bottom of Electrical Area 90° Door Swing 36-3/4" 130° 90° door swing with optional WX14X99 door stop. 605Dia20 Free -standing side - by-side refrigerators 5" B u i l t- i n b o t t o m - f r e e z e r refrigerators 6" 4" Min. to Wall • Allow 25" minimum clearance for a full 130° door swing. Allow 15" for pan removal. 605Dia32 • 4" minimum clearance is required when the door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted. Clearances for multiple installations When installing an all-refrigerator and all-freezer side by side, allow 25" for a full 130° door swing, or 15" min. on the hinge sides for pan removal. 0" 25" 25" Min. to Min. to Wall Wall 130° Door Swing 130° Door Swing 26" Freezer Refrigerator 21 696Dia12 Advance planning for built-in custom all-refrigerators and all-freezers Customization basics: Framed or overlay panels, custom handles and accessory kits These Monogram® all-refrigerators and all-freezers may be installed flush or semi-flush with surrounding cabinetry. Cutout dimensions, clearances and side panel sizes are determined by the many installation options available. The all-refrigerator and all-freezer models are factory set for a left or right door swing. The door swing is NOT reversible. Choose an RH model with hinge on the right side; the door swings left to right. Choose an LH model with hinge on the left side; the door will swing right to left. Stainless steel–wrapped all-refrigerators ZIRS36NMLH, ZIRS36NMRH Stainless steel–wrapped all-freezers ZIFS36NMLH, ZIFS36NMRH Stainless steel–wrapped models have tubular stainless steel handles that coordinate with other Monogram appliances. These models do not accept custom panels or custom handles. However, you may wish to change the installation height or use a side-by-side kit. Custom all-refrigerators ZIR36NMLH, ZIR36NMRH Custom all-freezers ZIF36NMLH, ZIF36NMRH Custom all-refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required. Use one or more kits to accomplish a wide range of appearance options. Trim kits must be ordered separately from your Monogram supplier. See trim kit descriptions at right. Framed panels You may install a 1/4"-thick custom panel from your cabinet manufacturer. The decorative panel slides into the factoryinstalled trim. Black Lexan® and stainless steel accessory panels are available from your Monogram dealer. 3/4" trimless panels You may also choose to install a 3/4" custom overlay panel from your cabinet manufacturer. This design provides a seamless appearance which integrates smoothly with surrounding cabinetry. A trim kit is required for a 3/4" custom panel. Door handles The supplied handle can be replaced with a custom handle of your choice on both 1/4" and 3/4" panels. The Monogram tubular stainless steel handle is also available to fit the chosen panel thickness. Custom handles should be supplied by your cabinetmaker. Trim kits are required to support a custom handle. 22 Optional trim kits Door handle kits ZKHR1: Provides the necessary framework to install a custom handle of your choice onto a 1/4"-thick custom panel. (Handle not included.) ZKHTR1: Provides the necessary framework to install a custom handle of your choice onto a 3/4"-thick custom panel. (Handle not included.) This kit must be used in combination with ZKTR36LH or ZKTR36RH. ZKHRSS1: Tubular stainless steel handle for 1/4"-thick panel installation. ZKHTRSS1: Tubular stainless steel handle for 3/4"-thick panel installation. This kit must be used in combination with ZKTR36LH or ZKTR36RH. Custom panel kits ZKTR36LH for ZIR36NDLH, ZIF36NDLH ZKTR36RH for ZIR36NDRH, ZIF36NDRH Provides for the installation of 3/4" thick custom door and grille panels. Use this kit for a trimless appearance. This kit includes a standard handle to fit the 3/4" thick panel. Height adjustment kit ZGC2: Provides 1/4" grille panel frame side pieces for 83-1/2" and 84-1/2" installation heights. (The supplied grille panel frame is set for 84" installation height.) Side-by-side kit ZUG75: For side-by-side installation of two trimmed units. This kit provides for the installation of a 3/4" unified custom grille panel to span the width of two units. Includes a trim strip to cover inside case trim for a finished appearance. This kit must be used in combination with BOTH the ZKTR36LH and ZKTR36RH custom panel kits. ZUGSS side-by-side grille panel kit For installation of two stainless steel units. This kit provides a unified stainless steel grille panel to span the width of two units. It includes a trim strip to cover the inside case trims for a finished appearance. Accessory panels Black Lexan and stainless steel accessory panels are available from your Monogram supplier. Panels are cut to size and ready to install. These panel kits must be ordered separately. Black Stainless steel ZWBR36ZWSR36 monogram.com B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for built-in custom all-refrigerators and all-freezers Custom panel dimensions A Height Rout for 3/4" Handle Kits Only See Details Custom door panel sizes SIZES A 1/4" panels35-1/16" 3/4" panels35-1/16" 3/4" panels with custom handle35-1/4" 605Dia37 3/4" grille panel dimensions Order ZKTR36LH or ZKTR36RH panel kit. A grille panel support is included with this trim kit and fits all installation heights. B 68-7/8" 68-15/16" 3/4" custom grille panel Panel width Panel height to fit installation height 83-1/2" 84" 84-1/2" 35-1/4" 7-3/4" 8-1/4" 8-3/4" 605Dia39 68-15/16" For Handle Kits Only Rout Back Side of Panel 1-13/16" 1/4" Max. Width Custom Grille Panels B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers B 1/4" custom grille panel Panel width Panel height to fit installation height 83-1/2" 84" 84-1/2" 35-1/8" 7-1/2" 8" 8-1/2" Appearance Side Rout the back side of the custom panel when installing a ZKHTR1 custom handle kit or ZKHTRSS1 tubular stainless steel handle kit. ZUG75 grille panel dimensions The ZUG75 grille panel kit should be used in combination with both the ZKTR36LH and ZKTR36RH panel kits. 3/4" custom grille panel Panel width Panel height to fit installation height 83-1/2" 84" 84-1/2" 71-3/8" 7-3/4" 8-1/4" 8-3/4" Free -standing side - by-side refrigerators Custom Panel Important note: Maximum weight for door panel is 67 pounds and 9 pounds for the grille panel. 1/4" custom grille panel dimensions The supplied grille panel frame is factory-assembled for 84" installation height. Order ZGC2 grille panel kit when installation height is more or less than 84". B u i l t- i n b o t t o m - f r e e z e r refrigerators Framed and 3/4" trimless panel dimensions If you choose to install framed or 3/4" trimless panels, they must be cut to the dimensions shown. Width ZUG75 Grille Panel Height Important: Grille panel maximum total weight is 18 lbs. 605Dia38 605Dia40 23 Free-standing stainless steel—wrapped refrigerators General features Allover stainless appearance. At once dramatic and restrained, Monogram® stainless steel–wrapped refrigerators are smooth from edge to edge, with no exposed screws or rivets. For a built-in look, choose the counter-depth model, which aligns nearly flush with surrounding cabinetry. Climate-control drawer. Functions like a refrigerator within the refrigerator. Precise controls allow you to expresschill beverages, express-thaw meats and select specific temperatures for perishable foods. Extra-tall dispenser. Accommodates glassware of all sizes, from pitchers to tumblers. Energy Star® qualified. As an Energy Star partner, GE has determined that these freestanding refrigerators meet the Energy Star guidelines for energy efficiency. SmartWater™ filtration system. Delivers clean, greattasting water and ice through the dispenser. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 24 QUICK QUICK ICE ICE RESET WATER RESET FILTER WATER DOOR CONTROL FILTER DOOR ALARM CONTROL LOCK ALARM LOCK 36" free -standing ZFSB25DMSS.EPS side -by-side refrigerator 36" free -standing ZFSB25DMSS.EPS side -by-side counter- depth refrigerator 36" free -standing side -by-side counter- depth refrigerator ZFSB26DRSS ZFSB23DRSS ZFSB25DTSS Overall dimensions (WxHxD in inches): 36 x 72 x 34 (including handles) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 490 Overall dimensions (WxHxD in inches): 36 x 72 x 29-1/2 (including handles) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 460 Overall dimensions (WxHxD in inches): 36 x 72 x 30-1/2 (including handles) 115 Volts/20 Amps Approx. shipping wt. (lbs.) 493 • 25.5 cu. ft. capacity • Energy STAR qualified • Concealed door hinge • 22.6 cu. ft. capacity • Energy STAR qualified • Concealed door hinge • 24.6 cu. ft. capacity • Energy STAR qualified • Full height doors • Concealed door hinge monogram.com B u i l t- i n s i d e - b y - s i d e refrigerators Advance planning for free-standing refrigerators Door swing clearances Product dimensions 32" (34" Including Handles) 27-1/2" (29-1/2" Including Handles) The installation must allow for clearances to adjacent walls or cabinets. These refrigerators are factory set for a 160° door swing. ZFSB26, ZFSB25 and ZFSB23 14-1/4" 19" 160° Door Swing B u i l t- i n b o t t o m - f r e e z e r refrigerators 72" 72" 36" 36" 160° zfsb26dRss zfsb23dRss 28-1/2” Depth (30-1/2" Including Handles ZFSB26 ZFSB25 ZFSB23 605Dia43 28" 24-5/8" 24" 22" 22" B u i l t- i n a l l - r e f r i g e r a t o r s and all-freezers 90° Door Swing 22" 72" 4" Min. to Wall zfsb25dTss Installation note: Door and passageways into the installation location require a 36" minimum opening. If the opening is less than 36", the top cap and doors must be removed. See installation instructions for details. 605Dia44 • 4" minimum clearance is required when the door swing is restricted to 90°. Free -standing side - by-side refrigerators 36" Allow 19" minimum clearance on the fresh food side for a full 160° door swing and pan removal. Allow 14-1/4" clearance on the freezer side for removal of ice bin. Air circulation clearances Allow 1/8" on each side and 1-1/2" at the top and back side for proper air circulation. Electrical A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. This serial plate is located inside the fresh food compartment, at the top and on the right side. Note: GFI (ground fault interrupter) is not recommended. Water line The water line can enter the opening through the floor or back wall. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the rear of the refrigerator. The installation of an easily accessible shut-off valve in the water line is required. 25 Custom options for refrigerators 48" side-by-side refrigerators Models Custom options ZISW480DR Glossary of terms ZISB480DR ZIS480NR Stainless steel tubular handles for overlay panelsZKHSS2ZKHSS2ZKHSS2 1/4" black acrylic panelsZPB480DZPB480N 1/4" stainless steel panelsZPS480DZPS480DZPS480N Tubular stainless steel handles. Monogram® stainless steel tubular handles can be used with custom panels. 42" side-by-side refrigerators Models Custom options ZISW420DR ZISB420DR ZIS420NR Stainless steel tubular handles for overlay panelsZKHSS2ZKHSS2ZKHSS2 1/4" black acrylic panelsZPB420DZPB420N 1/4" stainless steel panelsZPS420DZPS420DZPS420N 36" side-by-side refrigerators Models Custom options ZISW360DR ZISB360DR ZIS360NR Stainless steel tubular handles for overlay panelsZKHSS2ZKHSS2ZKHSS2 1/4" black acrylic panelsZPB360DZPB360N 1/4" stainless steel panelsZPS360DZPS360DZPS360N 36" bottom-freezer refrigerators Models ZIC360NRRH ZIC360NRLH Custom options Stainless steel tubular handles for overlay panelsZKHCSS2ZKHCSS2 ZICS360NRRH ZICS360NRLH Unified grille kitZUG2ZUG2ZUGSS2ZUGSS2 1/4" black acrylic panelsZPBC360ZPBC360 1/4" stainless steel panelsZPSC360ZPSC360 Custom handle side trim kit for 3/4"-thick custom panelsZKHCTZKHCT 36" all-refrigerators and all-freezers Models All-refrigerators All-freezers Custom options ZIR36NMRH ZIF36NMRH ZIR36NMLH ZIF36NMLH ZIRS36NMRH ZIFS36NMRH ZIRS36NMLH ZIFS36NMLH Stainless steel panels ZWSR36ZWSR36 Black Lexan panels ZWBR36ZWBR36 Custom handle kit for framed 1/4"-thick panelsZKHR1ZKHR1 Tubular stainless steel handles for 1/4"-thick panelsZKHRSS1ZKHRSS1 3/4"-thick custom panel kitZKTR36RHZKTR36LH Custom handles for overlay 3/4"-thick custom panelsZKHTR1ZKHTR1 Tubular stainless steel handles for 3/4"-thick custom panelsZKHTRSS1ZKHTRSS1 Adjustable grille height kitZGC2ZGC2 Unified grille panel kit for side-by-side installationZUG75ZUG75ZUGSSZUGSS 26 Stainless steel or black panels. Factory-installed trim will accept 1/4"-thick accessory panels which are cut to size and ready to install. These panels must be ordered separately. Unified grille panel kit. An optional grille panel creates a unified look above two units placed side by side. Optional Sabbath mode product kit. Designed for use on the Jewish Sabbath and holidays, this kit allows the refrigerator to operate but will not respond to actions by the consumer. This kit is available for use on builtin side-by-side and bottom freezer refrigerators only. monogram.com Refrigeration modules Double - drawer refrigerator Double - drawer refrigerator general features Temperature control. Digital touch controls maintain a consistent temperature for the upper and lower drawers, and an LED display allows you to monitor the temperature at a glance. Interior lighting. Brilliant full-width LED lighting in both drawers puts contents into clear view. Flush installation. The built-in configuration allows nearseamless integration with surrounding cabinetry. Model ZIDI240PII accepts custom 3/4" panel and handle for a personalized look. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. Fr e s h - f o o d r e f r i g e r a t o r bar refrigerator Storage convenience. A fold-down shelf, adjustable dividers and removable bottom-drawer bin maximize storage space and flexibility, allowing room for everything from whole melons to large turkeys. The top drawer can hold up to 72 twelve-ounce cans, and the bottom drawer has room for eight two-liter bottles. Double - drawer ZIDS24OPSS refrigerator ZIDS240PSS—Stainless steel ZIDI240PII—Custom panel Overall dimensions* (WxHxD in inches): 23-3/4 x 34-1/4 - 34-3/4 x 23-3/4 Amps @120 Volts 15 Approx. shipping wt. (lbs.) 126 O u t d o o r/ i n d o o r refrigerator • Designed to be built-in only. Cannot be used free-standing • Factory-installed black toekick, stainless toekick included • Trimmed model designed to be customized with custom panel and handle • Both designs can be installed flush in standard 24” deep cabinets W ine re se r ve, wine c hille r b eve rage ce nte r *Height excluding legs, depth excluding handle Advance planning for double-drawer refrigerator The installation space Locate Outlet The Monogram® double-drawer refrigerator must be installed below a countertop. It cannot be used free-standing. Note: When installed, model ZIDI240PII with 3/4" custom drawer panels and model ZIDS240PSS with stainless steel wrapped drawers will be flush with adjacent 24"-deep cabinets. 10-1/2" 34-1/2"-35" 9" Max. 1-1/2" 23-3/4" Min. 24" Min. 23-3/4" Stainless Steel Models 24-7/8" Framed Models Depth Including Handles: 25-7/8" Stainless Steel Models Only 34-1/4" - 34-3/4" 23-3/4" 27 Advance planning for double-drawer refrigerator Location requirements All Monogram® refrigeration modules may be closed in on the top and sides as long as the front is unobstructed for air circulation. • Do not install these products where the temperatures will go below 55°F (13°C) or above 90°F (32°C). • Docustom not installpanels where they 3/4" for will be subject to direct sunlight, heat or moisture. fresh food and bar refrigerator • These products are not designed to be stacked one over the other. Electrical A 120V, 60HZ., 15 or 20 amp power supply is required. An Overlay Panel circuit or circuit breaker individual properly grounded branch Overlay Panel is recommended. Install a properly grounded 3-prong electrical Door receptacle recessed into the back Spacer Panelwall of the installation opening. See cutout illustration. Panel The serial plate is located Backer below the bottom drawer liner on 1/4" the left side. .10 Inch Backer Spacer Panel Note: GFCI (ground fault circuit interrupter) is not recommended. 3/4" custom panels for double - drawer refrigerator Field-installed overlay drawer panels are required for model ZIDI240PII. • T he overlay panel must be secured to a 1/4"-thick backer 3/4" panel custom that slidespanels into the for drawer trim. A .10"-thick spacer panel must placed the overlay and backer panel. fresh foodbeand barbetween refrigerator 3/4" custom panels for • Custom handles of your choice must be installed onto the double drawer refrigerator assembled overlay panels. Overlay Panel Overlay Panel Overlay Panel Spacer Panel Door Overlay Panel Door 1/4" Backer Panel 1/4" Backer Panel O Door Spacer Panel Backer Panel .10 Inch Spacer Backer Panel Maximum assembled panel weight is 25 lbs. (12-1/2 lbs. for each panel) .10 Inch Spacer For the ultimate in convenience, install two double-drawer refrigerators together. • Products must operate from separate properly B grounded receptacles. A A 12-1/2 lbs. max. B A 1/4" Gap 12-1/2 lbs. Note: Maintain 1/4" gap between the drawer panels. 1/ Assemble overlay panels with glue and screws. •C enter spacer panel on the backer panel, left to right, and top Route to bottom. Secureforthe panels with glue. hinge 3/4 clearance Route for hinge clearance 3/8 Front 28 Right side view of overlay custom panel Front •C enter the Topoverlay panel. Secure 3/4spacer/backer panel on the with glue and screws. Countersink allview screws. Top view of overlay custom panel 3/8 Front 3/8 7/8 Route for hinge clearance Right side view of overlay custom panel . B (height) 14-11/16" 14-3/16" 15-1/16" A (width) 1/4" backer 23-3/16" 0.10" spacer 22-1/2" 3/4" overlay 23-5/8" B 12-1/2 lbs. max. B 1/4" Backer Panel A 3/4" overlay panel dimensions (in inches) Side -by-side installation 3/4" cust double d Front of overlay custom panel 3/8 7/8 Route for hinge clearance 12-1/2 lbs. monogram.com Refrigeration modules Double - drawer refrigerator Fresh-food refrigerator general features Temperature control. Digital touch controls offer a range of temperatures for precise chilling of a variety of fresh foods and beverages, and an LED display allows easy viewing of temperatures. Flexible installation. Both the right-hand and left hand door swing models stand beautifully on their own, or may be built into cabinetry. Models ZIFI240PII and ZIFI240PLII accept a custom 3/4" panel and handle for a personalized look. Fresh-food ZIBS240PSS Head On refrigerator Bar refrigerator ZIBS240PSS Head On with icemaker Bar refrigerator with icemaker general features Right-hand door swing ZIFS240PSS—Stainless steel ZIFI240PII—Custom panel ZIBS240PSS—Stainless steel ZIBI240PII— Custom panel Automatic icemaker. Self-contained icemaker features a removable ice bin on full-extension slides and a heavy-duty ice scoop for serving convenience. Left-hand door swing ZIFS240PLSS—Stainless steel ZIFI240PLII—Custom panel Flexible installation. The free-standing bar refrigerator stands beautifully on its own, or may be built into cabinetry. Model ZIBI240PII accepts custom 3/4" panel and handle for a personalized look. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. Advance planning for fresh-food refrigerator and bar refrigerator with icemaker • Built-in or free-standing installation • Factory-installed black toekick, stainless toekick included • Trimmed model designed to be customized with custom panel and handle • Right-hand or left-hand door swing models for installation flexibility Overall dimensions* (WxHxD in inches): 23-3/4 x 34-1/4 - 34-3/4" x 23-3/4 Amps @120 Volts 15 Approx. shipping wt. (lbs.) 126 • Built-in or free-standing installation • Factory-installed black toekick, stainless toekick included • Trimmed model designed to be customized with custom panel and handle • Right-hand door swing only O u t d o o r/ i n d o o r refrigerator Storage convenience. Beverage shelf on full-extension slides holds up to five wine bottles or ten 12-oz. cans, while spillproof glass shelves provide ample space for fresh foods and beverages. Overall dimensions* (WxHxD in inches): 23-3/4 x 34-1/4 - 34-3/4" x 23-3/4 Amps @120 Volts 15 Approx. shipping wt. (lbs.) 126 ZIFS240PSS W ine re se r ve, wine c hille r b eve rage ce nte r Temperature control. Digital touch controls allow a range of temperature settings for different cooling needs, and an LED display makes settings clearly visible. ZIFS240PSS Fr e s h - f o o d r e f r i g e r a t o r bar refrigerator Storage convenience. Removable, spillproof glass shelves, along with a QuickSpace™ shelf and a clear Lexan® crisper on full-extension slides, provide easy access to contents. *Height excluding legs, including hinge; depth excluding handle The installation space The Monogram fresh-food refrigerator and bar refrigerator with icemaker may be installed beneath a countertop or can be used free-standing. • If installing between frameless cabinets, a 1/2"-wide filler strip or side panel may be required. The filler strip will act as a spacer between the door case and adjacent cabinet and will prevent interference with cabinet door swing. The width of the opening must include filler panels. Note: When installed, the stainless steel models ZIFS240PSS and ZIBS240PSS will be flush with adjacent cabinetry. If installing between frameless cabinets, a 1/2" wide filler strip or side panel may be required to prevent interference with cabinet door swing. Models ZIFI240PII and ZIBI240PII will project forward 1-3/4" of adjacent 24"-deep cabinets. 34-1/2" to 35" Locate Outlet 10-1/2" Water and 24" Min. Electrical 9" Locations Max. 23-3/4" Stainless Steel Models 1/2" 24-7/8" Framed Models 1-1/2" 23-3/4" Min. Depth Including Handle: 26" Stainless Steel Models Only 34-1/4" - 34-3/4" 23-3/4" 29 Advance planning for fresh-food refrigerator and bar refrigerator with icemaker Location requirements All Monogram® refrigeration modules may be closed in on the top and sides as long as the front is unobstructed for air circulation and door swing. • Do not install these products where the temperatures will go below 55°F (13°C) or above 90°F (32°C). • Do not install where they will be subject to direct sunlight, heat or moisture. • These products are not designed to be stacked one over the other. Electrical A 120V, 60HZ., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall of the installation location. See cutout illustration. Note: GFCI (ground fault circuit interrupter) is not recommended. Water line Bar refrigerators are equipped with an automatic icemaker. The water line can enter an opening in the back wall or floor as shown in the cutout illustration. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location. The installation of an easily accessible shut-off valve in the water line is required. 3/4" custom panels for fresh-food refrigerator and bar refrigerator with icemaker A field-installed overlay door panel is required for models ZIFI240 and ZIBI240 refrigerators. • The overlay panel must be secured to a 1/4"-thick backer 3/4" custom panels fordoor trim. A .10"-thick spacer panel panel that slides into the mustfood be placed the overlay and backer panel. fresh and between bar refrigerator 3/4" custom panels for • Custom handles of your choice must be installed onto the fresh food and bar refrigerator assembled overlay panel. •Z TBSS1 Monogram stainless steel tubular handle is available for models ZIFI240 and ZIBI240. Overlay Panel Overlay Panel Door Overlay Panel Door 1/4" Backer Panel 1/4" Backer Panel Door Overlay Panel Spacer Panel Spacer Panel Backer Panel .10 Inch Spacer Over Pan Backer Panel .10 Inch Spacer Maximum assembled panel weight is 25 lbs. 3/4" overlay panel dimensions (in inches) 1/4" backer 0.10" spacer 3/4" overlay B A (width) 23-3/16" 22-1/2" 23-5/8" B (height) 29-9/16" 29-1/16" 30" A Make the most of your kitchen space with two Monogram refrigeration modules installed together. Assemble overlay panels with glue and screws. • Products must operate from separate properly grounded receptacles. •C enter spacer panel on the backer panel, left to right, and top to bottom. Secure the panels with glue. Door swing clearances •C enter the spacer/backer panel on the overlay panel. Secure Route with glue and screws. for hinge Countersink all screws. All Monogram refrigeration modules are factory set for a 110° door swing. When installed in a corner: • Allow the minimum door swing clearances shown. The use of a custom panel and custom handle influences the minimum clearances required. • The minimum clearance shown at 90° will allow full extension of drawers and shelves. Right-hand door swing shown. Allow the same clearances for left-hand models on the opposite side. A Minimum to Wall 90° Door Swing 110° Door Swing 21-5/8" A clearance Top Route view Use a 3/4" router bitfortohinge cut a notch into the back side of the of clearance Top the notch 3/4" deep, assembled3/4 panel3/8for hinge clearance. Cut overlay view 7/8" wide and side. custom Right3/8" forward of the back Front Front panelof side 3/8 overlay view custom 3/8 ofRight Front Front panel side overlay view custom Route 7/8 3/8 for hinge panelof overlay clearance Note: Right-hand custom models illustrated. Route 7/8 for hingeon the panel Cut notches clearance opposite side for left-hand door swing. Custom 3/4 panel hinge routing 23-5/8" 110° 90° B Minimum to Wall 30 Models ZIFS240 / ZIBS240 ZIFI240 / ZIBI240 A 14" 16" B 4" 4-1/2" O Door B Side -by-side installation 3/4" custom double draw 3/4" cust double d The serial plate is located on the inside ceiling of the fresh-food refrigerators, and on the left wall below the ice compartment of the bar refrigerators. 1/4" .10 I Backer Spa Panel 1/4" . Backer Panel A 12-1/2 lbs. max A 12-1/2 lbs. 12-1/2 lbs. max 1/4" G 12-1/2 lbs. 1/ monogram.com Refrigeration modules Double - drawer refrigerator Outdoor/indoor refrigerator general features Outdoor design. Sturdy, professional-grade stainless steel exterior stands up to the most demanding environmental conditions. Temperature control. Digital touch controls help keep foods fresh, regardless of outdoor temperatures. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. Right-hand door swing ZDOD240PSS—Stainless steel Left-hand door swing ZDOD240PLSS—Stainless steel Overall dimensions* (WxHxD in inches): 23-3/4 x 34-1/4 - 34-3/4 x 23-3/4 Amps @120 Volts 2 Approx. shipping wt. (lbs.) 154 O u t d o o r/ i n d o o r refrigerator Flexible installation. Finished on all sides in stainless steel, the Outdoor/Indoor Refrigerator allows a wide range of installation possibilities outside and inside your home. Both the right-hand and left-hand door swing models stand beautifully on their own or for even more flexibility, the top panel can be removed to allow built-in installation. Outdoor/indoor ZDOD240PSSHO refrigerator • Built-in or free-standing installation • Vented stainless steel toekick • Door lock and two keys • Stainless steel top canopy is removable for built-in installation • Vinyl covers for built-in and freestanding installations • Stainless Steel Magic and polishing cloth • Right-hand or left-hand door swing models for installation flexibility W ine re se r ve, wine c hille r b eve rage ce nte r Door lock. Helps prevent unwanted access, ensuring the door remains closed. Fr e s h - f o o d r e f r i g e r a t o r bar refrigerator Storage convenience. Two removable glass shelves, along with a QuickSpace™ shelf and two full-extension beverage shelves, allow flexible storage of fresh foods, drinks and condiments. *Height excluding legs, including hinge; depth excluding handle 31 Advance planning for outdoor/indoor refrigerator The installation space Door swing clearances The Monogram® outdoor/indoor refrigerator may be installed beneath a countertop or can be used free-standing. The top canopy can be removed for installation below a countertop. All Monogram refrigeration modules are factory set for a 110° door swing. • If installing between frameless cabinets, a 1/2"-wide filler strip or side panel may be required. The filler strip will act as a spacer between the door case and adjacent cabinet and will prevent interference with cabinet door swing. The width of the opening must include filler panels. Note: When installed, the door should project forward 1-1/2" of adjacent 24"-deep cabinets. When installed in a corner: • Allow the minimum door swing clearances shown. • The minimum clearance shown at 90° will allow full extension of drawers and shelves. A 15" Minimum totoWall Minimum Wall 110° Door Swing 90° Door Swing Locate Outlet 10-1/2" 34-1/2" Min. 9" Max. 23-5/8" 24" Min. 1-1/2" 23-3/4" Min. 110° 23-3/4" 34-1/4" - 34-3/4" (36"with top canopy) 26-1/2" Including Handle 23-3/4" Location requirements All Monogram refrigeration modules may be closed in on the top and sides as long as the front is unobstructed for air circulation and door swing. • The outdoor/indoor refrigerator may be operated in an environment where the temperatures are 45°F (7°C) to 120°F (49°C). • Do not install where it will be subject to direct sunlight, heat or moisture. • These products are not designed to be stacked one over the other. Electrical A 120V, 60HZ., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall as shown. This product must be connected to a power source with Ground Fault Circuit Interrupter (GFCI) protection when installed in an outdoor location. Local codes may require a separate circuit. The serial plate is located on the inside ceiling. 32 21-5/8" Right-hand door swing shown. Allow the same clearances for left-hand models on the opposite side. 90° B 5-1/4" Minimum to Wall Minimum Wall monogram.com Double - drawer refrigerator Refrigeration modules ZDWT240PBS ZDWI240WII ZDWR240PBS ZIWI240WII zdwc240 zdwr240 ZDWC240NBS zdwc240 zdwr240 Fr e s h - f o o d r e f r i g e r a t o r bar refrigerator Wine reser ve, wine chiller ZDWT240PBS–Privacy glass ZDWI240WII–Custom frame door ZDWR240PBS–Digital controls ZDWC240NBS–Dial controls Wine reser ve with privacy glass general features Wine chiller with dial control general features Privacy glass. Innovative liquid-crystal technology allows you to turn glass from translucent to transparent with a simple press of a button. Opaque setting conceals contents from view. Temperature control. Adjustable thermostat can maintain the ideal temperature for aging or serving, with a temperature range from the mid-40s to mid-60s Fahrenheit. Wine reser ve with custom door frame general features Customization. A custom door and handle are required. The custom frame surrounds the tempered, UV-resistant glass door. O u t d o o r/ i n d o o r refrigerator *Height excluding legs, including hinge; depth excluding handle • Built-in or free-standing installation • Factory-installed black toekick, stainless toekick included • Unfinished cherry wood shelf fronts can be customized Storage convenience. Full-extension sliding racks store up to 57 wine bottles and keep them close at hand. Flexible installation. The free-standing wine chiller may be built into cabinetry. W ine re se r ve, wine c hille r b eve rage ce nte r Overall dimensions* (WxHxD in inches): 23-3/4 x 34-1/4 - 34-3/4 x 23-3/4 Amps @120 Volts 15 Approx. shipping wt. (lbs.) 172 Wine reser ve with digital controls general features Temperature control. Digital touch controls allow you to select precise temperature settings, which are essential for proper wine storage. Storage convenience. Full-extension sliding racks store up to 57 wine bottles and keep them close at hand. Flexible installation. The free-standing wine reserve may be built into cabinetry. 33 Refrigeration modules ZDBT240PBS ZDBI240WII zdbc240 ZDBR240PBS zdbr240 ZIBI240WII ZDBC240NBS zdbc240 zdbr240 Beverage centers ZDBT240PBS–Privacy glass ZDBI240WII–Custom frame door ZDBR240PBS–Digital controls ZDBC240NBS–Dial controls Overall Dimensions* (WxHxD in inches): 23-3/4 x 34-1/4 - 34-3/4 x 23-3/4 Amps @120 Volts 15 Approx. shipping wt. (lbs.) 146 *Height excluding legs, including hinge; depth excluding handle • Built-in or free-standing installation • Factory-installed black toekick, stainless toekick included • Unfinished cherry wood shelf fronts can be customized Beverage center with privacy glass general features Beverage center with dial control general features Privacy glass. Innovative liquid-crystal technology allows you to turn glass from translucent to transparent with a simple press of a button. Opaque setting conceals contents from view. Temperature control. A range of temperature settings allows you to maintain the ideal climate for your beverages of choice. Wine reser ve with custom door frame general features Customization. A custom door and handle are required. The custom frame surrounds the tempered, UV-resistant glass door. Beverage center with digital controls general features Temperature control. Digital touch controls provide precise temperature settings for cooling of all types of beverages. Storage convenience. Three removable glass shelves, including a QuickSpace™ shelf, and two full-extension wine racks hold up to 10 wine bottles, as well as 12-oz. cans, quart-size bottles, and two-liter plastic containers. Flexible installation. The free-standing beverage center may be built into cabinetry. 34 Storage convenience. Three removable, spillproof glass shelves and two full-extension wine racks hold up to 12 wine bottles, as well as 12-oz. cans, quart-size bottles and two-liter plastic containers. Flexible installation. The free-standing beverage center may be built into cabinetry. monogram.com The installation space Reversible door swing The Monogram wine reserve and beverage centers may be installed beneath a countertop or can be used free-standing. Models ZDWI240WII, ZDWC240NBS, ZDWR240PBS, ZDBI240WII, ZDBC240NBS and ZDBR240PBS are shipped for a right-hand door swing. The door swing may be reversed, with no kits required. • If installing between frameless cabinets, a 1/2"-wide filler strip or side panel may be required. The filler strip will act as a spacer between the door case and adjacent cabinet and will prevent interference with cabinet door swing. The width of the opening must include filler panels. Note: When installed, the door should project forward 1" of adjacent 24"-deep cabinets. Custom framed models will project forward 1-3/4" of adjacent cabinets. Locate Outlet 10-1/2" 24-1/8" Framed models 23-3/4" Stainless steel models 34-1/4"34-3/4" 25-1/2" Including Handle Door swing clearances All Monogram refrigeration modules are factory set for a 110° door swing. When Installed in a corner: • Allow the minimum door swing clearances shown. 24" Min. 1-1/2" 23-3/4" Min. ZTBSS1 Monogram stainless steel tubular handle is available for models ZDWI240WII and ZDBI240WII. 23-3/4" Location requirements All Monogram refrigeration modules may be closed in on the top and sides as long as the front is unobstructed for air circulation and door swing. • Do not install these products where the temperatures will go below 55°F (13°C) or above 90°F (32°C). • The minimum clearance shown at 90° will allow full extension of drawers and shelves. A 10" Minimum to Minimum toWall Wall 90° Door Swing 110° Door Swing 21-5/8" O u t d o o r/ i n d o o r refrigerator 9" Max. Z TBSS1 Tubular handle 23-5/8" * 110° 90° *95° door swing on custom frame models. B 4" Minimum to Minimum to Wall wall Custom frame panel Models ZDWI240WII, ZDBI240WII require a custom panel frame surrounding the glass. There are two options, the panel may be 29-3/4" or 30". A 30" panel requires a notch cut into the bottom of the panel to avoid interference with the hinge. • Do not install where they will be subject to direct sunlight, heat or moisture. Note: A solid panel that covers the door glass CANNOT be installed on these models. • These products are not designed to be stacked one over the other. Option 1 Electrical A 120V, 60HZ., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall as shown. Electrical must be located on rear wall as shown. Note: GFCI (ground fault circuit interrupter) is not recommended. The serial plate is located on the inside ceiling. Option 2 23-1/8” 23-1/8” 2-1/4” wide, all sides Rout the back side of the opening 7/16”deep, 1-1/8” wide 2-1/4” 25-1/4” GLASS 29-3/4” 25-1/4” Route the back side of the opening 7/16” deep, 1-1/8” wide GLASS 30” 18-5/8” 18-5/8” 2-1/2” at bottom 3/4” Thick Custom Panel, Back Side 2-1/4” 1/8” 1/4” 2-1/4” Cut the notch 1/8” deep, 1/4” wide and 1/4” high For a complete refreshment center, install a Monogram wine reserve and beverage center together. Note: Right-hand models illustrated. Cut notches on the opposite side for left-hand door swing. • Products must operate from separate properly grounded receptacles. Choose Option 1 or Option 2 panel size depending on cabinetry size or style. Side -by-side installation W ine re se r ve, wine c hille r b eve rage ce nte r 34-1/2"-35" Privacy glass wine reserves and beverage centers have a right-hand door swing. They cannot be reversed. Fr e s h - f o o d r e f r i g e r a t o r bar refrigerator ® Double - drawer refrigerator Advance planning for wine reserves and beverage centers 1/4” 35 Automatic icemaker General features High production, large capacity. The icemaker produces up to 50 pounds of clear ice per day and automatically shuts off when the 25-pound-capacity bin is full. Customization. The 15" icemaker door accepts a 3/4" custom panel to match surrounding cabinetry. You can also add your own custom handle. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. Automatic icemaker ZDIS150WSS ZDIS150WSS, ZDIC150WBB, ZDIC150WWW Overall dimensions (WxHxD in inches): 14-13/16 x 34-1/2 x 23-5/16 Amps @ 115 Volts 5.3 Approx. shipping wt. (lbs.) 110 • Built-in or free-standing installation • Accepts 3/4" custom panels, requires kit • Reversible door swing, no kit required • Leveling system Advance planning for automatic icemaker The installation space The Monogram® icemaker may be installed free-standing or below a countertop. 34" to 34-1/2" 24" Min. Water and Electrical Supply Should Enter From Back Wall In Shaded Area. 3" 11-1/2" 9" *15" * 16-1/2" with a 3/4" thick custom panel Note: The addition of a 3/4"-thick custom panel will result in a front-to-back depth of 24-1/16". The icemaker cannot be installed flush to adjacent 24" deep cabinets with a 3/4"thick custom panel. 36 28-1/2" The installation of a 3/4” thick custom panel will require an additional 1-1/2” wide filler strip on the hinge side. 34" min. Adjustable to 34-1/2" 23-5/16" to Door Front 14-13/16" The serial plate is located on the left wall of the ice storage bin. Note: The installation of a 3/4"-thick custom panel will require an additional 1-1/2"-wide filler strip on the hinge side. The filler strip will act as a spacer between the icemaker case and adjacent cabinet. The filler strip will prevent interference with the icemaker door swing when it is installed between frameless or framed cabinetry. The width of the opening must include the filler strip. The icemaker may be closed in on the top and sides as long as the front is unobstructed for air circulation and proper access to the door. • Do not install these products where the temperatures will go below 55° (13°C) or above 110° (32°C). Electrical A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall as shown. Water line The water line can enter the opening through the back wall as shown. Route GE SmartConnect™ kit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the rear of the icemaker. The installation of an easily accessible shut-off valve in the water line is required. monogram.com Custom panel kits Door swing clearances Order ZIP75WW, white or ZIP75BB, black, 3/4" trimless custom panel kit. • Order the panel so that approximately 1/2" of the back side edge is finished. The back 3/4" Thick 29-1/2" edge of the panel will be visible Custom and therefore should be finished. Panel • Custom handles may be used with this kit. • A side filler panel may be 14-23/32" required on the hinge side to ensure a full door swing. The icemaker is factory set for a right-hinge door swing with the door swinging from left to right. The door swing may be reversed to a left-hinge swing. No kits required. • The installation must allow for clearances to adjacent walls or cabinets. The icemaker is factory set for a 110° door swing. 110° door swing 90° door swing WALL 21-1/2" Z TBSS1 Tubular handle 605Dia52 Monogram stainless steel tubular handle can be installed on the 3/4"-thick custom panel. 15-1/2" 90° 110° Drainage requirements 5-1/2" Minimum to Wall A method of drainage must be determined in advance. 3-1/2" High A u t o m a t i c i c e m a ke r s Advance planning for automatic icemaker 2" Minimum to Wall • Allow 5-1/2" minimum clearance on the hinge side for a full 110° door swing. 605Dia54 • 2" minimum clearance is required for access to the ice bin when the door swing is restricted to 90°. 605Dia53 Side View 7-1/2" 15" Locate Standpipe in exact Center of The Cutout Drain Hose 1" Min. Gap 3-1/2" 605Dia51 22" 22-3/4" With 3/4" Custom Panel • The ideal installation has a standpipe with a 2" to 1-1/2" PVC drain reducer installed directly below the outlet of the drain tube. The standpipe must be accurately located to prevent interference when sliding the icemaker into the opening. Maintain 1" gap between standpipe and icemaker drain hose. • The installation of a 3/4" custom door panel will influence the floor drain location. • When a floor drain is not located below the icemaker, order ZPK1 drain pump kit. This pump must be installed inside the unit and can pump to a maximum vertical height of 10 feet. The 10-ft. tubing is supplied with the kit. • The drain lines must be at least 5/8" inside diameter. 605Dia50 37 Compactors 15" compactor general features Fifteen-inch width. Fully integrated design with hidden controls, installs flush with surrounding cabinetry. Powerful pressure. Large 1.4 cu. ft. capacity. Reduces trash volume by 75 percent. Safe operation. A removable knob prevents unwanted use. The compactor foot pedal is used to both open the drawer and initiate operation, making it easy to use and convenient. Customization. For stainless steel model, order ZCGS150LSS. Model ZCGP150LII requires a 3/4" overlay panel and a custom handle. Shipped with both stainless steel and black toekicks. 12 " compactor general features Twelve-inch width. The slim design conserves space and permits attractive integration into cabinetry. Powerful pressure. Large 1.4 cu. ft. capacity. Reduces trash volume by 75 percent, allowing easy transport and disposal. Safe operation. A removable key locks the compactor, starts operation, and assures that the drawer remains locked during use. Customization. For stainless steel model, order ZCG3500DSS. White (ZCG3300VWW) and black (ZCG3100VBB) models also accept a 1/4" or 3/4" overlay panel and a custom handle. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 38 ZCGS150LSS 15" compactors 12" compactors ZCGS150LSS—Stainless steel ZCGP150LII—Custom panel ZCG3500DSS, ZCG3100VBB and ZCG3300VWW Overall dimensions (WxHxD in inches): 14-7/8 x 33-3/4 to 35 x 23 Amps @ 120 Volts Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 12 x 34 – 35 x 20-1/4 Amps @ 120 Volts Approx. shipping wt. (lbs.) • Large 1.4 cu. ft. capacity • Built-in installation only • Foot pedal open and start 5.0 141 • Large 1.4 cu. ft. capacity • Built-in installation only • No trim kits required for customization 5.0 135 monogram.com Advance planning for 15" compactors • The compactor is designed for built-in applications only. It cannot be operated free-standing. 24" min. Compactors This 15" wide Monogram® compactor offers a large 1.4-cu.- ft. capacity. 34" - 35" 15-1/8" min. Custom panel dimensions Install a 3/4" thick custom drawer panel and custom panel of your choice onto the ZCGP150LII. For planning purposes, you may order the template, Pub. No. 31-30597 in advance. The maximum panel weight is 12 lbs. 3/4" Thick Custom Panel 33-3/4" min. to 35" max. Locate the outlet 18" min. from the floor, 3" min. from either side. 24” case/ Clearances: Allow 6" door depth clearance to a vertical 26” including wall on the right side handle for bag removal. Allow 23" at the front for a full drawer opening. 29-5/16" 14-7/8 14-7/8" Advance planning for 12" compactors For an extra touch of convenience, Monogram built-in compactor fits in a neat 12" space. • This compactor is designed for built-in applications only. It cannot be used free-standing. • This compactor has an adjustable base which allows the toekick depth to be set to match adjacent cabinetry. 12-1/8" min. 34"-35" Note: Locate the outlet 18" min. from the floor, 3" min. from either side. Custom panel dimensions T he drawer trim on black and white models accepts 1/4" and 3/4" custom panels. No trim kits required. When a 3/4"-thick panel is used, the handle may be replaced with a custom handle of your choice. The drawer panel size varies depending on application. 24-1/2" 1/4" Custom Drawer Panel 24-3/4" 3/4" Custom Drawer Panel 25-13/16" 3/4" Custom Drawer Panel With Custom Handles 20-1/4" 12" 11-11/16" 34" min. adj. to 35" max. 22-1/2" min.* *Add 2-1/2" to depth if outlet is located directly behind compactor 12" 1/4"-thick custom panel Cut the panel to size and install. 3/4"-thick custom panel The custom panel should be constructed in the same manner as typical cabinet doors. Cut edges must be finished on all sides. The supplied handle may be replaced with a custom handle of your choice. 605Dia179 12" Adjustable base 2-3/4" to 4-1/4" 605Dia178 39 Dishwashers OFF HEAVY WASH NORMAL WASH LIGHT WASH CHINA CRYSTAL RINSE ONLY Fully integrated dishwasher Fully integrated dishwasher ZBD0710KSS ZBD6890KII.eps ZBD0710NSS Overall dimensions (WxHxD in inches): 24 x 34–35 x 24 Amps @120 Volts Approx. shipping wt. (lbs.) • Accepts custom toekick • Exterior end-of-cycle indicator light ZBD0700NII and ZBD6890NII 9.1 122 Fully integrated dishwasher Compact dishwasher ZBD6880 ZBD6880NSS, ZBD6800NWW and ZBD6800NBB ZBD1800GSS Overall dimensions (WxHxD in inches): 24 x 34–35 x 24* Amps @120 Volts 9.1 Approx. shipping wt. (lbs.) 117/115 Overall dimensions (WxHxD in inches): 24 x 34–35 x 24 Amps @120 Volts Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 17-1/2 x 32-1/2–35 x 22-1/2 Amps @120 Volts 12.0 Approx. shipping wt. (lbs.) 60 • A custom panel and handle are required • Accepts custom toekick • Accepts professional-style door/panel handle kit, ZPRO0700S • Accepts ZTB700 stainless steel tubular handle • Accepts custom toekick ZBD1800GSS.eps 9.1 120 • ADA-compliant installation below 34"-high countertops • Compact design • Two-piece adjustable toekick * 24-3/4" with custom panel (not including handle) General fully integrated dishwasher features Seamless style. The fully integrated design with concealed, top-mounted controls installs flush** with surrounding cabinetry for a dramatic, yet understated, effect. Ultraquiet operation. A quiet-engineered motor, extra-thick insulation and special sound-absorbing materials virtually eliminate the sound of washing dishes. Brilliant interior lighting. Used in headlights of highperformance automobiles, xenon technology provides superior light quality and brightness. (ZBD0710NSS and ZBD0700NII only) End-of-cycle indicator. Discreet lighting on the outside of the dishwasher lets you know when the cycle is complete and your dishes are clean and dry. (ZBD0710NSS only) Powerful, forced-air drying system. A fan-assisted, vented drying system extracts moist, warm air. Dishes come out dry, ready for the table or shelf. Complete cleaning coverage. Three direct-feed wash arms and six wash levels assure that every dish and utensil is sparkling clean. A three-stage filter system helps prevent food soils from being redeposited on dishes. 40 Extra-tall tub with towerless rack system. The generously sized interior provides the space and loading flexibility necessary to accommodate 16 place settings, with no wash tower to get in the way. The upper rack moves up, down and diagonally in one-inch increments, allowing maximal use of space above and below the rack. General compact dishwasher features (ZBD1800GSS) ADA-compliant. The compact configuration can be installed at a height that allows easy access. Easy-to-use controls. The mechanical dial turns easily to the desired wash cycle: heavy wash, normal wash, light wash, china, crystal or rinse only. Dual-motor, dual-wash-arm system. Two motors and wash arms provide effective, yet quiet, cleaning power. Nylon-coated racks. Durable racks provide plenty of space and loading flexibility. Lower rack includes a stem-safe shelf for odd-shaped items and delicate stemware. **Flush at 24" for black, white and stainless models; flush at 24-3/4" for custom panel models. monogram.com Advance planning for dishwashers dis h wa s h er s The installation space Monogram® dishwashers are designed for versatility, adaptable to virtually any installation. The rough cabinet opening must be prepared to the dimensions shown. • These dishwashers may be installed beneath countertops of stone or other materials that will not accept screws. • The dishwasher must be installed so that the drain hose is no more than 10 feet in length for proper drainage. Supplied or custom toekick • A two-piece toekick is supplied with model ZBD1800GSS. The toekick is height-adjustable. • Depending on cabinetry style, a custom toekick can also be installed to match cabinetry. Care must be taken to assure door swing clearance above the toekick. • Water and power supply should enter in the shaded area. • Electrical and water connections are at the right front of the dishwasher. The hot water line should extend forward 30" to 40" from the rear wall. The electrical must extend forward at least 24" to reach the junction box. • To prevent siphoning, an air gap must be used when the waste tee or disposer connection is less than 18" above the floor. ADA-compliant ZBD1800GSS: Installation below 34"-high countertops A reduced-height installation (32-1/2" min.) beneath a 34" countertop can be accomplished by adjusting the leveling legs and toekick. Electrical requirements Monogram 18" dishwashers cutout dimensions and clearances Monogram 24" dishwashers cutout dimensions and clearances 34" to 35" Underside of Countertop to Floor 17-5/8" Min. 18" Max. Floor MUST be Even with Room Floor. 24" Min. The dishwasher must be supplied with 120V, 60Hz, and connected to an individual properly grounded branch circuit protected by a 15- or 20-amp circuit breaker or time-delay fuse. 34-1/2" Min. Underside of Countertop to Floor Cabinets Square and Plumb This Wall Area must be Free of Pipes or wires 5" 4" 24" 5" 4" Min. Cabinets Square and Plumb 6" 24" Min. 32-1/2" Adjustable to 35" 22-1/2" Max. 17-1/2" 34" Adjustable to 35" Floor MUST be Even with Room Floor *Dishwasher models ZBD6890 and ZBD0700 require a 3/4" thick custom panel and will be 24-3/4" deep. (not including handle) *24" 24" ZBD0700Nll and ZBD6890Nll Fully integrated models with hidden controls. Require a 3/4" thick custom panel and a custom handle. ZBD0710NSS, ZBD6800NBB, ZBD6800NWW, ZBD6880NSS dishwashers. These models have a fully wrapped black, white or stainless steel door. 41 Advance planning for dishwashers Custom panels Custom accessories Custom panel for fully integrated models ZBD0700NII and ZBD6890NII These models require a field-installed 3/4" thick custom panel and custom handle. An installation template is packed with these models and may be obtained in advance. Order Pub. No. 31-30569-1. Complete panel installation instructions are included on the template. ZTB700 tubular handle Install this Monogram® stainless steel tubular handle onto your 3/4"-thick custom door panel. The handle is 22-1/2" wide and 1-1/8" deep. For models ZBD6890NII and ZBD0700NII only. Custom panel size requirements ZPRO0700S professional style door panel This panel provides a professional style handle on a stainless steel door panel. Transform the ZBD6890NII or the ZBD0700NII to complement a commercial-style kitchen. Standard flush installation • Models ZBD0700 and ZBD6890 dishwashers have a total depth of 24-3/4," including the required 3/4" thick door panel. They will install flush with cabinets that are 24-3/4" deep (including typical 3/4" thick cabinet doors). 30-1/16" Min. 30-1/4" Max. NOTE: Maximum door panel weight is 14 lbs. 23-3/4" HEIGHT: Panel height must be between 30-1/16" and 30-1/4" • If the panel height is more than 30-1/4", it will prevent the door from swinging open. • If the panel height is less than 30-1/16", it will not cover the dishwasher door frame. • The top of the custom panel must be flush with the top of the door. A 1/2" minimum gap between the top of the door and the bottom of the countertop must be maintained. WIDTH: Panel width must be 23-3/4" • If the panel width is less than 23-3/4", it will not cover the dishwasher frame. Heavy-duty springs Heavy-duty door springs are provided with the product. The springs must be installed to support the weight of a custom door panel or when installing the professional-style stainless steel door panel, ZPRO0700S. If needed, replacement door springs can be ordered. Order part number WD03X10023. 42 • Black, white and stainless steel dishwashers will install flush with 24" deep surrounding cabinetry. monogram.com General features Professional styling. Oversized range makes a bold culinary OFF BAKE CONV BROIL CLEAN OVEN statement in lustrous, professional-grade stainless steel. 48" p rof e s s ion al ran ges 48" dual-fuel professional ranges OVEN LIGHT GRILL OFF BAKE BROIL PROOF DOOR LOCKED HEATING OVEN OVEN LIGHT HEATING Sealed, dual-flame stacked burners. Two separate flames on each burner give you a range of precise temperatures, from a low 140°F simmer to a powerful 17,000-BTU* setting. The burners are sealed to the recessed cooktop subsurface for easy cleaning. Unique reversible grates. The individual burner grates one side and rounded on the other for grilling versatility. A Gourmet Radiant™ tray ensures even heat distribution, while reducing flare-ups. 18,000-BTU* griddle. The 3/8"-thick, stainless steel griddle is also sloped to offer a clean cooking surface. Thermostatic control ensures even heating and consistent results. Main oven (4.6 cu. ft., 27" wide)/ Companion oven (2.1 cu. ft., 12" wide). The large, self-cleaning convection oven offers two multipass broil and bake elements for even browning and baking. The companion oven is equipped with a single 6-pass broil element and 4-pass bake element. Self-clean oven racks. Heavy-duty, porcelain-coated racks are designed to remain in the main oven during the oven self-clean cycle for effortless cleaning. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. *15,000 BTU on liquid propane models. 36" professional ra n g e s 18,000-BTU* grill. The stainless steel surface is grooved on 48" professional range ZDP48N4GHSS ZDP48N4GHSS, ZDP48N6RHSS and ZDP48N6DHSS (natural gas) ZDP48L4GHSS, ZDP48L6RHSS and ZDP48L6DHSS (liquid propane) Overall dimensions (WxHxD in inches): 47-7/8 x 35-1/4– 36 -3/4 x 28-1/4 Amps @240VAC 41.0 208VAC 34.6 KW Rating @240VAC 9.8 208VAC 7.2 Approx. shipping wt. (lbs.) 640 30" professional ranges are flat on one side and uniquely contoured on the other to accommodate various size works. When positioned flat, the grates create a continuous cooking surface. • Dual-fuel range offers a combination of burners, grill and griddle on cooktop • Natural or LP gas must be specified by model number • Optional 12" or 22" backsplash accessories • All burner grates are reversible to support a round-bottom wok Advance planning for 48" professional ranges Professional ranges offer a number of choices in size and cooktop configurations. • All professional ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. Note: Conversion kits (WB49X10132, Natural to LP and WB49X10133, LP to Natural) are available if the wrong fuel type was ordered. High altitude kit, WB49X10130 (for Natural and LP gas models), is also available. This kit includes orifices for operation at 3,000 to 6,000 feet and another set for operation at 6,000 or more feet. Conversion kits must be installed by a qualified service technician at additional cost. Locate gas and electrical as shown. 12" Gas Supply Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 50-amp circuit for 48" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range. Gas supply • Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the range regulator. • The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the range regulator. 8" 4" 8" 4" Electrical requirements 16" 48" Electric Supply 1-1/2" 43 Advance planning for 48" dual-fuel professional ranges 48" range cooktop configurations Backsplash accessories The 48" professional dual-fuel ranges are available with a combination of grill, griddle and burners on top, a large electric convection oven and companion thermal oven. The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used. ZDP48N4GHSS with 4 burners, grill and griddle (Order ZDP48L4GHSS for LP gas) ZX12B48HSS, 12" backsplash ZX22B48HSS, 22" backsplash with warming shelf Backsplash with warming shelf All Monogram® professional wall mount hoods feature infrared warming lights. The 22"-high backsplash accessory with warming shelf is a perfect complement when installed with the tapered or straight-sided hoods. Restaurant-style professional hoods are shipped with a stainless steel backsplash and warming shelf. ZDP48N6RHSS with 6 burners and grill (Order ZDP48L6RHSS for LP gas) Side view with a backsplash 12" Min. to Combustibles or 0" Min. to Combustibles with 12" or 22" Backsplash 36" Min. to Combustibles ZDP48N6DHSS with 6 burners and griddle (Order ZDP48L6DHSS for LP gas) Backguard 0" Clearance Product dimensions and clearances A 54"- or 48"-wide professional vent hood with a minimum 1200 CFM is recommended for installation over this range. Optional h Backsplas The serial plate is located beneath the ledge trim, just above the left knob. 22" 12" 1-1/2" Note: depth including handle is 31-1/2". 35-1/4" to 36-3/4" 28-1/4" 47-7/8" Clearances between range and side wall or combustible material must be at least 12" on each side. 44 monogram.com General features Professional styling. Combining style and quality in OFF BAKE CONV BROIL 48" p rof e s s ion al ran ges 36" dual-fuel professional ranges CLEAN OVEN LIGHT perfect measure, these ranges offer the impressive look and high-performance cooking capabilities of commercial appliances. DOOR LOCKED HEATING Sealed, dual-flame stacked burners. Each gas burner cooking with posts and pans, while the other side is uniquely contoured to allow stir-frying with a wok. 18,000-BTU* grill. The stainless steel grill grate is reversible, with a grooved surface for marinated foods and a rounded side for grilling of delicate foods. A Gourmet Radiant™ tray ensures even heat distribution, while reducing flare-ups from dripping juices. 18,000-BTU* griddle. The 3/8"-thick, stainless steel griddle is sloped to offer a clean cooking surface. Thermostatic control ensures even heating and cooking results. Self-clean oven racks. Heavy-duty, porcelain-coated oven racks are designed to remain in the oven during the oven self-clean cycle for effortless cleaning. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. *15,000 BTU on liquid propane models. 36" professional ZDP36N4DHSS range 36" professional ra n g e s Unique reversible grates. One side offers a flat surface for ZDP36N4DHSS, ZDP36N4RHSS and ZDP36N6HSS (natural gas) ZDP36L4DHSS, ZDP36L4RHSS and ZDP36L6HSS (liquid propane) Overall dimensions (WxHxD in inches): 35-7/8 x 35-1/4– 36 -3/4 x 28-1/4 Amps @240VAC 22.2 208VAC 18.7 KW Rating @240VAC 5.3 208VAC 3.9 Approx. shipping wt. (lbs.) 450 30" professional ranges uses two separate flames to give you a range of precise temperature options, from an ultra low 140°F simmer to a powerful 17,000-BTU* setting. The burners are sealed to the recessed cooktop subsurface for easy cleaning. • Dual-fuel range offers a combination of burners, grill and griddle on cooktop • Natural or LP gas must be specified by model number • Optional 12" or 22" backsplash accessories • All burner grates are reversible to support a round-bottom wok Advance planning for 36" professional ranges All professional ranges offer a number of choices in size and cooktop configurations. • All professional ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. Note: Conversion kits (WB49X10132, Natural to LP and WB49X10133, LP to Natural) are available if the wrong fuel type was ordered. High altitude kit, WB49X10130 (for Natural and LP gas models), is also available. This kit includes orifices for operation at 3,000 to 6,000 feet and another set for operation at 6,000 or more feet. Conversion kits must be installed by a qualified service technician at additional cost. Locate gas and electrical as shown. 4" 4" 12" Gas Supply Electrical requirements Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 30-amp circuit for 36" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range. Gas supply • Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the range regulator. • The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the range regulator. 4" 4" 12" 36" Electric Supply 1-1/2" 45 Advance planning for 36" dual-fuel professional ranges 36" range cooktop configurations Backsplash accessories The 36" professional dual-fuel ranges offer a combination of grill, griddle and burners on top, and a large self-clean, electric convection oven. The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used. ZDP36N4DHSS with 4 burners and griddle (Order ZDP36L4DHSS for LP gas) ZX12B36HSS, 12" backsplash ZX22B36HSS, 22" backsplash with warming shelf Backsplash with warming shelf All Monogram® professional wall mount hoods feature infrared warming lights. The 22"-high backsplash accessory with warming shelf is a perfect complement when installed with the tapered or straight-sided hoods. Restaurant-style professional hoods are shipped with a stainless steel backsplash and warming shelf. ZDP36N4RHSS with 4 burners and grill (Order ZDP36L4RHSS for LP gas) Side view with a backsplash 12" Min. to Combustibles or 0" Min. to Combustibles with 12" or 22" Backsplash 36" Min. to Combustibles ZDP36N6HSS with 6 burners (Order ZDP36L6HSS for LP gas) Backguard 0" Clearance Product dimensions and clearances A 42"- or 36"-wide professional vent hood with a minimum 600 CFM is recommended for installation over this range. Optional h Backsplas 12" 1-1/2" Note: depth including handle is 31-1/2". 35-1/4" to 36-3/4" 28-1/4" The serial plate is located beneath the ledge trim, just above the left knob. 22" 35-7/8" Clearances between range and side wall or combustible material must be at least 12" on each side. 46 monogram.com General features Professional styling. Combining style and quality in OFF BAKE CONV BROIL 48" p rof e s s ion al ran ges 30" dual-fuel professional ranges CLEAN OVEN LIGHT perfect measure, these ranges offer the impressive look and high-performance cooking capabilities of commercial appliances. DOOR LOCKED HEATING Sealed, dual-flame stacked burners. Each gas burner cooking with pots and pans, while the other side is uniquely contoured to allow stir-frying with a wok. Self-clean oven racks. Heavy-duty, porcelain-coated oven racks are designed to remain in the oven during the oven self-clean cycle for effortless cleaning. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. *15,000 BTU on liquid propane models. 30" professional range ZDP30N4HSS 36" professional ra n g e s Unique reversible grates. One side offers a flat surface for ZDP30N4HSS (natural gas) ZDP30L4HSS (liquid propane) Overall dimensions (WxHxD in inches): 29-7/8 x 35-1/4– 36 -3/4 x 26-3/4 Amps @240VAC 18.7 208VAC 16.2 KW Rating @240VAC 4.5 208VAC 3.4 Approx. shipping wt. (lbs.) 420 30" professional ranges uses two separate flames to give you a range of precise temperature options, from an ultralow 140°F simmer to a powerful 17,000-BTU* setting. The burners are sealed to the recessed cooktop subsurface for easy cleaning. • Dual-fuel range offers a gas cooktop and an electric oven • Natural or LP gas must be specified by model number • Optional 9" or 22" backsplash accessories • All burner grates are reversible to support a round-bottom wok Advance planning for 30" professional ranges All professional ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. Note: Conversion kits (WB49X10132, Natural to LP and WB49X10133, LP to Natural) are available if the wrong fuel type was ordered. High altitude kit, WB49X10130 (for Natural and LP gas models), is also available. This kit includes orifices for operation at 3,000 to 6,000 feet and another set for operation at 6,000 or more feet. Conversion kits must be installed by a qualified service technician at additional cost. Locate gas and electrical as shown. 4" 4" 12" 2" Gas Supply 30" 4" 8" Electric Supply 1-1/2" Electrical requirements Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 25-amp circuit for 30" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range. Gas supply • Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the range regulator. • The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the range regulator. 47 Advance planning for 30" dual-fuel professional ranges Product dimensions and clearances Backsplash accessories A 36"- or 30"-wide professional vent hood with a minimum 600 CFM is recommended for installation over this range. The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used. • Install the hood 30" to 36" above the cooking surface. Optional h Backsplas ZX9B30HSS, 9" backsplash ZX22B30HSS, 22" backsplash with warming shelf 22" 9" Backsplash with warming shelf 1-1/2" Note: depth including handle is 29-3/4". 35-1/4" to 36-3/4" 26-3/4" 29-7/8" Clearances between range and side wall or combustible material must be at least 12" on each side. All Monogram® professional wall mount hoods feature infrared warming lights. The 22"-high backsplash accessory with warming shelf is a perfect complement when installed with the tapered or straight-sided hoods. Restaurant-style professional hoods are shipped with a stainless steel backsplash and warming shelf. Side view with a backsplash 12" Min. to Combustibles or 0" Min. to Combustibles with 9" or 22" Backsplash 36" Min. to Combustibles Backguard 0" Clearance The serial plate is located beneath the ledge trim, just above the left knob. 48 monogram.com Prof e s s ion a l g a s cookt ops Gas cooktops 48" professional gas cooktop general features Professional styling. Professional-grade stainless steel with cast-iron grates makes a striking design statement in any kitchen. Unique reversible grates. One side offers a flat surface for cooking with pots and pans, while the other side is uniquely contoured to allow stir-frying with a wok. 18,000-BTU* grill. The stainless steel grate is reversible, with a grooved surface for marinated foods and a rounded side for searing of meats and fish. A Gourmet Radiant™ tray ensures even heat distribution, while reducing flare-ups from dripping juices. 18,000-BTU* griddle. The 3/8" thick, stainless steel griddle is sloped to offer a clean cooking surface. Thermostatic control ensures even heating and cooking results. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. *15,000 BTU on liquid propane models. 48" professional ZGU48N4GHSS gas cooktop ZGU48L4GHSS ZGU48N4GHSS, ZGU48N6RHSS and ZGU48N6DHSS (natural gas) ZGU48L4GHSS, ZGU48L6RHSS and ZGU48L6DHSS (liquid propane) Overall dimensions (WxHxD in inches): 47-7/8 x 8-7/16 x 26-5/8 Amps @120VAC6.6– 4 burner 3.3– 6 burner Approx. shipping wt. (lbs.) 324 Gas cookt op s uses two separate flames to give you a range of precise temperature options, from an ultralow 140°F simmer to a powerful 17,000-BTU* setting. The burners are sealed to the recessed cooktop subsurface for easy cleaning. • Offers three combinations of burners, grill and griddle • Natural or LP gas must be specified by model number • Optional 12" or 22" backsplash accessories • All burner grates are reversible to support a round-bottom wok Induction cookt ops Sealed, dual-flame stacked burners. Each gas burner Advance planning for 48" gas professional cooktops • All professional cooktops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. Electrical requirements Cooktops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time-delay fuse. Note: Conversion kits (WB49X10132, Natural to LP and Gas supply WB49X10133, LP to Natural) are available if the wrong fuel type was ordered. High altitude kit, WB49X10130 (for Natural and LP gas models), is also available. This kit includes orifices for operation at 3,000 to 6,000 feet and another set for operation at 6,000 or more feet. Conversion kits must be installed by a qualified service technician at additional cost. • Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the cooktop regulator. Locate gas inlet on back wall or on floor 2" from back wall 2" Elec tr ic c ookt o ps Professional cooktops offer a number of choices in size and cooktop configurations. • The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the cooktop regulator. 17" 16" 605Dia76 49 Advance planning for 48" professional gas cooktops 48" cooktop surface configurations Installation options The 48" Monogram® professional cooktops are available with a combination of grill, griddle or burners to suit your needs. • The cooktop stainless steel surface will be 1/2" higher than adjacent countertops. ZGU48N4GHSS with 4 burners, grill and griddle (Order ZGU48L4GHSS for LP gas) • In 24"-deep cabinets, the front of the cooktop will be approximately 1-7/8" beyond the front of the countertop. Cooktop Flush With Cabinet Front Front Flush With Cabinets - a Minimum of 25-3/4" Cabinet Depth Required ZGU48N6RHSS with 6 burners and grill (Order ZGU48L6RHSS for LP gas) Cooktop 605Dia81 The serial plate is located beneath the ledge trim, just above the left knob. ZGU48N6DHSS with 6 burners and griddle (Order ZGU48L6DHSS for LP gas) Backsplash accessories Front Projects Outward as Shown From Standard Depth Cabinets 605Dia80 The cooktop requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used. Product dimensions and clearances A 54"- or 48"-wide professional vent hood with a minimum 1200 CFM is recommended for installation over this cooktop. le Availab sh Backspla 47-7/8" Allow Additional Clearance Below the Cooktop Burner Box for the Regulator and Gas Connections Install a matching trim strip to cover the cut edge below the cooktop. 50 Clearances between Backsplash with warming shelf cooktop and side wall All Monogram professional wall mount hoods feature or combustible material infrared warming lights. The 22"-high backsplash accessory must be at least 12" on with warming shelf is a perfect complement when installed each side. 22" 1/2" 12" 26-5/8" with the tapered or straight-sided hoods. Restaurant-style professional hoods are shipped with a stainless steel backsplash and warming shelf. 8-7/16" 22-3/4" 46-1/8" ZX12B48HSS, 12" backsplash ZX22B48HSS, 22" backsplash with warming shelf 7/8" 2-1/2" 8" Clearances between cooktop and side wall or combustible material must be at least 12" on each side. After the cooktop is installed, the bottom front edge of the cutout may need to be covered. Install a trip strip to match cabinetry along the bottom of the cooktop. NOTE: These cooktops require 8" free-space below the burner box. Allow additional clearance below the burner box for the regulator and gas connections. Use a 90° elbow to route the gas connections and limit interference with drawers or other cabinetry features. Side view with a backsplash 12" Min. to Combustibles or 0" Min. to Combustibles with 12" or 22" Backsplash 36" Min. to Combustibles monogram.com Prof e s s ion a l g a s cookt ops Gas cooktops 36" professional gas cooktop general features Professional styling. Professional-grade stainless steel with cast-iron grates makes a striking design statement in any kitchen. Unique reversible grates. One side offers a flat surface for cooking with pots and pans, while the other side is uniquely contoured to allow stir-frying with a wok. 18,000-BTU* grill. The stainless steel grate is reversible, with a grooved surface for marinated foods and a rounded side for searing of meats and fish. A Gourmet Radiant™ tray ensures even heat distribution, while reducing flare-ups from dripping juices. 18,000-BTU* griddle. The 3/8" thick, stainless steel griddle is sloped to offer a clean cooking surface. Thermostatic control ensures even heating and cooking results. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. *15,000 BTU on liquid propane models. 36" professional gas cooktop ZGU36N4DHSS ZGU36L4DHSS ZGU36N4DHSS, ZGU36N4RHSS and ZGU36N6HSS (natural gas) ZGU36L4DHSS, ZGU36L4RHSS and ZGU36L6HSS (liquid propane) Overall dimensions (WxHxD in inches): 35-7/8 x 8-7/16 x 26-5/8 Amps @120VAC3.3– 4 burner 1.0– 6 burner Approx. shipping wt. (lbs.) 228 Gas cookt op s uses two separate flames to give you a range of precise temperature options, from an ultralow 140°F simmer to a powerful 17,000-BTU* setting. The burners are sealed to the recessed cooktop subsurface for easy cleaning. • Offers three combinations of burners, grill and griddle • Natural or LP gas must be specified by model number • Optional 12" or 22" backsplash accessories • All burner grates are reversible to support a round-bottom wok Induction cookt ops Sealed, dual-flame stacked burners. Each gas burner Advance planning for 36" professional gas cooktops • All Professional cooktops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. Note: Conversion kits (WB49X10132, Natural to LP and WB49X10133, LP to Natural) are available if the wrong fuel type was ordered. High altitude kit, WB49X10130 (for Natural and LP gas models), is also available. This kit includes orifices for operation at 3,000 to 6,000 feet and another set for operation at 6,000 or more feet. Conversion kits must be installed by a qualified service technician at additional cost. Locate gas inlet on back wall or on floor 2" from back wall Electrical requirements Cooktops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time-delay fuse. Elec tr ic c ookt o ps Professional cooktops offer a number of choices in size and cooktop configurations. Gas supply • Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the cooktop regulator. • The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the cooktop regulator. 2" 7" 16" 605Dia84 51 Advance planning for 36" professional gas cooktops 36" cooktop surface configurations Installation options The 36" Monogram® professional cooktops are available with a combination of a grill or griddle and 4 burners, or simply 6 burners. • The cooktop stainless steel surface will be 1/2" higher than adjacent countertops. ZGU36N4DHSS with 4 burners and griddle (Order ZGU36L4DHSS for LP gas) • In 24"-deep cabinets, the front of the cooktop will be approximately 1-7/8" beyond the front of the countertop. Cooktop Flush With Cabinet Front Front Flush With Cabinets - a Minimum of 25-3/4" Cabinet Depth Required ZGU36N4RHSS with 4 burners and grill (Order ZGU36L4RHSS for LP gas) Cooktop 605Dia81 Front Projects Outward as Shown From Standard Depth Cabinets ZGU36N6HSS with 6 burners (Order ZGU36L6HSS for LP gas) The serial plate is located beneath the ledge trim, just above the left knob. Backsplash accessories The cooktop requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used. Product dimensions and clearances A 36"- or 42"-wide professional vent hood with a minimum 600 CFM is recommended for installation over this cooktop. Available h Backsplas 35-7/8" Allow Additional Clearance Below the Cooktop Burner Box for the Regulator and Gas Connections 22" 1/2" 12" 26-5/8" 8-7/16" 22-3/4" 35" 605Dia80 ZX12B36HSS, 12" backsplash ZX22B36HSS, 22" backsplash with warming shelf Clearances between cooktop and side wall or combustible materialBacksplash with warming shelf must be at least 12" on All Monogram professional wall mount hoods feature infrared warming lights. The 22"-high backsplash accessory each side. 1/2" 2-1/2" with warming shelf is a perfect complement when installed with the tapered or straight-sided hoods. Restaurant-style professional hoods are shipped with a stainless steel backsplash and warming shelf. Side view with a backsplash Install a matching trim strip to cover the cut edge below the cooktop. 52 8" Clearances between cooktop and side wall or combustible material must be at least 12" on each side. After the cooktop is installed, the bottom front edge of the cutout may need to be covered. Install a trip strip to match cabinetry along the bottom of the cooktop. Note: These cooktops require 8" free-space below the burner box. Allow additional clearance below the burner box for the regulator and gas connections. Use a 90° elbow to route the gas connections and limit interference with drawers or other cabinetry features. 12" Min. to Combustibles or 0" Min. to Combustibles with 12" or 22" Backsplash 36" Min. to Combustibles monogram.com Stainless steel gas cooktop general features Prof e s s ion a l g a s cookt ops Gas cooktops LO SIM HI LITE OFF LO HI LITE OFF LO X-HI LITE OFF LO SIM HI LITE LO LO Silent, precise simmering. The simmer flame delivers a consistent 140°F temperature, without cycling on and off. No simmer plate required. Electronic ignition with auto reignition. Instant ignition system ensures a continuous flame and reignites automatically if accidentally extinguished. Hand-machined, stainless steel knob controls. A red indicator light embedded in each knob makes it easy to view and select heat settings. Knob controls rotate with smooth precision. Interlocking, continuous grates. The continuous-grate design creates a steady surface for cookware, and grates are integrated into the cooktop for a clean, finished appearance. USE WITH LARGER POTS SIM OFF SIM SIM HI HI X-HI LITE LITE LO LO HI HI LITE OFF LITE LITE OFF OFF OFF ZGU384LSMSS ZGU385NSMSS 36" stainless steel ZGU385LSMSS gas cooktop ZGU384NSMSS steel 30" stainless gas cooktop ZGU385NSMSS (natural gas) ZGU385LSMSS (liquid propane) ZGU384NSMSS (natural gas) ZGU384LSMSS (liquid propane) Overall dimensions (WxHxD in inches): 36-3/4 x 3-3/4 x 21-3/16 Amps @120VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 30-3/4 x 3-3/4 x 21-5/8 Amps @120VAC Approx. shipping wt. (lbs.) 5.0 68 •Approved installation over any Monogram single wall oven (except Trivection), or warming drawer •Natural or LP gas must be specified by model number 5.0 55 •Approved installation over any Monogram single wall oven (except Trivection), or warming drawer •Natural or LP gas must be specified by model number Induction cookt ops High-output cooking power. Intense heat ideal for searing and boiling is delivered by an 18,000-BTU* burner, featured on both 36" and 30" cooktops. The 36" model provides a total of 62,000 BTUs,* and the 30" model offers 50,000 BTUs.* LO SIM SIM OFF Dual-flame, stacked burners. Simmer-to-boil flexibility on all burners delivers exceptional performance and convenience. The burners are sealed to the cooktop for easy cleaning. USE WITH LARGER POTS SIM Gas cookt op s Sophisticated design. Angled and hand-finished to perfection, a Monogram stainless steel gas cooktop brings an incomparable mix of edge and elegance to the kitchen. SIM Gas-on-glass cooktop general features Sophisticated styling. The front edge is slightly curved to form an attractive, soft arc that complements other Monogram appliances. LO HI LITE OFF LO HI LO HI LITE range of heat intensities: one 15,000-BTU burner, one 11,000-BTU burner, one 9100-BTU and two 6000-BTU burners. Continuous grate design. Heavy pots are easy to slide from burner to burner. Soft-touch control knobs. Tactile knobs are pleasing to the touch and are dishwasher safe. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. LO LITE OFF HI LO HI LITE OFF LITE OFF 36" gas-on-glass ZGU36KWKWW cooktop Elec tr ic c ookt o ps Precise, versatile temperature control. Five burners provide a OFF ZGU36KSKSS, ZGU36KWKWW and ZGU36KBKBB Overall dimensions (WxHxD in inches): 36 x 3-1/16 x 21-7/16—SS 36 x 3-1/16 x 21-1/4—WW/BB Amps @120VAC 5.0 Approx. shipping wt. (lbs.) 59 • Approved installation over wall oven or warming drawer • LP gas conversion kit included * Natural gas 53 Advance planning for gas cooktops 36" stainless steel gas cooktop 30" stainless steel gas cooktop Stainless steel cooktops are factory set for natural or liquid propane gas. Be sure to order the correct model for your installation. Stainless steel cooktops are factory set for natural or liquid propane gas. Be sure to order the correct model for your installation. Note: If the wrong fuel type is ordered, the cooktop can be Note: If the wrong fuel type is ordered, the cooktop can be converted for other fuel operation. Conversion orifices are packed with each cooktop. They can be installed by a qualified service technician at additional cost. converted for other fuel operation. Conversion orifices are packed with each cooktop. They can be installed by a qualified service technician at additional cost. WB28T10185 High altitude conversion kit is available for operation above 5,000 feet. This kit includes orifices for both LP and natural gas. WB28T10185 High altitude conversion kit is available for operation above 5,000 feet. This kit includes orifices for both LP and natural gas. Electrical requirements Electrical requirements This cooktop requires a 120V, 60Hz power supply. A separate circuit, protected by a 15-amp time-delay fuse or circuit breaker, is required. 20-5/16” at sides This cooktop requires a 120V, 60Hz power supply. A separate circuit, protected by a 15-amp time-delay fuse or circuit breaker, is required. 21”at sides ZGU385NSMSS natural gas ZGU385LSMSS LP gas ZGU384NSMSS natural gas ZGU384LSMSS LP gas 21-3/16” at center 36-3/4” 3-3/4” 3-3/8” Min. from Cutout to Rear Vertical Combustibles 12” Min. from Cutout to Side Walls 19-1/8” 3-3/4” 19-5/8” 2-7/8“ Min. from Cutout to Rear Vertical Combustibles 2-1/2” Min. from Cutout to Front of Countertop 33-7/8” 2-1/2” Min. from Cutout to Front of Countertop 36” Min. Cabinet Base Gas supply Locate gas and electrical supply as shown. The gas inlet is located on the bottom of the burner box, at the center and 2" from the rear. See installation instructions for details. 12” Min. from Cutout to Side Walls 28-1/2” 30” Min. Cabinet Base Gas supply Locate the gas and electrical supply as shown. The gas inlet is located on the bottom of the burner box, 2" from the right side and 1-1/2" from the rear. See installation instructions for details. • The natural gas model is designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide a maximum of 14" water pressure to the cooktop regulator. • The natural gas model is designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide a maximum of 14" water pressure to the cooktop regulator. • The liquid propane model is designed to operate at 11" water column pressure. A regulator is required at the LP source to provide a maximum of 14" water pressure to the cooktop regulator. • The liquid propane model is designed to operate at 11" water column pressure. A regulator is required at the LP source to provide a maximum of 14" water pressure to the cooktop regulator. Combination installations Combination installations Consideration must be given to gas and electrical supply locations when the cooktop is installed with other products in the same cabinet. Always refer to each product’s installation instructions for clearances and electrical requirements. Consideration must be given to gas and electrical supply locations when the cooktop is installed with other products in the same cabinet. Always refer to each product's installation instructions for clearances and electrical requirements. • Install these cooktops with any 36" or wider exhaust hood with 350 CFM or greater air flow rating. • Install these cooktops with any 30" or wider exhaust hood with 350 CFM or greater air flow rating. • This cooktop may be installed above a Monogram single oven. • This cooktop may be installed in combination with a Monogram downdraft vent. See downdraft vents for details. • This cooktop may be installed in combination with a Monogram® 36" downdraft vent or above a Monogram 30" warming drawer. See downdraft vents and warming drawers for details. 54 21-5/8”at center 30-3/4” • This cooktop may be installed above a Monogram warming drawer. See warming drawers for details. • This cooktop may be installed above a Monogram single oven. The serial plate is located on the bottom of the cooktops. monogram.com Gas-on-glass cooktops Gas supply Gas-on-glass cooktops are factory set for natural gas operation. They can be converted to LP operation with a conversion kit shipped with the cooktop. • These cooktops are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide a maximum of 7" water pressure to the cooktop regulator. Electrical requirements • When converted to liquid propane operation, they are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide a maximum of 14" water pressure to the cooktop regulator. 21-1/4" B/W Deep at Center 36" 3-1/16" 2-1/4" Min. to Rear Vertical Combustibles 6" Min. Cutout To Side Walls 19-1/8" 33-7/8" Consideration must be given to gas and electrical supply locations when the cooktop is installed with other products in the same cabinet. Always refer to each product's installation instructions for clearances and electrical requirements. • Install these cooktops with any 36" or wider exhaust hood with 300 CFM or greater air flow rating. • This cooktop may be installed in combination with a Monogram 36" downdraft vent. See downdraft vents for details. 2-1/2" Min. From Front of Countertop • This cooktop may be installed above a Monogram 30" warming drawer. See warming drawers for details. Induction cookt ops ZGU36KSKSS Black with stainless steel trim ZGU36KBKBB Black ZGU36KWKWW White Combination installations Gas cookt op s This cooktop requires a 120V, 60Hz power supply. A separate circuit, protected by a 15-amp time-delay fuse or circuit breaker, is required. The receptacle should be checked by a qualified electrician for correct polarity and proper grounding. 21-7/16" SS Prof e s s ion a l g a s cookt ops Advance planning for gas cooktops • This cooktop may be installed above a Monogram single oven. Locate the gas on the right side, 1" forward of the back of the cutout. Install an electrical outlet 12" below the countertop. 605Dia121 The serial plate is located on the bottom of the cooktops. 605Dia120 Elec tr ic c ookt o ps 1" Min. Forward of Back of Cutout 55 Induction cooktops Induction cooktop general features Induction technology. Induction elements use electricity to produce a magnetic field that reacts with the iron in metal cookware —including cast iron and magnetic stainless steel pans—and transfers the heat to the cookware. Sophisticated styling. Stainless steel-framed models have a reflective metallic finish that captures light and colors inside the kitchen. Black models are smooth from edge to edge, making them easy to clean. Digital controls. Controls are embedded in the cooktop offer added style and convenience. 3,700-watt, 11" element. This element is the most powerful induction element in the industry.* It provides instantaneous heat across 19 different cooking settings. Digital pan-sensing technology. Detects the presence of cookware with magnetic properties, a requirement for induction cooking. Pan size sensor. Automatically adjusts the heating element to the size of the pan. Warm setting. Provides just enough heat to maintain an ideal serving temperature. Timer, control-lock capability and hot-surface indicator. Each setting provides an extra measure of convenience and safety. Flexible installation. Monogram induction cooktops may be installed above a Monogram single wall oven, and is possible due to a shallow-depth configuration of the cooktops and an integrated cooling system. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. *Among leading manufacturers' brands. 56 36" induction cooktop 30" induction cooktop ZHU36RSMSS and ZHU36RBMBB ZHU30RSMSS and ZHU30RBMBB Overall dimensions (WxHxD in inches): 36-1/8 x 4-5/8 x 21—SS 36 x 4-5/8 x 20-7/8 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 29-7/8 x 4-5/8 x 21-1/2—SS 29-3/4 x 4-5/8 x 21-3/8 Amps @240VAC 32.3 208VAC 27.9 Approx. shipping wt. (lbs.) 49 ZHU36RSMSS • Requires a 50-amp circuit • Approved installation over Monogram® wall oven 48.3 41.8 59 ZHU30RSMSS • Requires a 40-amp circuit • Approved installation over Monogram wall oven monogram.com Electrical requirements Combination installations Product rating is 120/208 or 120/240V, 60Hz, 36" cooktops require a 50-amp circuit; and 30" cooktops require a 40-amp circuit. The cooktops must be connected to a supply circuit of the proper voltage and frequency and protected by a timedelay fuse or circuit breaker. Consideration must be given to electrical supply locations when the cooktop is installed with other products in the same cabinet. Always refer to each product’s installation instructions for clearances and electrical requirements. • The 30" cooktop may be installed in combination with a Monogram 30" downdraft vent. Install the 36" cooktop with a 36" downdraft vent. See downdraft vents for details. Junction Box 4-5/8" at Front Baffle 605Dia125 ZHU30RSMSS Stainless Metallic ZHU30RBMBB Black Note: When the cooktop is installed over an oven, the baffle at the front is not required. A The serial plate is located on the bottom of the cooktops. B 2" Min. to Side Walls 1-3/4" Min. 19-5/8" • A Monogram single oven may be installed below these cooktops. Gas cookt op s 3-1/4" All models require 12" minimum clearance below the cooktop bottom to combustible materials. • Install these cooktops with any exhaust hood of the same or greater width; 300 CFM or greater air flow rating is recommended. 2-1/2" Min. to Front Edge Induction cookt ops 16" Min Prof e s s ion a l g a s cookt ops Advance planning for induction cooktops 28-1/2" 30" induction cooktop (in inches) A ZHU30RSMSS ZHU30RBMBB 29-7/8" 20-15/16" 29-3/4" 20-13/16" B (depth at sides) B (at center) 21-1/2" 21-3/8" ZHU36RSMSS Stainless Metallic ZHU36RBMBB Black A B 2" Min. to Side Walls 1-3/4" Min. 19-1/8" Elec tr ic c ookt o ps 605Dia124 2-1/2" Min. to Front Edge 33-7/8" 36" induction cooktop (in inches) A ZHU36RSMSS ZHU36RBMBB 36-1/8" 20-15/32" 36" 20-5/16" B (depth at sides) B (at center) 21" 20-7/8" 605Dia123 57 Electric cooktops Digital electronic cooktop general features Sophisticated styling. Flat plane of smooth ceramic glass provides a near-seamless cooking surface. TIMER Rapid Hi/Lo burner cools down up to three times faster than an electronic standard burner. Rapid reduction in heat helps prevent sauces from boiling over or burning. Dual elements. Radiant heating elements with responsive sensors accommodate small to large pans for enhanced cooking flexibility and performance. Full-function warmer. Positioned at center on 36" models and right rear on 30" models, the convenient warmer offers three warm settings, in addition to the 11 standard heat settings. ZEU36RSFSS and ZEU36RBFBB ZEU30RSFSS and ZEU30RBFBB Overall dimensions (WxHxD in inches): 36-1/8 x 6-1/4 x 21-1/4—SS 36 x 6-1/4 x 21-1/8 Amps @240VAC 35.8 208VAC 31.3 Approx. shipping wt. (lbs.) 56 Overall dimensions (WxHxD in inches): 29-7/8 x 6-1/4 x 21-3/4—SS 29-3/4 x 6-1/4 x 21-5/8 Amps @240VAC 30.8 208VAC 26.9 Approx. shipping wt. (lbs.) 43 • Approved installation over Monogram® wall oven or warming drawer • Approved installation over Monogram wall oven or warming drawer Cooking versatility. Elements vary from 6" to 12" in diameter and can be expanded to suit your cooking needs. Cooking performance. Responsive ribbon elements allow you to simmer and sauté precisely according to recipe. An infinite range of heat settings leaves plenty of room for improvisation. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 36" ribbon electric cooktop ZEU36KSKSS, ZEU36KWKWW and ZEU36KBKBB Overall dimensions (WxHxD in inches): 36-1/8 x 3-1/4 x 21-1/4—SS 36 x 3-1/4 x 21-1/8 Amps @240VAC 40.8 208VAC 35.4 Approx. shipping wt. (lbs.) 45 • Requires a 50-amp circuit 58 ZEU30RWF.EPS 30" ribbon digital electric cooktop stunning look of sleek simplicity, and the surface is completely solid for a dramatic “true black” or “true white” appearance. you to create larger heating zones to match your cooking needs. SENSORS 36" ribbon digital ZEU36RWF.EPS electric cooktop Electric cooktop general features Sophisticated styling. The flush, frameless design offers a Expandable elements. Triple-ring and bridge elements allow TIMER SENSORS monogram.com Electrical requirements Combination installations Product rating is 120/208 or 120/240V, 60Hz. For 240V, connect to a 40-amp circuit; connect to a 30-amp circuit for 208V operation. The cooktops must be connected to a supply circuit of the proper voltage and frequency and protected by a time-delay fuse or circuit breaker. Consideration must be given to electrical supply locations when the cooktop is installed with other products in the same cabinet. Always refer to each product’s installation instructions for clearances and electrical requirements. 6-1/4" Junction Box 5-1/2" All models require 5" minimum clearance below the cooktop bottom to combustible materials. 605Dia126 • Install these cooktops with any exhaust hood of the same or greater width; 300 CFM or greater air flow rating is recommended. • The 30" cooktop may be installed in combination with a Monogram 30" downdraft vent. Install the 36" cooktop with a 36" downdraft vent. See downdraft vents for details. • A 27" warming drawer may be installed beneath a 30" digital cooktop, and a 30" warming drawer may be installed beneath a 36" digital cooktop. Gas cookt op s 3-1/4" 16" Min Prof e s s ion a l g a s cookt ops Advance planning for electric cooktops • A Monogram single oven may be installed below these cooktops. 2" Min. to Side Walls 1-3/4" Min. 19-5/8" The serial plate is located on the bottom of the cooktops. B 2-1/2" Min. to Front Edge Product rating is 120/208 or 120/240V, 60Hz. For 240V, connect to a 50-amp circuit; connect to a 40-amp circuit for 208V operation. The cooktop must be connected to a supply circuit of the proper voltage and frequency and protected by a timedelay fuse or circuit breaker. 28-1/2" 30" digital cooktop (in inches) A ZEU30RSFSS ZEU30RBFBB 29-7/8" 21-5/8" 29-3/4" 21-1/2" B (at center) 605Dia124 ZEU36RSFSS Black with stainless steel trim ZEU36RBFBB Black A ZEU36KSKSS Solid black with stainless steel trim ZEU36KWKWW Solid white ZEU36KBKBB Solid black 36-1/8" SS 36" B/W *3-1/4" 16" Min 33-7/8" A ZEU36RSFSS ZEU36RBFBB 36-1/8" 21-1/4" 36" 21-1/8" B (at center) 605Dia123 2-1/2" Min. to Front Edge Junction Box 36" digital cooktop (in inches) 2" Min. to Side Walls 33-7/8" 19-1/8" 2" Min. to Side Walls 2-1/2" Min. to Front Edge 21-1/4" SS 21-1/8" B/W Deep at Center 1-3/4" Min. B 1-3/4" Min. 19-1/8" Electrical requirements Induction cookt ops A Elec tr ic c ookt o ps 605Dia125 ZEU30RSFSS Black with stainless steel trim ZEU30RBFBB Black 605Dia125 *3-1/4" deep at the front. 4-5/8" deep at the rear conduit location. Requires 5" minimum clearance below the cooktop bottom to combustible materials. 605Dia128 Combination installations Consideration must be given to electrical supply locations when the cooktop is installed with other products in the same cabinet. Always refer to each product’s installation instructions for clearances and electrical requirements. • Install these cooktops with any exhaust hood of the same or greater width; 300 CFM or greater air flow rating is recommended. • The cooktop may be installed with a 36" Monogram downdraft vent. See downdraft vents for details. 59 Pairing hoods with cooking equipment Monogram® hoods are designed to perfectly coordinate with Monogram ranges and cooktops. To learn which cooking products can be combined with the hood you have selected, refer to the charts below. Wall-mounted Island ZV750SY ZV950SDSS ZV800SJ/BJ ZV900SL ZV850SB ZV1050SFSS ZV925SL Downdraft ZVB36SH/WH/BH ZVB30SH/BH All non-pro cooktops All 30" & 36" cooktops and ranges All non-pro cooktops All non-pro cooktops All non-pro cooktops All 30" & 36" cooktops and ranges All non-pro cooktops All non-pro cooktops Chimney Chimney Chimney (slide-out) Chimney Chimney Chimney Chimney Integrated 36" 36" 36" 36" 36" 42" 36" 36"/30" 360 CFM 700 CFM 500 CFM 570 CFM 360 CFM 1080 CFM 570 CFM 500 CFM 8'-10' options No 8'-10' options 8'-10' 5" options 8'-10' options No 8'-10' 1" options No 8', 9' duct cover included; 10' duct cover optional 8', 9' or 10' duct cover included; 10' to 14' duct cover optional 8' to 10' duct cover included; or undercabinet option 8' to 9' 5" duct cover included; 9' 6" to 10' 5" duct cover optional 8', 9' or 10' duct cover required, must order separately 8' duct cover included, 9' or 10' duct cover optional 8' to 9' duct cover included; 9' 1" to 10' 1" Indoor, outdoor duct remote blower cover optional options 6" round 8" round 6" round 8" round 6" round 8" round 8" round 3-1/4" x 10" rect. 100' 100' 100' 100" 100' 100' 100' 150' Installation combinations Style Width Blower rating Recirculating option Vented duct cover options Duct size Equivalent duct length Professional wall-mounted ZV48TSFSS ZV48SSFSS ZV36TSFSS ZV36SSFSS ZV30TSFSS ZV30SSFSS ZV48RSFSS ZV36RSFSS ZV30RSFSS ZV42ISHSS ZV54ISHSS Wall or island hood inserts ZVC48LSS ZVC36LSS Zvc30LSS All Monogram cooktops and ranges All Monogram cooktops and ranges All Monogram cooktops and ranges All 30" & 36" cooktops All Monogram cooktops and ranges All 30", 36" and 48" cooktops and ranges Tapered Straight Restaurant Tapered Tapered Insert 48"/36"/30" 48"/36"/30" 48"/36"/30" 42" 54" 48"/36"/30" 1200/640/640 CFM 1200/640/640 CFM 1200/640/640 CFM 1200 CFM 1200 CFM 1200/640/640 CFM No No No No No No Optional 6" and 12" duct covers –stackable Optional 6" and 12" duct covers, standard or full-width –stackable Optional 6" and 12" duct covers, standard or full-width –stackable 8' duct cover included, 9' to 10' duct cover optional 8' duct cover included, 9' to 10' duct cover optional N/A 10" round 10" round 10" round 10" round 10" round 8" round 150' 150' 150' 150' 150' 100' Professional island Installation combinations Style Width Blower rating Recirculating option Vented duct cover options Duct size Equivalent duct length 60 monogram.com chimney hoods Chimney hoods—wall-mount General features Attractive design. Expertly crafted with uncompromising attention to detail, a Monogram hood adds a striking architectural highlight to your kitchen. Halogen lighting. Six levels of intensity are offered for different needs, from accent to ambient settings. 36" wall-mount glass canopy hood 36" wall-mount ZV950SY.EPS vent hood Removable filters. Filters can be easily detached from the hood for safe cleaning in your dishwasher. ZV900SLSS ZV950SDSS Recirculating kit options for ZV750. An optional vent hood kit for recirculating operation can be installed on the ZV750 hood. ZV800 and ZV900 models are designed to be vented outdoors or to recirculate into the room air. (Air deflector, charcoal filter and a reversible duct cover is packed with models ZV800 and ZV900.) Overall dimensions (WxHxD in inches): 35-7/8 x 3-1/4 x 20-7/16 Amps @ 120VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 35-5/8 x 10 x 25 Amps @ 120VAC Approx. shipping wt. (lbs.) 4.3 123 4.5 110 Custom hood inser ts • Dual blowers • 8" round exhaust duct • 8'-10' ceiling duct cover included • Optional extension duct covers available • Dual blowers • 8" round exhaust duct • 8'-9' 5" ceiling duct cover included • Optional extension duct covers available • Reversible duct cover for vented or recirculating installations. Monogram te l e s c o p i c d o w n d r a f t v e nt s For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. ZV900SJSS professional hoods Powerful ventilation. The variable-speed fan blower provides the power necessary to capture the smoke and fumes produced by high-performance cooking equipment. ZV800SJSS 36" wall-mount vent hood ZV750SY 36" wall-mount hood with retractable glass canopy ZV750SY Overall dimensions (WxHxD in inches): 34-5/8 x 8-1/4 x 21-5/8 Amps @ 120VAC Approx. shipping wt. (lbs.) • 6" round exhaust duct • 8'-9' ceiling duct cover included • Optional extension duct cover available • Optional recirculating kits available ZV800SJSS ZV800BJBB 2.7 81 Overall dimensions (WxHxD in inches): 36 x 1-1/2 x 18-15/16 (with hood extended) Amps @ 120VAC 3.3 Approx. shipping wt. (lbs.) 100 • 6" round exhaust duct • 8'-10' ceiling duct cover included • Reversible duct cover for vented or recirculating installations 61 Advance planning for chimney hoods—wall-mount Wall-mount hoods Ductwork for Z V750SY Chimney vent hoods are available in a 36" width. All models are supplied with a two-piece stainless steel duct cover to conceal the ductwork running from the top of the hood to the ceiling. This vent hood must use 6" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions. • The installation height should be determined in advance. If necessary, accessories for height adjustment should be ordered with the vent hood and be on-site at the time of installation. Decorative duct covers This vent hood is supplied with a two-piece decorative duct cover that will reach an 8-ft. to 9-ft. ceiling. ZX10SY can be ordered to reach 9-ft. to 10-ft. ceiling heights. • Review the following chart to determine the need for an accessory duct cover. Recirculating installation for Z V750 Duct cover accessories for vented installations Ceiling height 8 ft. Up to 9 ft. Up to 10 ft. 10 ft. to 14 ft. ZV750 Included Included ZX10SY — ZV950 Included Included Included ZX14SDSS ZV800 Included Included Included — ZV900 up to 9'5" up to 9'5" ZX90010* — *ZX90010 for 9'6" up to 10'5" Structural suppor t These vent hoods are heavy. Adequate structural support must be provided. Hoods must be secured to vertical studs in the wall or to horizontal supports. • It is strongly recommended that the vent hood and duct cover(s) if used, be on-site before final framing and wall finishing. This will help to accurately locate the ductwork and electrical service. • Final installation will be much easier if the hood is installed before the range or cooktop below. • Mounting templates are provided with the installation instructions to help accurately position the hood above the cooking surface. Electrical requirements These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse. Ductwork planning • Plan the shortest and straightest route for venting exhaust to the outdoors. • Use metal ductwork only • Install a wall cap or roof cap with damper at the exterior opening. Order the wall or roof cap and any transition needed in advance. 62 The ZV750 hood is designed to be vented to the outside, but can easily be converted for recirculating operation. Recirculating kits are available for this hood. These kits include charcoal filters, an air deflector that fits over the exhaust outlet and a vented decorative duct cover. Kits are sized for ceiling height. Recirculating installations Up to 9 ft. ceiling ZXR758C Up to 10 ft. ceiling ZXR7510C 605Dia145 Ductwork for Z V80 0SJSS, Z V80 0BJBB This vent hood must use 6" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions. Decorative duct covers This vent hood is supplied with a two-piece decorative duct cover that will reach an 8-ft. to 10-ft. ceiling. The duct covers are reversible for recirculating operation. Ductwork for Z V9 0 0SL SS This vent hood must use 8" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions. Decorative duct covers This vent hood is supplied with a two-piece decorative duct cover to reach an 8-ft. to 9'5" ceiling. ZX90010 can be ordered to reach 9'6" to 10'5" ceiling heights. All duct covers are reversible for recirculating operation. Ductwork for Z V950SDSS This vent hood must use 8" round duct with a maximum equivalent length of 100 feet for any duct configuration. Decorative duct covers This vent hood is supplied with a two-piece decorative duct cover that will reach an 8-ft. to 10-ft. ceiling. An optional accessory, ZX14SDSS, can be ordered to reach 10-ft. to 14-ft. ceiling heights. For vented operation only. monogram.com Product dimensions and clearances Using duct cover accessories This stainless steel hood can be installed over any Monogram® cooktop except professional models. A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine which accessory may be required for your installation. Model ZV750SY *26-1/4" for 8-ft. ceiling 38-1/4" for 9-ft. ceiling ZV750SY installation heights 34-5/8" 21-5/8" 605Dia148 *25-1/2" Recommended 36" Min. This vent hood must be installed 24" min. to 30" max. above the cooking surface; 25-1/2" is recommended to insure that the duct cover meets the ceiling. The cooking surface should be at least 36" above the floor. 605Dia149 professional hoods 8-1/4" Recirculating accessory ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR758C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C ZXR7510C Custom hood inser ts With accessory ZX10SY duct cover: 38-1/4" to 50-1/4" for 9-ft. to 10-ft. ceiling. Duct cover accessory Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZX10SY ZV750SY duct cover dimensions Model Accessory A B ZV750SY Supplied 18-7/8" 22-13/16" ZV750SY ZX10SY — 34-1/4" ZV750SY ZXR758C 18-7/8" 22-13/16" ZV750SY ZXR7510C 18-7/8" 34-5/8" te l e s c o p i c d o w n d r a f t v e nt s *Height to Ceiling Actual Possible hood ceiling installation height height* 7' 11" 24-1/2" 8' 0" 25-1/2" 8' 1" 25-1/2" to 26-1/2" 8' 2" 25-1/2" to 27-1/2" 8' 3" 25-1/2" to 28-1/2" 8' 4" 25-1/2" to 29-1/2" 8' 5" 25-1/2" to 30" 8' 6" 25-1/2" to 30" 8' 7" 25-1/2" to 30" 8' 8" 25-1/2" to 30" 8' 9" 25-1/2" to 30" 8' 10" 25-1/2" to 30" 8' 11" 25-1/2" to 30" 9' 0" 25-1/2" to 30" 9' 1" 25-1/2" to 30" 9' 2" 25-1/2" to 30" 9' 3" 25-1/2" to 30" 9' 4" 25-1/2" to 30" 9' 5" 25-1/2" to 30" 9' 6" 25-1/2" to 30" 9' 7" 25-1/2" to 30" 9' 8" 25-1/2" to 30" 9' 9" 25-1/2" to 30" 9' 10" 25-1/2" to 30" 9' 11" 25-1/2" to 30" 10' 0" 25-1/2" to 30" *Based on 36" countertop height. chimney hoods Advance planning for chimney hoods—wall-mount The serial plate is located behind the removable filters. 63 Advance planning for chimney hoods—wall-mount Product dimensions and clearances Using duct cover accessories This stainless steel hood can be installed over any Monogram® cooktop including a professional 36" cooktop and a 36" or 30" professional range. A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine installation height and the need for a duct cover accessory. This vent hood must be installed 24" min. to 30" max. above the cooking surface. The hood installation height, from the cooktop surface to the bottom of the hood, depends upon ceiling height. Model ZV950SDSS *24-1/2" for 8-ft. ceiling 36-1/2" for 9-ft. ceiling 36" to 44" for 9-ft. to 10-ft. ceiling. (for ceilings between 9'6" and 10 ft. mount the hood 30" above the cooking surface). *Height to Ceiling 10" 25" 35-5/8" Note: The supplied two-piece duct cover is adjustable to fit 8-ft. to 10-ft. ceilings. For ceiling heights greater than 10 ft. and up to 14 ft., order ZX14SDSS stainless steel duct cover accessory. 605Dia146 The distance between the cooking surface and the bottom of the hood should be: 25-1/2" max. for 8-ft. ceiling height. 25-1/2" to 30" for 9-ft. ceiling height. 30" min. for 10-ft. ceiling height. ZV950SDSS installation heights Actual Possible hood ceiling installation height height* 7' 11" 24-1/2" 8' 0" 25-1/2" 8' 1" 25-1/2" to 26-1/2" 8' 2" 25-1/2" to 27-1/2" 8' 3" 25-1/2" to 28-1/2" 8' 4" 25-1/2" to 29-1/2" 8' 5" 25-1/2" to 30" 8' 6" 25-1/2" to 30" 8' 7" 25-1/2" to 30" 8' 8" 25-1/2" to 30" 8' 9" 25-1/2" to 30" 8' 10" 25-1/2" to 30" 8' 11" 25-1/2" to 30" 9' 0" 25-1/2" to 30" 9' 1" 26-1/2" to 30" 9' 2" 26-1/2" to 30" 9' 3" 26-1/2" to 30" 9' 4" 26-1/2" to 30" 9' 5" 26-1/2" to 30" 9' 6" 30" 9' 7" 30" 9' 8" 30" 9' 9" 30" 9' 10" 30" 9' 11" 30" 10' 0" - 14" 0" 30" *Based on 36" countertop height. ZV950DSS duct cover dimensions Duct cover accessory Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied ZX14SDSS ZX14DSS duct cover dimensions Installation Height Depending on Ceiling Height 36" Min. Plan the installation height carefully to avoid unsightly gaps above the hood. 605Dia147 Note: Install the hood 30" min. above the cooking surface over a professional range or cooktop. Installation over a professional range or cooktop The ZV950 hood must be installed 30" minimum above the cooking surface of a professional range or cooktop. The ceiling height must be at least 8' 5" for this installation combination. 64 The serial plate is located behind the removable filters. monogram.com Product dimensions and clearances Determine installation height This vent hood can be installed for vented or recirculating operation. It can be installed over any Monogram cooktop (except Professional models). Use this chart to accurately determine installation heights, depending on your ceiling heights. chimney hoods Advance planning for chimney hoods—wall-mount Wall-mount ZV800 installation heights Venting and recirculating wall-mount installations The vent hood must be installed 24" min. to 30" max. above the standard 36" countertop. The hood installation height, from the cooking surface to the bottom of the hood, depends on the ceiling height. Vented or recirculating installations in a cabinet Possible recirculating installation 24" to 25" 24" to 26" 24" to 27" 24" to 28" 24" to 29" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 24" to 30" 25" to 30" 26" to 30" professional hoods The canopy extends forward 5-7/8". Actual ceiling Possible vented height installation height* 7' 11" 24" to 27" 8' 0" 24" to 28" 8' 1" 24" to 30" 8' 2" 24" to 30" 8' 3" 24" to 30" 8' 4" 24" to 30" 8' 5" 24" to 30" 8' 6" 24" to 30" 8' 7" 24" to 30" 8' 8" 24" to 30" 8' 9" 24" to 30" 8' 10" 24" to 30" 8' 11" 24" to 30" 9' 0" 24" to 30" 9' 1" 24" to 30" 9' 2" 24" to 30" 9' 3" 24" to 30" 9' 4" 24" to 30" 9' 5" 24" to 30" 9' 6" 24" to 30" 9' 7" 25" to 30" 9' 8" 26" to 30" 9' 9" 27" to 30" 9' 10" 28" to 30" 9' 11" 29" to 30" 10' 0" 30" *Based on 36" countertop height. Custom hood inser ts ZV800SJSS, Stainless steel ZV800BJBB, Black Telescoping duct covers are provided to reach 8 ft. to 10 ft. ceiling heights. The vent hood height must be at least 24" min. above the standard 36" countertop. • In both vented and recirculating installations, the cabinet must measure at least 20" from the bottom frame to the inside top. Louver at top of cabinet in this example te l e s c o p i c d o w n d r a f t v e nt s • The cabinet must be at least 12" deep. The hood housing will occupy the interior cabinet space. ZV800SJSS and JV800BJBB duct cover dimensions The serial plate is located behind the removable filters. Recirculating installation • The exhaust must be returned to the kitchen; it cannot exit inside the cabinet. • The exhaust can be directed through the soffit or upper cabinet to a vent opening with a minimum of 28 square inches or 6" round. A customer-supplied decorative louver should be installed. • The exhaust should be directed away from other cabinet surfaces, either exposed or hidden. 65 Advance planning for chimney hoods—wall-mount Product dimensions and clearances Determine installation height This glass canopy hood can be installed over any Monogram® cooktop (except Professional models). Use this chart to accurately determine installation heights, depending on your ceiling heights. Model ZV900SLSS *The supplied duct cover is sized to fit 8' to 9'5" ceiling heights. For 9' 6" to 10' 5" ceilings, order ZX90010 *Height to Ceiling 20 7/16" 3 1/4" 35 7/8" NOTE: Measure installation height from the cooking surface to the outer glass portion of the hood. 24" Min. 30" Max. 36" Min. • The vent hood must be installed 24" min., and 30" max. above the cooking surface. The hood installation height above the cooking surface depends upon the ceiling height. • The cooking surface should be at least 36" above the floor. • This hood can be installed for recirculating operation. No kits required. ZV900SLSS duct cover dimensions NOTE: ZX90010 accessory consists of one 40" long duct cover. The serial plate is located behind the removable filters. 66 Wall-mount ZV900 installation heights Actual Possible vented Possible ceiling installation recirculating height height* installation* 7' 11" 24" to 26" 24" to 25" 8' 0" 24" to 27" 24" to 26" 8' 1" 24" to 28" 24" to 27" 8' 2" 24" to 29" 24" to 28" 8' 3" 24" to 30" 24" to 29" 8' 4" 24" to 30" 24" to 30" 8' 5" 24" to 30" 24" to 30" 8' 6" 24" to 30" 24" to 30" 8' 7" 24" to 30" 24" to 30" 8' 8" 24" to 30" 24" to 30" 8' 9" 24" to 30" 24" to 30" 8' 10" 24" to 30" 24" to 30" 8' 11" 24" to 30" 24" to 30" 9' 0" 24" to 30" 24" to 30" 9' 1" 26" to 30" 24" to 30" 9' 2" 27" to 30" 24" to 30" 9' 3" 28" to 30" 24" to 30" 9' 4" 29" to 30" 24" to 30" 9' 5" 30" 24" to 30" 9' 6" 24" to 30" 24" to 30" 9' 7" 24" to 30" 24" to 30" 9' 8" 24" to 30" 24" to 30" 9' 9" 24" to 30" 24" to 30" 9' 10" 24" to 30" 24" to 30" 9' 11" 24" to 30" 24" to 30" 10' 0" 24" to 30" 24" to 30" 10' 1" 24" to 30" 24" to 30" 10' 2" 25" to 30" 24" to 30" 10' 3" 26" to 30" 25" to 30" 10' 4" 27" to 30" 26" to 30" 10' 5" 28" to 30" 27" to 30" *Based on 36" countertop height. Duct cover accessory Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 ZX90010 monogram.com chimney hoods Chimney hoods—islands General features Attractive design. Expertly crafted with uncompromising attention to detail, a Monogram hood adds a striking architectural highlight to your kitchen. Powerful ventilation. The variable-speed fan blower provides the power necessary to capture the smoke and fumes produced by high-performance cooking equipment. Monogram Halogen lighting. Six levels of intensity are offered for different needs, from accent to ambient settings. 36" island vent hood Removable filters. Filters can be easily detached from the hood for safe cleaning in your dishwasher. ZV850SB professional hoods ZV925SLSS Overall dimensions (WxHxD in inches): 35-3/8 x 8-1/4 x 27-1/2 Amps @ 120VAC Approx. shipping wt. (lbs.) 2.7 81 • 6" round exhaust duct • Required duct covers must be ordered separately • Optional recirculating kits available Overall dimensions (WxHxD in inches): 35-7/8 x 3-3/4 x 27-9/16 Amps @ 120VAC Approx. shipping wt. (lbs.) 4.6 146 • 8" round exhaust duct • 8'–9' duct cover included • Optional extension duct covers available • Reversible duct cover for vented or recirculating installation Custom hood inser ts For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. ZV850SB 42" island vent hood ZV1050SFSS te l e s c o p i c d o w n d r a f t v e nt s Recirculating options. An optional vent hood kit for recirculating operation can be installed on the ZV850. Model ZV925 is designed to be vented outdoors or to recirculate into the room air. ZV900SJSS 36" island glass canopy vent hood ZV1050SFSS Overall dimensions (WxHxD in inches): 42 x 10 x 31-1/2 Amps @ 120VAC Approx. shipping wt. (lbs.) 6.7 150 • Dual blowers • 8" round exhaust duct • 8' ceiling duct cover included • Optional extension duct covers available 67 Advance planning for chimney hoods—island Stainless steel island hoods Ductwork for Z V850SB Chimney vent hoods are available in 42" and 36" widths. This vent hood must use 6" round duct. • Duct cover accessories to meet ceiling heights are required for the ZV850 island hood. One accessory must be ordered with the vent hood. • Plan the shortest and straightest route for venting exhaust to the outdoors. • The ZV925 vent hood is supplied with a two-piece decorative duct cover to reach an 8-ft. to 9-ft. ceiling. An optional duct cover accessory is available for 9'1" to 10'1" ceiling heights. • For satisfactory performance, duct run should not exceed 100 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions. • The ZV1050 hood is supplied with a duct cover for an 8-ft. ceiling height (7' 11" to 8' 1"). Optional duct cover accessories are available for 9-ft. and 10-ft. ceiling heights. • Install a wall cap or roof cap with damper at the exterior opening. Order the wall or roof cap and any transition needed in advance. • The installation height must be determined in advance for both models. • All duct cover accessories must be ordered with the vent hood and be on-site at the time of installation. • Review the following chart to determine the appropriate accessory duct cover. Required duct cover accessories for vented installations Ceiling height 8 ft. Up to 9 ft. Up to 10 ft. ZV850 ZX858SB ZX859SB ZX8510SB ZV925 Supplied Supplied ZX92510 ZV1050 Supplied ZX1059SFSS ZX10510SFSS Structural suppor t These vent hoods are heavy. Adequate structural support must be provided. Hoods must be secured to cross framing positioned between ceiling joists. • The vent hood and duct cover(s) must be on-site before final framing and wall finishing. This will help to accurately locate the ductwork and electrical service. • Final installation will be much easier if the hood is installed before the range or cooktop below. • Mounting templates are provided with the installation instructions to help accurately position the hood on the ceiling above the cooking surface. • Use metal ductwork only. Ductwork for Z V925SL SS This vent hood must use 8" round duct. • Plan the shortest and straightest route for venting exhaust to the outdoors. • Use metal ductwork only. • For satisfactory performance, duct run should not exceed 100 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions. Ductwork for Z V1050SFSS This vent hood must use 8" round duct. • Plan the shortest and straightest route for venting exhaust to the outdoors. • Use metal ductwork only. • For satisfactory performance, duct run should not exceed 100 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions. • Install a wall cap or roof cap with damper at the exterior opening. Order the wall or roof cap and any transition needed in advance. Recirculating installation Electrical requirements These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse. • The junction box is located on top of the hood. Route the wiring as close to the installation as possible through the ceiling. Refer to the installation instructions for details. The ZV850 hood is designed to be vented to the outside, but it can easily be converted for recirculating operation. Recirculating kits are available for the ZV850 hood. These kits include charcoal filters, a support frame with air deflector and a vented decorative duct cover to complete the installation. Kits are sized for ceiling height. Recirculating installations 8 ft. ZXR858C 9 ft. ZXR859C 10 ft. ZXR8510C The ZV925SLSS is designed for either vented or recirculating operation. All necessary parts are included. 605Dia152 The ZV1050 is not convertible to recirculating operation. 68 monogram.com Product dimensions and clearances Using duct cover accessories This stainless steel hood can be installed over any Monogram® cooktop except Professional models. Accessories to meet correct ceiling heights are required. A duct cover accessory is required for all ceiling heights. Use this chart to determine the correct duct cover accessory for 8-ft. to 10-ft. ceilings that must be ordered with the hood. Model ZV850SB *26-1/4" for 8-ft. ceiling using ZX858SB accessory ZV850SB installation heights 35-3/8" 27-1/2" 605Dia150 *25-1/2" Recommended 36" Min. This vent hood must be installed 24" min. to 30" max. above the cooking surface; 25-1/2" is recommended to ensure that the duct cover meets the ceiling. The cooking surface should be at least 36" above the floor. 605Dia151 Recirculating accessory ZXR858C ZXR858C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR859C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C ZXR8510C professional hoods 8-1/4" Duct cover accessory ZX858SB ZX858SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX859SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB ZX8510SB Custom hood inser ts 38-1/4" for 9-ft. ceiling using ZX859SB accessory 50-1/8" for 10-ft. ceiling using ZX8510SB accessory Actual Possible hood ceiling installation height height* 7' 11" 24-1/2" 8' 0" 25-1/2" 8' 1" 25-1/2" to 26-1/2" 8' 2" 25-1/2" to 27-1/2" 8' 3" 25-1/2" to 28-1/2" 8' 4" 25-1/2" to 29-1/2" 8' 5" 30" 8' 6" 30" 8' 7" 30" 8' 8" 30" 8' 9" 30" 8' 10" 30" 8' 11" 30" 9' 0" 30" 9' 1" 30" 9' 2" 30" 9' 3" 30" 9' 4" 30" 9' 5" 30" 9' 6" 30" 9' 7" 30" 9' 8" 30" 9' 9" 30" 9' 10" 30" 9' 11" 30" 10' 0" 30" *Based on 36" countertop height. ZV850 duct cover dimensions Vented installation A ZV858SB 14-3/16" ZX859SB 20-1/2" ZX8510SB 26" B 15-3/16" 22-1/2" 27-1/2" Recirculating installation A ZV858C 14-3/16" ZX859C 21-7/8" ZX8510C 26" B 15" 22-1/2" 27-15/16" te l e s c o p i c d o w n d r a f t v e nt s *Height to Ceiling chimney hoods Advance planning for chimney hoods—island 9-7/16" B A 15-3/4" The serial plate is located behind the removable filters. 69 Advance planning for chimney hoods—island Product dimensions and clearances Determine installation height This glass canopy hood can be installed over any Monogram® cooktop (except Professional models). Use this chart to accurately determine installation heights, depending on your ceiling heights. Model ZV925SLSS *The supplied duct *Height cover is sized to to fit 8' to 9' ceiling Ceiling heights. For 9'1" to 10'1" ceilings, order ZX92510. 27 9/ 16" 3 1/4" 35 7/8" NOTE: Measure installation height from the cooking surface to the outer glass portion of the hood. 24" Min. 30" Max. 36" Min. • This hood must be installed 24" min. and 30" max. above the cooking surface. The cooking surface should be at least 36" above the floor. Important • The hood installation height depends on the ceiling height. Use the chart shown to determine the EXACT installation height. • Duct cover side trim pieces are provided and must be used to cover installation screws. They are sized to fit the specific installation heights shown in the chart. • This hood can be installed for recirculating operation. No kits required. ZV925SLSS duct cover dimensions 14” Side Trim Side Trim 23-1/4” NOTE: ZX92510 accessory consists of one 36-3/4" long duct cover. 24-3/4” 12-3/16” The serial plate is located behind the removable filters. 70 ZV925 installation heights Hood Possible installation ceiling height height* 7' 11" 25" 8' 0" 27" 8' 1" 24" 8' 1" 28" 8' 2" 25" 8' 2" 29" 8' 3" 26" 8' 3" 30" 8' 4" 27" 8' 5" 24" 8' 5" 28" 8' 6" 25" 8' 6" 29" 8' 7" 26" 8' 7" 30" 8' 8" 27" 8' 9" 24" 8' 9" 28" 8' 10" 25" 8' 10" 29" 8' 11" 26" 8' 11" 30" 9' 0" 27" ZV92510 accessory duct cover 9' 1" 24" 9' 1" 28" 9' 2" 25" 9' 2" 29" 9' 3" 26" 9' 3" 30" 9' 4" 27" 9' 5" 24" 9' 5" 28" 9' 6" 25" 9' 6" 29" 9' 7" 26" 9' 7" 30" 9' 8" 27" 9' 9" 24" 9' 9" 28" 9' 10" 25" 9' 10" 29" 9' 11" 26" 9' 11" 30" 10' 0" 27" 10' 1" 28" *Based on 36" countertop height. Mounting frame height 30-1/2" 30-1/2" 34-1/2" 30-1/2" 34-1/2" 30-1/2" 34-1/2" 30-1/2" 34-1/2" 38-1/2" 34-1/2" 38-1/2" 34-1/2" 38-1/2" 34-1/2" 38-1/2" 42-1/2" 38-1/2" 42-1/2" 38-1/2" 42-1/2" 38-1/2" 42-1/2" Duct cover accessory Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied Supplied 46-1/2" 42-1/2" 46-1/2" 42-1/2" 46-1/2" 42-1/2" 46-1/2" 50-1/2" 46-1/2" 50-1/2" 46-1/2" 50-1/2" 46-1/2" 50-1/2" 54-1/2" 50-1/2" 54-1/2" 50-1/2" 54-1/2" 50-1/2" 54-1/2" 54-1/2" ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 ZX92510 monogram.com Product dimensions and clearances Using duct cover accessories This stainless steel hood can be installed over any Monogram cooktop or range, including professional models. A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine the need for a duct cover accessory. Model ZV1050SFSS *20" for 8-ft. ceiling using supplied duct cover ZV1050SFSS installation heights *Height to Ceiling 32" for 9-ft. ceiling using ZX1059SFSS accessory 44" for 10-ft. ceiling using ZX10510SFSS accessory 10" This vent hood is supplied with a decorative duct cover to reach 8-ft. ceiling height, or between 7' 11" and 8' 1". 605Dia153 *30" Recommended 36" Min. professional hoods 42" Duct cover accessory Supplied Supplied Supplied ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX1059SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS ZX10510SFSS Custom hood inser ts 31-1/2" Actual Possible hood ceiling installation height height* 7' 11" 29" 8' 0" 30" 8' 1" 30" 8' 2" 25-1/2" to 30" 8' 3" 25-1/2" to 30" 8' 4" 25-1/2" to 30" 8' 5" 25-1/2" to 30" 8' 6" 25-1/2" to 30" 8' 7" 25-1/2" to 30" 8' 8" 25-1/2" to 30" 8' 9" 25-1/2" to 30" 8' 10" 25-1/2" to 30" 8' 11" 25-1/2" to 30" 9' 0" 25-1/2" to 30" 9' 1" 25-1/2" to 30" 9' 2" 25-1/2" to 30" 9' 3" 25-1/2" to 30" 9' 4" 25-1/2" to 30" 9' 5" 25-1/2" to 30" 9' 6" 25-1/2" to 30" 9' 7" 25-1/2" to 30" 9' 8" 25-1/2" to 30" 9' 9" 25-1/2" to 30" 9' 10" 25-1/2" to 30" 9' 11" 25-1/2" to 30" 10' 0" 25-1/2" to 30" *Based on 36" countertop height. chimney hoods Advance planning for chimney hoods—island *9-ft. to 10-ft. ceilings may be 25-1/2" to 30" clearance. The distance between the cooking surface and the bottom of the hood must be at least 25-1/2". The 30" recommended installation height above the standard 36" countertop will ensure duct cover fit to the ceiling. For 9-ft. and 10-ft. ceiling heights, the hood may be lowered to 25-1/2" over the cooking surface. ZV1050 duct cover dimensions Model Accessory A B ZV1050 Supplied 11-1/2" 12" ZV1050 ZX1059 19" 20" ZV1050 ZX10510 25" 26" te l e s c o p i c d o w n d r a f t v e nt s 605Dia172 This vent hood must be installed 25 1/2" min. and 30" max. above the cooking surface. The serial plate is located behind the removable filters. • When installing this island hood above a Monogram professional range or cooktop, installation clearance must be at least 30". Important: Clearances may vary due to type of cooking product and local codes. Check with local inspectors to be sure the standard is applicable. 71 Professional hoods 4 8", 36" and 30" tapered-sided hoods ZV48TSFSS 48", 36" and 30" straight-sided hoods ZV48SSFSS 54" and 42" island hoods ZV48RSFSS, ZV36RSFSS and ZV30RSFSS ZV48TSFSS, ZV36TSFSS and ZV30TSFSS ZV48SSFSS, ZV36SSFSS and ZV30SSFSS ZV54ISHSS and ZV42ISHSS Overall dimensions (WxHxD in inches): 48 x 22-1/2 x 25 36 x 22-1/2 x 25 30 x 22-1/2 x 25 Amps @ 110 Volts 12.4/6.4/6.4 Approx. shipping wt. (lbs.) 130/110/100 Overall dimensions (WxHxD in inches): 48 x 18 x 25 36 x 18 x 25 30 x 18 x 25 Amps @ 110 Volts 12.4/6.4/6.4 Approx. shipping wt. (lbs.) 130/110/100 Overall dimensions (WxHxD in inches): 48 x 18 x 25 36 x 18 x 25 30 x 18 x 25 Amps @ 110 Volts 12.4/6.4/6.4 Approx. shipping wt. (lbs.) 130/110/100 Overall dimensions (WxHxD in inches): 54 x 24 x 36-1/4 42 x 20 x 31-1/2 • 10" round exhaust duct • Exhaust damper • Snap-in blower assembly • 6" and 12" standard or full-width stackable duct covers (order separately) • Stainless steel backsplash included • Warming shelf included • 10" round exhaust duct • Exhaust damper • Snap-in blower assembly • 6" and 12" standard-width stackable duct covers (order separately) • 10" round exhaust duct • Exhaust damper • Snap-in blower assembly • 6" and 12" standard or full-width stackable duct covers (order separately) • 10" round exhaust duct • 8' ceiling duct cover and support (included) • Optional 9'-10' ceiling duct cover and support available 4 8", 36" and 30" restaurant-style hoods ZV48RSFSS General features Professional styling. Crafted of premium-grade stainless steel, with every edge buffed by hand, Monogram professional hoods make a compelling statement of quality and refinement. Powerful ventilation. A powerful centrifugal blower, up to 1200 CFM, and variable-speed control keep your kitchen free of fumes and excess heat. Infrared warming lamps. Powerful infrared lamps on wall-mounted hoods cast a warm glow over the cooking surface, while generating the heat necessary to keep baked goods at ready-to-serve temperatures. Brilliant task lighting. Halogen lights illuminate the cooktop surface below and can be adjusted to complement the dining occasion. Removable filters. During ventilation, stainless steel filters trap airborne grease particles, and can be easily removed for safe cleaning in your dishwasher. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 72 Amps @ 120 Volts Approx. shipping wt. (lbs.) 10.4/9.5 210/170 monogram.com Professional vent hoods Ductwork planning Restaurant-style, tapered- and straight-sided hoods Select a professional hood with straight or tapered sides, or a dramatic restaurant-style hood to match the width of the range or cooktop. All professional hoods are available in 48", 36" and 30" widths. Restaurant-style, tapered- and straight-sided hoods These vent hoods are equipped for 10" round ductwork. For best performance, use 10" round ductwork on the 48"-wide hoods. 36" and 30" hoods may be transitioned to 8" round. • Optional accessories must be ordered with the hood and be on-site before final framing and wall finishing. • A mounting template is provided with each hood to help accurately locate the hood above the cooking surface and to locate the mounting frame and screws. • For a finished appearance, a top cover is supplied with both hoods. Install the top cover whenever the top of the hood will be visible. Structural suppor t Restaurant-style, tapered- and straight-sided hoods All professional hoods weigh over 100 pounds; therefore adequate structural support must be provided. Hoods must be secured to vertical studs or to studs in the soffit. • It is strongly recommended that the vent hood and duct cover(s) if used, be on-site before final framing and wall finishing. This will help to accurately locate the ductwork and electrical service. • Final installation will be much easier if the hood is installed before the range or cooktop underneath. Professional hoods • Accessories are available to reach ceiling heights from 8' 6" to 10' 4". These accessories include telescoping support frames and decorative covers. • Plan the shortest and straightest route for venting exhaust to the outdoors. • Use metal ductwork only. • For satisfactory performance, duct run should not exceed 150 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions. • Install a wall cap or roof cap with damper at the exterior opening. Order the wall or roof cap and any transition needed in advance. Island hoods These vent hoods are equipped for 10" round rigid metal duct. Maximum equivalent duct length is 150 ft. Install a roof cap with damper at the exterior opening. Custom hood inser ts Island hoods Both models are shipped with a support frame and duct cover for ceiling heights of 7' 11" up to 8' 5". • Hoods may be vented vertically through upper cabinets, soffit or ceiling. The blower outlet is 8-1/8" x 8". A duct transition to 10" round with damper is supplied for vertical exhaust. Use locally supplied elbows to vent horizontally. Electrical requirements These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse. • On wall-mounted hoods, the back side is recessed, providing a large area for the house wiring to exit the wall and be routed to the rear knockout and junction box. • T he exact location for the house wiring depends on the installation height and size of the hood. See installation instructions for details. te l e s c o p i c d o w n d r a f t v e nt s • All models can be installed onto a wall or beneath a soffit. Decorative duct covers are available for all models. The duct cover conceals the ductwork running from the top of the hood to the ceiling or soffit. Duct covers are available in 6" or 12" heights. Stack one or more duct covers to reach your ceiling height. chimney hoods Advance planning for professional hoods • On wall-mounted hoods, the junction box is fastened to the back of the hood on the right side. If necessary, the junction box can be relocated to the top of the hood. • On island hoods, the junction box is located on the top of the hood and is concealed by ductwork. Island hoods These vent hoods are heavy. Adequate structural support must be provided. The ceiling structure must be capable of supporting the weight of the hoods and any inadvertent user contact loads (approximately 300 lbs.). 73 Advance planning for professional hoods Restaurant-style hood dimensions Straight-sided hood dimensions 12" 12" 47-15/16" 10" ZV48RSFSS 12" ZV48SSFSS 18" 22-1/2" 12" 35-15/16" 605Dia138 10" ZV36RSFSS 18" 22-1/2" 25" 12" 10" 29-15/16" 29-15/16" 25" Tapered-sided hood dimensions Island hood dimensions 605Dia136 16" 40" 33" ZV48TSFSS 18" 25" 12" 24" 47-15/16" 28" 717Dia5 ZV30SSFSS 18" 29-15/16" 12" ZV36SSFSS 35-15/16" 605Dia133 ZV30RSFSS 22-1/2" 605Dia140 605Dia132 12" 29-15/16" 25" 35-15/16" 25" 35-15/16" 605Dia139 47-15/16" 25" 47-15/16" 25" 47-15/16" 36-1/4" ZV36TSFSS Model ZV54ISHSS supplied duct cover dimensions: 20-1/4"W x 12"D x 5"H 54" 18" 25" 12" 14" 35-15/16" 22" 717Dia6 25-3/4" Model ZV42ISHSS supplied duct cover dimensions: 16"W x 12"D x 9"H ZV30TSFSS 20" 18" 25" 74 29-15/16" 31-3/4" 42" monogram.com Advance planning for professional hoods Restaurant-style hoods Determine bottom of hood location by subtracting 12-1/2" from the desired installation height. Island hoods These vent hoods must be installed 30" min. and 36" max. above the cooking surface—regardless of ceiling height. Therefore, installation height of the hood depends on the exact ceiling height of the kitchen. 8 ft. Ceiling Note: Exact installation height is affected by the use of the supplied warming shelf and by the use of duct covers. chimney hoods Installation height requirements 8 ft. Ceiling 9" Supplied Duct Cover 5" Supplied Duct Cover Dim. A Restaurant-style hoods are supplied with a stainless steel backsplash and a warming shelf. Install the hood with or without either. Clearances to the cooking surface will vary depending upon use of the warming shelf. 605Dia141 31" 31" ZV42I ZV54I Professional hoods Installation Height Example: Hood installation height with 8 ft. ceilings. • If the ceiling height is 7' 11", the hood installation height above the cooking surface will be 30". • If the ceiling height is 8' 5", the hood installation height above the cooking surface will be 36". 32" Min. 38" Max. Installation without warming shelf Install these vent hoods 30" min. to 36" max. above the cooking surface of any Professional-style range or cooktop. Installation with supplied warming shelf Install the hood 32" min. to 38" max. above any type cooking surface when the warming shelf is used. 605Dia137 12" Duct Cover 6" Duct Cover Hood 6" duct cover 12" duct cover ZV48 ZX48DC6 ZX48DC12 ZV36, ZV30 ZX36DC6 ZX36DC12 If you are installing the hood above a gas or electric drop-in style cooktop, the hoods may be installed as low as 24" above the cooking surface. Tapered- and straight-sided hoods Install these vent hoods 30" min. to 36" max. above the cooking surface of any professional range or cooktop. If you intend to install the hood above a gas or electric drop-in style cooktop, the hoods may be installed as low as 24" above the cooking surface. Note: Exact installation height may be determined by use of one or more duct covers. Standard duct covers Standard duct covers are for professional restaurant-style, tapered- and straight-sided hoods. Available in 6" and 12" heights, duct covers may be stacked in various combinations to conceal the ductwork running from the top of the hood. To avoid unsightly gaps above the hood, plan the hood installation height with consideration to duct cover use. te l e s c o p i c d o w n d r a f t v e nt s 30" Min. 36" Max. Custom hood inser ts Duct cover accessories Dimensions (in inches) 6H or 12H x 19-11/16W x 11-7/8D 6H or 12H x 15-3/4W x 11-7/8D 605Dia142 Full-width duct covers Full-width duct covers are for professional restaurant-style and straight-sided hoods only. Available in 6" and 12" heights, duct covers span the full width of the hood and may be stacked in various combinations. To avoid unsightly gaps above the hood, plan the hood installation height with consideration to duct cover use. Optional 6" or 12" Duct Cover 30" MIN. 36" MAX. 6" duct Hood cover ZV48 ZV36 ZV30 12" duct cover Dimensions (in inches) ZX48FWDC6 ZX48FWDC12 6H or 12H x 47-15/16W x 11-7/8D ZX36FWDC6 ZX36FWDC12 6H or 12H x 35-15/16W x 11-7/8D ZX30FWDC6 ZX30FWDC12 6H or 12H x 29-15/16W x 11-7/8D 75 Advance planning for professional hoods Installation height requirements Using duct cover accessories Restaurant-style hoods These vent hoods must be installed 30" min. to 36" max. above the standard 36”-high cooking surface. When installed with the warming shelf, allow 32" min. to 38" max. clearance. The exact hood installation height is determined by the ceiling height. One or more duct cover accessories may be required for your hood installation height. Use this chart to determine the size and number of duct cover accessories required depending on the use of the supplied warming shelf. 1. Measure the exact ceiling height. 2. Review the chart below to determine the range of hood installation heights that can be accomplished with a 6” or 12” duct cover accessory. • Increase or decrease hood installation height to accommodate the fixed 6” or 12” duct cover heights. • Duct covers may be stacked, in various combinations, to reach ceiling heights. Duct Cover(s) 10" Hood Height Duct Cover(s) 10" Hood Height 30" Min. 36" Max. Ceiling Height to Floor 32" Min. 38" Max. Ceiling Height to Floor Note: When determining the installation height, consideration must be given to the use of the warming shelf. 76 Restaurant-style hoods without warming shelf installed Restaurant-style hoods with warming shelf installed Possible Possible Duct Duct Actual hood hood cover cover ceiling installation installation height height* 6" 12" height* 6" 12" 7' 11" 31" 1 1 37" 1 8' 0" 32" 1 1 32" 1 1 8' 0" 38" 1 8' 1" 33" 1 1 33" 1 1 8' 2" 34" 1 1 34" 1 1 8' 3" 35" 1 1 35" 1 1 8' 4" 30" 2 8' 4" 36" 1 1 36" 1 1 8' 5" 31" 2 37" 1 1 8' 6" 32" 2 32" 2 8' 6" 38" 1 1 8' 7" 33" 2 33" 2 8' 8" 34" 2 34" 2 8' 9" 35" 2 35" 2 8' 10" 30" 1 2 8' 10" 36" 2 36" 2 8' 11" 31" 1 2 37" 2 9' 0" 32" 1 2 32" 1 2 9' 0" 38" 2 9' 1" 33" 1 2 33" 1 2 9' 2" 34" 1 2 34" 1 2 9' 3" 35" 1 2 35" 1 2 9' 4" 30" 3 9' 4" 36" 1 2 36" 1 2 9' 5" 31" 3 37" 1 2 9' 6" 32" 3 32" 3 9' 6" 38" 1 2 9' 7" 33" 3 33" 3 9' 8" 34" 3 34" 3 9' 9" 35" 3 35" 3 9' 10" 30" 1 3 9' 10" 36" 3 36" 3 9' 11" 31" 1 3 37" 3 10' 0" 32" 1 3 32" 1 3 10' 0" 38" 3 *Based on 36" countertop height. Note: Additional duct covers may be used to reach higher ceilings. monogram.com Installation height requirements Using duct cover accessories Tapered- and straight-sided hoods These vent hoods must be installed 30" min. to 36" max. above the standard 36"-high cooking surface. The exact hood installation height is determined by the ceiling height. One or more duct cover accessories may be required for your hood installation height. Use this chart to determine the size, number or combination of duct cover accessories required. 1. Measure the exact ceiling height. Duct Covers 18" Hood Height Ceiling Height to Floor Installation Height Professional hoods • Duct covers may be stacked, in various combinations, to reach ceiling heights. Custom hood inser ts • Increase or decrease hood installation height to accommodate the fixed 6" or 12" duct cover heights. Tapered- or straight-sided Straight-sided hoods with hoods only standard with full-width duct cover duct cover Duct Duct Actual Possible hood cover cover ceiling installation height height* 6" 12" 6" 12" 7' 11" 35" 1 1 8' 0" 30" 1 1 8' 0" 36" 1 1 8' 1" 31" 1 1 8' 2" 32" 1 1 8' 3" 33" 1 1 8' 4" 34" 1 1 8' 5" 35" 1 1 8' 6" 30" 1 1 1 1 8' 6" 36" 1 1 8' 7" 31" 1 1 1 1 8' 8" 32" 1 1 1 1 8' 9" 33" 1 1 1 1 8' 10" 34" 1 1 1 1 8' 11" 35" 1 1 1 1 9' 0" 30" 2 2 9' 0" 36" 1 1 1 1 9' 1" 31" 2 2 9' 2" 32" 2 2 9' 3" 33" 2 2 9' 4" 34" 2 2 9' 5" 35" 2 2 9' 6" 30" 1 2 1 2 9' 6" 36" 2 2 9' 7" 31" 1 2 1 2 9' 8" 32" 1 2 1 2 9' 9" 33" 1 2 1 2 9' 10" 34" 1 2 1 2 9' 11" 35" 1 2 1 2 10' 0" 30" 3 3 10' 0" 36" 1 2 1 2 10' 1" 31" 3 3 10' 2" 32" 3 3 10' 3" 33" 3 3 10' 4" 34" 3 3 *Based on 36" countertop height. Note: Additional duct covers may be used to reach higher ceilings. te l e s c o p i c d o w n d r a f t v e nt s 2. Review the chart at right to determine the range of hood installation heights that can be accomplished with a 6" or 12" duct cover accessory. chimney hoods Advance planning for professional hoods The serial plate is located behind the removable filters. 77 Advance planning for professional island hoods Installation height requirements Using duct cover accessories These vent hoods must be installed 30" min. to 36" max. above the standard 36"-high cooking surface. The exact hood installation height is determined by the ceiling height. A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine the need for a duct cover accessory. 1. Measure the exact ceiling height. Actual ceiling height 2. Review the chart at right to determine the range of hood installation heights that can be accomplished with or without an accessory kit. Duct Cover 20" for ZV42I 24" for ZV54I 30" Min. and 36" Max. Ceiling Height 36" to Countertop Accessory support frames with duct covers ZX42DC10—Optional accessory for ZV42I, for use with ceiling heights of 8' 6" to 10' 4". Kit includes telescoping support frames and duct covers. ZX54DC10—Optional accessory for ZV54I, for use with ceiling heights of 8' 6" to 10' 4". Kit includes telescoping support frames and duct covers. Installation heights ZV42 Possible hood Duct installation cover height* access. 7' 11" 30" Supplied 8' 0" 31" Supplied 8' 1" 32" Supplied 8' 2" 33" Supplied 8' 3" 34" Supplied 8' 4" 35" Supplied 8' 5" 36" Supplied 8' 6" 30" to 31" ZX42DC10 8' 7" 30" to 32" ZX42DC10 8' 8" 30" to 33" ZX42DC10 8' 9" 30" to 34" ZX42DC10 8' 10" 30" to 35" ZX42DC10 8' 11" 30" to 36" ZX42DC10 9' 0" 30" to 36" ZX42DC10 9' 1" 30" to 36" ZX42DC10 9' 2" 30" to 36" ZX42DC10 9' 3" 30" to 36" ZX42DC10 9' 4" 30" to 36" ZX42DC10 9' 5" 30" to 36" ZX42DC10 9' 6" 30" to 36" ZX42DC10 9' 7" 30" to 36" ZX42DC10 9' 8" 30" to 36" ZX42DC10 9' 9" 30" to 36" ZX42DC10 9' 10" 30" to 36" ZX42DC10 9' 11" 30" to 36" ZX42DC10 10' 0" 30" to 36" ZX42DC10 10' 1" 30" to 36" ZX42DC10 10' 2" 30" to 36" ZX42DC10 10' 3" 31" to 36" ZX42DC10 10' 4" 32" to 36" ZX42DC10 *Based on 36" countertop height. Installation heights ZV54 Possible hood Duct installation cover height* access. 30" 31" 32" 33" 34" 35" 36" 30" 30" to 31" 30" to 32" 30" to 33" 30" to 34" 30" to 35" 30" to 36" 30" to 31" 30" to 32" 30" to 33" 30" to 34" 30" to 35" 30" to 36" 30" to 36" 30" to 36" 30" to 36" 30" to 36" 31" to 36" 32" to 36" 33" to 36" 34" to 36" 35" to 36" 36" The serial plate is located behind the removable filters. 78 Supplied Supplied Supplied Supplied Supplied Supplied Supplied ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 ZX54DC10 monogram.com ZVC48 chimney hoods Custom insert hoods General features Patented installation process. Exclusive design allows an easy and secure connection with the ventilation duct from within the unit, without any modification to the exterior canopy. Halogen lighting. Four levels of clean, brilliant illumination suit any cooking task. Removable filters. Stainless steel mesh filters fit securely and lift out easily for safe cleaning in the dishwasher. Professional hoods Complete with blower, liner and filters. No additional components or accessory kits required. ZVC48LSS Overall dimensions (WxD in inches): 39-1/2" x 14" Amps @ 120VAC 10.05 Approx. shipping wt. (lbs.) 47 • Dual blowers • 8" round exhaust duct • Snap-in blower assembly • May be mounted onto a wall or in an island custom canopy ZVC30 and ZVC36 Custom hood inser ts Control with remote-mount option. At the time of installation, the control can be detached from the insert for mounting on a wall, countertop or other location. When positioned onboard, the panel is angled downward to allow easy adjustment of ventilation and light settings. 48" custom hood inser t 30" and 36" custom hood inser ts ZVC30LSS ZVC36LSS Overall dimensions (WxD in inches): 27-1/2" x 14" Amps @ 120VAC Approx. shipping wt. (lbs.) te l e s c o p i c d o w n d r a f t v e nt s Powerful ventilation. Single- and dual-blower ventilation with variable speed fan exhausts air at a rate of 640 and 1200 cubic feet per minute, making the inserts compatible with highperformance cooking appliances. 5.34 30 • 8" round exhaust duct • Snap-in blower assembly • May be mounted onto a wall or in an island custom canopy 79 Advance planning for custom hood inserts These hood inserts are designed for easy installation into a variety of custom hood applications. The hood attaches directly to the house ducting from within the unit. The supplied liner • The custom canopy must be constructed to house the insert sleeve. • The sleeve has locking clips on the bottom edge to hold it in place. The opening must be constructed of 3/4"-thick material to allow the locking clips to engage. A width ZVC30LSS 1-1/4" ZVC36LSS 4-1/4" ZVC48LSS 3-7/8" • The opening must be sized accurately to accept the insert sleeve and the supplied or custom liner. • Always maintain the 1/2" dimension at the rear to ensure correct alignment of the ductwork. • If you are not using the supplied liner you may construct a custom non-combustible liner. The custom liner must be constructed to the dimensions shown to fit the insert sleeve. • These hood inserts must use 8" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions. Refer to the installation instructions for details. B width 28-1/2" 34-1/2" 46-1/2" Custom cabinet opening width depth ZVC30LSS 26" 13-3/16" ZVC36LSS 26" 13-3/16" ZVC48LSS 38-3/4" 13-3/16" *Opening *Custom cabinet frame cutout opening must 3/4" thick material be 26" W x 13-3/16" D for 30" and 36" models and 38-3/4" W x 13-3/16" D for 48" models. To support the weight of the insert Custom sleeve and toinsert allow forliner the temporary locking clips to engage, the minimum Use the same opening cabinet dimensions recommended thickness of the bottom cabinet surface should be 3/4". to construct a custom liner. 3/4"-thick material must surround the opening. The 1/2" dimension at the rear is necessary to ensure duct alignment. Product dimensions and clearances Model ZVC48 Models ZVC30 and ZVC36 ZVC30 and ZVC36 ZVC48 39-1/2" 27-1/2" 14" 14" ZVC48 ZVC30 and ZVC36 29-1/2" 16-3/4" 14" 14" 1/2" 7/8" 25-3/4" 38-1/2" 13" 1/2" NOTE: Bottom edge of insert sleeve has a 7/8" flange on each side and The of the insert a 1/2"bottom flange onedge both front and back. sleeve has a 7/8" wide flange on the 1/2" 1/2" NOTE: 1/2" flange surrounds outside edge of insert sleeve. 13" 1/2" Note: 1/2" flange surround outside edge of insert sleeve. sides and 1/2" wide flange on the front and back. Remote location for the control The control panel may be removed from the hood and installed into a wall or countertop. A 30-ft. length of wire is supplied to accommodate most installation. A blanking plate covers the opening when the controls are removed. The overall size of the control panel is 4-1/4" wide and 2-1/4" deep. 80 3-11/16” 1-11/16” Control Cutout We recommend that the cutout in granite or other hard surfaces be made before the countertop is installed. monogram.com Telescopic downdraft vents chimney hoods General features Powerful ventilation. A 3-1/4" x 10" rectangular duct and a durable, stainless steel vent capture smoke and odors at the cooking surface. A variable-speed fan blower exhausts the air at a rate of 500 CFM. 30" telescopic downdraf t vent 682Dia23 ZVB36SHSS, ZVB36WHWW and ZVB36BHBB ZVB30SHSS and ZVB30BHBB Overall dimensions (WxHxD in inches): 36 x 8-1/2 x 2-1/8 Amps @ 120VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 30 x 8-1/2 x 2-1/8 Amps @ 120VAC Approx. shipping wt. (lbs.) 682Dia23 5 62 • 3-1/4" x 10" rectangular duct • Stainless steel vent body • Indoor remote blower kit • Outdoor remote blower kit with cover 5 60 • 3-1/4" x 10" rectangular duct • Stainless steel vent body • Indoor remote blower kit • Outdoor remote blower kit with cover Custom hood inser ts For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 36" telescopic downdraf t vent Important installation note: The installation of these downdraft vents in combination with any Monogram® cooktop requires an extra-deep countertop. The flat surface of the countertop must be deep enough, front to back, to accommodate the combined depth of the vent and cooktop together. Additional clearances required by UL from the cutout to the front edge of the countertop also vary by model and must be considered. Be sure to review the downdraft vent installation instructions carefully. These instructions provide exact cutout and countertop area requirements for the installation of the vent with each specific Monogram cooktop. te l e s c o p i c d o w n d r a f t v e nt s Remote blower placement installation kit. To reduce noise in the kitchen, an outdoor or indoor installation kit is offered for remote blower placement. Professional hoods Removable filters. Filters can be easily removed for safe cleaning in your dishwasher. 81 Advance planning for telescopic downdraft vents These downdraft vent systems are ideal for island and peninsula cooking centers because they retract nearly flush with the countertop. They may be installed with any Monogram® electric or gas cooktop except professional models. Both the 36" and 30" models are equipped with a separate raise/lower switch. The switch must be installed in a separate location outside of the vent and cooktop cutout. Separate raise/ lower switch A B 27" 30" models 36" models A 30" 36" B 28-1/2" 34" 682Dia21 2" 7-1/2" 2-1/4" 3-3/4" Countertop requirements Countertops must have a deep flat surface to accommodate the cooktop and the vent. Countertops with a rolled edge and backsplash may not provide the flat surface area required. Base cabinet requirements The base cabinet must be deep enough to accommodate the minimum clearance to the front edge of the countertop, the cooktop burner box and the vent. Downdraft vent and cooktop cutout The installation of these downdraft vents with any Monogram cooktop requires careful consideration. For accurate planning, review the individual dimension drawings for the combined vent and Monogram cooktop installation. 682Dia23 8-1/2" Lift Before you begin you must: 3-1/8" 2. Check to be sure that the total countertop depth required (including minimum cutout to front edge depth) allows enough space for a backsplash. 6-1/4" 1. Review countertop dimension illustrations to be sure you will have enough flat countertop surface depth. 3. Review the cabinet illustration. Check to be sure that the interior cabinet depth will house the cooktop burner box, the vent and the cutout clearance from the front. 10-1/2" 3-3/8" 7-1/8" 4. When countertop and cabinet depth present a problem, review Creative Solutions on page 85. 5. Read this section completely to accurately plan the installation location, clearances and ductwork requirements. 682Dia24 With careful planning you can achieve a custom look with minimal adjustments. The serial plate is located on the blower assembly. 82 monogram.com Creative solutions Optional accessories Against-the-wall installation Move the base cabinet forward, 3" to 5". Filler panels or complimentary moldings can be added to the exposed cabinet sides. JXRB67 Accessory for indoor remote location of the blower/ motor assembly. Use this kit when the blower and motor assembly will be located outside of the cabinet, such as below the cabinet floor. The assembly will fit between 16" floor joists. Maintain Cutout Clearances to Front Edge as Specified chimney hoods Advance planning for telescopic downdraft vents JXBC67 Outdoor cover accessory for remote installation of the blower/motor assembly on an outside wall. Ductwork Professional hoods Prepare the ductwork to vent to the outdoors. • Plan the shortest and straightest route for venting exhaust to the outdoors. • The maximum permissible length for the duct run is 150 feet. Base Sink Island or peninsula installation Use an extra-deep countertop. The countertop overhang at the front can be adjusted to meet setback to cutout requirements. 605Dia159 • The downdraft blower system is designed to use 3-1/4" x 10" duct. It can be transitioned to 6" round. • Install a wall cap or roof cap with damper at the exterior opening. Order the wall cap and any transition needed in advance. Venting options The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to a left- or rightside discharge. For even more flexibility, the entire blower and mounting plate can be adjusted 3-1/2" to the left or right sides. Countertop Overhang per Cooktop Clearances Must be Maintained End Panel Base Sink te l e s c o p i c d o w n d r a f t v e nt s Filler Panel Base Cabinet • Use metal ductwork only. Custom hood inser ts Filler Panel Cover Panel Decorative trim When the cutout to front edge of the countertop requirement is more than 2", add a bullnose trim to the front edge of the countertop. The additional trim allows the cooktop to be moved forward, providing additional countertop depth and interior cabinet space. Discharge Down (As Supplied) 682Dia49 605Dia160 Trim Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge 1-7/8" DOWNDRAFT VENT Discharge Left 682Dia50 Discharge Right 83 682Dia51 Advance planning for telescopic downdraft vents Electrical and gas locations • Install a standard electrical outlet within reach of the vent’s two-foot-long power cord. Locate the outlet inside the cabinet on the right side wall. Do Not Locate Gas or Electrical Connections Within Shaded Area Plan the placement of the electrical outlet and gas (if used) carefully. Gas or electrical outlets cannot be located on the back wall of the cabinet because they may interfere with the downdraft plenum. 29-1/2" 34" for 36" Models 28-1/2" for 30" Models • If the vent is installed in combination with a Monogram gas cooktop, it may operate from the same 120V standard duplex outlet. Electrical Outlet 12" Above Cabinet Floor • If the vent is installed in combination with a Monogram electric cooktop, the vent must operate from a separate 120V outlet. Cutouts and clearances Identify the cutout illustration for the Monogram® cooktop model you are installing. 682Dia47 ZGU385 gas cooktops with 36" vent 2-1/2" to Cutout 1-7/8" 3-3/8" Min. Cooktop Cutout to Rear Vertical Combustible Surface ZGU385 Cooktop 3/8" 1/4" Overlap 3/8" 1/8" Gap 21-11/16" Cutout Depth 23-5/16" Total Flat Surface Required at Center 34" Cooktop and Vent Cutout 7/16" Cooktop Overlap (1-1/4" at Center) 2-1/2" Min. Clearance to Cutout Front Edge of Countertop 1" Countertop cutout: Requires 23-5/16" flat countertop surface and 24-1/2" total countertop depth. 12" Min. Cutout to Side Walls 605Dia170 30-3/4" 1/8" gap 3/8" 28-1/2" cooktop and vent cutout 23-7/8" total flat surface required at center 7/16" cooktop overlap (1-1/4" at center) 2-1/2" min. clearance to cutout Front edge of countertop 2-7/8" min. cooktop cutout to rear verticle combustible surface zgu385_in_cabinet 1-7/8" ZGU384 Cooktop Countertop cutout: Requires 23-7/8" flat countertop surface and 24-7/8" total countertop depth. 12" min. cutout to wall, both sides 3/4" Thick Support Rail 20-3/8" 3/4" DOWNDRAFT VENT 22-3/4" to Back Wall 22" to Support Rail 24-3/4" ZGU36K gas cooktops with 36" vent 2-1/2" to Cutout 21-3/4" Cutout Depth 34" Cooktop and Vent Cutout 13/16" Cooktop Overlap (1-1/2" at Center) Front Edge of Countertop 84 2-1/2" Min. Clearance to Cutout 1-7/8" ZGU36 Cooktop 20-1/16" 1/4" Overlap 1/8" Gap 23-1/2" (SS) 23-3/8" (B,W) Total Flat Surface Required at Center 6" Min. Cutout to Side Walls Cabinet: Requires 23" inside cabinet depth. See Creative Solutions, install in an island or move cabinet base forward. zgu384_in_cabinet 2-1/4" Min. Cooktop Cutout to Rear Vertical Combustible Surface 36" Cabinet: Requires 22-11/16" inside cabinet depth. Remove rear support rail. 24-3/4" 2-1/2" to Cutout 2-3/4" 22-3/8" cutout depth 19-5/8" cooktop cutout depth DOWNDRAFT VENT 22-3/4" to Back Wall 22" to Support Rail ZGU384 gas cooktops with 30" vent 3/8" 3/4" Thick Support Rail 20-1/16" 36-3/4" 3/4" Countertop cutout: Requires 23-3/8" (B,W) 23-1/2" (SS) flat countertop surface. Requires 24-3/8" (B,W) and 24-1/2" (SS) total countertop depth. DOWNDRAFT VENT 22-3/4" to Back Wall 22" to Support Rail 24-3/4" 3/4" Thick Support Rail Cabinet: Requires 22-11/16" inside cabinet depth. Remove rear support rail. monogram.com Advance planning for telescopic downdraft vents 2-1/2" to Cutout 1-7/8" 36-1/8" (SS) 36" (Black) ZHU36 Cooktop 19-7/8" 1/4" Overlap 23" (SS) 22-7/8" (Black) Total Flat Surface Required 5/8" Cooktop Overlap (1-1/32" at Center) Front Edge of Countertop 2-1/2" Min. Clearance to Cutout Countertop cutout: Requires 22-7/8" (Black) 23" (SS) flat countertop surface. Requires 24-1/4" (Black) and 24-3/8" (SS) total countertop depth. 24-3/4" zhu36r_w_vent zhu36r_cutout ZHU30R induction cooktops with 30" vent 2-1/2" to Cutout 1-3/4" Min. Cooktop Cutout to Rear Vertical Combustible Surface 29-7/8" (SS) 1/4" Overlap 29-3/4" (Black) 28-1/2" Cooktop Area Cutout 5/8" Cooktop Overlap (1-1/32" at Center) 2-1/2" Min. Clearance to Cutout Front Edge of Countertop Countertop cutout: Requires 23-3/8" (Black) 23-1/2" (SS) flat countertop surface. Requires 24-3/4" (Black) and 24-7/8" (SS) total countertop depth. 2-1/2" to Cutout 36-1/8" (SS) 36" (B,W) 1/8" Gap 5/8" Cooktop Overlap (1-1/8" at Center) 2-1/2" Min. Clearance to Cutout 605Dia166 23" (SS) 22-7/8" (B,W) Total Flat Surface Required 2" Min. Cutout to Side Walls 1-7/8" ZEU36 Cooktop 19-7/8" 1/4" Overlap Front Edge of Countertop 22-3/4" to Back Wall 22" to Support Rail zhu30r_cutout 1-3/4" Min. Cooktop Cutout to Rear Vertical Combustible Surface 34" Cooktop and Vent Cutout Cabinet: Requires 23" inside cabinet depth. See Creative Solutions, install in an island or move cabinet base forward. 24-3/4" ZEU36R digital cooktops with 36" vent 2-3/4" 3/4" Thick Support Rail DOWNDRAFT VENT 2" Min. Cutout to Side Walls zhu30r_w_vent 21-3/4" Cutout Depth 19-1/8" Cooktop Cutout Depth 1-7/8" ZHU30R Cooktop 20-3/8" 3/4" 1/8" Gap 22-3/8" Cutout Depth 22-3/4" to Back Wall 22" to Support Rail 2" Min. Cutout to Side Walls 23-1/2" (SS) 23-3/8" (Black) Total Flat Surface Required at Center Cabinet: Requires 22-1/2" inside cabinet depth. Remove rear support rail. DOWNDRAFT VENT 3/4" Countertop cutout: Requires 22-7/8" (B,W) 23" (SS) flat countertop surface. Requires 24-1/4" (B,W) and 24-3/8" (SS) total countertop depth. te l e s c o p i c d o w n d r a f t v e nt s 34" Cooktop and Vent Cutout Custom hood inser ts 1/8" Gap 2-3/4" 21-3/4" Cutout Depth 19-1/8" Cooktop Cutout Depth 3/4" Thick Support Rail 3/4" Professional hoods 1-3/4" Min. Cooktop Cutout to Rear Vertical Combustible Surface chimney hoods ZHU36R induction cooktops with 36" vent DOWNDRAFT VENT 3/4" Thick Support Rail Cabinet: Requires 22-1/2" inside cabinet depth. Remove rear support rail. 22-3/4" to Back Wall 22" to Support Rail 24-3/4" 605Dia167 85 Advance planning for telescopic downdraft vents ZEU30R digital cooktops with 30" vent 2-1/2" to Cutout 1-3/4" Min. Cooktop Cutout to Rear Vertical Combustible Surface 29-7/8" (SS) 1/4" Overlap 29-3/4" (B,W) ZEU30 Cooktop 20-3/8" 3/4" 1/8" Gap 22-1/4" Cutout Depth 23-1/2" (SS) 23-3/8" (B,W) Total Flat Surface Required at Center 28-1/2" Cooktop Area Cutout 5/8" Cooktop Overlap (1-1/8" at Center) Front Edge of Countertop 2-1/2" Min. Clearance to Cutout Countertop cutout: Requires 23-3/8" (B,W) 23-1/2" (SS) flat countertop surface. Requires 24-3/4" (B,W) and 24-7/8" (SS) total countertop depth. 605Dia165 2-1/2" to Cutout 1-3/4" Min. Cooktop Cutout to Rear Vertical Combustible Surface 22-1/2" Total Flat Surface Required 34" Cooktop and Vent Cutout 5/8" Cooktop Overlap 2-1/2" Min. Clearance to Cutout 2" Min. Cutout to Side Walls 1-7/8" ZEU36 Cooktop 19-7/8" 1/4" Overlap 3/4" 1/8" Gap Front Edge of Countertop 22-3/4" to Back Wall 22" to Support Rail Countertop cutout: Requires 22-1/2" flat countertop surface and 24-3/8" total countertop depth. DOWNDRAFT VENT 22-3/4" to Back Wall 22" to Support Rail 24-3/4" 605Dia162 605Dia167 86 Cabinet: Requires 23" inside cabinet depth. See Creative Solutions, install in an island or move cabinet base forward. 24-3/4" ZEU36K electric cooktops with 36" vent 36" 3/4" Thick Support Rail DOWNDRAFT VENT 2" Min. Cutout to Side Walls 605Dia164 21-3/4" Cutout Depth 1-7/8" 3/4" Thick Support Rail Cabinet: Requires 22-1/2" inside cabinet depth. Remove rear support rail. monogram.com General features 2 1 4 7 trive ct ion ® wall oven s Electronic wall ovens with Trivection ® technology 3 5 6 8 9 0 LOWER OVEN UPPER OVEN LOCK CLEAR OFF OVEN LIGHT TIMER ON / OFF OVEN LIGHT CLEAR OFF Sophisticated styling. Sleek, modern design provides a striking look with clean lines and smooth, glass touch controls. Cooking versatility. In addition to Trivection technology, these ovens offer several other cooking methods and modes: baking, broiling, roasting and true European convection, as well as 24-hour delay bake, warm mode and proof mode. Full-size oven capacity. The spacious oven interior makes room for foods ranging from large roasts to rich, multi-tiered cake pans and everything in between. Halogen lighting. Two halogen lights illuminate your culinary work in progress. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 2 1 4 7 3 5 6 8 9 0 ZET3058SHSS 30" double oven with Trivection technology LOWER OVEN UPPER OVEN LOCK CLEAR OFF OVEN LIGHT TIMER ON / OFF CLEAR OFF OVEN LIGHT ZET3038SHSS 30" single oven with Trivection technology ZET3058SHSS and ZET3058BHBB ZET3038SHSS and ZET3038BHBB Overall dimensions (WxHxD in inches): 29-3/4 x 52-7/8 x 23-1/2 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 29-3/4 x 28-1/4 x 23-1/2 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) 37.1 32.2 333 • Flush appearance installation • Fits standard 30"-wide wall oven cabinets Advance planning for electronic wall ovens with Trivection technology convection wall ove n s Award-winning Trivection technology. Thermal, convection and microwave cooking processes work together to produce the ideal blend of taste and texture. Foods are prepared to delectable perfection—on average up to five times faster than a conventional oven. 24.6 21.2 199 • Flush appearance installation • Fits standard 30"-wide wall oven cabinets • Undercounter installation Electrical requirements Product rating is 120/208 or 120/240V, 60Hz. Connect to a 40-amp circuit for double ovens and 30-amp circuit for single ovens. The ovens must be connected to a supply circuit of the proper voltage and frequency and protected by a time-delay fuse or circuit breaker. Cutout and product dimensions 10-1/2" 27-1/4" Min. 27-5/16" Max. 23-1/2" 7" 23-1/2" Locate Junction Box 25" Min to 32" Max Above Cutout Floor, Within 7" of Right Rear Wall Locate Junction Box 12" Min to 18" Max Above Cutout Floor, Within 3-1/2" to 10-1/2" of Left Rear Wall 28-1/2" Min. 28-5/8" Max. 28-1/4" 51-13/16" Min. 51-15/16" Max. 28-1/2" Min. 28-5/8" Max. 52-7/8" 29-3/4" 32-1/2" 12" 30" Note: These ovens are not approved for stackable or side-by-side installations. 30" 29-3/4" Note: Most 30" wall cabinets can be used with this unit. The opening between the inside walls must be at least 28-1/2" wide. 87 Integrated LCD touchscreen, electronic dial and professional convection wall ovens Wall oven general features Integrated styling. (R and S models) Smooth, seamless exterior with tubular handle, electronic dial controls and expansive viewing window makes an unmistakable statement of quality and refinement. Professional styling. Sculptural lines, chamfered edges and robust, die-cast electronic dial controls give depth and dimension to the premium-grade stainless steel surface. Exclusive self-clean, full-extension oven racks. Racks glide in and out on stainless-steel ball bearings for easy access. The adjustable, heavy-duty, porcelain-coated racks can remain in the oven during the self-clean cycle. Halogen light columns. Two brilliantly illuminated columns on both sides of the oven enhance visibility, providing a clear view of food regardless of rack position. Reverse-Air convection system. Dedicated convection elements and a bidirectional fan provide consistent temperature throughout the oven. 30" LCD touchscreen single oven ZET1RMSS ZET1RMSS 30" LCD touchscreen double oven ZET2RMSS ZET2RMSS • LCD touchscreen with proximity sensor • Flush appearance installation • Fits standard 30"-wide wall oven cabinets • Approved for installation over warming drawers Six-element design. Two bake, two broil and two convection elements provide precise cooking control, with fast preheating. And, an electronic, low-voltage compensation feature boosts power in 208V applications. TIMER CLOCK COOK TIME PROBE DELAY START CLOCK COOK TIME DELAY START ZET1SMSS ZET1SMSS 30" integrated double oven ZET2SMSS ZET2SMSS 35.8 37.5 370 TIMER 30" integrated single oven For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. Overall dimensions (WxHxD in inches): 29-3/4 x 52-7/8 x 23-1/2 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) PUSH TO ENTER PUSH TO ENTER PROBE 4.4-cu.-ft total capacity. Generously sized interior accommodates even the largest meals, and true hidden bake elements add flexibility by allowing easy ash removal after the self-clean cycle. Double oven • LCD touchscreen with proximity sensor • Fits standard 30"-wide wall oven cabinets • Undercounter installation • Undercooktop installation • Approved for installation under specified cooktops, Advantium® ovens and over warming drawers • Approved for side-by-side installation • Flush appearance installation • Fits standard 30"-wide wall oven cabinets • Approved for installation over warming drawers • Flush appearance installation • Fits standard 30"-wide wall oven cabinets • Undercounter installation • Under cooktop installation • Approved for installation under specified cooktops, Advantium ovens and over warming drawers • Approved for side-by-side installation PUSH TO ENTER PUSH TO ENTER F PROBE TIMER CLOCK COOK TIME PROBE TIMER CLOCK COOK TIME Single oven Overall dimensions (WxHxD in inches): 29-3/4 x 28-1/4 x 23-1/2 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) 30" professional single oven ZET1PMSS 17.9 18.7 195 ZET1PMSS 30" professional double oven ZET2PMSS ZET2PMSS 88 • Professional aesthetic • Fits standard 30"-wide wall oven cabinets • Approved for installation over warming drawers • Professional aesthetic • Fits standard 30"-wide wall oven cabinets • Undercounter installation • Under cooktop installation • Approved for installation under specific cooktops, Advantium ovens and over warming drawers • Approved for side-by-side installation monogram.com Cutout and product dimensions 23-1/2" Min. The Integrated ovens offer contemporary styling with the signature Monogram® tubular handles. The professional oven design combines rugged stainless steel construction with refined styling. Both are designed to fit into a 30"-wide cabinet. Electrical requirements Product rating is 120/208 or 120/240V, 60Hz. Connect to a 40-amp circuit for double ovens and 20-amp circuit for single ovens. The ovens must be connected to a supply circuit of the proper voltage and frequency and protected by a time-delay fuse or circuit breaker. Installation below a countertop A single oven can be installed beneath countertops and below approved cooktops. Always refer to the cooktop installation instructions for electrical requirements and clearances. 1-1/2" Cabinet Top 25" Locate Junction Box Within 5" of the Right Rear Wall Locate Junction Box 47" Above Cutout Floor, Within 5" of Right Rear Wall 51-13/16" Min. 51-15/16" Max. 12" 30" 23-1/4" Recessed Depth 29-3/4" Integrated double oven ZET2SMSS Stainless steel Professional double oven ZET2PMSS Stainless steel 23-1/2" Min. 27-1/4" Min. 27-5/16" Max. 23-1/2" Min. 52-7/8" LCD touchscreen double oven ZET2RMSS Stainless steel 36" Countertop Height 28-1/2" Min. 28-5/8" Max. 28-1/2" Min. 28-5/8" Max. Locate Junction Box 22" Above Cutout Floor, Within 5" of Right Rear Wall 27-1/4" Min. 28-1/2" Min. 28-5/8" Max. 27-5/16" Max. 28-1/4" Elevate the oven floor to desired height. The support must be level, rigidly mounted and capable of supporting 175 lbs. 23-1/4" Recessed Depth 32-1/2" 625Dia9 2″ (5.1 cm) Min. 29-3/4" 30" Side-by-side installations Install two ovens in separate cutouts. Allow 2" minimum between the cutouts. Cutout – Observe all dimensions and requirements. convection wall ove n s The LCD touchscreen ovens with proximity sensor provide easy, intuitive access to oven functions and options trive ct ion ® wall oven s Advance planning for LCD touchscreen, integrated and professional convection wall ovens Cutout – Observe all dimensions and requirements. LCD touchscreen single oven ZET1RMSS Stainless steel Integrated single oven ZET1SMSS Stainless steel Professional single oven ZET1PMSS Stainless steel 89 Electronic convection wall ovens General features LOWER OVEN BAKE ROASt cONV DELAY StARt StARt 1 RAcK cOOK tIME MULt BAKE BROIL WARM PROOF PROBE SELF cLEAN cLEAR OFF cONV cONV HIGH LOW BAKE BAKE cONV StARt ROASt 1 RAcK DELAY StARt cOOK tIME MULt cLEAR OFF BAKE BROIL WARM PROOF PROBE SELF cLEAN cONV UPPER OVEN BAKE StD LOW 2 1 3 4 5 6 7 cONV HIGH LOW StD LOW tIMER 0 9 8 HIGH LOW LOcK LOWER OVEN Sophisticated styling. Seamless, hand-finished doors and smooth controls offer a look of modern refinement. BAKE ROAST CONV DELAY START START 1 RACK COOK TIME MULT BAKE BROIL WARM PROOF PROBE SELF CLEAN CLEAR OFF CONV CONV HIGH LOW BAKE BAKE CONV START ROAST COOK TIME 1 RACK DELAY START MULT CLEAR OFF BAKE BROIL WARM PROOF PROBE SELF CLEAN CONV UPPER OVEN BAKE STD LOW 1 2 3 6 5 4 7 8 0 9 CONV HIGH LOW STD LOW TIMER HIGH LOW LOCK Electronic glass touch controls. A gentle touch allows you to easily select the desired cooking function: convection bake or roast, variable or closed-door broiling, 24-hour delay bake, warm mode or proof mode. Reverse-Air convection. A bi-directional fan delivers exceptionally consistent cooking performance, allowing heated air to circulate on all sides of food. Self-clean racks. Porcelain-coated racks are designed to be left in the oven during the self-clean cycle for effortless cleaning. Halogen lighting. Two halogen lights illuminate your culinary work in progress, putting it into bright, clear perspective. Concealed bake element. A smooth surface simplifies ash removal after the self-clean cycle. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. ZEt958SMSS oven 30" double 27" double oven ZEK958SMSS ZET958SMSS, ZET958WMWW and ZET958BMBB ZEK958SMSS and ZEK958BMBB Overall dimensions (WxHxD in inches): 29-3/4 x 52-7/8 x 23-1/4 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 26-5/8 x 51 x 23-1/4 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) 37.5 32.6 260 • Flush appearance installation • Fits standard 30"-wide wall oven cabinets • Approved for installation over warming drawers • Flush appearance installation • Fits standard 27"-wide wall oven cabinets • Approved for installation over warming drawers OPTIONS OPTIONS OVEN OVEN DELAY START CONV BAKE MULT CONV BAKE 1 RACK BROIL BAKE HIGH LOW CONV ROAST START WARM PROOF CLEAR OFF DELAY START PROBE 2 3 4 5 6 7 8 0 9 SELF CLEAN STD LOW TIMER ON OFF CONV CONV BAKE BAKE ROAST START MULT 1 RACK BAKE BROIL WARM PROOF CLEAR OFF CONV COOK TIME 1 HIGH LOW COOK TIME 1 2 3 4 5 6 7 8 0 9 PROBE SELF CLEAN STD LOW TIMER ON OFF LOCK LOCK 30" single oven 27" single ZEK938SMSSoven ZET938SMSS, ZET938WMWW and ZET938BMBB ZEK938SMSS and ZEK938BMBB Overall dimensions (WxHxD in inches): 29-3/4 x 28-1/4 x 23-1/4 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) Overall dimensions (WxHxD in inches): 26-5/8 x 29 x 23-1/4 Amps @240VAC 208VAC Approx. shipping wt. (lbs.) ZET938SMSS 19 16 135 • Flush appearance installation • Fits standard 30"-wide wall oven cabinets • Undercounter installation • Approved for installation under specified cooktops, under Advantium® ovens and over warming drawers • Approved for side-by-side installation 90 28 25 164 15 13 100 • Flush appearance installation • Fits standard 27"-wide wall oven cabinets • Undercounter installation • Approved for installation under specified cooktops, under Advantium ovens and over warming drawers monogram.com trive ct ion ® wall oven s Advance planning for electronic convection wall ovens Electrical requirements Product rating is 120/208 or 120/240V, 60Hz. Connect to a 40-amp circuit for double ovens and 20-amp circuit for single ovens. The ovens must be connected to a supply circuit of the proper voltage and frequency and protected by a time-delay fuse or circuit breaker. Cutout and product dimensions 23-1/2" 10" Locate Electrical Outlet Within 10" of Left Side of Opening and 44" Above Cutout Floor or 5" Below Cutout Floor Locate Junction Box 47" Above Cutout Floor, Within 5" of Right Rear Wall 51-13/16" Min. 51-15/16" Max. 28-1/2" Min. 28-5/8" Max. 12" 52-7/8" 49-11/16" Min. 50-1/8" Max. 13-1/4" 30" 30" double ovens ZET958SMSS Stainless steel ZET958BMBB Black ZET958WMWW White 23-1/4" Recessed Depth 29-3/4" 27-1/4" Min. 27-5/16" Max. 28-1/4" 23-1/4" Recessed Depth 32-1/2" 23-1/4" Recessed Depth 26-5/8" 23-1/2" Min. 27-5/8" Min. 28-1/8" Max. Locate Electrical Outlet Within 10" of Left Side of Opening 22" Above Cutout Floor or 5" Below Cutout Floor 25" Min. 25-1/4" Max. 29" 23-1/4" Recessed Depth 32-1/2" 26-5/8" 27" 30" single ovens ZET938SMSS Stainless steel ZET938BMBB Black ZET938WMWW White 27" single ovens ZEK938SMSS Stainless steel ZEK938BMBB Black 605Dia92 30" single oven side-by-side installations Install two ovens in separate cutouts. Allow 2" minimum between the cutouts. 2″ (5.1 cm) Min. 27" 29-3/4" 30" Cutout – Observe all dimensions and requirements. 51" 605Dia93 Locate Junction Box 22" Above Cutout Floor, Within 5" of Right Rear Wall 28-1/2" Min. 28-5/8" Max. 25" Min. 25-1/4" Max. 27" double ovens ZEK958SMSS Stainless steel ZEK958BMBB Black 605Dia91 23-1/2" convection wall ove n s 23-1/2" 605Dia94 Cutout – Observe all dimensions and requirements. 91 Advance planning for built-in cooking products Monogram built-in ovens and warming drawers are designed for installation flexibility and to coordinate with and complement other Monogram appliances. Single ovens can also be installed below approved Monogram cooktops. Review the following chart for approved combinations. Approved single oven and cooktop installation combinations 30" integrated ZET1S and ZET1R 30" professional ZET1P 30" touch ZET938 30" Trivection® ZET3038 Gas cooktops 30" stainless steel ZGU384 • • • 36" stainless steel ZGU385 • • • 36" gas-on-glass ZGU36K • • • Induction cooktops 30" induction ZHU30 • • • 36" induction ZHU36 • • • Electric cooktops 30" digital ZEU30R • • 36" digital ZEU36R • • • 36" electric ZEU36K • • • Note: Built-in wall ovens with Advantium® Speedcook technology cannot be installed below a countertop. The Trivection oven cannot be installed below a cooktop, but it may be installed below a countertop. 92 Warming drawer ZTD/ZKD910 • • • • • • monogram.com advantium ® Speedcook wa ll oven Wall oven with Advantium ® Speedcook technology General features SPEED COOK POWER LEVEL TIMER MICRO WAVE MANUAL COOK OPTIONS HELP MICRO EXPRESS REPEAT LAST TU R N T O SE START PAUSE BACK RECIPE PR E R Sophisticated styling. The overall look is sleek. The oven’s bold, horizontal lines are set off by simple graphics and a tubular handle on the pull-down door. CLEAR OFF ES S T O E N T Speedcook technology. 4500-watt halogen cooking system uses heat generated from light to rapidly cook the outside of foods, sealing in natural juices. At the same time, heat penetrates the surface, evenly cooking the inside. Easy-to-use controls. The control dial smoothly turns in both directions, making it easy to select from more than 100 preprogrammed recipes. For added convenience, Demo and Help programs guide you through the simple process of choosing a programmed recipe or customizing your own. Full-function microwave oven. At the touch of a button, the oven converts to a high-performance, sensor-controlled microwave. Advantium ZSC2001FWW/BB Speedcook oven microwave ove n s Powerful performance. Oven-quality foods cook in up to eight times faster than a conventional oven, with no preheating required. ZSC2001FSS, ZSC2000FWW and ZSC2000FBB Overall exterior dimensions (excluding handles) (WxHxD in inches): 29-25/32 x 21-7/8 x 15-27/32 Amps @240VAC 26.3 208VAC 22.7 Approx. shipping wt. (lbs.) 101 warming drawer s • 30" oven cabinet width required • Approved for installation above a single wall oven or warming drawer Wall oven with Advantium 120 Speedcook technology General features Sophisticated styling. Clean lines offer a stylish, modern look that coordinates beautifully with other Monogram® built-in cooking products. OVEN MICROWAVE SPEED COOK BAKE BROIL COOK EXPRESS FAVORITE RECIPES CUSTOM WARM PROOF DEFROST REHEAT TIMER SPEED COOK START PAUSE CLEAR OFF BACK HELP POWER TEMP OPTIONS Remarkable versatility. Multiple cooking options create four ovens in one—Speedcook, true European convection, sensor microwave and warming ovens—to bake, broil, brown, roast, warm and proof foods. Spacious interior. Rounded oven cavity and 16" turntable allow full and continual rotation of a 9" x 13" casserole dish. Removable oven rack offers the convenience of multi-level cooking. Installation flexibility. Ovens can be installed in a 27" or 30" wall cabinet (with included trim kit). ZSC1001JSS Advantium 120 Speedcook oven ZSC1001KSS and ZSC1000KBB Overall exterior dimensions (excluding handles) (WxHxD in inches): 26-3/4 x 18-5/8 x 21-1/2 (27" cabinet) 29-3/4 x 18-5/8 x 21-1/2 (30" cabinet) Amps @120V 13.8 Approx. shipping wt. (lbs.) 100 • Installs in 30" or 27" wall oven cabinet, no kit required • Approved for installation above a single wall oven or warming drawer Dual -burn er out d oor c ookt op Powerful performance. Oven-quality foods cook up to four times faster than a conventional oven, with no preheating required. 3 6" out doo r c ook ing cent e r s Speedcook technology. Halogen-light system speedcooks your favorite foods to delicious perfection—in minutes, with no preheating. 93 Advance planning for wall oven with Advantium ® 240 Speedcook technology The Monogram® Advantium built-in oven can be installed directly into a wall, 30"-wide wall oven cabinetry. Install it alone, with a single oven or with a warming drawer. Create a complete cooking center by installing the Advantium with both. • This oven must be installed at least 36-3/4" above the floor. • For personal safety, this oven cannot be installed in a cabinet arrangement such as an island or peninsula. • This oven is not approved for installation below a countertop, side by side or stacked. Electrical requirements Product rating is 120/208 or 120/240V, 60Hz, 30 amps. This product must be connected to a supply circuit of the proper voltage and frequency and protected by a time-delay fuse or circuit breaker. Advantium 240 oven installed above a Monogram single wall oven When installed over a single oven or a warming drawer, allow at least 2" between the two openings. This separation will provide clearance for bottom overlap of the Advantium oven and top overlap of the single oven or warming drawer. • The Advantium oven and single oven combination can use separate electrical junction boxes or a single junction box connected to a 50-amp circuit. 30" *The middle rail separating the two openings may need to be larger than the 2" min. shown. 24" Min. Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides 28-1/2" 21" 2" Min. Per Oven Requirement Cutout and product dimensions *45-1/4" Advantium 240 oven installed alone Order a 30"-wide single oven cabinet or cut the opening in a wall to the dimensions shown. 30" 19" Min 28-7/16" 28-1/2" Advantium 240 oven installed above a Monogram single wall oven and a warming drawer An anti-tip block must be installed at the rear of the warming drawer opening. See installation instructions for complete details. 605Dia87 15" (Recessed Portion) 21" 21-7/8" 15-27/32" 29-25/32" • The Advantium oven and single oven combination can use separate electrical junction boxes or a single junction box connected to a 50-amp circuit. • The warming drawer must be supplied with a separate 120V, 60Hz, properly grounded receptacle. 36-3/4" Min. Required Advantium 240 oven installed above a Monogram warming drawer An anti-tip block must be installed at the rear of the warming drawer opening. Again, see installation instructions for complete details. 605Dia85 • The warming drawer must be supplied with a separate 120V, 60Hz, properly grounded receptacle. Note: Additional clearance between cutouts may be required. 30" 28-1/2" 21" 9-1/4" 36-3/4" Min. 94 24" Min. Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides 2" Min. Install 2 x 4 or 2 x 2 Runners or Solid Bottom, Must Support 100 lbs. 605Dia86 Note: Additional clearance between cutouts may be required. Check to be sure the oven supports above the warming drawer location do not obstruct the required interior 23-1/2" depth and 9-1/4" height. See each specific product’s installation instructions for details. 30" 21" 24" Min. 28-1/2" Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides 2" Min. Per Oven Requirement 2" Min. 45-1/4" 9-1/4" 605Dia112 monogram.com • For personal safety, this oven cannot be installed in a cabinet arrangement such as an island or peninsula. • This oven is not approved for installation below a countertop, side by side or stacked. • The Advantium 120 oven and single oven combination must be supplied with separate electrical connections. 27" or 30" Electrical requirements Product rating is 120 volt, 60 Hz, 15 amp circuit and draws 1.8 kilowatts. It must be connected to a supply circuit of the proper voltage and frequency and protected by a time-delay fuse or circuit breaker. T he middle rail separating the two openings may need to be larger than the 2" min. shown. 23-1/2" 25-1/8" Min. 25-1/4" Max. 17-1/2" Advantium 120 oven installed alone Order a 27" or 30"-wide single oven cabinet or cut the opening in a wall to the dimensions shown. warming drawer s 21-1/2" 17-1/2" 45-1/4" Advantium 120 oven installed above a Monogram single wall oven and a warming drawer An anti-tip block must be installed at the rear of the warming drawer opening. See installation instructions for complete details. 23-1/2" 25-1/8" Min. 25-1/4" Max. Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides 2" Min. Per Oven Requirement Cutout and product dimensions 27" or 30" microwave ove n s • This oven must be installed at least 36-3/4" above the floor. Advantium 120 oven installed above a Monogram single wall oven When installed over a single oven or a warming drawer, allow at least 2" between the two openings. This separation will provide clearance for bottom overlap of the Advantium oven and top overlap of the single oven or warming drawer. • The warming drawer and the Advantium 120 oven must be supplied with separate 120V, 60Hz, properly grounded receptacles. 18-5/8" 6" Locate Outlet Box in the Shaded Area 26-3/4" 36-3/4" Min. 18-5/8" Construct Base Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners all Four Sides 29-3/4" with side trim Advantium 120 oven installed above a Monogram warming drawer An anti-tip block must be installed at the rear of the warming drawer opening. Again, see installation instructions for complete details. • The warming drawer must be supplied with a separate 120V, 60Hz, properly grounded receptacle. 27" or 30" T he middle rail separating the two openings may need to be larger than the 2" min. shown. 23-1/2" 25-1/8" Min. 25-1/4" Max. 17-1/2" 9-1/4" 36-3/4" Min. Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides 2" Min. Install 2 x 4 or 2 x 2 Runners or Solid Bottom, Must Support 100 lbs. Note: Additional clearance between cutouts may be required. Check to be sure the oven supports above the warming drawer location do not obstruct the required interior depth and height. See each specific product’s installation instructions for details. 27" or 30" 25-1/8" Min. 25-1/4" Max. Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides 17-1/2" 2" Min. Per Oven Requirement 2" Min. 45-1/4" Electrical location Locate a recessed outlet within 6" of either side and at least 9" above the cutout floor. The serial plate is located on the oven cavity flange, behind the door. 23-1/2" 3 6" out doo r c ook ing cent e r s 9" 9-1/4" 27" or 30" 23-1/2" 25-1/8" Min. 25-1/4" Max. 17-1/2" 6" 9" Locate Outlet Box in the Shaded Area 36-3/4" Min. Dual -burn er out d oor c ookt op The Monogram Advantium 120 built-in oven can be installed directly into a wall, a 27"-wide or 30"-wide wall oven cabinetry. Install it alone, with a wall oven or with a warming drawer. advantium ® Speedcook wa ll oven Advance planning for wall oven with Advantium 120 Speedcook technology Construct Base Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners all Four Sides 95 26-3 wit Microwave ovens MICROWAVE CONVECTION SENSOR POPCORN SENSOR REHEAT AUTO DEFROST MICRO COOK COMBINATION SENSOR BEVERAGE SENSOR COOK TIME DEFROST TEMP COMBINATION COOK/HOLD ROAST PROBE PROBE SELECTIONS 1 COOK 2 3 4 EXPRESS COOK EXPRESS COOK EXPRESS COOK EXPRESS COOK 6 7 8 9 COOK 5 EXPRESS COOK 0 DISPLAY ON/OFF POWER LEVEL DELAY START START ADD 30 SEC MINUTE CLEAR OFF REMINDER LEVEL KITCHEN TIMER CODES 0-1-2-3 SENSOR COOKING BEVERAGE REHEAT BEVERAGE POPCORN POTATO CHICKEN FISH TIME COOK AUTO DEFROST TIME DEFROST 1 EXPRESS COOK 4 EXPRESS COOK 7 POWER LEVEL 2 EXPRESS COOK 5 EXPRESS COOK 8 0 3 EXPRESS COOK 6 EXPRESS COOK 9 SENSOR COOKING ADD 30 SEC POPCORN DISPLAY ON/OFF START PAUSE CLEAR OFF HELP BEEPER VOLUME DELAY START AM/PM REMINDER BEVERAGE REHEAT POTATO VEGETABLE CHICKEN FISH GUIDE BEHIND DOOR DEFROST AUTO/TIME TIME COOK CLOCK SCROLL SPEED 1 EXPRESS COOK TIMER ON/OFF 4 EXPRESS COOK 7 POWER LEVEL 2 EXPRESS COOK 5 EXPRESS COOK 3 EXPRESS COOK START PAUSE 6 EXPRESS COOK 8 HELP 9 ADD 30 SEC 0 CLEAR OFF DISPLAY ON/OFF TIMER REMINDER DELAY START CLOCK AM/PM TURNTABLE ON/OFF Sensor Microwave Oven ZMC1095SF Microwave/ convection oven ZE216OSF(trim) Countertop microwave oven CompactZEM20OSF microwave oven ZMC1095SF, ZMC1095WF and ZMC1095BF ZE2160SF ZEM200SF, ZEM200WF and ZEM200BF Oven Cavity (cu. ft.) 1.0 Power rating 800W Overall dimensions* (WxHxD in inches): 26-3/4 x 18-5/8 x 16-3/8 Amps @120VAC 13.0 Approx. shipping wt. (lbs.) 84 Oven Cavity (cu. ft.) 2.1 Power rating 1200W Overall dimensions (WxHxD in inches): 24 x 14 x 19-1/2 Amps @120VAC 13.9 Approx. shipping wt. (lbs.) 51 Oven Cavity (cu. ft.) 1.0 Power rating 800W Overall dimensions* (WxHxD in inches): 23-25/32 x 11-11/64 x 12-55/64 Amps @120VAC 11.5 Approx. shipping wt. (lbs.) 43 • Can be installed In a 30" or 27" wall oven cabinet, no kit required • Can be installed over a 30" or 27" wall oven • Built-in kit available for 30" or 27" installation • Built-in kit available for 27" installation *Height includes feet *Depth excludes handle Built-in microwave/convection oven general features Countertop and compact microwave oven general features Sophisticated styling. Built-in design offers stylish, integrated appearance. Sophisticated styling. Electronic touch controls and a large viewing window make a sleek, modern statement. Three modes. The microwave/convection oven offers three ways to cook: microwave, convection, or a combination of both. Sensor cooking. An electronic sensor monitors the level of steam released by food and automatically adjusts cooking time to deliver optimal results. Microwave/Convection cooking. The convection mode uses a separate heating element and fan built into the rear wall to circulate air. This process allows gorgeous browning and roasting. You can also convection-cook with the microwave function for faster results, or use the oven for microwaving only. Flexible installation. Optional built-in kit allows cabinet or wall installation, and an optional hanging kit allows you to mount unit under a cabinet. Sensor cooking. An electronic sensor monitors the level of steam released by food and automatically adjusts cooking time to deliver optimal results. 96 For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. monogram.com Built-in microwave/convection ovens Compact microwave oven The Monogram built-in microwave/convection oven is sized to fit a 27"-wide cabinet. Side trim pieces are supplied for installation in a 30" cabinet. This microwave oven can be used on a countertop or hung from kitchen wall cabinets. The hanging kit is packed with the microwave oven. • This microwave oven must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit and protected by a 15- or 20-amp circuit breaker or time-delay fuse. • This microwave oven can also be built into 27"-wide cabinetry. Order JX827SMSS for stainless steel, JX827DMBB for black and JX827DMWW for white models. 6" Locate electrical outlet on back wall 17" min. outside and 19" min. inside cutout. 18" 16-3/8" Excluding Handle 25-1/4" 8" Locate Outlet Box in the Shaded Area 17-1/2" 696Dia1436" Min. 18-5/8" 27" or 30" Cabinet 26-3/4" • This microwave oven must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit and protected by a 15- or 20-amp circuit breaker or time-delay fuse. microwave ove n s ® advantium ® Speedcook wa ll oven Advance planning for microwave ovens 18" Locate Electrical Outlet on Back Wall 16" Min. Outside and 18" Min. Inside Cutout 24-7/8"±1/16" 12-1/2" 16-1/4" 15"±1/16" 18-5/8" 26-1/8" ZMC1095SF Stainless steel ZMC1095BF Black ZMC1095WF White warming drawer s 29-3/4" with side trim 27" 696Dia13 Countertop microwave oven This large microwave oven is encased in stainless steel. It can be used on the countertop or built in using optional kits. Order JX2127SH for installation into a 27"-wide cabinet. Order JX2130SH for installation into a 30" cabinet. Kits must be ordered separately from your Monogram dealer. ZEM200SF Stainless steel ZEM200BF Black ZEM200WF White 605Dia101 Locate Electrical Outlet on Back Wall 19-1/2" Min. Outside and 22" Min. Inside Cutout 3 6" out doo r c ook ing cent e r s • This microwave oven must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit and protected by a 15- or 20-amp circuit breaker or time-delay fuse. 25-1/2" 19" 19" 16-3/4" B A B A Dual -burn er out d oor c ookt op ZE2160SF JX2127SH JX2130SH 27" 30" 26-5/8" 29-3/4" 605Dia100 Note: The trim frame protrudes forward of cabinetry to allow air flow from the top, bottom and sides of the frame. Allow 1" clearance beyond the edge of the trim frame to provide proper air flow. 97 Warming drawers ZTD910BB ZTD910BB General features Sophisticated styling. Built-in design with hidden controls offers a look of understated elegance. For a personal statement, customize the drawer with a cabinet-compatible wood panel and your choice of handles. Temperature settings. Monogram® warming drawers offer a range of temperature options, from a proof setting (approximately 75°F) to a high setting (approximately 230°F). Humidity control. By opening or closing the warming drawer vent, you can keep foods crisp or maintain moisture. Practical details. The design of the half rack not only distributes heat evenly, but it also provides fifty percent more surface area for stacking plates and food. Installation versatility. All 30" and 27" warming drawers are UL listed for use with Monogram wall ovens and cooktops. Three-pan set. A set of three covered pans allows a choice of sizes for any dish: one 6-quart pan and two 3-quart pans. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 30" warming drawer 27" warming drawer ZTD910SFSS, ZTD910WFWW and ZTD910BFBB ZKD910SFS and ZKD910BFBB Overall dimensions (WxHxD in inches): 30 x 10-1/2 x 23-1/4 Amps @120VAC Approx. shipping wt. (lbs.) Overall exterior dimensions (WxHxD in inches): 26-3/4 x 10-1/2 x 23-1/4 Amps @120VAC Approx. shipping wt. (lbs.) • Optional custom wood panel kit • Side-by-side installation • Undercounter installation • Under wall oven installation • Under cooktop installation 15 65 • Optional custom wood panel kit • Side-by-side installation • Undercounter installation • Under wall oven installation • Under cooktop installation Advance planning for warming drawers Electrical requirements Custom panels and handles Product rating is 120V, 60Hz, and connected to an individual, properly grounded branch circuit and protected by a 15- or 20-amp circuit breaker or time-delay fuse. Two warming drawers installed side by side can operate from the same duplex outlet. The drawer fronts can be removed and replaced with a custom panel to match surrounding cabinetry. • Order ZXD30B for 30"-wide models and ZXD27B for 27" models. These kits must be ordered separately from your Monogram supplier. • The tubular handle may be reinstalled onto the custom panel (longer screws will be required) or replaced with a custom handle of your choice. 26-3/4" for 27" Models 30" for 30" Models Drill 5/16" Dia. 10-1/2" Through Custom Panel For Lamp Jewel 1-3/4" 605Dia102 98 1-13/16" 15 59 monogram.com Installation below a single or double oven The warming drawer may be installed below a single or double oven. Observe the 1" minimum clearance above the toekick, or 5" above the floor. Installation below a countertop The warming drawer may be installed beneath a countertop. Install the drawer 5" minimum above the floor or 1" above the toekick. The recommended distance from the floor to the bottom of the cutout is 23-1/4" for undercounter installation. Installation below a cooktop The warming drawer is approved for installation below specified cooktop models. A solid barrier and an air gap between the cooktop and the warming drawer are required. See note below. 2" Min. 9" Allow 5/8" Overlap on All Sides 9-1/4" 23-1/4" A 1" Min. Above Toekick or Adjust to Oven Installation Height Dim. A 28-1/2" 25-1/2" B Dim. B 30" 26-3/4" 605Dia110 Note: Additional clearance between cutouts may be required. Check to be sure that oven supports, above the warming drawer location, do not obstruct the required interior 23-1/2" depth and 9-1/4" height. 23-1/2" Min. Inside Double oven Electrical Outlet 42" Max. From Right Side. 1-1/2" Cabinet Top 25" Solid Barrier See Note Electrical Outlet Flush With Side of Cabinet 7" Max. 7" 1" Min.* 9-1/4" A Solid Barrier Allow 5/8" Overlap on All Sides 23-1/2" Min. 2" Min. 9" 9-1/4" 10-1/2" 1" Min. Above Toekick Dim. A 28-1/2" 25-1/2" B Dim. B 30" 26-3/4" 605Dia111 1/4" Air Gap 36" Countertop Height w elo nB tiower a l tal ra Ins a D Install a Solid Barrier and a 1/4" Air Gap Above Warming Drawer 23-1/4" A ZTD910 ZKD910 Electrical Outlet 16" Max. From Left Side. Install 2x4 or 2x2 Anti-Tip Block Against Rear Cabinet Wall 9" From Floor to Bottom of Block 9" Oven Cutout 2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9" From Floor to Bottom of Block Installation below a cabinet drawer The warming drawer may be installed beneath a cabinet drawer. In this installation, a solid barrier should be installed above the warming drawer to block access. Use any solid material such as 1/4"-thick plywood. Allow at least 1/4" air gap between the barrier and the top of the warming drawer. warming drawer s Oven Cutout microwave ove n s 605Dia107 10-1/2" ZTD910 ZKD910 Side-by-Side Installation 3 6" out doo r c ook ing cent e r s 2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9" From Floor to Bottom of Block 2" Min. 27" warming drawers ZKD910SFSS Stainless steel ZKD910BFBB Black 23-1/2" Min. Inside Single oven Side-by-side installation Install two warming drawers in separate cutouts. Allow 2" minimum between cutouts. ZTD910 ZKD910 Dim. A 28-1/2" 25-1/2" Dim. B 30" 26-3/4" Dual -burn er out d oor c ookt op 30" warming drawers ZTD910SFSS Stainless steel ZTD910BFBB Black ZTD910WFWW White advantium ® Speedcook wa ll oven Advance planning for warming drawers 605Dia109 *Note: When installing the warming drawer below a cooktop, a solid barrier must be installed at least 1" from the lowest point of the bottom of the cooktop burner box to the top of the cutout. Use any solid material such as 1/4"-thick plywood. Allow at least 1/4" air gap between the barrier and the top of the warming drawer. 99 36" outdoor cooking centers General features Gourmet Radiant™ trays. Beneath the grill racks, these uniquely designed trays ensure even heat distribution. They also reduce grease flare-ups, eliminate the need for lava rocks or briquettes and remove easily for cleanup. Porcelain-coated, cast-iron grill burners. Two 20,000-BTU “H” burners provide the power necessary to evenly heat the entire grilling area. Heavy-duty grill racks. The heavy, heat-retaining grill racks are porcelain-enameled for easy cleaning and long life. ROTISSERIE GRILL IGNITOR GRILL ROTESSERIE IGNITOR SMOKER GRILL IGNITOR GRILL SMOKER IGNITOR GRILL IGNITOR 36" outdoor cooking center 605Dia187 ZGG36N31CSS (natural gas) Brass valves. Burner controls are mounted on durable brass valves, ensuring long life in an outdoor environment. ZGG36L31CSS (liquid propane) Infrared rotisserie system. A ceramic infrared burner, mounted behind the motorized rotisserie, reaches cooking temperature in just 30 seconds. Overall dimensions (WxHxD in inches): 35-7/8 x 22 x 25-3/8 Approx. shipping wt. (lbs.) Built-in smoker system. Includes an independent 5000-BTU burner with variable temperature control and a full-extension, slide-out drawer for wood chips. Slide-out drip tray. The stainless steel drip tray below the grill and cooktop burners collects grease and spills and slides out for easy cleaning. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. 100 HOLD 10 SEC. WHILE LIGHTING GRILL 250 • Built-in or portable • Natural or LP gas must be specified by model number • Stainless steel cart available • Insulated jacket required for combustible enclosure • Conversion kit available monogram.com 36" product dimensions Additional clearances ZGG36N31CSS 3 grill burners, 1 rotisserie burner (Order ZGG36L31CSS for LP gas) Observe all clearances shown. • Allow at least 12" clearance on each side to combustible vertical surfaces and at the rear when exhaust is directed to a window or a surface that is difficult to clean. advantium ® Speedcook wa ll oven Advance planning for 36" outdoor cooking centers • Allow at least 6" clearance on each side to any non-combustible material located above the cooking surface. Rotisserie models also require 6" clearance for placing and handling the motor and skewer. Installation in a non-combustible (masonry) enclosure The grill drops into the opening and hangs from its side flanges. A deck is not required for support. Install Electrical Outlet for Rotisserie On Right side (6.5 AMP Min.) 12" Min. to Combustibles 3" Clearance for Lid 34-1/2" 22-3/4" ZXADYSS stainless steel double access doors Optional accessory to cover the access opening under the grill in a built-in installation. ZX36CV3Y vinyl cover fits built-in 36" models with 3 grill burners. ZX36CTACSS 36" grill cart This cart has a fold-down shelf on each side. Inside is a shelf for utensils and condiment bins on the door. Behind the other door is a slide-out tray for easy access to the LP tank. warming drawer s Cutouts for built-in installations microwave ove n s Built-in accessories 35-1/2" Max. 18-1/2" HOLD 10 SEC. WHILE LIGHTING FRONT REAR IGNITOR 4x4 Opening for Gas Supply Line 9-1/8" Opening for Access Doors ROTISSERIE GRILL ROTESSERIE IGNITOR Slide-Out Tank Tray Accessory doors ZXADYSS cutout: 24-1/8"W x 18-1/4"H SMOKER GRILL IGNITOR SMOKER IGNITOR GRILL GRILL IGNITOR Grill cart dimensions: 36"W x 35-5/8"H x 25-1/4"D Shelf dimensions: 21"D x 16"W 23-3/4" 35-1/2" Max. 18-1/2" 10-1/8" 3-1/8" Opening for Access Doors Cart accessories ZX36CVCC vinyl cover fits all 36" models installed on a cart. Type of gas Monogram® outdoor cooking centers are factory set for either natural or liquid propane gas. The correct model must be ordered for the installation situation. Conversion kits (WB49X10084, natural to LP and WB49X10083, LP to natural) are available if the wrong gas type was ordered. The kits must be installed by a qualified service technician at additional cost. Dual -burn er out d oor c ookt op 12" Min. to Combustibles 3" Clearance for Lid 40-1/2" Install Electrical Outlet for Rotisserie On Right side (6.5 AMP Min.) 3 6" out doo r c ook ing cent e r s 605Dia191 Installation in a combustible enclosure ZX36JYSS insulated jacket is required The insulated jacket must be supported from the bottom by a solid deck or ledge on each side beneath the jacket. Construct the enclosure as shown and place the insulated jacket into the enclosure. Place the cooking center into the jacket. The serial plate is located in the back of the burner box, below the burner grates. 4x4 Opening for Gas Supply Line Accessory doors ZXADYSS cutout: 24-1/8"W x 18-1/4"H 605Dia192 101 Dual-burner outdoor cooktop General features Porcelain-coated cast-iron burners. The spark-ignition burners are 15,000-BTU-rated and come with a removable stainless steel cover that doubles as a work surface. Burners are baffled to reflect heat into the cooking area. REAR FRONT IGNITOR Precision brass valves. Controls are mounted on durable brass valves that resist rust and corrosion, ensuring long life in an outdoor environment. Dual-burner outdoor cooktop ZX2NYSS Drip pan. The full-width stainless steel pan slides out easily for removal and cleaning. ZX2LYSS (liquid propane) Versatile installation. The dual-burner cooktops are designed to be built in. The cooktop provides additional outdoor cooking area and complements the built-in 36” outdoor cooking center. For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com. ZX2NYSS (natural gas) Overall dimensions (WxHxD in inches): 13 x 10-1/2 x 25-3/4 Approx. shipping wt. (lbs.) 56 • For built-in installations • Natural or LP gas must be specified by model number • Trim kit required for enclosure • Insulated jacket required for combustible enclosure Advance planning for dual-burner outdoor cooktop Dual-burner outdoor cooktops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. These cooktop burners are designed for outdoor use only. • The burner is designed to be built into an enclosure. 2x2 Opening for Gas Supply Line 13-1/8" 23-5/8" 10-3/8" Product dimensions Installation in a combustible enclosure ZX2JYSS insulated jacket is required The insulated jacket must be 2x2 supported from the bottom by Opening a solid deck or ledge on each for Gas Supply side beneath the jacket. Line Construct the enclosure as 1" shown and place the insulated jacket into the enclosure. 605Dia208 ZX2NYSS Natural gas ZX2LYSS LP gas 10-1/2" 23-3/4" 25-3/4" 13" 15-3/8" 11" 24-5/8" 1-1/8" 2" Accessories Clearances 605Dia206 • When installed in an enclosure, allow 6" clearance at the rear and both sides to vertical combustible materials. • When installed into a combustible enclosure, the cooking surface should be 1" above adjacent horizontal surfaces and 35-1/2" above the floor. 102 Installation in a non-combustible (masonry) enclosure The burner drops into the opening. The burner must be supported by a solid deck. 605Dia209 ZX2TKYSS trim kit For combustible and non-combustible enclosures. The trim will conceal the gap at the rear and sides of the opening. The cooktop should be installed at least 35-1/2" above the floor. Dual -burn er out d oor c ookt op 3 6" out doo r c ook ing cent e r s warming drawer s microwave ove n s advantium ® Speedcook wa ll oven monogram.com Notes 103 Notes 104 monogram.com Notes 105 Notes 106 p e r s p e c t i v e s D e s i g n G u i d e A GE M O N O GR A M PU B L IC ATI O N As an ENERGY STAR® partner, GE has determined that the appliances marked with the ENERGY STAR logo meet the ENERGY STAR guidelines for energy efficiency. Before purchasing an ENERGY STAR qualified appliance, read important information about its estimated annual energy consumption or energy efficiency rating that is available from your retailer, monogram.com or www.energystar.gov. Product improvement is a continuing endeavor at GE. Therefore, materials, appearance and specifications are subject to change without notice. 2007 © 2007 GE Company Publication Number 24-M577 PC49881 perspectives monogram 2007 design guide