ICP-CC404 | Installation Guide | 16.0 Programmable Outputs Table 54: Option 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Event Type Polarities Description Output not used Normally open, going low Normally open, pulsing low Normally open, one-shot low Normally open, one-shot low (can restart timer) Normally open, one-shot low (can reset) Normally open, one-shot low (alarm) Normally open, latching low Normally low, going open Normally low, pulsing open Normally low, one-shot open Normally low, one-shot open (can restart timer) Normally low, one-shot open (can reset) Normally low, one-shot open (alarm) Normally low, latching open 0 – Output Not Used If an output is not required, program the polarity as 0. 1 – Normally Open, Going Low This polarity is a normally-open circuit and switches to 0 V when the event occurs. The output switches back to an open circuit when the event is restored. Time parameters do not apply to this polarity. 2 – Normally Open, Pulsing Low 5 – Normally Open, One-Shot Low with Reset This one-shot polarity is a normally-open circuit and switches to 0 V when the event occurs. Because the output switches back to an open circuit when the oneshot time expires or when the event returns to normal, the operation of the output can be shortened regardless of the programmed time parameter. 6 – Normally Open, One-Shot Low with Alarm This one-shot polarity is a normally-open circuit and switches to 0 V when the event occurs. The output switches back to an open circuit when the one-shot time expires, when the event returns to normal, or when the system is disarmed. This polarity is ideally suited for the operation of strobe lights because you can program the lights to reset (up to 99 hours) and prevent them from burning out or bothering others due to prolonged operation. 7 – Normally Open, Latching Low This polarity is a normally-open circuit and switches to 0 V when the event occurs. The output switches back to an open circuit when a user holds down [7] on the remote codepad until two beeps sound. Time parameters do not apply to this polarity. 8 – Normally Low, Going Open This polarity is normally 0 V and switches to an open circuit when the event occurs. The output switches back to 0 V when the event ends. Time parameters do not apply to this polarity. This polarity is a normally-open circuit and switches to pulsing 0 V when the event occurs. The output switches back to an open circuit when the event is restored. Time parameters vary the On time of the pulse. 9 – Normally Low, Pulsing Open 3 – Normally Open, One-Shot Low 10 – Normally Low, One-Shot Open This one-shot polarity is a normally-open circuit and switches to 0 V when the event occurs. The output switches back to an open circuit when the time parameter setting expires. This one-shot time setting always runs its full duration and cannot be manually reset. This one-shot polarity is normally 0 V and switches to an open circuit when the event occurs. The output switches back to 0 V when the time parameter expires. This one-shot time setting always runs its full duration and cannot be manually reset. 4 – Normally Open, One-Shot Low with Reactivate This one-shot polarity is normally 0 V and switches to an open circuit when the event occurs. Every time the event occurs, it restarts the one-shot timer. The output switches back to 0 V when the one-shot time expires. This one-shot polarity is a normally-open circuit and switches to 0 V when the event occurs. Every time the event occurs, it restarts the one-shot timer. The output switches back to an open circuit when the oneshot time expires. This polarity is ideally suited for lighting control. You can use a PIR to activate an output to turn on lights. Whenever there is movement, the PIR reactivates the output and lengthens the time the lights remain on. Bosch Security Systems, Inc. | 12/08 | F01U089401-02 This polarity is normally 0 V and switches to a pulsing open circuit when the event occurs. The output switches back to 0 V when the event ends. Time parameters vary the Off time of the pulse. 11 – Normally Low, One-Shot Open with Reactivate 12 – Normally Low, One-Shot Open with Reset This one-shot polarity is normally 0 V and switches to an open circuit when the event occurs. Because the output switches back to 0 V when the one-shot time expires or when the event returns to normal, the oneshot timer can be shortened regardless of the time setting. 69