Download cat eye ergociser

Transcript
T-6-2
No Cadence Control (Faster cadence control is not possible.) (2)
Check Method of Causes
Explanation Figures
Repair Method
[4] Checking the CDC Sensor
1. Replace the CDC sensor cable with a brandnew one.
Power Supply Board
CDC Sensor Set
A. Detach the CDC sensor cable from the CDC sensor set.
(Fig. 5)
B. Disconnect the 4P connector at the power supply board,
and disconnect the CDC sensor cable. (Fig. 6)
C. Connect the 4P connector of the new CDC sensor cable to
the connectors of both the CDC sensor set and the power
4P Connector
2. Connect the 5P cable to the power supply board, and check
the voltage. (Fig. 7)
CDC Sensor Cable
A. Turn on the power of the main unit.
Fig.6
Fig.5
B. Slowly move the pedal, while checking the voltage by using
5P Connector
a tester across Terminal 1 and Terminal 4 of the cable
connector (5P connector at the side of control unit
Nomal condition: Frequently shifting
between 0V & 5V
Power Supply Board
connection) of the 5P cable. (Fig. 8)
Red Cable
(Terminal 1)
Terminal 1 is for plus (+) and Terminal 4 is for minus (-).
Black Cable
(Terminal 4)
C. When the voltage frequently changes between approx. 5V
and 0V, the CDC sensor is all right.
[Judgment]
ⓦ When the voltage is found to be correct, the CDC sensor
cable has been disconnected. In this case, you need to
take actions in the repair method (e) described at the right.
(e) Replace the CDC sensor cable.
(See [ES-7: Replacing the CDC Sensor Cable].)
Cable Connector
Fig.7
Fig.8
T-6-2
When the voltage is not correct, proceed to the procedures on the
next page.
No Cadence Control (Faster cadence control is not possible.) (2)
supply board. (Figs. 5 and 6)
Cateye Ergociser EC-5000 Service Manual
21