Download Cypress Avalon Owner`s manual
Transcript
Installation (for qualified installers only) 16 Closing the Diffuser (for top vent configurations only) IMPORTANT NOTE: The diffuser can be easily closed with no vent in place. Consult the vent configuration charts to determine diffuser position. If the diffuser needs to be in the closed position, adjust the diffuser prior to installing vent. • To close the diffuser, reach into the vent starter section and bend the diffuser back (see photos below). You may need a screwdriver to bend the upper portion of the diffuser 90° (see photos below). Diffuser Open (stock) Diffuser Closed Closing the Diffuser After Vent is Installed • The diffuser may be removed from within the firebox and bent into the closed position . This requires removal of the burner, fireback shelf, and rear firebox wall (rivet cover). Once removed, the diffuser may be removed from below, bent 90°, and re-installed. See the illustration below. b Bend the round portion of the diffuser so it is bent (position # 2). The diffuser is found on the inner flue assembly . DIFFUSER SIDE VIEW Bottom of inner Inner flue assembly Before (Stock - Position # 1) flue assembly a Remove the diffuser. © Travis Industries 4101110 c After (Position # 2) Replace the diffuser. 100-01256_000