Download Dean D60 Series Programming instructions
Transcript
DECATHLON SERIES GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers 1. Disconnect the fryer from the electrical supply. 2. Drain cooking oil from the frypot. Allow the frypot to cool completely before proceeding. 3. Remove the fryer door for easier access to the temperature probe. D models: Lift door up, disengage rod from lower door bracket, and remove door. CFD/SCFD/FPD models: Remove the top bracket and hinge, then remove door. 4. Disconnect the probe harness connector (arrow). Use a pin pusher to remove plug from probe wires (probe side only). Retain the plug for re-assembly on new probe. 5. a. 1.5” drains: Remove drain extension from elbow on drain valve. Set aside for reassembly. Drain extensions will vary in shape and size according to fryer model. b. 3” drains: - Remove the nuts holding the drain valve straps onto the drain tube studs. - Disconnect the Teflon tube at the back of the T-shaped center tube piece. - Disconnect any other attached to the tubes. - Carefully remove the tubes by pulling down at an angle, straight out of the drain valves. - Set aside for reassembly. Disconnect the two-pin probe harness connector (arrow). On units with 1.5” drains, remove the drain extension from the elbow on the drain valve. components NOTE: Dean fryers may be equipped with either 1.5” or 3” drains. Follow the instructions appropriate for the drain type used. On units with 3” drains, remove the nuts, Teflon tube (not pictured), clamp, boot, and drain tubes. (Step 5.B) 1-15