Download Alliance Laundry Systems 1336 Specifications
Transcript
PowerFlex 40 and 400 Drive Control Logic Pocket Hardmount WE-6 control - Design 6, 7 and 8 0 = No signal received 1 = Signal received H – Signal Voltage High (approximately 24V DC) L – Signal Voltage Low (less than 1V DC) Fwd DC Volt Meter Red Probe Terminal Location 07 06 05 01 03 02 DC Volt Meter Black Probe Terminal Location 04 04 04 04 04 04 Terminal #07 (SW3) Terminal #06 (SW2) Terminal #05 (SW1) Terminal #01 (Stop) Terminal #03 (STR) Terminal #02 (STF) Action Frequency Preset Parameter # Digital Input Control Input Status – Parameter Status – Parameter d014 d013 Fwd (STF) Rev Rev (STR) Stop Stop Digital In 1 Digital In 3 (SW3) Digital In 2 (SW2) Digital In 1 (SW1) DB Trans On Digital In 2 *Digital In 4 Digital In 3 Idle N/A H H H L/H H H 0 0 0 0 0 0/1 0 0 1/2 Wash Speed Forward 70 H H H L H L *1 0 0 0 0 1 0 1 1/2 Wash Speed Reverse 70 H H H L L H 0 0 0 0 0 1 1 0 Wash Speed Forward 72 H L H L H L *1 0 1 0 0 1 0 1 Wash Speed Reverse 72 H L H L L H 0 0 1 0 0 1 1 0 Distribution Speed 71 H H L L H L *1 0 0 1 0 1 0 1 Medium Extract/Spray Rinse 76 L L H L H L *1 1 1 0 0 1 0 1 Extract Speed 1 75 L H L L H L *1 1 0 1 0 1 0 1 1 Extract Speed 2 73 H L L L H L *1 0 1 1 0 1 0 Extract Speed 3 (default) 77 L L L L H L *1 1 1 1 0 1 0 1 Extract Speed 3 (maximum) 74 L L H L H L *1 1 0 0 0 1 0 1 *If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise. Table 11 F232120R7 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 17