Access using the Address in ACCU 1
It changes if one of the following occurs:
• another data block is opened
or
• the program returns to a higher level block after a new data block
was opened in the inserted block (see also Section 2.4.2, Range of
Validity of Data Blocks).
Note
In the ISTACK, the address entered in the DBA register appears
under the heading "DB-ADD".
You normally access data words with the STEP 5 operations L/T DW,
L/T DR, L/T DL, L/T DD, A/O/AN/ON/=/S/R Dx.y. You can only
use these operations up to data word DW 255. However, by
manipulating the DBA register, you can use them to access data
words > 255. This is also possible with special function OB 180 (see
Section 6.15).
Examples
Example 1: Effect of the "CX DX 17" operation on the DBA register:
Addresses
DX 17
1516H
1517H
1518H
5 words
block header
1519H
151AH
DBA
151BH
KH = 0000
DW 0
151CH
KH = 0001
DW 1
151DH
Fig. 9-5
.
.
.
DW 2
Using the DBA register
When DX 17 is called, the address of the memory word in which DW 0 is
stored is entered in the DBA register. In this example, the DBA is
4152H.
Note:
In the ISTACK, the address entered in the DBA register appears
under the heading ’DB-ADD’.