Download Dayton 4E769B Operating instructions

Transcript
Dayton Operating Instructions and Parts Manual
Model 4E769B
General Safety Information
• The electrical connections and
grounding of the heater shall follow
the National Electric Code, ANSI/
NFPA 70.
• Electrical grounding instructions —
This appliance is equipped with a
three-prong (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle.
• Use only the electrical voltage and
frequency specified on model plate.
• Use only a three-prong, grounded
extension cord.
(Continued)
Specifications
ELECTRICAL SPECIFICATIONS
Electrical
Input
Amperage
120 Volt/60Hertz
2
GENERAL SPECIFICATIONS
Output
Rating BTU/Hr
Fuel
35,000
Only Propane Vapor
Fuel
Consumption
Size
L x W x H (Inches)
Regulator
Outlet Pressure
Weight
(pounds)
.38 Gallons/Hour
1.6 Pounds/Hour
18.5 x 7.7 x 12.8
11" WC
14.5 (Heater)
16 (Shipping)
GENERAL SPECIFICATIONS (Cont.)
Manifold
Pressure
Hot Air Output
(CFM Approx)
10.8" WC
175
Ignition
Manual
Piezo
Supply Pressure
To Regulator
Temperature Range
For Operating Heater
10 psi Minimum (for)
-20° F to 85° F*
purposes of input
adjustment) Tank Pressure
or 200 psi Maximum
Motor
2735 RPM
(*) When running heater in temperatures above 85° F, high internal temperatures may cause thermal limit device to shut down
heater.Minimum ambient operating temperature: -20°F (-28°C).
®
3
Version B - For Reduction
G016.J