Download Axis A1001 Installation guide
Transcript
AXIS A1001 Network Door Controller Power & Relay Connector 6-pin terminal block with built-in relay for: Notes ENGLISH • External devices • Auxiliary power (DC output) • 0 V DC (-) Connect locks and loads to the pins according to the hardware pin chart generated through the hardware configuration. Function Pin 0 V DC (-) 1, 4 Relay 2–3 For connecting relay devices. Use the hardware pin chart. See Configure the Hardware, on page 23. The two relay pins are galvanically separated from the rest of the circuitry. Max current = 700 mA Max voltage =+30 V DC 12 V DC 5 For powering auxiliary equipment. Note: This pin can only be used as power out. Max voltage = +12 V DC Max load = 500 mA Specifications 0 V DC Tampering Alarm Pin Header Two 2-pin headers for bypassing: • Back tampering alarm (TB) • Front tampering alarm (TF) Function Pin Notes Back tampering alarm 1–2 Front tampering alarm 1–2 To bypass the front and back tampering alarm simultaneously, connect jumpers between TB 1, TB 2 and TF 1, TF 2 respectively. Connection Diagrams Connect devices according to the hardware pin chart generated through the hardware configuration. For more information about hardware configuration and the hardware pin chart, see Configure the Hardware, on page 23. 21