Direct Vent Gas Fireplace Installation and Operating Instructions Model: 6000dv WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. –WHAT TO DO IF YOU SMELL GAS •Do not try to light any appliance. •Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. – Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: Improper installation, adjustment, alteration, services or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. This appliance may be installed in an aftermarket*, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. 420200 DUE TO6000DV H I G H cover TE M PERATURES , THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. Keep the room area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 42D0200 8/09 Rev. 12 6000DV Gas Fireplace Important Safety Information.......................................3 Product Features...........................................................5 Code Approval...............................................................5 Pre-Installation Information High Elevations.........................................................6 Orifice Sizes, Pressures and BTUs...........................6 Before You Install......................................................6 Fireplace Dimensions...............................................7 Fireplace Framing ........................................................8 Framing Peninsula Fireplace....................................8 Framing Corner Fireplace.........................................8 Framing See Through Fireplace...............................9 Fireplace Location...................................................10 Secure Fireplace to Floor or Framing.......................12 Clearances...................................................................13 Vent Installation...........................................................14 Installation Precautions...........................................14 Optional Top Vent Application.................................16 Installation Planning................................................17 Installation for Vertical Termination.........................17 Horizontal Termination............................................18 How to Use the Vent Graph....................................19 Rear Wall Vent Installation......................................20 Horizontal Termination Configuration......................22 Below Grade Installation.........................................24 Vertical Through-the-Roof Installation.....................25 Installation for Vertical Termination.........................26 Flat Ceiling Installation............................................26 CONTENTS Fireplace Installation...................................................28 Check Gas Type.....................................................28 Installing Gas Piping to Fireplace/Burner System Location..................................................................28 Checking Gas Pressure..............................................30 Electrical Installation..................................................30 Electrical Wiring......................................................30 Remote Wall Switch................................................31 Electronic Pilot Ignition..............................................32 Remote Wall Switch................................................32 Glass Removal.............................................................33 Log Placement.............................................................34 Air Restrictor Adjustment...........................................37 Operating Instructions................................................38 What To Do If You Smell Gas..................................38 Lighting Pilot for the First Time...............................38 Lighting Pilot...........................................................39 Lighting Burner........................................................40 To Turn Off Gas.......................................................40 Cleaning and Maintenance.........................................41 Venting System.......................................................41 Cleaning Glass........................................................41 Pilot and Burner Flames.........................................41 Firebox Cleaning.....................................................41 Troubleshooting..........................................................42 Blower..........................................................................44 Replacement Parts......................................................45 Massachusetts Residents Only.................................50 Warranty.......................................................................51 Efficiencies..................................................................52 42D0200 IMPORTANT SAFETY INFORMATION 6000DV Gas Fireplace OWNER Please leave these instructions with the owner. Please retain these instructions for future reference. WARNING INSTALLER • Read this owner’s manual carefully and completely before trying to assemble, operate, • • or service this fireplace. Any change to this fireplace or its controls can be dangerous. Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning. This fireplace is a vented product. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, combustion leakage can occur. CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have the fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 gal. capacity. 3. If you smell gas • shut off gas supply. • do not try to light any appliance. • do not touch any electrical switch; do not use any phone in your building . • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 42D0200 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. 7. Do not modify fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace. 8. Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair the fireplace. Have burner system inspected annually by a qualified service person. 9. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, pet hair, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. Refer to Cleaning and Maintenance, page 41. 11. Keep the area around your fireplace clear of combustible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. IMPORTANT SAFETY INFORMATION and code approval 14. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. 16. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation. 17. When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, you must set appliance on a metal or wood panel or hearth pad extending the full width and depth of the appliance. 18. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 19. Do not operate fireplace if any log is broken. 20. Do not use a blower insert, heat exchanger insert, or any other accessory not approved for use with this fireplace. 21. Do not operate the fireplace with glass door removed, cracked, or broken. 22. This unit is approved for bedrooms and bathrooms. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplaces to give off some odor the first time it is burned. This is due to the manufacturing process. Please ensure that your room is well ventilated during burn off — open all windows. It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. Place the fan switch in the “OFF” position during this time. WARNING 6000DV Gas Fireplace Never connect unit to private (nonutility) gas wells. This gas is commonly known as wellhead gas. 42D0200 product features and code approval 6000DV Gas Fireplace product SPECIFICATIONS • This appliance has been certified for use with • • • • • • • either natural or propane gas. See appropriate data plates. This appliance is not for use with solid fuels. The appliance is approved for bedroom or bedsitting room installations. The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada. This appliance is mobile home approved. This appliance is approved for bathroom installation. The appliance must be properly connected to a venting system. The appliance is not approved for closet or recessed installations. Optional Remote Receiver The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system. Hi/Lo Knob Off/Pilot/On Knob FP2276 Blower Control Control Panel Figure 1 6000DV Fireplace Controls FP2276 6000DV prod features Code Approval Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe. These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows: Listed Vented Gas Fireplace Heater Tested To: ANSI Z21.88b-2008 / CSA 2.33b-2008 Standards A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4. 42D0200 6000DV Gas Fireplace pRE-INSTALLATION INFORMATION HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level. For elevations above 4,500 feet (1,370 m) in USA, installation must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. In Canada, please consult provincial and/or local authorities having jurisdiction for installation at elevations above 4,500 feet (1,370 m). ORIFICE SIZES, PRESSURES AND BTUs Natural GasPropane Gas Manifold Press: (w.c.) 3.5" Manifold Press: (w.c.) Maximum Supply Pressure 10.5" Maximum Supply Pressure Minimum Supply Pressure 4.5" Minimum Supply Pressure 10" 13" 11" Model Number 6000DV NaturalPropane Max. BTU/hr Input 36,000 36,000 Min. BTU/hr Input 25,000 26,000 Orifice size (as shipped) #44 #54 Before You install Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following: • Fireplace (Firebox and Burner System) • Log Set • Lava Rock • Rock Wool • Deflector Shield (to be used with Simpson DuraVent Horizontal Termination – P/N 985) Items Required For Installation Tools: Building Supplies: • Phillips Screwdriver • Framing Materials • Hammer • Wall Finishing Materials • Saw and/or saber saw • Caulking Material (Noncombustible) • Level • Fireplace Surround Material (Noncombustible) • Measuring Tape • Piping Complying with Local Codes • Electric Drill and Bits • Tee Joint • Pliers • Pipe Sealant Approved for use with Propane/LPG • Square (Resistant to Sulfur Compounds) • Pipe Wrench 42D0200 FIREPLACE DIMENSIONS 6000DV Gas Fireplace 2(6QE” See-Through and Peninsula Model Dimensions 236M” 18(6” 4(6QE” 396” C L 4056QE” 5/8” 1/2” 3456O” 326M” 1/2” 5/8” Gas/Electric Access 44” 356M” 420200 6000Dv penin dims 18(6” Corner Model Dimensions (Right shown) 2456O” 4(6QE” 396” 5/8” 1/2” 376M” 16M” 1956O” 3256M” 376M” 4056QE” 1/2” 5/8” Figure 2 Fireplace Dimensions 42D0200 44” 420200 6000DV corner dims Gas/Electric Access FIREPLACE Framing 6000DV Gas Fireplace It is best to build firebox framing after the appliance is set in place. Refer to the dimensions for your fireplace on Page 7. The framing headers may rest on the top of the firebox standoffs. The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. Do not place firebox on carpeting, vinyl, or other soft floor coverings. It may, however, be placed on a flat wood, plywood, particle board, or other hard surfaces. Be sure firebox rests on a solid continuous floor or platform with appropriate framing for support. No cold air should enter room from under the firebox. Peninsula Framing Gas Connection 2 x 4 (Minimum) A1 A2 C FP2038 B C A Top View A 1 2 Figure 3 Peninsula Framing Corner Framing Top View Gas Connection A1 A2 2x4 (Minimum) 2x2 (Minimum) FP2037 FP2038 2x4 B (Minimum) designer see thru framing C 10/08 A1 A2 Peninsula & Corner Framing Specifications 1/2" Drywall 5/8" Drywall Figure 4 A1 43Z\x" 43C\," Corner Unit Framing A2 39M\," 39C\v" (Right Hand Configuration shown) B 41Z\," 41Z\," C 22C\v" 22Z\x" D 24" 23M\," D 42D0200 framing FIREPLACE 6000DV Gas Fireplace Framing See Through Fireplace * Note: For ease of installation, frame around the firebox after it has been set. Refer to chart below for specifications. When installing into existing framed (A1) openings, loosen the junction box. Remove the rear-mounted flue pipe adaptor. Refer to Page 16, Figures 10 and 11. Reattach both assemblies. See-through Framing Gas Connection A1 2x4 (Minimum) 2x4 (Minimum) A2 FP2038 B C A Top View WARNING See-through Framing Specifications 1/2" Drywall 5/8" Drywall A1 44Z\v" 44Z\v" A2 40B\," 40B\," B 41Z\," 41Z\," C 22C\v" 22Z\x" A 1 2 C Figure 5 See-Through Framing The fireplace must be installed giving full FP2038 consideration to the clearance and height designer see thru framing requirements identified10/08 in this manual. 42D0200 pRE-INSTALLATION INFORMATION 6000DV Gas Fireplace INSTALLATION AND OPERATING INSTRUCTIONS This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CSA-B149 (.1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. If the unit is being installed in a mobile home the installation should comply with the current CAN/ CSA Z 240 .4 code. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1. fireplace location For Safe Installation and Operation Please Note The Following: 1. This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of the high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing. 3. Caution, due to high glass surface temperature children should be carefully supervised when they are in the same room as the fireplace. 4. Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating the fireplace again. 5. Installation and any repairs to this fireplace should be carried out by a qualified service person. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this fireplace. 7. The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned. 8. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung on or around the fireplace. 9. Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace. 10. The flow of combustion and ventilation air must not be obstructed in any way. 10 11. When the fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace. 12. This fireplace requires adequate ventilation and combustion air to operate properly. 13. This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace. 14. When the fireplace is not in use it is recommended that the gas control valve be left in the “OFF” position. This appliance has been approved for after-market mobile home installations. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace ON. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your Monessen gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process. Please ensure that your room is well ventilated — open all windows. It is recommended that you burn your Monessen fireplace for a least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “OFF” position during this time. 42D0200 pRE-INSTALLATION INFORMATION 6000DV Gas Fireplace X X X B A Y Z A A Flat on Wall B Room Divider Y Y FP2277 Figure 6 Possible Fireplace Locations A.WALL LOCATION Y Minimum distance between a glass panel andFP2277 a parallel wall = 42" locate fireplace Z Minimum distance between the edge of a glass panel and an adjacent wall = 3" B. Island Location X (Maximum length of horizontal venting = 20'. Refer to the venting section of this manual for specific dimensions. 42D0200 11 SECURE FIREPLACE to floor 6000DV Gas Fireplace SecurE fireplace to floor The fireplace must be secured to the floor and/or to framing studs as shown in Figure 7. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets are adjustable from 1/2" to 5/8" to accommodate different thickness of noncombustible material. Screws FP2278 Figure 7 Secure Fireplace to Floor and Framing Studs FP2278 secure fireplace 12 42D0200 clearances 6000DV Gas Fireplace WARNING Clearances to combustibles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance. Wall 10” mantel clearances 8” NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual. Insulation Board 6” 12” 4” 10” 2” 8” Standoff 6” 4” Top of Louvers WARNING Figure 8 Mantel Clearances Never obstruct or modify the air inlet or outlet grills may create a fire hazard. FP2279 FP2279 mantel clearance 2/09 (louvers). This Finishing Material NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction. Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to cover the black-painted face of the appliance. A 300°F minimum adhesive may be used to attach facing materials to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or equivalent) must be used. Combustibles may come to the top and side edges but not overlay the face. 42D0200 13 VENT INSTALLATION 6000DV Gas Fireplace Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. NOTICE WARNING Vent installation Failure to follow these instructions will void the warranty. installation precautions NOTE: This appliance must be installed with a Monessen approved venting system only. Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions. Only a qualified installer/service person should install venting system. The installer must follow these safety rules: • Wear gloves and safety glasses for protection. • Use extreme caution when using ladders or when on rooftops. • Be aware of electrical wiring locations in walls and ceilings. The following actions will void the warranty on your venting system: • Installation of any damaged venting component. • Unauthorized modification of the venting system. • Installation of any component part not manufactured or approved by MHSC. • Installation other than permitted by these instructions. 14 42D0200 6000DV Gas Fireplace Horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1" clearance all around the flue is acceptable at this point of penetration. WARNING WARNING Vent installation This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems. Vertical sections of this vent system require a minimum of 1" clearance to combustibles on all sides of the pipe. A Minimum of 3" Clearance to the Top Is Required Along Horizontal Length until Flue Pipe Penetrates Outside Wall. 1" 3" 1" 1" A Minimum 1" Clearance to Combustibles Permitted All Around Flue at Outside Wall FP2280 Figure 9 Combustible Clearances for Vent Pipe 42D0200 FP2280 vent pipe clear 15 vent installation 6000DV Gas Fireplace WARNING Optional top vent application The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration the appliance can be converted by following the steps below. When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required. 1. Remove the eight (8) screws securing the flue pipe adapter to the fireplace body. Figure 10 2. Set the flue pipe adapter aside, complete with the gasket. Do not damage the gaskets as the adapter and gasket must be refitted. 3. Remove the eight (8) screws securing the flue pipe cover to the top of the intake box and remove the cover and gasket. Figure 10 4. Remove eight (8) screws securing the flue pipe to the back of the intake box and remove the pipe and gasket. Figure 11 5. Replace flue pipe to top of firebox. Ensure the gasket is in place and undamaged. Secure with eight (8) screws. Figure 12 6. Place the flue pipe cover and gasket removed in step 3 over the flue opening in bottom of the intake box. 7. Refit the flue pipe adapter and gasket to the top of fireplace. Secure the adapter with eight (8) screws removed in step 1. After conversion to top vent configuration the 4" (102 mm) flue pipe should be concentric within the 6B\," (175 mm) outer collar (within 1/4"). Screws Flue Pipe Adapter Flue Pipe Adapter FP1991 Figure 10 Remove 16 Screws from Flue Pipe Adapter and Flue Pipe Cover Flue Pipe Cover Screws Flue Pipe Screws FP1991 remove screws Flue Pipe Figure 11 Remove Flue Pipe FP1992 Figure 12 Attach Flue Pipe to Top Vent Colnfiguration FP1993 42D0200 16 FP1992 remove flue pipe FP1993 6000DV Gas Fireplace installation planning There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness. WARNING Vent installation Never run the vent pipe down. This may cause excessive temperatures which could cause a fire. for horizontal termination Select the amount of vertical rise desired. All horizontal run of venting must have 1/4" rise for every 12" of run towards the termination. You may use up to three 90° elbows in this vent configuration. Refer to Horizontal Termination Configurations on Pages 22 and 23. For vertical termination Measure the distance from the fireplace floor to the ceiling. Add the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roof line. NOTE: You may use two 45° elbows in place of a 90° elbow. You must follow rise to run ratios when using 45° elbows. The appliance is approved for use with three 90° elbows maximum or a combination of 90° and 45° elbows up to a maximum of 270°. For two-story applications, firestops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required. You may use a chase with a vent termination with exposed pipe on the exterior of the house. Refer to Installing Vent System in a Chase below. If pipe is enclosed in chase, it is not exposed. It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed. Installing a vent system in an outside chase Always maintain minimum clearances around vent systems. The minimum clearances to combustibles for horizontal vent pipe are 3" at the top and 1" at the sides and bottom of the vent system until the pipe penetrates the nearest vertical wall. A 1" minimum clearance all around the pipe must be maintained. Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may present a fire hazard. 42D0200 NOTICE WARNING Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must follow all local building codes. WARNING A chase is a vertical boxlike structure built to enclose venting that runs along the outside of a building. A chase is required for such venting. When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Insulation should be considered a combustible material. Maintain proper clearances to all combustible materials. 17 vent installation 6000DV Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A D L V E C V B F Figure 8 Termination Locations B Fixed Closed Ope rable V B V B B V VENT TERMINATION B V J A CFM145a V Fixed Closed Operable X AIR SUPPLY INLET X M I V K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1US Installations2 CFM145a DV Termin Location A = Clearance above grade, veranda, porch, 12” (30 cm) 12” (30 cm) 5/01/01 Rev. 12/05/01 deck, or balcony sta B = Clearance to window or door that may be 6” (15 cm) for appliances 6” (15 cm) for appliances opened < 10,000BTU/h (3kW), 12” (30 cm) < 10,000 BTU/h (3kW), 9” for appliances > 10,000 Btuh (3kW) and (23 cm) for appliances > 10,000 < 100,000 BTU/h (30kW), 36” (91 cm) Btuh (3kW) and < 50,000 BTU/h for appliances > 100,000 BTU/h (30kW) (15kW), 12” (30 cm) for appliances > 50,000 BTU/h(15kW) C = Clearance to permanently closed window 12” (305 mm) recommended to 12” (305 mm) recommended to prevent window condensation prevent window condensation D = Vertical clearance to ventilated soffit located above the terminal within a horizontal 18” (458 mm) 18” (458 mm) distance of 2’ (610mm) from the center line of the terminal E = Clearance to unventilated soffit 12” (305 mm) 12” (305 mm) F = Clearance to outside corner see next page see next page G =Clearance to inside corner (see next page) see next page see next page H = Clearance to each inside of center line 3’ (91 cm) within a height of 15’ (5 m) 3’ (91 cm) within a height of 15’ extended above meter/regulator assembly above the meter/regulator assembly (5 m) above the meter/regulator assy I = Clearance to service regulator vent outlet 3’ (91 cm) 3’ (91 cm) J = Clearance to nonmechanical air supply inlet 6” (15 cm) for appliances < 10,000 6” (15 cm) for appliances to building or the combustion air inlet to any BTU/h (3kW), 12” (30 cm) for < 10,000 BTU/h (3kW), 9” other appliances appliances > 10,000 BTU/h (3kW) and (23 cm) for appliances > 10,000 < 100,000 Btuh (30kW), 36” (91 cm) BTU/h (3kW) and < 50,000 BTU/h for appliances > 100,000 BTU/h (30kW) (15kW), 12” (30 cm) for appliances > 50,000 BTU/h(15kW) K = Clearance to a mechanical air supply inlet 6’ (1.83 m) 3’ (91 cm) above if within 10' (3 m) horizontally L = Clearance above paved sidewalk or paved 7’ (2.13 m)† 7’ (2.13 m)† driveway located on public property M =Clearance under veranda, porch, deck or 12” (30 cm) 12” (30cm) balcony 1 In accordance with the current CSA-B149 Installation Codes 2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: 18 NOTE: 1. Local codes or regulations may require different clearances. 2. The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency. 3. MHSC assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. 42D0200 vent installation 6000DV Gas Fireplace termination clearances for buildings with combustible and noncombustible exteriors D C C G G=6" (152mm) V V V Inside Corner E F=6" (152mm) F Outside Corner C = Maximum depth of 48" (1219mm) for alcove location D = Minimum width for back wall of alcove location Combustible - 38" (965mm) Noncombustible - 24" (610mm) E = Clearance from corner in alcove location Combustible - 6" (152mm) Noncombustible - 2" (51mm) H G V V G = Combustible 24"(610mm) Noncombustible 18"(457mm) J Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm) Balcony with No Side Wall Figure 13 Allowable Venting Chart Balcony with Perpendicular Side Wall The Vent Graph should be read in conjunction with the following vent installation instructions to determine the relationship between the vertical and horizontal dimensionsFP1951 of the vent system. 1. Determine the height of the center oftermination the horizontalclearances vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph below, locate the point intersecting with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the fireplace in accordance with same. Example: If the vertical dimension from the floor of the fireplace is 11' (3.4 m) the horizontal run to the face of the outer wall must not exceed 14' (4.3 m). Example: If the vertical dimension from the floor of the unit is 7’ (2.14m), the horizontal run to the face of the outer wall must not exceed 8Z\x' (2.6 m). Sidewall Vent Graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system. Dimensions in Feet eg: A 2 4 6 8 10 12 14 16 18 20 Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pipe How To Use The Vent Graph Alcove Location 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 20" 4 2 Horizontal Dimension From the Outside Face of the Wall to the Center of the Fireplace Vent Flange Figure 14 Rear Wall Venting Graph 42D0200 FP2248 sidewall vent graph 19 Venting installation 6000DV Gas Fireplace Rear Wall Vent installation When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • The maximum horizontal distance between the rear of the appliance and the outside face of the rear wall is 20" (508 m). Figure 15 • Only one 45° elbow is allowed in these installations. 9Z\x" (241 mm) 20" (508 mm) Top View Flat Installation 11Z\x" (292 mm) Figure 15 Rear Vent Application, Maximum Horizontal Distance 1. Locate andDVR584-600 cut the vent opening in the wall. For combustibleRear wallsvent first frame in opening. no elbows Combustible Walls: Cut a 11Z\x"H x 9Z\x" W (292 x 2/99 djt 241 mm) hole through the exterior wall and frame as shown. Figure 16 Noncombustible Walls: Hole opening should be 7Z\x" (190 mm) in diameter. 2. Rigid vent pipes and fittings have special twist-lock connections. Assemble the desired combination of pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor. Twist-lock Procedure: The female ends of the pipes and fittings have three locking lugs (indentations). These lugs will slide straight into matching slots on the male end of adjacent pipes and fittings. Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. Figure 17 3. Attach vent pipe assembly to the fireplace. Set fireplace in front of its permanent location to insure minimum clearances. Mark the wall for a 11Z\x"H x 9Z\x"W (292 x 241 mm) rectangle hole (for noncombustible material such as masonry block or concrete, a 7Z\x" [190 mm] diameter hole is acceptable). Figure 16. The center of the hole should line up with the center line of the horizontal rigid vent pipe end. Be sure to allow for minimum rise. Cut a 11Z\x"x9Z\x" rectangle hole through combustible exterior wall (7Z\x" diameter hole if noncombustible). Frame as necessary. Allow 1/4" minimum rise per foot. Figure 16 7Z\x" (190 mm) FP1954 Figure 16 Vent Opening Requirements FP1954 wall framing Female Locking Lugs Note: Horizontal runs of vent must be supported every three (3) feet (914 mm). Use wall straps for this purpose. Male Slots FP1953 Figure 17 Rigid Vent Pipe Connections FP1953 rigid pipe 20 42D0200 vent installation 6000DV Gas Fireplace Rear Wall Vent installation (continued) Cut Vinyl Siding Away to Fit Standoff WARNING 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “UP” on the vent cap facing up. Insure proper clearance of 1" to combustibles is maintained. Attach the vent cap with four wood screws supplied. Figure 18 NOTE: Replace the wood screws with appropriate fasteners for stucco, brick, concrete, or other types of siding. For vinyl siding, stucco, or wood exterior use vinyl siding standoffs between vent cap and exterior wall. The vinyl siding standoff prevents excessive heat from melting the vinyl siding material. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of the standoff instead of the vent cap assembly. Use wood screws provided to attach the standoff. Figure 19 5. Slide fire stop over the vent pipe before connecting horizontal run to vent cap. Figure 20 6. Insert vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1Z\v". Fasten all vent connections with screws provided. 7. Slide fire stop against the interior wall surface and attach with screws. Figure 20 Deflecting Shield Vent Cap T HO FP1955 Apply Mastic to All Four Sides Wood Screw Figure 18 Installing Horizontal Vent Cap Do not recess vent termination into any wall. FP1955 This will cause a fire hazard. horizontal vent cap Deflecting Shield Standoff Interior Wall Surface Vent Cap Apply Mastic to All Four Sides Vent Cap (Horizontal Termination) T HO FP1956 Nut Bolt Wood Screw Figure 19 Installing Vinyl Siding Standoff FP1957 Screw FP1956 vinyl siding standoff 42D0200 Horizontal Vent Pipe Figure 20 Connecting Vent Cap with Horizontal Vent Pipe FP1957 install firestop 21 vent installation 6000DV Gas Fireplace Horizontal termination configurations 40 Since it is very important that the venting system maintain its bal- 38 ance between the combustion air intake and the flue gas exhaust, 36 certain limitations as to vent configurations apply and must be strictly 34 adhered to. 32 The Vent Graph, showing the relationship between vertical and horizontal 30 side wall venting, will help to determine the various dimensions allowable. 28 Figure 21 26 Minimum clearance between vent pipes and combustible materials is 24 3" on top and 1" from bottom and sides unless otherwise noted. 22 When vent termination exits through foundations less than 20" below siding 20 outcrop, the vent pipe must flush up with the siding. 18 It is best to locate the fireplace in such a way that minimizes the number 16 of offsets and horizontal vent length. 14 The horizontal vent run refers to the total length of vent pipe from the 12 flue collar of the fireplace (or the top of he Transition Elbow) to the 10 face of the outer wall. 8 6 • The maximum number of 90° elbows per side wall installation is three (3). Figure 22 20" 4 2 • If a 90° elbow is fitted directly on top of the fireplace flange the maximum horizontal vent run before the termination or a vertical rise is 36” (914 mm). Figure 23 Dimensions in Feet eg: A 2 4 6 8 10 12 14 16 18 20 Horizontal Dimension From the Outside Face of the Wall to the Center of the Fireplace Vent Flange Figure 21 Rear Wall Venting Graph 3 x 90° Elbows FP2248 sidewall vent graph 36" (914 mm) Max. 3 x 90° Elbows 36" (914 mm) Max. FP1176 Figure 22 Maximum Three (3) 90° Elbows Per Installation Figure 23 Maximum Horizontal Run with No Rise FP1177 FP1176 max 90 bends Max 20" 22 42D0200 vent installation 6000DV Gas Fireplace horizontal termination configuration (Continued) • If a 90° elbow is used in the horizontal vent run, the horizontal 90° vent length is reduced by 36" (914 mm). Figure 24. This does not apply if the 90° elbows are used to increase or redirect a vertical rise. Figure 24 A B Example: According to the vent graph, Figure 21, the maximum horizontal vent length in a system with a 7.5' vertical rise is 20’ (6 m) and if a 90° elbow is required in the horizontal vent it must be reduced to 17' (5.2 m). Refer to Page 19 “How to Use Vent Graph.” In Figures 25 and 26, Dimension A plus B must not be greater than 17' (5.2 m). • The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. • For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18" (45 cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system. • The maximum number of elbow degrees in a system is 270°. Figure 26 7’6” FP2305 Figure 24 Horizontal Run Reduction B 7’ A 10’ FP2305 run reduction 90° Elbow = 3' 1 A + B = 17' Maximum 2 7’6” Example: Elbow 1 Elbow 2 Elbow 3 Elbow 4 Total Angular Variation = = = = = 90° 45° 45° 90° 270° 3 4 1 2 3 4 FP2306 Figure 25 Maximum Vent Run with Elbows 1 + 2 + 3 + 4 = 270° FP2306 max vent run elbows Figure 26 Maximum Elbow Usage FP2307 FP2307 42D0200 max elbows 23 vent installation 6000DV Gas Fireplace Below Grade Installations When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178 mm) below grade level. The 7" (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall. Ensure that sidewall venting clearances are observed. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termination area. If installing a snorkel, a minimum 24" vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36". This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. Refer to the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24". WARNING 1. Establish vent hole through the wall. Refer to Page 20, Figure 16 2. Remove soil to a depth of approximately 16" below base of snorkel. Install drain pipe. Install window well (not supplied). Refill hole with 12" of coarse gravel leaving a clearance of approximately 4" below snorkel. Figure 27 3. Install vent system. •Do not back fill around snorkel. 4. Ensure a watertight seal is made around the vent pipe • A clearance of at least 4” must be maintained coming through the wall. between the snorkel and the soil. 5. Slide the snorkel into the vent pipes and secure to the wall. 6. Level the soil so as to maintain a 4" clearance below snorkel. Figure 27 If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2" sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. Figure 28 Screws Firestop Snorkel Minimum 4" Clearance Ground Foundation Recess Wall Screws Window Well 24" Minimum Gravel Drain Watertight Seal Around Pipe Sheet Metal Screws Foundation Wall FP1966 FP1965 Figure 27 FP1965 Below Grade Installation Figure 28 Snorkel Installation, Recessed Foundation FP1966 snorkel below grade install 24 42D0200 vent installation 6000DV Gas Fireplace vertical through-the-roof applications This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. Figure 29 10' Maximum 40' Maximum Height 8' Minimum Height 10' Maximum 40' Maximum Height 8' Minimum Height Support Straps Every 3' Support Straps Every 3' FP2308 Figure 29 Support Straps for Horizontal Runs • Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on FP2308 the horizontal plane, the maximum horizontal support straps length must be reduced by 18" (450 mm). Example: Maximum horizontal length No elbows = 10’ (3 m) 1 x 45° elbows = 8.5’ (2.6 m) 2 x 45° elbows = 7’ (2.1 m) • A minimum of an 8' (2.5 m) vertical rise is required. • Two sets of 45° elbows offsets may be used within the vertical sections. From 0 to a maximum of 8' (2.5 m) of vent pipe can be used between elbows. Figure 30 • The maximum angular variation allowed in the system is 270°. Figure 30 • The minimum height of the vent above the highest point of penetration through the roof is 2' (610 mm). 1 2 3 4 1 Example: Elbow 1 Elbow 2 Elbow 3 Elbow 4 Total Angular Variation = = = = = 90° 45° 45° 90° 270° 2 3 4 Figure 30 Maximum Elbow Usage FP2309 42D0200 FP2309 max elbow use A 25 vent installation 6000DV Gas Fireplace installation for vertical termination 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to Figure 31 to avoid cutting load bearing members. NOTE: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations. Offsets must fall within the parameters shown on Page 22, Figure 21. Roof Flashing Wall Strap 2. Set fireplace in desired location. Drop a line plumb down from the ceiling to the position of the flue exit. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole a this point. Drop a plumb line from the inside of the roof to the ceiling locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point. 45° Elbows FP1669 flat ceiling installation 1. Cut a 9Z\x" (241 mm) square hole in the ceiling using the locating hole as a center point The opening should be framed to 9Z\x" x 9Z\x" (241 x 241 mm) inside dimensions as shown in Figure 32 using framing lumber the same size as the ceiling joist. If the area above the ceiling is an insulated ceiling or a room, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. Figure 32. Otherwise, install firestop below the framed hole. 2. Assemble the desired lengths of pipe and elbows necessary to reach from the burner system flue up through the firestop. Be sure pipe and elbow connections are fully twist-locked. Page 20, Figure 17 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof). The 9Z\x" x 9Z\x" (241 x 241 mm) hole must be measured on the horizontal. Actual length may be larger depending on the pitch of the roof. There must be a 1" minimum clearance from the vent pipe to combustible materials. (Insulation should be considered a combustible material) Frame the opening as shown on Page 20, Figure 16. Ceiling Firstop Figure 31 Offset with Wall Strap and 45° Elbows Nails FP1969 offset w/ wallstrap FP1969 Firestop Figure 32 If area above is a room, install firestop above framed hole as shown " 9/ 1 2 9 1/ 2 " FP1969 firestop w room above FP1970 Nails Firestop Figure 33 If area above is not a room, install firestop below framed hole as shown 42D0200 26 FP1970 firestop no room vent installation 6000DV Gas Fireplace 4. Connect a section of pipe and extend up through the hole. NOTE: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose. Refer to Page 25, Figure 29. Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air. 5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing. There must be a 1" clearance from the vent pipe to combustible materials. 6. Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements. NOTE: You must increase vent height for steep roof pitches. Nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem. NOTE: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure to meet the minimum allowable clearances to combustibles. Do not fill any of the required clearance spaces with insulation. 42D0200 27 fireplace installation 6000DV Gas Fireplace check gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. A qualified installer or service person must connect appliance to gas supply. Follow all local codes. CAUTION WARNING Installing gas piping to fireplace / burner system location For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply. installation items needed Before installing fireplace and burner system, make sure you have the items listed below. • External regulator • Piping (check local codes) • Sealant (resistant to propane/LP gas) (supplied by installer) • Test gauge connection* • Sediment trap (recommended) • Equipment shutoff valve* • Tee joint • Pipe wrench • approved flexible gas line with gas connector (if allowed by local codes — not provided) * A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your dealer. External Regulator 100 gal. (min) Propane/LP Supply Tank CAUTION For propane/LP connections the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 34. Pointing the vent down protects it from freezing rain or sleet. Use only new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, Section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (listed on data plate) at the maximum flow rate (BTU/hr). Undue pressure loss will occur if the pipe is too small. Vent Pointing Down When using copper of flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT. FP1977 Figure 34 External Regulator with Vent Pointing Down (Propane/LP Only) 28 FP1977 external regulator 42D0200 6000DV Gas Fireplace Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION WARNING fireplace installation A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be installed upstream of the appliance. Figure 35 NOTE : The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CSA-B149 (1 or 2) Installation Code. A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 35 Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves. CAUTION IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the fireplace. Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 35. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly. CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap* Approved Flexible Gas Line Tee Joint Sediment Trap/Drip Leg Pipe Nipple Cap Figure 35 Gas Connection FP1978 gas connection 42D0200 3" M ini mu m Natural Gas From Gas Meter (4.5" w.c. to 10.5" w.c. Pressure) Propane/LP From External Regulator (11" w.c. to 13" w.c. Pressure) 29 Millivolt & electronic CHECK GAS PRESSURE and Electrical installation 6000DV Gas Fireplace WARNING 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 30" (762 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve. 3. After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/50 water Pressure and soap or a gas sniffer. Test “IN” 4. To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to Pressure LO to get minimum pressure. Test “OUT” HI/LO 5. To check gas pressures at valve, turn captured screw Knob counter clockwise 2 or 3 turns and then place tubing Pilot Adjustment Screw to pressure gauge over test point. Turn unit to high. Figure 36. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks. FP1979 Figure 36 Gas Pressure Check at Gas Valve FP1979 Millivolt gas valve Do not use open flame to check for gas leaks. Electrical Wiring This fireplace will work without any electrical supply. Electricity is only needed to operate blower. 30 Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1. CAUTION WARNING NOTE: If installed in mobile home, fireplace must be bolted securely to floor. Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 42D0200 Electrical installation 6000DV Gas Fireplace Remote Wall mounted Switch A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 37. Do not extend beyond the wall switch wire length provided. NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code. OPTIONAL REMOTE WALL SWITCH ON HI ON OFF PILOT LO TH TP TH/TP ON OFF RS OFF OPTIONAL REMOTE WALL SWITCH ON OFF WARNING Figure 37 Wiring Diagram for Wall Switch FP1980 Dv wiring diagram 42D0200 Do not connect wall switch to (110 V) circuit. 31 Electrical installation Electronic Pilot Ignition Wiring WARNING 6000DV Gas Fireplace Do not connect 110-120V AC to the Remote Wall Switch. The appliance will malfunction. Figure 38 Remote Wall Switch Wiring Diagram Remote Wall Switch FP2551 remote switch wiring Position the wall switch. Do not extend beyond the 15 feet of wire. Optional DC Remote Systems These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with the remote. 1. Plug in remote connector wire to remote receiver. 2. Connect the wire terminal from the remote receiver. This replaces the 15' wall switch connection to the switch. Figure 38. 3. Mount remote control receiver at junction box (for your wall switch). 32 42D0200 glass removal 6000DV Gas Fireplace Glass Frame Removal All three (3) glass frames are replaced the same way. 1. Release two clamps on bottom of fireplace. Figure 39 2. Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace. 3. Set glass frame aside. Glass Frame Clamp Three Tabs FP2310 Clamp ! WARNING WARNING Figure 39 Remove Glass Frame Each clamp has a quick spring force. When reinstalling clamps, keep fingers clear. Remove FP2310 control panel to operate middle clamp on 500 and 600 units. remove glass HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 42D0200 33 LOG PLACEMENT 6000DV Gas Fireplace Before you begin — This unit is supplied with eight ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers. WARNING The positioning of the logs is critical to the safe and clean operation of this heater. Excessive sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones or vermiculite to the heater. Only use the logs supplied with the unit. Failure to position the parts in accordance with diagrams below or to use only parts specifically approved for this heater may result in property damage or personal injury. Install logs and rock wool (ember material) in firebox 1. Remove glass frame. Refer to Glass Frame Removal, Page 33. 2. Carefully remove logs from wrapping. 3. Place left log (#1) on left end of grate. Line up two (2) pin holes in bottom of log with two (2) pins on grate. Log #1 will always be to the left of the control panel. Figure 40 4. Place right log (#2) on right end of grate. Line up three (3) pin holes in bottom of log with three (3) pins on grate. Figure 41 Grate Right Log (#2) Left Log (#1) Pins LG638 Control Panel Pins Figure 40 Install Left Log (#1) LG638 DV6000 left log Control Panel Figure 41 Install Right Log (#2) 42D0200 34 LG639 log placement 6000DV Gas Fireplace Bottom Center Back Log (#3) 5. Position left end of bottom center back log (#3) beside rear end of left log (#1). Line up pin on grate with pin hole in bottom of center back log (#3) Snug right end of bottom center back log (#3) to the middle of right log (#2). Figure 42 6. Line up pin holes on bottom front log (#4) with pins on grate. Figure 43 Pin Bottom Front Log (#4) LG640 Pins Figure 42 Install Bottom Center Log (#3) LG640 DV6000 bot ctr back log Left Top Log (#5) Figure 43 Install Bottom Front Log (#4) LG641 Cutout of Bottom Front Log LG641 7. Place back end log of left top log (#5) bottom front on cutout of bottom front log (#4). Position front of left top log (#5) on grate prong two. Figure 44 Figure 44 Install Left Top Log (#5) LG642 42D0200 Grate Prong Two 35 6000DV Gas Fireplace log placement Top Log #6 Grate Prong Four Cutout on Bottom Center Log 8. Place Y-Shaped end of top log (#6) on on prong four of back of grate. Position other end of top log (#6) in cutout of bottom center log (#3). Figure 45 Control Panel Figure 45 Install Top Log (#6) L643 DV6000 top log 9.Break up rock wool (ember material) into dime-sized pieces. Place evenly across burner surface and mesh of grate. Figure 46. Do not exceed 1" depth of coverage. Figure 46 Rock Wool Placement Rock Wool 42D0200 36 LG644 6000DV Gas Fireplace AIR RESTRICTOR ADJUSTMENT The fireplace is equipped with a restrictor plate that is located inside the top chamber of the fireplace. Depending upon the vent configuration, you may be required to adjust the restrictor position 1. Remove glass frame. Refer to Glass Frame Removal, Page 33. 2. Using a Phillips screw driver, loosen the screw that secures the air restrictor. Do not back the screw all the way out. 3. Slide the baffle on top of the restrictor plate to block a percentage of the grille opening. Refer to the chart below for recommended settings. Note: All the settings above are based on the testing at the factory and provided as a guide for startup. On certain applications, adding a restrictor disc will help to achieve flame aesthetics. Flue Opening Air Restrictor Figure 47 Adjust Baffle on Air Restrictor Plate Air Restrictor FP2311 Screw (Slide Left and Right) FP2311 air restrictor Venting Height (feet) 8 to 20 20 to 30 30 to 40 42D0200 % of Grille Opening 100% (Factory Setting) 75% 50% 37 OPERATING INSTRUCTIONS 6000DV Gas Fireplace WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in battery ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Turn off all gas to the appliance. • Open windows. • Do not attempt to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water. WARNING Lighting pilot for the first time initial lighting Never use an open flame to Purge air from the supply line as follows: check for gas leak. • Open main shutoff valve. • Unscrew main pressure test point. • Leave inlet test screw open until gas comes in. • When gas is flowing, tighten inlet screw immediately. leak testing 1. Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture. 2. Next check for gas leaks at the burner with soap and water mixture. 3. Check the pilot for gas leaks with soap and water mixture. Continued on next page 38 42D0200 OPERATING INSTRUCTIONS 6000DV Gas Fireplace approved leak testing method You may check for gas leaks with the following methods only: • Soap and water solution • An approved leak testing spray danger • Electronic sniffer Never check for gas leak with open flame! WARNING Lighting pilot for the first time If using a soap and water solution to test for leaks, DO NOT spray solution onto control body. NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers. Check for gas leaks in each of the following locations: • Pipe from the gas supply line connection to the gas valve • Burner connections • Field made joints / gas shutoff valve • Pilot • Factory made joints • Each joint or connection • All joints on valve and control body WARNING Lighting pilot The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation. The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury. 1. Depress and turn knob counterclockwise to pilot position. If the pilot does not stay lit, repeat steps 1 and 2. F PILOT ON OF 2. Depress fully and hold pilot gas knob. The electronic ignitor will automatically ignite the pilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn. PIL Figure 48 Pilot Position OT Continued on next page 42D0200 FP1935 control knob pilot 39 OPERATING INSTRUCTIONS 6000DV Gas Fireplace Lighting burner OFF RS The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. Figure 49 ON main burner switch Figure 49 On/Off/RS Switch Lighting the burner OFF ON Depress and turn the knob counterclockwise to the “ON” position. Figure 50. It will take less than four (4) seconds for the burner to ignite. Pilot position P ILOT Depress and turn knob to pilot position to keep burner off while maintaining the pilot light. Figure 51 PIL Figure 50 On Position OT PILOT ON FP1937 control knob on F Figure 51 Pilot Position OF PIL OT to turn off gas Depress and turn knob clockwise FP1935 to “OFF” position. Figure 52 control knob pilot Figure 52 Off Position 40 ON OFF PI L O T PIL OT 42D0200 cleaning and maintenance 6000DV Gas Fireplace Make sure the gas valve knob is in the “OFF” position. Wait at least five (5) minutes before start ing maintenance. Fireplace must be cold before starting maintenance. CAUTION Venting system A qualified agency should examine the venting system annually. Cleaning glass Allow glass to cool before cleaning. Do not clean glass when it is hot. Damage could occur. Clean the tempered glass periodically. Condensation will sometimes form on the glass during a cold startup. This is normal for all gas fireplaces. This condensation often attracts dust and lint to the surface of the glass. The initial paint curing of the appliance can also leave a slight film on the glass. Your should clean the glass after the first two weeks of use. After that, you should clean the glass no more than two or three times a season. Use a mild glass cleaner to clean the door. Do not use abrasive cleaners. They will damage the glass surface. pilot and burner flames Thermocouple Thermopile Figure 53 Typical Burner Flame Figure 54Typical Pilot Flame LG645 FP2312 LG645 1. Carefully remove log set, and embers (rock wool) from combustion chamber. DV6000 log flames 2. Vacuum burner compartment thoroughly. 3. Vacuum or brush with soft brush any dust off logs. 4. Remove any lint from main burner and pilot. 5. Carefully replace log set, and embers in their correct positions. Refer to Pages 34 through 36. 6. Replace door (if it has been removed). 7. Relight pilot. Refer to Page 39. 8. Turn on main burner. 42D0200 WARNING firebox cleaning Make sure clearances to combustibles leave room for maintenance and service. WARNING FP2312 Visually check pilot and burner flames periodically. Refer pilot flame to Figure 53 for typical burner flame. Refer to Figure 54 for typical pilot flame. Carefully reassemble and reseal fireplace properly after any cleaning or servicing. 41 6000DV Gas Fireplace troubleshooting Standing Pilot Ignition SYMPTOMPOSSIBLE CAUSEACTION 1. Spark ignitor will A. Wire disconnected. not light pilot after repeated triggering of B. Defective ignitor. piezo. C. No gas or low gas pressure. D. No Propane/LPG in tank 2. Pilot will not stay lit A. Defective thermocouple after carefully following lighting instructions. B. Defective valve 3. Pilot burning, valve A. Defective switch, wall knob turned to “ON”, switch, remote control or switch is turned to wire “ON” or “RS”, but burner will not ignite. B. Pilot flame too small C. Defective or malfunctioning thermopile D. Defective valve 42 A. Open door and check to make sure wire is connected to ignitor. B.Check for spark at electrode and pilot. If no spark and electrode wire is properly connected, replace pilot assembly. C. Check remote/manual shut off valve from fireplace. Low pressure can be caused by bent lines, restricted lines, low pressure line pressure. Consult with plumber or gas supplier. D. Check Propane/LPG tank. Refill tank. A. Check that thermocouple flame impinges on thermocouple. Clean and/or adjust pilot for maximum flame impingement. Ensure that the thermocouple connection at the gas valve is fully inserted and tight. Disconnect the thermocouple from the valve, place one millivolt lead wire on the tip of the thermocouple and the other meter lead wire on the thermocouple copper lead. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 mV, replace pilot assembly. B.If thermocouple is producing more than 15 mV, replace faulty valve. A. Check switch and wire for proper connection. Place jumper wires across terminals of switch. If burner comes on, replace defective switch.If the switch is OK, repeat the same procedure on remote control If burner comes on, replace remote control. Place jumper wire across wire at gas valves (terminals marked TH and TP/TH). If burner comes on, wires are faulty or connections are bad. Replace wire. B.If pilot flame is not close enough to the thermopile, adjust pilot flame. C.Check thermopile wire connections to make sure all are tight and that the thermopile is fully inserted into pilot assembly. Check thermopile with a millivolt meter. Connect leads to TP and TP/TH terminals on the control valve. If meter reading is below 325 mV, replace pilot assembly. D.Turn valve knob to “On” and switch to “ON.” Take a reading at the thermopile leads (TP & TP/TH) on the valve. If the meter reads greater than 175 mV and the burner does not light, replace defective valve. 42D0200 troubleshooting 6000DV Gas Fireplace electronic Ignition START 1.Turn gas supply off. 2.Turn ON/OFF switch to “ON” Power to module (24V Normal) NO Check: Line voltage (120VAC) Low voltage transformer (19.5 minimum VAC) ON/OFF switch Wiring connections NO Unplug ignition lead and check spark at module (24VAC normal). YES Is there a spark across ignitor sensor gap? Is spark OK? NO Replace module YES A.Check ignition cable ground wiring, ceramic insulator and gap. Correct if necessary. B.Does ignition cable show signs of melting or buckling? Take protective action to shield cable and boot from excessive temperatures. YES Turn on gas. Does pilot burner light? NO YES Does spark stop when pilot is lit? NO YES Does main burner light? NO YES Does system run until ON/OFF switch is in “OFF” position? YES END OF TROUBLESHOOTING 42D0200 NO A.Are all manual gas valves open? Are supply tubing and pressure good? Are pilot burner orifices blocked? B.Check electrical connections between module and pilot operator on gas control. C.Check for 24VAC across PV-MVPV terminals. If voltage is correct, replace gas control. If voltage is not correct, replace module. NOTE: If module goes into lockout, reset system. A.Check continuity of ignition cable and ground wire. B.Clean flame rod. C.Check electrical connections between flame rod and module. D.Is ceramic flame rod insulator cracked? E.Is pilot flame a steady blue? Does flame cover flame rod? If not, adjust pilot flame. Replace module if problem persists. A.Check for 24VAC across MV-MVPV terminal. Replace module if there is no voltage. B.Are electrical connections between module and gas control good? If connections are good, replace gas control or gas control operator. NOTE: If module goes into lockout, reset system. A.Check continuity of ignition cable and ground wire. NOTE: If ground is poor or erratic, shutdown may occasionally occur even though operation is normal at time of checkout. B.Is pilot flame a steady blue? Does flame cover flame rod? If above checks out, replace module. 43 troubleshooting 6000DV Gas Fireplace General troubleshooting SYMPTOMPOSSIBLE CAUSEACTION 6. Glass Soots A.Flame impingement on logs A. Install log set per the instructions Inspect the injector and air intake area. Make sure this area does not have any blockage from debris and clean. Check gas supply. 7. Flame burn blue and lifts off burner (ghosting) A.Insufficient oxygen being supplied A.Ensure that the vent cap is installed properly and free of debris. Ensure that the vent system joints are tight and have no leaks. Ensure that no debris has been blocking the inner air intake at the bottom back of the combustion chamber. Ensure that the glass is properly secure and latch. Make sure the glass panel edges do not touch any metal parts during thermal expansion. CAUTION WARNING Glass replacement and blower Always use gloves when handling broken glass. • Never operate fireplace if glass is broken. • Replace any glass that is chipped, cracked, or broken. Replacement glass assemblies MUST be supplied by fireplace manufacturer — No substitute materials may be used. optional Blower accessory - BLOT wiring diagram for Blower Attach Blower to T-Stat Green ON/OFF Wall Switch or Optional Variable Speed Switch Green FP2314 BLOT blower 120 VAC Blower White 120 VAC 60Hz Blower Plug Black 120 VAC Speed Control 44 Black Black Junction Box Factory Supplied Not Supplied 42D0200 replacement parts 6000DV Gas Fireplace LOGS 2 1 3 4 5 WARNING 6 LG646 DV6000 log parts Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Ref.DescriptionQtyNatural Propane 1. Left Bottom Log, #1 1 42D0401 42D0401 2. Right Bottom Log, #2 1 42D0400 42D0400 3. Bottom Center Log, #3 1 42D0403 42D0403 4. Bottom Front Log, #4 1 42D0402 42D0402 5. Left Top Log, #5 1 42D0404 42D0404 6. Top Log, #6 1 42D0405 42D0405 42D0200 45 replacement parts 6000DV Gas Fireplace REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER 5 6 4 7 3 *2 (2-Peninsula 2-See-through 1-Corner) WARNING 1 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 420200 DV6000 firebox parts Ref.DescriptionQtyNatural Propane 1. Junction Box 1 26D2128K 26D2128K 2. Large Glass Assy 1* 42D0364K 42D0366K (Peninsula, See-through) 2. Large Glass Assy 1* 42D0366K 42D0366K (Corner Left, Corner Right) 3. Small Glass Assy 1 42D0365K 42D0365K (Peninsula) 3. Small Glass Assy 1 42D0406K 42D0406K (Corner Left, Corner Right) 4. Small Floor Firebrick 1 26D7024 26D7124 5. Large Floor Firebrick 1 26D7123 26D7123 6. Small Wall Firebrick 1 26D7125 26D7125 7. Large Wall Firebrick 1 26D7128 26D7128 46 42D0200 REPLACEMENT PARTS 6000DV Gas Fireplace Standing Pilot – Millivolt Control 2I 2C 1 3 2T 2 5 4 6 7 8 9,10,11,12 Fuel Conversion Kits - Millivolt Natural Gas to LP 300 Conversion LP to Natural Gas 300 Conversion 42D0200 Kit #6000CKP Kit #6000CKN WARNING Ref.DescriptionQtyNatural Propane 1. Gas Valve Assy 1 37D0117 37D0118 2. Pilot Assy 1 20H2048 20H2049 2C. Replacement Thermocouple 1 37D1067 37D1067 2I. Replacement Igniter and Wire 1 37D1069 37D1069 2T. Replacement Thermopile 1 37D1068 37D1068 3. Flexhose w/ Shut-off Valve 1 26D6046 23D6046 4. Rocker Switch 1 41D0048 41D0048 420200 5. Piezo Igniter 1 14D0503 14D0503 DV6000 millivolt parts 6. Injector 1 42D0502 42D0503 7. Burner Assy 1 42D0501 42D0501 8. Wire Assy (Female) 1 44D0500 44D0500 8. Wire Assy (Male) 1 44D0501 44D0501 Accessories 9. Thermostatic Remote Control 1 RCT/TRC RCT/TRC 10. Remote Control On/Off 1 RCM/MRC RCM/MRC 11. Wall Switch Kit 1 MVWS MVWS 12. Wall Thermostat Kit 1 MVWTS MVWTS Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 47 REPLACEMENT PARTS 6000DV Gas Fireplace ELECTRONIC IGNITION 1 3 2 LO HI 5 4 6 7 9 8 48 SPARK #9 SENSE #8 24V #6 24V GND #5 WARNING GND (BURNER) #4 MV/PV #2 PV #3 MV #1 Ref.DescriptionQtyNatural Propane 1. Gas Valve Assy 1 37D0016 37D0017 2. Pilot Assy 1 37D0020 37D0021 3. Flexhose w/ Shut-off Valve 1 23D6046 23D6046 4. Rocker Switch 1 41D0048 41D0048 420200 5. Injector 1 42D0502 42D0503 DV6000 elect parts 6. Burner Assy 1 42D0500 42D0501 7. Wire Assy 1 54D2007 54D2007 8. Ignition Module 1 37D0325 37D0325 9. Transformer 1 37D0027 37D0027 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 42D0200 REPLACEMENT PARTS 6000DV Gas Fireplace Vent Components 1 7 4 8 9 HO T 5 2 3 6 11 10 Ref. Qty/Box 1. 1 1. 1 1. 1 2. 1 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 4. 6 4. 6 5. 6 5. 6 6. 6 6. 6 7. 6 8. 6 9. 6 10. 1 11. 1 42D0200 Simpson Durvent Description or MHSC Pt. No. Simpson Horizontal High Wind Termination 985 Horizontal Square Termination Cap w/ Built-in Vinyl Siding Standoff, Heat Deflector and Firestop Horizontal Rigid Pipe Termination Kit w/ Horizontal Termination Cap w/ BHRTK 420200 Built-in Vinyl Siding Standoff, Heat Deflector, Firestop, 90° Elbow and BHSTK DV6000 vent components 11" x 14B\," Adjustable Pipe Horizontal Flexible Pipe Termination Kit w/ Horizontal Termination Cap w/ BHSFTK Built-in Vinyl Siding Standoff, Heat Deflector, Firestop, 20" to 40" Flexible Pipe Adapter Vertical Termination 980 6" Pipe Length 908 9" Pipe Length 907 12" Pipe Length 906 24" Pipe Length 904 36" Pipe Length 903 48" Pipe Length 902 11" to 14B\," Pipe, Adjustable 911 17" to 24" Ppe, Adjustable 917 45° Elbow 945 45° Swivel Elbow 945G 90° Elbow 990 90° Swivel Elbow 990G Flashing, 0.12 to 6/12 Roof Pitch 943 Storm Collar 953 Firestop 963 Vinyl Siding Standoff 950 Restrictor Disc 45D0551 49 6000DV Gas Fireplace Massachusetts Residents Only — Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence. Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position. In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve. NOTE REGARDING VENT FREE PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve. CARBON MONOXIDE DETECTOR REQUIREMENTS (2)Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1. Installation of carbon monoxide detectors. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. 50 2. Approved Carbon Monoxide Detectors. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 3. Signage. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.” 4. Inspection. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. (b) Exemptions: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and 2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. (c) Manufacturer requirements — Gas Equipment Venting System Provided. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) Manufacturer requirements — Gas Equipment Venting System Not Provided. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer: 1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and 2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design 42D0200 6000DV Gas Fireplace Limited lifetime warranty policy Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs. Basic Warranty MHSC warrants the components and materials in your gas appliance to be free from manufacturing and material defects for a period of two years from date of installation. After installation, if any of the components manufactured by MHSC in the appliance are found to be defective in materials or workmanship, MHSC will, at its option, replace or repair the defective components at no charge to the original owner. MHSC will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase. This Limited Lifetime Warranty will be void if the appliance in not installed by a qualified installer in accordance with the installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) firebox/burner assembly damage by accident, neglect, misuse, abuse, alterations, negligence of others, including the installation thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or (3) incidental or consequential damage. All service work must be performed by an authorized service representative. This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness for purpose and of all other obligations or liabilities. MHSC does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. It states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also have additional rights not covered in the Limited Lifetime Warranty. MHSC reserves the right to investigate any and all the claims against the Limited Lifetime Warranty and decide upon method of settlement. IF WARRANTY SERVICE IS NEEDED... 1. Contact your supplier. Make sure you have your warranty, your sales receipt and the model/ serial number of your MHSC product. 2. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. 42D0200 51 Efficiency Ratings ModelEnerGuide Ratings Fireplace Efficiency (%) 6000DVNV 6000DVPN 6000DVNE 6000DVPE MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com