Download Manitowoc NEO UD0310AE Specifications
Transcript
Step 3 Disconnect the harvest float switch wire from the control board and place a jumper on the control board harvest float switch terminals. Bypass the freeze time lock-in feature by pressing the power button to cycle the ice machine off/on. Wait until water flows over the evaporator, then refer to chart. Result Correction 10 seconds into the freeze cycle the ice machine cycles from freeze to harvest and the control board harvest light energizes. The ice thickness float switch wire is causing the malfunction. The harvest light comes on, but the ice machine remains in the freeze cycle. The ice machine is in a 6 minute freeze lock - Cycle on/off and retest. The harvest light stays off and the ice machine remains in freeze. Replace the control board. 60 Part Number STH042 3/14