Download McQuay MMC Specifications
Transcript
Catalog Ducted Blower Split Systems Models: MDB 075-500 BR MDSB 200-500 BR MDB 125 CR MDB-R-2010 Table of Contents Nomenclature ................................................................................................................. 1 - Product Line Up .......................................................................................... 3 Features ...................................................................................................................... 5 Application Information - Operating Range ......................................................................................... 6 - Refrigerant Circuit Diagram ......................................................................... 7 - Controller ..................................................................................................... 9 - Installation .................................................................................................. 13 Sound Data ................................................................................................................... 21 - NC Curves .................................................................................................. 23 Selection Process - Fan Performance Chart.............................................................................. 31 Engineering and Physical Data - General Data .............................................................................................. 43 - Components Data ...................................................................................... 59 - Safety Devices ........................................................................................... 75 Performance Data ......................................................................................................... 80 - Performance Tables ................................................................................... 84 Dimensional Data .......................................................................................................... 96 Electrical Data .............................................................................................................. 104 Wiring Diagrams ........................................................................................................... 112 Servicing and Maintenance .......................................................................................... 121 Troubleshooting ............................................................................................................ 123 Exploded View and Part List ........................................................................................ 128 Note : Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations, and experienced with this type of equipment. Caution: Sharp edges and coil surfaces are a potential injury hazard. Avoid contact with them. Warning : Moving machinery and electrical power hazard. May cause severe personal injury or death. Disconnect and lock off power before servicing equipment. "McQuay" is a registered trademark of McQuay International. All rights reserved. c 2010 McQuay International. All rights reserved throughout the world. Bulletin illustrations cover the general appearance of McQuay International products at the time of publication. We reserve the right to change design and construction specifications at any time without notice. 141 CE Mark Without Expansion Device With air filter 200BR2 FBAA X X X X X 250BR2 FBAA X X X X X X 300BR3 FBAA X X X X X X 350BR3 FBAA X X X X X X 400BR4 FBAA X X X X X X 500BR4 FBAA X X X X X X 3 Vertical & Changeable Vertical as Standard Filter Horizontal & Not Changeable Horizontal & Changeable Refrigerant Control W/out Air Filter Capillary Tube TXV Without Marking W/out Contactor With Contactor W/out Control Nomenclature Handset MDSB Marking LCD Wired Handset Controller Sequential Controller Heat Pump Model Product Line Up MDB Classification Air Discharge X Heat Pump Model MMC 075CR 100BR 125BR 4 FBED X X X X X FBEJ X X X X X FBEC X X X X X FBEJ X X X X X FBEC X X X X X FBEJ X X X X X Gold Fin (NA549) Phase Sequencer Refrigerant Control With Accumulator Rivet "Made In Malaysia" Centrifugal Fan Without Expansion Device Capillary Tube Compressor TXV Reciproacating-Copeland Reciprocating Bristol Reciprocating-Maneurop Marking Scroll Maneurop Scroll-Copeland Without Marking Controller ETL CE Mark With Manual HP/LP With Auto HP/LP Without Contactor With Chint Contactor With Togami Contactor Nomenclature Classification Others X X X Fea tur es eatur tures Easy Maintenance The simple design concept has maintenance and servicing in mind. Access to the internal part of the unit can be from either side of the unit by loosening a few screws. Only for model MDB 075BR and 100BR with additional servicing panel from bottom Flexibility In Installation MDB075BR - MDB200BR models come with standard horizontal air discharge whereas MDB250BR - MDB500BR models come with standard vertical air discharge. However, the range from MDB150BR - MDB500BR are designed to cater for either horizontal or vertical air discharge application. Versatility Multiple rooms can be cooled together at the same time by using just one unit of fan coil unit. Fresh Air For Healthy Living Fresh air can be introduced into the building through the design of fresh air intakes. This will help to improve the indoor air quality. Superior Air Distribution For Comfortable Living The conditioned air can be effectively distributed to every corner of the room through the ducting and this ensure a more pleasant environment for comfort living. Flexibility Of Air Supply McQuay MDB series using belt driven fan such as that the air volume and static required can be adjusted according to the requirement. This flexibility allow for wider application. 5 Applica tion Inf or ma tion pplication Infor orma mation Operating Range Ensure the operating temperature is in allowable range. Cooling only Outdoor temp. (°CDB) Cooling 46 Caution : 35 STD The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 19 LOW AMBIENT KIT 0 24 15 Indoor temp. (°CWB) Heatpump Heating Cooling Outdoor temp. (°CDB) Outdoor temp. (°CWB) 18 6 STD 46 35 STD 19 LOW AMBIENT KIT 0 -9 15 21 27 15 Indoor temp. (°CDB) 24 Indoor temp. (°CWB) 6 Refrigerant Circuit Diagrams MODEL : MMC075CR 7 MODEL : MMC100/125BR 8 Controllers Electrical Connection Wiring regulations about wire diameter differs from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations. General Precaution Ensure that the rated voltage of the unit correspond to the name plate before carrying out proper wiring according to the wiring diagram. Provide a power outlet to be used exclusively for each unit. A power supply disconnect and a circuit breaker for overcurrent protection should be provided in the exclusive line. The unit must be GROUNDED to prevent possible hazard due to insulation failures Every wiring must be firmly connected. Every wiring should not touch the refrigerant piping, compressor and any moving parts of fan motor. Operational Check After all wiring is completed and the system is charged with refrigerant, make sure the unit is operating properly. Check that : Condenser fans are running with warm air blowing off the condensing unit. Evaporator blowers are running and discharging cool air from ducts. Suction line and liquid line pressures are in the region of 75 psig and 275 psig respectively. Sequential Controller Lcd Operating Instructions (Standard for cooling and heatpump units) 1. Sequential controller LCD display A B C D E F G H I : Time display : Error indication : Compressor running display (up to 4 compressors) : Key lock display : Heater display (up to 2 heaters) : Energy saving mode display : Compressor defrost cycle display (up to 4 compressors) : Operation mode display : Temperature set display 2. Operating Guide 2.1 ON/OFF key Press once to start the air conditioning unit. Press again to stop the unit. The operation lamp next to the key lights up and goes off respectively when the unit is running or not running. Caution : In the case when the ON/OFF key is pressed immediately after the operation is stopped, the unit will not restart until 3 minutes later to protect the compressor. 9 2.2 Selecting Operation Mode Press the MODE key to select the type of operating mode. Consecutive press of the key switches the operation over “COOL”, “HEAT”, “AUTO” and “FAN” 2.3 SAVE Mode Press the SAVE key to select the energy saving function. This option is only available for “COOL”, “HEAT” and “AUTO” modes. 2.4 Auxiliary Electric Heater If the “HEAT” mode provides insufficient heating to a room even at the highest temperature setting (30°C), press the HEATER key to activate the auxiliary electric heater. For models with two heaters, consecutive press of the key allows the selection of one or both heaters active. 2.5 Temperature Setting To set the desired room temperature, press or to increase or decrease the set temperature in the range of 16°C to 30°C. Press both and simultaneously to toggle between °C and °F setting. 2.6 Time Setting Real time Clock Press the CLOCK key once to activate set clock mode. Press again to disable set clock mode. Under set clock mode, the time of the present day can be set by pressing the respective MINUTE, HOUR and DAY key. 7days timer Press the ON TIMER key to activate autoON timer mode. Under this mode, press the respective MINUTE, HOUR and DAY key to select the time of the week when the air-conditioning unit is to automatically start running. Press the ON TIMER key again to save the setting. Press the OFF TIMER key to activate autoOFF timer mode. Under this mode, press the respective MINUTE, HOUR and DAY key to select the time of the week when the air-conditioning unit is to automatically stop running. Press the ON TIMER key again to save the setting. Then to activate the 7days timer, press and hold the TIMER ACTIVE key until the word “TIMER ACTIVE” appears on the LCD screen. Repeat the same step to disable the 7days timer. 2.7 Other Function Key Lock Press the MINUTE key 3 times consecutively to activate the key lock. A “KEY LOCK” symbol will appear on the LCD screen. At this point, only the ON/OFF key is valid. To disable the key lock, again press the MINUTE key 3 times consecutively. Test run Press the TEST key 2 times consecutively to test run the unit. 10 3. Error Code When the system is on and an error occurs, the ON/OFF LED on the LCD panel will blink and an error code is shown. When the system is off and there is a thermistor error, the ON/OFF LED is off but the error code is still displayed. Each error code represents different message as below Error Error Possible fault code E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14 E15 E16 E17 E18 Possible fault code Require manual reset (possible causes) Compressor 1 high temperature (overload) Compressor 2 high temperature(overload) Compressor 3 high temperature(overload) Compressor 4 high temperature(overload) Compressor 1 high pressure trip / contact open Compressor 2 high pressure trip / contact open Compressor 3 high pressure trip / contact open Compressor 4 high pressure trip / contact open Compressor 1 trip / low R-22 / outdoor abnormal Compressor 2 trip / low R-22 / outdoor abnormal Compressor 3 trip / low R-22 / outdoor abnormal Compressor 4 trip / low R-22 / outdoor abnormal Room sensor short Room sensor open Indoor coil sensor 1 short Indoor coil sensor 2 short Indoor coil sensor 3 short E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 E33 E34 E35 Indoor coil sensor 4 short Indoor coil sensor 1 open Indoor coil sensor 2 open Indoor coil sensor 3 open Indoor coil sensor 4 open Outdoor coil sensor 1 short Outdoor coil sensor 2 short Outdoor coil sensor 3 short Outdoor coil sensor 4 short Outdoor coil sensor 1 open Outdoor coil sensor 2 open Outdoor coil sensor 3 open Outdoor coil sensor 4 open Compressor 1 de-ice Compressor 2 de-ice Compressor 3 de-ice Compressor 4 de-ice 4. Installation Of Lcd Remote Controller 4.1 Accessories The following accessories are included. If any part is missing, contact your dealer immediately. 1 Remote controller 2 Wooden screw 4.1 x 16 (2 pieces) 3 Instruction manual 4.2 Stepbystep guide i) First, open up the casing of the LCD remote controller into its top and bottom case using a screwdriver. To do this, insert the screwdriver into the lower slot and slide it in the outward direction. ii) Fix the bottom case onto the wall with the 2 wooden screws provided. Then, insert the 4 connecting wires (from the main board) through the slot on the lower right. iii) Connect one end in each of the 4 wires to the terminal block behind the top case as shown below. The wire that goes into the “GND” terminal at the top case must be connected at the other end to the “GND” terminal at the main board. The same goes for the “+5V”, “B” and “A” connection. iv) Fasten back the top and bottom case into place. Hook the two upper claws into their respective slots and snap the lower part shut. 11 5. Auto Random Restart When power resumed, the unit will automatically restart and operate at the previous setting as before power failure occurred. (Remove jumper at JH/JP1 will cancel the auto random restart function. Please refer to wiring diagram for the location of the JH/JP1). SLM AC-5300 (OPTIONAL) 1. “ON/OFF” switch • Press to start the air conditioner unit. • Press again to stop the unit. 6. “Sleep” mode • Press button to activate the sleep function can only be activated under “cool” or heating mode operation. When it is activated under “cool” mode operation, the set temperature will increase 0.5°C after 30 minutes, 1°C after 1 hour and 2°C after 2 hours. If it is actiaved under “HEAT” mode operation, the set temperature will be descreased 0.5°C after 30 minutes, 1°C after 1 hour and 2°C after 2 hours. 2. Temperature setting • Set the desired room temperature. • Press button to increase or decrease the set temperature. Setting range are between 16°C to 30°C (60°F to 80°F). 7. Air Swing • Press button to activate the automatic air swing function. 3. Operation Modes • Press the “mode” button for select the type of operating mode. 8. Sensor • Infra red sensor to receive signals from wireless controller. - Cooling Only : COOL, DRY, FAN - Heat Pump : AUTO, COOL, DRY, HEAT, FAN (AUTO mode is represented by bothCOOL and HEAT LED light on) 9. LED Display • To display the set temperature (in °C) and timer delay setting (in hours). 4. Fan Speed selection • Press the button until the desired fan speed is achieved. 10. Transmission source • To transmit signals to the air conditioner. 5. Timer • Press the set button to select the switch timer of the air conditioner unit (the setting range is between 1 to 10 hours). 12 Installation Indoor Preliminary Site Survey a) Electrical supply and installation is to confirm to local authority's (e.g. National Electricity Board) codes and regulations. b) Voltage supply fluctuation must not exceed +/- 10% of rated voltage. Electricity supply line must be independent of welding transformers which can cause supply fluctuation. c) Ensure that the location is convenient for wiring and piping. Mounting a) For ceiling mounted models, locate a position where piping and ducting work can be kept to a minimum. Ensure that overhead supports are strong enough to hold the unit's weight. Position hanger rods and check for alignment with the unit. Check that hangers are secure and that the base of fan-coil unit is level in two horizontal directions. DRAINAGE PIPE SIDE Pipings Do not use contaminated or damaged copper tubings. If pipings, evaporator or condenser are exposed or had been opened for 15 seconds or more, vacuum and purge with field supplied refrigerant. Generally, do not remove plastic/rubber plugs/caps from fittings, tubings and coils until ready to connect suction or liquid line into fittings. Operational Check After all electrical wiring is completed and the system is charged with refrigerant, make sure unit is operating properly. Check that: a) Condenser fans are running, with warm air blowing off the condenser coil. b) Evaporator blowers are running and discharging cool air. c) Suction line inside condensing unit feels cool. d) Liquid line inside condensing unit feels warm. Electrical Connection As wiring regulations differ from country to country, please refer to your LOCAL ELECTRICAL CODES for field wiring regulations and ensure that these are complied with. Besides, observe the following general precautions: a) Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work. b) Provide a power outlet to be used exclusively for each unit. A power supply disconnect and a circuit breaker for over-current protection should be provided in the exclusive line. c) The unit must be GROUNDED to prevent possible hazard due to insulation failure. d) All wiring must be firmly connected. e) Electrical wiring must not touch the refrigerant piping, compressor and any moving parts of the fan motors. 13 Outdoor Location For Installation Of The Condensing Units As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected should fulfill the following requirements:a) Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unit cannot be drawn in again (as in the case of short circuit of hot discharge air). Allow sufficient space for maintenance around the unit. b) Ensure that there is no obstruction of air flow into or out of the unit. Remove obstacle which block air intake or discharge. c) The location must be well ventilated, so that the unit can draw and distribute plenty of air thus lowering the condensing temperature. d) A place capable of bearing the weight of the outdoor unit and isolating noise and vibration. e) A place protected from direct sunlight. Otherwise use an awning for protection, if necessary. f) A place where the hot air discharge and operating sound level will not annoy the neighbours. g) The location must not be susceptible to dust or oil mist. CAUTION: If the condensing unit is operated in an atmosphere containing oils (including machine oils), salt (coastal area), sulphide gas (near hot spring, oil refinery plant), such substances may lead to failure of the unit. 14 Field Piping To ensure satisfactory operation and performance, the following points should be noted for the field piping arrangements of the complete refrigerant cycle. a) Liquid loops or oil traps must be provided according to the position of the outdoor and the indoor units (depending on whether the indoor unit is above or below the outdoor unit). b) Field supplied filter dryer should be provided as close to the expansion valve(s) of the indoor unit (evaporator) as possible. c) Field supplied sight glass must be assembled and mounted next to filter dryer. Maximum Pipe Length And Maximum Number Of Bends When the pipe is too long, the required refrigerant quantity increases. Both the capacity and reliability drops as a result. As the number of bends increases, system piping resistance to the refrigerant flow increases, thus lowering the cooling capacity and the compressor may become defective. If the height difference between the evaporator and the condenser is excessive, the cooling capacity drops, the lubricating oil return is retarded, affecting the compressor efficiency adversely. Always choose the shortest piping path and follow the recommendations as shown below :- Model MMC 075CR MMC 100/125BR Max. elevation, m (ft) 25 (82.0) 25 (82.0) Max. Total Length, m (ft) 45 (147.6) 45 (147.6) Max. of Bends 8 8 25m 25m CAUTION: 1) Our guarantee on the performance of our air-conditioners is strictly revoked if the height, length and/ or the number of bends of the refrigerant piping system installed is beyond the limit above. 2) Bendings must be carefully made so as not to crush the pipe. Use a pipe bender to bend a pipe as far as possible. Maximum Allowable Piping Length & Elevation Difference 15 Installation Clearance When two or more outdoor units are installed in a location, they must be positioned such that one unit will not be taking the hot discharge air from another to avoid hot air short circuiting. This also applies when two or more units are installed one above the other. Below are the installation clearance guidelines : Model MMC 075CR MMC 100BR MMC 125BR 2 x MMC 100BR 2 x MMC 125BR A (mm) 300 500 500 700 700 B (mm) 500 300 300 300 300 C (mm) 1,200 1,200 1,200 1,500 1,500 Model 3 x MMC 100BR MMC 100BR + 2 x MMC 125BR 4 x MMC 100BR 4 x MMC 125BR A (mm) 1,000 1,000 1,000 1,000 B (mm) 300 300 300 300 C (mm) 2,000 2,000 2,000 2,000 16 Guidelines Of Field-charging Air Conditioning Systems With Scroll Compressors These guidelines are intended for use with Scroll compressors only with R22, R407C, R134a, R404A, R507, and R410A refrigerants. They do not apply to reciprocating compressors or competitive Scroll compressors. Field-charging - Some Precaution Points Scroll compressors have a very high volumetric efficiency and quickly pump a deep vacuum if there is insufficient refrigerant in the system or if refrigerant is added too slowly. Operation with low suction pressure will quickly lead to very high discharge temperatures. While this process is happening, the scrolls are not being well lubricated - scrolls depend on the oil mist in the refrigerant for lubrication. A lack of lubrication leads to high friction between the scroll flanks and tips and generates additional heat. The combination of heat of compression and heat from increased friction is concentrated in a small localized discharge area where temperatures can quickly rise to more than 300°C. These extreme temperatures damage the Scroll spirals and the orbiting Scroll bearing. This damage can occur in less than one minute especially on larger compressors. Failure may occur in the first few hours or the damage done during field charging may show up some time later. Other typical field charging problems include undercharging, overcharging, moisture or air in the system etc. In time each one of these problems can cause compressor failure. Equipment Minimal equipment is required for field charging. The minimum equipment required to do a satisfactory job is:Set of service gauges Hoses Vacuum pump Vacuum gauge Scales Thermometer Charging Hoses Most field-charging is done using standard service hoses. Hoses are made in different colors with different working pressures and with different leak rates but the most important point is the presence or absence of Shredder valve depressors. Shredder valve depressors severely restrict the flow through the service hoses. This slows evacuation and vapor charging dramatically. In most cases the Shredder depressor can be removed but it is simpler to have one set of hoses with and one set without Shredder depressors. Hose with Shredder valve Depressor Hose without Shredder valve Depressor Hose selection is important depending whether the system is being evacuated or charged. Charging liquid from the cylinder into the liquid line should be carried out using an open hose connected to an unrestricted fitting. This will reduce charging time. 17 Shredder valves Typical service valves found on the outdoor unit Shredder core Shredder valve with Shredder valve with core removed core in place Most split systems have a suitable connection on the outdoor unit Shredder valves provide easy system access for pressure reading and addition of refrigerant. On small systems, they provide a reasonable connection for evacuation also. However, Shredder valves and the hoses connected to them can cause very severe pressure drops and can multiply evacuation time by a factor of 4 or 5. On the positive side, Shredder valves provide a restriction that slows the speed of liquid charging into the suction side. When a pressure drop is desirable (charging liquid into suction), connect via a Shredder valve. When a pressure drop is detrimental (evacuation), connect via an open fitting. How Much Refrigerant? The proper refrigerant charge should follow the volume as recommended by manufacturer and recommendation should be followed by the installer. Refer to the table of Refrigerant Charge Level. If the installer cannot find the correct charge but the system must be started, refrigerant should be carefully added to the system until reasonable sub-cooling is measured in the liquid line and reasonable suction superheat is measured at the compressor suction. Suction and discharge pressures must be monitored carefully during the charging process. Charge Limits Copeland Scroll compressors have the different charge limits for different compressor models as shown in table below. If the total charge exceeds these limits, the system should have a crankcase heater and/or pump down cycle and/or accumulator to prevent liquid damage to the compressor. Some systems may require accumulators to limit liquid floodback even though the charge is lower than the published limit. Compressor Range Quest Summit Specter Model ZR46 to ZR81 ZR84 to ZR144 ZR90 to ZR19M lbs. 10 16 17 kg. 4.5 7.3 7.7 18 Charging Recommendations Charging liquid in a CONTROLLED manner into the suction side until the system is full. This recommendation does not hold true for reciprocating compressors where liquid charging into the suction side could cause severe damage. Charging Cylinder on Scale Close-up of Scale Carefully monitor the suction and discharge pressures - ensure that the suction pressure does not fall below 25 psig (1.7 bar) at any time during the charging process. CAUTION : Manifold Gauge will show cylinder pressure rather than suction pressure if the cylinder valve and Manifold valve "A" are both open. There are many ways of charging liquid in a "controlled manner" into the suction side:1. Use valve A on the manifold gauge set 2. Use the valve on the refrigerant cylinder 3. Charge through a Shredder valve 4. Use a hose with a Shredder valve depressor 5. Charge into the suction side at some distance from the compressor. 6. All of the above A Charging Procedures - Three phase compressors The fundamental procedure is the same as for single phase models but the compressor can run in the wrong direction on starting. If this happens reverse any two phases and start again. Short term reverse rotation will not damage the compressor. As compressors get larger the importance of correct field charging procedures grows exponentially. Unfortunately larger systems are often field charged which leads to many infant failures. All Specter compressors have internal discharge temperature protectors which are very effective in preventing dangerously high discharge temperatures during charging. The protection module will trip and lock the compressor out for 30 minutes. It is not normally necessary to wait 30 minutes for the module to reset. When the compressor has cooled down the module can be reset by breaking the power supply to the control circuit. Very often the serviceman does not understand why the module tripped and uses a jumper wire to bypass it. He continues to charge the system and removes the jumper when charging is complete. The compressor may or may not run with the protector back in the circuit but it is certain that the compressor has been damaged and premature failure is inevitable. 19 System Refrigerant Charge Level Guidelines Indoor Outdoor Liquid Pipe Gas Pipe Refrigerant Charge (kg/7.5m pipe length) MDB075BR MDB100BR MDB125CR MDB150BR2 MDB200BR2 MDB250BR2 MDB300BR3 MDB350BR3 MDB400BR4 MDB500BR4 MMC075CR MMC100BR MMC125BR MMC075CR x 2 MMC100BR x 2 MMC125BR x 2 MMC100BR x 3 MMC100BR + MMC125BR x 2 MMC100BR x 4 MMC125BR x 4 1/2 5/8 5/8 1/2 5/8 5/8 5/8 5/8 5/8 5/8 1 1-1/8 1-3/8 1 1-1/8 1-3/8 1-1/8 1-1/8 & 1-3/8 1-1/8 1-3/8 4.60 5.60 6.50 4.60 x 2 5.60 x 2 6.50 x 2 5.60 x 3 5.60 + (6.50 x 2) 5.60 x 4 6.50 x 4 MDSB200BR2 MDSB250BR2 MDSB300BR3 MDSB350BR3 MDSB400BR4 MDSB500BR4 MMC100BR x 2 MMC125BR x 2 MMC100BR x 3 MMC100BR + MMC125BR x 2 MMC100BR x 4 MMC125BR x 4 5/8 5/8 5/8 5/8 5/8 5/8 1-1/8 1-3/8 1-1/8 1-1/8 & 1-3/8 1-1/8 1-3/8 5.60 x 2 6.50 x 2 5.60 x 3 5.60 + (6.50 x 2) 5.60 x 4 6.50 x 4 Additional charge Based on liquid pipe size per meter length: Liquid Pipe Size, inch Additional Charge, kg/meter 1/4" 0.02 5/16" 0.04 3/8" 0.05 1/2" 0.1 5/8" 0.17 3/4" 7/8" 0.26 0.37 Note:The additional refrigerant charge amount recommended is a guideline for longer piping application. The actual charge required may be different from the guideline due to different application and variation in site conditions. 20 Sound Da ta Data SOUND PRESSURE LEVEL MDB-BR SERIES Model Speed High *MDB075BR 1/1 Octave Sound Pressure Level (dB, ref 20μPa) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Overall A (dBA) Noise Criteria 55 54 54 51 49 44 36 56 50 Medium 53 52 52 49 47 42 34 54 48 Low 52 50 49 47 45 40 32 52 46 High 56 55 55 52 50 45 37 57 51 *MDB100BR Medium 54 54 53 50 48 43 36 55 49 Low 53 52 51 48 46 41 35 53 47 *MDB150BR High 58 56 57 54 52 47 39 59 54 MDB200BR High 60 56 58 56 54 49 41 61 55 MDB250BR High 62 57 59 59 57 52 43 63 58 MDB300BR High 66 60 62 61 59 54 44 66 60 MDB350BR High 67 60 62 62 59 54 44 66 61 MDB400BR High 67 64 63 63 59 54 45 66 62 MDB500BR High 69 66 66 64 61 56 47 68 63 Microphone position: 1 m away from the service panel and 1 m height from the floor level (free return and the discharge air was ducted to adjacent room). Tested with 2m length duct at the air discharge outlet and air return inlet. *Microphone position: 1.4 m below the unit, discharge air is ducted to adjacent room, free return. MDB-CR SERIES 1/1 Octave Sound Pressure Level (dB, ref 20μPa) Model Speed MDB125CR High 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Overall A (dBA) Noise Criteria 58 56 57 54 52 47 39 59 54 Microphone position: 1.4 m below the unit, discharge air is ducted to adjacent room, free return. Tested with 2m length duct at the air discharge outlet and air return inlet. 21 SOUND POWER LEVEL MDB-BR SERIES Model Speed High MDB075BR MDB100BR 1/1 Octave Sound Power Level (dB, reference 1pW) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Overall A (dBA) 72 73 71 68 65 61 56 73 Medium 70 70 68 65 62 58 53 70 Low 68 67 65 62 59 55 50 67 High 74 74 73 70 67 63 58 75 Medium 72 73 71 68 65 61 56 73 Low 70 70 68 65 62 58 53 70 MDB150BR High 77 78 77 74 71 67 62 79 MDB200BR High 83 84 83 81 77 73 68 85 MDB250BR High 85 86 85 83 79 75 70 87 MDB300BR High 87 88 87 85 81 77 72 89 MDB350BR High 90 91 90 87 84 80 75 92 MDB400BR High 88 89 88 86 82 78 73 90 MDB500BR High 94 95 94 92 88 84 79 96 Remarks:Test with 5ft length discharge duct, terminated flush with the internal wall of reverberation room MDB-CR SERIES Model Speed MDB125CR High 1/1 Octave Sound Power Level (dB, reference 1pW) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Overall A (dBA) 77 78 77 74 71 67 62 79 Remarks:Test with 5ft length discharge duct, terminated flush with the internal wall of reverberation room 22 MDB075BR NC CURVE 70 60 Sound Pressure Level (dB, ref 20μPa) HI FAN NC-55 ME FAN 50 NC-50 LOW FAN NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDB100BR NC CURVE 70 60 Sound Pressure Level (dB, ref 20μPa) HI FAN ME FAN NC-55 LOW FAN 50 NC-50 NC-45 NC-40 40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 23 2000 4000 8000 MDB125CR NC CURVE 80 70 Sound Pressure Level (dB, ref 20μPa) NC-65 60 NC-60 HI FAN NC-55 NC-50 50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDB150BR NC CURVE 80 70 Sound Pressure Level (dB, ref 20μPa) NC-65 60 NC-60 HI FAN NC-55 NC-50 50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 24 2000 4000 8000 MDB200BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-60 HI FAN NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDB250BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-60 HI FAN NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 25 2000 4000 8000 MDB300BR NC CURVE 80 70 NC-65 Sound Pressure Level (dB, ref 20μPa) HI FAN 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDB350BR NC CURVE 80 70 Sound Pressure Level (dB, ref 20μPa) HI FAN NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 26 2000 4000 8000 MDB400BR NC CURVE 80 70 Sound Pressure Level (dB, ref 20μPa) HI FAN NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDB500BR NC CURVE 80 70 HI FAN Sound Pressure Level (dB, ref 20μPa) NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 27 2000 4000 8000 MDSB200BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-55 HI FAN 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDSB250BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-60 HI FAN NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 28 2000 4000 8000 MDSB300BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-60 HI FAN NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDSB350BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-60 HI FAN NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 29 2000 4000 8000 MDSB400BR NC CURVE 80 Sound Pressure Level (dB, ref 20μPa) 70 60 NC-60 HI FAN NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) MDSB500BR NC CURVE 80 70 NC-65 Sound Pressure Level (dB, ref 20μPa) HI FAN 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 Octave-band Frequency (Hz) 30 2000 4000 8000 Selection Pr ocess Process FAN PERFORMANCE CHART The following are the design requirements for MDB125CR unit: Model: MDB125CR Supply Air Quantity = 4250 External Static Pressure = 25 Step 1: From the fan curve (at 4250 CFM), Standard operating system; Total Static Pressure Internal Static Pressure External Static Pressure = = = 33.5 10.5 23.0 CFM mmAq mmAq mmAq mmAq External Static Pressure of 23.0 mmAq did not fulfill the design requirements. Step 2: Step 3: Therefore at 4500 CFM and 25 mmAq External static pressure, Total Static Pressure = 10.5 + 25 = 35.5 mmAq mmAq From the fan curve, the design requirement calls for RPM about 800, whereas the unit can only deliver RPM about 780 under the same CFM. Therefore, it is necessary to resize the pulley sizes. From the table: Motor pulley Blower pulley Motor RPM = = = 3.5" 6.5" 1425 In order to obtain 800 RPM, we recalculate the new blower pulley as: (while maintaining the motor pulley) Db = 3.5" x (1425/800) = 6.234" The nearest pulley size will be a diameter of 6" Recheck, with Db = 6" Blower pulley = = 1425 x (3.5/6) 831 We thus need to change the blower pulley from 6.5" to 6" in order to obtain the higher operating static pressure. Step 4: When the pulley is changed, the V-belt length must be rechecked. We have for horizontal air throw configuration: V-belt length, L = 2C + 1.57 (Db + Dm) = (2 x (180 x 0.03937")) + 1.57 (3.5" + 6") = 29.1" We thus can use a belt with a length of 30" where, Step 5: C Db Dm = = = distance between the centres of the two pulleys diameter of blower pulley diameter of motor pulley From the fan curve, we can also notice that the motor power input has increased. At the new operating point, the power is approximately 1.25 kW. By applying a safety factor of 1.2 to account for losses, we calculate that the motor power input requirement should be = 1.25 x 1.2 = 1.5 kW Thus, the existing motor is still sufficient to drive the blower with the smaller 6" pulley. Summary: i) Fan motor kW ii) Blower pulley diameter iii) V-belt size = = = 1.5 6" 30" 31 kW The following table summarizes the pulley data, motor size used for the MDB/MDSB series, as manufactured: Motor pulley, Dm Model Blower pulley, Db Pulley Centre Distance, C Motor V-pulley Taper # V-pulley Taper # Horizontal Vertical (in.) (mm) (in.) (mm) (mm) (mm) MDB 125CR 3.5 85 6.5 160 180 - 1.5 MDB 150BR 4.0 80 8.0 160 319 340 1.5 MDB/MDSB 200BR 4.0 80 7.0 140 314 330 3.0 MDB/MDSB 250BR 6.5 90 12.0 180 599 623 4.0 MDB/MDSB 300BR 6.5 95 12.0 180 599 623 4.0 MDB/MDSB 350BR 6.0 125 12.0 250 840 870 5.5 MDB/MDSB 400BR 5.5 106 13.0 250 732 782 5.5 MDB/MDSB 500BR 6.0 150 12.0 315 700 751 11.0 FAN PERFORMANCE CURVE MDB125CR 50 1kW 1.5kW 45 40 35.5 0.6kW 35 Total static pressure, mmAq 33.5 H 30 25 20 15 10.5 10 900RPM INTERNAL STATIC 5 800RPM 700RPM 0 0 2000 4250 4000 6000 Flowrate, CFM 32 8000 10000 12000 kW FAN PERFORMANCE CURVE MDB075BR 33 FAN PERFORMANCE CURVE MDB100BR 34 FAN PERFORMANCE CURVE MDB125CR 35 FAN PERFORMANCE CURVE MDB150BR 36 FAN PERFORMANCE CURVE MDB/MDSB200BR 37 FAN PERFORMANCE CURVE MDB/MDSB250BR 38 FAN PERFORMANCE CURVE MDB/MDSB300BR 39 FAN PERFORMANCE CURVE MDB/MDSB350BR 40 FAN PERFORMANCE CURVE MDB/MDSB400BR 41 FAN PERFORMANCE CURVE MDB/MDSB500BR 42 General Data - Heatpump MODEL INDOOR UNIT MDB250BR2 OUTDOOR UNIT MMC125BR x 2 232,000 Btu/h NOMINAL COOLING CAPACITY W 67,995 Btu/h 240,000 W 70,340 NOMINAL TOTAL INPUT POWER (COOLING) W 23,466 NOMINAL TOTAL INPUT POWER (HEATING) W 20,122 NOMINAL RUNNING CURRENT (COOLING) A 43.2 NOMINAL HEATING CAPACITY NOMINAL RUNNING CURRENT (HEATING) A 39.4 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.24 COP W/W 3.99 POWER SOURCE REFRIGERANT TYPE R22 REFRIGERANT CONTROL CONTROL OUTDOOR TXV HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT UNIT DIMENSION PACKING DIMENSION 417.2 / 1.67 dBA 63 1231 / 48.46 WIDTH mm/in 1866 / 73.46 DEPTH mm/in 1259 / 49.56 HEIGHT mm/in 1506 / 59.29 WIDTH mm/in 2034 / 80.08 DEPTH mm/in 1412 / 55.59 CONDENSATE DRAIN SIZE AIR FLOW kg/lb 343 / 756 mm/in 25.40 / 1.00 l/s / cfm 4248 / 9000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 169 / 372 SOUND PRESSURE LEVEL PACKING DIMENSION 3776 / 8000 Pa / in.wg. mm/in UNIT WEIGHT UNIT DIMENSION l/s / cfm HEIGHT SOUND PRESSURE LEVEL OUTDOOR UNIT WIRED CONTROL OPERATION AIR FLOW UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING 15.88 / ⅝ LIQUID mm/in GAS mm/in 34.92 / 1⅜ kg/lb 6.50 (x2) / 14.33 (x2) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 48 General Data - Heatpump MODEL INDOOR UNIT MDB300BR3 OUTDOOR UNIT MMC100BR x 3 296,400 Btu/h NOMINAL COOLING CAPACITY W 86,870 Btu/h 289,500 W 84,848 NOMINAL TOTAL INPUT POWER (COOLING) W 31,801 NOMINAL TOTAL INPUT POWER (HEATING) W 29,575 NOMINAL RUNNING CURRENT (COOLING) A 59.6 NOMINAL HEATING CAPACITY NOMINAL RUNNING CURRENT (HEATING) A 57.2 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.00 COP W/W 3.17 POWER SOURCE REFRIGERANT TYPE R22 REFRIGERANT CONTROL CONTROL OUTDOOR TXV HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT UNIT DIMENSION PACKING DIMENSION 325.5 / 1.31 dBA 66 1231 / 48.46 WIDTH mm/in 1866 / 73.46 DEPTH mm/in 1259 / 49.56 HEIGHT mm/in 1506 / 59.29 WIDTH mm/in 2034 / 80.08 DEPTH mm/in 1412 / 55.59 CONDENSATE DRAIN SIZE AIR FLOW kg/lb 346 / 762 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 164 / 361 SOUND PRESSURE LEVEL PACKING DIMENSION 4248 / 9000 Pa / in.wg. mm/in UNIT WEIGHT UNIT DIMENSION l/s / cfm HEIGHT SOUND PRESSURE LEVEL OUTDOOR UNIT WIRED CONTROL OPERATION AIR FLOW UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING 15.88 / ⅝ LIQUID mm/in GAS mm/in 28.58 / 1⅛ kg/lb 5.60 (x3) / 12.35 (x3) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 49 General Data - Heatpump MODEL MDB350BR3 INDOOR UNIT OUTDOOR UNIT MMC100BR x 1 NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY MMC125BR x 2 330,800 Btu/h W 96,952 Btu/h 336,500 W 98,623 NOMINAL TOTAL INPUT POWER (COOLING) W 33,873 NOMINAL TOTAL INPUT POWER (HEATING) W 29,787 NOMINAL RUNNING CURRENT (COOLING) A 62.8 NOMINAL RUNNING CURRENT (HEATING) A 58.2 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.17 COP W/W 3.72 POWER SOURCE R22 REFRIGERANT TYPE REFRIGERANT CONTROL CONTROL OUTDOOR TXV OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT SOUND PRESSURE LEVEL UNIT DIMENSION PACKING DIMENSION dBA 66 1486 / 58.50 WIDTH mm/in 2122 / 83.54 DEPTH mm/in 1259 / 49.56 HEIGHT mm/in 1766 / 69.53 WIDTH mm/in 2279 / 89.72 DEPTH mm/in 1412 / 55.59 AIR FLOW kg/lb 440 / 970 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 65 HEIGHT mm/in 946 / 37.24 946 / 37.24 WIDTH mm/in 1116 / 43.93 1116 / 43.93 DEPTH mm/in 939 / 36.96 SOUND PRESSURE LEVEL OUTDOOR UNIT 289.9 / 1.16 mm/in CONDENSATE DRAIN SIZE PACKING DIMENSION 4956 / 10500 Pa / in.wg. HEIGHT UNIT WEIGHT UNIT DIMENSION WIRED CONTROL l/s / cfm HEIGHT mm/in WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb TYPE SIZE REFRIGERANT CHARGE 939 / 36.96 1132 / 44.57 UNIT WEIGHT PIPE CONNECTION 4248 / 9000 164 / 361 169 / 372 BRAZING BRAZING 15.88 / ⅝ 15.88 / ⅝ LIQUID mm/in GAS mm/in 28.58 / 1⅛ 34.92 / 1⅜ kg/lb 5.60 / 12.35 6.50 (x2) / 14.33 (x2) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 50 General Data - Heatpump MODEL MDB400BR4 INDOOR UNIT MMC100BR x 4 OUTDOOR UNIT NOMINAL COOLING CAPACITY Btu/h 395,200 W 115,826 Btu/h 386,000 W 113,130 NOMINAL TOTAL INPUT POWER (COOLING) W 41,903 NOMINAL TOTAL INPUT POWER (HEATING) W 38,935 NOMINAL RUNNING CURRENT (COOLING) A 78.7 NOMINAL HEATING CAPACITY A 75.5 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.04 COP W/W 3.22 NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE R22 REFRIGERANT TYPE OUTDOOR TXV REFRIGERANT CONTROL CONTROL OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE (H/M/L) INDOOR UNIT SOUND PRESSURE LEVEL (H/M/L) UNIT DIMENSION PACKING DIMENSION dBA 66 1486 / 58.50 WIDTH mm/in 2274 / 89.52 DEPTH mm/in 1526 / 60.07 HEIGHT mm/in 1766 / 69.53 WIDTH mm/in 2431 / 95.81 DEPTH mm/in 1684 / 66.3 AIR FLOW SOUND PRESSURE LEVEL OUTDOOR UNIT 356.7 / 1.43 mm/in CONDENSATE DRAIN SIZE PACKING DIMENSION 5664 / 12000 Pa / in.wg. HEIGHT UNIT WEIGHT UNIT DIMENSION WIRED CONTROL l/s / cfm kg/lb 513 / 1130 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 164 / 361 UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING LIQUID mm/in GAS mm/in ⅝ 28.58 / 1⅛ kg/lb 5.60 (x4) / 12.35 (x4) 15.88 / 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 51 General Data - Heatpump MODEL INDOOR UNIT MDB500BR4 OUTDOOR UNIT MMC125BR x 4 464,000 Btu/h NOMINAL COOLING CAPACITY W 135,991 Btu/h 480,000 W 140,680 NOMINAL TOTAL INPUT POWER (COOLING) W 48,227 NOMINAL TOTAL INPUT POWER (HEATING) W 41,539 NOMINAL RUNNING CURRENT (COOLING) A 88.4 NOMINAL HEATING CAPACITY NOMINAL RUNNING CURRENT (HEATING) A 80.8 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.21 COP W/W 3.95 POWER SOURCE REFRIGERANT TYPE R22 REFRIGERANT CONTROL CONTROL OUTDOOR TXV HIGH EXTERNAL STATIC PRESSURE (H/M/L) INDOOR UNIT UNIT DIMENSION PACKING DIMENSION 393.7 / 1.58 dBA 68 1486 / 58.50 WIDTH mm/in 2274 / 89.52 DEPTH mm/in 1526 / 60.07 HEIGHT mm/in 1766 / 69.53 WIDTH mm/in 2431 / 95.81 DEPTH mm/in 1684 / 66.3 CONDENSATE DRAIN SIZE AIR FLOW kg/lb 606 / 1335 mm/in 25.40 / 1.00 l/s / cfm 4248 / 9000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 169 / 372 SOUND PRESSURE LEVEL PACKING DIMENSION 7080 / 15000 Pa / in.wg. mm/in UNIT WEIGHT UNIT DIMENSION l/s / cfm HEIGHT SOUND PRESSURE LEVEL (H/M/L) OUTDOOR UNIT WIRED CONTROL OPERATION AIR FLOW UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING 15.88 / ⅝ LIQUID mm/in GAS mm/in 34.92 / 1⅜ kg/lb 6.50 (x4) / 14.33 (x4) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 52 General Data - Heatpump MODEL MDSB200BR2 INDOOR UNIT MMC100BR x 2 OUTDOOR UNIT 197,600 Btu/h NOMINAL COOLING CAPACITY W 57,913 Btu/h 193,000 W 56,565 NOMINAL TOTAL INPUT POWER (COOLING) W 21,264 NOMINAL TOTAL INPUT POWER (HEATING) W 19,780 NOMINAL RUNNING CURRENT (COOLING) A 40.0 NOMINAL HEATING CAPACITY A 38.4 V/Ph/Hz 380~415 / 3 / 50 EER W/W 2.93 COP W/W 3.09 NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE R22 REFRIGERANT TYPE REFRIGERANT CONTROL CONTROL OUTDOOR TXV OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT SOUND PRESSURE LEVEL UNIT DIMENSION PACKING DIMENSION dBA 58 1015 / 39.96 WIDTH mm/in 1904 / 74.96 DEPTH mm/in 1107.5 / 43.60 HEIGHT mm/in 1206 / 47.48 WIDTH mm/in 2084 / 82.14 DEPTH mm/in 1188 / 46.77 AIR FLOW SOUND PRESSURE LEVEL OUTDOOR UNIT 158.2 / 0.64 mm/in CONDENSATE DRAIN SIZE PACKING DIMENSION 3021 / 6400 Pa / in.wg. HEIGHT UNIT WEIGHT UNIT DIMENSION WIRED CONTROL l/s / cfm kg/lb 220 / 485 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 164 / 361 UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING LIQUID mm/in GAS mm/in ⅝ 28.58 / 1⅛ kg/lb 5.60 (x2) / 12.35 (x2) 15.88 / 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 53 General Data - Heatpump MODEL INDOOR UNIT MDSB250BR2 OUTDOOR UNIT MMC125BR x 2 232,000 Btu/h NOMINAL COOLING CAPACITY W 67,995 Btu/h 240,000 W 70,340 NOMINAL TOTAL INPUT POWER (COOLING) W 23,466 NOMINAL TOTAL INPUT POWER (HEATING) W 20,122 NOMINAL RUNNING CURRENT (COOLING) A 43.2 NOMINAL HEATING CAPACITY NOMINAL RUNNING CURRENT (HEATING) A 39.4 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.24 COP W/W 3.99 POWER SOURCE REFRIGERANT TYPE R22 REFRIGERANT CONTROL CONTROL OUTDOOR TXV OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT SOUND PRESSURE LEVEL UNIT DIMENSION PACKING DIMENSION dBA 60 1378 / 54.25 WIDTH mm/in 1933.7 / 76.13 DEPTH mm/in 1243.5 / 48.95 HEIGHT mm/in 1590 / 62.59 WIDTH mm/in 2134 / 84.01 DEPTH mm/in 1437 / 56.57 AIR FLOW SOUND PRESSURE LEVEL OUTDOOR UNIT 417.2 / 1.67 mm/in CONDENSATE DRAIN SIZE PACKING DIMENSION 3776 / 8000 Pa / in.wg. HEIGHT UNIT WEIGHT UNIT DIMENSION WIRED CONTROL l/s / cfm kg/lb 343 / 756 mm/in 25.40 / 1.00 l/s / cfm 4248 / 9000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 169 / 372 UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING LIQUID mm/in GAS mm/in ⅝ 34.92 / 1⅜ kg/lb 6.50 (x2) / 14.33 (x2) 15.88 / 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 54 General Data - Heatpump MODEL INDOOR UNIT MDSB300BR3 OUTDOOR UNIT MMC100BR x 3 296,400 Btu/h NOMINAL COOLING CAPACITY W 86,870 Btu/h 289,500 W 84,848 NOMINAL TOTAL INPUT POWER (COOLING) W 31,801 NOMINAL TOTAL INPUT POWER (HEATING) W 29,575 NOMINAL RUNNING CURRENT (COOLING) A 59.6 NOMINAL HEATING CAPACITY NOMINAL RUNNING CURRENT (HEATING) A 57.2 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.00 COP W/W 3.17 POWER SOURCE REFRIGERANT TYPE R22 REFRIGERANT CONTROL CONTROL OUTDOOR TXV HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT UNIT DIMENSION PACKING DIMENSION 325.5 / 1.31 dBA 63 1378 / 54.25 WIDTH mm/in 1933.7 / 46.13 DEPTH mm/in 1243.5 / 48.95 HEIGHT mm/in 1590 / 62.59 WIDTH mm/in 2134 / 84.01 DEPTH mm/in 1437 / 56.57 CONDENSATE DRAIN SIZE AIR FLOW kg/lb 346 / 762 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 164 / 361 SOUND PRESSURE LEVEL PACKING DIMENSION 4248 / 9000 Pa / in.wg. mm/in UNIT WEIGHT UNIT DIMENSION l/s / cfm HEIGHT SOUND PRESSURE LEVEL OUTDOOR UNIT WIRED CONTROL OPERATION AIR FLOW UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING 15.88 / ⅝ LIQUID mm/in GAS mm/in 28.58 / 1⅛ kg/lb 5.60 (x3) / 12.35 (x3) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 55 General Data - Heatpump MODEL MDSB350BR3 INDOOR UNIT OUTDOOR UNIT MMC100BR x 1 NOMINAL COOLING CAPACITY MMC125BR x 2 330,800 Btu/h W 96,952 Btu/h 336,500 W 98,623 NOMINAL TOTAL INPUT POWER (COOLING) W 33,873 NOMINAL TOTAL INPUT POWER (HEATING) W 29,787 NOMINAL RUNNING CURRENT (COOLING) A 62.8 NOMINAL HEATING CAPACITY NOMINAL RUNNING CURRENT (HEATING) A 58.2 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.17 COP W/W 3.72 POWER SOURCE REFRIGERANT TYPE R22 REFRIGERANT CONTROL CONTROL OUTDOOR TXV OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE INDOOR UNIT SOUND PRESSURE LEVEL UNIT DIMENSION PACKING DIMENSION dBA 63 1652 / 65.03 WIDTH mm/in 2142.3 / 84.34 DEPTH mm/in 1335 / 52.55 HEIGHT mm/in 1868 / 73.54 WIDTH mm/in 2370 / 93.30 DEPTH mm/in 1537.4 / 60.52 AIR FLOW kg/lb 440 / 970 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 65 HEIGHT mm/in 946 / 37.24 946 / 37.24 WIDTH mm/in 1116 / 43.93 1116 / 43.93 DEPTH mm/in 939 / 36.96 939 / 36.96 HEIGHT mm/in 1132 / 44.57 1132 / 44.57 WIDTH mm/in 1282 / 50.47 1282 / 50.47 DEPTH mm/in 1112 / 43.78 1112 / 43.78 SOUND PRESSURE LEVEL OUTDOOR UNIT 289.9 / 1.16 mm/in CONDENSATE DRAIN SIZE PACKING DIMENSION 4956 / 10500 Pa / in.wg. HEIGHT UNIT WEIGHT UNIT DIMENSION WIRED CONTROL l/s / cfm UNIT WEIGHT kg/lb TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE 4248 / 9000 164 / 361 169 / 372 BRAZING BRAZING 15.88 / ⅝ 15.88 / ⅝ LIQUID mm/in GAS mm/in 28.58 / 1⅛ 34.92 / 1⅜ kg/lb 5.60 / 12.35 6.50 (x2) / 14.33 (x2) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 56 General Data - Heatpump MODEL MDSB400BR4 INDOOR UNIT MMC100BR x 4 OUTDOOR UNIT NOMINAL COOLING CAPACITY Btu/h 395,200 W 115,826 Btu/h 386,000 W 113,130 NOMINAL TOTAL INPUT POWER (COOLING) W 41,903 NOMINAL TOTAL INPUT POWER (HEATING) W 38,935 NOMINAL RUNNING CURRENT (COOLING) A 78.7 NOMINAL HEATING CAPACITY A 75.5 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.04 COP W/W 3.22 NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE R22 REFRIGERANT TYPE REFRIGERANT CONTROL CONTROL OUTDOOR TXV OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE (H/M/L) INDOOR UNIT SOUND PRESSURE LEVEL (H/M/L) UNIT DIMENSION PACKING DIMENSION dBA 64 1610 / 63.38 WIDTH mm/in 2320.3 / 91.35 DEPTH mm/in 1438 / 56.61 HEIGHT mm/in 1850 / 72.83 WIDTH mm/in 2431 / 95.71 DEPTH mm/in 1734 / 68.27 AIR FLOW SOUND PRESSURE LEVEL OUTDOOR UNIT 356.7 / 1.43 mm/in CONDENSATE DRAIN SIZE PACKING DIMENSION 5664 / 12000 Pa / in.wg. HEIGHT UNIT WEIGHT UNIT DIMENSION WIRED CONTROL l/s / cfm kg/lb 513 / 1130 mm/in 25.40 / 1.00 l/s / cfm 2832 / 6000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 164 / 361 UNIT WEIGHT TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE BRAZING LIQUID mm/in GAS mm/in ⅝ 28.58 / 1⅛ kg/lb 5.60 (x4) / 12.35 (x4) 15.88 / 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 57 General Data - Heatpump MODEL INDOOR UNIT MDSB500BR4 OUTDOOR UNIT NOMINAL COOLING CAPACITY MMC125BR x 4 Btu/h 464,000 W 135,991 Btu/h 480,000 W 140,680 NOMINAL TOTAL INPUT POWER (COOLING) W 48,227 NOMINAL TOTAL INPUT POWER (HEATING) W 41,539 NOMINAL RUNNING CURRENT (COOLING) A 88.4 NOMINAL HEATING CAPACITY A 80.8 V/Ph/Hz 380~415 / 3 / 50 EER W/W 3.21 COP W/W 3.95 NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE R22 REFRIGERANT TYPE OUTDOOR TXV REFRIGERANT CONTROL CONTROL OPERATION AIR FLOW HIGH EXTERNAL STATIC PRESSURE (H/M/L) INDOOR UNIT PACKING DIMENSION dBA 65 1610 / 63.38 WIDTH mm/in 2320.3 / 91.35 DEPTH mm/in 1438 / 56.61 HEIGHT mm/in 1850 / 72.83 WIDTH mm/in 2431 / 95.71 DEPTH mm/in 1734 / 68.27 CONDENSATE DRAIN SIZE AIR FLOW SOUND PRESSURE LEVEL OUTDOOR UNIT PACKING DIMENSION 393.7 / 1.58 mm/in UNIT WEIGHT UNIT DIMENSION 7080 / 15000 Pa / in.wg. HEIGHT SOUND PRESSURE LEVEL (H/M/L) UNIT DIMENSION WIRED CONTROL l/s / cfm kg/lb 606 / 1335 mm/in 25.40 / 1.00 l/s / cfm 4248 / 9000 dBA 65 HEIGHT mm/in 946 / 37.24 WIDTH mm/in 1116 / 43.93 DEPTH mm/in 939 / 36.96 HEIGHT mm/in 1132 / 44.57 WIDTH mm/in 1282 / 50.47 DEPTH mm/in 1112 / 43.78 kg/lb 169 / 372 UNIT WEIGHT BRAZING TYPE PIPE CONNECTION SIZE REFRIGERANT CHARGE LIQUID mm/in GAS mm/in ⅝ 34.92 / 1⅜ kg/lb 6.50 (x4) / 14.33 (x4) 15.88 / 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR b) HEATING - 21.1°C DB INDOOR AND 8.3°C DB / 6.1°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 58 Components Data - Heatpump MODEL INDOOR UNIT MDB075BR OUTDOOR UNIT MMC075CR TYPE INDOOR FAN CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL DIRECT DRIVE DIAMETER mm/in LENGTH mm/in 2 QUANTITY INDEX OF PROTECTION (IP) IP20 TYPE PROPELLER QUANTITY 1 ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 TYPE SCROLL OIL TYPE SONTEX 200LT cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 0.54 / 5.82 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 3 FIN PER INCH 12 SEAMLESS BARE COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.23 / 13.25 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 14 WASHABLE SARAN NET TYPE pc 2 LENGTH mm/in 622 / 24.5 WIDTH mm/in 433 / 17.0 THICKNESS mm/in QUANTITY AIR QUALITY 2513.8 / 85 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 203.00 / 8.00 PERMANENT SPLIT CAPACITOR TYPE INDOOR FAN MOTOR 282.70 / 11.13 FILTER SIZE INDOOR UNIT CASING OUTDOOR UNIT 12.70 / ½ ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 59 Components Data - Heatpump MODEL INDOOR UNIT MDB100BR OUTDOOR UNIT MMC100BR CENTRIFUGAL TYPE INDOOR FAN QUANTITY 1 MATERIAL ZINC COATED STEEL DIRECT DRIVE DIAMETER mm/in LENGTH mm/in 2 QUANTITY IP20 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 0.54 / 5.82 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 4 FIN PER INCH 12 SEAMLESS BARE COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 12 WASHABLE SARAN NET TYPE pc 2 LENGTH mm/in 622 / 24.5 WIDTH mm/in 433 / 17.0 THICKNESS mm/in QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 203.00 / 8.00 PERMANENT SPLIT CAPACITOR TYPE INDOOR FAN MOTOR 282.70 / 11.13 FILTER SIZE INDOOR UNIT CASING OUTDOOR UNIT 12.70 / ½ ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 60 Components Data - Heatpump MODEL INDOOR UNIT MDB125CR OUTDOOR UNIT MMC125BR TYPE INDOOR FAN CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY INDEX OF PROTECTION (IP) IP54 TYPE PROPELLER QUANTITY 1 ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 TYPE SCROLL OIL TYPE SONTEX 200LT cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.36 / 0.014 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 0.79 / 8.60 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 4 FIN PER INCH 12 INNER GROOVE MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.36 / 0.014 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 18 WASHABLE VILEDON TYPE pc 3 LENGTH mm/in 457 / 17.99 WIDTH mm/in 589 / 23.19 THICKNESS mm/in QUANTITY AIR QUALITY 3253.1 / 110 INNER GROOVE MATERIAL TUBE 762.00 / 30 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 381.00 / 15.00 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 394.97 / 15.55 FILTER SIZE INDOOR UNIT CASING OUTDOOR UNIT MATERIAL 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL COLOUR LIGHT GREY ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 61 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDB150BR2 OUTDOOR UNIT MMC075CR x 2 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY INDEX OF PROTECTION (IP) IP54 TYPE PROPELLER QUANTITY 1 ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 TYPE SCROLL OIL TYPE SONTEX 200LT cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.00 / 10.82 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 4 FIN PER INCH 12 SEAMLESS BARE COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.23 / 13.25 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 14 WASHABLE VILEDON TYPE pc 3 LENGTH mm/in 457 / 17.99 WIDTH mm/in 433 / 23.19 THICKNESS mm/in QUANTITY AIR QUALITY 2513.8 / 85 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 381.00 / 15.00 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 394.97 / 15.55 FILTER SIZE INDOOR UNIT CASING OUTDOOR UNIT MATERIAL 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL COLOUR LIGHT GREY ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 62 Components Data - Heatpump MODEL INDOOR FAN MDB200BR2 INDOOR UNIT OUTDOOR UNIT MMC100BR x 2 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.20 / 12.92 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 4 FIN PER INCH 12 SEAMLESS BARE COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 12 WASHABLE VILEDON TYPE pc 3 LENGTH mm/in 542 / 19.4 WIDTH mm/in 738 / 29.1 mm/in 50.8 / 2.00 QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 381.00 / 15.00 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 394.97 / 15.55 FILTER SIZE THICKNESS INDOOR UNIT CASING OUTDOOR UNIT ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 63 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDB250BR2 OUTDOOR UNIT MMC125BR x 2 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in TYPE INDOOR FAN MOTOR 1 QUANTITY IP54 PROPELLER TYPE 1 QUANTITY OUTDOOR FAN MATERIAL ALUMINIUM DRIVE DIRECT DIAMETER mm/in 1 IP54 TYPE SCROLL SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in THICKNESS mm/in mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.48 / 16.01 ROW 4 FIN PER INCH 14 INNER GROOVE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.36 / 0.014 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 18 TYPE WASHABLE VILEDON QUANTITY AIR QUALITY ⅜ THICKNESS MATERIAL TUBE 9.52 / 0.35 / 0.013 ALUMINIUM MATERIAL FIN 3253.1 / 110 SEAMLESS COPPER MATERIAL INDOOR COIL 762.00 / 30 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) TUBE 459.99 / 18.11 SQUIRREL CAGE INDUCTION INDEX OF PROTECTION (IP) COMPRESSOR 469.90 / 18.50 FILTER LENGTH SIZE INDOOR UNIT CASING OUTDOOR UNIT pc 6 mm/in 533 / 21.0 WIDTH mm/in 532 / 21.0 THICKNESS mm/in 50.8 / 2.00 MATERIAL ELECTRO GALVANIZED MILD STEEL COLOUR LIGHT GREY ELECTRO GALVANIZED MILD STEEL MATERIAL COLOUR LIGHT GREY 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 64 Components Data - Heatpump MODEL INDOOR FAN MDB300BR3 INDOOR UNIT OUTDOOR UNIT MMC100BR x 3 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.62 / 17.50 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 5 FIN PER INCH 12 BARE TUBE MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 12 WASHABLE VILEDON TYPE pc 6 LENGTH mm/in 533 / 21.0 WIDTH mm/in 532 / 21.0 mm/in 50.8 / 2.00 QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 459.99 / 18.11 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 469.90 / 18.50 FILTER SIZE THICKNESS INDOOR UNIT CASING OUTDOOR UNIT ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 65 Components Data - Heatpump MODEL MDB350BR3 INDOOR UNIT OUTDOOR UNIT MMC100BR x 1 INDOOR FAN QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 469.90 / 18.50 459.99 / 18.11 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR MMC125BR x 2 CENTRIFUGAL TYPE 1 QUANTITY IP54 INDEX OF PROTECTION (IP) TYPE PROPELLER QUANTITY OUTDOOR FAN MATERIAL DRIVE DIAMETER mm/in TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) TYPE COMPRESSOR OIL TYPE cm3 / fl.oz. OIL AMOUNT 1 ALUMINIUM ALUMINIUM DIRECT DIRECT 660.40 / 26 762.00 / 30 INDUCTION INDUCTION 1 1 IP54 IP54 SCROLL SCROLL SONTEX 200LT SONTEX 200LT 3253.1 / 110 3253.1 / 110 SEAMLESS COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 ALUMINIUM MATERIAL INDOOR COIL FIN THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 2.38 / 25.62 ROW 4 FIN PER INCH 12 MATERIAL TUBE BARE TUBE FIN INNER GROOVE DIAMETER mm/in 9.52 / ⅜ 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 0.36 / 0.014 ALUMINIUM ALUMINIUM THICKNESS mm/in 0.127 / 0.005 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 1.76 / 19.00 MATERIAL OUTDOOR COIL ROW 2 2 FIN PER INCH 12 18 WASHABLE VILEDON WASHABLE VILEDON TYPE QUANTITY AIR QUALITY PROPELLER 1 FILTER LENGTH SIZE INDOOR UNIT CASING OUTDOOR UNIT pc 6 6 mm/in 617 / 24.3 617 / 24.3 WIDTH mm/in 661 / 26.0 661 / 26.0 THICKNESS mm/in 50.8 / 2.00 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL MATERIAL COLOUR LIGHT GREY ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 66 Components Data - Heatpump MODEL INDOOR FAN MDB400BR4 INDOOR UNIT OUTDOOR UNIT MMC100BR x 4 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 ALUMINIUM MATERIAL INDOOR COIL FIN THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 2.38 / 25.62 ROW 4 FIN PER INCH 14 BARE TUBE MATERIAL TUBE FIN mm/in THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 9.52 / ALUMINIUM ROW 2 FIN PER INCH 12 WASHABLE VILEDON TYPE QUANTITY AIR QUALITY ⅜ DIAMETER MATERIAL OUTDOOR COIL 3253.1 / 110 SEAMLESS COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 563.88 / 22.20 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 591.82 / 23.30 FILTER LENGTH SIZE INDOOR UNIT CASING OUTDOOR UNIT pc 6 mm/in 668 / 26.3 WIDTH mm/in 661 / 26.0 THICKNESS mm/in 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 67 Components Data - Heatpump MODEL INDOOR FAN MDB500BR4 INDOOR UNIT OUTDOOR UNIT MMC125BR x 4 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 2.55 / 27.45 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 5 FIN PER INCH 12 INNER GROOVE MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.36 / 0.014 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 18 WASHABLE VILEDON TYPE pc 6 LENGTH mm/in 668 / 26.3 WIDTH mm/in 661 / 26.0 mm/in 50.8 / 2.00 QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS COPPER MATERIAL TUBE 762.00 / 30 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 563.88 / 22.20 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 591.82 / 23.30 FILTER SIZE THICKNESS INDOOR UNIT CASING OUTDOOR UNIT ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 68 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDSB200BR2 OUTDOOR UNIT MMC100BR x 2 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP20 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.20 / 12.92 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 4 FIN PER INCH 12 SEAMLESS BARE COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 12 WASHABLE VILEDON TYPE pc 3 LENGTH mm/in 542 / 19.4 WIDTH mm/in 738 / 29.1 mm/in 50.8 / 2.00 QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 381.00 / 15.00 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 394.97 / 15.55 FILTER SIZE THICKNESS INDOOR UNIT CASING OUTDOOR UNIT ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 69 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDSB250BR2 OUTDOOR UNIT MMC125BR x 2 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in THICKNESS mm/in FIN mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.48 / 16.01 ROW 4 FIN PER INCH 14 INNER GROOVE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.36 / 0.014 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 18 WASHABLE VILEDON TYPE QUANTITY AIR QUALITY ⅜ THICKNESS MATERIAL TUBE 9.52 / 0.35 / 0.013 ALUMINIUM MATERIAL INDOOR COIL 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 762.00 / 30 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 459.99 / 18.11 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 469.90 / 18.50 FILTER LENGTH SIZE INDOOR UNIT CASING OUTDOOR UNIT pc 6 mm/in 533 / 21.0 WIDTH mm/in 532 / 21.0 THICKNESS mm/in 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 70 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDSB300BR3 OUTDOOR UNIT MMC100BR x 3 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY INDEX OF PROTECTION (IP) IP54 TYPE PROPELLER QUANTITY 1 ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 TYPE SCROLL OIL TYPE SONTEX 200LT cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.62 / 17.50 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 5 FIN PER INCH 12 BARE TUBE MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 12 WASHABLE VILEDON TYPE pc 6 LENGTH mm/in 533 / 21.0 WIDTH mm/in 532 / 21.0 mm/in 50.8 / 2.00 QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 459.99 / 18.11 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 469.90 / 18.50 FILTER SIZE THICKNESS INDOOR UNIT CASING OUTDOOR UNIT ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR MATERIAL ELECTRO GALVANIZED MILD STEEL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 71 Components Data - Heatpump MODEL MDSB350BR3 INDOOR UNIT OUTDOOR UNIT MMC100BR x 1 INDOOR FAN QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 469.90 / 18.50 459.99 / 18.11 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR MMC125BR x 2 CENTRIFUGAL TYPE 1 QUANTITY IP54 INDEX OF PROTECTION (IP) TYPE PROPELLER QUANTITY OUTDOOR FAN MATERIAL DRIVE DIAMETER mm/in TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) TYPE COMPRESSOR OIL TYPE cm3 / fl.oz. OIL AMOUNT 1 ALUMINIUM ALUMINIUM DIRECT DIRECT 660.40 / 26 762.00 / 30 INDUCTION INDUCTION 1 1 IP54 IP54 SCROLL SCROLL SONTEX 200LT SONTEX 200LT 3253.1 / 110 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 ALUMINIUM MATERIAL INDOOR COIL FIN THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 2.38 / 25.62 ROW 4 FIN PER INCH 12 MATERIAL TUBE BARE TUBE FIN mm/in 9.52 / ⅜ 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 0.36 / 0.014 ALUMINIUM ALUMINIUM THICKNESS mm/in 0.127 / 0.005 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 1.76 / 19.00 ROW 2 2 FIN PER INCH 12 18 WASHABLE VILEDON WASHABLE VILEDON TYPE QUANTITY AIR QUALITY INNER GROOVE DIAMETER MATERIAL OUTDOOR COIL PROPELLER 1 FILTER LENGTH SIZE INDOOR UNIT CASING OUTDOOR UNIT pc 6 6 mm/in 617 / 24.3 617 / 24.3 WIDTH mm/in 661 / 26.0 661 / 26.0 THICKNESS mm/in 50.8 / 2.00 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL MATERIAL COLOUR LIGHT GREY ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 72 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDSB400BR4 OUTDOOR UNIT MMC100BR x 4 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 ALUMINIUM MATERIAL INDOOR COIL FIN THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 2.38 / 25.62 ROW 4 FIN PER INCH 14 BARE TUBE MATERIAL TUBE FIN mm/in THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 9.52 / ALUMINIUM ROW 2 FIN PER INCH 12 WASHABLE VILEDON TYPE QUANTITY AIR QUALITY ⅜ DIAMETER MATERIAL OUTDOOR COIL 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 660.40 / 26 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 563.88 / 22.20 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 591.82 / 23.30 FILTER LENGTH SIZE INDOOR UNIT CASING OUTDOOR UNIT pc 6 mm/in 668 / 26.3 WIDTH mm/in 661 / 26.0 THICKNESS mm/in 50.8 / 2.00 ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 73 Components Data - Heatpump MODEL INDOOR FAN INDOOR UNIT MDSB500BR4 OUTDOOR UNIT MMC125BR x 4 TYPE CENTRIFUGAL QUANTITY 1 MATERIAL ZINC COATED STEEL BELT DRIVEN DRIVE DIAMETER mm/in LENGTH mm/in 1 QUANTITY IP54 INDEX OF PROTECTION (IP) PROPELLER TYPE 1 QUANTITY ALUMINIUM OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER mm/in 1 IP54 SCROLL TYPE SONTEX 200LT OIL TYPE cm3 / fl.oz. OIL AMOUNT DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.35 / 0.013 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 2.55 / 27.45 ALUMINIUM MATERIAL INDOOR COIL FIN ROW 5 FIN PER INCH 12 INNER GROOVE MATERIAL TUBE DIAMETER mm/in 9.52 / ⅜ THICKNESS mm/in 0.36 / 0.014 THICKNESS mm/in 0.127 / 0.005 FACE AREA m2/ft2 1.76 / 19.00 ALUMINIUM MATERIAL OUTDOOR COIL FIN ROW 2 FIN PER INCH 18 WASHABLE VILEDON TYPE pc 6 LENGTH mm/in 668 / 26.3 WIDTH mm/in 661 / 26.0 mm/in 50.8 / 2.00 QUANTITY AIR QUALITY 3253.1 / 110 SEAMLESS PLAIN COPPER MATERIAL TUBE 762.00 / 30 INDUCTION TYPE OUTDOOR FAN QUANTITY MOTOR INDEX OF PROTECTION (IP) COMPRESSOR 563.88 / 22.20 SQUIRREL CAGE INDUCTION TYPE INDOOR FAN MOTOR 591.82 / 23.30 FILTER SIZE THICKNESS INDOOR UNIT CASING OUTDOOR UNIT ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR ELECTRO GALVANIZED MILD STEEL MATERIAL LIGHT GREY COLOUR 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 74 Safety Devices Data - Heatpump MODEL INDOOR UNIT MDB075BR OUTDOOR UNIT MMC075CR TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB100BR OUTDOOR UNIT MMC100BR TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 °C / °F 125 / 257 PHASE SEQUENCER OYLT DISCHARGE THERMOSTAT SETTING 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB125CR OUTDOOR UNIT MMC125BR TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB150BR2 OUTDOOR UNIT MMC075CR x 2 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 75 Safety Devices Data - Heatpump MODEL INDOOR UNIT MDB200BR2 OUTDOOR UNIT MMC100BR x 2 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi 3240536 / 470 2647587 / 384 TYPE SAFETY DEVICE LOW PRESSURE SWITCH AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB250BR2 OUTDOOR UNIT MMC125BR x 2 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi 3240536 / 470 2647587 / 384 TYPE SAFETY DEVICE LOW PRESSURE SWITCH AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 °C / °F 125 / 257 PHASE SEQUENCER OYLT DISCHARGE THERMOSTAT SETTING 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB300BR3 OUTDOOR UNIT MMC100BR x 3 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi 3240536 / 470 2647587 / 384 TYPE SAFETY DEVICE LOW PRESSURE SWITCH AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB350BR3 OUTDOOR UNIT TYPE HIGH PRESSURE SWITCH LOW PRESSURE SWITCH MMC125BR x 2 AUTO RESET AUTO RESET 3240536 / 470 OPEN Pa / psi 3240536 / 470 CLOSE Pa / psi 2647587 / 384 2647587 / 384 AUTO RESET AUTO RESET TYPE SAFETY DEVICE MMC100BR x 1 OPEN Pa / psi 124105.6 / 18 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 193053.2 / 28 PHASE SEQUENCER DISCHARGE THERMOSTAT SETTING °C / °F OYLT OYLT 125 / 257 125 / 257 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 76 Safety Devices Data - Heatpump MODEL INDOOR UNIT MDB400BR4 OUTDOOR UNIT MMC100BR x 4 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDB500BR4 OUTDOOR UNIT MMC125BR x 4 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 °C / °F 125 / 257 PHASE SEQUENCER DISCHARGE THERMOSTAT SETTING OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 77 Safety Devices Data - Heatpump MODEL INDOOR UNIT MDSB200BR2 OUTDOOR UNIT MMC100BR x 2 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi 3240536 / 470 2647587 / 384 TYPE SAFETY DEVICE LOW PRESSURE SWITCH AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDSB250BR2 OUTDOOR UNIT MMC125BR x 2 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi 3240536 / 470 2647587 / 384 TYPE SAFETY DEVICE LOW PRESSURE SWITCH AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 °C / °F 125 / 257 PHASE SEQUENCER OYLT DISCHARGE THERMOSTAT SETTING 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDSB300BR3 OUTDOOR UNIT MMC100BR x 3 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi 3240536 / 470 2647587 / 384 TYPE SAFETY DEVICE LOW PRESSURE SWITCH AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDSB350BR3 OUTDOOR UNIT TYPE HIGH PRESSURE SWITCH LOW PRESSURE SWITCH MMC125BR x 2 AUTO RESET AUTO RESET 3240536 / 470 OPEN Pa / psi 3240536 / 470 CLOSE Pa / psi 2647587 / 384 2647587 / 384 AUTO RESET AUTO RESET TYPE SAFETY DEVICE MMC100BR x 1 OPEN Pa / psi 124105.6 / 18 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 193053.2 / 28 PHASE SEQUENCER DISCHARGE THERMOSTAT SETTING °C / °F OYLT OYLT 125 / 257 125 / 257 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 78 Safety Devices Data - Heatpump MODEL INDOOR UNIT MDSB400BR4 OUTDOOR UNIT MMC100BR x 4 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 DISCHARGE THERMOSTAT SETTING °C / °F 125 / 257 PHASE SEQUENCER OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL INDOOR UNIT MDSB500BR4 OUTDOOR UNIT MMC125BR x 4 TYPE HIGH PRESSURE SWITCH AUTO RESET OPEN Pa / psi CLOSE Pa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH 3240536 / 470 2647587 / 384 AUTO RESET OPEN Pa / psi 124105.6 / 18 CLOSE Pa / psi 193053.2 / 28 °C / °F 125 / 257 PHASE SEQUENCER DISCHARGE THERMOSTAT SETTING OYLT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 79 Perf or mance Da ta erfor ormance Data Interpolation method can be used to get the total capacity, TC and sensible capacity, SC and power input, PI at those temperatures which are not stated out in the table. Extrapolation method are not allowed to be used to get the TC, SC and PI Example: Model: MDB075BR / MMC075BR Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Fan Speed: High Solution: Overall Based on the Performance table 1. Refer to the Indoor DB column, - 25°C is located between 24°C and 27°C for 16°CWB (Thus, Interpolation need to be applied) - 25°C is located between 24°C and 27°C for 19°CWB (Thus, Interpolation need to be applied) 2. Refer to the Indoor WB column, - 17°C is located between 16°CWB and 19°CWB for 25°CDB (Thus, Interpolation need to be applied) 3. Refer to the Outdoor DB column, - 37°C is located between 35°C and 40°C. (Thus, Interpolation need to be applied) Please follow the steps below in order to get the required capacity. 1st Step 2nd Step 3rd Step Interpolation of Indoor DB Interpolation of Indoor WB Interpolation of Outdoor DB Find TC, SC, PI for Find TC, SC, PI for Find TC, SC, PI for (a) Indoor: 25°C DB, 16°C WB (a) Indoor: 25°C DB, 17°C WB (a) Indoor: 25°C DB, 17°C WB Outdoor: 35°C DB Outdoor: 35°C DB (b) Indoor: 25°C DB, 19°C WB Outdoor: 35°C DB (b) Indoor: 25°C DB, 17°C WB Outdoor: 40°C DB (c) Indoor: 25°C DB, 16°C WB Outdoor: 40°C DB (d) Indoor: 25°C DB, 19°C WB Outdoor: 40°C DB 80 Outdoor: 37°C DB Details: 1st Step: To obtain the Total capacity and Sensible capacity and Power input for (a) Indoor Condition: 25°C DB, 16°C WB Outdoor Condition: 35°C DB Indoor WB °C Indoor DB °C 16 24 25 27 Outdoor DB ° C 35 TC (kW) SHC (kW) 19.75 x1 20.15 Total capacity, TC Interpolation Method: ⇒ 25°C - 24°C x1 - 19.75kW = 27°C - 24°C 20.15kW - 19.75kW ⇒ x1 = 19.88kW Sensible capacity, SHC Interpolation Method: ⇒ 25°C - 24°C y1 - 17.30kW = 27°C - 24°C 19.80kW - 17.30kW ⇒ y1 = 18.13kW Power Input, PI Interpolation Method: ⇒ 25°C - 24°C = 27°C - 24°C z1 - 8.31kW 8.35kW - 8.31kW ⇒ z1 = 8.32kW 81 17.30 y1 19.80 PI (kW) 8.31 z1 8.35 (b) Indoor Condition: 25°C DB, 16°C WB Outdoor Condition: 40°C DB Indoor WB °C Indoor DB °C 16 24 25 27 Outdoor DB ° C 40 TC (kW) SHC (kW) 17.77 x2 18.27 Total capacity, TC Interpolation Method: ⇒ 25°C - 24°C x2 - 17.77kW = 27°C - 24°C 18.27kW - 17.77kW ⇒ x2 = 17.94kW Sensible capacity, SHC Interpolation Method: ⇒ 25°C - 24°C y2 - 15.84kW = 27°C - 24°C 18.05kW - 15.84kW ⇒ y2 = 16.58kW Power Input, PI Interpolation Method: ⇒ 25°C - 24°C = 27°C - 24°C z2 - 8.99kW 9.04kW - 8.99kW ⇒ z2 = 9.01kW * Repeat process (a) and (b) in 1st step for the condition below: (c) Indoor Condition: 25°C DB, 19°C WB Outdoor Condition: 35°C DB ⇒ x3 = 21.62kW ⇒ y3 = 14.46kW ⇒ z3 = 8.49kW (c) Indoor Condition: 25°C DB, 19°C WB Outdoor Condition: 40°C DB ⇒ x4 = 19.47kW ⇒ y4 = 13.24kW ⇒ z4 = 9.17kW 82 15.84 y2 18.05 PI (kW) 8.99 z2 9.04 2nd Step: To obtain the Total capacity and Sensible capacity and Power Input for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 35°C DB Indoor DB °C Indoor WB °C 16 17 19 Outdoor DB ° C 35 TC (kW) SC (kW) 19.88 x5 21.62 25 Total capacity, TC Interpolation Method: ⇒ 17°C - 16°C x5 - 19.88kW = 19°C - 16°C 21.62kW - 19.88kW ⇒ x5 = 16.91kW Sensible capacity, SHC Interpolation Method: ⇒ 17°C - 16°C y5 - 18.13kW = 19°C - 16°C 14.46kW - 18.13kW ⇒ y5 = 17.73kW Power Input, PI Interpolation Method: ⇒ 17°C - 16°C 19°C - 16°C = z5 - 8.32kW 8.49kW - 8.32kW ⇒ z5 = 8.38kW 83 18.13 y5 14.46 PI (kW) 8.32 z5 8.49 (b) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 40°C DB Indoor DB °C Indoor WB °C 16 17 19 25 Outdoor DB ° C 40 TC (kW) SC (kW) 17.94 x6 19.47 Total capacity, TC Interpolation Method: ⇒ 17°C - 16°C x6 - 17.94kW = 19°C - 16°C 19.47kW - 17.94kW ⇒ x6 = 18.48kW Sensible capacity, SHC Interpolation Method: ⇒ 17°C - 16°C y6 - 16.58kW = 19°C - 16°C 13.24kW - 16.58kW ⇒ y6 = 15.47kW Power Input, PI Interpolation Method: ⇒ 17°C - 16°C 19°C - 16°C = z6 - 9.01kW 9.17kW - 9.01kW ⇒ z6 = 9.06kW 84 16.58 y6 13.24 PI (kW) 9.01 z6 9.17 3rd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 37°C DB Indoor DB °C Indoor WB °C 25 17 TC (kW) 35 SHC (kW) PI (kW) 20.46 16.91 8.38 Total capacity, TC Interpolation Method: ⇒ 37°C - 35°C x - 20.46kW = 40°C - 35°C 18.48kW - 20.46kW ⇒ x = 19.66kW Sensible capacity, SHC Interpolation Method: ⇒ 37°C - 35°C y - 16.91kW = 40°C - 35°C 15.47kW - 16.91kW ⇒ y = 16.33kW Power Input, PI Interpolation Method: ⇒ 37°C - 35°C 40°C - 35°C = z - 8.38kW 9.06kW - 8.38kW ⇒ z = 8.65kW 85 Outdoor DB ° C 37 TC SC PI (kW) (kW) (kW) x y z TC (kW) 40 SC (kW) PI (kW) 18.48 15.47 9.06 R22 MODELS (HEATPUMP) MODEL : MDB075BR / MMC075BR COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 2250 19°C 22°C 16°C 2500 19°C 22°C 16°C 2750 19°C 22°C EDB TC 21.43 21.52 21.59 22.45 23.55 23.61 23.70 23.84 25.84 25.87 25.94 26.02 21.88 22.00 22.15 23.30 24.03 24.12 24.23 24.61 26.33 26.40 26.50 26.59 22.27 22.41 22.73 24.05 24.43 24.55 24.68 25.40 26.75 26.84 26.97 27.10 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 14.92 17.77 20.45 22.45 14.09 16.46 20.09 23.84 13.24 16.36 19.07 21.71 15.52 18.50 21.44 23.30 14.65 17.14 21.03 24.61 13.75 17.08 19.97 22.83 15.94 18.99 22.14 24.05 15.33 17.94 22.11 25.40 14.38 17.89 21.01 24.06 PI 6.67 6.67 6.68 6.75 6.84 6.84 6.85 6.86 7.02 7.02 7.03 7.04 6.70 6.71 6.72 6.82 6.87 6.88 6.89 6.92 7.06 7.07 7.08 7.09 6.73 6.75 6.77 6.88 6.91 6.92 6.93 6.99 7.10 7.11 7.12 7.13 TC 20.75 20.84 20.94 21.89 22.82 22.87 22.95 23.16 25.02 25.06 25.13 25.21 21.18 21.30 21.49 22.70 23.27 23.36 23.45 23.98 25.49 25.56 25.66 25.75 21.54 21.69 22.10 23.41 23.64 23.77 23.87 24.75 25.89 25.98 26.10 26.29 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 14.59 17.40 20.07 21.89 13.78 16.12 19.72 23.16 12.95 16.04 18.73 21.37 15.19 18.12 20.98 22.70 14.34 16.80 20.66 23.98 13.46 16.74 19.62 22.48 15.57 18.61 21.77 23.41 15.01 17.59 21.72 24.75 14.09 17.54 20.65 23.61 PI 7.13 7.13 7.14 7.22 7.30 7.31 7.32 7.33 7.50 7.50 7.51 7.51 7.16 7.17 7.19 7.29 7.34 7.35 7.36 7.40 7.54 7.55 7.55 7.56 7.19 7.21 7.24 7.35 7.37 7.38 7.40 7.47 7.57 7.58 7.59 7.61 TC 20.03 20.12 20.23 21.28 22.03 22.09 22.16 22.48 24.17 24.21 24.28 24.35 20.43 20.55 20.82 22.05 22.45 22.54 22.63 23.31 24.61 24.68 24.77 24.88 20.77 20.91 21.45 22.74 22.80 22.92 23.05 24.05 24.98 25.08 25.19 25.46 30°C SHC 14.24 17.01 19.66 21.28 13.46 15.77 19.34 22.48 12.64 15.70 18.37 21.01 14.82 17.72 20.44 22.05 14.01 16.43 20.27 23.31 13.16 16.38 19.26 22.08 15.18 18.21 21.35 22.74 14.68 17.21 21.32 24.05 13.78 17.17 20.28 23.09 PI 7.66 7.67 7.68 7.77 7.84 7.85 7.86 7.88 8.04 8.05 8.06 8.06 7.69 7.70 7.73 7.84 7.88 7.89 7.90 7.96 8.09 8.09 8.10 8.11 7.73 7.74 7.79 7.91 7.91 7.92 7.94 8.03 8.12 8.13 8.14 8.17 TC 19.26 19.35 19.51 20.62 21.20 21.26 21.33 21.81 23.27 23.32 23.39 23.46 19.63 19.75 20.15 21.37 21.59 21.69 21.78 22.61 23.68 23.75 23.84 24.02 19.96 20.09 20.75 22.02 21.92 22.04 22.19 23.32 24.03 24.13 24.23 24.64 35°C SHC 13.87 16.59 19.15 20.62 13.12 15.39 18.94 21.81 12.33 15.34 18.00 20.64 14.42 17.30 19.80 21.37 13.66 16.05 19.86 22.61 12.84 16.01 18.88 21.61 14.76 17.78 20.75 22.02 14.32 16.81 20.86 23.32 13.47 16.79 19.89 22.49 PI 8.26 8.27 8.29 8.40 8.45 8.46 8.47 8.51 8.66 8.67 8.67 8.68 8.30 8.31 8.35 8.47 8.49 8.50 8.51 8.59 8.70 8.71 8.72 8.74 8.33 8.34 8.41 8.53 8.52 8.54 8.55 8.67 8.74 8.75 8.76 8.80 TC 17.33 17.42 17.66 18.74 19.10 19.17 19.23 19.83 20.99 21.04 21.10 21.19 17.67 17.77 18.27 19.40 19.44 19.54 19.64 20.55 21.35 21.42 21.50 21.77 17.95 18.07 18.81 19.98 19.73 19.85 20.05 21.18 21.65 21.75 21.84 22.40 40°C SHC 12.66 15.19 17.44 18.74 11.99 14.10 17.41 19.83 11.28 14.06 16.56 19.01 13.15 15.84 18.05 19.40 12.50 14.71 18.25 20.55 11.76 14.68 17.38 19.98 13.46 16.29 18.81 19.98 13.09 15.42 19.07 21.18 12.35 15.40 18.31 20.68 PI 8.94 8.95 8.98 9.10 9.13 9.14 9.15 9.22 9.35 9.35 9.36 9.37 8.98 8.99 9.04 9.17 9.17 9.18 9.20 9.30 9.39 9.40 9.41 9.44 9.01 9.02 9.10 9.24 9.20 9.22 9.24 9.37 9.43 9.44 9.45 9.52 TC 16.10 16.18 16.58 17.62 17.76 17.83 17.90 18.68 19.54 19.60 19.66 19.84 16.39 16.49 17.14 18.23 18.08 18.17 18.31 19.34 19.87 19.95 20.03 20.47 16.65 16.76 17.63 18.77 18.33 18.44 18.77 19.93 20.14 20.24 20.33 21.10 46°C SHC 11.98 14.43 16.38 17.62 11.38 13.41 16.65 18.68 10.72 13.40 15.84 18.12 12.43 15.06 16.98 18.23 11.87 14.00 17.36 19.34 11.19 14.00 16.64 19.05 12.72 15.50 17.63 18.77 12.40 14.69 18.01 19.93 11.75 14.69 17.55 19.64 PI 9.84 9.85 9.90 10.03 10.04 10.05 10.06 10.16 10.27 10.27 10.28 10.30 9.88 9.89 9.97 10.10 10.08 10.09 10.11 10.24 10.31 10.32 10.33 10.39 9.91 9.93 10.03 10.17 10.11 10.13 10.17 10.32 10.34 10.35 10.37 10.47 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 13.056 13.056 15.488 15.488 16.299 16.299 25.216 25.216 30.080 30.080 32.512 32.512 34.944 34.944 17 12.939 12.939 15.240 15.240 16.007 16.007 24.040 24.040 29.270 29.270 31.611 31.611 33.951 33.951 19 12.822 12.822 14.992 14.992 15.715 15.715 22.864 22.864 28.460 28.460 30.709 30.709 32.958 32.958 21 12.705 12.705 14.744 14.744 15.424 15.424 21.688 21.688 27.649 27.649 29.807 29.807 31.964 31.964 23 12.480 12.480 14.469 14.469 15.132 15.132 21.639 21.639 26.839 26.839 28.905 28.905 30.971 30.971 25 12.255 12.255 14.194 14.194 14.841 14.841 21.589 21.589 26.029 26.029 28.003 28.003 29.978 29.978 27 12.030 12.030 13.919 13.919 14.549 14.549 21.539 21.539 25.219 25.219 27.101 27.101 28.984 28.984 86 R22 MODELS (HEATPUMP) MODEL : MDB100BR / MMC100BR COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 2880 19°C 22°C 16°C 3200 19°C 22°C 16°C 3520 19°C 22°C EDB TC 28.61 28.73 28.83 29.98 31.44 31.52 31.64 31.83 34.49 34.54 34.64 34.74 29.22 29.37 29.57 31.11 32.08 32.20 32.35 32.85 35.16 35.24 35.38 35.50 29.73 29.93 30.35 32.11 32.62 32.78 32.95 33.92 35.72 35.84 36.01 36.19 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 19.65 23.40 26.93 29.98 18.56 21.68 26.46 31.83 17.44 21.55 25.12 28.60 20.44 24.36 28.24 31.11 19.29 22.58 27.70 32.85 18.11 22.49 26.30 30.07 20.99 25.02 29.16 32.11 20.19 23.63 29.12 33.92 18.94 23.56 27.67 31.69 PI 8.68 8.69 8.70 8.79 8.90 8.91 8.92 8.93 9.14 9.15 9.15 9.16 8.73 8.74 8.75 8.87 8.95 8.96 8.97 9.01 9.20 9.20 9.21 9.22 8.77 8.78 8.81 8.95 8.99 9.01 9.02 9.10 9.24 9.25 9.27 9.28 TC 27.71 27.82 27.95 29.22 30.46 30.54 30.64 30.92 33.40 33.46 33.56 33.66 28.28 28.43 28.70 30.31 31.07 31.18 31.31 32.01 34.03 34.12 34.26 34.38 28.76 28.95 29.50 31.26 31.56 31.73 31.88 33.04 34.56 34.69 34.85 35.10 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 19.21 22.91 26.43 29.22 18.16 21.24 25.98 30.92 17.05 21.13 24.67 28.15 20.00 23.87 27.64 30.31 18.88 22.13 27.21 32.01 17.73 22.04 25.85 29.61 20.51 24.51 28.68 31.26 19.77 23.16 28.61 33.04 18.56 23.10 27.20 31.10 PI 9.28 9.29 9.30 9.40 9.51 9.51 9.52 9.55 9.76 9.77 9.77 9.78 9.32 9.34 9.36 9.49 9.56 9.57 9.58 9.64 9.82 9.82 9.84 9.85 9.37 9.38 9.43 9.58 9.60 9.61 9.63 9.73 9.86 9.87 9.89 9.91 TC 26.74 26.86 27.01 28.41 29.42 29.50 29.59 30.02 32.27 32.33 32.42 32.51 27.27 27.43 27.80 29.45 29.97 30.10 30.22 31.13 32.86 32.95 33.08 33.22 27.73 27.92 28.63 30.36 30.44 30.61 30.78 32.12 33.35 33.48 33.63 34.00 30°C SHC 18.75 22.40 25.89 28.41 17.73 20.77 25.47 30.02 16.65 20.68 24.20 27.67 19.52 23.34 26.92 29.45 18.45 21.64 26.69 31.13 17.33 21.58 25.37 29.08 19.99 23.98 28.12 30.36 19.34 22.67 28.07 32.12 18.15 22.61 26.71 30.42 PI 9.97 9.98 9.99 10.12 10.21 10.22 10.23 10.26 10.47 10.48 10.49 10.50 10.02 10.03 10.06 10.21 10.26 10.27 10.28 10.37 10.53 10.54 10.55 10.56 10.06 10.08 10.14 10.30 10.30 10.32 10.33 10.46 10.57 10.59 10.60 10.64 TC 25.71 25.83 26.06 27.54 28.30 28.39 28.48 29.11 31.07 31.13 31.23 31.32 26.21 26.37 26.90 28.53 28.82 28.96 29.08 30.19 31.62 31.71 31.84 32.07 26.65 26.83 27.70 29.40 29.26 29.43 29.63 31.13 32.08 32.22 32.36 32.90 35°C SHC 18.27 21.85 25.22 27.54 17.28 20.27 24.94 29.11 16.24 20.20 23.71 27.18 18.99 22.78 26.08 28.53 18.00 21.14 26.16 30.19 16.91 21.09 24.87 28.46 19.44 23.42 27.48 29.40 18.86 22.15 27.47 31.13 17.74 22.11 26.19 29.62 PI 10.76 10.77 10.79 10.93 11.00 11.01 11.02 11.08 11.28 11.28 11.29 11.30 10.81 10.82 10.87 11.03 11.05 11.07 11.08 11.19 11.33 11.34 11.36 11.38 10.85 10.86 10.95 11.11 11.10 11.11 11.13 11.28 11.38 11.39 11.41 11.46 TC 23.14 23.26 23.59 25.02 25.50 25.59 25.68 26.48 28.03 28.09 28.18 28.29 23.59 23.73 24.40 25.90 25.95 26.08 26.22 27.44 28.50 28.60 28.71 29.07 23.97 24.12 25.11 26.68 26.34 26.50 26.77 28.28 28.91 29.04 29.16 29.91 40°C SHC 16.68 20.00 22.97 25.02 15.79 18.57 22.93 26.48 14.86 18.52 21.81 25.04 17.32 20.86 23.77 25.90 16.47 19.37 24.04 27.44 15.49 19.34 22.89 26.31 17.72 21.45 24.98 26.68 17.24 20.31 25.12 28.28 16.27 20.29 24.12 27.24 PI 11.64 11.65 11.69 11.84 11.89 11.90 11.92 12.00 12.17 12.18 12.19 12.20 11.69 11.70 11.77 11.94 11.94 11.96 11.97 12.11 12.23 12.24 12.25 12.29 11.73 11.75 11.85 12.02 11.98 12.00 12.03 12.20 12.27 12.29 12.30 12.39 TC 21.49 21.60 22.13 23.52 23.71 23.81 23.90 24.93 26.09 26.16 26.25 26.48 21.89 22.02 22.89 24.34 24.13 24.26 24.45 25.82 26.53 26.63 26.74 27.33 22.23 22.38 23.54 25.06 24.48 24.62 25.07 26.61 26.90 27.03 27.15 28.18 46°C SHC 15.77 19.01 21.57 23.52 14.99 17.66 21.93 24.93 14.11 17.64 20.87 23.86 16.37 19.84 22.36 24.34 15.64 18.45 22.87 25.82 14.74 18.44 21.92 25.09 16.75 20.42 23.54 25.06 16.33 19.35 23.72 26.61 15.48 19.35 23.12 25.87 PI 12.82 12.83 12.89 13.06 13.08 13.09 13.10 13.23 13.37 13.37 13.39 13.42 12.86 12.88 12.98 13.15 13.13 13.14 13.17 13.33 13.42 13.43 13.45 13.52 12.91 12.92 13.06 13.24 13.17 13.19 13.24 13.43 13.46 13.48 13.50 13.63 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 16.630 16.630 19.236 19.236 20.104 20.104 29.659 29.659 34.871 34.871 37.477 37.477 40.083 40.083 17 16.602 16.602 18.968 18.968 19.757 19.757 29.206 29.206 33.938 33.938 36.441 36.441 38.944 38.944 19 16.575 16.575 18.700 18.700 19.409 19.409 28.753 28.753 33.006 33.006 35.405 35.405 37.805 37.805 21 16.547 16.547 18.433 18.433 19.061 19.061 28.300 28.300 32.073 32.073 34.369 34.369 36.666 36.666 23 16.145 16.145 18.071 18.071 18.713 18.713 27.286 27.286 31.141 31.141 33.334 33.334 35.527 35.527 25 15.742 15.742 17.710 17.710 18.365 18.365 26.273 26.273 30.208 30.208 32.298 32.298 34.388 34.388 27 15.340 15.340 17.348 17.348 18.017 18.017 25.259 25.259 29.275 29.275 31.262 31.262 33.249 33.249 87 R22 MODELS (HEATPUMP) MODEL : MDB125CR / MMC125BR COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 3780 19°C 22°C 16°C 4200 19°C 22°C 16°C 4620 19°C 22°C EDB TC 33.60 33.73 33.85 35.19 36.91 37.01 37.15 37.37 40.50 40.56 40.67 40.79 34.30 34.48 34.72 36.52 37.66 37.81 37.98 38.57 41.28 41.38 41.54 41.68 34.91 35.14 35.63 37.70 38.29 38.49 38.69 39.82 41.94 42.08 42.28 42.49 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 24.96 29.73 33.85 35.19 23.58 27.55 33.62 37.37 22.15 27.39 31.91 36.34 25.97 30.95 34.72 36.52 24.51 28.69 35.19 38.57 23.01 28.58 33.42 38.21 26.67 31.79 35.63 37.70 25.65 30.02 37.00 39.82 24.07 29.93 35.16 40.26 PI 8.74 8.75 8.76 8.85 8.97 8.97 8.98 8.99 9.21 9.21 9.22 9.23 8.79 8.80 8.82 8.94 9.02 9.02 9.04 9.08 9.26 9.27 9.28 9.29 8.83 8.85 8.88 9.02 9.06 9.07 9.09 9.16 9.31 9.32 9.33 9.35 TC 32.53 32.66 32.82 34.31 35.77 35.85 35.98 36.30 39.22 39.28 39.40 39.51 33.20 33.38 33.69 35.58 36.47 36.61 36.77 37.59 39.96 40.06 40.22 40.36 33.77 33.99 34.64 36.70 37.06 37.26 37.43 38.79 40.58 40.72 40.91 41.21 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 24.41 29.11 32.82 34.31 23.07 26.98 33.01 36.30 21.67 26.84 31.34 35.76 25.41 30.32 33.69 35.58 23.99 28.11 34.57 37.59 22.52 28.01 32.84 37.62 26.05 31.15 34.64 36.70 25.13 29.43 36.35 38.79 23.58 29.35 34.56 39.52 PI 9.35 9.36 9.37 9.47 9.58 9.58 9.59 9.62 9.83 9.84 9.85 9.86 9.39 9.41 9.43 9.56 9.63 9.64 9.65 9.71 9.89 9.90 9.91 9.92 9.43 9.45 9.50 9.65 9.67 9.69 9.70 9.80 9.93 9.95 9.96 9.98 TC 31.40 31.53 31.72 33.35 34.54 34.63 34.74 35.24 37.89 37.96 38.07 38.17 32.02 32.21 32.64 34.57 35.19 35.34 35.48 36.55 38.58 38.69 38.84 39.00 32.56 32.78 33.62 35.64 35.74 35.94 36.14 37.71 39.15 39.31 39.49 39.92 30°C SHC 23.83 28.46 31.72 33.35 22.52 26.39 32.37 35.24 21.16 26.28 30.75 35.16 24.81 29.65 32.64 34.57 23.44 27.50 33.91 36.55 22.02 27.42 32.23 36.95 25.40 30.47 33.62 35.64 24.57 28.80 35.67 37.71 23.06 28.73 33.93 38.65 PI 10.04 10.05 10.07 10.19 10.28 10.29 10.30 10.34 10.55 10.55 10.56 10.57 10.09 10.11 10.14 10.29 10.33 10.35 10.36 10.44 10.60 10.61 10.63 10.64 10.13 10.15 10.21 10.37 10.38 10.39 10.41 10.54 10.65 10.66 10.68 10.72 TC 30.19 30.33 30.59 32.33 33.23 33.33 33.43 34.18 36.48 36.55 36.67 36.77 30.77 30.96 31.58 33.50 33.84 34.00 34.15 35.44 37.12 37.23 37.38 37.65 31.29 31.50 32.52 34.52 34.36 34.55 34.79 36.55 37.66 37.83 37.99 38.63 35°C SHC 23.21 27.77 30.59 32.33 21.95 25.76 31.69 34.18 20.63 25.67 30.13 34.54 24.13 28.94 31.58 33.50 22.87 26.86 33.24 35.44 21.48 26.79 31.60 36.17 24.70 29.76 32.52 34.52 23.97 28.14 34.79 36.55 22.54 28.09 33.28 37.64 PI 10.84 10.85 10.87 11.01 11.08 11.09 11.11 11.17 11.36 11.36 11.38 11.39 10.89 10.90 10.95 11.11 11.13 11.15 11.16 11.27 11.41 11.42 11.44 11.46 10.93 10.94 11.03 11.19 11.18 11.20 11.22 11.37 11.46 11.47 11.49 11.55 TC 27.16 27.31 27.69 29.37 29.94 30.04 30.15 31.08 32.91 32.97 33.08 33.21 27.69 27.86 28.64 30.41 30.47 30.62 30.78 32.21 33.47 33.58 33.71 34.13 28.14 28.32 29.48 31.33 30.93 31.11 31.44 33.21 33.94 34.09 34.24 35.11 40°C SHC 21.19 25.41 27.69 29.37 20.06 23.59 29.14 31.08 18.88 23.53 27.71 31.81 22.01 26.51 28.64 30.41 20.92 24.61 30.55 32.21 19.68 24.57 29.08 33.43 22.52 27.26 29.48 31.33 21.90 25.80 31.44 33.21 20.67 25.78 30.65 34.61 PI 11.73 11.74 11.77 11.93 11.98 11.99 12.00 12.09 12.26 12.27 12.28 12.29 11.77 11.79 11.86 12.03 12.03 12.04 12.06 12.20 12.32 12.33 12.34 12.38 11.81 11.83 11.94 12.11 12.07 12.09 12.12 12.29 12.36 12.38 12.39 12.48 TC 25.23 25.36 25.99 27.62 27.83 27.95 28.06 29.27 30.64 30.72 30.82 31.09 25.70 25.85 26.87 28.58 28.33 28.48 28.71 30.32 31.15 31.27 31.40 32.09 26.10 26.28 27.64 29.42 28.74 28.91 29.43 31.24 31.58 31.74 31.87 33.08 46°C SHC 20.04 24.15 25.99 27.62 19.04 22.44 27.86 29.27 17.93 22.42 26.51 30.32 20.80 25.20 26.87 28.58 19.87 23.44 28.71 30.32 18.72 23.43 27.85 31.88 21.29 25.95 27.64 29.42 20.75 24.58 29.43 31.24 19.67 24.59 29.37 32.86 PI 12.91 12.92 12.99 13.15 13.17 13.18 13.20 13.32 13.47 13.47 13.48 13.51 12.96 12.97 13.08 13.25 13.22 13.24 13.26 13.43 13.52 13.53 13.55 13.62 13.00 13.02 13.15 13.34 13.27 13.28 13.34 13.53 13.56 13.58 13.60 13.73 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 22.109 22.109 25.583 25.583 26.741 26.741 39.477 39.477 46.424 46.424 49.898 49.898 53.371 53.371 17 22.071 22.071 25.226 25.226 26.278 26.278 38.041 38.041 45.182 45.182 48.518 48.518 51.855 51.855 19 22.032 22.032 24.869 24.869 25.815 25.815 36.606 36.606 43.941 43.941 47.139 47.139 50.338 50.338 21 21.993 21.993 24.512 24.512 25.352 25.352 35.170 35.170 42.699 42.699 45.760 45.760 48.821 48.821 23 21.460 21.460 24.032 24.032 24.889 24.889 34.697 34.697 41.457 41.457 44.381 44.381 47.304 47.304 25 20.927 20.927 23.551 23.551 24.426 24.426 34.223 34.223 40.215 40.215 43.002 43.002 45.788 45.788 27 20.394 20.394 23.071 23.071 23.963 23.963 33.750 33.750 38.973 38.973 41.622 41.622 44.271 44.271 88 R22 MODELS (HEATPUMP) MODEL : MDB150BR2 / MMC075CR x 2 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 4140 19°C 22°C 16°C 4600 19°C 22°C 16°C 5060 19°C 22°C EDB TC 42.86 43.03 43.19 44.90 47.09 47.22 47.40 47.67 51.67 51.74 51.89 52.04 43.77 43.99 44.30 46.60 48.05 48.24 48.46 49.21 52.67 52.79 53.00 53.18 44.54 44.83 45.46 48.09 48.86 49.10 49.36 50.81 53.50 53.68 53.94 54.21 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 29.83 35.53 40.90 44.90 28.18 32.92 40.17 47.67 26.48 32.73 38.14 43.43 31.03 36.99 42.88 46.60 29.29 34.29 42.06 49.21 27.50 34.15 39.94 45.66 31.88 37.99 44.27 48.09 30.65 35.88 44.22 50.81 28.77 35.78 42.01 48.12 PI 13.31 13.33 13.34 13.47 13.65 13.66 13.67 13.69 14.02 14.02 14.04 14.05 13.38 13.40 13.42 13.61 13.72 13.74 13.76 13.82 14.10 14.11 14.13 14.15 13.44 13.47 13.51 13.73 13.79 13.81 13.83 13.95 14.17 14.19 14.21 14.23 TC 41.51 41.67 41.87 43.77 45.63 45.74 45.90 46.31 50.04 50.12 50.27 50.41 42.36 42.59 42.99 45.40 46.53 46.71 46.91 47.96 50.98 51.11 51.32 51.49 43.08 43.37 44.19 46.82 47.28 47.53 47.75 49.49 51.77 51.96 52.20 52.58 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 29.17 34.79 40.14 43.77 27.57 32.25 39.45 46.31 25.89 32.08 37.46 42.74 30.37 36.24 41.96 45.40 28.68 33.60 41.31 47.96 26.92 33.47 39.25 44.96 31.14 37.22 43.55 46.82 30.03 35.17 43.45 49.49 28.18 35.07 41.30 47.23 PI 14.23 14.24 14.26 14.42 14.58 14.59 14.60 14.64 14.97 14.97 14.99 15.00 14.30 14.32 14.35 14.56 14.65 14.67 14.69 14.78 15.05 15.06 15.08 15.10 14.36 14.39 14.46 14.68 14.72 14.74 14.77 14.92 15.12 15.14 15.16 15.20 TC 40.06 40.23 40.47 42.55 44.06 44.18 44.33 44.96 48.34 48.43 48.57 48.70 40.85 41.10 41.64 44.11 44.90 45.09 45.27 46.63 49.22 49.36 49.55 49.75 41.54 41.83 42.89 45.48 45.60 45.85 46.11 48.11 49.95 50.16 50.38 50.93 30°C SHC 28.48 34.01 39.31 42.55 26.92 31.54 38.68 44.96 25.29 31.40 36.75 42.02 29.64 35.44 40.87 44.11 28.02 32.87 40.53 46.63 26.31 32.76 38.52 44.16 30.35 36.42 42.70 45.48 29.36 34.42 42.63 48.11 27.56 34.34 40.55 46.19 PI 15.29 15.30 15.32 15.51 15.65 15.66 15.68 15.74 16.06 16.07 16.08 16.10 15.36 15.38 15.43 15.66 15.73 15.75 15.77 15.90 16.14 16.16 16.18 16.20 15.42 15.45 15.55 15.79 15.80 15.82 15.85 16.04 16.21 16.23 16.26 16.31 TC 38.51 38.69 39.03 41.25 42.40 42.53 42.66 43.61 46.55 46.64 46.78 46.92 39.26 39.50 40.30 42.74 43.17 43.38 43.57 45.22 47.36 47.50 47.69 48.03 39.92 40.18 41.50 44.04 43.83 44.08 44.39 46.63 48.05 48.26 48.47 49.28 35°C SHC 27.74 33.18 38.30 41.25 26.23 30.78 37.88 43.61 24.66 30.68 36.00 41.27 28.84 34.59 39.60 42.74 27.33 32.10 39.72 45.22 25.68 32.02 37.76 43.22 29.52 35.56 41.50 44.04 28.64 33.63 41.71 46.63 26.94 33.57 39.77 44.98 PI 16.50 16.52 16.55 16.76 16.87 16.89 16.90 17.00 17.29 17.30 17.32 17.33 16.57 16.59 16.67 16.91 16.95 16.97 16.99 17.16 17.38 17.39 17.41 17.45 16.63 16.66 16.79 17.04 17.02 17.04 17.07 17.30 17.45 17.47 17.49 17.58 TC 34.66 34.84 35.33 37.47 38.20 38.33 38.46 39.66 41.98 42.07 42.21 42.37 35.33 35.55 36.54 38.80 38.88 39.07 39.27 41.10 42.70 42.84 43.01 43.54 35.90 36.13 37.61 39.97 39.46 39.69 40.11 42.36 43.31 43.50 43.68 44.80 40°C SHC 25.32 30.37 34.87 37.47 23.98 28.19 34.82 39.66 22.56 28.12 33.12 38.02 26.30 31.68 36.09 38.80 25.00 29.41 36.51 41.10 23.52 29.37 34.75 39.96 26.91 32.58 37.61 39.97 26.17 30.83 38.14 42.36 24.70 30.81 36.62 41.36 PI 17.85 17.87 17.92 18.16 18.24 18.25 18.27 18.40 18.67 18.68 18.69 18.71 17.92 17.95 18.06 18.31 18.31 18.33 18.36 18.57 18.75 18.76 18.79 18.85 17.98 18.01 18.17 18.44 18.38 18.41 18.45 18.71 18.82 18.84 18.87 19.00 TC 32.19 32.36 33.16 35.23 35.51 35.66 35.81 37.35 39.09 39.19 39.33 39.67 32.79 32.98 34.28 36.46 36.15 36.34 36.63 38.68 39.74 39.90 40.06 40.94 33.30 33.53 35.27 37.54 36.67 36.88 37.55 39.85 40.29 40.49 40.67 42.21 46°C SHC 23.95 28.86 32.75 35.23 22.75 26.82 33.29 37.35 21.43 26.79 31.68 36.24 24.86 30.12 33.96 36.46 23.75 28.01 34.72 38.68 22.38 28.00 33.28 38.10 25.44 31.01 35.27 37.54 24.80 29.38 36.01 39.85 23.50 29.39 35.10 39.28 PI 19.65 19.67 19.77 20.02 20.05 20.07 20.09 20.28 20.50 20.51 20.53 20.57 19.72 19.75 19.90 20.17 20.13 20.15 20.19 20.45 20.58 20.60 20.62 20.73 19.79 19.82 20.02 20.30 20.19 20.22 20.31 20.59 20.64 20.67 20.70 20.90 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 26.112 26.112 30.976 30.976 32.597 32.597 50.432 50.432 60.161 60.161 65.025 65.025 69.889 69.889 17 25.878 25.878 30.480 30.480 32.014 32.014 48.080 48.080 58.540 58.540 63.221 63.221 67.902 67.902 19 25.644 25.644 29.984 29.984 31.431 31.431 45.728 45.728 56.919 56.919 61.417 61.417 65.915 65.915 21 25.410 25.410 29.488 29.488 30.848 30.848 43.376 43.376 55.299 55.299 59.614 59.614 63.929 63.929 23 24.960 24.960 28.938 28.938 30.264 30.264 43.277 43.277 53.678 53.678 57.810 57.810 61.942 61.942 25 24.510 24.510 28.388 28.388 29.681 29.681 43.178 43.178 52.058 52.058 56.006 56.006 59.955 59.955 27 24.060 24.060 27.838 27.838 29.098 29.098 43.079 43.079 50.437 50.437 54.203 54.203 57.969 57.969 89 R22 MODELS (HEATPUMP) MODEL : MDB200BR2 / MMC100BR x 2 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 5760 19°C 22°C 16°C 6400 19°C 22°C 16°C 7040 19°C 22°C EDB TC 57.23 57.45 57.66 59.95 62.88 63.04 63.28 63.65 68.99 69.08 69.28 69.47 58.43 58.74 59.15 62.21 64.16 64.40 64.69 65.71 70.32 70.49 70.76 71.00 59.47 59.85 60.69 64.21 65.23 65.56 65.90 67.84 71.44 71.67 72.01 72.37 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 39.29 46.80 53.87 59.95 37.12 43.36 52.91 63.65 34.87 43.11 50.23 57.20 40.87 48.72 56.48 62.21 38.58 45.16 55.39 65.71 36.22 44.98 52.61 60.14 41.98 50.03 58.31 64.21 40.38 47.26 58.24 67.84 37.89 47.12 55.34 63.37 PI 16.68 16.70 16.72 16.88 17.10 17.11 17.13 17.16 17.56 17.57 17.59 17.60 16.77 16.79 16.82 17.05 17.20 17.21 17.24 17.31 17.67 17.68 17.70 17.72 16.85 16.87 16.93 17.20 17.28 17.30 17.33 17.48 17.76 17.78 17.80 17.83 TC 55.42 55.64 55.90 58.44 60.92 61.08 61.29 61.83 66.81 66.91 67.11 67.31 56.56 56.87 57.39 60.61 62.13 62.37 62.63 64.03 68.06 68.24 68.52 68.75 57.52 57.91 59.00 62.51 63.13 63.46 63.75 66.08 69.12 69.37 69.69 70.20 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 38.42 45.83 52.87 58.44 36.31 42.47 51.95 61.83 34.10 42.25 49.33 56.29 40.00 47.73 55.27 60.61 37.77 44.25 54.41 64.03 35.45 44.08 51.69 59.22 41.01 49.03 57.36 62.51 39.55 46.33 57.22 66.08 37.11 46.19 54.39 62.20 PI 17.83 17.85 17.87 18.07 18.27 18.28 18.30 18.34 18.75 18.76 18.78 18.80 17.92 17.94 17.98 18.24 18.36 18.38 18.41 18.52 18.86 18.88 18.90 18.92 18.00 18.03 18.11 18.40 18.45 18.47 18.50 18.69 18.95 18.97 19.00 19.04 TC 53.49 53.71 54.03 56.81 58.83 58.99 59.18 60.03 64.54 64.66 64.85 65.02 54.54 54.87 55.60 58.89 59.95 60.20 60.44 62.26 65.72 65.90 66.15 66.43 55.46 55.85 57.26 60.72 60.89 61.21 61.56 64.23 66.69 66.96 67.26 68.00 30°C SHC 37.51 44.80 51.78 56.81 35.45 41.53 50.95 60.03 33.31 41.36 48.40 55.34 39.04 46.68 53.84 58.89 36.90 43.29 53.38 62.26 34.65 43.15 50.73 58.16 39.98 47.96 56.24 60.72 38.67 45.33 56.15 64.23 36.30 45.23 53.41 60.83 PI 19.16 19.18 19.20 19.44 19.61 19.63 19.65 19.72 20.12 20.13 20.15 20.17 19.25 19.27 19.34 19.62 19.71 19.73 19.76 19.92 20.23 20.24 20.27 20.30 19.33 19.36 19.48 19.78 19.79 19.83 19.86 20.09 20.32 20.34 20.37 20.44 TC 51.42 51.66 52.11 55.07 56.61 56.78 56.95 58.23 62.15 62.27 62.46 62.64 52.41 52.74 53.80 57.06 57.64 57.91 58.17 60.37 63.23 63.43 63.67 64.13 53.29 53.65 55.40 58.80 58.52 58.86 59.26 62.26 64.16 64.43 64.71 65.80 35°C SHC 36.53 43.71 50.44 55.07 34.55 40.54 49.89 58.23 32.48 40.40 47.42 54.36 37.98 45.56 52.16 57.06 35.99 42.28 52.32 60.37 33.82 42.18 49.73 56.93 38.88 46.84 54.96 58.80 37.73 44.29 54.94 62.26 35.48 44.22 52.39 59.25 PI 20.67 20.69 20.74 21.00 21.14 21.16 21.18 21.30 21.67 21.68 21.70 21.72 20.76 20.79 20.89 21.19 21.24 21.26 21.29 21.50 21.77 21.79 21.82 21.86 20.84 20.88 21.03 21.35 21.32 21.35 21.39 21.68 21.86 21.89 21.92 22.03 TC 46.27 46.52 47.17 50.03 51.00 51.18 51.35 52.95 56.05 56.17 56.35 56.57 47.17 47.46 48.79 51.80 51.91 52.17 52.44 54.87 57.01 57.19 57.42 58.13 47.93 48.24 50.22 53.36 52.69 52.99 53.55 56.56 57.82 58.08 58.32 59.81 40°C SHC 33.35 40.00 45.93 50.03 31.58 37.13 45.86 52.95 29.72 37.04 43.62 50.08 34.64 41.72 47.54 51.80 32.93 38.74 48.09 54.87 30.97 38.68 45.77 52.62 35.45 42.91 49.97 53.36 34.47 40.61 50.23 56.56 32.53 40.57 48.24 54.48 PI 22.37 22.39 22.46 22.75 22.85 22.87 22.89 23.06 23.39 23.40 23.42 23.45 22.46 22.49 22.62 22.94 22.95 22.97 23.00 23.27 23.49 23.51 23.54 23.62 22.53 22.57 22.77 23.10 23.03 23.06 23.12 23.45 23.58 23.61 23.64 23.81 TC 42.98 43.20 44.27 47.04 47.41 47.62 47.81 49.87 52.19 52.33 52.51 52.97 43.78 44.03 45.77 48.68 48.27 48.51 48.90 51.65 53.06 53.27 53.48 54.66 44.46 44.77 47.09 50.12 48.95 49.25 50.13 53.21 53.79 54.06 54.30 56.35 46°C SHC 31.55 38.01 43.14 47.04 29.97 35.32 43.85 49.87 28.23 35.29 41.73 47.73 32.74 39.67 44.73 48.68 31.28 36.89 45.74 51.65 29.47 36.87 43.84 50.18 33.50 40.84 47.08 50.12 32.66 38.69 47.43 53.21 30.96 38.71 46.23 51.73 PI 24.63 24.65 24.77 25.09 25.13 25.15 25.17 25.41 25.68 25.70 25.72 25.78 24.72 24.75 24.94 25.27 25.22 25.25 25.30 25.62 25.78 25.81 25.84 25.98 24.80 24.83 25.09 25.44 25.30 25.34 25.44 25.81 25.87 25.90 25.94 26.18 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 33.260 33.260 38.472 38.472 40.209 40.209 59.319 59.319 69.742 69.742 74.954 74.954 80.166 80.166 17 33.205 33.205 37.936 37.936 39.513 39.513 58.413 58.413 67.877 67.877 72.882 72.882 77.888 77.888 19 33.150 33.150 37.401 37.401 38.818 38.818 57.506 57.506 66.012 66.012 70.811 70.811 75.610 75.610 21 33.095 33.095 36.865 36.865 38.122 38.122 56.600 56.600 64.146 64.146 68.739 68.739 73.331 73.331 23 32.290 32.290 36.142 36.142 37.426 37.426 54.573 54.573 62.281 62.281 66.667 66.667 71.053 71.053 25 31.485 31.485 35.419 35.419 36.731 36.731 52.545 52.545 60.416 60.416 64.595 64.595 68.775 68.775 27 30.679 30.679 34.696 34.696 36.035 36.035 50.517 50.517 58.550 58.550 62.524 62.524 66.497 66.497 90 R22 MODELS (HEATPUMP) MODEL : MDB250BR2 / MMC125BR x 2 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 7200 19°C 22°C 16°C 8000 19°C 22°C 16°C 8800 19°C 22°C EDB TC 67.19 67.45 67.70 70.39 73.82 74.01 74.30 74.73 81.00 81.11 81.34 81.57 68.61 68.96 69.44 73.04 75.33 75.61 75.96 77.15 82.56 82.76 83.07 83.36 69.82 70.27 71.26 75.39 76.59 76.97 77.38 79.65 83.87 84.15 84.55 84.97 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 49.92 59.46 67.70 70.39 47.16 55.09 67.23 74.73 44.31 54.77 63.82 72.67 51.93 61.90 69.44 73.04 49.02 57.38 70.38 77.15 46.02 57.15 66.84 76.42 53.34 63.57 71.26 75.39 51.30 60.05 74.00 79.65 48.14 59.87 70.31 80.52 PI 18.41 18.43 18.45 18.63 18.87 18.88 18.90 18.93 19.38 19.39 19.41 19.43 18.51 18.53 18.56 18.82 18.98 19.00 19.02 19.10 19.50 19.51 19.54 19.56 18.59 18.62 18.69 18.98 19.07 19.09 19.12 19.29 19.59 19.62 19.65 19.68 TC 65.06 65.33 65.64 68.61 71.53 71.71 71.96 72.60 78.44 78.56 78.80 79.03 66.41 66.77 67.38 71.16 72.95 73.22 73.53 75.17 79.91 80.12 80.44 80.72 67.54 67.99 69.27 73.40 74.12 74.51 74.85 77.58 81.16 81.45 81.82 82.43 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 48.82 58.23 65.64 68.61 46.14 53.97 66.01 72.60 43.33 53.68 62.68 71.53 50.82 60.65 67.38 71.16 47.99 56.22 69.14 75.17 45.04 56.01 65.68 75.24 52.11 62.29 69.27 73.40 50.25 58.86 72.71 77.58 47.15 58.69 69.11 79.03 PI 19.67 19.69 19.72 19.94 20.16 20.17 20.19 20.24 20.70 20.71 20.73 20.74 19.77 19.80 19.85 20.13 20.26 20.29 20.32 20.44 20.81 20.83 20.86 20.88 19.86 19.89 19.99 20.30 20.36 20.39 20.42 20.63 20.91 20.94 20.97 21.01 TC 62.80 63.07 63.43 66.70 69.07 69.26 69.48 70.48 75.77 75.91 76.14 76.33 64.04 64.42 65.28 69.14 70.38 70.68 70.96 73.09 77.16 77.37 77.67 77.99 65.12 65.57 67.23 71.29 71.49 71.87 72.28 75.41 78.30 78.62 78.97 79.83 30°C SHC 47.66 56.92 63.43 66.70 45.05 52.77 64.73 70.48 42.32 52.55 61.50 70.32 49.61 59.31 65.28 69.14 46.89 55.00 67.83 73.09 44.03 54.83 64.46 73.90 50.79 60.94 67.23 71.29 49.13 57.60 71.34 75.41 46.12 57.46 67.86 77.29 PI 21.14 21.16 21.19 21.45 21.64 21.66 21.69 21.76 22.21 22.22 22.24 22.26 21.24 21.27 21.34 21.65 21.75 21.78 21.81 21.98 22.32 22.34 22.37 22.40 21.33 21.36 21.50 21.83 21.84 21.88 21.91 22.18 22.42 22.45 22.48 22.55 TC 60.37 60.66 61.18 64.66 66.46 66.67 66.87 68.36 72.97 73.11 73.33 73.55 61.54 61.92 63.17 66.99 67.68 68.00 68.29 70.88 74.24 74.47 74.76 75.29 62.57 62.99 65.05 69.04 68.71 69.11 69.58 73.10 75.33 75.65 75.98 77.25 35°C SHC 46.41 55.53 61.18 64.66 43.90 51.51 63.39 68.36 41.27 51.34 60.25 69.07 48.26 57.89 63.17 66.99 45.73 53.72 66.48 70.88 42.97 53.59 63.19 72.33 49.40 59.51 65.05 69.04 47.93 56.28 69.58 73.10 45.08 56.18 66.56 75.28 PI 22.81 22.84 22.88 23.18 23.33 23.35 23.38 23.50 23.91 23.92 23.95 23.97 22.91 22.94 23.05 23.38 23.44 23.47 23.50 23.72 24.03 24.05 24.08 24.12 23.00 23.04 23.21 23.56 23.53 23.57 23.61 23.92 24.12 24.15 24.19 24.31 TC 54.33 54.62 55.38 58.74 59.87 60.09 60.29 62.17 65.81 65.95 66.16 66.42 55.38 55.72 57.29 60.82 60.94 61.25 61.57 64.43 66.93 67.15 67.42 68.25 56.28 56.64 58.96 62.65 61.86 62.22 62.87 66.41 67.88 68.19 68.48 70.23 40°C SHC 42.37 50.83 55.38 58.74 40.13 47.18 58.27 62.17 37.76 47.06 55.42 63.63 44.01 53.02 57.29 60.82 41.84 49.22 61.10 64.43 39.35 49.15 58.16 66.86 45.04 54.52 58.96 62.65 43.80 51.60 62.87 66.41 41.34 51.55 61.29 69.22 PI 24.68 24.71 24.78 25.11 25.22 25.24 25.26 25.45 25.81 25.82 25.85 25.88 24.78 24.82 24.97 25.31 25.32 25.35 25.39 25.68 25.93 25.95 25.98 26.06 24.87 24.91 25.13 25.50 25.41 25.45 25.52 25.88 26.02 26.05 26.09 26.27 TC 50.47 50.72 51.97 55.23 55.67 55.91 56.13 58.55 61.27 61.44 61.65 62.19 51.40 51.70 53.74 57.16 56.67 56.96 57.42 60.64 62.30 62.54 62.79 64.17 52.20 52.56 55.28 58.84 57.48 57.82 58.86 62.47 63.16 63.47 63.75 66.16 46°C SHC 40.08 48.30 51.97 55.23 38.08 44.88 55.71 58.55 35.86 44.84 53.02 60.64 41.60 50.41 53.74 57.16 39.74 46.87 57.42 60.64 37.45 46.85 55.70 63.75 42.57 51.89 55.28 58.84 41.50 49.16 58.86 62.47 39.33 49.18 58.74 65.73 PI 27.18 27.21 27.34 27.69 27.73 27.75 27.78 28.05 28.34 28.36 28.39 28.45 27.27 27.31 27.52 27.89 27.83 27.86 27.92 28.27 28.45 28.48 28.51 28.67 27.37 27.40 27.69 28.08 27.92 27.96 28.08 28.48 28.55 28.58 28.62 28.89 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. 4. Unit is able to operate at ambient from 0°C to 52°C without pressure trip. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 44.219 44.219 51.166 51.166 53.482 53.482 78.954 78.954 92.848 92.848 99.795 99.795 106.743 106.743 17 44.141 44.141 50.452 50.452 52.556 52.556 76.083 76.083 90.365 90.365 97.037 97.037 103.709 103.709 19 44.064 44.064 49.738 49.738 51.630 51.630 73.211 73.211 87.881 87.881 94.278 94.278 100.676 100.676 21 43.986 43.986 49.025 49.025 50.704 50.704 70.340 70.340 85.398 85.398 91.520 91.520 97.642 97.642 23 42.920 42.920 48.064 48.064 49.778 49.778 69.393 69.393 82.914 82.914 88.762 88.762 94.609 94.609 25 41.854 41.854 47.103 47.103 48.853 48.853 68.446 68.446 80.430 80.430 86.003 86.003 91.576 91.576 27 40.787 40.787 46.142 46.142 47.927 47.927 67.500 67.500 77.947 77.947 83.245 83.245 88.542 88.542 91 R22 MODELS (HEATPUMP) MODEL : MDB300BR3 / MMC100CR x 3 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 8100 19°C 22°C 16°C 9000 19°C 22°C 16°C 9900 19°C 22°C EDB TC 85.84 86.18 86.50 89.93 94.32 94.56 94.92 95.47 103.48 103.63 103.92 104.21 87.65 88.11 88.72 93.32 96.24 96.60 97.04 98.56 105.48 105.73 106.14 106.50 89.20 89.78 91.04 96.32 97.84 98.34 98.86 101.76 107.15 107.51 108.02 108.56 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 58.94 70.20 80.80 89.93 55.68 65.04 79.37 95.47 52.31 64.66 75.35 85.80 61.31 73.08 84.73 93.32 57.87 67.74 83.09 98.56 54.33 67.47 78.91 90.22 62.98 75.05 87.47 96.32 60.56 70.89 87.36 101.76 56.83 70.68 83.01 95.06 PI 24.95 24.97 25.00 25.25 25.57 25.59 25.62 25.66 26.27 26.28 26.30 26.33 25.08 25.12 25.16 25.50 25.72 25.74 25.78 25.89 26.42 26.44 26.48 26.51 25.19 25.24 25.32 25.72 25.84 25.88 25.92 26.14 26.55 26.58 26.63 26.67 TC 83.13 83.46 83.86 87.66 91.39 91.61 91.93 92.75 100.21 100.37 100.67 100.97 84.84 85.30 86.09 90.92 93.19 93.55 93.94 96.04 102.10 102.36 102.77 103.13 86.28 86.86 88.50 93.77 94.69 95.19 95.63 99.12 103.69 104.06 104.54 105.31 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 57.64 68.74 79.30 87.66 54.47 63.71 77.93 92.75 51.15 63.38 74.00 84.44 60.00 71.60 82.91 90.92 56.65 66.38 81.62 96.04 53.17 66.13 77.54 88.83 61.52 73.54 86.03 93.77 59.32 69.49 85.83 99.12 55.67 69.29 81.59 93.30 PI 26.66 26.69 26.72 27.02 27.32 27.34 27.37 27.43 28.05 28.06 28.09 28.11 26.80 26.83 26.89 27.28 27.46 27.49 27.53 27.70 28.21 28.23 28.26 28.30 26.91 26.96 27.09 27.52 27.59 27.63 27.67 27.96 28.34 28.37 28.41 28.48 TC 80.23 80.57 81.04 85.22 88.24 88.49 88.77 90.05 96.81 96.98 97.27 97.52 81.82 82.30 83.40 88.34 89.92 90.30 90.66 93.38 98.58 98.85 99.23 99.65 83.20 83.77 85.90 91.08 91.33 91.82 92.34 96.35 100.04 100.45 100.90 101.99 30°C SHC 56.26 67.20 77.66 85.22 53.18 62.30 76.42 90.05 49.96 62.04 72.60 83.01 58.57 70.02 80.75 88.34 55.35 64.93 80.08 93.38 51.98 64.73 76.10 87.24 59.96 71.95 84.35 91.08 58.00 68.00 84.22 96.35 54.45 67.84 80.12 91.25 PI 28.65 28.68 28.72 29.07 29.33 29.35 29.39 29.49 30.09 30.11 30.14 30.16 28.79 28.83 28.92 29.34 29.48 29.51 29.55 29.79 30.25 30.28 30.31 30.35 28.90 28.95 29.13 29.58 29.60 29.65 29.70 30.05 30.38 30.42 30.47 30.57 TC 77.13 77.49 78.16 82.61 84.91 85.17 85.43 87.34 93.22 93.40 93.69 93.96 78.62 79.10 80.70 85.59 86.47 86.87 87.25 90.56 94.85 95.14 95.51 96.20 79.94 80.48 83.10 88.20 87.78 88.29 88.89 93.39 96.24 96.65 97.07 98.69 35°C SHC 54.80 65.56 75.66 82.61 51.83 60.82 74.83 87.34 48.72 60.61 71.13 81.54 56.98 68.34 78.23 85.59 53.99 63.42 78.48 90.56 50.73 63.26 74.60 85.39 58.32 70.26 82.44 88.20 56.59 66.44 82.41 93.39 53.21 66.32 78.58 88.87 PI 30.91 30.95 31.01 31.41 31.62 31.64 31.68 31.85 32.40 32.42 32.45 32.48 31.05 31.09 31.24 31.69 31.76 31.80 31.84 32.15 32.56 32.59 32.63 32.69 31.17 31.22 31.46 31.93 31.89 31.94 31.99 32.42 32.69 32.73 32.78 32.94 TC 69.41 69.78 70.75 75.04 76.49 76.77 77.03 79.43 84.08 84.25 84.53 84.86 70.76 71.19 73.19 77.71 77.86 78.25 78.66 82.31 85.51 85.79 86.13 87.20 71.90 72.37 75.33 80.04 79.03 79.49 80.32 84.85 86.73 87.11 87.49 89.72 40°C SHC 50.02 60.00 68.90 75.04 47.37 55.70 68.79 79.43 44.57 55.56 65.42 75.12 51.96 62.59 71.30 77.71 49.40 58.11 72.13 82.31 46.46 58.02 68.66 78.94 53.17 64.36 74.95 80.04 51.71 60.92 75.35 84.85 48.80 60.86 72.36 81.72 PI 33.45 33.49 33.59 34.03 34.17 34.20 34.24 34.49 34.98 35.00 35.03 35.07 33.58 33.63 33.83 34.31 34.32 34.36 34.40 34.80 35.13 35.16 35.21 35.32 33.70 33.75 34.06 34.55 34.44 34.49 34.58 35.07 35.26 35.31 35.36 35.60 TC 64.48 64.80 66.40 70.56 71.12 71.42 71.71 74.80 78.28 78.49 78.76 79.45 65.67 66.05 68.66 73.02 72.40 72.77 73.36 77.47 79.59 79.90 80.22 81.99 66.69 67.15 70.63 75.18 73.43 73.87 75.20 79.82 80.69 81.09 81.44 84.53 46°C SHC 47.32 57.02 64.71 70.56 44.96 52.99 65.77 74.80 42.34 52.93 62.60 71.59 49.11 59.51 67.09 73.02 46.91 55.34 68.60 77.47 44.21 55.31 65.76 75.27 50.26 61.26 70.62 75.18 49.00 58.04 71.15 79.82 46.44 58.06 69.35 77.60 PI 36.83 36.87 37.05 37.52 37.58 37.61 37.65 38.01 38.41 38.43 38.47 38.55 36.96 37.01 37.30 37.80 37.72 37.76 37.84 38.32 38.56 38.59 38.64 38.85 37.09 37.13 37.52 38.05 37.84 37.90 38.05 38.59 38.69 38.74 38.79 39.16 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 49.890 49.890 57.708 57.708 60.313 60.313 88.978 88.978 104.613 104.613 112.431 112.431 120.249 120.249 17 49.807 49.807 56.904 56.904 59.270 59.270 87.619 87.619 101.815 101.815 109.323 109.323 116.832 116.832 19 49.725 49.725 56.101 56.101 58.226 58.226 86.260 86.260 99.017 99.017 106.216 106.216 113.414 113.414 21 49.642 49.642 55.298 55.298 57.183 57.183 84.900 84.900 96.220 96.220 103.108 103.108 109.997 109.997 23 48.435 48.435 54.213 54.213 56.139 56.139 81.859 81.859 93.422 93.422 100.001 100.001 106.580 106.580 25 47.227 47.227 53.129 53.129 55.096 55.096 78.818 78.818 90.624 90.624 96.893 96.893 103.163 103.163 27 46.019 46.019 52.044 52.044 54.052 54.052 75.776 75.776 87.826 87.826 93.786 93.786 99.746 99.746 92 R22 MODELS (HEATPUMP) MODEL : MDB350BR3 / MMC100BR x 1 + MMC125BR x 2 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 9450 19°C 22°C 16°C 10500 19°C 22°C 16°C 11550 19°C 22°C EDB TC 95.81 96.18 96.53 100.36 105.26 105.53 105.94 106.55 115.49 115.65 115.98 116.31 97.83 98.33 99.02 104.15 107.41 107.81 108.30 110.00 117.72 118.00 118.45 118.87 99.56 100.20 101.60 107.50 109.20 109.75 110.33 113.57 119.59 119.99 120.56 121.16 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 68.48 81.57 93.89 100.36 64.69 75.57 92.22 106.55 60.78 75.13 87.55 99.69 71.23 84.92 98.44 104.15 67.24 78.71 96.54 110.00 63.13 78.40 91.69 104.83 73.17 87.20 101.60 107.50 70.37 82.37 101.50 113.57 66.03 82.12 96.45 110.45 PI 26.57 26.60 26.63 26.89 27.24 27.26 27.29 27.33 27.98 27.99 28.02 28.04 26.71 26.75 26.80 27.16 27.39 27.42 27.46 27.58 28.14 28.17 28.20 28.23 26.83 26.88 26.97 27.40 27.52 27.56 27.61 27.84 28.28 28.32 28.36 28.41 TC 92.77 93.15 93.59 97.83 101.99 102.25 102.60 103.51 111.84 112.01 112.35 112.68 94.69 95.20 96.08 101.47 104.01 104.41 104.84 107.19 113.95 114.24 114.70 115.09 96.30 96.94 98.77 104.65 105.68 106.24 106.73 110.62 115.72 116.13 116.67 117.53 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 66.97 79.87 92.14 97.83 63.29 74.03 90.55 103.51 59.44 73.64 85.98 98.11 69.72 83.19 96.08 101.47 65.83 77.12 94.84 107.19 61.79 76.83 90.09 103.21 71.48 85.45 98.77 104.65 68.93 80.74 99.73 110.62 64.68 80.51 94.80 108.41 PI 28.40 28.43 28.46 28.78 29.10 29.12 29.15 29.22 29.88 29.89 29.92 29.95 28.54 28.58 28.65 29.06 29.25 29.28 29.33 29.50 30.04 30.07 30.11 30.14 28.67 28.71 28.85 29.31 29.38 29.43 29.48 29.78 30.19 30.22 30.27 30.33 TC 89.55 89.92 90.45 95.11 98.49 98.76 99.08 100.50 108.04 108.24 108.56 108.84 91.31 91.86 93.07 98.59 100.36 100.78 101.18 104.22 110.02 110.32 110.75 111.21 92.85 93.49 95.87 101.65 101.93 102.48 103.06 107.53 111.65 112.10 112.61 113.83 30°C SHC 65.37 78.08 90.24 95.11 61.79 72.39 88.80 100.50 58.05 72.09 84.36 96.45 68.05 81.36 93.07 98.59 64.31 75.45 93.04 104.22 60.40 75.21 88.42 101.37 69.67 83.60 95.87 101.65 67.40 79.01 97.86 107.53 63.27 78.83 93.09 106.02 PI 30.52 30.55 30.59 30.97 31.24 31.27 31.30 31.42 32.05 32.07 32.10 32.13 30.66 30.70 30.80 31.26 31.40 31.44 31.48 31.73 32.22 32.25 32.29 32.33 30.79 30.84 31.03 31.51 31.53 31.58 31.63 32.01 32.36 32.40 32.45 32.56 TC 86.08 86.49 87.24 92.20 94.77 95.06 95.34 97.48 104.04 104.24 104.56 104.87 87.75 88.28 90.07 95.52 96.50 96.95 97.38 101.07 105.86 106.18 106.59 107.36 89.22 89.82 92.75 98.44 97.97 98.54 99.21 104.23 107.41 107.87 108.34 110.15 35°C SHC 63.67 76.18 87.24 92.20 60.22 70.66 86.95 97.48 56.61 70.42 82.65 94.74 66.20 79.41 90.07 95.52 62.73 73.68 91.19 101.07 58.94 73.51 86.68 99.22 67.76 81.63 92.75 98.44 65.75 77.20 95.75 104.23 61.83 77.06 91.30 103.26 PI 32.93 32.97 33.03 33.46 33.68 33.70 33.74 33.92 34.51 34.53 34.57 34.60 33.08 33.12 33.27 33.75 33.83 33.87 33.92 34.25 34.68 34.71 34.76 34.82 33.20 33.25 33.51 34.01 33.97 34.02 34.08 34.53 34.82 34.87 34.92 35.09 TC 77.46 77.88 78.97 83.75 85.37 85.68 85.97 88.64 93.84 94.03 94.34 94.71 78.97 79.45 81.68 86.73 86.90 87.33 87.79 91.86 95.43 95.75 96.13 97.32 80.24 80.77 84.07 89.33 88.21 88.72 89.64 94.69 96.79 97.23 97.64 100.13 40°C SHC 58.12 69.72 78.97 83.75 55.05 64.72 79.93 88.64 51.79 64.56 76.02 87.28 60.38 72.72 81.68 86.73 57.39 67.52 83.81 91.86 53.98 67.42 79.78 91.72 61.78 74.78 84.07 89.33 60.08 70.78 87.55 94.69 56.70 70.72 84.07 94.95 PI 35.63 35.67 35.78 36.25 36.40 36.43 36.47 36.74 37.26 37.28 37.31 37.35 35.77 35.82 36.04 36.54 36.56 36.60 36.64 37.06 37.42 37.45 37.50 37.62 35.90 35.95 36.27 36.80 36.68 36.74 36.83 37.35 37.56 37.61 37.66 37.92 TC 71.96 72.33 74.11 78.75 79.37 79.71 80.03 83.48 87.37 87.60 87.90 88.67 73.29 73.72 76.63 81.50 80.80 81.21 81.87 86.46 88.83 89.17 89.53 91.50 74.43 74.94 78.83 83.90 81.95 82.44 83.92 89.08 90.05 90.50 90.90 94.34 46°C SHC 54.98 66.25 74.11 78.75 52.24 61.57 76.43 83.48 49.20 61.50 72.73 83.18 57.06 69.15 76.63 81.50 54.51 64.30 79.71 86.46 51.37 64.27 76.40 87.45 58.39 71.18 78.83 83.90 56.93 67.44 82.67 89.08 53.95 67.46 80.58 90.16 PI 39.23 39.27 39.46 39.96 40.03 40.06 40.10 40.48 40.91 40.93 40.97 41.06 39.37 39.42 39.73 40.26 40.18 40.22 40.30 40.81 41.07 41.11 41.16 41.39 39.50 39.55 39.97 40.53 40.31 40.36 40.53 41.11 41.21 41.26 41.32 41.71 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 60.849 60.849 70.402 70.402 73.586 73.586 108.614 108.614 127.720 127.720 137.273 137.273 146.825 146.825 17 60.744 60.744 69.420 69.420 72.312 72.312 105.289 105.289 124.303 124.303 133.478 133.478 142.653 142.653 19 60.639 60.639 68.439 68.439 71.039 71.039 101.965 101.965 120.887 120.887 129.684 129.684 138.481 138.481 21 60.533 60.533 67.457 67.457 69.765 69.765 98.640 98.640 117.471 117.471 125.889 125.889 134.308 134.308 23 59.065 59.065 66.135 66.135 68.492 68.492 96.680 96.680 114.055 114.055 122.095 122.095 130.136 130.136 25 57.596 57.596 64.812 64.812 67.218 67.218 94.719 94.719 110.638 110.638 118.301 118.301 125.963 125.963 27 56.127 56.127 63.490 63.490 65.944 65.944 92.758 92.758 107.222 107.222 114.506 114.506 121.791 121.791 93 R22 MODELS (HEATPUMP) MODEL : MDB400BR4 / MMC100BR x 4 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 10800 19°C 22°C 16°C 12000 19°C 22°C 16°C 13200 19°C 22°C EDB TC 114.46 114.90 115.33 119.90 125.76 126.08 126.56 127.30 137.98 138.17 138.55 138.95 116.87 117.48 118.29 124.42 128.32 128.80 129.39 131.41 140.63 140.97 141.51 142.01 118.94 119.71 121.38 128.43 130.46 131.12 131.81 135.67 142.87 143.34 144.03 144.75 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 78.58 93.60 107.74 119.90 74.24 86.72 105.83 127.30 69.74 86.21 100.46 114.39 81.74 97.44 112.97 124.42 77.16 90.32 110.78 131.41 72.44 89.97 105.21 120.29 83.97 100.07 116.63 128.43 80.75 94.52 116.47 135.67 75.77 94.24 110.67 126.75 PI 32.87 32.90 32.94 33.27 33.70 33.72 33.76 33.81 34.61 34.63 34.66 34.69 33.05 33.09 33.15 33.60 33.89 33.92 33.97 34.11 34.82 34.84 34.89 34.93 33.20 33.25 33.37 33.89 34.05 34.10 34.15 34.44 34.99 35.03 35.08 35.14 TC 110.83 111.28 111.81 116.88 121.85 122.15 122.57 123.67 133.61 133.82 134.23 134.62 113.12 113.73 114.78 121.22 124.26 124.73 125.26 128.06 136.13 136.48 137.03 137.50 115.05 115.81 118.00 125.03 126.25 126.92 127.50 132.16 138.25 138.74 139.38 140.41 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 76.85 91.65 105.73 116.88 72.62 84.95 103.91 123.67 68.21 84.50 98.67 112.59 80.00 95.46 110.54 121.22 75.54 88.50 108.83 128.06 70.90 88.17 103.38 118.43 82.02 98.05 114.71 125.03 79.10 92.65 114.45 132.16 74.22 92.38 108.79 124.40 PI 35.13 35.17 35.21 35.60 35.99 36.02 36.06 36.14 36.96 36.97 37.01 37.04 35.31 35.36 35.44 35.95 36.19 36.23 36.28 36.50 37.17 37.20 37.24 37.29 35.46 35.52 35.69 36.26 36.35 36.40 36.46 36.84 37.34 37.39 37.44 37.52 TC 106.98 107.43 108.05 113.63 117.66 117.98 118.36 120.06 129.08 129.31 129.70 130.03 109.09 109.74 111.19 117.78 119.89 120.40 120.88 124.51 131.43 131.80 132.31 132.86 110.93 111.69 114.53 121.43 121.77 122.43 123.12 128.46 133.39 133.93 134.53 135.99 30°C SHC 75.01 89.59 103.55 113.63 70.91 83.07 101.90 120.06 66.62 82.72 96.80 110.68 78.09 93.36 107.67 117.78 73.80 86.58 106.77 124.51 69.31 86.31 101.47 116.32 79.95 95.93 112.47 121.43 77.34 90.66 112.30 128.46 72.60 90.45 106.82 121.66 PI 37.75 37.79 37.84 38.31 38.65 38.68 38.72 38.86 39.65 39.67 39.71 39.75 37.93 37.98 38.11 38.66 38.85 38.89 38.94 39.25 39.86 39.89 39.94 40.00 38.09 38.15 38.39 38.98 39.01 39.07 39.13 39.60 40.04 40.08 40.14 40.28 TC 102.84 103.33 104.22 110.15 113.22 113.56 113.90 116.46 124.30 124.54 124.92 125.28 104.83 105.47 107.60 114.12 115.29 115.83 116.34 120.74 126.46 126.85 127.34 128.26 106.59 107.30 110.81 117.60 117.04 117.72 118.52 124.52 128.32 128.86 129.43 131.59 35°C SHC 73.06 87.41 100.88 110.15 69.10 81.09 99.77 116.46 64.96 80.81 94.84 108.72 75.97 91.12 104.31 114.12 71.98 84.55 104.64 120.74 67.63 84.35 99.46 113.85 77.76 93.67 109.91 117.60 75.45 88.58 109.88 124.52 70.95 88.43 104.77 118.49 PI 40.74 40.78 40.86 41.39 41.66 41.70 41.74 41.97 42.70 42.72 42.76 42.80 40.92 40.97 41.16 41.75 41.85 41.90 41.96 42.36 42.91 42.94 43.00 43.08 41.07 41.14 41.45 42.07 42.02 42.08 42.16 42.72 43.08 43.13 43.20 43.40 TC 92.55 93.04 94.34 100.06 101.99 102.36 102.71 105.90 112.11 112.34 112.70 113.14 94.34 94.92 97.58 103.61 103.82 104.33 104.87 109.75 114.01 114.39 114.85 116.26 95.86 96.49 100.44 106.72 105.38 105.99 107.10 113.13 115.64 116.15 116.65 119.63 40°C SHC 66.70 80.01 91.86 100.06 63.17 74.26 91.73 105.90 59.43 74.08 87.23 100.15 69.28 83.45 95.07 103.61 65.86 77.48 96.17 109.75 61.95 77.36 91.55 105.25 70.89 85.81 99.93 106.72 68.95 81.22 100.46 113.13 65.07 81.15 96.48 108.95 PI 44.08 44.12 44.26 44.84 45.03 45.07 45.11 45.44 46.09 46.11 46.16 46.20 44.25 44.31 44.58 45.20 45.22 45.27 45.33 45.85 46.29 46.33 46.39 46.54 44.40 44.48 44.87 45.53 45.38 45.45 45.57 46.21 46.47 46.52 46.59 46.91 TC 85.97 86.40 88.54 94.08 94.83 95.23 95.61 99.73 104.37 104.65 105.01 105.93 87.56 88.07 91.54 97.36 96.53 97.03 97.81 103.30 106.12 106.53 106.96 109.32 88.92 89.53 94.17 100.23 97.91 98.49 100.26 106.42 107.58 108.12 108.59 112.70 46°C SHC 63.10 76.02 86.28 94.08 59.94 70.65 87.70 99.73 56.45 70.57 83.46 95.45 65.48 79.35 89.45 97.36 62.55 73.78 91.47 103.30 58.95 73.75 87.67 100.35 67.01 81.69 94.16 100.23 65.33 77.39 94.86 106.42 61.91 77.41 92.47 103.46 PI 48.53 48.58 48.82 49.44 49.52 49.56 49.61 50.08 50.61 50.64 50.69 50.79 48.70 48.77 49.15 49.81 49.70 49.76 49.86 50.49 50.81 50.85 50.91 51.20 48.87 48.93 49.44 50.13 49.86 49.93 50.14 50.85 50.98 51.04 51.11 51.60 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 66.520 66.520 76.943 76.943 80.418 80.418 118.638 118.638 139.485 139.485 149.908 149.908 160.332 160.332 17 66.410 66.410 75.872 75.872 79.027 79.027 116.825 116.825 135.754 135.754 145.765 145.765 155.775 155.775 19 66.300 66.300 74.801 74.801 77.635 77.635 115.013 115.013 132.023 132.023 141.621 141.621 151.219 151.219 21 66.190 66.190 73.730 73.730 76.244 76.244 113.200 113.200 128.293 128.293 137.478 137.478 146.663 146.663 23 64.580 64.580 72.284 72.284 74.853 74.853 109.145 109.145 124.562 124.562 133.334 133.334 142.107 142.107 25 62.969 62.969 70.838 70.838 73.461 73.461 105.090 105.090 120.831 120.831 129.191 129.191 137.550 137.550 27 61.359 61.359 69.392 69.392 72.070 72.070 101.035 101.035 117.101 117.101 125.047 125.047 132.994 132.994 94 R22 MODELS (HEATPUMP) MODEL : MDB500BR4 / MMC125BR x 4 COOLING MODE AFR (CFM) Outdoor temperature EWB 16°C 13500 19°C 22°C 16°C 15000 19°C 22°C 16°C 16500 19°C 22°C EDB TC 134.38 134.91 135.41 140.78 147.65 148.03 148.60 149.46 162.00 162.22 162.68 163.14 137.22 137.93 138.89 146.09 150.66 151.23 151.91 154.29 165.12 165.51 166.15 166.73 139.64 140.55 142.51 150.78 153.17 153.95 154.75 159.29 167.74 168.30 169.10 169.95 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 19°C SHC 99.84 118.93 135.41 140.78 94.32 110.19 134.47 149.46 88.62 109.54 127.65 145.35 103.86 123.81 138.89 146.09 98.04 114.76 140.76 154.29 92.04 114.31 133.68 152.84 106.69 127.14 142.51 150.78 102.60 120.10 147.99 159.29 96.28 119.74 140.62 161.05 PI 37.83 37.87 37.91 38.29 38.78 38.81 38.85 38.91 39.84 39.86 39.89 39.93 38.03 38.09 38.15 38.67 39.00 39.04 39.10 39.26 40.07 40.10 40.15 40.20 38.20 38.27 38.40 39.01 39.19 39.24 39.31 39.64 40.27 40.32 40.38 40.44 TC 130.13 130.65 131.27 137.23 143.06 143.42 143.91 145.20 156.87 157.12 157.59 158.06 132.82 133.53 134.77 142.33 145.89 146.45 147.06 150.35 159.83 160.24 160.89 161.44 135.07 135.97 138.55 146.80 148.23 149.02 149.70 155.17 162.31 162.89 163.65 164.85 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Total Cooling Capacity (kW) SHC: Sensible Heat Capacity (kW) PI: Power Input 25°C SHC 97.64 116.45 131.27 137.23 92.27 107.94 132.03 145.20 86.66 107.37 125.37 143.05 101.65 121.29 134.77 142.33 95.98 112.45 138.27 150.35 90.08 112.03 131.36 150.48 104.22 124.58 138.55 146.80 100.50 117.72 145.41 155.17 94.31 117.38 138.22 158.07 PI 40.43 40.47 40.52 40.97 41.43 41.46 41.50 41.60 42.54 42.56 42.60 42.63 40.64 40.69 40.79 41.37 41.65 41.69 41.75 42.01 42.78 42.81 42.86 42.91 40.81 40.88 41.08 41.73 41.84 41.90 41.97 42.40 42.98 43.03 43.09 43.18 TC 125.60 126.13 126.87 133.41 138.14 138.53 138.97 140.96 151.55 151.83 152.27 152.67 128.08 128.84 130.55 138.29 140.77 141.36 141.93 146.19 154.32 154.74 155.34 155.99 130.24 131.14 134.47 142.58 142.97 143.74 144.56 150.83 156.61 157.25 157.95 159.67 30°C SHC 95.31 113.84 126.87 133.41 90.09 105.55 129.47 140.96 84.65 105.11 122.99 140.63 99.22 118.62 130.55 138.29 93.77 110.00 135.66 146.19 88.06 109.66 128.92 147.79 101.59 121.89 134.47 142.58 98.27 115.19 142.68 150.83 92.25 114.93 135.73 154.59 PI 43.45 43.49 43.55 44.09 44.48 44.52 44.57 44.73 45.64 45.66 45.70 45.75 43.65 43.72 43.86 44.50 44.71 44.76 44.82 45.17 45.88 45.91 45.97 46.03 43.83 43.91 44.18 44.86 44.89 44.96 45.04 45.58 46.08 46.13 46.20 46.35 TC 120.75 121.31 122.36 129.32 132.93 133.34 133.73 136.73 145.94 146.22 146.66 147.09 123.08 123.83 126.34 133.98 135.36 135.99 136.59 141.77 148.48 148.93 149.51 150.59 125.14 125.99 130.10 138.07 137.42 138.21 139.16 146.20 150.65 151.30 151.96 154.50 35°C SHC 92.83 111.07 122.36 129.32 87.80 103.03 126.77 136.73 82.54 102.68 120.51 138.14 96.52 115.78 126.34 133.98 91.46 107.43 132.95 141.77 85.93 107.17 126.38 144.66 98.80 119.02 130.10 138.07 95.87 112.55 139.16 146.20 90.15 112.36 133.12 150.56 PI 46.88 46.94 47.03 47.64 47.95 47.99 48.04 48.30 49.14 49.16 49.21 49.26 47.09 47.16 47.37 48.05 48.17 48.23 48.29 48.76 49.38 49.42 49.48 49.58 47.27 47.35 47.70 48.42 48.36 48.43 48.52 49.17 49.58 49.64 49.72 49.95 TC 108.66 109.24 110.76 117.48 119.75 120.18 120.59 124.34 131.62 131.90 132.32 132.84 110.77 111.44 114.57 121.65 121.89 122.50 123.13 128.85 133.86 134.30 134.84 136.50 112.55 113.29 117.93 125.30 123.72 124.44 125.74 132.82 135.77 136.37 136.96 140.45 40°C SHC 84.75 101.66 110.76 117.48 80.26 94.36 116.55 124.34 75.51 94.13 110.84 127.26 88.03 106.03 114.57 121.65 83.68 98.45 122.20 128.85 78.71 98.30 116.32 133.73 90.08 109.04 117.93 125.30 87.60 103.20 125.74 132.82 82.67 103.11 122.58 138.44 PI 50.73 50.78 50.94 51.60 51.82 51.87 51.92 52.30 53.05 53.07 53.13 53.18 50.93 51.00 51.31 52.03 52.05 52.11 52.17 52.77 53.28 53.33 53.39 53.57 51.11 51.19 51.65 52.40 52.22 52.31 52.44 53.18 53.48 53.54 53.62 53.99 TC 100.93 101.45 103.95 110.46 111.33 111.81 112.26 117.10 122.54 122.87 123.30 124.38 102.80 103.40 107.48 114.31 113.34 113.92 114.83 121.28 124.60 125.08 125.58 128.35 104.40 105.12 110.57 117.69 114.95 115.64 117.71 124.95 126.31 126.94 127.50 132.32 46°C SHC 80.17 96.60 103.95 110.46 76.16 89.77 111.43 117.10 71.73 89.67 106.04 121.28 83.20 100.82 107.48 114.31 79.48 93.74 114.83 121.28 74.90 93.70 111.40 127.51 85.14 103.79 110.57 117.69 83.01 98.33 117.71 124.95 78.67 98.36 117.49 131.46 PI 55.85 55.91 56.19 56.90 56.99 57.04 57.09 57.64 58.25 58.28 58.34 58.46 56.05 56.13 56.57 57.32 57.20 57.27 57.38 58.11 58.48 58.53 58.60 58.92 56.24 56.31 56.91 57.70 57.39 57.47 57.71 58.53 58.67 58.74 58.82 59.38 Notes: 1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat. 2. shows nominal capacities. 3. Direct interpolation is permissible. Do not extrapolate. HEATING MODE Outdoor WB°C ID DB°C -9 -6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 88.437 88.437 102.332 102.332 106.963 106.963 157.908 157.908 185.697 185.697 199.591 199.591 213.485 213.485 17 88.282 88.282 100.904 100.904 105.112 105.112 152.166 152.166 180.730 180.730 194.074 194.074 207.418 207.418 19 88.127 88.127 99.477 99.477 103.260 103.260 146.423 146.423 175.762 175.762 188.557 188.557 201.352 201.352 21 87.972 87.972 98.049 98.049 101.408 101.408 140.680 140.680 170.795 170.795 183.040 183.040 195.285 195.285 23 85.839 85.839 96.128 96.128 99.557 99.557 138.786 138.786 165.828 165.828 177.523 177.523 189.218 189.218 25 83.707 83.707 94.206 94.206 97.705 97.705 136.893 136.893 160.861 160.861 172.006 172.006 183.151 183.151 27 81.575 81.575 92.284 92.284 95.854 95.854 134.999 134.999 155.894 155.894 166.489 166.489 177.084 177.084 95 Dimensional Da ta Data INDOOR MODEL: MDB 075/100 BR (HORIZONTAL AIR DISCHARGE ONLY) Dimension in mm MODEL: MDB 125CR (HORIZONTAL AIR DISCHARGE ONLY) Dimension in mm 96 MODEL: MDB 150BR2 (STANDARD: HORIZONTAL AIR DISCHARGE; OPTIONAL: VERTICAL AIR DISCHARGE) Dimension in mm MODEL: MDB 200BR2 (STANDARD: HORIZONTAL AIR DISCHARGE; OPTIONAL: VERTICAL AIR DISCHARGE) Dimension in mm 97 MODEL: MDB 250BR2 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm MODEL: MDB 300BR3 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm 98 MODEL: MDB 350BR3 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm MODEL: MDB 400/500 BR4 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm 99 MODEL: MDSB 200BR2 (STANDARD: HORIZONTAL AIR DISCHARGE; OPTIONAL: VERTICAL AIR DISCHARGE) Dimension in mm MODEL: MDSB 250BR2 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm 100 MODEL: MDSB 300BR3 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm MODEL: MDSB 350BR3 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm 101 MODEL: MDSB 400/500BR4 (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm 102 OUTDOOR MODEL: MMC100/125 BR (STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE) Dimension in mm MODEL: MMC 075CR Dimension in mm 103 Electrical Da ta Data MODEL INDOOR UNIT MDB075BR OUTDOOR UNIT MMC075CR INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 220~240 / 1 / 50 RATED INPUT POWER W 830 RATED RUNNING CURRENT A 3.7 MOTOR OUTPUT W 375 POWER SOURCE 6 POLES INSULATION GRADE V/Ph/Hz 220~240 / 1 / 50 RATED INPUT POWER W 740 RATED RUNNING CURRENT A 3.8 MOTOR OUTPUT W 480 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 6930 RATED INPUT POWER (HEATING) W 7530 RATED RUNNING CURRENT (COOLING) A 11.7 RATED RUNNING CURRENT (HEATING) A 12.0 LOCKED ROTOR AMP. A 95.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDB100BR OUTDOOR UNIT MMC100BR CLASS F INSULATION GRADE V/Ph/Hz 220~240 / 1 / 50 RATED INPUT POWER W 1800 RATED RUNNING CURRENT A 8.0 MOTOR OUTPUT POLES W 500 POWER SOURCE INDOOR MOTOR 4 CLASS F INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT INSULATION GRADE W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 104 Electrical Data - Heatpump MODEL INDOOR UNIT MDB125CR OUTDOOR UNIT MMC125BR INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 1100 RATED RUNNING CURRENT A 2.7 MOTOR OUTPUT W 1500 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 640 RATED RUNNING CURRENT A 1.4 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 9408 RATED INPUT POWER (HEATING) W 7736 RATED RUNNING CURRENT (COOLING) A 17.0 RATED RUNNING CURRENT (HEATING) A 15.1 LOCKED ROTOR AMP. A 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDB150BR2 OUTDOOR UNIT MMC075CR x 2 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 1630 RATED RUNNING CURRENT A 3.1 MOTOR OUTPUT POLES W 1500 POWER SOURCE 4 INSULATION GRADE V/Ph/Hz 220~240 / 1 / 50 RATED INPUT POWER W 740 RATED RUNNING CURRENT A 3.8 MOTOR OUTPUT INSULATION GRADE W 480 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR CLASS F CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 6930 RATED INPUT POWER (HEATING) W 7530 RATED RUNNING CURRENT (COOLING) A 11.7 RATED RUNNING CURRENT (HEATING) A 12.0 LOCKED ROTOR AMP. A 95.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 105 Electrical Data - Heatpump MODEL INDOOR UNIT MDB200BR2 OUTDOOR UNIT MMC100BR x 2 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 2730 RATED RUNNING CURRENT A 5.0 MOTOR OUTPUT W 3000 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDB250BR2 OUTDOOR UNIT MMC125BR x 2 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 3370 RATED RUNNING CURRENT A 6.3 MOTOR OUTPUT POLES W 4000 POWER SOURCE 4 INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 640 RATED RUNNING CURRENT A 1.4 MOTOR OUTPUT INSULATION GRADE W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR CLASS F CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 9408 RATED INPUT POWER (HEATING) W 7736 RATED RUNNING CURRENT (COOLING) A 17.0 RATED RUNNING CURRENT (HEATING) A 15.1 LOCKED ROTOR AMP. A 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 106 Electrical Data - Heatpump MODEL INDOOR UNIT MDB300BR3 OUTDOOR UNIT MMC100BR x 3 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 4000 RATED RUNNING CURRENT A 7.1 MOTOR OUTPUT W 4000 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDB350BR3 OUTDOOR UNIT MMC100BR x 1 INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 4510 RATED RUNNING CURRENT A 8.4 MOTOR OUTPUT POLES W 5500 POWER SOURCE INDOOR MOTOR 4 INSULATION GRADE CLASS F CLASS F V/Ph/Hz 380~415 / 3 / 50 380~415 / 3 / 50 RATED INPUT POWER W 660 640 RATED RUNNING CURRENT A 1.5 1.4 MOTOR OUTPUT INSULATION GRADE W 470 470 CLASS F CLASS F V/Ph/Hz 380~415 / 3 / 50 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR MMC125BR x 2 CLASS F CAPACITOR μF NIL NIL RATED INPUT POWER (COOLING) W 8607 9408 RATED INPUT POWER (HEATING) W 7865 7736 RATED RUNNING CURRENT (COOLING) A 16.0 17.0 RATED RUNNING CURRENT (HEATING) A 15.2 15.1 LOCKED ROTOR AMP. A 125.0 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 107 Electrical Data - Heatpump MODEL INDOOR UNIT MDB400BR4 OUTDOOR UNIT MMC100BR x 4 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 4835 RATED RUNNING CURRENT A 8.7 MOTOR OUTPUT W 5500 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDB500BR4 OUTDOOR UNIT MMC125BR x 4 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 8035 RATED RUNNING CURRENT A 14.7 MOTOR OUTPUT POLES W 11000 POWER SOURCE 4 INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 640 RATED RUNNING CURRENT A 1.4 MOTOR OUTPUT INSULATION GRADE W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR CLASS F CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 9408 RATED INPUT POWER (HEATING) W 7736 RATED RUNNING CURRENT (COOLING) A 17.0 RATED RUNNING CURRENT (HEATING) A 15.1 LOCKED ROTOR AMP. A 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 108 Electrical Data - Heatpump MODEL INDOOR UNIT MDSB200BR2 OUTDOOR UNIT MMC100BR x 2 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 2730 RATED RUNNING CURRENT A 5.0 MOTOR OUTPUT W 3000 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDSB250BR2 OUTDOOR UNIT MMC125BR x 2 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 3370 RATED RUNNING CURRENT A 6.3 MOTOR OUTPUT POLES W 4000 POWER SOURCE 4 INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 640 RATED RUNNING CURRENT A 1.4 MOTOR OUTPUT INSULATION GRADE W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR CLASS F CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 9408 RATED INPUT POWER (HEATING) W 7736 RATED RUNNING CURRENT (COOLING) A 17.0 RATED RUNNING CURRENT (HEATING) A 15.1 LOCKED ROTOR AMP. A 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 109 Electrical Data - Heatpump MODEL INDOOR UNIT MDSB300BR3 OUTDOOR UNIT MMC100BR x 3 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 4000 RATED RUNNING CURRENT A 7.1 MOTOR OUTPUT W 4000 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDSB350BR3 OUTDOOR UNIT MMC100BR x 1 INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 4510 RATED RUNNING CURRENT A 8.4 MOTOR OUTPUT POLES W 5500 POWER SOURCE INDOOR MOTOR 4 INSULATION GRADE CLASS F CLASS F V/Ph/Hz 380~415 / 3 / 50 380~415 / 3 / 50 RATED INPUT POWER W 660 640 RATED RUNNING CURRENT A 1.5 1.4 MOTOR OUTPUT INSULATION GRADE W 470 470 CLASS F CLASS F V/Ph/Hz 380~415 / 3 / 50 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR MMC125BR x 2 CLASS F CAPACITOR μF NIL NIL RATED INPUT POWER (COOLING) W 8607 9408 RATED INPUT POWER (HEATING) W 7865 7736 RATED RUNNING CURRENT (COOLING) A 16.0 17.0 RATED RUNNING CURRENT (HEATING) A 15.2 15.1 LOCKED ROTOR AMP. A 125.0 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 110 Electrical Data - Heatpump MODEL INDOOR UNIT MDSB400BR4 OUTDOOR UNIT MMC100BR x 4 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 4835 RATED RUNNING CURRENT A 8.7 MOTOR OUTPUT W 5500 POWER SOURCE 4 POLES INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 660 RATED RUNNING CURRENT A 1.5 MOTOR OUTPUT W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR CLASS F CLASS F INSULATION GRADE POWER SOURCE COMPRESSOR CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 8607 RATED INPUT POWER (HEATING) W 7865 RATED RUNNING CURRENT (COOLING) A 16.0 RATED RUNNING CURRENT (HEATING) A 15.2 LOCKED ROTOR AMP. A 125.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 MODEL INDOOR UNIT MDSB500BR4 OUTDOOR UNIT MMC125BR x 4 INSULATION GRADE INDOOR MOTOR CLASS F V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 8035 RATED RUNNING CURRENT A 14.7 MOTOR OUTPUT POLES W 11000 POWER SOURCE 4 INSULATION GRADE V/Ph/Hz 380~415 / 3 / 50 RATED INPUT POWER W 640 RATED RUNNING CURRENT A 1.4 MOTOR OUTPUT INSULATION GRADE W 470 V/Ph/Hz 380~415 / 3 / 50 POWER SOURCE OUTDOOR MOTOR POWER SOURCE COMPRESSOR CLASS F CLASS F CAPACITOR μF NIL RATED INPUT POWER (COOLING) W 9408 RATED INPUT POWER (HEATING) W 7736 RATED RUNNING CURRENT (COOLING) A 17.0 RATED RUNNING CURRENT (HEATING) A 15.1 LOCKED ROTOR AMP. A 110.0 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO13253 111 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH U1.4 CCT SLM AP 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. W iring Dia grams Diag MODEL : MDB075BR ~ MMC075CR 112 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH U1.4 CCT SLM AP 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB100BR ~ MMC100BR 113 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH U1-SB125 CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB125CR ~ MMC125BR 114 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH SEQUENTIAL CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB150BR2 ~ MMC075CR x 2 MDB200BR2 ~ MMC100BR x 2 115 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH SEQUENTIAL CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB250BR2 ~ MMC125BR x 2 116 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH SEQUENTIAL CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB300BR3 ~ MMC100BR x 3 117 1) WITH MAGNETIC CONTACTOR 2) WITH SEQUENTIAL CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. MODEL : MDB350BR3 ~ MMC100BR + MMC125BR x 2 118 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH SEQUENTIAL CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB400BR4 ~ MMC100BR x 4 119 NOTE: A MANUAL RESET CIRCUIT MUST BE PROVIDED AT THE FIELD SUPPLIED EXTERNAL STARTER BOARD FOR ALL PROTECTIVE DEVICES. 1) WITH MAGNETIC CONTACTOR 2) WITH SEQUENTIAL CONTROLLER 3) FOR 415V/50Hz 4) FOR EXPORT SPEC. MODEL : MDB500BR4 ~ MMC125BR x 4 120 Ser vicing And Maintenance Servicing The design concept of the Condensing Unit is such that all servicing can be done from the front and side of the unit. Upon removal of front and side panel, all the electrical “terminal box”, fan and motor assembly and compressor are easily accessible. Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surfaces once quarterly. However, if a unit is installed in area subjected to much oil, mist and dust, the coil must be regularly cleaned by qualified Air Conditioner Service Technicians to ensure sufficient heat exchange and proper operation. Otherwise, the systems life span might be shortened. Note: Avoid direct contact of any coil treatment material on the plastic part. This may cause plastic part to deform as a result of chemical reaction. CAUTION When the compressor is to be stopped for a long time, the crankcase heater should be energized for at least 6 hours before start of operation. Do not charge OXYGEN, ACETYLENE or other flammable and poisonous gases into the refrigeration cycle when performing a leakage test or an airtight test. These types of gases are extremely dangerous, because explosion can occur. It is recommended that nitrogen or refrigerant be charged for these types of tests. CAUTION FOR USE Bear the following points in mind to safeguard against malfunction and breakdown. Do not stick rods or other objects through the air outlet during operation since this may result to damage or injury The air conditioner must not re-start within 3 minutes after shutdown. (These models are equipped with a crankcase heater with the compressor). 121 Make sure the air conditioner is properly grounded by checking the ground terminal. MAINTENANCE For superb performance and lasting durability, please do not forget to conduct proper and regular maintenance. Cleaning The Outdoor Unit Heat Exchanger If you use your air conditioner for prolonged period of time, the outdoor unit heat exchanger will become dirty impairing its function and reducing the performance of the air conditioned. Consult your local dealer about the cleaning of the heat exchanger. 122 Troub leshooting oubleshooting When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself. No Fault conditions Possible causes / corrective actions 1 The air conditioner unit will not resume after power failure. • The auto restart function is not functioning. Please turn on the unit with the wireless / wired controller. 2 The compressor does not operate 3 minutes after the air conditioner unit is started. • • Protection against frequent starting. Wait for 3 or 4 minutes for the compressor to start operating by it self. 3 The airflow is too slow or room cannot be cooled sufficiently. • • • The air filter is dirty. The doors and windows are opened. The air suction and discharge of both indoor and outdoor units are clogged or blocked. The regulated temperature or temperature setting is not low enough. • 4 • Discharge airflow has bad odor. • 5 Condensation on the front air grille of the indoor unit. • • Cigarettes, smoke particles, perfume and others, which might have adhered onto the coil, may cause odor. Contact your nearest dealer. This is caused by air humidity after an extended period of operation. The set temperature is too low. Increase the temperature setting and operate the unit at high fan speed. 6 Water flowing out from the air conditioner. • Switch off the unit and contact your nearest dealer. This might be due to tilted installation. 7 Hissing airflow sound from the air conditioner unit during operation. • Liquid refrigerant flowing into the evaporator coil. 8 The wireless controller display is dim. • • • The batteries are discharged. The batteries are not correctly inserted. The assembly is not good. 9 Compressor operates continuously. • • Dirty air filter. Clean the air filter. Temperature setting too low (cooling). Use higher temperature setting. Temperature setting too high (heating), Use lower temperature setting. • 10 No cool air comes out during cooling cycle, or no hot air comes out during heating cycle. • • 11 On heating cycle, warm air does not come out. • 123 Temperature setting too high (cooling). Use lower temperature setting. Temperature setting too low (heating). Use higher temperature setting. Unit is in defrost mode. Heating operation will resume after defrost cycle ends. Diagnostic Guidelines By means of pressure reading: ● ● High side Low side ● High side Low side High side Low side High side Low side High side Low side Probable cause Too high A little high Normal Circuit Too low Data A little low Pressure ● ● ● ● ● ● 1. 2. 3. 4. Overcharged with refrigerant. Non-condensable gases in refrigerant circuit (e.g. air) Obstructed air-intake / discharge. Hot air short circuiting in outdoor unit. 1. Poor compression / no compression (compressor defective) 2. Reversing valve leaking. 1. 2. 3. 4. 5. 6. Undercharged with refrigerant. Refrigerant leakage. Air filter clogged / dirty (indoor unit). Indoor fan locked / seized. Defective defrost control, outdoor coil freeze up (heating). Outdoor fan locked / seized (heating). 1. 2. 3. 4. 5. Outdoor fan blocked (cooling). Outdoor coil dirty (cooling). Indoor fan locked / seized (heating). Indoor air filter clogged / dirty (heating). Non-condensable gases in refrigerant circuit (e.g. air) 1. Air intake temperature of indoor unit too high. ● 124 By means of diagnostic flow chart: Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insufficient cooling / heating”. i) Diagnosis of Electric Circuit The a) b) c) d) e) most common causes of air conditioner failure to “start” are : Voltage not within ±10% of rated voltage. Power supply interrupted. Improper control settings. Air conditioner is disconnected from main power source. Fuse blown or circuit breaker off. 125 ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insufficient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current. Satisfactory operation with temperature difference of air intake & discharge of indoor unit 8°C to 13°C. * ( * value is for reference only ) 126 Satisfactory operation with temperature difference of air intake & discharge of indoor unit 14°C to 20°C. * ( * value is for reference only ) 127 Exploded Vie w And P ar ts List iew Par arts HEATPUMP MODEL (INDOOR) HORIZONTAL AIR DISCHARGE MODEL: MDB075BR NO DESCRIPTION 1 BLOWER 2 MOTOR 3 FAN MOTOR BRACKET 4 ASSY COIL 5 TER. BOX NO 6 DESCRIPTION CAPACITOR 7.5MFD/440VAC 6.0MFD/440VAC Parts Not In Diagram CONTROL MODULE SARAN NET FILTER 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 128 MODEL : MDB100BR NO DESCRIPTION 1 MOTOR 2 BLOWER 3 ASSY COIL 4 TER. BOX Parts Not In Diagram SARAN NET FILTER CONTROL MODULE 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 129 MODEL : MDB125CR NO DESCRIPTION 1 MOTOR 2 BLOWER Parts Not In Diagram TXV VALVE CONTROL MODULE 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 130 MODEL : MDB150BR2 NO DESCRIPTION 1 BLOWER 2 MOTOR Parts Not In Diagram TXV VALVE CONTROL MODULE 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 131 MODEL : MDB200BR2 NO DESCRIPTION NO 1 ASSY, BASE PAN 15 DESCRIPTION ASSY, PANEL SMALL SIDE L 2 BLOWER 16 ASSY, TER. BOX 3 SUPT, BLOWER L 17 ASSY, PANEL F 4 SUPT, BLOWER R 18 FLANGE, BLOWER T/B 5 PULLEY, 2 SPZ 140/1610 6 BASE, MOTOR UPPER FLANGE, BLOWER L/R 19 ASSY, PANEL T BASE, MOTOR LOWER 20 COVER, BLOWER SUPT, MOTOR BRACKET L 21 ASSY, FILTER SUPT. T/B 7 MOTOR 8 PULLEY, 2 SPZ 80/1210 SUPPORT, FILTER L/R 22 PANEL, SIDE BIG L 23 COVER, TER. BOX 9 BELT 10 ASSY, DRAIN PAN 11 ASSY, COIL FILTER, AAF R29 12 COVER, COIL SIDE R HANDSET, WIRED SEQ LCD 13 PANEL, SIDE R CONTROL MODULE 14 COVER, COIL SIDE L Parts Not In Diagram 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 132 MODEL : MDB250BR2 NO DESCRIPTION NO DESCRIPTION 1 ASSY, BASE PAN 14 COVER, COIL SIDE R 2 BLOWER 15 PANEL, SMALL SIDE R 3 SUPT, BLOWER 16 ASSY, FRONT PANEL 4 SUPT, BLOWER 17 COVER, BLOWER 5 PULLEY, 2 SPZ 180/2012 18 ASSY, TOP PANEL 6 BASE, MOTOR UPPER 19 FLANGE, BLOWER T/B BASE, MOTOR LOWER FLANGE, BLOWER L/R SUPT. MOTOR BRACKET L 20 ASSY, FILTER SUPT. T/B 7 MOTOR ASSY, FILTER R/CENTRE 8 PULLEY, 2 SPZ 90/1610 FLANGE, FILTER L/R 9 BELT 10 ASSY, DRAIN PAN 21 PANEL, SIDE BIG R 11 ASSY, COIL FILTER, AAF R29 12 COVER, COIL SIDE L HANDSET, WIRED SEQ LCD 13 PANEL, SIDE L CONTROL MODULE Parts Not In Diagram 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 133 MODEL : MDB300BR3 NO DESCRIPTION NO DESCRIPTION 1 ASSY, BASE PAN 14 COVER, COIL SIDE R 2 BLOWER 15 PANEL, SMALL SIDE R 3 SUPT, BLOWER 16 ASSY, FRONT PANEL 4 SUPT, BLOWER 17 COVER, BLOWER 5 PULLEY, 2 SPZ 180/2012 18 ASSY, TOP PANEL 6 BASE, MOTOR UPPER 19 FLANGE, BLOWER T/B BASE, MOTOR LOWER FLANGE, BLOWER L/R SUPT. MOTOR BRACKET L 20 ASSY, FILTER SUPT. T/B 7 MOTOR 8 PULLEY, 2 SPZ 90/1610 ASSY, FILTER R/CENTRE 9 BELT 10 ASSY, DRAIN PAN 11 ASSY, COIL FILTER, AAF R29 12 COVER, COIL SIDE L HANDSET, WIRED SEQ LCD 13 PANEL, SIDE L CONTROL MODULE FLANGE, FILTER L/R 21 PANEL, SIDE BIG R Parts Not In Diagram 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 134 MODEL : MDB350BR3 NO DESCRIPTION NO DESCRIPTION 1 ASSY, BASE PAN 14 COVER, COIL SIDE R 2 BLOWER 15 PANEL, SMALL SIDE R 3 SUPT, BLOWER L 16 ASSY, FRONT PANEL 4 SUPT, BLOWER R 17 COVER, BLOWER 5 PULLEY, 2 SPZ 250/2012 18 ASSY, TOP PANEL 6 BASE, MOTOR UPPER 19 FLANGE, BLOWER L/R BASE, MOTOR LOWER FLANGE, BLOWER T/B SUPT, MOTOR BRACKET L 20 ASSY, FILTER SUPT. T/B SUPT, MOTOR BRACKET R ASSY, FILTER R/CENTRE 7 MOTOR SUPT, FILTER L/R 8 PULLEY, 2 SPZ 125/1610 9 BELT 21 PANEL, SIDE BIG R Parts Not In Diagram 10 ASSY, DRAIN PAN FILTER, AAF R29 11 ASSY, COIL HANDSET, WIRED SEQ LCD 12 COVER, COIL SIDE L CONTROL MODULE 13 PANEL, SIDE L 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 135 MODEL : MDB400BR4 NO DESCRIPTION NO DESCRIPTION 1 ASSY, BASE PAN 15 COVER, COIL SIDE R 2 BLOWER 16 PANEL, SIDE BACK R 3 SUPT, BLOWER L 17 PANEL, SIDE FRONT L/R 4 SUPT, BLOWER R 18 ASSY, FRONT PANEL 5 SUPT, BLOWER F/B 19 COVER, BLOWER 6 PULLEY, 2 SPA 250/2517 20 ASSY, TOP PANEL 7 BASE, MOTOR UPPER 21 FLANGE, BLOWER L/R 22 SUPPORT, FILTER L/R BASE, MOTOR LOWER FLANGE, BLOWER T/B SUPT, MOTOR BRACKET L 8 MOTOR 9 PULLEY, 2 SPA 106/1610 10 BELT 11 ASSY, DRAIN PAN 12 ASSY, COIL COVER, FILTER SUPT, FILTER T/B 23 PANEL, SIDE FRONT L/R Parts Not In Diagram FILTER, AAF R29 13 COVER, COIL SIDE L HANDSET, WIRED SEQ LCD 14 PANEL, SIDE BACK L CONTROL MODULE 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 136 MODEL : MDB500BR4 NO DESCRIPTION NO DESCRIPTION 1 ASSY, BASE PAN 15 COVER, COIL SIDE R 2 BLOWER 16 PANEL, SIDE BACK R HEADER 3 SUPT, BLOWER L 17 PANEL, SIDE FRONT L/R 4 SUPT, BLOWER R 18 ASSY, PANEL F 5 SUPT, BLOWER F/B 19 COVER, BLOWER 6 PULLEY, 2 SPA 315/2517 20 ASSY, PANEL T 7 BASE, MOTOR UPPER 21 FLANGE, BLOWER L/R BASE, MOTOR LOWER FLANGE, BLOWER T/B SUPT, MOTOR BRACKET L 8 22 MOTOR 9 PULLEY, 2 SPA 150/2012 10 BELT 11 ASSY, DRAIN PAN 12 ASSY, COIL SUPT, FILTER L/R COVER, FILTER SUPT, FILTER T/B 23 PANEL, SIDE FRONT L/R Parts Not In Diagram FILTER, AAF R29 13 COVER, COIL SIDE L HANDSET, WIRED SEQ LCD 14 PANEL, SIDE BACK L CONTROL MODULE 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 137 HEATPUMP MODEL HORIZONTAL AIR DISCHARGE MODEL : MMC075CR NO DESCRIPTION NO DESCRIPTION 1 STRUC. BACK R 14 ORIFICE SUPT. PLATE 2 ASSY, TER. BOX 15 ASSY, BASE PAN 3 TOP PANEL 16 COMPRESSOR 4 ACCUMULATOR 17 SERVICE PANEL 5 STRUC. FRONT L 18 VALVE PLATE 6 ASSY, COIL 19 ACESS VALVE 7 PARTITION 20 ACESS VALVE 8 BRACKET, FAN MOTOR 9 PROPELLER FAN 4-WAY VALVE 10 ORIFICE PLATE TXV VALVE 11 FAN GUARD PHASE PROTECTOR 12 STRUC. FRONT R CAPACITOR 13 MOTOR PRESS. SWITCH, 426PSI Parts Not In Diagram 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 138 VERTICAL DISCHARGE MODEL : MMC100 / 125 BR 139 VERTICAL DISCHARGE MODEL : MMC100 / 125 BR NO 1 2 DESCRIPTION NO FAN GUARD 14 DESCRIPTION COMPRESSOR MMC100BR MMC100BR MMC125BR MMC125BR PROPELLER FAN 15 MMC100BR 16 ACCUMULATOR ASSY, STRUC. BACK L MMC125BR MMC100BR 3 PANEL, TOP F MMC125BR 4 STRUC, TOP R 17 5 MOTOR 18 6 7 HOISTING BRACKET ASSY, COIL L MMC100BR MMC100BR MMC125BR MMC125BR BRACKET, FAN MOTOR 19 ASSY, STRUC. FRONT L MMC100BR 21 PLATE, ORIFICE MMC125BR MMC100BR ASSY,TERMINAL BOARD MMC125BR 21 MMC100BR MMC125BR STRUC, TOP L Parts Not In Diagram 8 ASSY, BASE PAN PANEL, SERVICE T 9 ASSY, STRUC. FRONT R. ASSY, ACCESS VALVE 10 ASSY, COIL R PRESS. SWITCH, 426PSI MMC100BR PRESS. SWITCH, 7PSI MMC125BR PHASE PROTECTOR, PP1.03 11 ASSY, STRUC. BACK R VALVE, REV 4 WAY MMC100BR FILTER DRIER MMC125BR VALVE, TXV 12 T/B PANEL MMC100BR, TCLE 7.5HCA 13 SUPT, ORIFICE PLATE MMC125BR, TCLE 10HCA 1. ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 140 Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. © 2010 McQuay International 306