Download Manitowoc I0500 Specifications
Transcript
I0300 SERIES I0300A Self-Contained Air-Cooled Model Characteristics vary depending on operating conditions. CYCLE TIMES Freeze Time + Harvest Time = Total Cycle Time Freeze Time Air Temp. Entering Condenser °F/°C 50/10 70/21 90/32 70/21 9.6-11.5 10.8-12.9 12.3-14.6 80/27 10.6-12.6 12.3-14.6 13.5-16.0 90/32 11.8-14.0 13.9-16.4 15.0-17.7 100/38 13.2-15.7 14.6-17.3 16.2-19.2 110/43 15.0-17.7 15.8-18.7 17.7-20.9 Water Temperature °F/°C Harvest Time1 1-2.5 1 Times in minutes 24 HOUR ICE PRODUCTION Air Temp. Entering Condenser °F/°C Water Temperature °F/°C1 50/10 70/21 90/32 70/21 310 280 250 80/27 285 250 230 90/32 260 225 210 100/38 235 215 195 110/43 210 200 180 1 Based on average ice slab weight of 2.40 - 2.80 lb. OPERATING PRESSURES Air Temp Entering Condenser °F/°C Freeze Cycle Discharge Pressure PSIG Harvest Cycle Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG1 75-100 50/10 195-245 50-20 135-160 70/21 195-260 50-20 135-165 80-110 80/27 220-290 60-24 150-170 90-120 90/32 240-320 60-25 170-195 115-135 100/38 285-370 70-28 200-220 130-155 110/43 330-415 78-32 230-250 150-175 1 Suction pressure drops gradually throughout the freeze cycle 226 Part Number STH025 02/12