´ Communicator cannot engage the telephone line For telemonitoring calls check that: Ø the alarm generating event is coded; Øthe Central Station telephone number, activated by the call generating event, is programmed properly. For voice calls check that: Ø the telephone number is programmed properly; Ø the telephone number is programmed as "Voice-call" and a voice-call message is programmed for the event in question. ´ The communicator engages the telephone line but cannot complete the call Check that: Ø the dial tone is correct, if not, disable the Tone Check; Ø the telephone line (connected to the Control panel) supports the programmed dialling mode; Ø the telephone number is correct (N.B. When connected to a switchboard etc. ----the first number should be the number that will engage the PSTN line). For telemonitoring calls check that: Ø the programmed protocol is used by the Central Station; Ø the Customer Code is programmed properly; Ø the call generating event code is programmed properly. ´ The Personal Computer cannot connect to the Main Unit. Check that: Ø the system is disarmed, and is not in the programming phase; Ø the serial port is the correct one, and is functioning properly; Ø the connections correspond to those indicated on page 75 ----for selfmade serial cables. 84 Security System Control Panels Omnia8/4