Download Asko H8 Specifications

Transcript
rum Wa
5. PCB Manual Test Mode
- PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
: Press power button -> Press "SPIN" button 3 times with pressing "WASH" button -> "X X X" will be
shown on LED display-> Whenever pressing "Signal" button 1 time, below process will be occurred.
- "X X X' : Program version display
Step
Display
Details
1
L_C
Door Lock Close
2
run
001
Running times count
3
E5
0
E5 Error count
4
E6
0
E6 Error count
5
E7
0
E7 Error count
6
E8
0
E8 Error count
7
F
Do not use
8
H
Hot Valve on
9
C
Cold Valve on
10
P
Pre Wash Valve on
11
d
Do not use
12
b
Bleach Valve
13
dr
Drainage pump on
14
L_O
Door Lock Open
2) More details
- When turn on 'LOCK' signal, all process is conducting normaly.
- In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
38