Download Bay Networks 302403-B Technical data
Transcript
kombk.book Page 20 Thursday, February 18, 1999 10:59 AM Using the BayStack 350 10/100/1000 Series Switch • Filtering Database Identifier (FID) --- the specific filtering/forwarding database within the BayStack 350 switch that is assigned to each VLAN. The current version of software assigns all VLANs to the same FID. This is referred to as Shared VLAN Learning in the IEEE 802.1Q specification. The default configuration settings for BayStack 350 switches have all ports set as untagged members of VLAN 1 with all ports configured as PVID = 1. Every VLAN is assigned a unique VLAN identifier (VID) which distinguishes it from all other VLANs. In the default configuration example shown in Figure 1-9, all incoming packets are assigned to VLAN 1 by the default port VLAN identifier (PVID =1). Untagged packets enter and leave the switch unchanged. 802.1Q switch VLAN 1 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 PVID = 1 DA CRC SA Incoming untagged packet Data Outgoing untagged packet (unchanged) CRC Data SA DA Key By default: All ports are assigned PVID = 1 All ports are untagged members of VLAN 1 BS35010A Figure 1-9. Default VLAN Settings To configure VLANs, a user can reconfigure the switch ports as tagged or untagged members of specific VLANs (see Figure 1-10 through Figure 1-13). 1-20 304376-B Rev 00