MCM1062W FOR THE PLUMBER Water Supply The recommended water supply line is a 3/8-inch O.D. tubing with a minimum operating pressure of 20 PSIG and a maximum of 80 PSIG. A separate water inlet is required for the condenser water supply. Connect to cold water supply line with standard plumbing fittings, with shut off valve installed in an accessible place between the water supply and the cuber. ln some cases a plumber will be required. Drain Connections: Drain tubing and fittings are supplied with the ice bin. All drains are gravity type and must have a minimum of 1/4-inch fall per foot on horizontal runs. The drains to be installed must conform with the local plumbing code. The water cooled condenser requires a separate drain line, and is NOT to be vented. Install a vertical open vent on the drain line(s) high point to ensure good draining. The ideal drain receptacle is a trapped and vented floor drain. September 1993 Page 5