Download Mitsubishi MXZ-2A52VA Service manual

Transcript
Revision H:
• Indoor units combinations for 42 class
have been added.
• MXZ-3A54VA- E7 and MXZ-4A71VA- E7
have been added.
SPLIT-TYPE AIR CONDITIONERS
Please void OB377 REVISED EDITION-G.
OUTDOOR UNIT
SERVICE MANUAL
Models
MXZ-2A30VA
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A40VA
MXZ-2A52VA
MXZ-2A52VA
MXZ-3A54VA
MXZ-3A54VA
MXZ-3A54VA
MXZ-3A54VA
MXZ-3A54VA
MXZ-3A54VA
MXZ-3A54VA
MXZ-4A71VA
-
HFC
utilized
No. OB377
REVISED EDITION-H
R410A
MXZ-4A71VA - E2
MXZ-4A71VA - E3
MXZ-4A71VA - E4
MXZ-4A71VA - E5
MXZ-4A71VA - E6
MXZ-4A71VA - E7
MXZ-4A80VA - E1
MXZ-4A80VA - E2
MXZ-5A100VA - E1
E1
E2
E1
E2
E1
E2
E1
E2
E3
Indoor unit service manual
MSZ-FA•VA Series (OB371)
MSZ-GA•VA Series (OB378, OB388)
MSZ-CB•VA Series (OB441)
MSZ-GC•VA Series (OBH468)
MSZ-GE•VA Series (OBH515)
MSZ-FD•VA Series (OBH488)
E4
E5
E6
E7
E1
CONTENTS
MXZ-4A80VA-
E1
NOTE:
• RoHS compliant products have <G> mark on the spec
name plate.
For servicing of RoHS compliant products, refer to the
RoHS Parts List.
1. TECHNICAL CHANGES ··································· 2
2. PART NAMES AND FUNCTIONS ····················· 8
3. INDOOR/OUTDOOR
CORRESPONDENCE TABLE ························ 10
4. INDOOR UNITS COMBINATION ···················· 14
5. SPECIFICATION ·············································· 61
6. NOISE CRITERIA CURVES ···························· 66
7. OUTLINES AND DIMENSIONS ······················ 68
8. WIRING DIAGRAM·········································· 75
9. REFRIGERANT SYSTEM DIAGRAM ············· 87
10. PERFORMANCE CURVES ····························· 97
11. ACTUATOR CONTROL ··································115
12. SERVICE FUNCTIONS···································116
13. TROUBLESHOOTING ··································· 120
14. DISASSEMBLY INSTRUCTIONS ·················· 145
15. PARTS LIST··················································· 160
16. RoHS PARTS LIST ········································ 172
17. OPTIONAL PARTS ······················ BACK COVER
Revision A :
• MXZ-3A54VA- E1 and MXZ-4A71VA- E2 have been added.
Quick clean kit has been removed. (Refer to 2.)
• MXZ-2A40VA- E1 and MXZ-2A52VA- E2 have been added.
Revision B :
• MXZ-2A30VA- E1 and MXZ-2A40VA• “Check of HPS” has been corrected.
• RoHS PARTS LIST has been added.
E2
have been added.
Revision C :
• MXZ-2A52VA-
E2
, MXZ-3A54VA- E3 , MXZ-4A71VA- E3 ,
MXZ-4A80VA-
E2
and MXZ-5A100VA-
Revision D:
• MXZ-3A54VA- E4 , and MXZ-4A71VA- E4 have been added.
• The content of pre-heat control (12-3) has been corrected.
• 5. SPECIFICATION has been corrected.
Revision E:
• MXZ-2A30VA- E1 has been added.
• 4. INDOOR UNITS COMBINATION of MXZ-5A100VA-
E2
has been changed.
Revision F:
• MXZ-3A54VA-
E5
and MXZ-4A71VA-
E5
have been added.
E6
and MXZ-4A71VA-
E6
have been added.
Revision G:
• MXZ-3A54VA-
Revision H:
• Indoor units combinations for 42 class have been added.
• MXZ-3A54VA- E7 and MXZ-4A71VA- E7 have been added.
1
TECHNICAL CHANGES
MXZ-A26WV - E1
MXZ-3A54VA - E1
1. Indication of capacity has been changed. (BTU kW)
2. Capacity specification has been changed. (Cooling capacity 7.1kW 5.4kW)
3. Dimensions of unit have been changed. (W900 H900 D320 W840 H710 D330)
4. Combinations of connectable indoor units have been changed.
5. Capacity class of connectable indoor units has been changed.
6. Communication system has been changed.
7. Power supply way has been changed (change to supply to outdoor unit).
8. Compressor has been changed. (TNB220FMCH SNB130FLDH1)
9. High-pressure switch has been removed.
10.Outdoor fan motor has been changed. (PM8H60-UA RC0J60-AA)
11.Evaporation temperature thermistor has been removed.
12.Ambient temperature thermistor has been added.
13.New dip switch has been added to the controller board for "Locking the operation "mode
and "Lowering the operating noise "mode.
14.A Quick Clean Kit has been added.
MXZ-A32WV - E1
MXZ-4A71VA - E1
1. Indication of capacity has been changed. (BTU kW)
2. Capacity specification has been changed. (Cooling capacity 8.0kW 7.1kW)
3. Dimensions of unit have been changed. (W900 H900 D320 W840 H710 D330)
4. Combinations of connectable indoor units have been changed.
5. Capacity class of connectable indoor units has been changed.
6. Communication system has been changed.
7. Power supply way has been changed (change to supply to outdoor unit).
8. Compressor has been changed. (TNB220FMCH SNB130FLDH1)
9. High-pressure switch has been removed.
10. Outdoor fan motor has been changed. (PM8H60-UA RC0J60-AA)
11. Evaporation temperature thermistor has been removed.
12. Ambient temperature thermistor has been added.
13. New dip switch has been added to the controller board for "Locking the operation "mode
and "Lowering the operating noise "mode.
14. A Quick Clean Kit has been added.
2
E1
have been added.
MXZ-A32WV - E1
MXZ-4A80VA - E1
1. Indication of capacity has been changed. (BTU kW)
2. Communication system has been changed.
3. Power supply way has been changed (change to supply to outdoor unit).
4. Evaporation temperature thermistor has been removed.
5. Ambient temperature thermistor has been added.
6. New dip switch has been added to the controller board for "Locking the operation "mode
and "Lowering the operating noise "mode.
7. A Quick Clean Kit has been added.
MXZ-A14WV - E2
MXZ-2A40VA - E1
1. Indication of capacity has been changed. (BTU kW)
2. Dimensions of unit have been changed. (W840 H640 D330 W800 H550
3. Communication system has been changed.
4. Power supply way has been changed (change to supply to outdoor unit).
5. Compressor has been changed. (SNV092FJYH SNB130FKCH)
6. Outdoor fan motor has been changed. (RA6V49 RC0J50-CF)
7. Evaporation temperature thermistor has been removed.
8. Gas pipe temperature thermistor has been removed.
9. Ambient temperature thermistor has been added.
MXZ-A18WV - E2
MXZ-2A52VA - E1
1. Indication of capacity has been changed. (BTU kW)
2. Cooling capacity specification has been changed. (5.4 kW 5.2 kW)
3. Heating capacity specification has been changed. (6.6 kW 6.4 kW)
4. Dimensions of unit have been changed. (W840 H640 D330 W800 H550
5. Communication system has been changed.
6. Power supply way has been changed (change to supply to outdoor unit).
7. Compressor has been changed. (SNV092FJYH SNB130FKCH)
8. Outdoor fan motor has been changed. (RA6V49 RC0J50-CF)
9. Evaporation temperature thermistor has been removed.
10. Gas pipe temperature thermistor has been removed.
11. Ambient temperature thermistor has been added.
MXZ-3A54VA - E1
MXZ-4A71VA - E1
MXZ-3A54VA - E2
MXZ-4A71VA - E2
1. Quick clean kit has been removed.
MXZ-2A30VA - E1
1. New model
MXZ-2A40VA - E1
MXZ-2A40VA - E2
1. Compressor has been changed. (SNB130FKCH
2. Outdoor heat exchanger has been changed.
MXZ-2A52VA - E1
D285)
KNB092FEDH)
MXZ-2A52VA - E2
1. Compressor has been changed. (SNB130FKCH
2. Inverter P.C. board has been changed.
SNB130FKMH)
3
D285)
MXZ-3A54VA - E2
MXZ-3A54VA - E3
1. Compressor has been changed. (SNB130FLDH1
2. Electronic control P.C. board has been changed.
MXZ-4A71VA - E2
MXZ-4A71VA - E3
1. Compressor has been changed. (SNB130FLDH1
2. Electronic control P.C. board has been changed.
MXZ-4A80VA - E1
SNB130FLEH1)
SNB130FLEH1)
MXZ-4A80VA - E2
1. Ball valve has been changed to stop valve.
2. Gas pipe temperature thermistor has been removed.
3. Pre-heat control has been added.
4. Auto line correcting function has been added.
5. Noise filter P.C. board has been changed.
6. Electronic control P.C. board has been changed.
7. Weight has been changed. (70kg 67kg)
MXZ-5A100VA - E1
1. New model
MXZ-3A54VA - E3
1.
2.
3.
4.
5.
MXZ-4A71VA - E3
1.
2.
3.
4.
5.
MXZ-3A54VA - E4
Compressor has been changed. (SNB130FLEH1 SNB130FGBH1)
Electronic control P.C. board has been changed.
Gas pipe temperature thermistor has been removed.
Pre-heat control has been added.
Power board has been changed.
MXZ-4A71VA - E4
Compressor has been changed. (SNB130FLEH1 SNB130FGBH1)
Electronic control P.C. board has been changed.
Gas pipe temperature thermistor has been removed.
Pre-heat control has been added.
Power board has been changed.
MXZ-2A30VA - E1
MXZ-2A30VA - E2
1. Compressor has been changed. (KNB092FEDH
2. Inverter P.C. board has been changed.
MXZ-3A54VA - E4
1.
2.
3.
4.
MXZ-3A54VA - E5
Electronic control P.C. board has been changed.
Noise filter P.C. board has been changed.
Ball valve has been changed to stop valve.
Sub panel has been added.
MXZ-4A71VA - E4
1.
2.
3.
4.
KNB073FGDH)
MXZ-4A71VA - E5
Electronic control P.C. board has been changed.
Noise filter P.C. board has been changed.
Ball valve has been changed to stop valve.
Sub panel has been added.
MXZ-3A54VA - E5
MXZ-4A71VA - E5
MXZ-3A54VA - E6
MXZ-4A71VA - E6
1. Electronic control P.C. board has been changed.
MXZ-3A54VA - E6
MXZ-4A71VA - E6
MXZ-3A54VA - E7
MXZ-4A71VA - E7
1. Electronic control P.C. board has been changed.
2. Compressor has been changed. (SNB130FGBH1
SNB130FGBH1T)
4
INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT
• This room air conditioner adopts HFC refrigerant (R410A) which never destroys the ozone layer.
• Pay particular attention to the following points, though the basic installation procedure is same as that for R22 air conditioners.
As R410A has working pressure approximately 1.6 times as high as that of R22, some special tools and piping parts/
materials are required. Refer to the table below.
Take sufficient care not to allow water and other contaminations to enter the R410A refrigerant during storage and
installation, since it is more susceptible to contaminations than R22.
For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R410A. (Refer to 2. Refrigerant
piping.)
Composition change may occur in R410A since it is a mixed refrigerant. When charging, charge liquid refrigerant to prevent
composition change.
New refrigerant
Previous refrigerant
R410A
R22
Refrigerant
Composition (Ratio)
HFC-32: HFC-125 (50%:50%)
R22 (100%)
Refrigerant handling
Pseudo-azeotropic refrigerant
Single refrigerant
Not included
Included
A1/A1
A1
72.6
86.5
Boiling point (°C)
-51.4
-40.8
Steam pressure [25°C](Mpa)
1.557
0.94
Chlorine
Refrigerant
Safety group (ASHRAE)
Molecular weight
3
Saturated steam density [25°C](Kg/m )
64
44.4
Non combustible
Non combustible
ODP 1
0
0.055
GWP 2
1730
1700
From liquid phase in cylinder
Gas phase
Possible
Possible
Kind
Incompatible oil
Compatible oil
Color
Non
Light yellow
Non
Non
Combustibility
Refrigerant charge method
oil
Refrigeration
Additional charge on leakage
Smell
1 :Ozone Depletion Potential
2 :Global Warming Potential
: based on CFC-11
: based on CO2
5
Compressor
New Specification
Current Specification
The incompatible refrigeration oil easily separates from
Since refrigerant and refrigeration oil are compatible,
refrigerant and is in the upper layer inside the suction muffler. refrigeration oil goes back to the compressor through the
Raising position of the oil back hole enables to back the
lower position oil back hole.
refrigeration oil of the upper layer to flow back to the
compressor.
Suction muffler
Suction muffler
Oil back hole
Compressor
Compressor
Refrigeration oil
Oil back hole
Refrigerant
Refrigeration oil /Refrigerant
NOTE : The unit of pressure has been changed to MPa on the international system of units (SI unit system).
The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/cm2 [Gauge])
Conversion chart of refrigerant temperature and pressure
(MPa [Gauge])
4.0
Saturated liquid pressure
3.5
R410A
3.0
R22
2.5
2.0
1.5
NOTE : The unit of pressure has been changed to MPa on the
international system of units (SI unit system).
1.0
0.5
The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/cm2 [Gauge])
0.0
-0.5
-30 -20 -10
0
10
20
30
40
50
60
(°C)
1. Tools dedicated for the air conditioner with R410A refrigerant
The following tools are required for R410A refrigerant. Some R22 tools can be substituted for R410A tools.
The diameter of the service port on the stop valve in outdoor unit has been changed to prevent any other refrigerant from
being charged into the unit. Cap size has been changed from 7/16 UNF with 20 threads to 1/2 UNF with 20 threads.
R410A tools
Gauge manifold
No
Charge hose
No
R410A has high pressures beyond the measurement range of existing
gauges. Port diameters have been changed to prevent any other refrigerant
from being charged into the unit.
No
Hose material and cap size have been changed to improve the pressure
resistance.
Dedicated for HFC refrigerant.
Yes
6.35 mm and 9.52 mm
Gas leak detector
Torque wrench
Description
Can R22 tools be used?
No
12.7 mm and 15.88 mm
Flare tool
Yes
Clamp bar hole has been enlarged to reinforce the spring strength in the tool.
Flare gauge
Vacuum pump
adapter
Electronic scale for
refrigerant charging
New
Provided for flaring work (to be used with R22 flare tool).
Provided to prevent the back flow of oil. This adapter enables you to use
vacuum pumps.
It is difficult to measure R410A with a charging cylinder because the
refrigerant bubbles due to high pressure and high-speed vaporization
New
New
No: Not Substitutable for R410A
Yes: Substitutable for R410A
6
2. Refrigerant piping
Specifications
Use the copper or copper-alloy seamless pipe for refrigerant that meet the following specifications.
Outside diameter
mm
Insulation material
Wall thickness
6.35
0.8 mm
9.52
0.8 mm
Heat resisting foam plastic
12.7
0.8 mm
Specific gravity 0.045 Thickness 8 mm
15.88
1.0 mm
Flaring work and flare nut
Flaring work for R410A pipe differs from that for R22 pipe.
For details of flaring work, refer to Installation manual “FLARING WORK”.
Dimension of flare nut
Pipe diameter
mm
R410A
R22
6.35
17
17
9.52
22
22
12.7
26
24
15.88
29
27
3. Refrigeration oil
Apply the special refrigeration oil (accessories: packed with indoor unit) to the flare and the union seat surfaces.
4. Air purge
• Do not discharge the refrigerant into the atmosphere.
Take care not to discharge refrigerant into the atmosphere during installation, reinstallation, or repairs to the refrigerant
circuit.
• Use the vacuum pump for air purging for the purpose of environmental protection.
5. Additional charge
For additional charging, charge the refrigerant from liquid phase of the gas cylinder.
If the refrigerant is charged from the gas phase, composition change may occur in the refrigerant inside the cylinder and the
outdoor unit. In this case, ability of the refrigeration cycle decreases or normal operation can be impossible. However,
charging the liquid refrigerant all at once may cause the compressor to be locked. Thus, charge the refrigerant slowly.
Union
Stop valve
Indoor unit
Liquid pipe
Gas pipe
Refrigerant gas
cylinder
operating valve
Outdoor unit
Service port
Gauge manifold
valve (for R410A)
Charge hose (for R410A)
Refrigerant gas cylinder
for R410A with siphon
Refrigerant (liquid)
Electronic scale for refrigerant charging
7
2
PART NAMES AND FUNCTIONS
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
MXZ-3A54VA- E1 ,
MXZ-4A71VA- E1 ,
,
E2 ,
E2
,
E3 ,
E3
E4
E4
Air inlet
(Back and side)
Air inlet
(Back and side)
Piping
Drain hose
Air outlet
Air outlet
Drain outlet
Drain outlet
MXZ-3A54VA- E5 ,
MXZ-4A71VA- E5 ,
E6
E6
,
,
E7
E7
Air inlet
(Back and side)
Air outlet
Drain outlet
8
MXZ-4A80VA-
MXZ-4A80VA- E2
MXZ-5A100VA
E1
Air inlet
(Back and side)
Air inlet
(Back and side)
Air outlet
Air outlet
Drain outlet
Drain outlet
ACCESSORIES
MXZ-3A54VA - E2
MXZ-4A71VA - E2
MXZ-4A80VA
MXZ-5A100VA
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
MXZ-3A54VA - E1
MXZ-4A71VA - E1
Drain socket
1
1
1
Drain cap
-
2
2
Quick Clean kit
-
1
-
9
, E3 , E4 , E5 , E6 , E7
, E3 , E4 , E5 , E6 , E7
3
INDOOR/OUTDOOR CORRESPONDENCE TABLE
MXZ-2A30VA
MXZ-4A71VA
MXZ-4A71VA
22+22
22+25
25+25
22+22
22+25
22+35
22+42
22+50
22+60
25+25
25+35
25+42
25+50
25+60
35+35
35+42
35+50
35+60
42+42
42+50
42+60
50+50
50+60
60+60
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+35+35
22+35+42
22+35+50
22+35+60
22+42+42
22+42+50
22+42+60
22+50+50
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+35+35
25+35+42
25+35+50
25+35+60
25+42+42
25+42+50
25+50+50
35+35+35
35+35+42
35+35+50
35+42+42
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+35+35
22+22+35+42
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+35+35
22+25+35+42
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+35+35
Indoor units
combination
MXZ-2A40VA
22+22
22+25
22+35
25+25
25+35
22+22
22+25
22+35
25+25
25+35
35+35
Indoor units combination
MXZ-3A54VA
22+22
22+25
22+35
22+42
22+50
25+25
25+35
25+42
25+50
35+35
35+42
35+50
42+42
42+50
50+50
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+25+25
22+25+35
22+25+42
22+25+50
22+35+35
22+35+42
25+25+25
25+25+35
25+25+42
25+25+50
25+35+35
Indoor units combination
Indoor units
combination
MXZ-2A52VA
Indoor units combination
Indoor units
combination
There is no combination other than this table.
10
MXZ-4A80VA
MXZ-4A80VA
22+22
22+25
22+35
22+42
22+50
22+60
22+71
25+25
25+35
25+42
25+50
25+60
25+71
35+35
35+42
35+50
35+60
35+71
42+42
42+50
42+60
42+71
50+50
50+60
50+71
60+60
60+71
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+22+71
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+25+71
22+35+35
22+35+42
22+35+50
22+35+60
22+35+71
22+42+42
22+42+50
22+42+60
22+42+71
22+50+50
22+50+60
22+50+71
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+25+71
25+35+35
25+35+42
25+35+50
25+35+60
25+35+71
25+42+42
25+42+50
25+42+60
25+42+71
25+50+50
25+50+60
35+35+35
35+35+42
35+35+50
35+35+60
35+35+71
35+42+42
35+42+50
35+42+60
35+50+50
35+50+60
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+22+60
22+22+22+71
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+25+60
22+22+25+71
22+22+35+35
22+22+35+42
22+22+35+50
22+22+35+60
22+22+42+42
22+22+42+50
22+22+50+50
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+25+60
22+25+35+35
22+25+35+42
22+25+35+50
22+25+35+60
22+35+35+35
22+35+35+42
22+35+35+50
22+35+42+42
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+42
25+25+35+50
25+35+35+35
25+35+35+42
35+35+35+35
Indoor units combination
MXZ-4A80VA
Indoor units combination
Indoor units combination
There is no combination other than this table.
11
MXZ-5A100VA
MXZ-5A100VA
22+60+60
22+60+71
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+25+71
25+35+35
25+35+42
25+35+50
25+35+60
25+35+71
25+42+42
25+42+50
25+42+60
25+42+71
25+50+50
25+50+60
25+50+71
25+60+60
25+60+71
35+35+35
35+35+42
35+35+50
35+35+60
35+35+71
35+42+42
35+42+50
35+42+60
35+42+71
35+50+50
35+50+60
35+50+71
35+60+60
35+60+71
42+42+42
42+42+50
42+42+60
42+42+71
42+50+50
42+50+60
42+50+71
42+60+60
50+50+50
50+50+60
50+50+71
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+22+60
22+22+22+71
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+25+60
22+22+25+71
22+22+35+35
22+22+35+42
22+22+35+50
22+22+35+60
22+22+35+71
22+22+42+42
22+22+42+50
22+22+42+60
22+22+42+71
22+22+50+50
22+22+50+60
22+22+50+71
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+25+60
22+25+25+71
22+25+35+35
22+25+35+42
22+25+35+50
22+25+35+60
22+25+35+71
22+25+42+42
22+25+42+50
22+25+42+60
22+25+42+71
22+25+50+50
22+25+50+60
22+25+50+71
22+35+35+35
22+35+35+42
22+35+35+50
22+35+35+60
22+35+35+71
22+35+42+42
22+35+42+50
22+35+42+60
22+35+42+71
22+35+50+50
22+35+50+60
22+42+42+42
22+42+42+50
22+42+42+60
22+42+50+50
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+25+60
25+25+25+71
25+25+35+35
25+25+35+42
25+25+35+50
25+25+35+60
25+25+35+71
25+25+42+42
25+25+42+50
25+25+42+60
25+25+42+71
25+25+50+50
25+25+50+60
25+25+50+71
25+35+35+35
25+35+35+42
25+35+35+50
25+35+35+60
25+35+35+71
25+35+42+42
25+35+42+50
25+35+42+60
25+42+42+42
25+42+42+50
25+42+42+60
25+42+50+50
35+35+35+35
35+35+35+42
35+35+35+50
35+35+35+60
35+35+42+42
35+35+42+50
35+42+42+42
35+42+42+50
42+42+42+42
22+22+22+22+22
22+22+22+22+25
22+22+22+22+35
22+22+22+22+42
22+22+22+22+50
22+22+22+22+60
22+22+22+22+71
22+22+22+25+25
22+22+22+25+35
22+22+22+25+42
22+22+22+25+50
22+22+22+25+60
22+22+22+25+71
22+22+22+35+35
22+22+22+35+42
12
Indoor units combination
MXZ-5A100VA
22+22
22+25
22+35
22+42
22+50
22+60
22+71
25+25
25+35
25+42
25+50
25+60
25+71
35+35
35+42
35+50
35+60
35+71
42+42
42+50
42+60
42+71
50+50
50+60
50+71
60+60
60+71
71+71
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+22+71
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+25+71
22+35+35
22+35+42
22+35+50
22+35+60
22+35+71
22+42+42
22+42+50
22+42+60
22+42+71
22+50+50
22+50+60
22+50+71
Indoor units combination
MXZ-5A100VA
Indoor units combination
Indoor units combination
There is no combination other than this table.
There is no combination other than this table.
Indoor units combination
MXZ-5A100VA
MXZ-5A100VA
Indoor units
combination
22+22+22+35+50
22+22+22+35+60
22+22+22+35+71
22+22+22+42+42
22+22+22+42+50
22+22+22+42+60
22+22+25+25+25
22+22+25+25+35
22+22+25+25+42
22+22+25+25+50
22+22+25+25+60
22+22+25+25+71
22+22+25+35+35
22+22+25+35+42
22+22+25+35+50
22+22+25+35+60
22+22+25+42+42
22+22+25+42+50
22+22+25+42+60
22+22+35+35+35
22+22+35+35+42
22+22+35+35+50
22+22+35+42+42
22+22+35+42+50
22+22+42+42+42
22+25+25+25+25
22+25+25+25+35
22+25+25+25+42
22+25+25+25+50
22+25+25+25+60
22+25+25+25+71
22+25+25+35+35
22+25+25+35+42
22+25+25+35+50
22+25+25+35+60
22+25+25+42+42
22+25+25+42+50
22+25+35+35+35
22+25+35+35+42
22+25+35+35+50
22+25+35+42+42
22+35+35+35+35
22+35+35+35+42
25+25+25+25+25
25+25+25+25+35
25+25+25+25+42
25+25+25+25+50
25+25+25+25+60
25+25+25+25+71
25+25+25+35+35
25+25+25+35+42
25+25+25+35+50
25+25+25+35+60
25+25+25+42+42
25+25+25+42+50
25+25+35+35+35
25+25+35+35+42
25+25+35+35+50
25+25+35+42+42
13
4
INDOOR UNITS COMBINATION
MXZ-2A30VA
Cooling capacity (kW)
Indoor units
combination
Unit A
Unit B
22
2.20
–
25
2.50
–
22+22
1.40
1.40
22+25
1.40
1.50
25+25
1.50
1.50
Total
2.2
(0.9 - 3.0)
2.5
(0.9 - 3.3)
2.8
( 1.1 - 3.8)
2.9
(1.1 - 3.9)
3.0
(1.1 - 4.0)
Heating capacity (kW)
Indoor units
combination
Unit A
Unit B
22
3.30
–
25
3.60
–
22+22
1.90
1.90
22+25
1.90
2.00
25+25
2.00
2.00
Total
3.3
(0.9 - 4.0)
3.6
(0.9 - 4.5)
3.8
(1.0 - 4.3)
3.9
(1.0 - 4.4)
4.0
(1.0 - 4.5)
14
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Power
Current
power consumption
factor
(A)
(kW)
(%)
0.430
2.08
90
(0.120 - 0.620)
0.490
2.37
90
(0.120 - 0.690)
0.540
2.61
90
(0.250 - 0.970)
0.565
2.73
90
(0.250 - 1.020)
0.595
2.87
90
(0.250 - 1.070)
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Power
Current
power consumption
factor
(A)
(kW)
(%)
0.670
3.24
90
(0.110 - 0.910)
0.730
3.53
90
(0.110 - 1.050)
0.705
3.41
90
(0.200 - 0.770)
0.725
3.50
90
( 0.200 - 0.795)
0.745
3.60
90
(0.200 - 0.810)
MXZ-2A40VA
Cooling capacity (kW)
Indoor units
combination
Unit A
Unit B
22
2.20
–
25
2.50
–
35
3.50
–
22+22
1.90
1.90
22+25
1.83
2.07
22+35
1.51
2.39
25+25
1.95
1.95
25+35
1.67
2.33
Total
2.2
(0.9 - 3.0)
2.5
(0.9 - 3.3)
3.5
(0.9 - 4.0)
3.8
( 1.1 - 4.3)
3.9
(1.1 - 4.3)
3.9
(1.1 - 4.4)
3.9
(1.1 - 4.4)
4.0
(1.1 - 4.5)
Heating capacity (kW)
Indoor units
combination
Unit A
Unit B
22
3.30
–
25
3.60
–
35
4.00
–
22+22
2.20
2.20
22+25
2.06
2.34
22+35
1.70
2.70
25+25
2.20
2.20
25+35
1.85
2.65
Total
3.3
(0.9 - 4.0)
3.6
(0.9 - 4.5)
4.0
(0.9 - 4.8)
4.4
(1.0 - 4.8)
4.4
(1.0 - 4.8)
4.4
(1.0 - 4.9)
4.4
(1.0 - 4.9)
4.5
(1.0 - 5.0)
15
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Power
Current
power consumption
factor
(A)
(kW)
(%)
0.430
2.08
90
(0.120 - 0.620)
0.490
2.37
90
(0.120 - 0.690)
0.730
3.53
90
(0.120 - 0.900)
0.830
3.80
95
(0.250 - 1.110)
0.970
4.44
95
(0.250 - 1.110)
0.970
4.44
95
(0.250 - 1.130)
0.970
4.44
95
(0.250 - 1.130)
1.045
4.78
95
(0.250 - 1.170)
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Power
Current
power consumption
factor
(A)
(kW)
(%)
0.670
90
3.24
(0.110 - 0.910)
0.730
3.53
90
(0.110 - 1.050)
0.870
4.20
90
(0.110 - 1.150)
0.910
4.16
95
(0.200 - 1.010)
0.910
4.16
95
( 0.200 - 1.010)
0.910
4.16
95
(0.200 - 1.030)
0.910
4.16
95
(0.200 - 1.030)
0.945
4.32
95
(0.200 - 1.050)
MXZ-2A52VA
Cooling capacity (kW)
Indoor units
combination
Unit A
Unit B
22
2.20
–
25
2.50
–
35
3.50
–
22+22
2.20
2.20
22+25
2.20
2.50
22+35
1.93
3.07
25+25
2.50
2.50
25+35
2.13
2.97
35+35
2.60
2.60
Total
2.2
(0.9 - 3.0)
2.5
(0.9 - 3.3)
3.5
(0.9 - 4.0)
4.4
(1.1 - 5.3)
4.7
(1.1 - 5.4)
5.0
(1.1 - 5.6)
5.0
(1.1 - 5.6)
5.1
(1.1 - 5.8)
5.2
(1.1 - 6.0)
Heating capacity (kW)
Indoor units
combination
Unit A
Unit B
22
3.30
–
25
3.60
–
35
4.00
–
22+22
3.05
3.05
22+25
2.90
3.30
22+35
2.43
3.87
25+25
3.15
3.15
25+35
2.63
3.67
35+35
3.20
3.20
Total
3.3
( 0.9 - 4.0)
3.6
(0.9 - 4.5)
4.0
(0.9 - 4.8)
6.1
(1.0 - 6.7)
6.2
(1.0 - 6.8)
6.3
(1.0 - 7.0)
6.3
(1.0 - 7.0)
6.3
(1.0 - 7.1)
6.4
(1.0 - 7.2)
16
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Power
Current
power consumption
factor
(A)
(kW)
(%)
0.430
2.08
90
(0.120 - 0.620)
0.490
2.37
90
(0.120 - 0.690)
0.730
3.53
90
(0.120 - 0.900)
1.130
96
5.12
(0.250-1.510)
1.250
96
5.66
(0.250 - 1.560)
1.400
6.28
97
(0.250 - 1.650)
1.400
6.28
97
(0.250 - 1.650)
1.450
6.50
97
(0.250 - 1.740)
1.505
97
6.75
(0.250 - 1.830)
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Power
Current
power consumption
factor
(A)
(kW)
(%)
0.670
90
3.24
(0.110 - 0.910)
0.730
3.53
90
(0.110 - 1.050)
0.870
4.20
90
(0.110 - 1.150)
1.550
97
6.95
(0.200 - 1.730)
1.600
97
7.17
(0.200 - 1.750)
1.650
7.40
97
(0.200 - 1.790)
1.650
7.40
97
(0.200 - 1.790)
1.650
7.40
97
(0.200 - 1.820)
1.705
7.64
97
(0.200 - 1.840)
MXZ-3A54VA
Indoor units
combination
22
25
35
42
50
22+22
22+25
22+35
22+42
22+50
25+25
25+35
25+42
25+50
35+35
35+42
35+50
42+42
42+50
50+50
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+25+25
NOTE: Electrical data is for outdoor unit only.
Cooling capacity (kW)
Unit A
Unit B
Unit C
2.2
-
-
Total
( 1.4
2.5
-
-
3.5
-
-
( 1.4
( 1.5
4.2
-
( 1.6
5.0
-
( 1.6
2.2
2.2
( 2.0
2.2
2.5
( 2.0
2.08
3.32
( 2.0
1.86
3.54
( 2.0
1.65
3.75
-
2.5
2.5
-
( 2.0
( 2.0
2.25
3.15
( 2.0
2.01
3.39
( 2.0
1.8
3.6
( 2.0
2.7
2.7
( 2.0
2.4
3.0
( 2.0
2.22
3.18
( 2.0
2.7
2.7
-
2.47
2.93
-
( 2.0
( 2.1
2.7
2.7
( 2.1
1.8
1.8
1.8
( 2.9
1.72
1.72
1.96
( 2.9
1.5
1.5
2.4
( 2.9
1.38
1.38
2.64
( 2.9
1.26
1.26
2.88
( 2.9
1.64
1.88
1.88
( 2.9
2.2
2.5
3.5
4.2
5.0
4.4
4.7
5.4
5.4
5.4
5.0
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
-
3.0 ) (
3.3 ) (
4.3 ) (
5.0 ) (
5.6 ) (
5.4 ) (
5.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.0 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
17
Outdoor unit
power consumption
(kW)
0.590
0.420 - 0.740
0.660
0.420 - 0.830
0.950
0.430 - 1.180
1.220
0.450 - 1.420
1.500
0.480 - 1.660
1.180
0.540 - 1.450
1.300
0.540 - 1.630
1.600
0.540 - 2.550
1.590
0.540 - 2.490
1.580
0.550 - 2.440
1.420
0.540 - 1.750
1.600
0.540 - 2.550
1.590
0.540 - 2.490
1.580
0.550 - 2.440
1.600
0.540 - 2.550
1.560
0.540 - 2.490
1.530
0.550 - 2.440
1.530
0.550 - 2.440
1.540
0.550 - 2.390
1.550
0.560 - 2.340
1.295
0.670 - 1.770
1.295
0.670 - 1.770
1.295
0.670 - 1.770
1.280
0.670 - 1.780
1.265
0.680 - 1.790
1.295
0.670 - 1.770
2.59
Power
factor
(%)
99
2.90
99
4.17
99
5.36
99
6.59
99
5.18
99
5.71
99
7.03
99
6.98
99
6.94
99
6.24
99
7.03
99
6.98
99
6.94
99
7.03
99
6.85
99
6.72
99
6.72
99
6.76
99
6.81
99
5.69
99
5.69
99
5.69
99
5.62
99
5.56
99
5.69
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
MXZ-3A54VA
Indoor units
combination
22+25+35
22+25+42
22+25+50
22+35+35
22+35+42
25+25+25
25+25+35
25+25+42
25+25+50
25+35+35
NOTE: Electrical data is for outdoor unit only.
Cooling capacity (kW)
Unit A
Unit B
Unit C
1.45
1.65
2.3
Total
( 2.9
1.33
1.52
2.55
1.23
1.39
2.78
( 2.9
( 2.9
1.3
2.05
2.05
( 2.9
1.2
1.91
2.29
( 2.9
1.8
1.8
1.8
( 2.9
1.59
1.59
2.22
( 2.9
1.47
1.47
2.46
( 2.9
1.35
1.35
2.7
( 2.9
1.42
1.99
1.99
( 2.9
18
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
-
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
6.8 ) (
Outdoor unit
power consumption
(kW)
1.295
0.670 - 1.770
1.280
0.670 - 1.780
1.265
0.680 - 1.790
1.295
0.670 - 1.770
1.290
0.670 - 1.770
1.295
0.670 - 1.770
1.295
0.670 - 1.770
1.280
0.670 - 1.780
1.265
0.680 - 1.790
1.295
0.670 - 1.770
5.69
Power
factor
(%)
99
5.62
99
5.56
99
5.69
99
5.67
99
5.69
99
5.69
99
5.62
99
5.56
99
5.69
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
MXZ-3A54VA
Indoor units
combination
22
25
35
42
50
22+22
22+25
22+35
22+42
22+50
25+25
25+35
25+42
25+50
35+35
35+42
35+50
42+42
42+50
50+50
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+25+25
NOTE: Electrical data is for outdoor unit only.
Heating capacity (kW)
Unit A
Unit B
Unit C
3.3
-
-
3.6
-
-
4.0
-
-
5.4
6.8
3.3
3.18
2.62
2.34
3.3
3.62
4.18
4.46
-
2.08
4.72
-
3.4
3.4
-
2.83
2.54
2.27
3.4
3.09
2.8
3.97
4.26
4.53
3.4
3.71
4.0
-
3.4
3.4
-
3.1
3.7
-
3.4
2.27
2.17
1.89
1.74
1.59
2.08
3.4
2.27
2.17
1.89
1.74
1.59
2.36
2.27
2.46
3.02
3.32
3.62
2.36
Total
3.3
( 1.2 3.6
( 1.2 4.0
( 1.2 5.4
( 1.3 6.8
( 1.4 6.6
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.8 6.8
( 1.9 6.8
( 1.9 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 -
4.2 ) (
4.5 ) (
4.8 ) (
6.5 ) (
8.2 ) (
7.2 ) (
8.7 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
19
Outdoor unit
power consumption
(kW)
0.820
0.380 - 1.090
0.910
0.380 - 1.190
1.040
0.380 - 1.300
1.400
0.370 - 1.800
1.770
0.370 - 2.300
1.500
0.410 - 1.710
1.580
0.410 - 2.350
1.580
0.410 - 2.390
1.510
0.400 - 2.300
1.440
0.390 - 2.220
1.580
0.410 - 2.390
1.580
0.410 - 2.390
1.510
0.400 - 2.300
1.440
0.390 - 2.220
1.580
0.410 - 2.390
1.510
0.410 - 2.300
1.440
0.410 - 2.220
1.440
0.410 - 2.220
1.410
0.380 - 2.130
1.390
0.360 - 2.040
1.455
0.500 - 2.120
1.455
0.500 - 2.120
1.455
0.500 - 2.120
1.380
0.490 - 2.040
1.310
0.480 - 1.960
1.455
0.500 - 2.120
3.60
Power
factor
(%)
99
4.00
99
4.57
99
6.15
99
7.77
99
6.59
99
6.94
99
6.94
99
6.63
99
6.32
99
6.94
99
6.94
99
6.63
99
6.32
99
6.94
99
6.63
99
6.32
99
6.32
99
6.19
99
6.10
99
6.39
99
6.39
99
6.39
99
6.06
99
5.75
99
6.39
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
MXZ-3A54VA
Indoor units
combination
22+25+35
22+25+42
22+25+50
22+35+35
22+35+42
25+25+25
25+25+35
25+25+42
25+25+50
25+35+35
NOTE: Electrical data is for outdoor unit only.
Heating capacity (kW)
Unit A
1.83
Unit B
2.07
Unit C
2.9
1.68
1.91
3.21
1.54
1.75
3.51
1.62
1.51
2.27
2.0
1.85
1.7
1.78
2.59
2.41
2.27
2.0
1.85
1.7
2.51
2.59
2.88
2.27
2.8
3.1
3.4
2.51
Total
6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 6.8
( 2.6 -
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
9.0 ) (
20
Outdoor unit
power consumption
(kW)
1.455
0.500 - 2.120
1.380
0.490 - 2.040
1.310
0.480 - 1.960
1.455
0.500 - 2.120
1.455
0.500 - 2.120
1.455
0.500 - 2.120
1.455
0.500 - 2.120
1.380
0.490 - 2.040
1.310
0.480 - 1.960
1.455
0.460 - 2.120
6.39
Power
factor
(%)
99
6.06
99
5.75
99
6.39
99
6.39
99
6.39
99
6.39
99
6.06
99
5.75
99
6.39
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
MXZ-4A71VA
Indoor units
combination
22
25
35
42
50
60
22+22
22+25
22+35
22+42
22+50
22+60
25+25
25+35
25+42
25+50
25+60
35+35
35+42
35+50
35+60
42+42
42+50
42+60
50+50
50+60
NOTE: Electrical data is for outdoor unit only.
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
2.2
-
-
-
Total
( 1.4
2.5
-
-
-
3.5
-
-
-
( 1.4
( 1.5
4.2
-
-
( 1.6
5.0
-
-
( 1.6
6.0
-
-
( 1.6
2.2
2.2
-
( 2.0
2.2
2.5
-
( 2.0
2.2
3.5
-
( 2.0
2.2
4.2
-
-
2.08
4.72
-
-
( 2.0
( 2.0
1.82
4.98
-
( 2.0
2.5
2.5
-
( 2.0
2.5
3.5
-
( 2.0
2.5
4.2
-
( 2.0
2.27
4.53
-
( 2.0
2.0
4.8
-
( 2.0
3.4
3.4
-
-
3.09
3.71
-
-
( 2.0
( 2.0
2.8
4.0
-
( 2.0
2.51
4.29
-
( 2.0
3.4
3.4
-
( 2.0
3.1
3.7
-
( 2.0
2.8
4.0
-
( 2.0
3.4
3.4
-
( 2.1
3.09
3.71
-
( 2.1
21
2.2
2.5
3.5
4.2
5.0
6.0
4.4
4.7
5.7
6.4
6.8
6.8
5.0
6.0
6.7
6.8
6.8
6.8
6.8
6.8
6.8
6.8
6.8
6.8
6.8
6.8
-
3.0
) (
3.3
) (
4.3
) (
5.0
) (
5.6
) (
6.6
) (
5.4
) (
5.8
) (
6.6
) (
7.1
) (
7.1
) (
7.1
) (
6.0
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
7.1
) (
Outdoor unit
power consumption
(kW)
0.590
0.420 - 0.740
0.660
0.420 - 0.830
0.950
0.430 - 1.180
1.220
0.450 - 1.420
1.500
0.480 - 1.660
2.110
0.480 - 2.290
1.180
0.540 - 1.450
1.300
0.540 - 1.630
1.800
0.540 - 2.100
2.120
0.540 - 2.540
2.440
0.550 - 2.570
2.460
0.550 - 2.600
1.420
0.540 - 1.750
2.010
0.540 - 2.540
2.220
0.540 - 2.560
2.440
0.550 - 2.590
2.460
0.550 - 2.600
2.570
0.540 - 2.600
2.500
0.540 - 2.600
2.440
0.550 - 2.600
2.460
0.550 - 2.610
2.500
0.540 - 2.600
2.440
0.550 - 2.600
2.460
0.550 - 2.610
2.380
0.560 - 2.610
2.400
0.570 - 2.620
2.59
Power
factor
(%)
99
2.90
99
4.17
99
5.36
99
6.59
99
9.27
99
5.18
99
5.71
99
7.91
99
9.31
99
10.72
99
10.80
99
6.24
99
8.83
99
9.75
99
10.72
99
10.80
99
11.29
99
10.98
99
10.72
99
10.80
99
10.98
99
10.72
99
10.80
99
10.45
99
10.54
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
60+60
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+35+35
22+35+42
22+35+50
22+35+60
22+42+42
22+42+50
22+42+60
22+50+50
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+35+35
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
3.4
3.4
-
-
2.2
2.2
2.2
-
6.8
6.6
6.9
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
-
( 2.1
( 2.9
2.2
2.2
2.5
( 2.9
1.98
1.98
3.14
-
1.81
1.81
3.48
-
( 2.9
( 2.9
1.66
1.66
3.78
( 2.9
1.5
1.5
4.1
( 2.9
2.16
2.47
2.47
( 2.9
1.91
2.16
3.03
-
1.76
1.99
3.35
-
( 2.9
( 2.9
1.61
1.83
3.66
( 2.9
1.46
1.66
3.98
-
1.7
2.7
2.7
-
( 2.9
( 2.9
1.58
2.51
3.01
( 2.9
1.46
2.32
3.32
( 2.9
1.34
2.12
3.64
( 2.9
1.5
2.8
2.8
-
1.4
2.6
3.1
-
( 2.9
( 2.9
1.3
2.4
3.4
( 2.9
1.28
2.91
2.91
-
2.36
2.36
2.36
-
( 2.9
( 2.9
2.09
2.09
2.92
( 2.9
1.93
1.93
3.24
( 2.9
1.78
1.78
3.54
( 2.9
1.61
1.61
3.88
-
1.86
2.62
2.62
-
( 2.9
( 2.9
22
7.1
) (
8.1
) (
8.3
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
Outdoor unit
power consumption
(kW)
2.420
0.580 - 2.630
1.750
0.670 - 2.390
1.880
0.670 - 2.510
1.990
0.670 - 2.690
1.970
0.670 - 2.700
1.960
0.680 - 2.720
1.950
0.680 - 2.740
1.990
0.670 - 2.690
1.990
0.670 - 2.690
1.970
0.670 - 2.700
1.960
0.680 - 2.720
1.950
0.680 - 2.740
1.990
0.670 - 2.690
1.970
0.670 - 2.700
1.960
0.680 - 2.720
1.950
0.680 - 2.740
1.970
0.670 - 2.700
1.960
0.680 - 2.720
1.950
0.680 - 2.740
1.940
0.690 - 2.770
1.990
0.670 - 2.690
1.99
0.670 - 2.690
1.97
0.670 - 2.700
1.96
0.680 - 2.720
1.95
0.680 - 2.740
1.99
0.670 - 2.690
10.63
Power
factor
(%)
99
7.69
99
8.26
99
8.74
99
8.65
99
8.61
99
8.56
99
8.74
99
8.74
99
8.65
99
8.61
99
8.56
99
8.74
99
8.65
99
8.61
99
8.56
99
8.65
99
8.61
99
8.56
99
8.52
99
8.74
99
8.74
99
8.65
99
8.61
99
8.56
99
8.74
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
25+35+42
25+35+50
25+35+60
25+42+42
25+42+50
25+50+50
35+35+35
35+35+42
35+35+50
35+42+42
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+35+35
22+22+35+42
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+35+35
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
1.74
2.44
2.92
-
1.61
2.26
3.23
-
Total
(
(
1.48
2.07
3.55
(
1.62
2.74
2.74
-
1.52
2.55
3.03
-
(
(
1.42
2.84
2.84
(
2.36
2.36
2.36
(
2.22
2.22
2.66
(
2.07
2.07
2.96
-
1.48
2.07
3.55
-
(
(
1.77
1.77
1.77
1.77
(
1.72
1.72
1.72
1.94
1.55
1.55
1.55
2.45
(
(
1.44
1.44
1.44
2.78
(
1.35
1.35
1.35
3.05
(
1.66
1.66
1.89
1.89
(
1.50
1.50
1.71
2.39
1.40
1.40
1.59
2.71
(
(
1.31
1.31
1.50
2.98
(
1.37
1.37
2.18
2.18
1.29
1.29
2.05
2.47
(
(
1.61
1.83
1.83
1.83
(
1.46
1.66
1.66
2.32
(
1.36
1.55
1.55
2.64
(
1.29
1.45
1.45
2.91
1.34
1.52
2.12
2.12
(
(
7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
2.9 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 7.1
3.7 -
23
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.5
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
Outdoor unit
power consumption
(kW)
1.97
0.670 - 2.700
1.96
0.680 - 2.720
1.95
0.680 - 2.740
1.97
0.670 - 2.700
1.96
0.680 - 2.720
1.94
0.690 - 2.770
1.99
0.670 - 2.690
1.97
0.670 - 2.700
1.96
0.680 - 2.720
1.97
0.670 - 2.700
1.93
0.800 - 2.750
1.93
0.800 - 2.750
1.93
0.800 - 2.750
1.92
0.800 - 2.760
1.91
0.810 - 2.780
1.93
0.800 - 2.750
1.93
0.800 - 2.750
1.92
0.800 - 2.760
1.91
0.810 - 2.780
1.93
0.800 - 2.750
1.92
0.800 - 2.760
1.93
0.800 - 2.750
1.93
0.800 - 2.750
1.92
0.800 - 2.760
1.91
0.810 - 2.780
1.93
0.800 - 2.750
8.65
Power
factor
(%)
99
8.61
99
8.56
99
8.65
99
8.61
99
8.52
99
8.74
99
8.65
99
8.61
99
8.65
99
8.48
99
8.48
99
8.48
99
8.43
99
8.39
99
8.48
99
8.48
99
8.43
99
8.39
99
8.48
99
8.43
99
8.48
99
8.48
99
8.43
99
8.39
99
8.48
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+25+35+42
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+35+35
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
1.26
1.43
2.00
2.41
1.77
1.77
1.77
1.77
7.1
7.1
7.1
7.1
7.1
7.1
-
( 3.7
( 3.7
1.61
1.61
1.61
2.27
( 3.7
1.51
1.51
1.51
2.57
1.42
1.42
1.42
2.84
( 3.7
( 3.7
1.48
1.48
2.07
2.07
( 3.7
24
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
Outdoor unit
power consumption
(kW)
1.92
0.800 - 2.760
1.93
0.800 - 2.750
1.93
0.800 - 2.750
1.92
0.800 - 2.760
1.91
0.810 - 2.780
1.93
0.800 - 2.750
8.43
Power
factor
(%)
99
8.48
99
8.48
99
8.43
99
8.39
99
8.48
99
Current
(A)
)
)
)
)
)
)
Indoor units
combination
22
25
35
42
50
60
22+22
22+25
22+35
22+42
22+50
22+60
25+25
25+35
25+42
25+50
25+60
35+35
35+42
35+50
35+60
42+42
42+50
42+60
50+50
50+60
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
3.3
-
-
-
3.6
-
-
-
3.3
3.6
4.0
5.4
7.2
7.9
6.6
6.9
7.3
8.6
8.6
8.6
7.2
7.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
-
4.0
-
-
-
-
-
7.2
-
-
-
3.3
3.23
3.3
3.67
-
-
3.26
5.34
-
-
6.29
-
-
3.6
3.6
-
-
3.21
2.87
4.43
5.39
5.73
-
-
4.3
4.3
-
-
5.06
-
-
3.17
5.43
-
-
3.9
3.5
4.3
4.7
5.1
-
1.4
(
1.4
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
-
3.54
4.3
(
-
-
-
1.3
-
6.07
4.69
(
-
2.53
3.91
1.2
-
2.31
3.17
(
-
-
-
1.2
-
4.48
5.97
(
-
2.82
2.63
1.2
-
5.4
7.9
(
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
-
4.3
4.3
-
-
3.91
4.69
-
-
(
1.9
(
1.9
25
4.2
) (
4.5
) (
4.8
) (
6.5
) (
8.2
) (
8.6
) (
7.2
) (
8.7
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
Outdoor unit
power consumption
(kW)
0.820
0.380 - 1.090
0.910
0.380 - 1.190
1.040
0.380 - 1.300
1.460
0.370 - 1.800
1.880
0.370 - 2.300
2.150
0.360 - 2.410
1.500
0.410 - 1.710
1.610
0.410 - 2.350
1.770
0.410 - 2.390
1.940
0.400 - 2.300
2.110
0.390 - 2.220
2.090
0.380 - 2.220
1.710
0.410 - 2.390
1.890
0.410 - 2.390
2.000
0.400 - 2.300
2.110
0.390 - 2.220
2.090
0.380 - 2.220
2.030
0.410 - 2.390
2.070
0.400 - 2.300
2.110
0.390 - 2.220
2.090
0.380 - 2.220
2.090
0.400 - 2.300
2.110
0.390 - 2.220
2.090
0.380 - 2.220
1.820
0.360 - 2.040
1.820
0.360 - 2.040
3.60
Power
factor
(%)
99
4.00
99
4.57
99
6.41
99
8.26
99
9.44
99
6.59
99
7.07
99
7.77
99
8.52
99
9.27
99
9.18
99
7.51
99
8.30
99
8.78
99
9.27
99
9.18
99
8.92
99
9.09
99
9.27
99
9.18
99
9.18
99
9.27
99
9.18
99
7.99
99
7.99
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
60+60
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+35+35
22+35+42
22+35+50
22+35+60
22+42+42
22+42+50
22+42+60
22+50+50
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+35+35
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
4.3
4.3
-
-
2.87
2.87
2.87
-
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
-
2.74
2.74
3.12
2.39
3.82
-
2.2
2.2
4.2
-
1.82
2.62
2.01
1.82
2.99
4.58
4.96
2.99
-
2.12
2.42
4.06
-
2.01
4.82
-
2.06
3.27
3.27
-
1.77
1.62
3.04
2.81
2.57
3.65
4.02
4.41
-
1.66
3.17
3.77
-
3.52
3.52
-
2.86
2.86
2.86
-
2.33
2.15
2.53
2.33
2.15
3.54
3.94
4.30
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
-
1.56
2.53
(
-
3.4
4.2
2.6
-
3.4
2.9
(
-
1.8
1.5
2.6
-
1.77
1.91
(
-
3.67
4.43
2.6
-
2.62
2.22
(
-
2.31
1.95
1.9
-
2.39
2.01
(
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
-
1.95
1.95
4.68
-
2.26
3.17
3.17
-
(
2.6
(
2.6
26
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
Outdoor unit
power consumption
(kW)
1.820
0.360 - 2.040
2.020
0.500 - 2.120
2.020
0.500 - 2.120
2.020
0.500 - 2.120
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.850
0.480 - 1.960
2.020
0.500 - 2.120
2.020
0.500 - 2.120
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.850
0.480 - 1.960
2.020
0.500 - 2.120
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.850
0.480 - 1.960
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.850
0.480 - 1.960
1.670
0.460 - 1.830
2.020
0.500 - 2.120
2.020
0.500 - 2.120
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.850
0.480 - 1.960
2.020
0.500 - 2.120
7.99
Power
factor
(%)
99
8.87
99
8.87
99
8.87
99
8.52
99
8.17
99
8.12
99
8.87
99
8.87
99
8.52
99
8.17
99
8.12
99
8.87
99
8.52
99
8.17
99
8.12
99
8.52
99
8.17
99
8.12
99
7.33
99
8.87
99
8.87
99
8.52
99
8.17
99
8.12
99
8.87
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
25+35+42
25+35+50
25+35+60
25+42+42
25+42+50
25+50+50
35+35+35
35+35+42
35+35+50
35+42+42
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+35+35
22+22+35+42
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+35+35
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
2.11
2.95
3.54
-
1.95
1.79
2.74
2.51
3.91
4.30
3.3
-
1.8
3.1
3.7
-
2.86
2.68
2.51
2.52
2.15
2.86
2.68
2.51
3.04
2.15
3.44
2.86
3.24
3.58
3.04
2.15
1.87
2.98
2.01
1.82
1.70
1.59
2.01
1.82
1.70
1.59
2.29
2.07
1.94
1.81
2.49
2.99
1.65
1.56
1.62
1.89
1.76
1.84
1.89
1.76
2.57
2.6
(
2.6
(
2.6
(
2.6
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
3.61
1.56
2.01
(
3.26
1.56
2.01
2.6
2.89
2.64
1.77
(
2.29
2.64
2.22
2.6
3.71
1.66
2.22
(
3.35
1.66
1.94
2.6
2.15
1.87
1.63
(
-
1.87
1.63
2.6
-
2.36
1.63
(
-
2.08
1.75
2.6
-
2.08
1.75
(
-
2.08
1.75
2.6
-
3.3
3.44
(
-
2.0
1.72
Total
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
(
3.4
2.22
2.81
3.17
3.52
2.57
27
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
-
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
Outdoor unit
power consumption
(kW)
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.850
0.480 - 1.960
1.940
0.490 - 2.040
1.860
0.480 - 1.960
1.670
0.460 - 1.830
2.020
0.500 - 2.120
1.940
0.500 - 2.040
1.860
0.500 - 1.960
1.940
0.490 - 2.040
1.950
0.600 - 1.960
1.950
0.600 - 1.960
1.950
0.600 - 1.960
1.860
0.600 - 1.940
1.770
0.600 - 1.930
1.950
0.600 - 1.960
1.950
0.600 - 1.960
1.860
0.600 - 1.940
1.770
0.600 - 1.930
1.950
0.600 - 1.960
1.860
0.600 - 1.940
1.950
0.600 - 1.960
1.950
0.600 - 1.960
1.860
0.600 - 1.940
1.770
0.600 - 1.930
1.950
0.600 - 1.960
8.52
Power
factor
(%)
99
8.17
99
8.12
99
8.52
99
8.17
99
7.33
99
8.87
99
8.52
99
8.17
99
8.52
99
8.56
99
8.56
99
8.56
99
8.17
99
7.77
99
8.56
99
8.56
99
8.17
99
7.77
99
8.56
99
8.17
99
8.56
99
8.56
99
8.17
99
7.77
99
8.56
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+25+35+42
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+35+35
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
1.53
1.73
2.43
2.91
2.15
2.15
2.15
2.15
8.6
8.6
8.6
8.6
8.6
8.6
-
1.95
1.95
1.95
1.83
1.83
3.11
1.72
1.72
1.72
3.44
1.79
2.51
3.4
(
3.4
(
3.4
2.75
1.83
1.79
(
(
3.4
(
3.4
(
3.4
2.51
28
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
9.0
) (
Outdoor unit
power consumption
(kW)
1.860
0.600 - 1.940
1.950
0.600 - 1.960
1.950
0.600 - 1.960
1.860
0.600 - 1.940
1.770
0.600 - 1.930
1.950
0.600 - 1.960
8.17
Power
factor
(%)
99
8.56
99
8.56
99
8.17
99
7.77
99
8.56
99
Current
(A)
)
)
)
)
)
)
MXZ-4A80VA
Indoor units
combination
22
25
35
42
50
60
71
22+22
22+25
22+35
22+42
22+50
22+60
22+71
25+25
25+35
25+42
25+50
25+60
25+71
35+35
35+42
35+50
35+60
35+71
42+42
NOTE: Electrical data is for outdoor unit only.
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
2.2
-
-
-
Total
(
2.5
-
-
-
3.5
-
-
-
(
(
4.2
-
-
(
5.0
-
-
(
6.0
-
-
(
7.1
-
-
(
2.2
2.2
-
(
2.2
2.5
-
(
2.2
3.5
-
-
2.2
4.2
-
-
(
(
2.2
5.0
-
(
1.75
6.00
-
(
1.66
6.19
-
(
2.5
2.5
-
(
2.5
3.5
-
(
2.5
4.2
-
(
2.5
5.0
-
-
2.11
5.64
-
-
(
(
2.01
5.84
-
(
3.5
3.5
-
(
3.5
4.2
-
(
3.10
4.65
-
(
2.61
5.24
-
(
2.51
5.44
-
(
3.95
3.95
-
(
2.2
- 3.0
2.5
1.4 - 3.3
3.5
1.5 - 4.3
4.2
1.6 - 5.0
5.0
1.6 - 5.6
6.0
1.6 - 6.6
7.1
1.7 - 7.4
4.4
2.0 - 5.4
4.7
2.0 - 5.8
5.7
2.0 - 6.6
6.4
2.0 - 7.2
7.2
2.0 - 7.7
7.75
2.0 - 8.0
7.9
2.0 - 8.2
5.0
2.0 - 6.2
6.0
2.0 - 7.1
6.7
2.0 - 7.8
7.5
2.0 - 8.5
7.75
2.0 - 8.6
7.85
2.0 - 8.7
7.0
2.0 - 7.1
7.7
2.0 - 8.0
7.75
2.0 - 8.8
7.85
2.0 - 8.8
7.95
2.0 - 8.8
7.9
2.0 - 8.2
1.4
29
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
0.680
0.400 - 0.920
0.760
0.400 - 1.010
1.030
0.400 - 1.290
1.230
0.410 - 1.460
1.440
0.420 - 1.630
1.930
0.400 - 2.130
2.580
0.410 - 2.710
1.130
0.600 - 1.600
1.270
0.600 - 1.770
1.710
0.600 - 2.200
2.080
0.580 - 2.450
2.450
0.560 - 2.710
2.750
0.560 - 3.050
2.810
0.560 - 3.200
1.360
0.580 - 1.950
2.010
0.580 - 2.540
2.290
0.570 - 2.870
2.580
0.560 - 3.200
2.750
0.560 - 3.280
2.810
0.560 - 3.320
2.400
0.580 - 2.550
2.580
0.570 - 2.880
2.760
0.560 - 3.220
2.730
0.560 - 3.180
2.780
0.560 - 3.180
2.860
0.570 - 2.890
2.99
Power
factor
(%)
99
3.34
99
4.52
99
5.40
99
6.32
99
8.48
99
11.33
99
4.96
99
5.58
99
7.51
99
9.13
99
10.76
99
12.08
99
12.34
99
5.97
99
8.83
99
10.06
99
11.33
99
12.08
99
12.34
99
10.54
99
11.33
99
12.12
99
11.99
99
12.21
99
12.56
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
42+50
42+60
42+71
50+50
50+60
50+71
60+60
60+71
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+22+71
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+25+71
22+35+35
22+35+42
22+35+50
22+35+60
22+35+71
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
3.6
4.3
-
-
3.3
4.7
-
-
7.9
2.0 - 8.8
8.0
2.0 - 8.8
8.0
2.0 - 8.8
7.9
2.1 - 8.8
8.0
2.1 - 8.8
8.0
2.1 - 8.8
8.0
2.1 - 8.8
8.0
2.1 - 8.8
6.6
2.9 - 8.1
6.9
2.9 - 8.3
7.7
2.9 - 8.3
7.85
2.9 - 8.7
7.85
2.9 - 9.0
7.95
2.9 - 9.0
8.0
2.9 - 9.0
7.2
2.9 - 8.9
7.75
2.9 - 8.9
7.9
2.9 - 9.0
7.9
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
7.85
2.9 - 9.0
7.9
2.9 - 9.0
7.9
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
(
(
3.0
5.0
-
(
3.95
3.95
-
-
3.43
4.57
-
-
(
(
3.27
4.73
-
(
4.00
4.00
-
(
3.84
4.16
-
(
2.2
2.2
2.2
-
2.2
2.2
2.5
-
(
(
2.14
2.14
3.42
(
2.01
2.01
3.83
-
1.72
1.72
4.41
-
(
(
1.46
1.46
5.03
(
1.4
1.4
5.2
(
2.2
2.5
2.5
(
2.08
2.36
3.31
-
1.95
2.22
3.73
-
(
(
1.79
2.04
4.07
(
1.64
1.87
4.49
-
1.49
1.69
4.82
-
(
(
1.87
2.99
2.99
(
1.76
2.79
3.35
(
1.63
2.58
3.69
(
1.5
2.4
4.1
-
1.38
2.18
4.44
-
(
(
30
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.860
0.560 - 3.190
2.880
0.560 - 3.150
2.880
0.560 - 3.150
2.780
0.590 - 3.160
2.800
0.570 - 3.120
2.800
0.570 - 3.120
2.690
0.550 - 3.080
2.690
0.550 - 3.080
1.860
0.690 - 2.410
1.970
0.670 - 2.510
2.310
0.690 - 2.970
2.310
0.690 - 2.940
2.320
0.700 - 2.920
2.370
0.680 - 2.880
2.390
0.680 - 2.880
2.100
0.690 - 2.940
2.350
0.690 - 2.970
2.360
0.690 - 2.940
2.370
0.700 - 2.920
2.390
0.680 - 2.880
2.390
0.680 - 2.880
2.350
0.690 - 2.920
2.330
0.690 - 2.900
2.320
0.700 - 2.890
2.350
0.680 - 2.860
2.350
0.680 - 2.860
12.56
Power
factor
(%)
99
12.65
99
12.65
99
12.21
99
12.30
99
12.30
99
11.81
99
11.81
99
8.17
99
8.65
99
10.14
99
10.14
99
10.19
99
10.41
99
10.50
99
9.22
99
10.32
99
10.36
99
10.41
99
10.50
99
10.50
99
10.32
99
10.23
99
10.19
99
10.32
99
10.32
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+42+42
22+42+50
22+42+60
22+42+71
22+50+50
22+50+60
22+50+71
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+25+71
25+35+35
25+35+42
25+35+50
25+35+60
25+35+71
25+42+42
25+42+50
25+42+60
25+42+71
25+50+50
25+50+60
35+35+35
35+35+42
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
1.65
3.15
3.15
-
1.53
2.93
3.49
-
7.95
2.9 - 9.0
7.95
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
7.5
2.9 - 9.0
7.75
2.9 - 9.0
7.9
2.9 - 9.0
7.9
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
7.85
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
8.0
2.9 - 9.0
7.95
2.9 - 9.0
8.0
2.9 - 9.0
(
(
1.4
2.7
3.9
(
1.3
2.5
4.2
-
1.44
3.28
3.28
-
(
(
1.33
3.03
3.64
(
1.23
2.80
3.97
(
2.5
2.5
2.5
(
2.28
2.28
3.19
-
2.14
2.14
3.62
-
(
(
1.98
1.98
3.94
(
1.82
1.82
4.36
-
1.65
1.65
4.70
-
(
(
2.07
2.89
2.89
(
1.96
2.75
3.29
(
1.82
2.54
3.64
(
1.67
2.33
4.00
-
1.53
2.14
4.33
-
(
(
1.8
3.1
3.1
(
1.7
2.9
3.4
-
1.6
2.6
3.8
-
(
(
1.45
2.43
4.12
(
1.6
3.2
3.2
(
1.48
2.96
3.56
(
2.65
2.65
2.65
-
2.5
2.5
3.0
-
(
(
31
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.300
0.680 - 2.880
2.290
0.690 - 2.870
2.320
0.670 - 2.840
2.320
0.670 - 2.840
2.330
0.680 - 2.860
2.300
0.660 - 2.830
2.300
0.660 - 2.830
2.250
0.690 - 3.010
2.350
0.690 - 2.970
2.360
0.690 - 2.940
2.370
0.700 - 2.920
2.390
0.680 - 2.880
2.390
0.680 - 2.880
2.350
0.690 - 2.920
2.360
0.690 - 2.900
2.380
0.700 - 2.890
2.350
0.680 - 2.860
2.350
0.680 - 2.860
2.330
0.670 - 2.870
2.350
0.680 - 2.860
2.320
0.670 - 2.840
2.320
0.670 - 2.840
2.330
0.660 - 2.840
2.300
0.660 - 2.830
2.280
0.720 - 2.910
2.270
0.710 - 2.890
10.10
Power
factor
(%)
99
10.06
99
10.19
99
10.19
99
10.23
99
10.10
99
10.10
99
9.88
99
10.32
99
10.36
99
10.41
99
10.50
99
10.50
99
10.32
99
10.36
99
10.45
99
10.32
99
10.32
99
10.23
99
10.32
99
10.19
99
10.19
99
10.23
99
10.10
99
10.01
99
9.97
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
35+35+50
35+35+60
35+35+71
35+42+42
35+42+50
35+42+60
35+50+50
35+50+60
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+22+60
22+22+22+71
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+25+60
22+22+25+71
22+22+35+35
22+22+35+42
22+22+35+50
22+22+35+60
22+22+42+42
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
2.33
2.33
3.34
-
2.15
2.15
3.70
-
1.99
1.99
4.02
-
2.4
2.8
2.8
-
2.20
2.65
3.15
-
2.0
2.08
1.93
2.5
2.96
2.76
3.5
2.96
3.31
-
1.95
1.95
1.95
1.95
1.90
1.90
1.90
2.15
1.73
1.73
1.73
2.76
1.63
1.63
1.63
3.11
1.52
1.52
1.52
3.44
1.4
1.28
1.87
1.4
1.28
1.87
1.4
1.28
2.13
3.8
4.16
2.13
1.68
1.68
1.91
1.91
1.58
1.58
1.80
3.04
1.48
1.48
1.68
3.36
1.36
1.36
1.55
3.73
1.26
1.26
1.43
4.05
1.54
1.45
1.36
1.54
1.45
1.36
2.46
2.31
2.18
2.46
2.79
3.10
1.12
1.12
1.92
3.84
1.4
1.4
2.6
2.6
Total
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
8.0
( 2.9 - 9.0
7.8
( 3.7 - 9.2
7.85
( 3.7 - 9.2
7.95
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
7.18
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
8.0
( 3.7 - 9.2
32
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.260
0.700 - 2.870
2.260
0.680 - 2.840
2.260
0.680 - 2.840
2.260
0.700 - 2.870
2.250
0.690 - 2.850
2.240
0.670 - 2.820
2.240
0.680 - 2.840
2.220
0.660 - 2.810
2.180
0.810 - 2.670
2.190
0.810 - 2.670
2.210
0.810 - 2.650
2.180
0.800 - 2.630
2.150
0.790 - 2.620
2.130
0.770 - 2.590
2.130
0.770 - 2.590
2.190
0.810 - 2.670
2.210
0.810 - 2.650
2.180
0.800 - 2.630
2.150
0.790 - 2.620
2.130
0.770 - 2.590
2.130
0.770 - 2.590
2.210
0.810 - 2.620
2.160
0.800 - 2.600
2.120
0.790 - 2.590
2.100
0.770 - 2.560
2.130
0.790 - 2.580
9.93
Power
factor
(%)
99
9.93
99
9.93
99
9.93
99
9.88
99
9.84
99
9.84
99
9.75
99
9.57
99
9.62
99
9.71
99
9.57
99
9.44
99
9.35
99
9.35
99
9.62
99
9.71
99
9.57
99
9.44
99
9.35
99
9.35
99
9.71
99
9.49
99
9.31
99
9.22
99
9.35
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+42+50
22+22+50+50
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+25+60
22+25+35+35
22+25+35+42
22+25+35+50
22+25+35+60
22+35+35+35
22+35+35+42
22+35+35+50
22+35+42+42
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+42
25+25+35+50
25+35+35+35
25+35+35+42
35+35+35+35
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Total
1.3
1.3
2.5
2.9
1.22
1.22
2.78
2.78
8.0
3.7 - 9.2
8.0
3.7 - 9.2
7.9
3.7 - 9.2
7.95
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
7.92
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
8.0
3.7 - 9.2
(
(
1.78
2.04
2.04
2.04
(
1.63
1.86
1.86
2.60
1.54
1.75
1.75
2.96
(
(
1.44
1.64
1.64
3.28
(
1.33
1.52
1.52
3.64
(
1.51
1.71
2.39
2.39
(
1.42
1.61
2.26
2.71
1.33
1.52
2.12
3.03
(
(
1.24
1.41
1.97
3.38
(
1.4
2.2
2.2
2.2
1.31
2.09
2.09
2.51
(
(
1.24
1.97
1.97
2.82
(
1.2
2.0
2.4
2.4
(
1.98
1.98
1.98
1.98
(
1.82
1.82
1.82
2.54
1.71
1.71
1.71
2.87
(
(
1.6
1.6
1.6
3.2
(
1.48
1.48
1.48
3.56
1.67
1.67
2.33
2.33
(
(
1.57
1.57
2.20
2.66
(
1.48
1.48
2.08
2.96
(
1.55
2.15
2.15
2.15
(
1.46
2.04
2.04
2.46
2.0
2.0
2.0
2.0
(
(
33
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.090
0.780 - 2.570
2.070
0.770 - 2.560
2.140
0.810 - 2.670
2.210
0.810 - 2.650
2.180
0.800 - 2.630
2.150
0.790 - 2.620
2.130
0.770 - 2.590
2.210
0.810 - 2.620
2.160
0.800 - 2.600
2.120
0.790 - 2.590
2.100
0.770 - 2.560
2.200
0.810 - 2.610
2.140
0.800 - 2.600
2.080
0.790 - 2.590
2.080
0.790 - 2.590
2.150
0.810 - 2.670
2.220
0.810 - 2.650
2.180
0.800 - 2.630
2.150
0.790 - 2.620
2.130
0.770 - 2.590
2.210
0.810 - 2.620
2.160
0.800 - 2.600
2.120
0.790 - 2.590
2.200
0.810 - 2.610
2.150
0.800 - 2.590
2.190
0.810 - 2.580
9.18
Power
factor
(%)
99
9.09
99
9.40
99
9.71
99
9.57
99
9.44
99
9.35
99
9.71
99
9.49
99
9.31
99
9.22
99
9.66
99
9.40
99
9.13
99
9.13
99
9.44
99
9.75
99
9.57
99
9.44
99
9.35
99
9.71
99
9.49
99
9.31
99
9.66
99
9.44
99
9.62
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22
25
35
42
50
60
71
22+22
22+25
22+35
22+42
22+50
22+60
22+71
25+25
25+35
25+42
25+50
25+60
25+71
35+35
35+42
35+50
35+60
35+71
42+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
3.3
-
-
-
3.6
-
-
-
Total
( 1.3
( 1.2
4.0
-
-
( 1.2
5.4
-
-
-
7.2
-
-
-
( 1.3
( 1.4
7.9
-
-
( 1.4
8.6
-
-
( 1.6
3.3
3.3
-
( 1.8
3.23
3.67
-
-
2.82
4.48
-
-
( 1.8
( 1.8
2.78
5.32
-
( 1.8
2.72
6.18
-
-
2.52
6.88
-
-
( 1.8
( 1.8
2.22
7.18
-
( 1.8
3.6
3.6
-
( 1.8
3.17
4.43
-
( 1.8
3.1
5.2
-
-
3.0
6.0
-
-
( 1.8
( 1.8
2.76
6.64
-
( 1.8
2.45
6.95
-
-
4.0
4.0
-
-
( 1.8
( 1.8
3.95
4.75
-
( 1.8
3.87
5.53
-
( 1.8
3.46
5.94
-
( 1.8
3.1
6.3
-
-
4.7
4.7
-
-
( 1.8
( 1.8
34
3.3
- 4.2
3.6
- 4.5
4.0
- 4.8
5.4
- 6.5
7.2
- 8.2
7.9
- 8.6
8.6
- 9.2
6.6
- 7.2
6.9
- 8.7
7.3
- 9.2
8.1
- 9.6
8.9
- 9.9
9.4
- 9.9
9.4
- 9.9
7.2
- 9.1
7.6
- 9.5
8.3
- 9.8
9.0
- 10.1
9.4
- 10.1
9.4
- 10.1
8.0
- 9.8
8.7
- 10.2
9.4
- 10.5
9.4
- 10.5
9.4
- 10.5
9.4
- 10.9
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
1.050
0.340 - 1.380
1.110
0.340 - 1.510
1.210
0.330 - 1.570
1.990
0.330 - 2.140
2.770
0.330 - 2.710
2.700
0.330 - 3.060
3.220
0.360 - 3.520
2.020
0.480 - 2.760
2.120
0.480 - 3.000
2.130
0.480 - 3.110
2.300
0.470 - 3.120
2.470
0.460 - 3.140
2.710
0.460 - 3.140
2.710
0.460 - 3.140
2.170
0.480 - 3.140
2.210
0.480 - 3.230
2.360
0.470 - 3.240
2.520
0.460 - 3.260
2.710
0.460 - 3.260
2.710
0.460 - 3.260
2.370
0.480 - 3.230
2.460
0.470 - 3.320
2.560
0.460 - 3.420
2.560
0.460 - 3.420
2.560
0.460 - 3.420
2.460
0.470 - 3.370
4.61
Power
factor
(%)
99
4.87
99
5.31
99
8.74
99
12.17
99
11.86
99
14.14
99
8.87
99
9.31
99
9.35
99
10.10
99
10.85
99
11.90
99
11.90
99
9.53
99
9.71
99
10.36
99
11.07
99
11.90
99
11.90
99
10.41
99
10.80
99
11.24
99
11.24
99
11.24
99
10.80
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
42+50
42+60
42+71
50+50
50+60
50+71
60+60
60+71
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+22+71
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+25+71
22+35+35
22+35+42
22+35+50
22+35+60
22+35+71
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
4.3
5.1
-
-
3.9
5.5
-
-
Total
( 1.8
( 1.8
3.5
5.9
-
( 1.8
4.7
4.7
-
-
4.3
5.1
-
-
( 1.9
( 1.9
3.88
5.52
-
( 1.9
4.7
4.7
-
( 1.9
4.31
5.09
-
( 1.9
2.9
2.9
2.9
-
2.81
2.81
3.18
-
( 2.6
( 2.6
2.62
2.62
4.16
( 2.6
2.4
2.4
4.6
-
2.2
2.2
5.0
-
( 2.6
( 2.6
1.99
1.99
5.42
( 2.6
1.8
1.8
5.8
( 2.6
2.72
3.09
3.09
( 2.6
2.52
2.87
4.01
-
2.32
2.64
4.44
-
( 2.6
( 2.6
2.13
2.42
4.85
( 2.6
1.93
2.20
5.27
-
1.75
1.99
5.66
-
( 2.6
( 2.6
2.24
3.58
3.58
( 2.6
2.09
3.32
3.99
( 2.7
1.93
3.07
4.39
( 2.7
1.77
2.81
4.82
-
1.62
2.57
5.21
-
( 2.7
( 2.7
35
9.4
- 10.9
9.4
- 10.9
9.4
- 10.9
9.4
- 11.2
9.4
- 11.2
9.4
- 11.2
9.4
- 11.2
9.4
- 11.2
8.7
- 10.6
8.8
- 11.1
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
8.9
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.460
0.460 - 3.370
2.460
0.460 - 3.370
2.460
0.460 - 3.370
2.370
0.440 - 3.320
2.370
0.440 - 3.320
2.370
0.440 - 3.320
2.370
0.440 - 3.320
2.370
0.440 - 3.320
2.150
0.530 - 3.060
2.170
0.530 - 3.300
2.310
0.530 - 3.400
2.210
0.520 - 3.360
2.120
0.510 - 3.330
2.120
0.510 - 3.330
2.120
0.510 - 3.330
2.170
0.530 - 3.420
2.270
0.530 - 3.410
2.180
0.520 - 3.370
2.100
0.510 - 3.330
2.100
0.510 - 3.330
2.100
0.510 - 3.330
2.210
0.530 - 3.400
2.130
0.520 - 3.310
2.050
0.510 - 3.230
2.050
0.510 - 3.230
2.050
0.510 - 3.230
10.80
Power
factor
(%)
99
10.80
99
10.80
99
10.41
99
10.41
99
10.41
99
10.41
99
10.41
99
9.44
99
9.53
99
10.14
99
9.71
99
9.31
99
9.31
99
9.31
99
9.53
99
9.97
99
9.57
99
9.22
99
9.22
99
9.22
99
9.71
99
9.35
99
9.00
99
9.00
99
9.00
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+42+42
22+42+50
22+42+60
22+42+71
22+50+50
22+50+60
22+50+71
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+25+71
25+35+35
25+35+42
25+35+50
25+35+60
25+35+71
25+42+42
25+42+50
25+42+60
25+42+71
25+50+50
25+50+60
35+35+35
35+35+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
2.0
3.7
3.7
-
1.8
3.5
4.1
-
Total
( 2.7
( 2.7
1.7
3.2
4.5
( 2.7
1.53
2.92
4.95
-
1.70
3.85
3.85
-
( 2.7
( 2.7
1.57
3.56
4.27
( 2.7
1.45
3.29
4.66
( 2.7
3.0
3.0
3.0
( 2.6
2.76
2.76
3.87
-
2.55
2.55
4.30
-
( 2.6
( 2.6
2.35
2.35
4.70
( 2.6
2.14
2.14
5.12
-
1.94
1.94
5.52
-
( 2.6
( 2.6
2.48
3.46
3.46
( 2.6
2.30
3.23
3.87
( 2.7
2.14
2.99
4.27
( 2.7
1.96
2.74
4.70
-
1.8
2.5
5.1
-
( 2.7
( 2.7
2.2
3.6
3.6
( 2.7
2.0
3.4
4.0
-
1.9
3.1
4.4
-
( 2.7
( 2.7
1.7
2.9
4.8
( 2.7
1.88
3.76
3.76
( 2.7
1.74
3.48
4.18
( 2.7
3.13
3.13
3.13
-
2.93
2.93
3.54
-
( 2.6
( 2.7
36
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.0
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.080
0.510 - 3.240
2.000
0.500 - 3.160
2.000
0.500 - 3.160
2.000
0.500 - 3.160
1.960
0.490 - 3.100
1.960
0.490 - 3.100
1.960
0.490 - 3.100
2.170
0.530 - 3.420
2.250
0.530 - 3.410
2.170
0.520 - 3.360
2.090
0.510 - 3.320
2.090
0.510 - 3.320
2.090
0.510 - 3.320
2.190
0.530 - 3.400
2.110
0.520 - 3.310
2.030
0.510 - 3.230
2.030
0.510 - 3.230
2.030
0.510 - 3.230
2.060
0.510 - 3.240
1.980
0.500 - 3.160
1.980
0.500 - 3.160
1.980
0.500 - 3.160
1.940
0.490 - 3.100
1.940
0.490 - 3.100
2.170
0.530 - 3.380
2.090
0.520 - 3.270
9.13
Power
factor
(%)
99
8.78
99
8.78
99
8.78
99
8.61
99
8.61
99
8.61
99
9.53
99
9.88
99
9.53
99
9.18
99
9.18
99
9.18
99
9.62
99
9.27
99
8.92
99
8.92
99
8.92
99
9.05
99
8.70
99
8.70
99
8.70
99
8.52
99
8.52
99
9.53
99
9.18
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
35+35+50
35+35+60
35+35+71
35+42+42
35+42+50
35+42+60
35+50+50
35+50+60
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+22+60
22+22+22+71
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+25+60
22+22+25+71
22+22+35+35
22+22+35+42
22+22+35+50
22+22+35+60
22+22+42+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
2.74
2.74
3.92
-
2.53
2.53
4.34
-
Total
( 2.7
( 2.7
2.33
2.33
4.74
( 2.7
2.8
3.3
3.3
-
2.6
3.1
3.7
-
( 2.7
( 2.7
2.4
2.9
4.1
( 2.7
2.44
3.48
3.48
( 2.7
2.27
3.24
3.89
( 2.7
2.35
2.35
2.35
2.35
2.27
2.27
2.27
2.59
( 3.4
( 3.4
2.05
2.05
2.05
3.25
( 3.4
1.91
1.91
1.91
3.67
1.78
1.78
1.78
4.06
( 3.5
( 3.5
1.64
1.64
1.64
4.48
( 3.5
1.51
1.51
1.51
4.87
( 3.5
2.2
2.2
2.5
2.5
( 3.5
1.99
1.99
2.26
3.16
1.86
1.86
2.12
3.56
( 3.4
( 3.5
1.74
1.74
1.97
3.95
( 3.5
1.60
1.60
1.83
4.37
1.48
1.48
1.68
4.76
( 3.5
( 3.5
1.81
1.81
2.89
2.89
( 3.4
1.71
1.71
2.72
3.26
( 3.5
1.60
1.60
2.55
3.65
( 3.5
1.49
1.49
2.37
4.05
1.6
1.6
3.1
3.1
( 3.5
( 3.4
37
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.010
0.510 - 3.160
2.010
0.510 - 3.160
2.010
0.510 - 3.160
2.040
0.510 - 3.200
1.960
0.500 - 3.090
1.960
0.500 - 3.090
1.920
0.490 - 3.030
1.920
0.490 - 3.030
2.020
0.590 - 3.420
1.990
0.590 - 3.410
1.960
0.590 - 3.390
1.930
0.580 - 3.320
1.910
0.580 - 3.260
1.910
0.580 - 3.260
1.910
0.580 - 3.260
1.980
0.590 - 3.400
1.940
0.590 - 3.390
1.910
0.580 - 3.330
1.890
0.580 - 3.270
1.890
0.580 - 3.270
1.890
0.580 - 3.270
1.910
0.590 - 3.340
1.860
0.580 - 3.280
1.820
0.580 - 3.220
1.820
0.580 - 3.220
1.820
0.560 - 3.230
8.83
Power
factor
(%)
99
8.83
99
8.83
99
8.96
99
8.61
99
8.61
99
8.43
99
8.43
99
8.87
99
8.74
99
8.61
99
8.48
99
8.39
99
8.39
99
8.39
99
8.70
99
8.52
99
8.39
99
8.30
99
8.30
99
8.30
99
8.39
99
8.17
99
7.99
99
7.99
99
7.99
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+42+50
22+22+50+50
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+25+60
22+25+35+35
22+25+35+42
22+25+35+50
22+25+35+50
22+35+35+35
22+35+35+42
22+35+35+50
22+35+42+42
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+42
25+25+35+50
25+35+35+35
25+35+35+42
35+35+35+35
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
1.5
1.5
2.9
3.5
1.44
1.44
3.26
3.26
Total
( 3.4
( 3.4
2.14
2.42
2.42
2.42
( 3.4
1.93
2.20
2.20
3.07
1.81
2.06
2.06
3.47
( 3.4
( 3.5
1.70
1.93
1.93
3.84
( 3.5
1.57
1.78
1.78
4.27
( 3.5
1.77
2.01
2.81
2.81
( 3.4
1.67
1.90
2.65
3.18
1.57
1.78
2.49
3.56
( 3.5
( 3.5
1.46
1.65
2.32
3.97
( 3.5
1.63
2.59
2.59
2.59
1.53
2.46
2.46
2.95
( 3.4
( 3.5
1.45
2.32
2.32
3.31
( 3.5
1.5
2.3
2.8
2.8
( 3.4
2.35
2.35
2.35
2.35
( 3.4
2.14
2.14
2.14
2.98
2.01
2.01
2.01
3.37
( 3.4
( 3.5
1.88
1.88
1.88
3.76
( 3.5
1.74
1.74
1.74
4.18
1.96
1.96
2.74
2.74
( 3.5
( 3.4
1.85
1.85
2.59
3.11
( 3.5
1.74
1.74
2.44
3.48
( 3.5
1.81
2.53
2.53
2.53
( 3.4
1.72
2.40
2.40
2.88
2.35
2.35
2.35
2.35
( 3.5
( 3.4
38
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
9.4
- 11.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
1.780
0.560 - 3.170
1.750
0.550 - 3.130
1.960
0.590 - 3.390
1.920
0.590 - 3.370
1.890
0.580 - 3.300
1.870
0.580 - 3.230
1.870
0.580 - 3.230
1.890
0.590 - 3.320
1.840
0.580 - 3.260
1.800
0.580 - 3.200
1.800
0.580 - 3.200
1.860
0.590 - 3.280
1.820
0.580 - 3.240
1.780
0.580 - 3.210
1.780
0.560 - 3.200
1.950
0.590 - 3.390
1.910
0.590 - 3.350
1.880
0.580 - 3.280
1.860
0.580 - 3.210
1.860
0.580 - 3.210
1.870
0.590 - 3.300
1.820
0.580 - 3.240
1.780
0.580 - 3.190
1.840
0.590 - 3.260
1.790
0.580 - 3.200
1.930
0.590 - 3.230
7.82
Power
factor
(%)
99
7.69
99
8.61
99
8.43
99
8.30
99
8.21
99
8.21
99
8.30
99
8.08
99
7.91
99
7.91
99
8.17
99
7.99
99
7.82
99
7.82
99
8.56
99
8.39
99
8.26
99
8.17
99
8.17
99
8.21
99
7.99
99
7.82
99
8.08
99
7.86
99
8.48
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
MXZ-5A100VA
Indoor units
combination
22
25
35
42
50
60
71
22+22
22+25
22+35
22+42
22+50
22+60
22+71
25+25
25+35
25+42
25+50
25+60
25+71
35+35
35+42
35+50
35+60
35+71
42+42
NOTE: Electrical data is for outdoor unit only.
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
2.20
-
-
-
-
Total
(
2.50
-
-
-
-
3.50
-
-
-
-
4.20
5.00
6.00
7.10
2.20
2.20
2.20
2.50
-
-
4.20
-
-
-
1.87
2.50
2.50
2.50
6.03
2.50
3.50
4.20
-
-
5.51
-
-
-
3.36
3.21
2.91
2.74
3.90
4.04
4.59
4.99
5.56
3.90
-
-
1.7
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
-
2.29
3.50
(
-
-
3.50
0.6
-
-
-
(
-
-
-
1.6
-
5.00
5.84
(
-
2.50
2.06
1.6
-
2.20
5.71
(
-
-
2.09
1.5
-
-
-
(
-
-
-
1.4
-
3.50
5.00
(
-
2.20
2.20
1.4
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
(
2.0
39
2.2
2.5
3.5
4.2
5.0
6.0
7.1
4.4
4.7
5.7
6.4
7.2
7.8
7.9
5.0
6.0
6.7
7.5
7.8
7.9
7.0
7.4
7.8
7.9
8.3
7.8
-
3.0
) (
3.3
) (
4.3
) (
5.0
) (
5.6
) (
6.6
) (
7.4
) (
5.4
) (
5.8
) (
6.6
) (
7.2
) (
7.7
) (
8.0
) (
8.2
) (
6.2
) (
7.1
) (
7.8
) (
8.5
) (
8.6
) (
8.7
) (
7.1
) (
8.0
) (
8.8
) (
8.8
) (
8.8
) (
8.8
) (
Outdoor unit
power consumption
(kW)
0.680
0.400 - 0.920
0.760
0.400 - 1.010
1.030
0.400 - 1.290
1.230
0.410 - 1.460
1.440
0.420 - 1.630
1.930
0.400 - 2.130
2.580
0.410 - 2.710
1.130
0.600 - 1.600
1.270
0.600 - 1.770
1.710
0.600 - 2.200
2.080
0.580 - 2.450
2.450
0.560 - 2.710
2.750
0.560 - 3.050
2.810
0.560 - 3.200
1.360
0.580 - 1.950
2.010
0.540 - 2.540
2.290
0.550 - 2.870
2.580
0.560 - 3.200
2.750
0.560 - 3.280
2.810
0.560 - 3.320
2.400
0.540 - 2.550
2.580
0.550 - 2.910
2.760
0.560 - 3.280
2.730
0.560 - 3.280
3.050
0.560 - 3.280
2.760
0.560 - 3.280
2.99
Power
factor
(%)
99
3.34
99
4.52
99
5.40
99
6.32
99
8.48
99
11.33
99
4.96
99
5.58
99
7.51
99
9.13
99
10.76
99
12.08
99
12.34
99
5.97
99
8.83
99
10.06
99
11.33
99
12.08
99
12.34
99
10.54
99
11.33
99
12.12
99
11.99
99
13.39
99
12.12
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
42+50
42+60
42+71
50+50
50+60
50+71
60+60
60+71
71+71
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+22+71
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+25+71
22+35+35
22+35+42
22+35+50
22+35+60
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
3.61
4.29
-
-
-
3.34
4.76
-
-
-
7.9
8.1
8.6
8.3
8.6
8.9
8.9
9.1
9.1
6.6
6.9
7.7
7.8
7.9
8.6
8.6
7.2
7.8
8.2
8.5
8.6
8.7
7.9
8.2
8.5
8.7
-
3.20
5.40
-
-
4.15
-
-
-
3.91
4.69
-
-
-
4.45
4.17
5.22
4.45
4.93
-
-
-
2.20
2.20
2.20
-
-
-
2.14
3.42
-
-
1.99
1.99
3.82
-
-
1.82
1.65
1.85
1.82
1.65
4.20
4.96
5.30
-
-
2.09
2.38
3.33
-
-
-
2.19
4.38
-
-
1.77
2.01
4.82
-
-
1.88
1.82
1.84
3.01
2.90
5.24
3.01
3.48
-
2.1
(
2.1
(
2.1
(
2.1
(
2.1
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
-
1.93
1.62
(
-
2.50
3.87
2.1
-
2.50
2.30
(
-
2.20
2.03
2.1
-
2.14
1.85
(
-
-
2.50
2.0
-
4.55
2.20
(
-
4.55
2.20
2.0
-
4.15
3.68
(
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
-
1.75
2.78
3.97
-
-
1.64
2.60
4.46
-
-
(
2.9
(
2.9
40
8.8
) (
8.8
) (
9.1
) (
9.1
) (
9.2
) (
9.3
) (
9.3
) (
9.4
) (
9.5
) (
8.1
) (
8.3
) (
9.0
) (
9.0
) (
9.0
) (
9.4
) (
9.4
) (
8.9
) (
9.0
) (
9.2
) (
9.4
) (
9.4
) (
9.4
) (
9.0
) (
9.2
) (
9.4
) (
9.4
) (
Outdoor unit
power consumption
(kW)
2.740
0.560 - 3.280
2.890
0.560 - 3.280
3.170
0.550 - 3.440
3.050
0.590 - 3.480
3.250
0.570 - 3.600
3.300
0.550 - 3.600
3.300
0.550 - 3.600
3.450
0.550 - 3.700
3.400
0.550 - 3.700
1.860
0.690 - 2.410
1.970
0.670 - 2.510
2.310
0.690 - 2.970
2.310
0.690 - 2.940
2.320
0.700 - 2.920
2.650
0.680 - 3.000
2.680
0.680 - 3.000
2.100
0.690 - 2.940
2.350
0.690 - 2.970
2.500
0.690 - 3.000
2.650
0.700 - 3.040
2.680
0.680 - 3.000
2.680
0.680 - 3.000
2.350
0.690 - 2.920
2.470
0.690 - 2.960
2.600
0.700 - 3.010
2.630
0.680 - 2.970
12.03
Power
factor
(%)
99
12.69
99
13.92
99
13.39
99
14.27
99
14.49
99
14.49
99
15.15
99
14.93
99
8.17
99
8.65
99
10.14
99
10.14
99
10.19
99
11.64
99
11.77
99
9.22
99
10.32
99
10.98
99
11.64
99
11.77
99
11.77
99
10.32
99
10.85
99
11.42
99
11.55
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+35+71
22+42+42
22+42+50
22+42+60
22+42+71
22+50+50
22+50+60
22+50+71
22+60+60
22+60+71
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+25+71
25+35+35
25+35+42
25+35+50
25+35+60
25+35+71
25+42+42
25+42+50
25+42+60
25+42+71
25+50+50
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
1.58
2.52
5.10
-
-
1.70
3.25
3.25
-
-
9.2
8.2
8.6
9.0
9.2
9.0
9.2
9.2
9.2
9.3
7.5
7.8
8.2
8.5
8.6
9.0
7.9
8.3
8.6
9.0
9.2
8.6
8.8
9.1
9.2
9.2
-
1.66
3.17
3.77
-
3.05
4.35
-
-
1.50
2.86
4.84
-
-
1.53
1.41
3.69
3.48
3.22
3.69
4.19
4.57
-
-
1.33
3.65
4.32
-
-
-
2.29
3.22
-
-
2.23
2.23
3.74
-
-
1.95
1.86
2.13
1.95
1.86
4.24
4.70
5.28
-
-
2.03
2.85
3.42
-
-
-
2.63
4.50
-
-
1.75
2.46
4.99
-
-
1.88
1.79
3.31
3.16
3.01
3.31
3.76
4.30
-
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
-
1.87
1.98
(
-
2.91
3.91
2.9
-
2.91
2.74
(
-
2.08
1.95
2.9
-
2.29
2.13
(
-
3.89
2.50
2.9
-
3.89
2.50
(
-
1.42
2.50
2.9
-
1.60
1.62
(
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
-
1.67
2.80
4.73
-
-
1.84
3.68
3.68
-
-
(
2.9
(
2.9
41
9.8
) (
9.4
) (
9.4
) (
9.6
) (
9.9
) (
9.8
) (
9.9
) (
10.0
) (
10.0
) (
10.5
) (
9.0
) (
9.0
) (
9.2
) (
9.4
) (
9.4
) (
9.8
) (
9.0
) (
9.2
) (
9.4
) (
9.8
) (
9.9
) (
9.4
) (
9.6
) (
9.9
) (
10.0
) (
9.9
) (
Outdoor unit
power consumption
(kW)
2.810
0.680 - 3.120
2.600
0.700 - 3.010
2.610
0.690 - 2.990
2.720
0.680 - 3.040
2.890
0.670 - 3.140
2.690
0.680 - 3.170
2.800
0.660 - 3.140
2.970
0.660 - 3.170
2.970
0.660 - 3.170
3.000
0.600 - 3.340
2.250
0.690 - 3.010
2.350
0.690 - 2.970
2.500
0.690 - 3.000
2.650
0.700 - 3.040
2.680
0.680 - 3.000
2.680
0.680 - 3.170
2.350
0.690 - 2.920
2.510
0.690 - 2.960
2.670
0.700 - 3.010
2.690
0.680 - 3.120
2.820
0.680 - 3.140
2.670
0.700 - 3.010
2.680
0.690 - 3.060
2.750
0.680 - 3.130
2.770
0.670 - 3.150
2.820
0.660 - 3.140
12.34
Power
factor
(%)
99
11.42
99
11.46
99
11.95
99
12.69
99
11.81
99
12.30
99
13.04
99
13.04
99
13.18
99
9.88
99
10.32
99
10.98
99
11.64
99
11.77
99
11.77
99
10.32
99
11.02
99
11.73
99
11.81
99
12.38
99
11.73
99
11.77
99
12.08
99
12.17
99
12.38
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
25+50+60
25+50+71
25+60+60
25+60+71
35+35+35
35+35+42
35+35+50
35+35+60
35+35+71
35+42+42
35+42+50
35+42+60
35+42+71
35+50+50
35+50+60
35+50+71
35+60+60
35+60+71
42+42+42
42+42+50
42+42+60
42+42+71
42+50+50
42+50+60
42+50+71
42+60+60
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
1.70
3.41
4.09
-
-
1.58
3.15
4.47
-
-
9.2
9.2
9.2
9.4
8.6
8.8
9.0
9.2
9.1
9.0
9.1
9.2
9.3
9.0
9.2
9.4
9.4
9.5
9.0
9.2
9.3
9.4
9.3
9.4
9.5
9.5
-
1.58
3.81
3.81
-
3.62
4.27
-
-
2.87
2.87
2.87
-
-
2.63
2.48
2.70
2.63
2.48
3.40
3.74
4.24
-
-
2.64
3.18
3.18
-
-
-
2.82
4.03
-
-
2.20
2.64
4.46
-
-
2.22
2.11
3.33
3.17
3.01
3.33
3.81
4.28
-
-
2.00
3.43
4.07
-
-
-
2.88
3.44
-
-
2.71
2.71
3.88
-
-
2.76
2.60
2.54
3.27
3.09
4.32
3.27
3.71
-
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
-
2.88
2.54
(
-
3.64
3.00
2.9
-
3.64
3.00
(
-
2.12
3.00
2.9
-
2.35
2.34
(
-
4.58
3.58
2.9
-
2.26
3.01
(
-
2.26
2.51
2.9
-
1.51
2.70
(
(
2.9
(
2.9
(
2.9
(
2.9
(
2.9
-
2.45
2.91
4.14
-
-
2.46
3.52
3.52
-
-
(
2.9
(
2.9
42
9.9
) (
10.0
) (
10.0
) (
10.5
) (
9.4
) (
9.6
) (
9.8
) (
9.9
) (
10.0
) (
9.8
) (
9.9
) (
10.0
) (
10.3
) (
9.9
) (
10.0
) (
10.5
) (
10.5
) (
10.8
) (
9.9
) (
10.0
) (
10.2
) (
10.5
) (
10.2
) (
10.5
) (
10.8
) (
10.8
) (
Outdoor unit
power consumption
(kW)
2.800
0.660 - 3.140
2.730
0.660 - 3.170
2.730
0.660 - 3.170
2.800
0.660 - 3.330
2.550
0.720 - 3.030
2.620
0.710 - 3.070
2.690
0.700 - 3.120
2.810
0.680 - 3.140
2.740
0.680 - 3.170
2.690
0.700 - 3.120
2.750
0.690 - 3.130
2.770
0.680 - 3.150
2.760
0.670 - 3.250
2.720
0.680 - 3.140
2.730
0.660 - 3.170
2.790
0.660 - 3.330
2.790
0.660 - 3.330
2.780
0.660 - 3.430
2.750
0.690 - 3.130
2.760
0.680 - 3.140
2.760
0.670 - 3.200
2.790
0.660 - 3.330
2.760
0.670 - 3.200
2.760
0.660 - 3.310
2.810
0.660 - 3.400
2.810
0.660 - 3.400
12.30
Power
factor
(%)
99
11.99
99
11.99
99
12.30
99
11.20
99
11.51
99
11.81
99
12.34
99
12.03
99
11.81
99
12.08
99
12.17
99
12.12
99
11.95
99
11.99
99
12.25
99
12.25
99
12.21
99
12.08
99
12.12
99
12.12
99
12.25
99
12.12
99
12.12
99
12.34
99
12.34
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
50+50+50
50+50+60
50+50+71
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+22+60
22+22+22+71
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+25+60
22+22+25+71
22+22+35+35
22+22+35+42
22+22+35+50
22+22+35+60
22+22+35+71
22+22+42+42
22+22+42+50
22+22+42+60
22+22+42+71
22+22+50+50
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
3.13
3.13
3.13
-
-
2.97
2.97
3.56
-
-
9.4
9.5
9.6
7.8
7.9
8.1
8.4
8.6
9.0
9.2
8.0
8.6
8.8
8.9
9.0
9.0
8.6
8.9
9.0
9.0
9.4
9.0
9.0
9.2
9.5
9.7
-
2.81
2.81
3.98
-
1.95
1.95
1.95
-
1.91
1.91
1.91
2.17
-
1.71
1.63
1.76
1.71
1.63
1.76
1.71
1.63
2.82
3.27
3.71
4.29
-
1.48
1.48
1.48
4.76
-
2.13
1.82
2.07
2.89
-
1.74
1.74
1.98
3.34
-
1.53
1.41
1.65
1.53
1.41
1.87
1.74
1.61
3.73
4.20
4.57
2.64
-
1.62
1.62
2.57
3.09
-
3.50
1.42
2.27
3.89
-
1.38
1.38
2.19
4.45
-
1.45
1.38
1.55
1.45
1.38
2.95
2.78
2.65
2.95
3.32
3.79
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
1.42
1.55
(
-
2.64
2.44
3.7
-
1.66
1.53
(
-
1.66
1.53
2.9
-
1.82
1.65
(
-
1.57
2.13
2.9
-
1.57
1.87
(
-
1.57
1.87
2.9
-
1.95
1.76
(
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
1.33
1.33
2.54
4.30
-
1.48
1.48
3.37
3.37
-
(
3.7
(
3.7
43
10.8
) (
10.9
) (
11.0
) (
9.2
) (
9.2
) (
9.4
) (
9.7
) (
9.9
) (
10.1
) (
10.1
) (
9.4
) (
9.9
) (
10.1
) (
10.2
) (
10.1
) (
10.0
) (
9.9
) (
10.1
) (
10.1
) (
10.0
) (
10.5
) (
10.1
) (
10.1
) (
10.3
) (
10.5
) (
10.9
) (
Outdoor unit
power consumption
(kW)
2.790
0.660 - 3.430
2.790
0.660 - 3.450
2.830
0.660 - 3.480
2.180
0.810 - 2.670
2.190
0.810 - 2.670
2.280
0.810 - 2.730
2.340
0.800 - 2.830
2.410
0.790 - 2.930
2.510
0.770 - 3.000
2.570
0.770 - 2.980
2.260
0.810 - 2.750
2.480
0.810 - 2.970
2.470
0.800 - 2.990
2.460
0.790 - 3.020
2.510
0.770 - 2.950
2.490
0.770 - 2.920
2.480
0.810 - 2.930
2.490
0.800 - 2.940
2.510
0.790 - 2.950
2.490
0.770 - 2.920
2.580
0.770 - 3.060
2.510
0.790 - 2.950
2.500
0.780 - 2.930
2.530
0.770 - 2.990
2.560
0.770 - 3.040
2.740
0.770 - 3.250
12.25
Power
factor
(%)
99
12.25
99
12.43
99
9.57
99
9.62
99
10.01
99
10.28
99
10.58
99
11.02
99
11.29
99
9.93
99
10.89
99
10.85
99
10.80
99
11.02
99
10.94
99
10.89
99
10.94
99
11.02
99
10.94
99
11.33
99
11.02
99
10.98
99
11.11
99
11.24
99
12.03
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+50+60
22+22+50+71
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+25+60
22+25+25+71
22+25+35+35
22+25+35+42
22+25+35+50
22+25+35+60
22+25+35+71
22+25+42+42
22+25+42+50
22+25+42+60
22+25+42+71
22+25+50+50
22+25+50+60
22+25+50+71
22+35+35+35
22+35+35+42
22+35+35+50
22+35+35+60
22+35+35+71
22+35+42+42
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
1.34
1.34
3.05
3.67
-
1.28
1.28
2.91
4.13
-
9.4
9.6
8.1
8.6
8.7
8.8
9.0
9.4
8.9
9.0
9.0
9.4
9.4
9.0
9.2
9.4
9.5
9.4
9.4
9.6
9.2
9.3
9.4
9.4
9.6
9.4
-
1.83
2.09
2.09
2.09
2.01
2.01
2.81
-
1.67
1.91
1.91
3.21
-
1.50
1.45
1.80
1.70
1.64
1.80
1.70
1.64
3.61
4.10
4.67
2.66
-
1.60
1.81
2.54
3.05
-
3.41
1.65
2.32
3.97
-
1.35
1.54
2.15
4.36
-
1.46
1.39
1.71
1.65
1.57
2.89
2.78
2.65
2.89
3.31
3.79
4.22
-
1.40
1.60
3.20
3.20
-
3.59
1.43
2.86
4.06
-
1.58
2.54
2.54
2.54
-
1.45
1.36
2.43
2.32
2.16
2.43
2.32
2.16
2.91
3.31
3.72
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
1.25
1.53
(
-
2.49
2.99
3.7
-
1.48
1.50
(
-
1.31
1.32
3.7
-
1.46
1.51
(
-
2.66
2.39
3.7
-
1.90
1.70
(
-
1.67
1.50
3.7
-
1.77
1.59
(
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
1.30
2.06
2.06
4.18
-
1.47
2.33
2.80
2.80
-
(
3.7
(
3.7
44
10.5
) (
10.5
) (
9.4
) (
9.9
) (
10.1
) (
10.1
) (
10.2
) (
10.5
) (
10.2
) (
10.2
) (
10.2
) (
10.5
) (
10.6
) (
10.2
) (
10.4
) (
10.6
) (
10.8
) (
10.5
) (
11.0
) (
11.0
) (
10.3
) (
10.2
) (
10.0
) (
10.5
) (
10.9
) (
10.0
) (
Outdoor unit
power consumption
(kW)
2.580
0.770 - 3.060
2.550
0.770 - 3.030
2.200
0.810 - 2.750
2.480
0.810 - 2.970
2.450
0.800 - 2.960
2.430
0.790 - 2.950
2.510
0.770 - 3.000
2.580
0.770 - 3.060
2.460
0.810 - 3.020
2.480
0.810 - 3.010
2.510
0.810 - 3.000
2.600
0.770 - 3.060
2.580
0.770 - 3.100
2.510
0.810 - 3.000
2.550
0.790 - 3.030
2.590
0.770 - 3.080
2.550
0.770 - 3.130
2.600
0.770 - 3.060
2.580
0.770 - 3.210
2.530
0.770 - 3.170
2.580
0.810 - 3.040
2.590
0.800 - 2.980
2.600
0.790 - 2.920
2.580
0.770 - 3.060
2.560
0.770 - 3.170
2.600
0.790 - 2.920
11.33
Power
factor
(%)
99
11.20
99
9.66
99
10.89
99
10.76
99
10.67
99
11.02
99
11.33
99
10.80
99
10.89
99
11.02
99
11.42
99
11.33
99
11.02
99
11.20
99
11.37
99
11.20
99
11.42
99
11.33
99
11.11
99
11.33
99
11.37
99
11.42
99
11.33
99
11.24
99
11.42
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+35+42+50
22+35+42+60
22+35+42+71
22+35+50+50
22+35+50+60
22+42+42+42
22+42+42+50
22+42+42+60
22+42+50+50
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+25+60
25+25+25+71
25+25+35+35
25+25+35+42
25+25+35+50
25+25+35+60
25+25+35+71
25+25+42+42
25+25+42+50
25+25+42+60
25+25+42+71
25+25+50+50
25+25+50+60
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
1.39
2.21
2.65
3.15
-
1.32
2.09
2.51
3.58
-
9.4
9.5
9.6
9.6
9.6
9.4
9.5
9.6
9.6
8.6
8.6
8.9
9.0
9.1
9.4
8.8
9.1
9.2
9.4
9.6
9.2
9.3
9.5
9.6
9.4
9.6
-
1.24
1.98
2.37
4.01
2.14
3.06
3.06
-
1.26
2.01
2.87
3.44
-
1.34
1.27
2.67
2.56
2.43
2.67
2.56
2.43
2.67
3.04
3.47
2.93
-
2.15
2.15
2.15
2.15
-
2.75
1.90
1.90
3.20
-
1.80
1.80
1.80
3.60
-
1.61
1.83
1.69
1.61
1.83
1.69
1.61
2.57
4.03
4.57
2.57
3.01
-
1.70
1.70
2.39
3.41
-
3.89
1.54
2.15
4.37
-
1.72
1.72
2.88
2.88
-
1.56
1.47
1.64
1.56
1.47
2.75
2.63
2.46
3.27
3.75
4.20
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
1.54
1.64
(
-
2.51
2.27
3.7
-
1.79
1.62
(
-
1.79
1.62
3.7
-
1.90
1.69
(
-
2.93
1.95
3.7
-
2.45
1.95
(
-
1.29
1.95
3.7
-
1.34
1.39
(
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
1.57
1.57
3.13
3.13
-
1.50
1.50
3.00
3.60
-
(
3.7
(
3.7
45
10.3
) (
10.7
) (
11.0
) (
10.9
) (
11.0
) (
10.3
) (
10.7
) (
11.0
) (
11.0
) (
9.9
) (
9.9
) (
10.1
) (
10.1
) (
10.2
) (
10.5
) (
10.1
) (
10.2
) (
10.2
) (
10.5
) (
11.0
) (
10.2
) (
10.4
) (
10.8
) (
11.0
) (
10.5
) (
11.0
) (
Outdoor unit
power consumption
(kW)
2.600
0.800 - 3.000
2.600
0.800 - 3.200
2.530
0.770 - 3.170
2.540
0.770 - 3.170
2.530
0.770 - 3.170
2.600
0.800 - 3.000
2.600
0.800 - 3.200
2.530
0.770 - 3.170
2.530
0.770 - 3.170
2.410
0.810 - 2.990
2.490
0.810 - 2.970
2.500
0.800 - 2.960
2.510
0.790 - 2.950
2.530
0.770 - 3.000
2.580
0.770 - 3.060
2.430
0.810 - 2.950
2.530
0.800 - 2.970
2.640
0.790 - 3.000
2.600
0.770 - 3.060
2.650
0.770 - 3.210
2.640
0.790 - 3.000
2.600
0.800 - 3.100
2.700
0.800 - 3.200
2.560
0.770 - 3.170
2.550
0.770 - 3.060
2.560
0.770 - 3.170
11.42
Power
factor
(%)
99
11.42
99
11.11
99
11.16
99
11.11
99
11.42
99
11.42
99
11.11
99
11.11
99
10.58
99
10.94
99
10.98
99
11.02
99
11.11
99
11.33
99
10.67
99
11.11
99
11.59
99
11.42
99
11.64
99
11.59
99
11.42
99
11.86
99
11.24
99
11.20
99
11.24
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
25+25+50+71
25+35+35+35
25+35+35+42
25+35+35+50
25+35+35+60
25+35+35+71
25+35+42+42
25+35+42+50
25+35+42+60
25+42+42+42
25+42+42+50
25+42+42+60
25+42+50+50
35+35+35+35
35+35+35+42
35+35+35+50
35+35+35+60
35+35+42+42
35+35+42+50
35+42+42+42
35+42+42+50
42+42+42+42
22+22+22+22+22
22+22+22+22+25
22+22+22+22+35
22+22+22+22+42
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.43
1.43
2.87
4.07
-
1.74
2.42
2.42
2.42
-
1.68
2.35
2.35
2.82
2.27
2.27
3.24
-
1.55
2.17
2.17
3.71
-
1.63
1.56
2.02
2.29
2.19
2.02
2.74
2.62
4.11
2.74
3.13
3.56
-
1.58
2.64
2.64
2.64
-
3.02
2.43
2.43
3.48
-
1.48
2.46
2.93
2.93
-
2.26
2.17
2.35
2.26
2.17
2.35
2.26
2.17
2.35
2.72
3.09
3.48
-
2.16
2.16
2.64
2.64
-
2.97
2.50
2.50
2.50
-
2.03
2.43
2.43
2.91
-
2.00
1.95
2.45
2.00
1.95
2.45
2.00
1.95
2.45
2.00
1.95
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
(
3.7
-
2.10
2.45
3.7
-
2.04
2.49
(
-
2.04
2.07
3.7
-
2.04
2.07
(
-
1.46
2.35
3.7
-
2.49
2.54
(
-
2.07
2.54
3.7
-
1.48
1.50
(
-
1.62
1.45
Total
(
3.7
(
3.7
(
3.7
(
3.9
(
3.9
2.00
2.20
1.79
1.79
1.79
1.79
2.84
1.69
1.69
1.69
1.69
3.24
(
3.9
(
3.9
46
9.8
- 11.0
9.0
- 10.2
9.2
- 10.4
9.4
10.5
9.6
10.5
9.6
10.9
9.4
- 10.5
9.5
- 10.5
9.6
- 10.7
9.5
- 10.5
9.6
- 10.7
9.8
- 11.0
9.8
- 11.0
9.4
- 10.5
9.5
- 10.8
9.6
- 11.0
9.6
- 10.9
9.6
- 11.0
9.6
- 11.0
9.6
- 11.0
9.8
- 11.0
9.8
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.610
0.770 - 3.170
2.510
0.810 - 2.840
2.540
0.800 - 2.950
2.580
0.790
3.060
2.650
0.790
3.060
2.560
0.770
3.170
2.580
0.790 - 3.060
2.700
0.800 - 3.100
2.700
0.800 - 3.200
2.700
0.800 - 3.100
2.700
0.800 - 3.200
2.610
0.770 - 3.170
2.610
0.770 - 3.170
2.570
0.810 - 3.100
2.600
0.790 - 3.150
2.640
0.770 - 3.210
2.560
0.770 - 3.170
2.640
0.770 - 3.210
2.600
0.800 - 3.200
2.600
0.800 - 3.200
2.610
0.770 - 3.170
2.610
0.770 - 3.170
2.935
0.780 - 3.500
2.935
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
11.46
Power
factor
(%)
99
11.02
99
11.16
99
11.33
99
11.64
99
11.24
99
11.33
99
11.86
99
11.86
99
11.86
99
11.86
99
11.46
99
11.46
99
11.29
99
11.42
99
11.59
99
11.24
99
11.59
99
11.42
99
11.42
99
11.46
99
11.46
99
12.89
99
12.89
99
12.89
99
12.82
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+22+22+50
22+22+22+22+60
22+22+22+22+71
22+22+22+25+25
22+22+22+25+35
22+22+22+25+42
22+22+22+25+50
22+22+22+25+60
22+22+22+25+71
22+22+22+35+35
22+22+22+35+42
22+22+22+35+50
22+22+22+35+60
22+22+22+35+71
22+22+22+42+42
22+22+22+42+50
22+22+22+42+60
22+22+25+25+25
22+22+25+25+35
22+22+25+25+42
22+22+25+25+50
22+22+25+25+60
22+22+25+25+71
22+22+25+35+35
22+22+25+35+42
22+22+25+35+50
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.59
1.59
1.59
1.59
3.64
1.49
1.49
1.49
1.49
4.04
1.38
1.38
1.38
1.38
1.90
1.90
2.15
2.15
1.75
1.75
1.75
1.97
2.78
1.56
1.46
1.65
1.56
1.46
1.65
1.56
1.46
1.88
1.77
1.66
1.54
4.38
1.62
1.62
1.62
2.57
2.57
2.45
1.46
1.46
2.32
3.30
1.37
1.37
1.37
2.17
3.72
1.46
1.39
1.28
1.46
1.39
1.28
1.46
1.39
2.03
2.81
2.66
2.50
3.57
1.85
1.85
2.10
2.10
2.10
1.94
1.61
1.84
1.84
3.10
1.53
1.53
1.74
1.74
3.46
1.33
1.58
1.43
1.33
1.58
1.62
1.52
1.80
1.62
1.52
2.52
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
2.70
1.61
1.43
3.9
3.17
1.31
1.94
(
2.81
1.31
1.71
3.9
4.13
1.31
1.71
(
2.96
1.46
1.28
3.9
3.96
1.36
1.53
(
3.55
1.36
1.53
3.9
3.17
1.36
1.53
(
4.48
1.90
1.65
Total
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
3.90
4.30
2.52
1.50
1.50
1.71
2.40
2.89
1.43
1.43
1.62
2.27
3.25
(
3.9
(
3.9
47
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.915
0.790 - 3.490
2.905
0.800 - 3.480
2.905
0.800 - 3.480
2.935
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.800 - 3.480
2.905
0.800 - 3.480
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.800 - 3.480
2.905
0.780 - 3.500
2.915
0.790 - 3.490
2.900
0.800 - 3.500
2.900
0.800 - 3.500
2.935
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.800 - 3.480
2.905
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
12.80
Power
factor
(%)
99
12.76
99
12.76
99
12.89
99
12.89
99
12.82
99
12.80
99
12.76
99
12.76
99
12.89
99
12.82
99
12.80
99
12.76
99
12.76
99
12.80
99
12.74
99
12.74
99
12.89
99
12.89
99
12.82
99
12.80
99
12.76
99
12.76
99
12.89
99
12.82
99
12.80
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+25+35+60
22+22+25+42+42
22+22+25+42+50
22+22+25+42+60
22+22+35+35+35
22+22+35+35+42
22+22+35+35+50
22+22+35+42+42
22+22+35+42+50
22+22+42+42+42
22+25+25+25+25
22+25+25+25+35
22+25+25+25+42
22+25+25+25+50
22+25+25+25+60
22+25+25+25+71
22+25+25+35+35
22+25+25+35+42
22+25+25+35+50
22+25+25+35+60
22+25+25+42+42
22+25+25+42+50
22+25+35+35+35
22+25+35+35+42
22+25+35+35+50
22+25+35+42+42
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.34
1.34
1.53
2.13
3.66
1.43
1.43
1.64
2.75
2.75
1.36
1.36
1.55
2.60
1.28
1.46
2.45
3.53
1.47
1.48
2.35
2.35
2.35
1.34
1.35
1.41
1.34
1.35
2.24
2.13
2.14
2.24
2.13
2.58
2.47
2.92
1.28
1.28
2.48
2.48
2.48
2.05
1.89
1.89
1.89
2.66
1.58
1.80
1.80
1.80
3.02
1.40
1.30
1.70
1.59
1.49
1.70
1.59
1.49
1.70
1.59
1.49
2.46
2.46
1.47
1.68
1.68
2.35
2.82
2.23
1.50
1.50
2.10
3.59
1.42
1.60
1.60
2.69
2.69
1.46
1.39
1.52
1.64
1.57
1.52
2.30
2.20
2.56
2.30
2.20
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
3.19
1.31
1.35
3.9
4.23
1.76
1.59
(
3.83
1.76
1.59
3.9
3.40
1.56
1.40
(
2.05
1.67
1.50
3.9
2.58
2.05
2.05
(
3.06
1.28
2.05
3.9
2.70
1.28
1.80
(
3.13
1.28
1.41
Total
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
3.05
2.30
2.64
1.32
1.49
2.10
2.10
2.99
1.32
1.51
2.11
2.53
2.53
(
3.9
(
3.9
48
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.905
0.780 - 3.500
2.915
0.790 - 3.490
2.900
0.800 - 3.500
2.900
0.800 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.500
2.905
0.780 - 3.500
2.900
0.800 - 3.500
2.900
0.800 - 3.500
2.900
0.800 - 3.500
2.935
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.800 - 3.480
2.905
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.780 - 3.500
2.915
0.790 - 3.490
2.905
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.500
2.905
0.780 - 3.500
2.905
0.780 - 3.500
12.76
Power
factor
(%)
99
12.80
99
12.74
99
12.74
99
12.89
99
12.82
99
12.76
99
12.74
99
12.74
99
12.74
99
12.89
99
12.89
99
12.82
99
12.80
99
12.76
99
12.76
99
12.89
99
12.82
99
12.80
99
12.76
99
12.80
99
12.76
99
12.89
99
12.82
99
12.76
99
12.76
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+35+35+35+35
22+35+35+35+42
25+25+25+25+25
25+25+25+25+35
25+25+25+25+42
25+25+25+25+50
25+25+25+25+60
25+25+25+25+71
25+25+25+35+35
25+25+25+35+42
25+25+25+35+50
25+25+25+35+60
25+25+25+42+42
25+25+25+42+50
25+25+35+35+35
25+25+35+35+42
25+25+35+35+50
25+25+35+42+42
Cooling capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.36
2.16
2.16
2.16
2.16
1.30
2.07
2.07
2.07
2.49
2.00
2.00
2.00
2.00
1.85
1.85
1.85
2.60
1.76
1.76
1.76
1.76
2.96
1.56
1.46
1.67
1.56
1.46
1.67
1.56
1.46
1.67
1.56
1.46
2.42
2.42
1.64
1.64
1.64
2.30
2.78
2.19
1.47
1.47
2.06
3.53
1.56
1.56
1.56
2.66
2.66
1.61
1.54
1.50
1.61
1.54
1.50
2.26
2.16
2.52
2.26
2.16
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
3.13
1.47
1.49
3.9
4.16
1.72
1.56
(
3.76
1.72
1.56
3.9
3.32
1.72
1.56
(
2.00
1.85
1.67
Total
(
3.9
(
3.9
(
3.9
(
3.9
(
3.9
2.99
2.26
2.60
1.47
1.47
2.06
2.06
2.94
1.48
1.48
2.07
2.48
2.49
(
3.9
(
3.9
49
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
10.0
- 11.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.920
0.780 - 3.500
2.905
0.780 - 3.500
2.935
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.780 - 3.500
2.905
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.500
2.905
0.780 - 3.500
2.905
0.780 - 3.500
2.905
0.780 - 3.500
2.905
0.780 - 3.500
2.935
0.780 - 3.500
2.920
0.780 - 3.490
2.915
0.790 - 3.490
2.905
0.780 - 3.500
12.82
Power
factor
(%)
99
12.76
99
12.89
99
12.89
99
12.82
99
12.80
99
12.76
99
12.76
99
12.89
99
12.82
99
12.76
99
12.76
99
12.76
99
12.76
99
12.89
99
12.82
99
12.80
99
12.76
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22
25
35
42
50
60
71
22+22
22+25
22+35
22+42
22+50
22+60
22+71
25+25
25+35
25+42
25+50
25+60
25+71
35+35
35+42
35+50
35+60
35+71
42+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Total
3.30
-
-
-
-
3.60
-
-
-
-
3.3
3.6
4.0
5.4
7.2
7.9
8.6
6.6
6.9
7.3
8.1
4.00
-
-
-
-
-
-
-
7.20
-
-
-
-
8.60
3.30
3.30
-
-
-
2.82
4.48
-
-
-
-
6.18
-
-
-
2.68
7.32
-
-
-
3.60
3.17
7.63
3.60
4.43
-
-
-
3.00
6.00
-
-
-
-
7.77
-
-
-
4.00
4.00
-
-
-
4.32
3.87
5.07
6.18
6.63
-
-
1.4
(
1.4
(
1.6
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
-
2.73
4.23
(
-
-
-
1.3
-
5.20
7.41
(
-
3.10
3.09
1.2
-
2.72
2.37
(
-
-
-
1.2
-
3.67
5.32
(
-
3.23
2.78
1.2
-
5.40
7.90
(
(
1.8
(
1.8
(
1.8
(
1.8
(
1.8
-
3.50
7.10
-
-
-
5.25
5.25
-
-
-
(
1.8
(
1.8
50
4.6
) (
5.0
) (
5.3
) (
6.8
) (
8.2
) (
8.6
) (
9.2
) (
7.2
) (
8.7
) (
9.2
) (
9.9
) (
8.9
- 10.5
10.0
- 10.5
10.0
- 10.5
7.2
9.1
7.6
9.5
8.3
9.8
9.0
- 10.1
10.5
- 11.2
10.5
- 11.3
8.0
9.8
9.3
- 10.5
10.5
- 11.0
10.5
- 11.1
10.6
- 11.4
10.5
- 11.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
1.050
0.340 - 1.590
1.110
0.340 - 1.740
1.210
0.330 - 1.810
1.740
0.330 - 2.260
2.270
0.330 - 2.710
2.700
0.330 - 3.060
3.220
0.360 - 3.520
2.020
0.480 - 2.760
2.120
0.480 - 3.000
2.130
0.480 - 3.110
2.300
0.470 - 3.230
2.470
0.460 - 3.360
2.900
0.460 - 3.360
2.900
0.460 - 3.360
2.170
0.480 - 3.140
2.210
0.480 - 3.230
2.360
0.470 - 3.240
2.520
0.460 - 3.260
3.390
0.460 - 3.660
3.390
0.460 - 3.690
2.370
0.480 - 3.230
2.770
0.470 - 3.400
3.180
0.460 - 3.580
3.180
0.460 - 3.610
3.210
0.460 - 3.690
3.180
0.460 - 3.580
4.61
Power
factor
(%)
99
4.87
99
5.31
99
7.64
99
9.97
99
11.86
99
14.14
99
8.87
99
9.31
99
9.35
99
10.10
99
10.85
99
12.74
99
12.74
99
9.53
99
9.71
99
10.36
99
11.07
99
14.89
99
14.89
99
10.41
99
12.17
99
13.97
99
13.97
99
14.10
99
13.97
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
42+50
42+60
42+71
50+50
50+60
50+71
60+60
60+71
71+71
22+22+22
22+22+25
22+22+35
22+22+42
22+22+50
22+22+60
22+22+71
22+25+25
22+25+35
22+25+42
22+25+50
22+25+60
22+25+71
22+35+35
22+35+42
22+35+50
22+35+60
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
4.79
5.71
-
-
-
4.36
6.24
-
-
-
3.94
6.66
-
-
5.30
-
-
-
4.82
5.78
-
-
-
5.30
4.85
6.22
5.30
5.75
-
-
-
2.90
2.90
2.90
-
-
-
2.78
4.44
-
-
2.68
2.68
5.14
-
-
2.33
2.10
2.57
2.33
2.10
5.86
6.35
6.80
-
-
2.68
3.05
4.27
-
-
-
2.84
5.67
-
-
2.26
2.57
6.17
-
-
2.52
2.40
2.33
3.99
3.82
6.62
3.99
4.58
-
(
1.9
(
1.9
(
1.9
(
1.9
(
1.9
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
-
2.49
2.05
1.9
-
3.09
4.96
(
-
3.09
2.95
1.9
-
2.72
2.59
(
-
2.78
2.57
1.8
-
-
3.19
(
-
5.30
2.81
1.8
-
5.30
2.80
(
-
5.30
4.38
Total
(
2.6
(
2.6
(
2.6
(
2.6
(
2.7
-
2.26
3.60
5.14
-
-
2.07
3.29
5.64
-
-
(
2.7
(
2.7
51
10.5
- 11.1
10.6
- 11.3
10.6
- 11.7
10.6
- 11.9
10.6
- 11.9
10.6
- 12.0
10.6
- 12.0
10.6
- 12.1
10.6
- 12.2
8.7
- 10.6
8.8
- 11.1
10.0
- 12.6
10.5
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
8.9
- 12.6
10.0
- 12.6
10.5
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
10.5
- 12.6
10.8
- 12.6
11.0
- 12.6
11.0
- 12.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
3.180
0.460 - 3.590
3.190
0.460 - 3.650
3.090
0.450 - 3.780
2.980
0.440 - 3.770
2.980
0.440 - 3.770
2.980
0.440 - 3.870
2.980
0.440 - 3.870
2.980
0.440 - 3.910
2.980
0.440 - 3.960
2.150
0.530 - 3.060
2.170
0.530 - 3.330
2.810
0.530 - 3.710
2.850
0.520 - 3.530
2.900
0.510 - 3.350
2.890
0.510 - 3.340
2.890
0.510 - 3.340
2.170
0.530 - 3.420
2.750
0.530 - 3.700
2.810
0.520 - 3.520
2.880
0.510 - 3.340
2.870
0.510 - 3.330
2.870
0.510 - 3.330
2.970
0.530 - 3.700
2.920
0.520 - 3.510
2.870
0.510 - 3.330
2.860
0.510 - 3.320
13.97
Power
factor
(%)
99
14.01
99
13.57
99
13.09
99
13.09
99
13.09
99
13.09
99
13.09
99
13.09
99
9.44
99
9.53
99
12.34
99
12.52
99
12.74
99
12.69
99
12.69
99
9.53
99
12.08
99
12.34
99
12.65
99
12.60
99
12.60
99
13.04
99
12.82
99
12.60
99
12.56
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+35+71
22+42+42
22+42+50
22+42+60
22+42+71
22+50+50
22+50+60
22+50+71
22+60+60
22+60+71
25+25+25
25+25+35
25+25+42
25+25+50
25+25+60
25+25+71
25+35+35
25+35+42
25+35+50
25+35+60
25+35+71
25+42+42
25+42+50
25+42+60
25+42+71
25+50+50
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.89
3.01
6.10
-
-
2.28
4.36
4.36
-
-
2.12
4.06
4.82
-
3.73
5.32
-
-
1.79
3.42
5.79
-
-
1.83
1.69
4.51
4.17
3.85
4.51
5.00
5.46
-
-
1.58
4.31
5.11
-
-
-
2.97
4.16
-
-
2.88
2.88
4.84
-
-
2.50
2.27
2.75
2.50
2.27
5.50
6.00
6.46
-
-
2.65
3.70
4.45
-
-
-
3.21
5.50
-
-
2.10
2.94
5.96
-
-
2.35
2.16
4.24
3.95
3.64
4.24
4.70
5.20
-
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.6
(
2.7
(
2.7
-
2.29
2.52
2.7
-
3.87
5.00
(
-
3.87
3.50
2.7
-
2.76
2.50
(
-
2.97
2.75
2.7
-
4.65
3.00
(
-
4.65
3.00
2.7
-
1.70
3.00
(
-
1.95
1.98
Total
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
-
1.99
3.35
5.66
-
-
2.20
4.40
4.40
-
-
(
2.7
(
2.7
52
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
9.0
- 12.6
10.1
- 12.6
10.6
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
10.5
- 12.6
10.8
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.860
0.510 - 3.320
2.870
0.510 - 3.330
2.860
0.510 - 3.320
2.860
0.510 - 3.320
2.780
0.500 - 3.350
2.720
0.490 - 3.270
2.710
0.490 - 3.390
2.710
0.490 - 3.380
2.710
0.490 - 3.380
2.710
0.490 - 3.380
2.170
0.530 - 3.750
2.480
0.530 - 3.750
2.670
0.520 - 3.600
2.870
0.510 - 3.450
2.860
0.510 - 3.440
2.860
0.510 - 3.440
2.890
0.530 - 3.700
2.720
0.520 - 3.570
2.550
0.510 - 3.440
2.860
0.510 - 3.430
2.850
0.510 - 3.260
2.550
0.510 - 3.440
2.700
0.510 - 3.430
2.850
0.510 - 3.340
2.770
0.500 - 3.250
2.700
0.490 - 3.260
12.56
Power
factor
(%)
99
12.60
99
12.56
99
12.56
99
12.21
99
11.95
99
11.90
99
11.90
99
11.90
99
11.90
99
9.53
99
10.89
99
11.73
99
12.60
99
12.56
99
12.56
99
12.69
99
11.95
99
11.20
99
12.56
99
12.52
99
11.20
99
11.86
99
12.52
99
12.17
99
11.86
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
25+50+60
25+50+71
25+60+60
25+60+71
35+35+35
35+35+42
35+35+50
35+35+60
35+35+71
35+42+42
35+42+50
35+42+60
35+42+71
35+50+50
35+50+60
35+50+71
35+60+60
35+60+71
42+42+42
42+42+50
42+42+60
42+42+71
42+50+50
42+50+60
42+50+71
42+60+60
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
2.04
4.07
4.89
-
-
1.88
3.77
5.35
-
-
1.90
4.55
4.55
-
4.23
5.01
-
-
3.33
3.33
3.33
-
-
3.21
2.96
3.28
3.21
2.96
3.94
4.58
5.08
-
-
3.24
3.88
3.88
-
-
-
3.37
4.82
-
-
2.60
3.12
5.28
-
-
2.66
2.46
4.07
3.79
3.53
4.07
4.55
5.01
-
-
2.32
3.98
4.70
-
-
-
3.45
4.10
-
-
3.21
3.21
4.58
-
-
3.26
3.04
2.98
3.87
3.62
5.04
3.87
4.34
-
(
2.6
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
-
3.45
2.98
2.7
-
4.26
3.60
(
-
4.26
3.60
2.7
-
2.48
3.60
(
-
2.81
2.86
2.7
-
5.54
4.33
(
-
2.73
3.64
2.7
-
2.73
3.03
(
-
1.76
3.28
Total
(
2.7
(
2.7
(
2.7
(
2.7
(
2.7
-
2.83
3.38
4.79
-
-
2.86
4.07
4.07
-
-
(
2.7
(
2.7
53
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
10.0
- 12.6
10.5
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
10.8
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.700
0.490 - 3.380
2.700
0.490 - 3.250
2.700
0.490 - 3.250
2.700
0.490 - 3.250
2.730
0.530 - 3.700
2.790
0.520 - 3.560
2.850
0.510 - 3.430
2.850
0.510 - 3.430
2.850
0.510 - 3.430
2.850
0.510 - 3.430
2.850
0.510 - 3.430
2.850
0.510 - 3.430
2.770
0.500 - 3.340
2.700
0.490 - 3.250
2.700
0.490 - 3.250
2.700
0.490 - 3.250
2.700
0.490 - 3.250
2.700
0.490 - 3.250
2.850
0.510 - 3.430
2.850
0.510 - 3.430
2.810
0.500 - 3.380
2.700
0.490 - 3.250
2.810
0.500 - 3.380
2.690
0.490 - 3.240
2.690
0.490 - 3.240
2.690
0.490 - 3.240
11.86
Power
factor
(%)
99
11.86
99
11.86
99
11.86
99
11.99
99
12.25
99
12.52
99
12.52
99
12.52
99
12.52
99
12.52
99
12.52
99
12.17
99
11.86
99
11.86
99
11.86
99
11.86
99
11.86
99
12.52
99
12.52
99
12.34
99
11.86
99
12.34
99
11.81
99
11.81
99
11.81
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
50+50+50
50+50+60
50+50+71
22+22+22+22
22+22+22+25
22+22+22+35
22+22+22+42
22+22+22+50
22+22+22+60
22+22+22+71
22+22+25+25
22+22+25+35
22+22+25+42
22+22+25+50
22+22+25+60
22+22+25+71
22+22+35+35
22+22+35+42
22+22+35+50
22+22+35+60
22+22+35+71
22+22+42+42
22+22+42+50
22+22+42+60
22+22+42+71
22+22+50+50
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
3.67
3.67
3.67
-
-
3.43
3.44
4.13
-
-
3.22
3.22
4.56
-
2.50
2.50
2.50
-
2.42
2.42
2.42
2.74
-
2.20
2.09
2.29
2.20
2.09
2.29
2.20
2.09
3.64
4.20
4.73
5.24
-
1.77
1.77
1.77
5.69
-
2.66
2.22
2.52
3.54
-
2.14
2.14
2.43
4.09
-
1.88
1.73
2.03
1.88
1.73
2.31
2.13
1.96
4.63
5.11
5.58
3.22
-
1.96
1.96
3.12
3.76
-
4.26
1.74
2.77
4.75
-
1.61
1.61
2.57
5.21
-
1.78
1.66
1.89
1.78
1.66
3.61
3.40
3.16
3.61
4.04
4.52
(
3.4
(
3.4
(
3.5
(
3.5
(
3.5
(
3.5
(
3.4
(
3.4
(
3.5
(
3.5
(
3.5
(
3.5
(
3.4
(
3.5
(
3.5
-
1.74
1.89
3.4
-
3.22
2.98
(
-
2.03
1.88
2.7
-
2.03
1.88
(
-
2.22
2.03
2.7
-
1.92
2.66
(
-
1.92
2.34
2.7
-
1.92
2.34
(
-
2.50
2.29
Total
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
-
1.54
1.54
2.94
4.98
-
1.68
1.68
3.82
3.82
-
(
3.5
(
3.4
54
11.0
- 12.6
11.0
- 12.6
11.0
- 12.6
10.0
- 13.3
10.0
- 13.3
10.5
- 13.3
10.8
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
10.0
- 13.3
10.5
- 13.3
10.8
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
10.5
- 13.3
10.8
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.700
0.490 - 3.250
2.690
0.490 - 3.240
2.690
0.490 - 3.240
2.180
0.590 - 3.900
2.170
0.590 - 3.900
2.290
0.590 - 3.900
2.340
0.580 - 3.890
2.390
0.580 - 3.890
2.380
0.580 - 3.880
2.380
0.580 - 3.880
2.160
0.590 - 3.900
2.280
0.590 - 3.900
2.330
0.580 - 3.890
2.380
0.580 - 3.890
2.370
0.580 - 3.880
2.370
0.580 - 3.880
2.280
0.590 - 3.900
2.320
0.580 - 3.890
2.370
0.580 - 3.890
2.360
0.580 - 3.880
2.360
0.580 - 3.880
2.370
0.580 - 3.890
2.360
0.580 - 3.880
2.360
0.580 - 3.880
2.310
0.580 - 3.890
2.270
0.550 - 3.880
11.86
Power
factor
(%)
99
11.81
99
11.81
99
9.57
99
9.53
99
10.06
99
10.28
99
10.50
99
10.45
99
10.45
99
9.49
99
10.01
99
10.23
99
10.45
99
10.41
99
10.41
99
10.01
99
10.19
99
10.41
99
10.36
99
10.36
99
10.41
99
10.36
99
10.36
99
10.14
99
9.97
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+50+60
22+22+50+71
22+25+25+25
22+25+25+35
22+25+25+42
22+25+25+50
22+25+25+60
22+25+25+71
22+25+35+35
22+25+35+42
22+25+35+50
22+25+35+60
22+25+35+71
22+25+42+42
22+25+42+50
22+25+42+60
22+25+42+71
22+25+50+50
22+25+50+60
22+25+50+71
22+35+35+35
22+35+35+42
22+35+35+50
22+35+35+60
22+35+35+71
22+35+42+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.57
1.57
3.57
4.29
-
1.47
1.47
3.33
4.73
-
2.37
2.71
2.71
2.71
2.45
2.45
3.44
-
2.08
2.37
2.37
3.98
-
1.83
1.69
2.25
2.08
1.92
2.25
2.08
1.92
4.52
5.01
5.47
3.29
-
1.95
2.22
3.10
3.73
-
4.17
1.94
2.71
4.65
-
1.58
1.80
2.52
5.10
-
1.74
1.62
2.10
1.98
1.85
3.53
3.32
3.10
3.53
3.96
4.43
4.88
-
1.65
1.87
3.74
3.74
-
4.21
1.64
3.27
4.65
-
1.91
3.03
3.03
3.03
-
1.70
1.59
2.87
2.71
2.53
2.87
2.71
2.53
3.45
3.88
4.35
(
3.5
(
3.5
(
3.5
(
3.5
(
3.4
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
-
1.44
1.81
3.4
-
2.89
3.50
(
-
1.72
1.75
3.4
-
1.51
1.54
(
-
1.70
1.84
3.5
-
3.29
2.92
(
-
2.35
2.08
3.5
-
2.07
1.83
(
-
2.16
1.98
Total
(
3.5
(
3.4
(
3.5
(
3.5
(
3.5
-
1.48
2.36
2.36
4.80
-
1.71
2.73
3.28
3.28
-
(
3.5
(
3.5
55
11.0
- 13.3
11.0
- 13.3
10.5
- 13.3
10.5
- 13.3
10.8
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.260
0.580 - 3.870
2.260
0.580 - 3.900
2.290
0.590 - 3.900
2.280
0.590 - 3.900
2.330
0.580 - 3.890
2.380
0.580 - 3.890
2.360
0.580 - 3.880
2.360
0.580 - 3.880
2.520
0.590 - 3.900
2.430
0.580 - 3.890
2.350
0.580 - 3.890
2.340
0.580 - 3.880
2.340
0.580 - 3.880
2.350
0.580 - 3.890
2.340
0.580 - 3.880
2.340
0.580 - 3.880
2.290
0.580 - 3.890
2.260
0.580 - 3.880
2.250
0.580 - 3.870
2.250
0.580 - 3.900
2.550
0.590 - 3.900
2.450
0.580 - 3.890
2.350
0.580 - 3.890
2.340
0.580 - 3.880
2.340
0.580 - 3.900
2.350
0.580 - 3.890
9.93
Power
factor
(%)
99
9.93
99
10.06
99
10.01
99
10.23
99
10.45
99
10.36
99
10.36
99
11.07
99
10.67
99
10.32
99
10.28
99
10.28
99
10.32
99
10.28
99
10.28
99
10.06
99
9.93
99
9.88
99
9.88
99
11.20
99
10.76
99
10.32
99
10.28
99
10.28
99
10.32
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+35+42+50
22+35+42+60
22+35+42+71
22+35+50+50
22+35+50+60
22+42+42+42
22+42+42+50
22+42+42+60
22+42+50+50
25+25+25+25
25+25+25+35
25+25+25+42
25+25+25+50
25+25+25+60
25+25+25+71
25+25+35+35
25+25+35+42
25+25+35+50
25+25+35+60
25+25+35+71
25+25+42+42
25+25+42+50
25+25+42+60
25+25+42+71
25+25+50+50
25+25+50+60
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.61
2.59
3.10
3.69
-
1.52
2.42
2.91
4.15
-
1.42
2.27
2.72
4.59
2.45
3.50
3.51
-
1.45
2.31
3.29
3.95
-
1.55
1.46
3.12
2.96
2.79
3.12
2.96
2.79
3.12
3.53
3.96
3.35
-
2.50
2.50
2.50
2.50
-
3.19
2.24
2.24
3.78
-
2.20
2.20
2.20
4.40
-
1.88
2.29
2.04
1.88
2.29
2.04
1.88
3.21
4.88
5.36
3.21
3.65
-
2.04
2.04
2.85
4.07
-
4.54
1.76
2.47
5.01
-
2.05
2.05
3.45
3.45
-
1.81
1.68
1.93
1.81
1.68
3.25
3.04
2.83
3.88
4.34
4.80
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.4
(
3.4
(
3.5
(
3.5
(
3.5
(
3.5
(
3.4
(
3.5
(
3.5
(
3.5
-
1.76
1.93
3.5
-
3.03
2.66
(
-
2.16
1.90
3.5
-
2.16
1.90
(
-
2.24
2.04
3.5
-
3.35
2.27
(
-
2.82
2.27
3.5
-
1.48
2.27
(
-
1.54
7.88
Total
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
-
1.83
1.83
3.67
3.67
-
1.72
1.72
3.44
4.12
-
(
3.5
(
3.5
56
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
17.2
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
10.0
- 13.3
10.0
- 13.3
10.5
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.400
0.600 - 3.900
2.300
0.600 - 3.900
2.250
0.580 - 3.900
2.240
0.580 - 3.880
2.250
0.580 - 3.900
2.400
0.600 - 3.900
2.300
0.600 - 3.900
2.250
0.580 - 3.900
2.250
0.580 - 3.900
2.160
0.590 - 3.900
2.150
0.590 - 3.900
2.250
0.580 - 3.890
2.360
0.580 - 3.890
2.350
0.580 - 3.880
2.350
0.580 - 3.880
2.550
0.590 - 3.900
2.440
0.580 - 3.890
2.330
0.580 - 3.890
2.300
0.580 - 3.880
2.300
0.580 - 3.880
2.330
0.580 - 3.890
2.300
0.600 - 3.900
2.300
0.600 - 3.900
2.240
0.580 - 3.880
2.250
0.580 - 3.880
2.240
0.580 - 3.880
10.54
Power
factor
(%)
99
10.10
99
9.88
99
9.84
99
9.88
99
10.54
99
10.10
99
9.88
99
9.88
99
9.49
99
9.44
99
9.88
99
10.36
99
10.32
99
10.32
99
11.20
99
10.72
99
10.23
99
10.10
99
10.10
99
10.23
99
10.10
99
10.10
99
9.84
99
9.88
99
9.84
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
25+25+50+71
25+35+35+35
25+35+35+42
25+35+35+50
25+35+35+60
25+35+35+71
25+35+42+42
25+35+42+50
25+35+42+60
25+42+42+42
25+42+42+50
25+42+42+60
25+42+50+50
35+35+35+35
35+35+35+42
35+35+35+50
35+35+35+60
35+35+42+42
35+35+42+50
35+42+42+42
35+42+42+50
42+42+42+42
22+22+22+22+22
22+22+22+22+25
22+22+22+22+35
22+22+22+22+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.61
1.61
3.22
4.56
-
2.12
2.96
2.96
2.96
-
2.01
2.81
2.81
3.37
2.66
2.66
3.79
-
1.77
2.48
2.48
4.27
-
1.91
1.81
2.32
2.67
2.53
2.32
3.21
3.04
4.70
3.21
3.62
4.07
-
1.82
3.06
3.06
3.06
-
3.46
2.73
2.73
3.91
-
1.65
2.77
3.29
3.29
-
2.62
2.48
2.75
2.62
2.48
2.75
2.62
2.48
2.75
3.14
3.56
4.01
-
2.50
2.50
3.00
3.00
-
3.41
2.87
2.87
2.87
-
2.27
2.74
2.74
3.25
-
2.40
2.34
2.75
2.40
2.34
2.75
2.40
2.34
2.75
2.40
2.34
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
(
3.4
(
3.5
(
3.5
(
3.5
(
3.5
(
3.5
-
2.39
2.75
3.5
-
2.33
2.85
(
-
2.33
2.37
3.5
-
2.33
2.37
(
-
1.63
2.75
3.4
-
2.85
2.91
(
-
2.38
2.91
3.5
-
1.70
1.72
(
-
1.89
1.66
Total
(
3.5
(
3.5
(
3.5
(
4.1
(
4.1
2.40
2.64
2.15
2.15
2.15
2.15
3.40
2.03
2.03
2.03
2.03
3.88
(
4.1
(
4.1
57
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
13.3
11.0
13.3
11.0
13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
11.0
- 13.3
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.240
0.580 - 3.880
2.520
0.590 - 3.900
2.400
0.580 - 3.890
2.290
0.580
3.890
2.290
0.580
3.880
2.290
0.580
3.900
2.290
0.580 - 3.890
2.300
0.600 - 3.900
2.300
0.600 - 3.900
2.300
0.600 - 3.900
2.300
0.600 - 3.900
2.240
0.580 - 3.880
2.240
0.580 - 3.880
2.500
0.590 - 3.900
2.400
0.580 - 3.890
2.310
0.580 - 3.890
2.300
0.590 - 3.880
2.310
0.580 - 3.890
2.300
0.600 - 3.900
2.300
0.600 - 3.900
2.240
0.580 - 3.880
2.240
0.580 - 3.880
2.835
0.780 - 4.100
2.835
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
9.84
Power
factor
(%)
99
11.07
99
10.54
99
10.06
99
10.06
99
10.06
99
10.06
99
10.10
99
10.10
99
10.10
99
10.10
99
9.84
99
9.84
99
10.98
99
10.54
99
10.14
99
10.10
99
10.14
99
10.10
99
10.10
99
9.84
99
9.84
99
12.45
99
12.45
99
12.45
99
12.38
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+22+22+50
22+22+22+22+60
22+22+22+22+71
22+22+22+25+25
22+22+22+25+35
22+22+22+25+42
22+22+22+25+50
22+22+22+25+60
22+22+22+25+71
22+22+22+35+35
22+22+22+35+42
22+22+22+35+50
22+22+22+35+60
22+22+22+35+71
22+22+22+42+42
22+22+22+42+50
22+22+22+42+60
22+22+25+25+25
22+22+25+25+35
22+22+25+25+42
22+22+25+25+50
22+22+25+25+60
22+22+25+25+71
22+22+25+35+35
22+22+25+35+42
22+22+25+35+50
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.91
1.91
1.91
1.91
4.36
1.78
1.78
1.78
1.78
4.88
1.66
1.66
1.66
1.66
2.28
2.28
2.58
2.58
2.10
2.10
2.10
2.38
3.32
1.87
1.75
1.98
1.87
1.75
1.98
1.87
1.75
2.26
2.13
1.99
1.85
5.26
1.94
1.94
1.94
3.09
3.09
2.94
1.75
1.75
2.78
3.97
1.64
1.64
1.64
2.61
4.47
1.76
1.67
1.53
1.76
1.67
1.53
1.76
1.67
2.44
3.36
3.19
3.00
4.29
2.22
2.22
2.52
2.52
2.52
2.33
1.94
2.20
2.20
3.72
1.83
1.83
2.08
2.08
4.18
1.60
1.90
1.71
1.60
1.90
1.95
1.82
2.16
1.95
1.82
3.02
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
3.26
1.94
1.71
4.1
3.80
1.57
2.33
(
3.36
1.57
2.04
4.1
4.97
1.57
2.04
(
3.54
1.75
1.53
4.1
4.76
1.63
1.84
(
4.26
1.63
1.84
4.1
3.80
1.63
1.84
(
5.36
2.28
1.98
Total
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
4.68
5.16
3.02
1.81
1.81
2.05
2.88
3.45
1.71
1.71
1.95
2.73
3.90
(
4.1
(
4.1
58
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.815
0.790 - 4.080
2.805
0.800 - 4.070
2.805
0.800 - 4.070
2.835
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.800 - 4.070
2.805
0.800 - 4.070
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.800 - 4.070
2.805
0.780 - 4.100
2.815
0.790 - 4.080
2.800
0.800 - 4.100
2.800
0.800 - 4.100
2.835
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.800 - 4.070
2.805
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
12.36
Power
factor
(%)
99
12.32
99
12.32
99
12.45
99
12.45
99
12.38
99
12.36
99
12.32
99
12.32
99
12.45
99
12.38
99
12.36
99
12.32
99
12.32
99
12.36
99
12.30
99
12.30
99
12.45
99
12.45
99
12.38
99
12.36
99
12.32
99
12.32
99
12.45
99
12.38
99
12.36
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+22+25+35+60
22+22+25+42+42
22+22+25+42+50
22+22+25+42+60
22+22+35+35+35
22+22+35+35+42
22+22+35+35+50
22+22+35+42+42
22+22+35+42+50
22+22+42+42+42
22+25+25+25+25
22+25+25+25+35
22+25+25+25+42
22+25+25+25+50
22+25+25+25+60
22+25+25+25+71
22+25+25+35+35
22+25+25+35+42
22+25+25+35+50
22+25+25+35+60
22+25+25+42+42
22+25+25+42+50
22+25+35+35+35
22+25+35+35+42
22+25+35+35+50
22+25+35+42+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.14
1.14
1.29
4.04
4.39
1.72
1.72
1.96
3.30
3.30
1.64
1.64
1.86
3.13
1.54
1.75
2.94
4.23
1.77
1.77
2.82
2.82
2.82
1.61
1.62
1.69
1.61
1.62
2.69
2.56
2.58
2.69
2.56
3.09
2.95
3.52
1.56
1.56
2.96
2.96
2.96
2.46
2.27
2.27
2.27
3.19
1.89
2.16
2.16
2.16
3.63
1.68
1.57
2.04
1.91
1.79
2.04
1.91
1.79
2.04
1.91
1.79
2.96
2.96
1.78
2.01
2.01
2.82
3.38
2.68
1.80
1.80
2.51
4.31
1.70
1.92
1.92
3.23
3.23
1.75
1.66
1.83
1.97
1.89
1.83
2.76
2.64
3.07
2.76
2.64
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
3.82
1.58
1.61
4.1
5.06
2.11
1.91
(
4.59
2.11
1.91
4.1
4.08
1.86
1.68
(
2.46
2.00
1.80
4.1
3.09
2.45
2.46
(
3.66
1.54
2.46
4.1
3.24
1.54
2.16
(
3.73
1.54
1.69
Total
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
3.66
2.76
3.17
1.68
1.68
2.52
2.52
3.60
1.59
1.80
2.53
3.04
3.04
(
4.1
(
4.1
59
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.805
0.780 - 4.100
2.815
0.790 - 4.080
2.800
0.800 - 4.100
2.800
0.800 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.100
2.805
0.780 - 4.100
2.800
0.800 - 4.100
2.800
0.800 - 4.100
2.800
0.800 - 4.100
2.835
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.800 - 4.070
2.805
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.780 - 4.100
2.815
0.790 - 4.080
2.805
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.100
2.805
0.780 - 4.100
2.805
0.780 - 4.100
12.32
Power
factor
(%)
99
12.36
99
12.30
99
12.30
99
12.45
99
12.38
99
12.32
99
12.30
99
12.30
99
12.30
99
12.45
99
12.45
99
12.38
99
12.36
99
12.32
99
12.32
99
12.45
99
12.38
99
12.36
99
12.32
99
12.36
99
12.32
99
12.45
99
12.38
99
12.32
99
12.32
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Indoor units
combination
22+35+35+35+35
22+35+35+35+42
25+25+25+25+25
25+25+25+25+35
25+25+25+25+42
25+25+25+25+50
25+25+25+25+60
25+25+25+25+71
25+25+25+35+35
25+25+25+35+42
25+25+25+35+50
25+25+25+35+60
25+25+25+42+42
25+25+25+42+50
25+25+35+35+35
25+25+35+35+42
25+25+35+35+50
25+25+35+42+42
Heating capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
1.64
2.59
2.59
2.59
2.59
1.55
2.49
2.49
2.49
2.98
2.40
2.40
2.40
2.40
2.22
2.22
2.22
3.12
2.11
2.11
2.11
2.11
3.56
1.88
1.75
2.00
1.88
1.75
2.00
1.88
1.75
2.00
1.88
1.75
2.90
2.90
1.97
1.97
1.97
2.76
3.33
2.63
1.76
1.76
2.47
4.25
1.88
1.88
1.88
3.18
3.18
1.94
1.85
1.79
1.94
1.85
1.79
2.71
2.59
3.03
2.71
2.59
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
3.76
1.76
1.79
4.1
5.00
2.07
1.87
(
4.48
2.07
1.87
4.1
4.00
2.07
1.87
(
2.40
2.22
2.00
Total
(
4.1
(
4.1
(
4.1
(
4.1
(
4.1
3.60
2.71
3.12
1.76
1.76
2.47
2.47
3.54
1.77
1.77
2.50
2.98
2.98
(
4.1
(
4.1
60
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
12.0
- 14.0
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
) (
Outdoor unit
power consumption
(kW)
2.820
0.780 - 4.100
2.805
0.780 - 4.100
2.835
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.780 - 4.100
2.805
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.100
2.805
0.780 - 4.100
2.805
0.780 - 4.100
2.805
0.780 - 4.100
2.805
0.780 - 4.100
2.835
0.780 - 4.100
2.820
0.780 - 4.090
2.815
0.790 - 4.080
2.805
0.780 - 4.100
12.38
Power
factor
(%)
99
12.32
99
12.45
99
12.45
99
12.38
99
12.36
99
12.32
99
12.32
99
12.45
99
12.38
99
12.32
99
12.32
99
12.32
99
12.32
99
12.45
99
12.38
99
12.36
99
12.32
99
Current
(A)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
5
SPECIFICATION
Outdoor model
MXZ-2A30VA
Single phase
230 V, 50 Hz
2
Max. 20
Max. 15
Refer to 9
Refer to 9
Outdoor unit power supply
System
Indoor units number
m
Piping total length
m
Connecting pipe length
m
Height difference (Indoor ~ Outdoor)
m
Height difference (Indoor ~ Indoor)
Function
kW
Capacity [Rated (Min.-Max.) Hz]
/h
Dehumidification
m3 /h
Outdoor air flow
Breaker capacity
A
Running current
A
Power input
W
Power factor
%
Starting current
A
Compressor motor current
A
Fan motor current
A
Coefficient of performance(C.O.P) 2
Capacity
Cooling
3.0 (1.1 - 4.0)
—
1,950
10
Special
remarks
Fan
motor
Compressor
2 Electrical
data
2.87
595
Output
Winding
resistance (at 20 °C)
Model
Winding
resistance (at 20 °C)
Dimensions W x H x D
Weight
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity (R410A)
Refrigeration oil (Model)
3.6
745
90
3.60
2.67
3.40
0.2
5.04
E1
Model
Heating
4.0 (1.0 - 4.5)
—
1,950
5.37
KNB092FEDH
KNB073FGDH
750
U-V 1.70
V-W 1.70 W-U 1.70
RC0J50-CF
BLK-WHT 14.2
WHT-RED 14.2 RED-BLK 14.2
800 x 550 x 285
34
E2
W
Ω
Ω
mm
kg
dB
rpm
46/44
850/650
47/46
850/650
2
kg
1.15
cc
320 (NEO22)
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
HEATING INDOOR Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
61
MXZ-2A40VA - E1
Single phase
230 V, 50 Hz
2
Max. 30
Max. 20
Refer to 9
Refer to 9
Heating
Cooling
4.5 (1.0 - 5.0)
4.0 (1.1 - 4.5)
—
—
1,860
1,860
15
4.32
4.78
945
1,045
95
4.78
4.12
4.58
0.2
4.76
3.83
SNB130FKCH
1,100
U-V 0.64
V-W 0.64 W-U 0.64
RC0J50-CF
BLK-WHT 14.2
WHT-RED 14.2 RED-BLK 14.2
800 x 550 x 285
40
48/47
47/44
850/490
850/530
2
MXZ-2A40VA - E2
Single phase
230 V, 50 Hz
2
Max. 30
Max. 20
Refer to 9
Refer to 9
Heating
Cooling
4.5 (1.0 - 5.0)
4.0 (1.1 - 4.5)
—
—
1,950
1,950
15
4.78
4.32
945
1,045
95
4.78
4.58
4.12
0.2
3.83
4.76
KNB092FEDH
1,100
U-V 1.70
V-W 1.70 W-U 1.70
RC0J50-CF
BLK-WHT 14.2
WHT-RED 14.2 RED-BLK 14.2
800 x 550 x 285
34
47/44
48/47
850/650
850/650
2
kg
1.3
1.15
cc
450 (NEO22)
320 (NEO22)
Outdoor model
Outdoor unit power supply
System
kW
/h
m3 /h
A
A
W
%
A
A
A
Special
remarks
Fan
motor
Compressor
2 Electrical
data
m
m
m
m
Capacity
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min.-Max.) Hz]
Dehumidification
Outdoor air flow
Breaker capacity
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P) 2
Model
Output
Winding
resistance(at 20 °C)
Model
Winding
resistance(at 20 °C)
Dimensions W x H x D
Weight
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigeration oil (Model)
W
Ω
Ω
mm
kg
dB
rpm
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
HEATING INDOOR Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
62
Outdoor model
Outdoor unit power supply
System
kW
/h
m3 /h
A
A
W
%
A
A
A
2 Electrical
data
m
m
m
m
Capacity
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min.-Max.) Hz]
Dehumidification
Outdoor air flow
Breaker capacity
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P) 2
MXZ-2A52VA
Single phase
230 V, 50 Hz
2
Max. 30
Max. 20
Refer to 9
Refer to 9
Cooling
Heating
6.4 (1.0 - 7.2)
5.2 (1.1 - 6.0)
—
—
1,860
1,860
15
7.64
6.75
1,705
1,505
97
7.64
7.44
6.55
0.2
3.75
3.46
E1
SNB130FKCH
E2
SNB130FKMH
Special
remarks
Fan
motor
Compressor
Model
Output
W
1,400
Winding
resistance(at 20 °C)
Ω
U-V 0.64
V-W 0.64 W-U 0.64
MXZ-3A54VA
Single phase
230 V, 50 Hz
2 to 3
Max. 50
Max. 25
Refer to 9
Refer to 9
Heating
Cooling
6.8 (2.6-9.0)
5.4 (2.9-6.8)
—
—
2,470
2,525
25
6.39
5.69
1,455
1,295
99
6.39
6.19
5.49
0.2
4.67
4.17
E1 , E2
SNB130FLDH1
SNB130FLEH1
E3
SNB130FGBH1
E4 , E5 , E6
SNB130FGBH1T
E7
1,400
U-V 0.45
E1 , E2 , E3
V-W 0.45 W-U 0.45
E4 , E5 , E6 , E7
U-V 0.98
V-W 0.98 W-U 0.98
RC0J50-CF
BLK-WHT 14.2
WHT-RED 14.2 RED-BLK 14.2
800 x 550 x 285
40
50/48
49/45
850/490
850/530
2
RC0J60-AA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
840 x 710 x 330
57
46/44
48/47
650/510
640/510
2
kg
1.3
2.7
cc
450 (NEO22)
Model
Winding
resistance(at 20 °C)
Dimensions W x H x D
Weight
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity(R410A)
mm
kg
dB
rpm
Refrigeration oil (Model)
Ω
E1 , E2 , E3
E4 , E5 , E6 , E7
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
HEATING INDOOR Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
63
600 (NEO22)
700 (NEO22)
Outdoor model
Outdoor unit power supply
System
kW
/h
m3 /h
A
A
W
%
A
A
A
2 Electrical
data
m
m
m
m
Capacity
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min.-Max.) Hz]
Dehumidification
Outdoor air flow
Breaker capacity
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P) 2
Fan
motor
Compressor
Model
Output
Winding
resistance (at 20 °C)
Model
Winding
resistance (at 20°C)
Dimensions W x H x D
Special
remarks
Weight
W
MXZ-4A71VA
Single phase
230 V, 50 Hz
2 to 4
Max. 60
Max. 25
Refer to 9
Refer to 9
Heating
Cooling
8.6 (3.4-9.0)
7.1 (3.7-8.8)
—
—
2,790
2,525
25
8.56
8.48
1,950
1,930
99
8.56
8.36
8.28
0.2
4.41
3.68
E1 , E2
SNB130FLDH1
E3
SNB130FLEH1
E4 , E5 , E6
SNB130FGBH1
SNB130FGBH1T
E7
2,000
E1 , E2 , E3
U-V 0.45
V-W 0.45 W-U 0.45
E4 , E5 , E6 , E7
U-V 0.98
V-W 0.98 W-U 0.98
Ω
mm
RC0J60-AA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
840 x 710 x 330
kg
58
Ω
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity (R410A)
dB
rpm
Refrigeration oil (Model)
cc
E1 , E2 , E3
2,100
U-V 1.41
V-W 1.41 W-U 1.41
2
2.7
3.5
50/48
700/510
600 (NEO22)
700 (NEO22)
E4 , E5 , E6 , E7
TNB220FMCH
PM8H60-UA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
900 x 900 x 320
70
E1
67
E2
48/46
46/44
590/400
560/400
2
48/45
650/510
kg
MXZ-4A80VA
Single phase
230 V, 50 Hz
2 to 4
Max. 70
Max. 25
Refer to 9
Refer to 9
Heating
Cooling
9.4 (3.4-11.6)
8.0 (3.7-9.2)
—
—
2,630
2,530
25
8.48
9.62
1,930
2,190
99
9.62
8.28
9.42
0.2
4.87
3.65
870 (NEO22)
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
HEATING INDOOR Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
64
MXZ-5A100VA
Single phase
230 V, 50 Hz
2 to 5
Max. 80
Max. 25
Refer to 9
Refer to 9
Outdoor model
Outdoor unit power supply
System
kW
/h
m3 /h
A
A
W
%
A
A
A
Special
remarks
Fan
motor
Compressor
2 Electrical
data
m
m
m
m
Capacity
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min.-Max.) Hz
Dehumidification
Outdoor air flow
Breaker capacity
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P) 2
Model
Output
Winding
resistance(at 20 °C)
Model
Winding
resistance(at 20 °C)
Dimensions W x H x D
Weight
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigeration oil (Model)
Heating
12 (3.4 - 14)
—
3,558
Cooling
10 (3.7 - 11)
—
3,396
25
12.45
2,835
12.88
2,935
99
12.88
12.25
12.68
0.2
4.23
3.41
TNB220FMCH
2,700
U-V 1.41
V-W 1.41 W-U 1.41
PM8H60-UA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
900 x 900 x 320
68
W
Ω
Ω
mm
kg
dB
rpm
54/46
700/500
51/45
700/500
2
kg
4.0
cc
870 (NEO22)
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
HEATING INDOOR Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
65
NOISE CRITERIA CURVES
6
MXZ-2A30VA
MXZ-2A40VA
FAN SPEED FUNCTION SPL(dB(A))
High
Cooling
46
High
Cooling
47
High
Heating
47
High
Heating
48
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
63
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-20
10
10
125
250
500
1000
2000
4000
63
8000
125
MXZ-2A52VA
FAN SPEED FUNCTION SPL(dB(A))
500
1000
2000
4000
LINE
MXZ-3A54VA
FAN SPEED FUNCTION SPL(dB(A))
High
Cooling
49
High
Cooling
46
High
Heating
50
High
Heating
48
90
8000
LINE
90
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
250
BAND CENTER FREQUENCIES, Hz
BAND CENTER FREQUENCIES, Hz
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
LINE
90
90
20
FAN SPEED FUNCTION SPL(dB(A))
LINE
80
70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-20
10
NC-70
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-20
10
63
125
250
500
1000
2000
4000
8000
63
BAND CENTER FREQUENCIES, Hz
125
250
500
1000
2000
BAND CENTER FREQUENCIES, Hz
66
4000
8000
MXZ-4A71VA
FAN SPEED FUNCTION SPL(dB(A))
LINE
MXZ-4A80VA
Cooling
48
High
Cooling
46
High
Heating
50
High
Heating
48
LINE
90
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
FAN SPEED FUNCTION SPL(dB(A))
High
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-20
10
63
80
125
250
500
1000
2000
4000
NC-20
10
8000
63
BAND CENTER FREQUENCIES, Hz
125
250
500
1000
2000
4000
8000
BAND CENTER FREQUENCIES, Hz
FAN SPEED FUNCTION SPL(dB(A))
MXZ-5A100VA
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
High
Cooling
51
High
Heating
54
LINE
OUTDOOR UNIT
1m
90
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
MICROPHONE
80
70
NC-70
60
Test conditions
Cooling :Dry-bulb temperature 35°C Wet-bulb temperature 24°C
Heating :Dry-bulb temperature 7°C Wet-bulb temperature 6°C
NC-60
50
NC-50
40
NC-40
30
NC-30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-20
10
63
125
250
500
1000
2000
4000
8000
BAND CENTER FREQUENCIES, Hz
67
7
OUTLINES AND DIMENSIONS
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
Unit: mm
REQUIRED SPACE
400
Drainage hole
Basically open 100mm or more
without any obstruction in front
and on both sides of the unit.
ore
or m
mm
100
42
100
44
mm
or m
17.5
Air in
344.5
304 325
ore
ore
or m
mm
200
350
mm
ore
40
Open two sides of left,
right, or rear side.
Air out
2-10x21 Oval hole
22.3
23
285
13
10
251.1
280
51 51 51
550
handle
302.5
150
Liquid pipe :
Gas pipe :
Liquid pipe :
Gas pipe :
170.4
500
800
69
68
6.35(flared)1/4
9.52(flared)3/8
6.35(flared)1/4
9.52(flared)3/8
or m
B unit
connection
A unit
connection
MXZ-3A54VA -
E1
,
,
E2
E3
,
Unit: mm
E4
REQUIRED SPACE
Open as a rule
More than 500 mm
if the front and both
sides are open
More than 100 mm
More than 200 mm if
there are obstacles to
both sides
More than 100 mm
500
Air out
Open as a rule
More than 500 mm if
the back, both sides
and top are open
More than 350 mm
396
17.7
17.7
16.8
360.6
38
Air in
4-10 x 21 Oval hole
Drainage holes 3- 33
840
Indoor and
outdoor
connect wiring
39 x 27 hole
30
30
330
27.1
13
Gas pipe
9.52(flared)3/8(A,B,C unit)
710
66.3
440
B unit connection
121
A unit connection
25
84
45
225
C unit connection
360
Air in
288
31
233.1
31.3
63.2
23.1
Liquid pipe
6.35(flared)1/4
69
,
E6
169
500
233.1
31.3
171
288
Air in
20.3
16.8
63.2
Unit: mm
E7
13.3
Air in
17.7
3- 33 Drain hole
396
,
360.6
(Bolt Pitch)
E5
17.7
MXZ-3A54VA -
Air out
4-10 x 21 Oval hole
(Base bolt M10)
840
30
200
30
330
13
240
27.1
Indoor and outdoor
connect wiring
39 x 27 hole
710
66.3
Gas pipe
9.52(flared)3/8
440
225
45
360
C unit connection
B unit connection
84
A unit connection
299
Liquid pipe
23.1
6.35(flared)1/4
More than
100
More than
200
More than
100
2.Service space
Note : Leave front and overhead
clearance fully.
More than
350
Note : Leave rear, overhead and
both sides clearance fully.
More than
100
More than
350
More than
500
More than
100
More than
350
Service space
70
More than
500
Note : Leave front and both sides
clearance fully.
More than
500
1.Installation space
MXZ-4A71VA -
E1
,
E2
,
E3
,
Unit: mm
E4
REQUIRED SPACE
Open as a rule
More than 500 mm
if the front and both
sides are open
More than 100 mm
More than 200 mm if
there are obstacles to
both sides
More than 100 mm
500
Air out
More than 350 mm
396
17.7
17.7
16.8
360.6
38
Air in
4-10 x 21 Oval hole
Drainage holes 3- 33
840
Indoor and
outdoor
connect wiring
39 x 27 hole
30
30
330
13
Gas pipe
27.1
C unit connection
B unit connection
A unit connection
25
84
121
9.52(flared)3/8(B,C,D unit)
12.7(flared)1/2(A unit)
D unit connection
440
315
45
710
66.3
360
Air in
288
31
233.1
31.3
63.2
Open as a rule
More than 500 mm if
the back, both sides
and top are open
23.1
Liquid pipe
6.35(flared)1/4
71
E6
,
500
31.3
171
288
Air in
20.3
16.8
233.1
17.7
169
63.2
Unit: mm
E7
13.3
Air in
17.7
3- 33 Drain hole
396
,
E5
360.6
(Bolt Pitch)
MXZ-4A71VA -
Air out
4-10 x 21 Oval hole
(Base bolt M10)
840
30
200
30
330
13
240
27.1
66.3 Gas pipe
9.52(flared)3/8(B,C,D unit)
12.7(flared)1/2(A unit)
D unit connection
710
Indoor and outdoor
connect wiring
39 x 27 hole
440
45
360
315
C unit connection
B unit connection
84
A unit connection
299
23.1
Liquid pipe
6.35(flared)1/4
Note : Leave front and both sides
clearance fully.
More than
500
1.Installation space
More than
100
Note : Leave front and overhead
clearance fully.
More than
350
Note : Leave rear, overhead and
both sides clearance fully.
More than
100
More than
350
More than
500
More than
100
More than
350
Service space
72
More than
500
More than
100
More than
200
2.Service space
200
500
250
270
Unit: mm
(200)
Air in
35
35
E1
2-U-shape notched holes
(Base bolt M10)
(27)
(16)
MXZ-4A80VA -
40
(16)
74
355
387
Air in
Air out
Drainage holes 3- 33
2-12 x 36 Oval hole
(Base bolt M10)
Gas pipe
9.52(flared)3/8(B,C,D unit)
12.7(flared)1/2(A unit)
900
320
30
900
88
23
480.8
531.3
D unit connection
C unit connection
B unit connection
A unit connection
33
317
350
460
50
Indoor and
outdoor
connect wiring
26 x 45 hole
10
23
Liquid pipe
6.35(flared)1/4
More than
100
More than
200
More than
100
2.Service space
Note : Leave front and overhead
clearance fully.
More than
350
Note : Leave rear, overhead and
both sides clearance fully.
More than
100
More than
350
More than
500
More than
100
More than
350
Service space
73
More than
500
Note : Leave front and both sides
clearance fully.
More than
500
1.Installation space
MXZ-5A100VA
200
Unit: mm
200
2-U Shaped notched hole
(Base bolt M10)
Air out
355
(Bolt pitch)
387
11
Air in
16
270
250
35
74
35
500
27
E2
40
MXZ-4A80VA -
3- 33 Drain hole
16
24
Air in
Gas pipe
9.52(flared) 3/8 (B,C,D,E (MXZ-5A100VA) unit)
12.7(flared) 1/2 (A unit)
2-12 x 36 Oval hole
(Base bolt M10)
30
900
45
460
Indoor and
outdoor
connect
wiring
(35 x 53) hole
10
88
E unit connection (MXZ-5A100VA)
D unit connection
C unit connection
B unit connection
A unit connection
900
405
Handle
597
Handle
320
B
132
A
23
317
Liquid pipe
6.35(flared)1/4
More than
100
More than
200
More than
100
2.Service space
Note : Leave front and overhead
clearance fully.
More than
350
Note : Leave rear, overhead and
both sides clearance fully.
More than
100
More than
350
More than
500
More than
100
More than
350
Service space
74
More than
500
Note : Leave front and both sides
clearance fully.
More than
500
1.Installation space
75
12-24V
230V~
12-24V
230V~
S3 TB2
S2
S1
S3 TB3
S2
S1
N TB1
BLK
GRN/YLW
BLK
BLU
L65
BLU
BLK
RED
BLU
ORN
BLK
GRN
SYMBOL
NAME
CT61,CT761,CT781 CURRENT TRANSFORMER
C63A,C63B,C63C SMOOTHING CAPACITOR
DB61,DB65 DIODE MODULE
F61 FUSE (T20AL250V)
F64,F801,F901 FUSE (T3.15AL250V)
IC801 INTELLIGENT POWER DEVICE
IPM,IC932 INTELLIGENT POWER MODULE
L64,L65 REACTOR
MC COMPRESSOR
TO INDOOR
UNIT No.A
CONNECTING
TO INDOOR
UNIT No.B
CONNECTING
CIRCUIT BREAKER
L
PE
POWER P.C.
BOARD
F61
NF
RT68
SYMBOL
MF
NF
NR64
RT61
RT62
RT64
RT65
NR64
F64
X64
R64B
4
DISPLAY
P.C. BOARD
LED1 LED2
SSR61
R64A
CT61
SW1
CN936
CN934
CN912
3
1
2
TAB4
NAME
OUTDOOR FAN MOTOR
NOISE FILTER
VARISTOR
DEFROST THERMISTOR
DISCHARGE TEMPERATURE THERMISTOR
FIN TEMPERATURE THERMISTOR
AMBIENT TEMPERATURE THERMISTOR
OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
CN938
1
2 CN602
3
1 CN601
2
3 INTERFACE
4
5 P.C. BOARD
LDE
TAB2
TAB1
BLU
BLK
LD69
LD70
CN935
CN937
CN933
R831
RT61 RT62 RT68
CN661
1 2 3 4 5 6
DB65
DB61
C63B
C63A
C63C
+
IC801
T801
F801
RT65
CN663
1 2
LEV A
CN791
R62
F901
R61
6
W
V
U
IPM
W
V
U
IC932
N
P
N
P
LEV B
CN792
CT781
CT761
6
1
2
3
CN932
C
N
9
3
1
LDU
LDV
LDW
5
BLK
BLK
WHT 1 WHT
2
RED 3 RED
CN61
W
MF
MC
V
U
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
RT64
CN662
1 2
INVERTER P.C. BOARD
TR821
+
+
NAME
CURRENT-DETECTING RESISTOR
RESISTOR
TERMINAL BLOCK
SWITCHING POWER TRANSISTOR
SWITCHING TRANS
RELAY
R.V. COIL
EXPANSION VALVE
SOLENOID COIL RELAY
7
6
7
21S4
L64
SYMBOL
R61,R62,R831
R64A,R64B
TB1,TB2,TB3
TR821
T801
X64
21S4
LEV A,LEV B
SSR61
BLK
MXZ-2A30VA MXZ-2A40VA
BLU
POWER SUPPLY
~/N
230V 50Hz
BLK
8
WIRING DIAGRAM
MXZ-2A52VA
SYMBOL
CB1~3
CT1, 2
CT61
F64
F801
F911
HC930
IPM
L
LEV A~C
LEV E
S3
S2
S1
TB2
S3
S2
S1
TB3
BLK
BLU
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T3.15AL250V)
FUSE (T1AL250V)
INTELLIGENT POWER MODULE
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
EXPANSION VALVE
230V~
TO INDOOR
UNIT No.A
12-24V
CONNECTING
230V~
TO INDOOR
UNIT No.B
12-24V
CONNECTING
230V~
S3
S2
S1
TB4
L
N
CIRCUIT
BREAKER
TO INDOOR
UNIT No.C
12-24V
CONNECTING
POWER
SUPPLY
~/N
230V~
50Hz
BLK
BLU
BLK
BLU
LEV A
LEV B
1 2 3 4 5
CN901
R64B
1 2 3 4 5
CN781
2
WHT 1
TAB4
BLK
BLK
BLK
4
BLK 3
3
LEV C
S
YLW
1 2
CN4
RT68
RT61
RT62
CN661
1 2 3 4 5 6 7 8
RT65
F801
LD2
CN795
1 2 3 4 5 6
T801
RS2
RS1
CB1
LEV E
RS4
RS3
CB3
R937B
R937A
1 2 3 CN801
LD1
CB2
POWER BOARD
CT2
HC930
GRN
LD9
IPM
CT1
W
V
U
CN932
CN931
MC
YLW
BLU
ORN
PNK
GRY
BLK
WHT
RED
BLK
BLK
RED
WHT
BLK
U
V
W
MF
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
CN663
1 2
1 2
CN701
RT6A
RT6C
RT6B
CN662
1 2 3 4 5 6 7 8
R
RED
1 2 3 4 5 6 7
CN702
ELECTRONIC CONTROL P.C. BOARD
21S4
(BLU)
CN793
1 2 3 4 5 6
GRN
GRN
SSR61
NR64
R64A
1 2 CN912
(RED)
CN792
1 2 3 4 5 6
LDE2
LDE1
F911
CT61
(WHT)
CN791
1 2 3 4 5 6
CN61
N/F
N
NAME
SYMBOL
NAME
SYMBOL
MC
COMPRESSOR
RT64 FIN TEMPERATURE THERMISTOR
OUTDOOR FAN MOTOR
MF
RT65 AMBIENT TEMPERATURE THERMISTOR
NR64 VARISTOR
RT68 OUTDOOR HEAT EXCHANGER
N/F NOISE FILTER
TEMPERATURE THERMISTOR
PFC POWER FACTOR CONTROLLER
SSR61 SOLENOID COIL RELAY
R64A,B RESISTOR
T801 TRANSFORMER
R937A, B RESISTOR
TB1~4 TERMINAL BLOCK
RS1~4 RESISTOR
X64 RELAY
RT6A~C GAS PIPE TEMPERATURE THERMISTOR 21S4 R.V. COIL
RT61 DEFROST THERMISTOR
RT62 DISCHARGE TEMPERATURE THERMISTOR
BLK
BLU
RED
ORN
YLW
TAB2
TAB1
F64
X64
L
PFC
WHT
GRN/YLW
BLK
BLU
PE
1 2 3
1 2 3
BLU
NOISE FILTER
P.C. BOARD
BLK
GROUND
RED
RT64
TB1
CN603
CN602
CN601
BRN
BLU
ORN
YLW
WHT
BLK
BLK
BLK
GRY
GRY
GRY
GRY
GRY
GRY
3 2 1
BRN
BLU
ORN
YLW
WHT
RED
BLK
BLK
BLK
CN5
GRY
GRY
BLK
BLK
1 2 3 4 5
BLU
BRN
BLU
ORN
YLW
WHT
RED
BLK
2 1
7 6 5 4 3 2 1
CN2
BLK
BLK
GRY
GRY
76
GRY
GRY
1 2
CN902
RED
1 2
CN903
RED
,
BRN
BLU
ORN
YLW
WHT
E2
CN3
1 2
,
3 2 1
E1
5 4 3 2 1
MXZ-3A54VA E3
SYMBOL
CB1~3
CT1, 2
CT61
F64
F801
F911
HC930
IPM
L
LEV A~C
LEV E
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T3.15AL250V)
FUSE (T1AL250V)
INTELLIGENT POWER MODULE
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
EXPANSION VALVE
NAME
SYMBOL
NAME
SYMBOL
MC
COMPRESSOR
RT65 AMBIENT TEMPERATURE THERMISTOR
OUTDOOR FAN MOTOR
MF
RT68 OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
NR64 VARISTOR
N/F NOISE FILTER
SSR61 SOLENOID COIL RELAY
PFC POWER FACTOR CONTROLLER
T801 TRANSFORMER
R64A,B RESISTOR
TB1~4 TERMINAL BLOCK
R937A, B RESISTOR
X64 RELAY
21S4 R.V. COIL
RS1~4 RESISTOR
RT61 DEFROST THERMISTOR
RT62 DISCHARGE TEMPERATURE THERMISTOR
RT64 FIN TEMPERATURE THERMISTOR
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
MXZ-3A54VA E4
77
78
230V~
12-24V
TB2
230V~
12-24V
TB3
230V~
12-24V
TB4
CIRCUIT
BREAKER
S3
S2
S1
S3
S2
S1
S3
S2
S1
L
N
BLU
BLK
BLK
RED
ORN
YLW
BLK
BLU
RED
BLK
BLU
ORN
BLK
BLU
YLW
BLU
BLU
BLK
CN61
TAB2
TAB1
1
CN601
5
3
CN602
1
3
CN603
1
1
3
N/F
F65
SYMBOL
CB1~3
CT1,2
CT61
F64
F65
F801
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE(T2AL250V)
FUSE(T6.3AL250V)
FUSE(T3.15AL250V)
SYMBOL
HC930
IPM
L
LEV A~C
LEV E
MC
LDE1
N/F
SSR61
2
21S4
PTC64
PTC65
NR64
CN912
1
U
F64
1
CN901
1
CN781
5
5
CN903
1
2
CN902
1
2
TAB4
3
1
WHT
BLK
NAME
FAN MOTOR
VARISTOR
NOISE FILTER
POWER FACTOR CONTROLLER
CIRCUIT PROTECTION
RESISTOR
LEV B
LEV A
SYMBOL
MF
NR64
N/F
PFC
PTC64,65
R937A,B
M
6
(RED)
CN792
M
6
(WHT)
CN791
ELECTRONIC CONTROL P.C.BOARD
NAME
INTELLIGENT POWER MODULE
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
EXPANSION VALVE
COMPRESSOR
NOTES: 1. About the indoor side electric wiring refer to
the indoor unit electric wiring diagram for servicing.
2. Use copper conductors only (For field wiring).
3. Symbols below indicate.
:Terminal block
:Connector
TO INDOOR
UNIT No.A
CONNECTING
TO INDOOR
UNIT No.B
CONNECTING
TO INDOOR
UNIT No.C
CONNECTING
POWER SUPPLY
~/N 230V 50Hz
CT61
BLK
BLK
BLK
GRN/YLW
BLK
PE
BLK
X64
CN702
7
BLK
BLK
BLK
BLK
BLK
BLK
BLK
YLW
RED
LEV C
M
6
7
CN2
1
1
2
LED2
CN5
S
R
2
RT61
1
LED1
CN701
1
2
1
CN4
RT62
LD2
F801
RT68
CN661
T801
RS2
RS1
1
8
CB1
CB2
RT65
1
CB3
+
SYMBOL
SSR61
T801
TB1~4
X64
21S4
2
R937B
R937A
RS4
RS3
+
CN663
3
CN801
LD1
+
POWER BOARD
NAME
RESISTOR
DEFROST THERMISTOR
DISCHARGE TEMP.THERMISTOR
FIN TEMP.THERMISTOR
AMBIENT TEMP.THERMISTOR
OUTDOOR HEAT EXCHANGER TEMP.THERMISTOR
LED3
(BLU)
CN793
2
4
SYMBOL
RS1~4
RT61
RT62
RT64
RT65
RT68
1
3
L
PFC
GRN
NOISE FILTER P.C.BOARD
WHT
TB1
BLK
LEV E
M
6
CN3
W
1
3
5
YLW
BLU
ORN
PNK
GRY
BLK
WHT
RED
RED
WHT V
V
U
MS
3~
MF
8
RT64
W
MS
3~
MC
BLK
U
CN932
1
CN931
CN795
HC930
2
1
CT2
CT1
NAME
SOLENOID COIL RELAY
TRANSFORMER
TERMINAL BLOCK
RELAY
REVERSING VALVE SOLENOID COIL
LD9
IPM
,
BLK
E5
RED
MXZ-3A54VA E6
MXZ-3A54VA -
E7
79
230V~
S3
S2
S1
TB2
S3
S2
S1
TB3
S3
S2
S1
TB4
S3
S2
S1
TB5
BLK
BLU
BLK
BLU
RED
ORN
YLW
BRN
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T3.15AL250V)
FUSE (T1AL250V)
INTELLIGENT POWER MODULE
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
EXPANSION VALVE
230V~
TO INDOOR
UNIT No.A
12-24V
CONNECTING
230V~
TO INDOOR
UNIT No.B
12-24V
CONNECTING
230V~
TO INDOOR
UNIT No.C
12-24V
CONNECTING
SYMBOL
CB1~3
CT1, 2
CT61
F64
F801
F911
HC930
IPM
L
LEV A~D
LEV E
PE
L
N
CIRCUIT
BREAKER
TO INDOOR
UNIT No.D
12-24V
CONNECTING
POWER
SUPPLY
~/N
230V~
50Hz
TAB2
TAB1
CN901
1 2 3 4 5
1 2 3 4 5
CN781
1 2 3 4 5 6 7
CN702
S
CN4
1 2
SYMBOL
MC
MF
NR64
N/F
PFC
R64A,B
R937A, B
RS1~4
RT6A~D
RT61
RT62
LEV A
LEV C
LEV D
RT68
RT61
RT62
RT6A
RT6C
RT6B
RT6D
CN663
1 2
RT65
RS2
RS1
LD2
CB1
F801
R937B
R937A
CT2
HC930
GRN
LD9
IPM
CT1
W
V
U
CN932
CN931
MC
YLW
BLU
ORN
PNK
GRY
BLK
WHT
RED
BLK
BLK
RED
WHT
BLK
U
V
W
MF
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
LEV E
RS4
RS3
CB3
1 2 3 CN801
LD1
CB2
POWER BOARD
CN795
1 2 3 4 5 6
T801
PFC
NAME
SYMBOL
NAME
RT64 FIN TEMPERATURE THERMISTOR
COMPRESSOR
OUTDOOR FAN MOTOR
RT65 AMBIENT TEMPERATURE THERMISTOR
VARISTOR
RT68 OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
NOISE FILTER
SSR61 SOLENOID COIL RELAY
POWER FACTOR CONTROLLER
RESISTOR
T801 TRANSFORMER
RESISTOR
TB1~5 TERMINAL BLOCK
RESISTOR
X64 RELAY
GAS PIPE TEMPERATURE THERMISTOR 21S4 R.V. COIL
DEFROST THERMISTOR
DISCHARGE TEMPERATURE THERMISTOR
LEV B
CN661
1 2 3 4 5 6 7 8
CN662
1 2 3 4 5 6 7 8
1 2
CN701
(GRN)
CN794
1 2 3 4 5 6
ELECTRONIC CONTROL P.C. BOARD
21S4
CN912
YLW
(BLU)
CN793
1 2 3 4 5 6
GRN
GRN
1 2
SSR61
BLK
BLK
BLK
2
WHT 1
TAB4
R
(RED)
CN792
1 2 3 4 5 6
LDE2
LDE1
F911
CT61
NR64
R64A R64B
RED
(WHT)
CN791
1 2 3 4 5 6
CN61
N/F
F64
4
BLK 3
3
L
RED
BRN
BLU
ORN
YLW
WHT
WHT
GRN/YLW
BLU
RED
BRN
BLU
ORN
YLW
WHT
BLK
BLU
3 2 1
RED
BRN
BLU
ORN
YLW
WHT
GROUND
CN604
N
RED
BRN
BLU
ORN
YLW
WHT
RT64
TB1
BLU
BLK
1 2 3
CN603
1 2 3
1 2 3
BLU
X64
BLK
NOISE FILTER
P.C. BOARD
BLK
BLK
BLK
GRY
GRY
BLK
BLK
BLK
BLU
BLK
BLU
BLK
BLK
BLK
CN5
GRY
GRY
GRY
GRY
GRY
GRY
GRY
GRY
CN601
CN602
1 2 3 4 5
BLK
2 1
7 6 5 4 3 2 1
CN2
BLK
BLK
GRY
GRY
80
GRY
GRY
1 2
CN902
RED
1 2
CN903
RED
,
BRN
BLU
ORN
YLW
WHT
E2
CN3
1 2
,
3 2 1
E1
5 4 3 2 1
MXZ-4A71VA E3
SYMBOL
CB1~3
CT1, 2
CT61
F64
F801
F911
HC930
IPM
L
LEV A~D
LEV E
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T3.15AL250V)
FUSE (T1AL250V)
INTELLIGENT POWER MODULE
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
EXPANSION VALVE
SYMBOL
MC
MF
NR64
N/F
PFC
R64A,B
R937A, B
RS1~4
RT61
RT62
RT64
NAME
COMPRESSOR
OUTDOOR FAN MOTOR
VARISTOR
NOISE FILTER
POWER FACTOR CONTROLLER
RESISTOR
RESISTOR
RESISTOR
DEFROST THERMISTOR
DISCHARGE TEMPERATURE THERMISTOR
FIN TEMPERATURE THERMISTOR
SYMBOL
NAME
RT65 AMBIENT TEMPERATURE THERMISTOR
RT68 OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
SSR61 SOLENOID COIL RELAY
T801 TRANSFORMER
TB1~5 TERMINAL BLOCK
X64 RELAY
21S4 R.V. COIL
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
MXZ-4A71VA E4
81
82
230V~
12-24V
TB2
230V~
12-24V
TB3
230V~
12-24V
TB4
230V~
12-24V
TB5
CIRCUIT
BREAKER
S3
S2
S1
S3
S2
S1
S3
S2
S1
S3
S2
S1
L
N
BLU
BLK
BLK
RED
ORN
YLW
BLU
RED
BLK
BLU
ORN
BLK
BLU
BRN
BLK
BLK
YLW
BLU
BLU
BRN
BLU
BLK
CN61
TAB2
1
CN601
3
CN604
1
3
CN603
1
3
CN602
1
5
1
3
N/F
F65
SYMBOL
CB1~3
CT1,2
CT61
F64
F65
F801
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE(T2AL250V)
FUSE(T6.3AL250V)
FUSE(T3.15AL250V)
SYMBOL
HC930
IPM
L
LEV A~D
LEV E
MC
LDE1
N/F
SSR61
2
CT61
21S4
PTC64
PTC65
NR64
CN912
1
U
F64
1
CN901
1
CN781
5
5
CN903
1
2
CN902
1
2
TAB4
3
1
WHT
BLK
LEV C
M
6
(BLU)
CN793
NAME
FAN MOTOR
VARISTOR
NOISE FILTER
POWER FACTOR CONTROLLER
CIRCUIT PROTECTION
RESISTOR
LEV B
LEV A
SYMBOL
MF
NR64
N/F
PFC
PTC64,65
R937A,B
M
6
(RED)
CN792
M
6
(WHT)
CN791
ELECTRONIC CONTROL P.C.BOARD
NAME
INTELLIGENT POWER MODULE
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
EXPANSION VALVE
COMPRESSOR
NOTES: 1. About the indoor side electric wiring refer to
the indoor unit electric wiring diagram for servicing.
2. Use copper conductors only (For field wiring).
3. Symbols below indicate.
: Terminal block
: Connector
TO INDOOR
UNIT No.A
CONNECTING
TO INDOOR
UNIT No.B
CONNECTING
TO INDOOR
UNIT No.C
CONNECTING
TO INDOOR
UNIT No.D
CONNECTING
POWER SUPPLY
~/N 230V 50Hz
TAB1
BLK
BLK
BLK
GRN/YLW
BLK
PE
BLK
X64
CN702
2
4
SYMBOL
RS1~4
RT61
RT62
RT64
RT65
RT68
1
3
L
7
CN2
1
1
2
LED2
CN5
S
R
2
RT61
1
LED1
CN701
1
2
1
CN4
RT62
LD2
F801
RT68
CN661
T801
RS2
RS1
1
8
CB1
CB2
RT65
1
CB3
+
SYMBOL
SSR61
T801
TB1~5
X64
21S4
2
R937B
R937A
RS4
RS3
+
CN663
3
CN801
LD1
+
POWER BOARD
NAME
RESISTOR
DEFROST THERMISTOR
DISCHARGE TEMP.THERMISTOR
FIN TEMP.THERMISTOR
AMBIENT TEMP.THERMISTOR
OUTDOOR HEAT EXCHANGER TEMP.THERMISTOR
LEV D
M
6
(GRN)
CN794
LED3
7
BLK
BLK
BLK
BLK
BLK
BLK
BLK
YLW
RED
PFC
GRN
NOISE FILTER P.C.BOARD
WHT
TB1
BLK
LEV E
M
6
CN3
W
1
3
5
YLW
BLU
ORN
PNK
GRY
BLK
WHT
RED
RED
WHT V
V
U
MS
3~
MF
8
RT64
W
MS
3~
MC
BLK
U
CN932
1
CN931
CN795
HC930
2
1
CT2
CT1
NAME
SOLENOID COIL RELAY
TRANSFORMER
TERMINAL BLOCK
RELAY
REVERSING VALVE SOLENOID COIL
LD9
IPM
,
BLK
E5
RED
MXZ-4A71VA E6
MXZ-4A71VA -
E7
83
SYMBOL
CB1~3
CT1, 2
CT61
F64
F801
F911
HC930
HPS
IPM
L
LEV A~D
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T3.15AL250V)
FUSE (T1AL250V)
INTELLIGENT POWER MODULE
HIGH PRESSURE SWITCH
INTELLIGENT POWER MODULE
REACTOR
EXPANSION VALVE
SYMBOL
LEV E
MC
MF
NR64
N/F
PFC
R64A,B
R937A, B
RS1~4
RT6A~D
RT61
NAME
SYMBOL
NAME
RT62 DISCHARGE TEMPERATURE THERMISTOR
EXPANSION VALVE
RT64 FIN TEMPERATURE THERMISTOR
COMPRESSOR
OUTDOOR FAN MOTOR
RT65 AMBIENT TEMPERATURE THERMISTOR
VARISTOR
RT68 OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
NOISE FILTER
SSR61 SOLENOID COIL RELAY
POWER FACTOR CONTROLLER
RESISTOR
T801 TRANSFORMER
RESISTOR
TB1~5 TERMINAL BLOCK
RESISTOR
X64 RELAY
GAS PIPE TEMPERATURE THERMISTOR 21S4 R.V. COIL
DEFROST THERMISTOR
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
MXZ-4A80VA E1
84
SYMBOL
CB1~3
CT1, 2
CT61
F64
F65
F801
F931
HC930
HPS
IPM
L
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T6.3AL250V)
FUSE (T3.15AL250V)
FUSE (T3.15AL250V)
INTELLIGENT POWER MODULE
HIGH PRESSURE SWITCH
INTELLIGENT POWER MODULE
REACTOR
SYMBOL
LEV A~D
LEV F
MC
MF
NR64
N/F
PFC
R64A,B
R930A, B
RS1~4
RT61
NAME
EXPANSION VALVE
EXPANSION VALVE
COMPRESSOR
OUTDOOR FAN MOTOR
VARISTOR
NOISE FILTER
POWER FACTOR CONTROLLER
RESISTOR
RESISTOR
RESISTOR
DEFROST THERMISTOR
SYMBOL
NAME
RT62 DISCHARGE TEMPERATURE THERMISTOR
RT64 FIN TEMPERATURE THERMISTOR
RT65 AMBIENT TEMPERATURE THERMISTOR
RT68 OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
SSR61 SOLENOID COIL RELAY
T801 TRANSFORMER
TB1~5 TERMINAL BLOCK
X64 RELAY
21S4 R.V. COIL
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
MXZ-4A80VA E2
85
SYMBOL
CB1~3
CT1, 2
CT61
F64
F65
F801
F931
HC930
HPS
IPM
L
NAME
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
FUSE (T2AL250V)
FUSE (T6.3AL250V)
FUSE (T3.15AL250V)
FUSE (T3.15AL250V)
INTELLIGENT POWER MODULE
HIGH PRESSURE SWITCH
INTELLIGENT POWER MODULE
REACTOR
SYMBOL
LEV A~E
LEV F
MC
MF
NR64
N/F
PFC
R64A,B
R930A, B
RS1~4
RT61
NAME
EXPANSION VALVE
EXPANSION VALVE
COMPRESSOR
OUTDOOR FAN MOTOR
VARISTOR
NOISE FILTER
POWER FACTOR CONTROLLER
RESISTOR
RESISTOR
RESISTOR
DEFROST THERMISTOR
SYMBOL
NAME
RT62 DISCHARGE TEMPERATURE THERMISTOR
RT64 FIN TEMPERATURE THERMISTOR
RT65 AMBIENT TEMPERATURE THERMISTOR
RT68 OUTDOOR HEAT EXCHANGER
TEMPERATURE THERMISTOR
SSR61 SOLENOID COIL RELAY
T801 TRANSFORMER
TB1~6 TERMINAL BLOCK
X64 RELAY
21S4 R.V. COIL
NOTES: 1.About the indoor side electric wiring
refer to the indoor unit electric wiring
diagram for servicing.
2.Use copper conductors only (for field wiring).
3.Symbols below indicate.
:Terminal block
:Connector
MXZ-5A100VA
86
REFRIGERANT SYSTEM DIAGRAM
9
MXZ-2A30VA
UNIT: mm
Compressor
R.V. coil
OFF
ON
Indoor unit
B
Refrigerant flow in cooling
Refrigerant flow in heating
Muffler
4-way valve
Stop valve
(with service port)
Outdoor heat
exchanger
temperature
thermistor
RT68
Stop valve
(with service port)
FAN-OUT
HEX-OUT
Indoor unit
A
Discharge
temperature
thermistor RT62
Capillary tube
Indoor unit
A
Stop valve
(with strainer #100)
Defrost
thermistor
RT61
LEV A
Ambient
temperature
thermistor
RT65
Strainer
#100
Capillary tube
Indoor unit
B
Stop valve
(with strainer #100)
LEV B
MAX REFRIGERANT PIPING LENGTH
Indoor
units
Piping length each indoor unit (a, b)
15m
Total piping length (a+b)
20m
Bending point for each unit
15
Total bending point
20
a
Outdoor
unit
10m
It does not matter which unit is higher.
10m
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit Refrigerant piping length (one way, 2 unit total)
precharged
20m
(g)
10m
b
1,150
0
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
class
22/25
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Gas
9.52(3/8)
Extension pipe diameter
Liquid
Gas
6.35(1/4)
9.52(3/8)
UNIT: mm (inch)
Outdoor unit union diameter
For
Liquid
6.35(1/4)
Indoor unit A
Gas
9.52(3/8)
Liquid
6.35(1/4)
Indoor unit B
Gas
9.52(3/8)
87
MXZ-2A40VA -
E1
MXZ-2A52VA
UNIT: mm
Compressor
R.V. coil
OFF
ON
Indoor unit
B
Muffler
4-way valve
Stop valve
(with service port)
Outdoor heat
exchanger
temperature
thermistor
RT68
Stop valve
(with service port)
FAN-OUT
HEX-OUT
Indoor unit
A
Discharge
temperature
thermistor RT62
Refrigerant flow in cooling
Refrigerant flow in heating
Ambient
temperature
thermistor
RT65
Defrost
thermistor
RT61
Capillary tube
Indoor unit
A
Capillary tube
Stop valve
(with strainer #100)
LEV A
Strainer
#100
Distributor
Capillary tube
Indoor unit
B
Stop valve
(with strainer #100)
LEV B
Indoor
units
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b)
20m
Total piping length (a+b)
30m
Bending point for each unit
20
Total bending point
30
a
Outdoor
unit
15m
It does not matter which unit is higher.
15m
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit Refrigerant piping length (one way, 2 unit total)
precharged
30m
20m
(g)
10m
b
1,300
200
0
Calculation : Xg = 20 g/m x (Refrigerant piping length(m) - 20)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
UNIT: mm (inch)
class
22/25/35
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Gas
9.52(3/8)
Outdoor unit union diameter
For
Liquid
6.35(1/4)
Indoor unit A
Gas
9.52(3/8)
Liquid
6.35(1/4)
Indoor unit B
Gas
9.52(3/8)
Extension pipe diameter
Liquid
Gas
6.35(1/4)
9.52(3/8)
88
MXZ-2A40VA -
E2
UNIT: mm
Compressor
R.V. coil
OFF
ON
Indoor unit
B
Refrigerant flow in cooling
Refrigerant flow in heating
Muffler
4-way valve
Stop valve
(with service port)
Outdoor heat
exchanger
temperature
thermistor
RT68
Stop valve
(with service port)
FAN-OUT
HEX-OUT
Indoor unit
A
Discharge
temperature
thermistor RT62
Ambient
temperature
thermistor
RT65
Capillary tube
Indoor unit
A
Stop valve
(with strainer #100)
Defrost
thermistor
RT61
LEV A
Strainer
#100
Capillary tube
Indoor unit
B
Stop valve
(with strainer #100)
LEV B
Indoor
units
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b)
20m
Total piping length (a+b)
30m
Bending point for each unit
20
Total bending point
30
a
Outdoor
unit
15m
15m
It does not matter which unit is higher.
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit Refrigerant piping length (one way, 2 unit total)
precharged
30m
20m
(g)
1,150
10m
b
200
0
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 20)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
class
22/25/35
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Gas
9.52(3/8)
UNIT: mm (inch)
Outdoor unit union diameter
For
Liquid
6.35(1/4)
Indoor unit A
Gas
9.52(3/8)
Liquid
6.35(1/4)
Indoor unit B
Gas
9.52(3/8)
Extension pipe diameter
Liquid
Gas
6.35(1/4)
9.52(3/8)
89
MXZ-3A54VA -
E1
,
E2
,
E3
,
UNIT: mm
E4
Compressor
R.V. coil
OFF
ON
Discharge
temperature
thermistor RT62
Refrigerant flow in cooling
Refrigerant flow in heating
Oil separator
Capillary tube
Ball valve with
service port
Indoor unit
C
Indoor unit
B
Indoor unit
A
4-way valve
Muffler
Outdoor heat
exchanger
temperature
thermistor
RT68
HEX-OUT
FAN-OUT
Ambient
temperature
thermistor
RT65
Defrost
thermistor
RT61
Capillary tube
Indoor unit
A
Indoor unit
B
Indoor unit
C
Capillary tube
Strainer
LEV A
#100
Capillary tube
Ball valve
Strainer
#100
Strainer
LEV B
#100
Capillary tube
Strainer
#100
Strainer
#100
LEV E
Distributor
Power
receiver
LEV C
MAX REFRIGERANT PIPING LENGTH
Indoor
units
Piping length each indoor unit (a, b, c)
25m
Total piping length (a+b+c)
50m
Bending point for each unit
25
Total bending point
50
a
b
Outdoor
unit
15m
It does not matter which unit is higher.
15m
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit Refrigerant piping length (one way, 3 unit total)
precharged
50m
40m
(g)
2,700
10m
c
200
0
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
class
22/25/35
50
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Outdoor unit union diameter
Extension pipe diameter
For
Liquid
6.35(1/4)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
12.7(1/2)
Gas
12.7(1/2)
Indoor unit A
Indoor unit B
Indoor unit C
90
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
MXZ-3A54VA -
E5
,
E6
,
UNIT: mm
E7
Compressor
R.V. coil
OFF
ON
Discharge
temperature
thermistor RT62
Refrigerant flow in cooling
Refrigerant flow in heating
Oil separator
Capillary tube
Indoor unit
C
Stop valve with
service port
Indoor unit
B
Indoor unit
A
4-way valve
Muffler
Outdoor heat
exchanger
temperature
thermistor
RT68
HEX-OUT
FAN-OUT
Ambient
temperature
thermistor
RT65
Defrost
thermistor
RT61
Capillary tube
Indoor unit
A
Indoor unit
B
Indoor unit
C
Capillary tube
Strainer
LEV A
#100
Capillary tube
Strainer Stop valve
#100
Strainer
LEV B
#100
Capillary tube
Strainer
#100
Strainer
#100
LEV E
Distributor
Power
receiver
LEV C
MAX REFRIGERANT PIPING LENGTH
Indoor
units
Piping length each indoor unit (a, b, c)
25m
Total piping length (a+b+c)
50m
Bending point for each unit
25
Total bending point
50
a
b
Outdoor
unit
15m
It does not matter which unit is higher.
15m
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit Refrigerant piping length (one way, 3 unit total)
precharged
50m
40m
(g)
2,700
10m
c
200
0
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
class
22/25/35/42
50
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Extension pipe diameter
Outdoor unit union diameter
For
Liquid
6.35(1/4)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
12.7(1/2)
Gas
12.7(1/2)
Indoor unit A
Indoor unit B
Indoor unit C
91
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
MXZ-4A71VA -
E1
,
E2
,
E3
,
UNIT: mm
E4
Compressor
R.V. coil
OFF
ON
Discharge
temperature
thermistor RT62
Refrigerant flow in cooling
Refrigerant flow in heating
Oil separator
Capillary tube
Indoor unit
D
Ball valve with
service port
4-way valve
Indoor unit
C
Indoor unit
B
Indoor unit
A
Muffler
Outdoor heat
exchanger
temperature
thermistor
RT68
HEX-OUT
FAN-OUT
Ambient
temperature
thermistor
RT65
Capillary tube
Indoor unit
A
Defrost
thermistor
RT61
Capillary tube
Indoor unit
B
Indoor unit
C
Indoor unit
D
Strainer
#100
LEV A
Strainer
#100
LEV B
Strainer
#100
LEV C
Strainer
#100
LEV D
Ball valve Strainer
#100
Strainer
#100
LEV E
Distributor
Power
receiver
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b, c, d)
25m
Total piping length (a+b+c+d)
60m
Bending point for each unit
25
Total bending point
60
Indoor
units
a
b
Outdoor
unit
15m
It does not matter which unit is higher.
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit
precharged
(g)
2,700
15m
c
Refrigerant piping length (one way, 4 unit total)
40m
0
50m
60m
200
400
10m
d
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
class
22/25/35
50
60
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Outdoor unit union diameter
Extension pipe diameter
For
Liquid
6.35(1/4)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
12.7(1/2)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
15.88(5/8)
Gas
15.88(5/8)
Indoor unit A
Indoor unit B
Indoor unit C
Indoor unit D
92
Liquid
6.35(1/4)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
MXZ-4A71VA -
E5
,
E6
,
UNIT: mm
E7
Compressor
R.V. coil
OFF
ON
Discharge
temperature
thermistor RT62
Refrigerant flow in cooling
Refrigerant flow in heating
Oil separator
Capillary tube
Indoor unit
D
Stop valve with
service port
Indoor unit
C
Indoor unit
B
Indoor unit
A
4-way valve
Muffler
Outdoor heat
exchanger
temperature
thermistor
RT68
HEX-OUT
FAN-OUT
Ambient
temperature
thermistor
RT65
Capillary tube
Indoor unit
A
Defrost
thermistor
RT61
Capillary tube
Indoor unit
B
Indoor unit
C
Indoor unit
D
Strainer
#100
LEV A
Strainer
#100
LEV B
Strainer
#100
LEV C
Strainer
#100
LEV D
Strainer
Stop valve
#100
Strainer
#100
LEV E
Distributor
Power
receiver
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b, c, d)
25m
Total piping length (a+b+c+d)
60m
Bending point for each unit
25
Total bending point
60
Indoor
units
a
b
Outdoor
unit
15m
It does not matter which unit is higher.
ADDITIONAL REFRIGERANT CHARGE
15m
c
Outdoor unit
precharged
(g)
Refrigerant piping length (one way, 4 unit total)
50m
40m
2,700
200
0
60m
400
10m
d
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
class
22/25/35/42
50
60
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Outdoor unit union diameter
Extension pipe diameter
Liquid
6.35(1/4)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
12.7(1/2)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
15.88(5/8)
Gas
15.88(5/8)
For
Indoor unit A
Indoor unit B
Indoor unit C
Indoor unit D
93
Liquid
6.35(1/4)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
MXZ-4A80VA -
UNIT: mm
E1
Compressor
R.V. coil
OFF
ON
Refrigerant flow in cooling
Refrigerant flow in heating
Discharge
temperature
thermistor RT62
High-pressure
switch
Oil separator
Capillary tube
Ball valve with
service port
Indoor unit
D
Indoor unit
C
4-way valve
Muffler
Indoor unit
B
Indoor unit
A
Outdoor
heat
exchanger
Ambient
temperature
thermistor
Outdoor heat RT65
exchanger
temperature
thermistor
RT68
Capillary tube
Indoor unit
A
Indoor unit
B
Indoor unit
C
Indoor unit
D
Defrost
thermistor
RT61
LEV A
Strainer
#100
Strainer
#100
LEV B
Strainer
#100
LEV C
Strainer
#100
LEV D
Capillary tube
Ball valve Strainer
#100
Strainer
#100
LEV E
Distributor
Power
receiver
Distributor
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b, c, d)
25m
Total piping length (a+b+c+d)
70m
Bending point for each unit
25
Total bending point
70
Indoor
units
a
b
Outdoor
unit
10m
It does not matter which unit is higher.
10m
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit
precharged
(g)
c
Refrigerant piping length (one way, 4 unit total)
40m
60m
50m
70m
10m
d
3,500
0
400
200
600
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
class
22/25/35
50
60
71
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Outdoor unit union diameter
Extension pipe diameter
Liquid
6.35(1/4)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
12.7(1/2)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
15.88(5/8)
Gas
15.88(5/8)
Liquid
9.52(3/8)
Liquid
9.52(3/8)
Gas
15.88(5/8)
Gas
15.88(5/8)
For
Indoor unit A
Indoor unit B
Indoor unit C
Indoor unit D
94
Liquid
6.35(1/4)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
MXZ-4A80VA R.V. coil
OFF
ON
UNIT: mm
E2
High-pressure Compressor
switch
Discharge
temperature
thermistor RT62
Oil separator
Refrigerant flow in cooling
Refrigerant flow in heating
Capillary tube
Indoor unit
D
Stop valve
(with service port)
Indoor unit
C
Indoor unit
B
Indoor unit
A
4-way valve
Muffler
Outdoor
heat
exchanger
Ambient
temperature
thermistor
Outdoor heat RT65
exchanger
temperature
thermistor
RT68
Capillary tube
Indoor unit
A
Indoor unit
B
Indoor unit
C
Indoor unit
D
Defrost
thermistor
RT61
LEV A
Strainer
#100
Strainer
#100
LEV B
Strainer
#100
LEV C
Strainer
#100
LEV D
Capillary tube
Stop valve Strainer
#100
Strainer
#100
LEV F
Distributor
Power
receiver
Indoor
units
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b, c, d)
25m
Total piping length (a+b+c+d)
70m
Bending point for each unit
25
Total bending point
70
a
b
Outdoor
unit
15m
It does not matter which unit is higher.
15m
ADDITIONAL REFRIGERANT CHARGE
c
Outdoor unit
precharged
(g)
40m
50m
60m
70m
3,500
0
200
400
600
Refrigerant piping length (one way, 4 unit total)
10m
d
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
class
22/25/35/42
50
60
71
Indoor unit
Pipe diameter
Liquid
6.35(1/4)
Extension pipe diameter
Liquid
6.35(1/4)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
12.7(1/2)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Gas
15.88(5/8)
Gas
15.88(5/8)
Liquid
9.52(3/8)
Liquid
9.52(3/8)
Gas
15.88(5/8)
Gas
15.88(5/8)
95
Outdoor unit union diameter
For
Indoor unit A
Indoor unit B
Indoor unit C
Indoor unit D
Liquid
6.35(1/4)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Gas
9.52(3/8)
UNIT: mm
MXZ-5A100VA
High-pressure
switch
R.V. coil
OFF
ON
Refrigerant flow in cooling
Refrigerant flow in heating
Compressor
Discharge
temperature
thermistor RT62
Oil separator
Capillary tube
Indoor unit
E
Stop valve
(with service port)
Indoor unit
D
Indoor unit
C
Indoor unit
B
4-way valve
Muffler
Indoor unit
A
Outdoor
heat
exchanger
Ambient
temperature
thermistor
Outdoor heat RT65
exchanger
temperature
thermistor
RT68
Capillary tube
Indoor unit
A
Indoor unit
B
Indoor unit
C
Indoor unit
D
Indoor unit
E
Defrost
thermistor
RT61
Strainer
#100
LEV A
Strainer
#100
LEV B
Strainer
#100
LEV C
Strainer
#100
LEV D
Strainer
#100
LEV E
Capillary tube
Stop valve Strainer
#100
Strainer
#100
LEV F
Distributor
Power
receiver
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b, c, d,e)
25m
Total piping length (a+b+c+d+e)
80m
Bending point for each unit
25
Total bending point
80
Indoor
units
a
b
Outdoor
unit
15m
It does not matter which unit is higher.
c
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit
precharged
(g)
4,000
15m
Refrigerant piping length (one way, 5 unit total)
40m
0
50m
200
60m
400
70m
600
80m
800
10m
d
e
Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40)
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 17-1.
UNIT: mm (inch)
Outdoor unit union diameter
Indoor unit
Extension pipe diameter
For
class
Pipe diameter
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Indoor unit A
22/25/35/42
Gas
12.7(1/2)
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Indoor unit B
50
Gas
9.52(3/8)
Gas
12.7(1/2)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
Indoor unit C
60
Gas
9.52(3/8)
Gas
15.88(5/8)
Gas
15.88(5/8)
Liquid
6.35(1/4)
Liquid
9.52(3/8)
Liquid
9.52(3/8)
Indoor unit D
71
Gas
9.52(3/8)
Gas
15.88(5/8)
Gas
15.88(5/8)
Liquid
6.35(1/4)
Indoor unit E
Gas
9.52(3/8)
96
10
PERFORMANCE CURVES
MXZ-2A30VA MXZ-3A54VA MXZ-5A100VA
MXZ-2A40VA MXZ-4A71VA
MXZ-2A52VA MXZ-4A80VA
The standard specifications apply only to the operation of the air conditioner under normal conditions.
Since operating conditions vary according to the areas where these units are installed, the following information has been provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198~264 V 50 Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
}
(1) Indoor intake air wet-bulb temperature :
°CWB
(2) Indoor outlet air wet-bulb temperature :
°CWB
Cooling
(3) Outdoor intake air dry-bulb temperature :
°CDB
(4) Total input:
W
(5) Indoor intake air dry-bulb temperature :
°CDB
Heating
(6) Outdoor intake air wet-bulb temperature :
°CWB
(7) Total input :
W
Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the
indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
}
How to measure the indoor air wet-bulb/dry-bulb temperature difference
1.
2.
3.
4.
5.
6.
7.
Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
Check that the air filter is cleaned.
Open windows and doors of room.
Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL
(HEAT) MODE.
When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
10 minutes later, measure temperature again and check that the temperature does not change.
INDOOR UNIT
OUTDOOR UNIT
Wet and dry-bulb
thermometers
FRONT VIEW
Wet-and dry-bulb
thermometers
BACK VIEW
97
9.3 10.6
7.8
8.5 9.7
7.1
7.8 8.8
6.4
7.0 7.9
5.8
6.3 7.1
5.1
5.6 6.3
25 class
25.4
24.0 25.9
23.4
22.2 23.9
21.5
20.3 21.9
19.5
18.5 19.9
17.6
16.6 17.9
12.9 13.9
11.7
11.1 12.0
r intak
e air W
et-bulb
tempe
rature
Indo
(°C)
Outdoor intake air Dry-bulb temperature (°C)
oor
Ind
35 class
14.8 15.9
25 class
15.6
13.7
22 class
Indoor air Dry-bulb temperature
Indoo
35 class
8.5
22 class
Indoor air Wet-bulb temperature
10-1. CAPACITY AND THE INPUT CURVES
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
ir
ea
)
(°C
ture
era
p
em
lb t
-bu
Dry
)
ture (°C
tempera
Outdoor intake air Dry-bulb temperature (°C)
take
or in
Indo
k
inta
et-bulb
e air W
or intak
Outdoor intake air Wet-bulb temperature (°C)
air
ulb
Dry-b
)
re (°C
eratu
temp
Outdoor intake air Wet-bulb temperature (°C)
9.5 13.1
13.7
7.8
8.5 9.7
8.7 11.9
12.4
7.1
7.8 8.8
8.0 10.8
11.3
6.4
7.0 7.9
7.2 9.7
10.1
5.8
6.3 7.1
6.5 8.7
9.0
5.1
5.6 6.3
5.7 7.7
8.0
22 class
25 class
42 class
60 class
50 class
9.3 10.6
35 class
8.5
25.4
24.0 25.9
27.0 31.4
31.9
23.4
22.2 23.9
24.9 29.0
29.4
21.5
20.3 21.9
22.8 26.6
27.0
19.5
18.5 19.9
20.7 24.1
24.5
17.6
16.6 17.9
18.7 21.7
22.1
11.7
11.1 12.0
12.4 14.5
14.7
60 class
17.2
50 class
19.6
14.5 16.9
42 class
16.6 19.3
12.9 13.9
35 class
14.8 15.9
25 class
15.6
13.7
22 class
Indoor air Dry-bulb temperature
Indoor air Wet-bulb temperature
MXZ-3A54VA
MXZ-4A71VA
Indoo
r intak
e air W
et-bulb
tempe
rature
Ind
(°C)
Outdoor intake air Dry-bulb temperature (°C)
oor
Ind
ir
ea
°C)
k
inta
Outdoor intake air Wet-bulb temperature (°C)
98
)
ture (°C
tempera
Outdoor intake air Dry-bulb temperature (°C)
b te
l
-bu
Dry
lb
Wet-bu
re (
atu
er
mp
ke air
oor inta
take
or in
Indo
air
ulb
Dry-b
re
eratu
temp
(°C)
Outdoor intake air Wet-bulb temperature (°C)
9.5 13.1
13.7 17.0
8.5 9.7
8.7 11.9
12.4 15.4
7.1
7.8 8.8
8.0 10.8
11.3 13.9
6.4
7.0 7.9
7.2
9.7
10.1 12.5
5.8
6.3 7.1
6.5
8.7
9.0 11.1
24.0 25.9
27.0 31.4
31.9 35.1
23.4
22.2 23.9
24.9 29.0
29.4 32.4
21.5
20.3 21.9
22.8 26.6
27.0 29.7
19.5
18.5 19.9
20.7 24.1
24.5 27.0
12.9 13.9
14.5 16.9
17.2 18.9
11.7
11.1 12.0
12.4 14.5
14.7 16.2
r intak
e air W
et-bulb
tempe
rature
(°C)
Outdoor intake air Dry-bulb temperature (°C)
ture
et-bulb
ke air W
ulb
ry-b
p
tem
Outdoor intake air Dry-bulb temperature (°C)
)
(°C
oor
ry-b
e air D
C)
ture (°
mpera
ulb te
k
r inta
Indoo
ir D
a
ake
)
ture (°C
tempera
inta
Indoor
era
int
Ind
71 class
13.7
60 class
19.6 21.6
50 class
22.1 24.3
16.6 19.3
42 class
18.7 21.7
14.8 15.9
35 class
16.6 17.9
25 class
17.6
15.6
Indoo
9.7
71 class
25 class
8.0
60 class
7.7
25.4
22 class
Indoor air Dry-bulb temperature
5.7
35 class
5.6 6.3
5.1
50 class
9.3 10.6
7.8
42 class
8.5
22 class
Indoor air Wet-bulb temperature
MXZ-4A80VA
Outdoor intake air Wet-bulb temperature (°C)
Outdoor intake air Wet-bulb temperature (°C)
7.8
12.4 15.4
7.1
7.8 8.8
8.0 10.8
11.3 13.9
6.4
7.0 7.9
7.2
9.7
10.1 12.5
5.8
6.3 7.1
6.5
8.7
9.0 11.1
5.1
5.6 6.3
5.7
7.7
8.0
24.0 25.9
27.0 31.4
31.9 35.1
23.4
22.2 23.9
24.9 29.0
29.4 32.4
21.5
20.3 21.9
22.8 26.6
27.0 29.7
19.5
18.5 19.9
20.7 24.1
24.5 27.0
17.6
16.6 17.9
18.7 21.7
22.1 24.3
11.1 12.0
12.4 14.5
14.7 16.2
71 class
11.7
60 class
17.2 18.9
50 class
19.6 21.6
14.5 16.9
42 class
16.6 19.3
12.9 13.9
35 class
14.8 15.9
25 class
15.6
13.7
Indoo
r intak
e air W
et-bulb
9.7
71 class
50 class
25.4
22 class
Indoor air Dry-bulb temperature
60 class
13.7 17.0
8.7 11.9
42 class
9.5 13.1
8.5 9.7
35 class
9.3 10.6
25 class
8.5
22 class
Indoor air Wet-bulb temperature
MXZ-5A100VA
tempe
rature
(°C)
Outdoor intake air Dry-bulb temperature (°C)
°C)
re (
atu
per
ea
tak
r in
oo
Ind
Outdoor intake air Wet-bulb temperature (°C)
99
)
ture (°C
tempera
Outdoor intake air Dry-bulb temperature (°C)
ture
pera
em
lb t
-bu
ry
ir D
Indoo
bulb
air Wetr intake
or
Indo
e air
intak
tem
-bulb
(°C)
Dry
Outdoor intake air Wet-bulb temperature (°C)
10-2. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
(OUTDOOR UNIT: MXZ-2A30VA/2A40VA - E2 )
1. 22-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
2. 25-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
(OUTDOOR UNIT: MXZ-2A40VA -
50
100
150 Hz
0
Frequency
Frequency
E2
50
100
150 Hz
Frequency
)
3. 35-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
Frequency
0
50
100
Frequency
100
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-2A40VA -
E1
, MXZ-2A52VA)
1. 22-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
2. 25-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
3. 35-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
Frequency
0
50
100
Frequency
101
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-3A54VA)
1. 22-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
2. 25-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
3. 35-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
150 Hz
0
Frequency
50
100
150 Hz
0
Frequency
50
100
150 Hz
Frequency
4. 42-class unit in single operation
<COOL>Capacity
1.5
<HEAT>Capacity
<COOL>Total input
1.5
<HEAT>Total input
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
150 Hz
0
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
5. 50-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
0
50
100
Frequency
Frequency
102
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-4A71VA)
1. 22-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
2. 25-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
3. 35-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
Frequency
0
50
100
Frequency
103
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-4A71VA)
4. 42-class unit in single operation
<COOL>Capacity
1.5
1.5
<COOL>Total input
1.5
<HEAT>Capacity
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
150 Hz
0
50
100
<HEAT>Total input
1.5
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
5. 50-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
6. 60-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
0
50
100
Frequency
Frequency
104
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-4A80VA)
1. 22-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
2. 25-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
3. 35-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
Frequency
0
50
100
Frequency
105
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-4A80VA)
4. 42-class unit in single operation
<COOL>Capacity
1.5
<COOL>Total input
1.5
<HEAT>Capacity
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.0
0
50
100
150 Hz
0.0
0
Frequency
50
100
150 Hz
0.0
0
50
100
<HEAT>Total input
1.5
150 Hz
0.0
0
Frequency
Frequency
50
100
150 Hz
Frequency
5. 50-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
6. 60-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
7. 71-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
0
50
100
Frequency
Frequency
106
150 Hz
0
50
100
Frequency
150 Hz
(OUTDOOR UNIT: MXZ-5A100VA)
1. 22-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
2. 25-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
3. 35-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
150 Hz
0
Frequency
50
100
150 Hz
0
Frequency
50
100
150 Hz
Frequency
4. 42-class unit in single operation
<COOL>Capacity
<COOL>Total input
<HEAT>Capacity
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
Frequency
150 Hz
107
0
50
100
Frequency
150 Hz
0
50
100
Frequency
150 Hz
5. 50-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
6. 60-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
150 Hz
0
Frequency
50
100
0
150 Hz
50
100
150 Hz
0
Frequency
Frequency
50
100
150 Hz
Frequency
7. 71-class unit in single operation
<COOL>Capacity
<HEAT>Capacity
<COOL>Total input
<HEAT>Total input
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0
50
100
Frequency
150 Hz
0
50
100
150 Hz
0
50
100
Frequency
Frequency
108
150 Hz
0
50
100
Frequency
150 Hz
10-3. TEST RUN OPERATION (How to operate fixed-frequency operation)
1. Press EMERGENCY OPERATION switch to COOL or HEAT mode (COOL : Press once, HEAT : Press twice).
2. Test run operation starts and continues to operate for 30 minutes.
3. Compressor operates at rated frequency.
4. Indoor fan operates at High speed.
5. After 30 minutes, test run operation finishes and EMERGENCY OPERATION starts (Operation frequency of compressor
varies).
6. To cancel test run operation (EMERGENCY OPERATION), press EMERGENCY OPERATION switch or any button on
remote controller.
10-4. OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT (single operation)
NOTE: The unit of pressure has been changed to MPa on the international system of units (SI unit system).
The conversion factor is : 1 (MPa[Gauge]) = 10.2(kgf/cm2 [Gauge])
(1) COOL operation
Dry-bulb temperature ( )
Relative humidity (%)
20
50
25
60
30
70
Both indoor and outdoor unit are under the
same temperature/humidity condition.
Operation : TEST RUN OPERATION (Refer to 10-3.)
MXZ-2A30VA MXZ-2A40VA 22-class unit
E2
25-class unit
(MPa[Gauge])
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
42Hz
20
50
25
60
30
70
3
42Hz
2
1
15
35
(%)
Ambient temperature ( )
Ambient humidity (%)
MXZ-2A40VA-
20
50
25
60
30
70
35
(%)
E2
13
1.3
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
4
Outdoor unit current (A)
Outdoor low pressure
(MPa[Gauge])
1.4
42Hz
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
3
42Hz
2
1
15
35
(%)
20
50
25
60
30
70
1.4
13
1.3
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
4
42Hz
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
Ambient temperature ( )
Ambient humidity (%)
35-class unit
14
14
Outdoor unit current (A)
13
1.3
Outdoor low pressure
4
1.4
Outdoor unit current (A)
Outdoor low pressure
(MPa[Gauge])
14
35
(%)
Ambient temperature ( )
Ambient humidity (%)
109
3
42Hz
2
1
15
35
(%)
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
35
(%)
MXZ-2A40VA -
MXZ-2A52VA
E1
22-class unit
25-class unit
(MPa[Gauge])
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
30Hz
0.7
15
20
50
30Hz
2
1
15
35
30
70
25
60
3
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
1.4
13
1.3
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
35
30
70
25
60
14
4
Outdoor unit current (A)
13
1.3
4
Outdoor low pressure
1.4
Outdoor unit current (A)
Outdoor low pressure
(MPa[Gauge])
14
30Hz
20
50
(%)
30
70
25
60
3
30Hz
2
1
15
35
Ambient temperature ( )
Ambient humidity (%)
Ambient temperature ( )
Ambient humidity (%)
20
50
(%)
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
35-class unit
4
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
30Hz
20
30
70
25
3
30Hz
2
1
15
35
20
Ambient temperature ( )
Ambient humidity (%)
35
30
70
25
(%)
(%)
Ambient temperature ( )
Ambient humidity (%)
MXZ-3A54VA MXZ-4A71VA
22-class unit
11
1.1
1.0
9
0.9
8
0.8
7
0.7
6
0.6
15
20
50
25
60
30
70
12
4
40Hz
3
2
1
15
35
Outdoor low pressure
40Hz
10
25-class unit
5
Outdoor unit current (A)
Outdoor low pressure
12
(MPa[Gauge])
1.2
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
25
60
30
70
10
1.0
9
0.9
8
0.8
7
0.7
15
20
50
1.0
9
0.9
8
0.8
7
0.7
6
0.6
15
20
50
30
70
25
60
4
40Hz
3
2
1
15
35
(%)
Ambient temperature ( )
Ambient humidity (%)
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
4
40Hz
3
2
1
15
35
(%)
Outdoor low pressure
1.1
10
(%)
5
Outdoor unit current (A)
Outdoor low pressure
11
1.1
20
50
30
70
25
60
35
(%)
Ambient temperature ( )
Ambient humidity (%)
42-class unit
40Hz
1.2
11
Ambient temperature ( )
Ambient humidity (%)
(MPa[Gauge])
1.3
12
5
40Hz
35
35-class unit
13
(MPa[Gauge])
1.2
Outdoor unit current (A)
13
1.3
20
50
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
13
(MPa[Gauge])
1.3
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
20
40Hz
25
Outdoor unit current (A)
1.4
Outdoor unit current (A)
Outdoor low pressure
(MPa[Gauge])
14
30
110
4
40Hz
3
2
1
15
35
(%)
Ambient temperature ( )
Ambient humidity (%)
5
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
35
(%)
MXZ-3A54VA MXZ-4A71VA
MXZ-4A71VA
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
20
50
25
60
30
70
4
40Hz
3
2
1
15
35
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
25
60
30
70
0.9
8
0.8
7
0.7
6
0.6
15
20
50
30
70
25
60
3
2
(%)
1.0
9
0.9
8
0.8
7
0.7
15
20
50
20
50
30
70
25
60
30
70
25
60
24Hz
3
2
(%)
20
50
30
70
25
60
35
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
20
50
1.1
1.0
9
0.9
8
0.8
7
0.7
6
0.6
15
35
30
70
25
60
(%)
Ambient temperature ( )
Ambient humidity (%)
5
20
50
13
(MPa[Gauge])
1.3
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
4
24Hz
3
2
1
15
35
30
70
25
60
20
50
(%)
35
30
70
25
60
(%)
Ambient temperature ( )
Ambient humidity (%)
24Hz
20
50
(%)
25
60
30
70
35
Ambient temperature ( )
Ambient humidity (%)
5
4
24Hz
3
2
1
15
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
60-class unit
5
24Hz
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
4
24Hz
3
2
1
15
35
(%)
Outdoor low pressure
1.2
11
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
4
1
15
35
Outdoor unit current (A)
Outdoor low pressure
12
11
10
(%)
50-class unit
(MPa[Gauge])
1.3
2
1
15
35
30
70
25
60
3
(MPa[Gauge])
1.2
35
5
Ambient temperature ( )
Ambient humidity (%)
13
20
50
24Hz
Outdoor low pressure
10
0.8
15
40Hz
42-class unit
Outdoor unit current (A)
Outdoor low pressure
1.1
8
Ambient temperature ( )
Ambient humidity (%)
24Hz
1.2
0.9
12
24Hz
1
15
35
(MPa[Gauge])
1.3
11
9
4
Ambient temperature ( )
Ambient humidity (%)
35-class unit
12
1.0
(%)
4
Ambient temperature ( )
Ambient humidity (%)
13
1.1
Outdoor low pressure
9
11
10
5
Outdoor unit current (A)
Outdoor low pressure
10
1.0
1.2
25-class unit
24Hz
1.1
12
5
40Hz
Ambient temperature ( )
Ambient humidity (%)
(MPa[Gauge])
1.2
11
1.3
35
MXZ-4A80VA
22-class unit
12
13
Outdoor unit current (A)
11
(MPa[Gauge])
1.4
Outdoor unit current (A)
1.2
14
Outdoor unit current (A)
12
5
40Hz
20
50
25
60
30
70
35
(%)
14
(MPa[Gauge])
1.4
13
1.3
12
1.2
5
Outdoor unit current (A)
(MPa[Gauge])
1.3
Outdoor low pressure
13
60-class unit
Outdoor unit current (A)
Outdoor low pressure
50-class unit
24Hz
11
1.1
10
1.0
9
0.9
8
0.8
15
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
Ambient temperature ( )
Ambient humidity (%)
111
4
24Hz
3
2
1
15
35
(%)
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
35
(%)
MXZ-5A100VA
22-class unit
71-class unit
(MPa[Gauge])
1.4
1.3
11
1.1
10
1.0
9
0.9
8
0.8
15
20
50
30
70
25
60
24Hz
3
2
1
15
35
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
0.9
8
0.8
7
0.7
6
0.6
15
20
50
30
70
25
60
4
24Hz
3
2
1
15
35
20
50
(%)
Ambient temperature ( )
Ambient humidity (%)
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
20
50
24Hz
25
60
30
70
4
24Hz
3
2
20
50
(%)
25
60
30
70
1.1
10
1.0
9
0.9
8
0.8
15
20
50
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
20
50
13
(MPa[Gauge])
1.3
12
1.2
11
1.1
10
1.0
9
0.9
8
0.8
7
0.7
15
35
(%)
20
50
(%)
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
5
25
60
30
70
4
24Hz
3
2
1
15
35
20
50
(%)
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
20
50
5
24Hz
30
70
25
60
4
24Hz
3
2
1
15
35
(%)
Ambient temperature ( )
Ambient humidity (%)
14
(MPa[Gauge])
1.4
13
1.3
12
1.2
5
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
4
24Hz
3
2
1
15
35
(%)
Outdoor low pressure
11
1
15
35
20
50
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
71-class unit
Outdoor unit current (A)
Outdoor low pressure
1.2
12
Ambient temperature ( )
Ambient humidity (%)
24Hz
12
2
Ambient temperature ( )
Ambient humidity (%)
5
1
15
35
(MPa[Gauge])
1.4
1.3
30
70
25
60
(MPa[Gauge])
1.3
(%)
60-class unit
13
20
50
3
50-class unit
Ambient temperature ( )
Ambient humidity (%)
14
0.6
15
24Hz
Outdoor low pressure
12
6
Ambient temperature ( )
Ambient humidity (%)
Outdoor unit current (A)
Outdoor low pressure
13
0.7
35
30
70
25
60
42-class unit
(MPa[Gauge])
1.3
0.8
7
13
Outdoor low pressure
Outdoor unit current (A)
Outdoor low pressure
9
8
24Hz
Ambient temperature ( )
Ambient humidity (%)
5
1.1
1.0
0.9
4
35-class unit
(MPa[Gauge])
1.2
10
9
Ambient temperature ( )
Ambient humidity (%)
24Hz
11
1.0
(%)
MXZ-5A100VA
25-class unit
12
10
35
30
70
25
60
1.1
Outdoor unit current (A)
1.2
11
Outdoor unit current (A)
12
4
20
50
25
60
30
70
35
(%)
Ambient temperature ( )
Ambient humidity (%)
5
Outdoor unit current (A)
13
5
24Hz
Outdoor low pressure
24Hz
(MPa[Gauge])
1.2
12
5
Outdoor unit current (A)
Outdoor low pressure
14
Outdoor unit current (A)
MXZ-4A80VA
24Hz
11
1.1
10
1.0
9
0.9
8
0.8
15
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
112
4
24Hz
3
2
1
15
35
(%)
20
50
25
60
30
70
Ambient temperature ( )
Ambient humidity (%)
35
(%)
HEAT operation
Condition :
Indoor
Outdoor
Dry bulb temperature (°C)
20.0
2
7
15
20.0
Wet bulb temperature (°C)
14.5
1
6
12
14.5
Operation : TEST RUN OPERATION (Refer to 10-3.)
MXZ-2A30VA MXZ-2A40VA22-class unit
Outdoor unit current (A)
2
48Hz
3
2
1
1
10
15
20
MXZ-2A40VA-
10
15
20
25
5
Ambient temperature ( )
Outdoor unit current (A)
35Hz
3
2
1
35Hz
3
2
20
25
5
7
2
10
15
20
5
25
48Hz
5
4
3
2
6
48Hz
5
4
3
25
Ambient temperature ( )
42-class unit
7
48Hz
5
4
3
10
15
20
25
5
10
15
20
25
MXZ-4A71VA
60-class unit
7
Outdoor unit current (A)
5
48Hz
4
3
6
5
48Hz
4
3
2
2
5
10
15
20
5
25
10
15
20
Ambient temperature ( )
Ambient temperature ( )
113
48Hz
5
4
3
0
5
10
15
20
25
Ambient temperature ( )
Ambient temperature ( )
6
6
2
2
5
7
Outdoor unit current (A)
25
6
Ambient temperature ( )
MXZ-3A54VA MXZ-4A71VA
50-class unit
20
7
2
20
15
35-class unit
Outdoor unit current (A)
6
10
Ambient temperature ( )
7
Outdoor unit current (A)
Outdoor unit current (A)
35Hz
3
Ambient temperature ( )
MXZ-3A54VA MXZ-4A71VA
22-class unit
25-class unit
15
25
1
1
10
20
4
Ambient temperature ( )
5
15
35-class unit
25-class unit
4
15
10
Ambient temperature ( )
MXZ-2A52VA
E1
4
10
2
1
5
25
22-class unit
5
48Hz
3
Outdoor unit current (A)
5
Ambient temperature ( )
Outdoor unit current (A)
Outdoor unit current (A)
48Hz
4
Outdoor unit current (A)
4
3
E2
35-class unit
25-class unit
4
Outdoor unit current (A)
MXZ-2A40VA-
E2
25
7
32Hz
5
4
3
2
6
32Hz
5
4
3
2
5
10
15
20
25
20
6
5
32Hz
4
3
15
20
5
32Hz
4
3
10
15
20
4
3
2
50-class unit
5
4
3
10
15
20
4
3
5
10
15
20
Ambient temperature ( )
25
15
20
25
25
42-class unit
7
32Hz
5
4
3
10
15
20
25
7
5
32Hz
4
3
6
5
32Hz
4
3
2
5
10
15
20
25
5
Ambient temperature ( )
10
15
20
Ambient temperature ( )
114
32Hz
5
4
3
0
5
10
15
20
25
Ambient temperature ( )
71-class unit
6
6
2
5
Ambient temperature ( )
2
2
10
6
25
Outdoor unit current (A)
Outdoor unit current (A)
32Hz
20
3
2
5
7
5
15
32Hz
7
60-class unit
6
10
4
Ambient temperature ( )
7
5
Ambient temperature ( )
35-class unit
32Hz
Ambient temperature ( )
0
5
5
6
25
25
Ambient temperature ( )
2
20
20
6
25
Outdoor unit current (A)
Outdoor unit current (A)
5
15
2
5
7
32Hz
3
7
25-class unit
6
4
2
10
32Hz
5
71-class unit
Ambient temperature ( )
7
15
3
6
Ambient temperature ( )
2
25
MXZ-5A100VA
22-class unit
10
4
5
6
Ambient temperature ( )
5
5
25
Outdoor unit current (A)
Outdoor unit current (A)
Outdoor unit current (A)
15
7
2
Outdoor unit current (A)
10
60-class unit
7
10
32Hz
Ambient temperature ( )
50-class unit
5
6
2
5
Ambient temperature ( )
7
Outdoor unit current (A)
6
42-class unit
7
Outdoor unit current (A)
Outdoor unit current (A)
Outdoor unit current (A)
7
Outdoor unit current (A)
35-class unit
25-class unit
Outdoor unit current (A)
MXZ-4A80VA
22-class unit
25
11
ACTUATOR CONTROL
MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA
MXZ-5A100VA
Relation between main sensor and actuator
Sensor
Purpose
Discharge temperature thermistor
Protection
Indoor coil thermistor
Defrosting Protection
Defrost thermistor
Gas pipe temperature thermistor
(MXZ-3A54VA- E1 , E2 , E3
MXZ-4A71VA- E1 , E2 , E3
MXZ-4A80VA- E1 )
Defrosting
Fin temperature thermistor
Protection
Ambient temperature thermistor
Outdoor heat exchanger temperature
Capacity code
Compressor
Control
Control
Protection
Control
115
Actuator
Outdoor
Reversing
LEV
fan motor
valve
12
SERVICE FUNCTIONS
MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA
MXZ-5A100VA
12-1. LOCKING THE OPERATION MODE OF THE CONDITIONER (COOL, DRY, HEAT)
Description of the function:
With this function, you can lock the operation mode of the
outdoor unit. Once the operation mode is locked to either
COOL/DRY mode or HEAT mode, the air conditioner
operates in that mode only.
Initial setting is required to activate this function. Please
explain about this function to your customers and ask
them whether they want to use it.
ON
MXZ-2A30/2A40/2A52
[How to lock the operation mode]
COOL/DRY
Turn OFF the power supply for the air conditioner
before making the setting.
Set SW1 on the display P.C. board or the outdoor
electronic control P.C. board as shown in the right figure.
Turn ON the power supply for the air conditioner.
MXZ-3A54/4A71VA
MXZ-4A80VA- E1
HEAT
SW1
SW1
ON
ON
MXZ-2A30/2A40/2A52/3A54/4A71VA
MXZ-4A80VA- E1
COOL/DRY
HEAT
SW1
SW2
SW1
SW1
ON
SW871
ON
MXZ-4A80VA- E2
MXZ-5A100VA
12-2. LOWERING THE OPERATING NOISE OF THE OUTDOOR UNIT
MXZ-4A80VA- E2
MXZ-5A100VA
Description of the function:
With this function, you can lower the operating noise of the outdoor unit when the operation load is small,
for example, during nighttime in COOL mode. However, please note that the cooling and heating capacity
can also be lowered if this function is activated.
Initial setting is required to activate this function. Please explain about this function to your customers and
ask them whether they want to use it.
[How to lower the operating noise]
Turn OFF the power supply for the air conditioner before making the setting.
Set the 3rd Dip Switch of SW1 on the display P.C. board or the outdoor electronic
control P.C. board to ON to enable this function.
Turn ON the power supply for the air conditioner.
12-3. PRE-HEAT CONTROL <MXZ-2A, MXZ-3A54VA- E4 ,
MXZ-4A80VA- E2 , MXZ-5A100VA>
E5
,
E6
,
E7
SW1
ON
, MXZ-4A71VA-
E4
,
E5
,
E6
,
E7
,
If moisture gets into the refrigerant cycle, or when refrigerant is liquefied and collected in the compressor, it may interfere
the start-up of the compressor.
To improve start-up condition, the compressor is energized even while it is not operating.
This is to generate heat at the winding.
The compressor uses about 50 W when pre-heat control is turned ON.
Pre-heat control is ON at initial setting.
[How to deactivate pre-heat control]
Turn OFF the power supply for the air conditioner before making the setting.
Set the 4th Dip Switch of SW2 on the outdoor electronic control P.C. board to ON
to deactivate pre-heat control function (MXZ-4A80VA- E2 , MXZ-5A100VA).
Set the 4th Dip Switch of SW1 on the outdoor electronic control P.C. board to ON to
deactivate pre-heat control function (MXZ-3A54VA- E4 , E5 , E6 , E7 , MXZ-4A71VA- E4 , E5 , E6 , E7 ).
Cut the JK wire of the inverter P.C. board to deactivate pre-heat control
SW2
function (MXZ-2A).
ON
SW2
1 2 3 4 5 6
SW1
ON
JK
ON
JK
1 2 3 4 5 6
MXZ-4A80VA- E2
MXZ-5A100VA
1 2 3 4
MXZ-3A54VA- E4 , E5 , E6
MXZ-4A71VA- E4 , E5 , E6
, E7
, E7
SW1
SW2
SW871
MXZ-2A
Turn ON the power supply for the air conditioner.
NOTE: Pre-heat control will be turned OFF when the breaker is turned OFF.
116
MXZ-4A80VA- E2
MXZ-5A100VA
12-4. AUTO LINE CORRECTING
Outdoor unit has an auto line correcting function which automatically detects and corrects improper wiring or piping.
<MXZ-2A>
Improper wiring or piping can be automatically detected when one indoor unit is operated in COOL mode for 30 minutes.
When improper wiring or piping is detected, wiring lines are corrected (A to B/ B to A) with the software.
NOTE:
This function may not work due to the condition or environment of the unit, such as the following:
- gas leak, closed stop valve
- unit failure such as defective LEV
- indoor/outdoor temperature
<Correct line>
Refrigerant piping
Indoor/outdoor
connecting wire
A
B
INDOOR UNIT A
A
B
INDOOR UNIT B
OUTDOOR UNIT
<Incorrect wiring>
A
B
INDOOR UNIT A
A
B
INDOOR UNIT B
OUTDOOR UNIT
<Incorrect piping>
A
B
INDOOR UNIT A
A
B
OUTDOOR UNIT
INDOOR UNIT B
117
The record of auto line correcting can be confirmed in the following way:
Turn OFF the power supply.
Turn ON the 4th Dip Switch of SW1 on the display P.C. board.
Turn ON the power supply.
Confirm the correction by the blinking of LED.
Number of blinks
LED1 (Red) LED2 (Yellow)
Once
Once
3 times
3 times
SW1
ON
Wiring line
MXZ-2A
Not corrected
Corrected
Turn OFF the power supply after the confirmation, and turn OFF the 4th Dip Switch of SW1 on the display P.C. board.
Turn ON the power supply.
NOTE: This function does not work when the jumper wire JGO on the inverter P.C. board is cut.
<MXZ-4A80VA-
E2
, MXZ-5A100VA>
Improper wiring or piping can be automatically detected by pressing the piping/wiring correction switch (SW871).
When improper wiring or piping is detected, wiring lines are corrected.
This will be completed in about 10 to 15 min.
[How to activate this function]
1. Check that outside temperature is above 0°C .
(This function does not work when outside temperature is not above 0°C.)
2. Check that the stop valves of the liquid pipe and gas pipe are open.
SW871
3. Check that the wiring between indoor and outdoor unit is correct.
(If the wiring is not correct, this function does not work.)
4. Turn ON the power supply and wait at least 1 minute.
5. Press the piping/wiring correction switch (SW871) on the electronic control P.C. board.
Do not touch energized parts.
SW871
LED indication during detection:
LED1(Red) LED2(Yellow) LED3(Green)
Lighting
Lighting
Blinking
LED indication after detection:
LED1(Red) LED2(Yellow) LED3(Green)
Indication
Lighting
Goes out
Lighting
Completed (Detected successfully)
Blinking
Blinking
Blinking
Cannot be corrected
Refer to"SAFETY PRECAUTIONS WHEN LED FLASHES" located behind the service panel.
Other indications
Be sure to check for closed valves, cracked pipes or clogged pipes.
6. Press the switch to cancel.
LED indication after cancel:
LED1(Red) LED2(Yellow) LED3(Green)
Lighting
Lighting
Goes Out
NOTE: Indoor unit cannot be operated while this function is activated.
When this function is activated while indoor unit is operating, the operation will be stopped.
Operate indoor unit after the auto line correcting is finished.
Pressing the switch during detection cancels this function.
118
The record of auto line correcting can be confirmed in the following way:
Press the switch for more than 5 sec.
LED will show the record of auto correcting for about 30 sec. as shown in the table below:
LED1(Red)
Once
3 times
Number of blinks
Wiring line
LED2(Yellow) LED3(Green)
Once
Lighting
Not corrected
3 times
Lighting
Corrected
NOTE: Activate this function to confirm the correct wiring after replacing the electronic control P.C. board.
(Previous records are deleted when the electronic control P.C. board is replaced.)
The record cannot be shown if auto line correcting is not canceled (Refer to "How to activate this function").
12-5. INCREASING MAXIMUM COMPRESSOR OPERATIONAL FREQUENCY AND FAN SPEED OF THE
OUTDOOR UNIT
<MXZ-4A80VA- E2 , MXZ-5A100VA>
Compressor operational frequency and fan speed can be increased.
Capacity of the unit can be improved with this function.
NOTE:
Compressor operational frequency may not be increased under primary current restriction or high pressure protection.
Compressor operational frequency will not be increased when 1 or 2 indoor units are operating.
This function doesn't work when the function which lowers the operating noise of the outdoor unit is activated.
Noise level of the outdoor unit will increase (You may need to explain this to your customers.)
[How to increase maximum compressor operational frequency and fan speed]
Turn OFF the power supply for the air conditioner before making the setting.
Set the 3rd Dip Switch of SW2 on the outdoor electronic control P.C. board to ON to enable this function.
Turn ON the power supply for the air conditioner.
SW2
ON
1 2 3 4 5 6
12-6. CHANGING DEFROST FINISH TEMPERATURE AND HEAT OPERATION TIME
<MXZ-4A80VA- E2 , MXZ-5A100VA>
If defrosting operation starts more than necessary, the defrost finish temperature and heat operation time can be changed.
The number of defrosting operation and defrosting time can be reduced with this function.
Defrost finish temperature (°C)
Heat operation time (min.)
Initial setting
10
31
Changed
5
40
[How to change defrost finish temperature and heat operation time]
Turn OFF the power supply for the air conditioner before making the setting.
Set the 1st Dip Switch of SW2 on the outdoor electronic control P.C. board to ON to enable this function.
Turn ON the power supply for the air conditioner.
SW2
ON
1 2 3 4 5 6
12-7. CHANGING THE AMPERE LIMIT
<MXZ-4A80VA- E2 , MXZ-5A100VA>
With this function, you can change the current that flows in the
outdoor unit.
NOTE:
Use this function only when the amount of current exceeds
the allowed value.
SW 2
MXZ-4A80VA - E2
MXZ-5A100VA
ON
10.5A
ON
[How to change the ampere limit]
Be sure to turn OFF the power supply for the air conditioner
before making the setting.
Make the setting referring to the table on the right.
Turn ON the power supply for the air conditioner.
119
15.5A
ON
Initial setting
Full
13
TROUBLESHOOTING
MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA
MXZ-5A100VA
13-1. CAUTIONS ON TROUBLESHOOTING
1. Before troubleshooting, check the following:
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for miswiring.
2. Take care of the following during servicing
1) Before servicing the air conditioner, be sure to turn OFF the unit first with the remote controller, and after confirming
the horizontal vane is closed, turn OFF the breaker and/or disconnect the power plug.
2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic
control P.C. board.
3) When removing the electrical parts, be careful of the residual voltage of smoothing capacitor.
4) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the
components.
5) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
Lead wiring
Housing point
3. Troubleshooting procedure
1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality.
To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2) If the electronic control P.C. board seems to be defective, check the copper foil pattern for disconnection and the components for bursting and discoloration.
3) Refer to 13-2, 13-3 and 13-4.
13-2. FAILURE MODE RECALL FUNCTION
This air conditioner can memorize the abnormal condition which has occurred once.
Even though LED indication listed on the troubleshooting check table (13-4) disappears, the memorized failure details
can be recalled.
This mode is very useful when the unit needs to be repaired for the abnormality which doesn’t recur.
1. Type of failure mode recall function
There are 2 types in failure mode recall function as shown below.
Indoor and outdoor unit failure mode recall function
With this function, failure mode of indoor unit and a part of failure mode of outdoor unit can be recalled.
The details of outdoor unit failure mode recall function
With this function, more detailed failure mode of outdoor unit can be recalled.
Refer to the service manual of indoor unit for how to recall the failure mode and the details of indoor unit failure mode.
The outdoor unit failure mode is indicated by the operation indicator lamp on the indoor unit and the LED of outdoor unit.
See "13-2.2. Outdoor unit failure mode table".
120
2. Outdoor unit failure mode table
MXZ-2A
Upper or left lamp of
OPERATION INDICATOR
lamp (Indoor unit)
Abnormal point
(Failure mode / protection)
LED indication
Condition
(Outdoor P.C. board)
LED 1 LED 2
Lighting Lighting
Lighting Lighting Overcurrent protection stop is
continuously performed three times
within 1 minute after the compressor
gets started.
OFF
2-time flash
None (Normal)
Outdoor power system
3-time flash
Discharge temperature
thermistor
Lighting Once
Defrost thermistor
Ambient temperature thermistor
Fin temperature thermistor
P.C. board temperature
thermistor
Lighting
Lighting
Lighting
Lighting
Outdoor heat exchanger
temperature thermistor
Lighting 9 times
4-time flash
Thermistor shorts or opens during
compressor running.
Once
Twice
3 times
4 times
• Refer to 13-6. "Check
of outdoor thermistors".
• Refer to 13-6. "Check
of outdoor thermistors".
Once Goes out 23 A (MXZ-2A30VA- E1 , MXZ-2A40VA,
MXZ-2A52VA)/ 14 A (MXZ-2A30VA- E2 )
current flows into intelligent power
module.
Compressor
Twice
9 times Goes
out
• Check the connection
of the compressor
connecting wire.
• Refer to 13-6.
"How to check
inverter/compressor".
• Check the stop valve.
• Replace the outdoor
electronic control
P.C. board.
Overcurrent
Goes
out
Correspondence
The possibility of intercepting the
overcurrent by the compressor lock is
high.
The compressor doesn't synchronize
with the operating power.
• Reconnect compressor
connector.
• Refer to 13-6. "How
to check inverter/
compressor".
• Check the stop valve.
• Check the connection of
the compressor
connecting wire.
• Refer to 13-6. "How to
check inverter/
compressor".
5-time flash
Discharge temperature
Lighting Lighting Discharge temperature exceeds 116°C • Check refrigerant circuit
during operation.
and refrigerant amount.
Compressor can restart if discharge
• Refer to 13-6. "Check
temperature thermistor reads 100°C or of LEV".
less 3 minutes later.
6-time flash
High pressure
Lighting Lighting The outdoor heat exchanger
temperature exceeds 70°C during
cooling or the indoor gas pipe
temperature exceeds 70°C during
heating.
• Check refrigerant circuit
and refrigerant amount.
• Check the stop valve.
7-time flash
Fin temperature
3 times
Goes
out
The fin temperature exceeds 90°C
during operation.
P.C. board temperature
4 times
Goes
out
The P.C. board temperature exceeds
78°C during operation.
• Check around outdoor
unit.
• Check outdoor unit air
passage.
• Refer to 13-6. "Check
of outdoor fan motor".
8-time flash
Outdoor fan motor
Lighting Lighting Failure occurs continuously three
times within 30 seconds after
the fan gets started.
9-time flash
Nonvolatile memory data
Lighting 5 times Nonvolatile memory data cannot be
read properly.
10-time flash
Discharge temperature
• Refer to 13-6. "Check
of outdoor fan motor".
• Replace the outdoor
electronic control
P.C. board.
Lighting Lighting The frequency of the compressor is
• Check refrigerant circuit
kept 68 Hz (MXZ-2A30VA, MXZand refrigerant amount.
2A40VA- E2 )/ 80Hz (MXZ-2A40VA- E1 , • Refer to 13-6. "Check
MXZ-2A52VA) or more and the
of LEV".
discharge temperature is kept under
50°C (COOL mode)/40°C (HEAT mode)
for more than 40 minutes.
NOTE: Blinking patterns of this mode differ from the ones of Troubleshooting check table (13-4).
121
Indoor/outdoor
unit failure mode
recall function
Upper or left lamp of
OPERATION INDICATOR
lamp (Indoor unit)
11-time flash
14-time flash
15-time flash
Abnormal point
(Failure mode / protection)
LED indication
(Outdoor P.C. board)
LED 1 LED 2
Condition
Correspondence
Current sensor
8 times
Goes
out
A short or open circuit is detected in
the current sensor
during compressor operating.
• Replace the power
board.
Bus-bar voltage
6 times Goes
out
The bus-bar voltage exceeds 430 V
or falls to 50 V or below during
compressor operating.
• Replace the power
board.
Power module
7 times Goes
out
There is a high possibility that the
power module is out of order.
• Refer to 13-6. "How to
check inverter/
compressor".
Stop valve
(Closed valve)
Lighting 12 times Closed valve is detected by compressor • Check the stop valve.
current.
(MXZ-2A30VA, MXZ-2A40VA - E2 )
LEV for drain
Lighting Lighting
The indoor unit detects any
abnormalities in the LEV for drain.
• Refer to 13-6. "Check
of LEV".
• Check the drain pump of
the indoor unit.
NOTE: Blinking patterns of this mode differ from the ones of Troubleshooting check table (13-4).
122
Indoor/outdoor
unit failure mode
recall function
MXZ-3A/4A/5A
Upper or left lamp of
OPERATION INDICATOR
lamp (Indoor unit)
Abnormal point
(Failure mode / protection)
LED indication
Condition
(Outdoor P.C. board)
LED 1 LED 2
Lighting Lighting
Lighting Lighting Overcurrent protection stop is
continuously performed three times
within 1 minute after the compressor
gets started, or converter protection
stop or bus-bar voltage protection
stop is continuously performed
three times within 3 minutes after
start-up.
OFF
2-time flash
None (Normal)
Outdoor power system
3-time flash
Discharge temperature
thermistor
Lighting Once
Defrost thermistor
Ambient temperature thermistor
Fin temperature thermistor
P.C. board temperature
thermistor
Lighting
Lighting
Lighting
Lighting
Outdoor heat exchanger
temperature thermistor
Lighting 9 times
Gas pipe temperature
thermistor A
Gas pipe temperature
thermistor B
Gas pipe temperature
thermistor C
Gas pipe temperature
thermistor D
Lighting 10 times A short or open circuit is detected in
the thermistor during cooling.
Lighting 11 times (A,B,C : MXZ-3A54VA- E1 , E2 , E3
MXZ-4A71VA- E1 , E2 , E3
MXZ-4A80VA- E1 )
Lighting 12 times
(D
: MXZ-4A71VA- E1 , E2 , E3
MXZ-4A80VA- E1 )
Lighting 13 times
Thermistor shorts or opens during
compressor running.
Once
Twice
3 times
4 times
Correspondence
• Check the connection
of the compressor
connecting wire.
• Refer to 13-6.
"How to check
inverter/compressor".
• Check the stop valve.
• Refer to 13-6. "Check
of outdoor thermistors".
• Replace the outdoor
electronic control
P.C. board.
• Refer to 13-6. "Check
of outdoor thermistors".
4-time flash
Overcurrent
5-time flash
Discharge temperature
Lighting Lighting Discharge temperature exceeds 116°C • Check refrigerant circuit
during operation.
and refrigerant amount.
Compressor can restart if discharge
• Refer to 13-6. "Check
temperature thermistor reads 100°C or of LEV".
less 3 minutes later.
6-time flash
High pressure
Lighting Lighting High-pressure is detected with the
high-pressure switch (HPS)
during operation.
(MXZ-4A80VA, MXZ-5A100VA)
The outdoor heat exchanger
temperature exceeds 70°C during
cooling or the indoor gas pipe
temperature exceeds 70°C during
heating.
3 times Goes The fin temperature exceeds 89°C
out
during operation.
7-time flash
Fin temperature
Once Goes out 28A current flows into intelligent power • Reconnect compressor
module.
connector.
• Refer to 13-6. "How to
check inverter/
compressor".
• Check the stop valve.
P.C. board temperature
4 times
8-time flash
Outdoor fan motor
Lighting Lighting Failure occurs continuously three
times within 30 seconds after the
fan gets started.
9-time flash
Nonvolatile memory data
Lighting 5 times Nonvolatile memory data cannot be
read properly.
10-time flash
Discharge temperature
Goes
out
The P.C. board temperature exceeds
73°C (MXZ-3A54VA, MXZ-4A71VA)/
87°C (MXZ-4A80VA, MXZ-5A100VA)
during operation.
• Check refrigerant circuit
and refrigerant amount.
• Check the stop valve.
• Check around outdoor
unit.
• Check outdoor unit air
passage.
• Refer to 13-6. "Check
of outdoor fan motor".
• Refer to 13-6. "Check
of outdoor fan motor".
• Replace the outdoor
electronic control
P.C. board.
Lighting Lighting The frequency of the compressor is
• Check refrigerant circuit
and refrigerant amount.
kept 80Hz or more and the discharge
• Refer to 13-6. "Check
temperature is kept under
50°C (COOL mode)/40°C (HEAT mode) of LEV".
for more than 40 minutes.
NOTE: Blinking patterns of this mode differ from the ones of Troubleshooting check table (13-4).
123
Indoor/outdoor
unit failure mode
recall function
Upper or left lamp of
OPERATION INDICATOR
lamp (Indoor unit)
11-time flash
LED indication
(Outdoor P.C. board)
LED 1 LED 2
Abnormal point
(Failure mode / protection)
Correspondence
Condition
Communication error
between P.C. boards
Lighting 6 times
Communication error occurs
between the electronic control P.C.
board and power board for more
than 10 seconds.
The communication between boards
protection stop is continuously
performed twice.
Current sensor
Lighting 7 times
Zero cross detecting circuit
5 times
A short or open circuit is detected in
the current sensor during compressor
operating.
Current sensor protection stop is
continuously performed twice.
Zero cross signal cannot be detected
while the compressor is operating.
Goes
out
The protection stop of the zero cross
detecting circuit is continuously
performed 10 times.
15-time flash
Indoor/outdoor
unit failure mode
recall function
• Check the connecting
wire between outdoor
electronic control
P.C. board and power
board.
• Replace the power
board.
• Check the connecting
wire among electronic
control P.C. board,
noise filter P.C. board
and power board.
• Check the voltage of
power supply.
• Replace the power board.
Converter
5 times Goes
out
A failure is detected in the operation
of the converter during operation.
Bus-bar voltage
(1)
5 times
Goes
out
The bus-bar voltage exceeds 400 V or
falls to 200 V or below during
compressor operating.
Bus-bar voltage
(2)
Even if this protection stop is
performed continuously three
times, it does not mean the
abnormality in outdoor power
system.
6 times Goes
out
The bus-bar voltage exceeds
400 V (MXZ-3A54VA, MXZ-4A71VA)/
430 V (MXZ-4A80VA, MXZ-5A100VA)
or falls to 50V or below during
compressor operating.
• Check the voltage of
power supply.
• Replace the outdoor
electronic control
P.C. board.
LEV for drain
Lighting Lighting
The indoor unit detects any
abnormalities in the LEV for drain.
• Refer to 13-6. "Check
of LEV".
• Check the drain pump of
the indoor unit.
NOTE: Blinking patterns of this mode differ from the ones of "Troubleshooting check table" (13-4).
13-3. INSTRUCTION OF TROUBLESHOOTING
• Check the indoor unit with referring to the indoor unit service manual, and confirm whether there is any problem in the indoor
unit.
Then, check the outdoor unit with referring to this page.
Operation start
Check the outdoor unit
LED indicator.
Both LED 1
and LED 2
are OFF.
LED 1 or LED 2
has blinked.
Both LED 1 and
LED 2 are lighting.
Refer to 13-4.
"Troubleshooting check table".
Refer to 13-6.
"Check of power supply".
• Indoor unit
serial signal
error
Refer to 13-6.
"How to
check
miswiring and
serial signal
error".
• COOL or
HEAT
operation only
Refer to 13-6.
"Check of
R.V. coil".
• When cooling, heat
exchanger of
non-operating indoor
unit frosts.
•When heating, nonoperating indoor unit
gets warm.
Refer to 13-6.
"Check of LEV".
• When cooling,
dew drops in the
non-operating
indoor unit.
Check of
mispiping
124
• When heating,
room does not get
warm.
Refer to 13-6.
"How to check of
inverter/compressor".
Check mispiping,
shortage of capacity
• When cooling,
room does not
cool.
Refer to 13-6.
"How to check
of inverter/
compressor".
13-4. TROUBLESHOOTING CHECK TABLE
MXZ-2A
No. Symptom
Outdoor unit
1 does not
operate.
Indication
LED1(Red) LED2(Yellow)
Lighting
Once
Abnormal point / Condition
LEV for drain
2
Lighting
Twice
Outdoor power system
3
Lighting
3 times
Discharge temperature
thermistor
4
Lighting
5
Lighting
4 times
5 times
Fin temperature
thermistor
P.C board temperature
thermistor
Ambient temperature
thermistor
Condition
The indoor unit detects any abnormality in the LEV for drain.
Overcurrent protection stop is continuously performed three times
within 1 minute after the compressor gets started.
Correspondence
• Refer to 13-6 "Check of LEV".
• Check the drain pump of the indoor unit.
• Check the connection of the compressor connecting
wire.
• Refer to 13-6. "How to check inverter/compressor".
• Check the stop valve.
A short circuit is detected in the thermistor during operation, or when an
open circuit is detected in the thermistor after 10 minutes of compressor • Refer to 13-6. "Check of outdoor thermistors".
start-up.
• Refer to 13-6. "Check of outdoor thermistors".
A short or open circuit is detected in the thermistor during operation.
• Replace the outdoor electronic control P.C. board.
A short or open circuit is detected in the thermistor during operation.
Outdoor heat exchanger
temperature thermistor
A short circuit is detected in the thermistor during operation, or when
an open circuit is detected in the thermistor after 5 minutes (in cooling)
and 10 minutes (in heating) of compressor start-up.
Defrost thermistor
A short circuit is detected in the thermistor during operation, or when an
open circuit is detected in the thermistor after 5 minutes of compressor
start-up.
• Refer to 13-6. "Check of outdoor thermistors".
6
Lighting
7 times
Nonvolatile memory data
The nonvolatile memory data cannot be read properly.
• Replace the outdoor electronic control P.C. board.
7
Lighting
11 times
Stop valve
Closed valve
Closed valve is detected by compressor current.
(MXZ-2A30VA, MXZ-2A40VA - E2 )
• Check the stop valve.
Overcurrent
Twice
Goes out
23 A (MXZ-2A30VA- E1 , MXZ-2A40VA, MXZ-2A52VA)/ 14 A (MXZ-2A
30VA- E2 )current flows into intelligent power module.
3 times
Goes out
Discharge temperature
protection
Discharge temperature exceeds 116°C during operation. Compressor can • Check the amount of gas and refrigerant circuit.
restart if discharge temperature thermistor reads 100°C or less 3 minutes • Refer to 13-6. "Check of LEV".
later.
4 times
Goes out
Fin temperature
protection
P.C. board temperature
protection
8
'Outdoor
unit stops
and restarts
3 minutes
later' is
repeated.
9
10
11
5 times
Goes out
High-pressure
protection
12
9 times
Goes out
Bus-bar voltage
protection
13
13 times
Goes out
Outdoor fan motor
14
8 times
Goes out
Current sensor
protection
15
10 times
Goes out
Compressor
Once
Lighting
16
Outdoor unit
operates.
Primary current protection
The fin temperature exceeds 90°C during operation.
Twice
Lighting
The outdoor heat exchanger temperature exceeds 70°C during cooling
or indoor gas pipe temperature exceeds 70°C during heating.
• Check the amount of gas and the refrigerant circuit.
• Check the stop valve.
The bus-bar voltage exceeds 430 V or falls to 50 V or below during
compressor operating.
Failure occurs continuously three times within 30 seconds after the fan
gets started.
A short or open circuit is detected in the current sensor during
compressor operating.
• Replace the power board.
• Refer to 13-6.
The compressor doesn't synchronize
with the operating power.
• Reconnect compressor connector.
• Refer to 13-6. "How to check inverter/compressor".
• Check the stop valve.
The input current exceeds 8 A (MXZ-2A30VA)/ 10 A (MXZ-2A40VA,
MXZ-2A52VA).
High-pressure protection
The indoor gas pipe temperature exceeds 45°C during heating.
Defrosting in cooling
The indoor gas pipe temperature falls 3°C or below during cooling.
The discharge temperature exceeds 100°C during operation.
18
3 times
Lighting
Discharge temperature
protection
19
4 times
Lighting
Low discharge
temperature protection
• Check refrigerant circuit and refrigerant amount.
• Refer to 13-6. "Check of outdoor fan motor".
The P.C. board temperature exceeds 78°C during operation.
Secondary current protection The current of the compressor exceeds 17 A.
17
• Reconnect compressor connector.
• Refer to 13-6. "How to check inverter/compressor".
• Check the stop valve.
"Check of outdoor fan motor".
• Replace the power board.
These symptoms do not mean any abnormality of the
product, but check the following points.
• Check if indoor filters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air circulation is short cycled.
• Check refrigerant circuit and refrigerant amount.
• Refer to 13-6. "Check of LEV".
• Refer to 13-6. "Check of outdoor thermistors".
The frequency of the compressor is kept 80 Hz or more and the discharge
• Refer to 13-6. "Check of LEV".
temperature is kept under 50°C (COOL mode)/40°C (HEAT mode) for
• Check refrigerant circuit and refrigerant amount.
more than 40 minutes.
125
No. Symptom
Indication
Abnormal point / Condition
LED1(Red) LED2(Yellow)
Outdoor unit
operates.
20
5 times
Lighting
Cooling high-pressure
protection
Outdoor unit
21 operates
normally.
9 times
Lighting
Inverter check mode
22
Lighting
Lighting
Normal
Condition
Correspondence
This symptom does not mean any abnormality of the
product, but check the following points.
The outdoor heat exchanger temperature exceeds 58°C during operation. • Check if indoor filters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air circulation is short cycled.
The unit is operated with emergency operation switch.
-
-
-
Display P.C. board(Parts side)
NOTE 1. The location of LED is illustrated at the right figure. Refer to 13-7.6.
2. LED is lighted during normal operation.
The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the flashing frequency is “2”.
0.5-second ON
ON
OFF
2.5-second OFF
2.5-second OFF
126
LED1 LED2
Lighting
0.5-second ON
MXZ-3A/4A/5A
No. Symptom
Outdoor unit
does not
operate.
Indication
LED1(Red) LED2(Yellow)
Abnormal point / Condition
Condition
Correspondence
Lighting
Once
LEV for drain
• Refer to 13-6. "Check of LEV".
The indoor unit detects any abnormality in the LEV for drain.
• Check the drain pump of the indoor unit.
2
Lighting
Twice
Outdoor power system
• Check the connection of the compressor connecting
Overcurrent protection stop is continuously performed three times
within 1 minute after the compressor gets started, or converter protection wire.
• Refer to 13-6. "How to check inverter/compressor".
stop or bus-bar voltage protection stop is continuously performed three
• Check the stop valve.
times within 3 minutes after start-up.
3
Lighting
3 times
Discharge temperature
thermistor
4
Lighting
4 times
1
5
Lighting
Fin temperature
thermistor
P.C board temperature
thermistor
Ambient temperature
thermistor
• Replace the outdoor electronic control P.C. board.
Current sensor protection stop is continuously performed twice.
• Replace the power board.
8 times
Current sensor
Gas pipe temperature
thermistor A
Gas pipe temperature
thermistor B
Gas pipe temperature
thermistor C
Gas pipe temperature
thermistor D
10
Lighting
12 times
Twice
Goes out
11
'Outdoor unit
stops and
restarts 3
minutes
later' is
repeated.
12
3 times
Goes out
13
4 times
Goes out
14
5 times
Goes out
15
8 times
Goes out
16
17
18
Overcurrent is detected after 30 minutes of compressor start-up.
Lock protection
Overcurrent is detected within 30 minutes of compressor start-up
Discharge temperature
protection
Discharge temperature exceeds 116°C during operation. Compressor can • Check the amount of gas and refrigerant circuit.
restart if discharge temperature thermistor reads 100°C or less 3 minutes • Refer to 13-6. "Check of LEV".
later.
Fin temperature
protection
P.C. board temperature
protection
High-pressure
protection
Lighting
12 times
•Check refrigerant circuit and refrigerant amount.
•Refer to 13-6. "Check of outdoor fan motor".
The P.C. board temperature exceeds 73°C (MXZ-3A54VA, MXZ-4A71VA)/
87°C (MXZ-4A80VA, MXZ-5A100VA) during operation.
High-pressure is detected with the high-pressure switch (HPS) during
• Check the amount of gas and the refrigerant circuit.
operation. (MXZ-4A80VA, MXZ-5A100VA)
• Check the stop valve.
A failure is detected in the operation of the converter during operation.
• Replace the power board.
Bus-bar voltage
protection (1)
The bus-bar voltage exceeds 400 V or falls to 200 V or below during
compressor operating.
The bus-bar voltage exceeds 400 V (MXZ-3A54VA, MXZ-4A71VA)/
430 V (MXZ-4A80VA, MXZ-5A100VA) or falls to 50 V or below during
compressor operating.
• Check the voltage of power supply.
• Replace the power board or the outdoor electronic
control P.C. board.
• Refer to 13-6. “Check of bus-bar voltage”.
Outdoor fan motor
20
The fin temperature exceeds 89°C during operation.
Converter protection
Goes out
11 times
• Reconnect compressor connector.
• Refer to 13-6. "How to check inverter/compressor".
• Check the stop valve.
• Check the power module (PAM module).
The outdoor heat exchanger temperature exceeds 70°C during cooling
or indoor gas pipe temperature exceeds 70°C during heating.
13 times
Lighting
• Refer to 13-6. "Check of outdoor thermistors".
IPM protection
Bus-bar voltage
protection (2)
19
"Check of outdoor thermistors".
Communication error occurs twice between the outdoor electronic control • Check the connecting wire between outdoor electronic control
P.C. board and power board for more than 10 seconds.
P.C. board and power board.
• Check the connecting wire among outdoor electronic control
The protection stop of the zero cross detecting circuit is continuously
P.C. board, noise filter P.C. board and power board.
performed 10 times.
Goes out
8 times
A short or open circuit is detected in the thermistor during cooling.
(A,B,C : MXZ-3A54VA- E1 , E2 , E3 , MXZ-4A71VA- E1 , E2 , E3
MXZ-4A80VA- E1 )
(D
: MXZ-4A71VA- E1 , E2 , E3 , MXZ-4A80VA- E1 )
• Refer to 13-6.
Communication error
between P.C. boards
Zero cross detecting
circuit
9 times
Lighting
A short or open circuit is detected in the thermistor during operation.
The nonvolatile memory data cannot be read properly.
Lighting
11 times
• Replace the outdoor electronic control P.C. board.
Nonvolatile memory data
7
Lighting
"Check of outdoor thermistors".
A short circuit is detected in the thermistor during operation, or an open
circuit is detected in the thermistor after 5 minutes of compressor start-up.
7 times
9
• Refer to 13-6.
A short or open circuit is detected in the thermistor during operation.
Defrost thermistor
Lighting
10 times
"Check of outdoor thermistors".
A short circuit is detected in the thermistor during operation, or an open
circuit is detected in the thermistor after 5 minutes (in cooling) and 10
minutes (in heating) of compressor start-up.
6
Lighting
• Refer to 13-6.
Outdoor heat exchanger
temperature thermistor
5 times
8
A short circuit is detected in the thermistor during operation, or an open
circuit is detected in the thermistor after 10 minutes of compressor start-up.
Current sensor
protection
Failure occurs continuously three times within 30 seconds after the fan
gets started.
A short or open circuit is detected in the current sensor during compressor
operating.
Communication error occurs between the outdoor electronic control P.C.
board and power board for more than 10 seconds.
Communication protection
between P.C. boards
Zero cross detecting circuit
Zero cross signal cannot be detected while the compressor is operating.
protection
127
• Refer to 13-6.
"Check of outdoor fan motor".
• Replace the power board.
• Check the connecting wire between outdoor electronic
control P.C. board and power board.
• Check the connecting wire among outdoor electronic
control P.C. board, noise filter P.C. board and power board.
No. Symptom
Indication
LED1(Red) LED2(Yellow)
Outdoor unit
operates.
21
Twice
Lighting
The input current exceeds 15 A (MXZ-3A54VA, MXZ-4A71VA)/
17 A (MXZ-4A80VA)/18 A (MXZ-5A100VA).
High-pressure protection
Defrosting in cooling
The indoor gas pipe temperature falls 3°C or below during cooling.
Lighting
Secondary current protection
22
Correspondence
These symptoms do not mean any abnormality of the
product, but check the following points.
The current of the compressor exceeds 12 A (MXZ-3A54VA, MXZ-4A71VA)/ • Check if indoor filters are clogged.
• Check if refrigerant is short.
10 A (MXZ-4A80VA, MXZ-5A100VA).
• Check if indoor/outdoor unit air circulation is short cycled.
The indoor gas pipe temperature exceeds 45°C during heating.
Primary current protection
Once
Condition
Abnormal point / Condition
• Check refrigerant circuit and refrigerant amount.
• Refer to 13-6. "Check of LEV".
• Refer to 13-6. "Check of outdoor thermistors".
23
3 times
Lighting
Discharge temperature
protection
The discharge temperature exceeds 100°C during operation.
24
4 times
Lighting
Low discharge
temperature protection
The frequency of the compressor is kept 80 Hz or more and the discharge
• Refer to 13-6. "Check of LEV".
temperature is kept under 50°C (COOL mode) /40°C (HEAT mode) for
• Check refrigerant circuit and refrigerant amount.
more than 40 minutes.
5 times
Lighting
Cooling high-pressure
protection
This symptom does not mean any abnormality of the
product, but check the following points.
The outdoor heat exchanger temperature exceeds 58°C during operation. • Check if indoor filters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air circulation is short cycled.
9 times
Lighting
Inverter check mode
The unit is operated with emergency operation switch.
Lighting
Lighting
Normal
25
26
Outdoor unit
operates
normally.
27
-
-
-
NOTE 1. The location of LED is illustrated at the right figure. Refer to 13-7.2.
2. LED is lighted during normal operation.
Outdoor electronic control P.C. board(Parts side)
MXZ-3A54VA, MXZ-4A71VA, MXZ-4A80VA- E1
The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the flashing frequency is “2”.
LED2 LED1
Lighting
0.5-second ON
0.5-second ON
MXZ-4A80VA-
E2 , MXZ-5A100VA
LED1 LED2
ON
OFF
2.5-second OFF
2.5-second OFF
Lighting
128
13-5. TROUBLE CRITERION OF MAIN PARTS
MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA
MXZ-5A100VA
Part name
Defrost thermistor (RT61)
Check method and criterion
Fin temperature thermistor (RT64)
Measure the resistance with a tester.
Ambient temperature
thermistor (RT65)
Refer to 13-7. “Test point diagram and voltage”, 1. “Inverter P.C. board” , 2. “Outdoor
electronic control P.C. board” or 5. “Outdoor Power board”, for the chart of thermistor.
Outdoor heat exchanger temperature
thermistor (RT68)
Gas pipe temperature thermistor
(RT6A~D)
MXZ-3A54VA- E1 , E2 , E3
MXZ-4A71VA- E1 , E2 , E3
MXZ-4A80VA- E1
Measure the resistance with a tester.
Before measurement, hold the thermistor with your hands to warm it up.
Discharge temperature
thermistor (RT62)
Refer to 13-7. “Test point diagram and voltage”, 1. “Inverter P.C. board” or 2. “Outdoor
electronic control P.C. board”, for the chart of thermistor.
Compressor
W
Measure the resistance between terminals using a tester.
(Winding temperature : -10°C ~ 40°C)
RED
V
WHT
2A30VA
2A40VA-
U
BLK
1.49
Outdoor fan motor
WHT
2
RED
WHT
BLK
U
MXZ-2A
0.56
~ 0.69
0.39
~ 0.49
3A54VA 4A71VA -
0.86
, ,
, ,
,
,
4A80VA
5A100VA
E4 E5 E6 E7
E4 E5 E6 E7
~ 1.06
1.29
Normal (Each phase)
U (W)
1
W
V
~ 1.84
Normal (Each phase)
3A54VA - E1 , E2 , E3
E1
4A71VA - E1 , E2 , E3
Measure the resistance between lead wires using a tester.
(Part temperature : -10°C ~ 40°C)
RED BLK
3
E2
2A40VA2A52VA
V (V)
W (U)
MXZ-3A/4A/5A
MXZ-2A
12
13.4
~ 16
~ 16.4
MXZ-3A/4A/5A
Measure the resistance using a tester. (Part temperature : -10°C ~ 40°C)
Normal (Each phase)
R.V. coil
MXZ-3A54VA MXZ-4A71VA -
E4
E4
, E5 , E6 , E7
, E5 , E6 , E7
1.2 k ~ 1.56 k
1.26 k ~ 1.62 k
Linear expansion valve
WHT
RED
LEV
ORN
Other models
Measure the resistance using a tester. (Part temperature : -10°C ~ 40°C)
Normal
Color of lead wire
WHT - RED
RED - ORN
YLW - BRN
BRN - BLU
37.4
~ 53.9
YLW BRN BLU
High pressure switch (HPS)
MXZ-4A80/5A100
Pressure
3.7 0.15 MPa
0.05
4.8 +
MPa
- 0.1
HPS
129
Normal
Close
Open
~ 1.49
13-6. TROUBLESHOOTING FLOW
Outdoor unit does not operate.
Check of power supply
MXZ-2A30/2A40/2A52
Check the connecting of parts of main power supply circuit.
Turn ON the power supply.
Is there voltage of 230V AC in the
power supply terminal block?
No
Check the power supply cable.
Yes
Is the output voltage from the power
P.C. board 230V AC?
No
Is fuse (F61 or F64)
blown?
No
Replace the power
P.C. board.
Yes
Yes
Is the input voltage to the inverter P.C.
board 230V AC?
Replace the fuse.
No
Replace the reactor.
Yes
Replace the inverter P.C. board.
MXZ-3A54/4A71/4A80/5A100
Check the connecting of parts of main power supply circuit.
Turn ON the power supply.
Is there voltage of 230V AC in the
power supply terminal block?
No
Check the power supply cable.
Yes
Is the output voltage from the noise
filter P.C. board 230V AC?
No
Is fuse (F64) blown?
No
Yes
Yes
Is the input voltage to the power board
230V AC?
Replace the fuse.
No
Replace the reactor.
Yes
No
Is the input voltage to the outdoor
electronic control P.C. board 325V DC?
Replace the power board.
Yes
Replace the outdoor electronic control
P.C. board.
130
Replace the noise
filter P.C. board.
• When unit cannot operate neither by the remote controller nor by EMERGENCY OPERATION switch.
Indoor unit does not operate.
• When OPERATION INDICATOR lamp flashes ON and OFF in every 0.5-second.
Outdoor unit does not operate.
How to check mis-wiring and serial signal error (when outdoor unit does not work)
LED indication
for communication status
Communication status is indicated
by the LED.
Turn OFF the power supply.
Unit status
Blinking: normal communication
Lighting: abnormal communication or
not connected
Pattern 1 and 2 is repeatedly displayed
alternately. Each pattern is displayed for
15 seconds.
NOTE: "Lighting" in the table below does not
indicate abnormal communication.
Is there rated voltage in
the power supply?
Check the power
supply.
Yes
Turn ON the power supply.
Is there rated voltage between
outdoor terminal block S1 and
S2?
MXZ-2A52VA
No
Check the wiring.
Yes
Outdoor display P.C. board
Press EMERGENCY OPERATION switch once.
LED1 LED2
Does the left lamp of OPERATION
INDICATOR lamp light up?
<Confirmation of the power to the indoor unit>
Blinking
LED 1
Unit A
status
No
LED 2
Unit B
status
No
Yes
Is serial signal error indicated 6 minutes later?
MXZ-3A54VA
MXZ-4A71VA
MXZ-4A80VA - E1
No
Yes
Is there any miswiring,
poor contact, or wire
disconnection of the
indoor/outdoor
connecting wire?
Yes
Correct them.
No
Outdoor electronic control P.C. board
(Parts side)
A
LED3 LED2 LED1
Blinking
Pattern
LED 3
1
Lighting
2
Goes out
LED 2
LED 1
Unit B
status
Unit D
status
Unit A
status
Unit C
status
Turn OFF the power supply.
Check once more if the indoor/outdoor
B connecting wire is not miswiring.
Short-circuit outdoor terminal block S2 and
S3.
1
1. Miswiring may damage indoor electronic control
P.C. board during the operation.
Be sure to confirm the wiring is correct before the
operation starts.
Turn ON the power supply.
MXZ-4A80VA - E2
MXZ-5A100VA
Outdoor electronic control P.C. board
(Parts side)
Does the LED on the outdoor display P.C.
board or the outdoor electronic
control P.C. board repeat "3.6-second-OFF
and 0.8-second-ON quick blinking"?
LED1 LED2 LED3
No
(Lighted
or
not lighted)
Blinking
Yes
Pattern
LED 1
LED 2
LED 3
1
Unit A
status
Unit D
status
Unit B
status
Unit E
status
Unit C
status
2
Goes out
A
· Turn OFF inverter-controlled lighting
equipment.
· Turn OFF the power supply and
turn ON again.
· Press EMERGENCY OPERATION
switch.
Is serial signal
error indicated
6 minutes later?
Yes
B
· Reinstall
either the
unit or the
light away
from each
No other.
· Attach a filter
on remote
control
receiving
section of
the indoor
unit.
Turn OFF the power supply.
Remove the short-circuit between
outdoor terminal block S2 and S3.
Turn ON the power supply.
Is there amplitude of 10 to 20V DC
between outdoor terminal block S2
and S3? <Confirmation of serial
signal>
No
Replace the inverter P.C. board or
the outdoor electronic control P.C. board.
2
2 Be careful of residual
voltage of smoothing capacitor.
Is there any error of the
indoor/outdoor connecting wire,
such as the damage of the wire,
intermediate connection, poor
contact to the terminal block?
Yes
Replace the
indoor/outdoor
connecting wire.
Yes
Replace the
indoor/outdoor
connecting wire.
No
Yes
Is there rated voltage between
indoor terminal block S1 and S2?
<Confirmation of power voltage>
No
Is there any error of the
indoor/outdoor connecting wire,
such as the damage of the wire,
intermediate connection, poor
contact to the terminal block?
Yes
No
Replace the indoor electronic control P.C. board.
Be sure to release the failure-mode
recall function after checking.
Refer to indoor unit service manual.
131
The cooling operation or heating operation does not operate.
Check of R.V. coil
MXZ-2A
CN912 Power P.C. board
CN781
MXZ-3A/4A/5A
Noise filter P.C. board
Outdoor electronic control
P.C. board
CN933 Inverter P.C. board
• When heating operation does not work.
1. Disconnect the lead wire leading to the compressor.
2. 3 minutes after turning ON the power supply, start EMERGENCY
OPERATION in HEAT mode.
Is there voltage of 230V AC between pin1 and
pin 2 at connector CN912?
1. Turn OFF the power supply of indoor and outdoor unit, and
disconnect the connector CN933 or CN781.
2. 3 minutes after turning ON the power supply, start
EMERGENCY OPERATION in HEAT mode.
No
Yes
Turn OFF the power supply of indoor and outdoor unit.
Disconnect the connector
CN912. Is there normal
resistance to R.V. coil?
(Refer to 13-5.)
No
Is there voltage 12V DC
between the connector CN933
No
pin 1 (+) and pin 3 (-) or the
connector CN781
pin 5 (+) and pin 3 (-) ?
Replace the R.V. coil.
Yes
Replace the inverter P.C.
board or the electronic
control P.C. board.
Yes
Replace the power P.C. board or
the noise filter P.C. board.
Replace the 4-way valve.
• When cooling operation does not work.
1. Disconnect the lead wire leading to the compressor.
2. 3 minutes after turning ON the power supply, start EMERGENCY
OPERATION in COOL mode.
Is there voltage of 230V AC between pin1 and
pin 2 at connector CN912?
Yes
No
Replace the 4-way valve.
If the connector CN912 is not connected or R.V. coil is open, voltage
occurs between terminals even when the control is OFF.
1. Turn OFF the power supply of the indoor and the outdoor
unit, and disconnect the connector CN933 or CN781.
2. 3 minutes after turning ON the power supply, start
EMERGENCY OPERATION in COOL mode.
Is there voltage 12V DC
between the connector CN933
pin 1 (+) and pin 3 (-) or the
connector CN781
pin 5 (+) and pin 3 (-) ?
No
Replace the power P.C.board or
the noise filter P.C. board.
Yes
Replace the inverter P.C. board or the outdoor electronic control P.C. board.
132
• When cooling, heat exchanger of non-operating indoor unit frosts.
• When heating, non-operating indoor unit gets warm.
Check of LEV
Turn ON the power supply to the outdoor unit after checking LEV coil is mounted
to the LEV body securely.
Yes
Is "click - click" sound heard?
Or, do you feel vibration of LEV coil with your hand?
Normal
No
Disconnect the connectors.
CN791: LEV A, CN792: LEV B, CN793: LEV C,
CN794: LEV D, CN795: LEV E, CN796: LEV F.
Is there normal resistance to LEV coil?
(Refer to 13-5.)
No
Yes
Replace the inverter P.C. board or
the outdoor electronic control P.C. board.
Replace LEV coil.
133
• When heating, room does not get warm.
• When cooling, room does not get cool.
How to check inverter/ compressor
Disconnect the terminal of the compressor. 3 minutes after turning ON the power supply, start
EMERGENCY OPERATION.
Measure the voltage between each
lead wire leading to the compressor.
U (BLK) - V (WHT)
V (WHT) - W (RED)
W (RED) - U (BLK)
Output voltage
COOL: 150V (48Hz) HEAT: 170V (64Hz)
Is voltage output? 1, 2
1 After the outdoor fan starts running, wait for 1 minute
or more before measuring the voltage.
The output voltage values have the tolerance of ± 20%.
2 The output differs depending on the capacity or the
number of indoor units to be operated.
No
Yes
(MXZ-2A) Yes
Is output balanced?
No
Yes (MXZ-3A/4A/5A)
Is the input voltage to the outdoor electronic
control P.C. board 370V or more?
No
Replace the inverter P.C. board or
the power board.
Yes
Turn OFF the power supply of indoor and outdoor
unit, and measure the compressor winding
resistance between the compressor terminals.
Is there resistance between each terminal normal?
(Refer to 13-5.)
Yes
No
Reconnect the lead wire of compressor, and turn ON
the power supply to indoor and outdoor unit.
3 minutes later, start EMERGENCY OPERATION.
Clarify the causes by counting time until the inverter stops.
0 to 10 seconds: compressor layer short
10 to 60 seconds: compressor lock
60 seconds to 5minutes: refrigerant circuit defective
5 minutes or more: normal
134
Replace the
compressor.
• When thermistor is abnormal.
Check of outdoor thermistors
Disconnect the connector in the following table and measure
the resistance of the thermistor to check whether the thermistor
is normal or not. (Refer to 13-7.)
Abnormal
Replace the thermistor except RT64.
In case that RT64 is abnormal,
replace the inverter P.C. board or
the outdoor power board since RT64
is combined with the inverter P.C.
board or the outdoor power board.
Normal
Reconnect the connector in the following table and
disconnect the lead wire leading to the compressor.
3 minutes after turning ON the power supply,
start EMERGENCY OPERATION.
Does the unit operate 10 minutes or more without
showing thermistor abnormality?
No
Yes
Replace the inverter P.C. board,
the outdoor electronic control P.C. board,
or the outdoor power board.
Normal
MXZ-2A30/2A40/2A52
Thermistor
Defrost
Discharge temperature
Outdoor heat exchanger temperature
Fin temperature
Ambient temperature
Symbol
RT61
RT62
RT68
RT64
RT65
Connector, Pin No.
Between CN661 pin1 and pin2
Between CN661 pin3 and pin4
Between CN661 pin5 and pin6
Between CN662 pin1 and pin2
Between CN663 pin1 and pin2
Board
Inverter P.C. board
MXZ-3A54/4A71/4A80/5A100
Board
Connector, Pin No.
Thermistor
Symbol
RT61 Between CN661 pin1 and pin2
Defrost
RT62 Between CN661 pin3 and pin4
Discharge temperature
RT68 Between CN661 pin7 and pin8
Outdoor heat exchanger temperature
RT6A Between CN662 pin1 and pin2
Gas pipe temperature (Unit A)
Outdoor electronic control P.C. board
RT6B Between CN662 pin3 and pin4
Gas pipe temperature (Unit B)
RT6C Between CN662 pin5 and pin6
Gas pipe temperature (Unit C)
RT6D Between CN662 pin7 and pin8
Gas pipe temperature (Unit D)
RT65 Between CN663 pin1 and pin2
Ambient temperature
Outdoor power board
RT64 Between CN3 pin1 and pin2
Fin temperature
Except MXZ-3A54VA- E4, E5 , E6 , E7 , MXZ-4A71VA- E4 , E5 , E6 ,E7 , MXZ-4A80VA- E2 and MXZ-5A100VA.
135
• Fan motor does not operate or stops operating shortly after starting the operation.
Check of outdoor fan motor
Disconnect CN932 from the inverter P.C.
board or the outdoor electronic control P.C.
board, and measure the resistance of the
outdoor fan motor.
Is the resistance of outdoor fan motor
normal? (Refer to 13-5.)
Yes
No
Turn ON the power supply.
Rotate the outdoor fan motor manually and measure the voltage of
CN931.
Between (+) and (-)
Between (+) and (-)
Between (+) and (-)
(Fixed to either 5V or 0V DC) No
No
Replace the outdoor fan motor.
Does the voltage between each terminal become 5V DC and 0V DC
repeatedly?
Yes
Does the outdoor fan motor rotate smoothly?
Yes
Replace the inverter P.C. board or the outdoor electronic control P.C. board.
136
• When the operation frequency does not go up from lowest frequency.
Check of HPS
MXZ-4A80VA/5A100VA
1. Disconnect the connector CN681 in the electronic control P.C. board.
2. Check the resistance of HPS 1 minute after the outdoor unit power supply was turned OFF.
Infinity
Check the resistance between
each terminal.
Replace HPS.
0Ω
Reconnect CN681.
Turn ON the power supply to the indoor and outdoor unit.
3 minutes later, start EMERGENCY OPERATION.
Is HPS protection displayed
immediately after compressor
starts?
Yes
Replace the electronic control P.C. board.
No
Normal
The other cases
Indoor unit does not operate. (different operating models in multi system)
• When you try to run two indoor units simultaneously, one for cooling and the other for heating, the unit which transmits signal
to the outdoor unit first decides the operation mode.
• When the above situation occurs, set all the indoor units to the same mode, turn OFF the indoor units, then turn them back
ON.
• Though the top of the indoor unit sometimes gets warm, this does not mean malfunction. The reason is that the refrigerant
gas continuously flows into the indoor unit even while it is not operating.
Check of bus-bar voltage
MXZ-3A/4A/5A
•Check the voltage of power supply.
•Confirm outdoor unit failure mode
recall function. (Refer to 13-2.2.)
Confirm LED1 indication lamp on
the outdoor electronic control P.C.
board.
Blink 5 times
Replace the power board.
Blink 6 times
Replace the outdoor electronic control P.C. board.
Turn ON power supply. Start
operation.
Confirm LED1 indication lamp
on the outdoor electronic control P.C. board.
Blink 9 times
Lighting
Replace the outdoor electronic control P.C. board.
Turn ON power supply.
Start operation.
Lighting
Normal
Lighting
Replace the outdoor electronic control P.C. board.
Confirm LED1 indication lamp
on the outdoor electronic control P.C. board.
Blink 9 times
Replace the power board.
Turn OFF power supply before removing P.C. board.
137
13-7. TEST POINT DIAGRAM AND VOLTAGE
1. Inverter P.C. board
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
8V DC
Back side of unit
230V AC
Input
325V DC
FUSE(F801)
T3.15AL250V
5V DC 12V DC
FUSE(F901)
T3.15AL250V
JK,JGO
To
interface
P.C. board
(CN937)
Output to
drive
compressor
(LDW,
LDV,
LDU)
LEV A
(CN791)
5V
GND
5V DC
pulse wave
(CN931)
Fin temperature
thermistor/RT64 (CN662)
Ambient temperature
thermistor /RT65 (CN663)
Outdoor heat
exchanger temperature
thermistor /RT68 (CN661)
To fan motor
Defrost thermistor (RT61)
Ambient temperature thermistor (RT65)
Outdoor heat exchanger
temperature thermistor (RT68)
180
90
160
80
140
70
700
120
60
600
100
50
500
80
40
400
60
30
300
40
20
200
20
10
100
0
0
10 20 30 40 50 60 70 80
Output to drive
outdoor fan motor
(CN932)
(
Discharge temperature
thermistor/RT62 (CN661)
100
Defrost thermistor/RT61 (CN661)
Fin temperature thermistor (RT64)
GND
12V
Primary current
R.V. coil (CN933)
X64
Zero cross
200
To display P.C. board
(CN935)
Front side of unit
(
LEV B
(CN792)
0
-20
Discharge temperature thermistor (RT62)
0
-10
0
10
138
20
30
40
0
10
20
30
40
50
60
70
80
90 100 110 120
(
CN791
(
(
(
(
(
CN602
Serial signal Room B
12~24V DC
Bus-bar
voltage
CN801
325~370
V DC
Input
F801
FUSE
T3.15AL250V
(
LED 3
(–)
(+) (
(
(
12V DC
(–) pulse wave
LEV Room
(+)
A
CN792
12V DC
(–) pulse wave
LEV Room
(+)
B
CN793
12V DC
(–)
pulse wave
LEV Room
(+)
C
CN794
12V DC
(–)
pulse wave
(+) LEV Room
D
CN681 MXZ-4A80VA
High pressure switch
(
(
(
(
LEV E
LED 2
CN795
12V DC
pulse wave
(
CN604
Serial signal Room D
12~24V DC
LED 1
40
30
20
10
0
CN781
(+)
12V
R.V. coil (–)
DC Rush current relay (–)
GND (power board)
(
(
(
(
(
CN931 GND
5V
5V DC
pulse wave
CN932
20-90V AC
(
Resistance (kΩ)
60
400
Temperature (°C)
To fan
motor
(
Gas pipe A thermistor (RT6A)
Gas pipe B thermistor (RT6B)
Gas pipe C thermistor (RT6C)
CN662
Gas pipe D thermistor (RT6D)
(
80
600
-10
Outdoor heat exchanger
temperature thermistor (RT68) (
Temperature (°C)
70
500
Resistance (kΩ)
90
700
0
-20
15V
15V
CN702
(–)
Signal reception
(From power board) GND
5V DC pulse wave
(+)
CN701
Signal transmission (+)
(To power board)
(–)
5V DC pulse wave
CN663 Ambient temperature
thermistor (RT65)
20
Discharge temperature thermistor (RT62) (
Defrost thermistor (RT61) (
100
139
10
100 110 120
90
80
70
60
50
40
30
20
10
0
0
(
(
(
(
30
CN661
40
200
100
Discharge temperature thermistor (RT62)
50
300
(Except MXZ-3A54VA- E4 , E5 , E6 , E7 and MXZ-4A71VA- E4 , E5 , E6 , E7 .)
E1
Outdoor heat exchanger temperature thermistor (RT68)
MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA -
Defrost thermistor (RT61)
Ambient temperature thermistor (RT65)
Gas pipe temperature thermistor (RT6A, 6B, 6C, 6D)
2. Outdoor electronic control P.C. board
SW1
CN603
Serial signal Room C
12~24V DC
CN601
230V AC
Input
Serial signal
Room A
12~24V DC
MXZ-4A80VA -
MXZ-5A100VA
E2
Defrost thermistor (RT61)
Ambient temperature thermistor (RT65)
Outdoor heat exchanger temperature thermistor (RT68)
Discharge temperature thermistor (RT62)
100
700
Resistance (kΩ)
90
Resistance (kΩ)
600
500
400
300
70
60
50
40
200
30
100
0
80
20
0
10
20
30
40
50
60
70
80
90
100 110 120
10
0
-20
-10
0
10
20
30
40
Temperature (°C)
To fan
motor
CN932
20-90V AC
(
(
(
CN781 R.V. coil (–)
(+)
Rush current relay (–)
GND
GND
15V DC
CN702 Signal reception
(From power board)
5V DC pulse wave
CN701 Signal transmission
(To power board)
5V DC pulse wave
CN663 Ambient temperature
thermistor (RT65)
CN661 Outdoor heat exchanger
temperature thermistor (RT68)
Discharge temperature thermistor (RT62)
Defrost temperature thermistor (RT61)
GND
5V DC
5V DC
pulse wave
Temperature (°C)
LED 1
LED 2
LED 3
CN641
Serial signal Room E
(MXZ-5A100VA)
12~24V DC
F931
FUSE
T3.15AL250V
CN631
Serial signal Room D
12~24V DC
CN621
Serial signal Room C
12~24V DC
SW1
SW2
SW871
CN611
Serial signal Room B
12~24V DC
CN601
230V AC
Bus-bar voltage
CN801
325~370 V DC
Input
Input
Serial signal
Room A
12~24V DC
F801
FUSE
T3.15AL250V
{(
–
+
CN796
LEV F
12V DC
pulse wave
(
CN795
LEV Room E (MXZ-5A100VA)
CN794
LEV Room D
CN793
LEV Room C
CN792
LEV Room B
CN681
High pressure switch
140
CN791
LEV Room A
3. Noise filter P.C. board
MXZ-3A54VA -
E1
,
E2
,
E3
,
E4
MXZ-4A71VA -
E1
,
E2
,
E3
,
E4
MXZ-4A80VA -
E1
CN901
To electronic CN902 CN903
control
To power To power
P.C. board
board
board
{
{
230V AC
Input
{
{
CN912
R.V. coil
230V AC
230V AC
Output
F64 FUSE
T2AL250V
NR64 VARISTOR
MXZ-3A54VA -
E5
,
E6
,
E7
CN901
To electronic
control
P.C. board
MXZ-4A71VA CN903
To power
board
{
{
CN912
R.V. coil
230V AC
F911 FUSE
T1AL250V
E5
,
E6
,
E7
CN902
To power
board
{
CN61
230V AC
Output
230V AC
Output
F65
FUSE
T6.3AL250V
230V AC
Input
F64
FUSE
T2AL250V
141
CN61
230V AC
Output
MXZ-4A80VA -
E2
MXZ-5A100VA
CN912
R.V. coil
230V AC
{
{
CN901
To electronic
control
CN902
CN903
P.C. board To power To power
board
board
{
CN61
230V AC
Output
230V AC
Output
F65
FUSE
T6.3AL250V
F64
FUSE
T2AL250V
230V AC
Input
4. Power P.C. board
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
F61 (FUSE)
T20AL250V
Back side of unit
Front side of unit
230V AC
Input
230V AC
Output
R.V.coil
(CN912)
230V AC
12V
R.V.coil
GND
Zero cross
X64
Primary current
(
FUSE (F64)
T3.15AL250V
To inverter P.C.board (CN934)
142
5. Outdoor Power board
Fin temperature thermistor (RT64)
200
MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA
Resistance (kΩ)
180
160
140
120
100
80
60
40
20
0
0
10 20 30 40 50 60 70 80
Temperature (°C)
325-370V DC
Output
(Red)
(+) 1
Connect to the compressor
Voltage among phases: 5V to
180V
(–) 3
Connect to the earth
(White)
CN2
Connect to the controller board
(+)1-5(–): Signal transmission
(To electronic control P.C. board)
5V DC pulse wave
(+)2-5(–): Zero cross signal
3-4 : Not used
(+)6-5(–): 15V
(+)7-5(–): 15V
CN3
Fin temperature thermistor RT64
reception (From
) Signal
electronic control P.C. board)
5V DC pulse wave
CN5
Primary current detection
(Connect to the noise filter)
Connect to the compressor
Voltage among phases: 5V to 180V
Connect to the earth
CN2
Connect to the controller board
(+)1-5(–): Signal transmission
(To electronic control P.C. board)
5V DC pulse wave
(+)2-5(–): Zero cross signal
3-4 : Not used
(+)6-5(–): 15V
(+)7-5(–): 15V
325-370V DC
Output
(Red)
(+) 1
(–) 3
(White)
CN3
Fin temperature thermistor RT64
reception (From
) Signal
electronic control P.C. board)
5V DC pulse wave
CN5
Primary current detection
(Connect to the noise filter)
143
6. Display P.C. board
MXZ-2A30VA
MXZ-2A40VA
MXZ-2A52VA
)
To inverter P.C. board (CN936)
5V
SW1
GND
LED1
LED2
7. Interface P.C. board
MXZ-2A40VA
MXZ-2A52VA
To inverter P.C. board (CN938)
)
MXZ-2A30VA
5V
GND
Serial signal
room A
Serial signal
room B
230V AC
144
14
DISASSEMBLY INSTRUCTIONS
<"Terminal with locking mechanism" Detaching points>
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
(1) Slide the sleeve and check if there is a locking lever or not.
(2) The terminal with this connector has the
locking mechanism.
Sleeve
Locking lever
Slide the sleeve.
Pull the terminal while
pushing the locking
lever.
Hold the sleeve, and
pull out the terminal
slowly.
Connector
14-1. MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA
PHOTOS
OPERATING PROCEDURE
Photo 1
1. Removing the cabinet
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Remove the screw fixing the service panel.
Pull down the service panel and remove it.
Disconnect the power supply and indoor/outdoor connecting wire.
Remove the screws fixing the top panel.
Remove the top panel.
Remove the screws fixing the cabinet.
Remove the cabinet.
Remove the screws fixing the back panel.
Remove the back panel.
Screws
of the
top panel
Screw of
the cabinet
Screws of
the top panel
Back Screw
panel of the
service
panel
Direction to
remove
Hooks
Screws of
the cabinet
145
Service
panel
OPERATING PROCEDURE
PHOTOS
2. Removing the inverter assembly, inverter P.C. board
and power P.C. board
(1) Remove the top panel, cabinet and service panel (Refer to 1).
(2) Disconnect the power supply and indoor/outdoor
connecting wire and remove the back panel (Refer to 1).
(3) Disconnect the earth wires, the lead wire to the reactor and
the following connectors;
<Power P.C. board>
CN912 (R.V coil)
<Inverter P.C. board>
CN931, CN932 (Fan motor)
CN661 (Defrost thermistor, discharge temperature
thermistor and outdoor heat exchanger
temperature thermistor)
CN663 (Ambient temperature thermistor)
CN791, CN792 (LEV A, LEV B)
(4) Remove the compressor connector (CN61).
(5) Remove the screws fixing the relay panel.
(6) Remove the inverter assembly.
(7) Disconnect all connectors and lead wires on the inverter P.C.
board.
(8) Remove the inverter P.C. board from the inverter assembly.
(9) Remove the screw fixing the power P.C. board.
(10) Disconnect all connectors and lead wires on the power P.C.
board.
(11) Remove the power P.C. board from the inverter assembly.
Photo 2
Screws of the
relay panel
Inverter
assembly
Screws of
the earth
wires
Photo 3
Heat sink
Inverter
P.C. board
Power
P.C. board
3. Removing R.V. coil
(1) Remove the top panel, cabinet and service panel
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor
connecting wire and remove the back panel (Refer to 1).
(3) Remove the inverter assembly (Refer to 2).
(4) Remove the R.V. coil.
Compressor
connector
(CN61)
4. Removing the discharge temperature thermistor,
defrost thermistor and outdoor heat exchanger
temperature thermistor
Photo 4
Screw of the
power P.C. board
R.V. coil
(1) Remove the top panel, cabinet and service panel (Refer to 1).
(2) Disconnect the power supply and indoor/outdoor connecting
wire and remove the back panel (Refer to 1).
(3) Remove the inverter assembly (Refer to 2).
(4) Pull out the discharge temperature thermistor from its
holder.
(5) Pull out the defrost thermistor from its holder (Photo 5).
(6) Pull out the outdoor heat exchanger temperature thermistor
from its holder (Photo 5).
Discharge temperature thermistor
146
OPERATING PROCEDURE
PHOTOS
5. Removing outdoor fan motor
Photo 5
(1) Remove the top panel, cabinet and service panel
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor
connecting wire.
(3) Disconnect the connectors for outdoor fan motor.
(4) Remove the propeller nut.
(5) Remove the propeller.
(6) Remove the screws fixing the fan motor (Photo 6).
(7) Remove the fan motor.
Outdoor heat
exchanger
temperature
thermistor
6. Removing the compressor and 4-way valve
(1) Remove the top panel, cabinet and service panel
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor
connecting wire and remove the back panel (Refer to 1).
(3) Remove the inverter assembly (Refer to 2).
(4) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
(5) Detach the welded part of the suction and the discharge pipe
connected with compressor.
(6) Remove the nuts of compressor legs.
(7) Remove the compressor.
(8) Detach the welded part of pipes connected with 4-way valve
(Photo 7).
Defrost
thermistor
Photo 6
Screws of the outdoor fan motor
Propeller
Propeller nut
Photo 7
Welded parts of 4-way valve
147
14-2. MXZ-3A54VA -
E1
,
E2
,
E3
,
E4
MXZ-4A71VA -
E1
,
E2
,
E3
OPERATING PROCEDURE
,
E4
PHOTOS
1. Removing the compressor
Photo 1
Screws of the
top panel
(1) Remove the screws of the top panel, and remove the top
panel.
(2) Remove the screws of the service panel, and remove the
service panel.
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
(4) Remove the screws of the cabinet, and remove the cabinet.
(5) Remove the screws of the back panel, and remove the back
panel (Photo 3).
(6) Disconnect the compressor lead wire from terminal of the
compressor (U, V, W).
(7) Disconnect the outdoor electronic control P.C. board
connectors:
CN661, CN662 (MXZ-3A54/4A71VA- E1 , E2 , E3 ), CN663,
CN791, CN792, CN793, CN794 (MXZ-4A71VA- E1 , E2 , E3 , E4 ),
CN795, CN931, CN932
Disconnect the noise filter P.C. board connector:
CN912
(8) Remove the screws of the electrical parts, and remove the
electrical parts (Photo 4).
(9) Remove the propeller.
(10) Remove the screws of the separator, and remove the
separator (Photo 6).
(11) Remove the sound proof felt (Photo 6).
(12) Detach the welded parts of the compressor suction and discharge pipes (Photo 5).
(13) Remove the compressor nuts and remove the compressor.
Screws of
the cabinet
Screws of
service
panel
Screw of
the cabinet
Screws of the cabinet
Photo 2
Screws of the
top panel
Screws of the
cabinet
148
Screws of the cabinet
PHOTOS
OPERATING PROCEDURE
Photo 3
Screw of
the rear guard
Screw of the
back panel
Photo 5
R.V. coil
4 way valve
Screws of
the back panel
LEV coil E
Expansion valve E
Suction pipe
welded part
Screws of
the back panel
Discharge
pipe welded part
Screw of the
back panel
Photo 4
Compressor nuts
Screws of
the electrical
parts
Photo 6
2. Removing the fan motor
(1) Remove the top panel, the service panel, and the cabinet
(Photo 1, 2).
(2) Disconnect the connector CN931 and CN932 on the outdoor
electronic control P.C. board.
(3) Remove the propeller.
(4) Remove the fan motor.
Screws of the outdoor fan motor
Propeller
Sound
proof
felt
Propeller nut
Separator
149
OPERATING PROCEDURE
PHOTOS
3. Removing the 4-way valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, the cabinet, and the back panel
(Photo 1, 2, 3).
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
Photo 7
4 way valve
R.V. coil
(4) Remove the electrical parts (Photo 4).
(5) Detach the welded parts of 4-way valve and pipe (Photo 7).
Welded parts
4. Removing the expansion valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, the cabinet, and the back panel
(Photo 1, 2, 3).
(Gas recovery is not required if the unit is pumped down.)
(3) Remove the electrical parts for removing LEV E (Photo 4, 5).
(4) Remove the LEV coils.
(5) Detach the welded parts of expansion valves and pipes.
Photo 8
Expansion
valves
LEV coils
5. Removing the reactor
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, cabinet, back panel, and the
electrical parts (Photo 1, 2, 3, 4).
(3) Disconnect the reactor lead wire from the terminal of the
reactor.
(4) Remove the screws of the reactor, and remove the reactor
(Photo 9).
Photo 9
Screws of the reactor
150
14-3. MXZ-3A54VA -
E5
,
E6
,
E7
MXZ-4A71VA -
E5
,
E6
,
E7
OPERATING PROCEDURE
PHOTOS
1. Removing the compressor
Photo 1
Screws of the
top panel
(1) Remove the screws of the top panel, and remove the top
panel.
(2) Remove the screws of the service panel, and remove the
service panel.
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
(4) Remove the screws of the cabinet, and remove the cabinet.
(5) Remove the screws of the back panel, and remove the back
panel (Photo 3).
(6) Disconnect the compressor lead wire from terminal of the
compressor (U, V, W).
(7) Disconnect the outdoor electronic control P.C. board
connectors:
CN661, CN663, CN791, CN792, CN793,
CN794 (MXZ-4A71VA- E5 , E6 , E7 ), CN795, CN931, CN932
Disconnect the noise filter P.C. board connector:
CN912
(8) Remove the screws of the electrical parts, and remove the
electrical parts (Photo 4).
(9) Remove the propeller.
(10) Remove the screws of the separator, and remove the
separator (Photo 6).
(11) Remove the sound proof felt (Photo 6).
(12) Detach the welded parts of the compressor suction and discharge pipes (Photo 5).
(13) Remove the compressor nuts and remove the compressor.
Screws of
the cabinet
Screws of
service
panel
Screws of the cabinet
Photo 2
Screws of the
top panel
2. Removing the electronic control P.C. board
(1) Remove the screws of the sub panel.
(2) Remove the sub panel.
(3) Disconnect all connectors and lead wires on the electronic
control P.C. board.
(4) Remove the electronic control P.C. board.
151
Screw of
the cabinet
Screws of the
cabinet
Screws of
the cabinet
Screws of the
sub panel
PHOTOS
OPERATING PROCEDURE
Photo 3
Screw of the rear guard
Screw of the
back panel
Photo 5
R.V. coil
4 way valve
Screws of
the back panel
LEV coil E
Expansion valve E
Suction pipe
welded part
Screws of
the back panel
Screw of the
back panel
Discharge
pipe welded part
Photo 4
Compressor nuts
Screws of
the electrical
parts
3. Removing the fan motor
(1) Remove the top panel, the service panel, and the cabinet
(Photo 1, 2).
(2) Disconnect the connector CN931 and CN932 on the outdoor
electronic control P.C. board.
(3) Remove the propeller.
(4) Remove the fan motor.
Photo 6
Screws of the outdoor fan motor
Propeller nut
Propeller
152
Separator
Sound
proof
felt
OPERATING PROCEDURE
PHOTOS
4. Removing the 4-way valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, the cabinet, and the back panel
(Photo 1, 2, 3).
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
Photo 7
4 way valve
(4) Remove the electrical parts (Photo 4).
(5) Detach the welded parts of 4-way valve and pipe (Photo 7).
R.V. coil
Welded parts
5. Removing the expansion valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, the cabinet, and the back panel
(Photo 1, 2, 3).
(Gas recovery is not required if the unit is pumped down.)
(3) Remove the electrical parts for removing LEV E (Photo 4, 5).
(4) Remove the LEV coils.
(5) Detach the welded parts of expansion valves and pipes.
Photo 8
Expansion
valves
LEV coils
6. Removing the reactor
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, cabinet, back panel, and the
electrical parts (Photo 1, 2, 3, 4).
(3) Disconnect the reactor lead wire from the terminal of the
reactor.
(4) Remove the screws of the reactor, and remove the reactor
(Photo 9).
Photo 9
Screws of the reactor
153
14-4. MXZ-4A80VA -
E1
OPERATING PROCEDURE
PHOTOS
1. Removing the compressor
Photo 1
(1) Remove the screws of the top panel, and remove the top
panel.
(2) Remove the screws of the service panel, and remove the
service panel.
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
(4) Remove the screws of the front panel, and remove the front
panel.
(5) Disconnect the compressor lead wire from terminal of
compressor (U, V, W).
(6) Disconnect the outdoor electronic control P.C. board
connectors:
CN661, CN662 , CN663, CN681, CN791, CN792, CN793,
CN794, CN795, CN931, CN932
Disconnect the noise filter P.C. board connector:
CN912
(7) Remove the screws of the electrical parts, and remove the
electrical parts.
(8) Remove the propeller.
(9) Remove the screws of the separator, and remove the
separator.
(10) Remove the sound proof felt.
(11) Detach the welded parts of the compressor suction and
discharge pipes (Photo 3).
(12) Remove the compressor nuts and remove the compressor.
Screws of the top panel
Screws of
service
panel
Screws of the front panel
Photo 2
Screws
of the
electrical
parts
Electronic
control
P.C.
board
Photo 3
LEV coil E
Expansion
valve E
Suction
pipe
welded
part
Discharge
pipe welded part
Terminal
154
PHOTOS
OPERATING PROCEDURE
Photo 4
2. Removing the fan motor
(1) Remove the top panel, the service panel, and the front panel
(Photo 1).
(2) Disconnect the connector CN931 and CN932 on the outdoor
electronic control P.C. board.
(3) Remove the propeller.
(4) Remove the fan motor.
Screws of the outdoor fan motor
Propeller
Sound
proof
felt
Propeller nut
3. Removing the 4-way valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, rear panel, and pipe cover.
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
Separator
Compressor nuts
Photo 5
4 way valve
(4) Remove the electrical parts (Photo 2).
(5) Detach the welded parts of 4-way valve and pipe (Photo 5).
R.V. coil
Welded parts
4. Removing the expansion valve
Photo 6
(1) Remove the top panel (Photo 1).
(2) Remove the service panel (Photo 1).
(Gas recovery is not required if the unit is pumped down.)
(3) Remove the front panel for removing LEV E (Photo 1).
(4) Remove the electrical parts for removing LEV E (Photo 2,3).
(5) Remove the LEV coils.
(6) Detach the welded parts of expansion valves and pipes.
Expansion
valves
LEV coils
155
OPERATING PROCEDURE
PHOTOS
5. Removing the reactor
(1) Remove the top panel (Photo 1).
(2) Disconnect the reactor lead wire.
(3) Remove the screws of the reactor, and remove the reactor
(Photo 7).
Photo 7
Screws of the reactor
156
14-5. MXZ-4A80VA -
E2
MXZ-5A100VA
OPERATING PROCEDURE
PHOTOS
1. Removing the compressor
Photo 1
(1) Remove the screws of the top panel, and remove the top
panel.
(2) Remove the screws of the service panel, and remove the
service panel.
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
(4) Remove the screws of the front panel, and remove the front
panel.
(5) Remove the screws of the rear panel, and remove the rear
panel.
(6) Disconnect the compressor lead wire from terminal of
compressor (U, V, W).
(7) Disconnect the outdoor electronic control P.C. board
connectors:
CN661, CN663, CN681, CN791, CN792, CN793, CN794,
CN795 (MXZ-5A100VA), CN796, CN931, CN932
Disconnect the noise filter P.C. board connector:
CN912
(8) Remove the screws of the electrical parts, and remove the
electrical parts.
(9) Remove the propeller.
(10) Remove the screws of the separator, and remove the
separator.
(11) Remove the sound proof felt.
(12) Detach the welded parts of the compressor suction and
discharge pipes (Photo 4).
(13) Remove the compressor nuts and remove the compressor.
Screws of the top panel
Screws of
the service
panel
Screws of the front panel
Photo 2
Screws of the top panel
Screws of
the side panel
Photo 3
Screws of the
service panel
Screws
of the
electrical
parts
Screws of
the rear panel
Photo 4
Suction
pipe
welded
part
Discharge
pipe welded part
Compressor nuts (3 places)
157
PHOTOS
OPERATING PROCEDURE
Photo 5
2. Removing the fan motor
Screws of the outdoor fan motor
(1) Remove the top panel, the service panel, and the front panel
(Photo 1).
(2) Disconnect the connector CN931 and CN932 on the outdoor
electronic control P.C. board.
(3) Remove the propeller.
(4) Remove the fan motor.
Propeller
Propeller nut
Sound
proof felt
Separator
3. Removing the 4-way valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, rear panel, and pipe cover.
(3) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge
shows 0 kg/cm2 (0 MPa).
Photo 6
4 way valve
R.V. coil
(4) Remove the electrical parts (Photo 3).
(5) Detach the welded parts of 4-way valve and pipe.
Welded parts
4. Removing the expansion valve
Photo 7
(1) Remove the top panel (Photo 1,2).
(2) Remove the service panel (Photo 1).
(Gas recovery is not required if the unit is pumped down.)
(3) Remove the font panel for removing LEV F (Photo 1).
(4) Remove the electrical parts for removing LEV F (Photo 3).
(5) Remove the LEV coils.
(6) Detach the welded parts of expansion valves and pipes.
LEV coil F
Expansion valve F
LEV coils
Expansion
valves
158
OPERATING PROCEDURE
PHOTOS
5. Removing the reactor
(1) Remove the top panel (Photo 1).
(2) Disconnect the reactor lead wire.
(3) Remove the screws of the reactor, and remove the reactor.
Photo 8
Screws of the reactor
159
15
PARTS LIST (non-RoHS compliant)
MXZ-2A40VA - E1 MXZ-2A52VA - E1
15-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
17
10
14
16 15
18
19
13
1
11
12
3
4
2
160
5
6
7
8
9
PARTS LIST (non-RoHS compliant)
MXZ-2A40VA -
E1
MXZ-2A52VA -
E1
15-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
Part numbers that are circled are not shown in the illustration.
Symbol
No.
Part No.
Part Name
Diagram
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
20
E02
21 E02
22 E02
927
927
927
A45
A47
065
927
927
A47
A47
735
A48
A47
929
929
929
927
A47
A47
339
838
735
A47
232
521
501
290
900
506
661
662
245
233
640
493
961
523
293
515
297
630
301
936
936
640
493
CABINET
GRILLE
PROPELLER
BASE
COMPRESSOR
COMPRESSOR RUBBER SET
STOP VALVE (GAS)
STOP VALVE (LIQUID)
SERVICE PANEL
BACK PANEL
EXPANSION VALVE
EXPANSION VALVE COIL
4-WAY VALVE
CONDENSER NET
SEPARATOR
MOTOR SUPPORT
TOP PANEL
OUTDOOR HEAT EXCHANGER
OUTDOOR FAN MOTOR
CAPILLARY TUBE
CAPILLARY TUBE
EXPANSION VALVE
EXPANSION VALVE COIL
Q'ty/unit
in Wiring
MC
LEV B
MF
LEV A
161
MXZ-2A40VA1
1
1
1
1
3
2
2
1
1
1
1
1
1
1
1
1
1
1
4
2
1
1
E1
MXZ-2A52VA1
1
1
1
1
3
2
2
1
1
1
1
1
1
1
1
1
1
1
4
2
1
1
Remarks
E1
SNB130FKCH
3RUBBERS/SET
9.52
6.35
ROOM B
RC0J503.0 1.4 600
3.0 2.0 200
ROOM A
PARTS LIST (non-RoHS compliant)
MXZ-2A40VA - E1 MXZ-2A52VA - E1
15-2. OUTDOOR UNIT ELECTRICAL PARTS
12
13
11
10
9
8
1
2
3
4
5
6
7
Part numbers that are circled are not shown in the illustration.
No.
Part No.
1
2
3
4
5
6
7
8
9
10
11
12
838
A47
A47
A47
A47
A47
A47
A47
735
A47
935
935
A47
A48
127
661
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
13
E02
14 E02
15 E02
337
440
454
490
308
309
329
337
382
374
374
374
451
451
382
385
Part Name
Q'ty/unit
Symbol
in Wiring
Diagram MXZ-2A40VA- E1 MXZ-2A52VA-
REACTOR
L64
POWER P.C. BOARD
INTERFACE P.C. BOARD
R.V. COIL
21S4
THERMISTOR SET
RT61,62,68
AMBIENT TEMPERATURE THERMISTOR RT65
DISPLAY P.C. BOARD
L65
REACTOR
F61
FUSE
TERMINAL BLOCK
TB1
TERMINAL BLOCK
TB3
TB2
TERMINAL BLOCK
INVERTER P.C. BOARD
INVERTER P.C. BOARD
F64,801,901
FUSE
NR61,62,63,64
VARISTOR
162
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
E1
Remarks
10A 23mH
DEFROST, DISCHARGE
OUTDOOR HEAT EXCHANGER
2A 25mH
T20AL250V
Power supply
Indoor unit connecting
Indoor unit connecting
Including heat sink and RT64
Including heat sink and RT64
T3.15AL250V
PARTS LIST (non-RoHS compliant)
MXZ-2A40VA - E1 MXZ-2A52VA 15-3. DRAIN SOCKET
E1
Outdoor unit 42 drain hole
1
Soft vinyl chloride hose of
25 mm inside diameter
No.
Parts No.
Parts Name
Q'ty/unit
Symbol
in Wiring
MXZ-2A40VA- E1 MXZ-2A52VADiagram
1 E02 838 704 DRAIN SOCKET
1
163
1
E1
Remarks
PARTS LIST (non-RoHS compliant)
MXZ-3A54VA - E1 , E2
MXZ-4A71VA - E1 , E2
15-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
23
21
22
24
20
19
18
17
16
1
15
12
2
11
3
4
5 6 7 8
164
9
10
13
14
PARTS LIST (non-RoHS compliant)
MXZ-3A54VA - E1 , E2
MXZ-4A71VA - E1 , E2
15-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Parts No.
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
E02
939
817
939
939
065
851
939
851
938
851
939
851
938
939
939
979
939
939
939
939
939
938
853
851
891
819
939
939
939
938
939
938
938
232
009
521
900
506
640
494
640
494
640
493
640
493
290
666
666
667
233
245
661
662
959
640
493
961
297
523
630
515
937
936
936
299
Parts Name
CABINET
HANDLE
GRILLE
COMPRESSOR
COMPRESSOR RUBBER SET
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
BASE
UNION(GAS)
UNION(GAS)
UNION(LIQUID)
BACK PANEL
SERVICE PANEL
BALL VALVE (GAS) 5/8
BALL VALVE (LIQUID) 3/8
POWER RECEIVER
EXPANSION VALVE
LEV COIL
4-WAY VALVE
TOP PANEL
REAR GUARD
OUTDOOR HEAT EXCHANGER
MOTOR SUPPORT
CAPILLARY TUBE
CAPILLARY TUBE
CAPILLARY TUBE
OIL SEPARATOR
Q'ty/unit
Symbol
MXZ-4A71VAMXZ-3A54VAin Wiring
Diagram
E1
E2
E1
E2
MC
1
1
1
1
3
1
1
1
1
3
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
1
1
1
1
1
8
3
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
8
3
1
1
LEV D
LEV C
LEV B
LEV A
LEV E
165
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
1
4
1
1
1
1
1
1
1
1
1
1
1
1
8
4
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
1
4
1
1
1
1
1
1
1
1
1
1
1
1
8
4
1
1
Remarks
SNB130FLDH1
3RUBBERS SET
D room
D room
C room
C room
B room
B room
A room
A room
9.52
12.7
6.35
15.88
9.52
E
3.6
4.0
2.5
2.4 500
2.8 100
0.6 1000
PARTS LIST (non-RoHS compliant)
MXZ-3A54VA - E1 , E2
MXZ-4A71VA - E1 , E2
15-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
12
11
10
9
8
1
3
2
4
5
15-6. ACCESSORY
6
17
16
166
7
PARTS LIST (non-RoHS compliant)
MXZ-3A54VA - E1 , E2
MXZ-4A71VA - E1 , E2
15-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
Parts No.
1 E02 851 501
2 E02 938 301
3 E02 939 440
E02 938 450
4
E02 939 450
5 E02 938 444
6 E02 927 374
7 E02 823 375
E02 938 307
8
E02 939 307
9 E02 939 490
10 E02 938 308
11 E02 938 309
12 E02 938 337
13 E02 127 382
14 E02 737 382
15 E02 735 385
Parts Name
PROPELLER
OUTDOOR FAN MOTOR
POWER BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
NOISE FILTER P.C. BOARD
TERMINAL BLOCK
TERMINAL BLOCK
GAS PIPE TEMPERATURE THERMISTOR SET
GAS PIPE TEMPERATURE THERMISTOR SET
R.V. COIL
THERMISTOR SET
AMBIENT TEMPERATURE THERMISTOR
REACTOR
FUSE
FUSE
FUSE&VARISTOR SET
Symbol
in Wiring
Diagram
MF
TB2~5
TB1
RT6A,B,C
RT6A,B,C,D
21S4
RT61,62,68
RT65
L
F801
F911
F64,NR64
Q'ty/unit
MXZ-3A54VA-
MXZ-4A71VA-
E1
E2
E1
E2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
3
1
1
1
1
4
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Remarks
RC0J60Including heat sink and RT64
Indoor unit connecting
Power supply
DEFROST, DISCHARGE
OUTDOOR HEAT EXCHANGER
20A 600μH
T3.15AL250V
T1AL250V
T2AL250V
15-6. ACCESSORY
No.
Parts No.
Parts Name
Q'ty/unit
Symbol
MXZ-4A71VAin Wiring MXZ-3A54VADiagram
E1
E2
E1
E2
16 E02 817 704 DRAIN SOCKET
17 E02 444 705 DRAIN CAP
1
2
167
1
2
1
2
1
2
Remarks
PARTS LIST (non-RoHS compliant)
MXZ-4A80VA - E1
15-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
25 24 23
22
21
19 18
20
2
14
15
17
16
1
2
5
13
6
11
7 8 9 10
3
4
168
12
PARTS LIST (non-RoHS compliant)
MXZ-4A80VA - E1
15-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
Parts No.
1
2
3
4
5
6
M21 TK0 232
M21 TK0 027
M21 TK5 010
M21 TK0 245
T92 500 801
T2W TK0 505
R01 E39 401
T2W TK0 654
R01 E39 401
T2W TK0 653
R01 E39 401
T2W TK0 652
R01 E39 401
T2W TK0 651
M21 TK0 290
M21 42E 644
T2W TK0 247
M21 TK5 667
M21 TK0 667
M21 TK0 248
T2W TK0 959
M21 G0H 642
M21 NT1 646
T2W WW8 401
T2W TK0 651
M21 TK0 297
T2W E40 523
M21 YH1 630
M21 TK0 249
M21 SJ4 937
M21 TK0 936
T2W E59 936
T2W YH1 656
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Parts Name
FRONT PANEL
HANDLE ASSEMBLY
GRILLE
SERVICE PANEL
COMPRESSOR
COMPRESSOR RUBBER SET
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
BASE ASSEMBLY
UNION
PIPE COVER
BALL VALVE (LIQUID) 3/8
BALL VALVE (GAS) 5/8
REAR PANEL
POWER RECEIVER
4-WAY VALVE
HIGH PRESSURE SWITCH
EXPANSION VALVE
LEV COIL
TOP PANEL
REAR GUARD
OUTDOOR HEAT EXCHANGER
SIDE PANEL
CAPILLARY TUBE
CAPILLARY TUBE
CAPILLARY TUBE
OIL SEPARATOR
Symbol
in Wiring
Diagram
MC
LEV D
LEV C
LEV B
LEV A
HPS
LEV E
169
Q'ty/unit
MXZ-4A80VA1
2
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
Remarks
E1
TNB220FMCH
3RUBBERS SET
D room
D room
C room
C room
B room
B room
A room
A room
12.7, 9.52, 6.35 SET
9.52
15.88
4.8 MPa (48.9 kg/cm2)
E
4.0
4.0
2.5
2.4 400
2.8 90
0.6 1000
PARTS LIST (non-RoHS compliant)
MXZ-4A80VA - E1
15-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
12
11
10
9
8
7
1
15-9. ACCESSORY
2
3
4
5
16
170
6
PARTS LIST (non-RoHS compliant)
MXZ-4A80VA - E1
15-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Parts No.
M21
M21
T2W
T2W
M21
T2W
T2W
T2W
T2W
T2W
M21
M21
T2W
T2W
T2W
TK0
TK0
YH1
YH1
TK0
YH1
YH1
E64
E70
TK0
G0H
90V
YH1
YH1
E88
501
301
440
451
337
424
376
376
307
398
308
309
381
382
313
Parts Name
Symbol
in Wiring
Diagram
PROPELLER
MF
OUTDOOR FAN MOTOR
POWER BOARD
ELECTRONIC CONTROL P.C. BOARD
L
REACTOR
NOISE FILTER P.C. BOARD
TERMINAL BLOCK
TB2~5
TERMINAL BLOCK
TB1
GAS PIPE TEMPERATURE THERMISTOR RT6A,B,C,D
R.V. COIL
21S4
THERMISTOR SET
RT61,62,68
AMBIENT TEMPERATURE THERMISTOR RT65
FUSE
F801
FUSE
F911
FUSE&VARISTOR SET
F64,NR64
Q'ty/unit
MXZ-4A80VA-
E1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
Remarks
PM8H60Including heat sink and RT64
20A 600μH
Indoor unit connecting
Power supply
DEFROST, DISCHARGE,
OUTDOOR HEAT EXCHANGER
T3.15AL250V
T1AL250V
T2AL250V
15-9. ACCESSORY
No.
Parts No.
Parts Name
Symbol
in Wiring
Diagram
16 T2W E59 704 DRAIN SOCKET ASSEMBLY
Q'ty/unit
MXZ-4A80VA1
171
E1
Remarks
DRAIN SOCKET
DRAIN CAP 2
1
16
RoHS PARTS LIST (RoHS compliant)
MXZ-2A30VA -
E1
,
E2
MXZ-2A40VA -
E1
,
E2
MXZ-2A52VA -
E1
,
E2
16-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
17
10
14
16 15
18
19
13
1
11
12
3
4
2
172
5
6
7
8
9
RoHS PARTS LIST (RoHS compliant)
MXZ-2A30VA - E1 , E2 MXZ-2A40VA - E1 , E2 MXZ-2A52VA - E1 , E2
16-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
RoHS
Part numbers that are circled are not shown in the illustration.
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
Symbol
Part No.
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
927
927
927
A45
A47
B70
C04
B93
065
927
927
A47
A47
735
A48
A47
927
929
838
929
927
929
927
927
A47
B70
A47
339
838
735
A47
232
521
501
290
900
900
900
900
506
661
662
245
233
640
493
961
961
523
523
293
293
515
515
297
630
630
301
936
936
640
493
Part Name
CABINET
GRILLE
PROPELLER
BASE
COMPRESSOR
COMPRESSOR
COMPRESSOR
COMPRESSOR
COMPRESSOR RUBBER SET
STOP VALVE (GAS)
STOP VALVE (LIQUID)
SERVICE PANEL
BACK PANEL
EXPANSION VALVE
EXPANSION VALVE COIL
4-WAY VALVE
4-WAY VALVE
CONDENSER NET
CONDENSER NET
SEPARATOR
SEPARATOR
MOTOR SUPPORT
MOTOR SUPPORT
TOP PANEL
OUTDOOR HEAT EXCHANGER
OUTDOOR HEAT EXCHANGER
OUTDOOR FAN MOTOR
CAPILLARY TUBE
CAPILLARY TUBE
EXPANSION VALVE
EXPANSION VALVE COIL
Q'ty/unit
in Wiring MXZ-2A30VA- MXZ-2A40VA- MXZ-2A52VADiagram E1
E1
E2
E1
E2
E2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MC
1
1
MC
1
MC
1
MC
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LEV B
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MF
4
4
4
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
LEV A
173
Remarks
SNB130FKCH
KNB092FEDH
SNB130FKMH
KNB073FGDH
3RUBBERS/SET
9.52
6.35
ROOM B
RC0J503.0 1.4 600
3.0 2.0 200
ROOM A
RoHS PARTS LIST (RoHS compliant)
MXZ-2A30VA - E1 , E2 MXZ-2A40VA - E1 , E2 MXZ-2A52VA 16-2. OUTDOOR UNIT ELECTRICAL PARTS
13 12
E1
,
E2
11
10
9
8
1
2
3
4
5
6
7
No.
1
2
3
4
5
6
7
8
9
10
11
12
RoHS
Part numbers that are circled are not shown in the illustration.
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
13
G
G
G
14 G
15 G
Part No.
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
838
A47
A47
A47
A47
A47
A47
A47
735
A47
935
935
A47
A48
B70
B71
C04
C58
127
661
337
440
454
490
308
309
329
337
382
374
374
374
451
451
451
451
451
451
382
385
Part Name
Q'ty/unit
Symbol
in Wiring MXZ-2A30VA- MXZ-2A40VA- MXZ-2A52VADiagram E1
E1
E2
E1
E2
E2
REACTOR
L64
POWER P.C. BOARD
INTERFACE P.C. BOARD
R.V. COIL
21S4
THERMISTOR SET
RT61,62,68
AMBIENT TEMPERATURE THERMISTOR RT65
DISPLAY P.C. BOARD
REACTOR
L65
FUSE
F61
TERMINAL BLOCK
TB1
TERMINAL BLOCK
TB3
TERMINAL BLOCK
TB2
INVERTER P.C. BOARD
INVERTER P.C. BOARD
INVERTER P.C. BOARD
INVERTER P.C. BOARD
INVERTER P.C. BOARD
INVERTER P.C. BOARD
FUSE
F64,801,901
VARISTOR
NR61,62,63,64
174
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Remarks
10A 23mH
DEFROST, DISCHARGE
OUTDOOR HEAT EXCHANGER
2A 25mH
T20AL250V
Power supply
Indoor unit connecting
Indoor unit connecting
Including heat sink and RT64
Including heat sink and RT64
Including heat sink and RT64
Including heat sink and RT64
Including heat sink and RT64
Including heat sink and RT64
T3.15AL250V
RoHS PARTS LIST (RoHS compliant)
MXZ-2A30VA - E1 , E2 MXZ-2A40VA 16-3. DRAIN SOCKET
E1
,
E2
MXZ-2A52VA -
E1
,
E2
Outdoor unit 42 drain hole
1
No.
RoHS
Soft vinyl chloride hose of
25 mm inside diameter
Parts No.
Parts Name
Q'ty/unit
Symbol
MXZ-2A30VAMXZ-2A40VAMXZ-2A52VAin Wiring
Diagram
E1
E1
E2
E1
E2
E2
1 G E12 838 704 DRAIN SOCKET
1
175
1
1
1
1
1
Remarks
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E1 , E2 , E3 , E4
MXZ-4A71VA - E1 , E2 , E3 , E4
16-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
23
21
22
24
20
19
18
17
16
1
15
12
2
11
3
4
5 6 7 8
176
9
10
13
14
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E1 , E2 , E3 , E4
MXZ-4A71VA - E1 , E2 , E3 , E4
16-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
No.
RoHS
Part numbers that are circled are not shown in the illustration.
Parts No.
1 G E12 939
2 G E12 817
3 G E12 939
G E12 939
4 G E12 C06
G E12 C18
5 G E12 065
G E12 851
6
G E12 939
G E12 851
7
G E12 938
G E12 851
8
G E12 939
G E12 851
9
G E12 938
10 G E12 939
G E12 C06
G E12 C18
11
G E12 C07
G E12 C19
G E12 C06
12
G E12 C18
13 G E12 939
14 G E12 939
15 G E12 C06
16 G E12 C06
G E12 938
17
G E12 C18
18 G E12 853
19 G E12 819
G E12 891
20
G E12 C18
21 G E12 819
22 G E12 939
23 G E12 939
24 G E12 939
25 G E12 938
26 G E12 939
27 G E12 938
28 G E12 938
232
009
521
900
900
900
506
640
494
640
494
640
493
640
493
290
666
666
666
666
667
667
233
245
661
662
959
959
640
493
961
961
297
523
630
515
937
936
936
299
Parts Name
CABINET
HANDLE
GRILLE
COMPRESSOR
COMPRESSOR
COMPRESSOR
COMPRESSOR RUBBER SET
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
BASE
UNION(GAS)
UNION(GAS)
UNION(GAS)
UNION(GAS)
UNION(LIQUID)
UNION(LIQUID)
BACK PANEL
SERVICE PANEL
BALL VALVE (GAS) 5/8
BALL VALVE (LIQUID) 3/8
POWER RECEIVER
POWER RECEIVER
EXPANSION VALVE
LEV COIL
4-WAY VALVE
4-WAY VALVE
TOP PANEL
REAR GUARD
OUTDOOR HEAT EXCHANGER
MOTOR SUPPORT
CAPILLARY TUBE
CAPILLARY TUBE
CAPILLARY TUBE
OIL SEPARATOR
Symbol
in Wiring
Diagram
MC
MC
MC
Q'ty/unit
MXZ-3A54VA-
MXZ-4A71VA-
E1
E2
E3
E4
E1
E2
E3
E4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
3
1
1
3
LEV D
LEV C
LEV B
LEV A
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
1
1
3
3
1
3
1
1
1
1
1
1
1
1
1
Remarks
SNB130FLDH1
SNB130FLEH1
SNB130FGBH1
3RUBBERS SET
D room
D room
C room
C room
B room
B room
A room
A room
9.52
9.52
12.7
12.7
6.35
6.35
3
1
1
1
4
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8
4
1
1
1
1
1
1
8
4
1
1
1
1
1
1
8
4
1
1
1
LEV E
177
3
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8
3
1
1
1
1
1
1
8
3
1
1
1
1
1
1
8
3
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
8
3
1
1
4
1
1
1
1
15.88
9.52
1
1 E
1
1
1
1
1
1
8
4
1
1
3.6
4.0
2.5
2.4 500
2.8 100
0.6 1000
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E1 , E2 , E3 , E4
MXZ-4A71VA - E1 , E2 , E3 , E4
16-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
12
11
10
9
8
1
3
2
4
5
16-6. ACCESSORY
6
17
16
178
7
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E1 , E2 , E3 , E4
MXZ-4A71VA - E1 , E2 , E3 , E4
16-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
No.
RoHS
Part numbers that are circled are not shown in the illustration.
Parts No.
1 G E12
2 G E12
G E12
3
G E12
G E12
G E12
G E12
4
G E12
G E12
G E12
5 G E12
6 G E12
7 G E12
G E12
8
G E12
G E12
9
G E12
10 G E12
11 G E12
12 G E12
13 G E12
14 G E12
15 G E12
851
938
939
C07
938
939
C06
C07
C18
C19
938
927
823
938
939
939
C18
938
938
938
127
737
735
501
301
440
440
450
450
450
450
450
450
444
374
375
307
307
490
490
308
309
337
382
382
385
Parts Name
Symbol
in Wiring
Diagram
PROPELLER
MF
OUTDOOR FAN MOTOR
POWER BOARD
POWER BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
NOISE FILTER P.C. BOARD
TB2~5
TERMINAL BLOCK
TB1
TERMINAL BLOCK
GAS PIPE TEMPERATURE THERMISTOR SET RT6A,B,C
GAS PIPE TEMPERATURE THERMISTOR SET RT6A,B,C,D
21S4
R.V. COIL
21S4
R.V. COIL
RT61,62,68
THERMISTOR SET
RT65
AMBIENT TEMPERATURE THERMISTOR
L
REACTOR
F801
FUSE
F911
FUSE
F64,NR64
FUSE&VARISTOR SET
Q'ty/unit
MXZ-3A54VA-
MXZ-4A71VA-
Remarks
E1
E2
E3
E4
E1
E2
E3
E4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 RC0J60-
1
Including heat sink and RT64
1 Including heat sink and RT64
1
1
1
1
1
1
1
1
3
1
1
1
3
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
4
1
1
4
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4 Indoor unit connecting
1 Power supply
1
1
1
1
1
1
1
DEFROST, DISCHARGE
OUTDOOR HEAT EXCHANGER
20A 600μH
T3.15AL250V
T1AL250V
T2AL250V
No.
RoHS
16-6. ACCESSORY
Parts No.
Parts Name
Q'ty/unit
Symbol
MXZ-4A71VAin Wiring MXZ-3A54VADiagram E1 E2 E3 E4 E1 E2 E3 E4
16 G E12 817 704 DRAIN SOCKET
17 G E12 444 705 DRAIN CAP
1
2
179
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Remarks
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E5 , E6 , E7
MXZ-4A71VA - E5 , E6 , E7
16-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
23
22
20
21
19
18
17
1
16
13
2
3
12
4
5
6 7 8 9
180
10
11
14
15
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E5 , E6 , E7
MXZ-4A71VA - E5 , E6 , E7
16-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
RoHS
Part numbers that are circled are not shown in the illustration.
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
Parts No.
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
E12
D36
817
939
D36
C18
F10
C34
851
939
851
938
851
939
851
938
939
D36
D37
D36
939
D36
D36
D36
D36
C18
819
939
939
939
938
939
938
C18
853
819
232
009
521
246
900
900
506
640
494
640
494
640
493
640
493
290
666
666
667
233
245
662
661
299
961
297
523
630
515
937
936
936
959
640
493
Parts Name
CABINET
HANDLE
GRILLE
SUB PANEL
COMPRESSOR
COMPRESSOR
COMPRESSOR RUBBER SET
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
BASE
UNION(GAS)
UNION(GAS)
UNION(LIQUID)
BACK PANEL
SERVICE PANEL
STOP VALVE (LIQUID) 3/8
STOP VALVE (GAS) 5/8
OIL SEPARATOR
4-WAY VALVE
TOP PANEL
REAR GUARD
OUTDOOR HEAT EXCHANGER
MOTOR SUPPORT
CAPILLARY TUBE
CAPILLARY TUBE
CAPILLARY TUBE
POWER RECEIVER
EXPANSION VALVE
LEV COIL
Symbol
in Wiring
Diagram
MC
MC
Q'ty/unit
MXZ-3A54VA-
MXZ-4A71VA-
E5
E6
E7
E5
E6
E7
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
1
3
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
1
1
1
8
3
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
8
3
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
8
3
1
1
1
1
LEV D
LEV C
LEV B
LEV A
LEV E
181
3
1
1
1
1
1
1
1
1
1
3
1
4
1
1
1
1
1
1
1
1
1
1
8
4
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
1
4
1
1
1
1
1
1
1
1
1
1
8
4
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
1
4
1
1
1
1
1
1
1
1
1
1
8
4
1
1
1
1
Remarks
SNB130FGBH1
SNB130FGBH1T
3RUBBERS SET
D room
D room
C room
C room
B room
B room
A room
A room
9.52
12.7
6.35
9.52
15.88
3.6
4.0
2.5
E
2.4 500
2.8 100
0.6 1000
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E5 , E6 , E7
MXZ-4A71VA - E5 , E6 , E7
16-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
11
10
9
8
1
2
3
4
5
6
16
16-9. ACCESSORY
15
182
7
RoHS PARTS LIST (RoHS compliant)
MXZ-3A54VA - E5 , E6 , E7
MXZ-4A71VA - E5 , E6 , E7
16-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
No.
RoHS
Part numbers that are circled are not shown in the illustration.
Parts No.
1 G E12 851
2 G E12 938
3 G E12 C07
G E12 D36
G E12 D87
G E12 F10
4
G E12 D37
G E12 D88
G E12 F11
5 G E12 D36
6 G E12 C92
7 G E12 D69
8 G E12 C18
9 G E12 938
10 G E12 938
11 G E12 938
12 G E12 784
13 G E12 250
14 G E12 977
501
301
440
450
450
450
450
450
450
444
375
374
490
308
309
337
382
382
385
Parts Name
Symbol
in Wiring
Diagram
PROPELLER
MF
OUTDOOR FAN MOTOR
POWER BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
NOISE FILTER P.C. BOARD
TB2~5
TERMINAL BLOCK
TB1
TERMINAL BLOCK
21S4
R.V. COIL
RT61,62,68
THERMISTOR SET
RT65
AMBIENT TEMPERATURE THERMISTOR
L
REACTOR
F801
FUSE
F65
FUSE
F64,NR64
FUSE&VARISTOR SET
Q'ty/unit
MXZ-3A54VA-
MXZ-4A71VA-
E5
E6
E7
E5
E6
E7
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Remarks
RC0J60Including heat sink and RT64
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
Indoor unit connecting
Power supply
DEFROST, DISCHARGE
OUTDOOR HEAT EXCHANGER
20A 600μH
T3.15AL250V
T6.3AL250V
T2AL250V
No.
RoHS
16-9. ACCESSORY
Parts No.
Parts Name
Q'ty/unit
Symbol
MXZ-4A71VAin Wiring MXZ-3A54VAE6
E7
E5
E6
E7
Diagram E5
1
2
15 G E12 817 704 DRAIN SOCKET
16 G E12 444 705 DRAIN CAP
183
1
2
1
2
1
2
1
2
1
2
Remarks
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E1
16-10. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
25 24 23
22
21
19 18
20
2
14
15
17
16
1
2
5
13
6
11
7 8 9 10
3
4
184
12
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E1
16-10. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
RoHS
Part numbers that are circled are not shown in the illustration.
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
Parts No.
M21
M21
M21
M21
T92
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
L2V
L2V
L2V
L2V
505
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
232
027
010
245
801
505
401
654
401
653
401
652
401
651
290
644
247
667
668
248
959
642
646
402
651
297
523
630
249
937
936
938
656
Parts Name
FRONT PANEL
HANDLE ASSEMBLY
GRILLE
SERVICE PANEL
COMPRESSOR
COMPRESSOR RUBBER SET
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
BASE ASSEMBLY
UNION
PIPE COVER
BALL VALVE (LIQUID) 3/8
BALL VALVE (GAS) 5/8
REAR PANEL
POWER RECEIVER
4-WAY VALVE
HIGH PRESSURE SWITCH
EXPANSION VALVE
LEV COIL
TOP PANEL
REAR GUARD
OUTDOOR HEAT EXCHANGER
SIDE PANEL
CAPILLARY TUBE
CAPILLARY TUBE
CAPILLARY TUBE
OIL SEPARATOR
Symbol
in Wiring
Diagram
MC
LEV D
LEV C
LEV B
LEV A
HPS
LEV E
185
Q'ty/unit
MXZ-4A80VA1
2
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
Remarks
E1
TNB220FMCH
3RUBBERS SET
D room
D room
C room
C room
B room
B room
A room
A room
12.7, 9.52, 6.35 SET
9.52
15.88
4.8 MPa (48.9 kg/cm2)
E
4.0
4.0
2.5
2.4 400
2.8 90
0.6 1000
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E1
16-11. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
12
11
10
9
8
7
1
16-12. ACCESSORY
2
3
4
5
16
186
6
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E1
16-11. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
No.
RoHS
Part numbers that are circled are not shown in the illustration.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
Parts No.
M21
M21
T2W
T2W
M21
T2W
T2W
T2W
M21
T2W
M21
M21
T2W
T2W
T2W
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
501
301
440
451
337
424
376
377
307
398
308
309
381
382
313
Parts Name
Symbol
in Wiring
Diagram
PROPELLER
MF
OUTDOOR FAN MOTOR
POWER BOARD
ELECTRONIC CONTROL P.C. BOARD
REACTOR
L
NOISE FILTER P.C. BOARD
TERMINAL BLOCK
TB2~5
TERMINAL BLOCK
TB1
GAS PIPE TEMPERATURE THERMISTOR RT6A,B,C,D
R.V. COIL
21S4
THERMISTOR SET
RT61,62,68
AMBIENT TEMPERATURE THERMISTOR RT65
FUSE
F801
FUSE
F911
FUSE&VARISTOR SET
F64,NR64
Q'ty/unit
MXZ-4A80VA-
E1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
Remarks
PM8H60Including heat sink and RT64
20A 600μH
Indoor unit connecting
Power supply
DEFROST, DISCHARGE,
OUTDOOR HEAT EXCHANGER
T3.15AL250V
T1AL250V
T2AL250V
No.
RoHS
16-12. ACCESSORY
Parts No.
Parts Name
Symbol
in Wiring
Diagram
16 G T2W L2V 704 DRAIN SOCKET ASSEMBLY
Q'ty/unit
MXZ-4A80VA1
187
E1
Remarks
DRAIN SOCKET
DRAIN CAP 2
1
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E2 MXZ-5A100VA - E1
16-13. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
22
21
23
20
24
19
17
18
15
16
14
2
1
2
5
6
13
7 8 9 10 11 12
3
4
188
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E2 MXZ-5A100VA - E1
16-13. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
RoHS
Part numbers that are circled are not shown in the illustration.
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
Parts No.
M21
M21
M21
M21
T92
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
M21
T2W
M21
M21
M21
M21
M21
M21
0A2
0A2
L2V
0A2
505
L2V
L2V
0A2
L2V
L2V
L2V
L2V
L2V
L2V
L2V
L2V
0A2
0A2
0A2
0A2
0A2
L2V
L2V
L2V
0A2
0A2
L2V
0A2
0A3
0A2
L2V
L2V
0A2
0A2
L2V
L2V
232
027
010
245
801
505
401
651
401
654
401
653
401
652
401
651
290
644
668
667
248
642
646
402
402
652
297
523
630
630
249
959
937
936
938
656
Parts Name
FRONT PANEL
HANDLE ASSEMBLY
GRILLE
SERVICE PANEL
COMPRESSOR
COMPRESSOR RUBBER SET
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
EXPANSION VALVE
LEV COIL
BASE ASSEMBLY
UNION
STOP VALVE (LIQUID) 3/8
STOP VALVE (GAS) 5/8
REAR PANEL
4-WAY VALVE
HIGH PRESSURE SWITCH
EXPANSION VALVE
EXPANSION VALVE
LEV COIL
TOP PANEL
REAR GUARD
OUTDOOR HEAT EXCHANGER
OUTDOOR HEAT EXCHANGER
SIDE PANEL
POWER RECEIVER
CAPILLARY TUBE
CAPILLARY TUBE
CAPILLARY TUBE
OIL SEPARATOR
Q'ty/unit
Symbol
in Wiring
MXZ-4A80VA- E2 MXZ-5A100VADiagram
MC
1
2
1
1
1
3
LEV E
LEV D
LEV C
LEV B
LEV A
HPS
LEV F
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
189
1
2
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
5
1
1
Remarks
E1
TNB220FMCH
3RUBBERS SET
E room
E room
D room
D room
C room
C room
B room
B room
A room
A room
12.7, 9.52, 6.35 SET
9.52
15.88
4.8 MPa (48.9 kg/cm2)
F
F
3.0
4.0
2.5
2.0 300
2.8 100
0.6 1000
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E2 MXZ-5A100VA - E1
16-14. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
11
10
9
8
7
1
16-15. ACCESSORY
2
3
15
190
4
5
6
RoHS PARTS LIST (RoHS compliant)
MXZ-4A80VA - E2 MXZ-5A100VA - E1
16-14. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
No.
RoHS
Part numbers that are circled are not shown in the illustration.
Parts No.
1 G M21 L2V
2 G M21 L2V
3 G M21 0A1
G T2W 0A3
4
G T2W 0A2
5 G M21 L2V
6 G M21 0A0
7 G T2W 0A2
8 G T2W L2V
9 G T2W L2V
10 G M21 L2V
11 G M21 0A2
12 G T2W L2V
13 G M21 0A2
14 G M21 T0A
501
301
440
451
451
337
424
376
377
398
308
309
381
313
313
Parts Name
Q'ty/unit
Symbol
in Wiring
MXZ-4A80VA- E2 MXZ-5A100VADiagram
PROPELLER
MF
OUTDOOR FAN MOTOR
POWER BOARD
ELECTRONIC CONTROL P.C. BOARD
ELECTRONIC CONTROL P.C. BOARD
REACTOR
L
NOISE FILTER P.C. BOARD
TERMINAL BLOCK
TB2~6
TERMINAL BLOCK
TB1
R.V. COIL
21S4
THERMISTOR SET
RT61,62,68
AMBIENT TEMPERATURE THERMISTOR RT65
FUSE
F801,931
FUSE&VARISTOR SET
F64,NR64
FUSE
F65
1
1
1
1
1
1
4
1
1
1
1
1
1
1
E1
1
1
1
Remarks
PM8H60Including heat sink and RT64
1
1
1
5
1
1
1
1
1
1
1
20A 600μH
Indoor unit connecting
Power supply
DEFROST, DISCHARGE,
OUTDOOR HEAT EXCHANGER
T3.15AL250V
T2AL250V
T6.3AL250V
No.
RoHS
16-15. ACCESSORY
Parts No.
Parts Name
Q'ty/unit
Symbol
in Wiring
MXZ-4A80VA- E2 MXZ-5A100VADiagram
15 G T2W L2V 704 DRAIN SOCKET ASSEMBLY
1
191
1
E1
Remarks
DRAIN SOCKET
DRAIN CAP 2
1
17
OPTIONAL PARTS
17-1. DIFFERENT-DIAMETER PIPE
Unit: mm (inch)
MXZ-3A54
MXZ-4A71
MXZ-4A80
MXZ-5A100
Model name
MAC-A454JP
For differentdiameter
pipes
MAC-A455JP
MAC-A456JP
PAC-493PI
PAC-SG76RJ-E
Connected pipes
diameter
9.52 —
(3/8)
12.7 —
(1/2)
12.7 —
(1/2)
6.35 —
(1/4)
9.52 —
(3/8)
12.7
(1/2)
9.52
(3/8)
15.88
(5/8)
9.52
(3/8)
15.88
(5/8)
Length
A
Length
B
9.52
(3/8)
12.7
(1/2)
12.7
(1/2)
6.35
(1/4)
9.52
(3/8)
12.7
(1/2)
9.52
(3/8)
15.88
(5/8)
9.52
(3/8)
15.88
(5/8)
Length
C
A
69
65
B
C
66.5
60.5
101.5
17-2. OUTLET GUIDE
Changes air discharge direction.
48
15.7
Z-Z
450.8
42.6
10 x 48 (=480)
51H-855
79
MAC-855SG
327
506-889
537.2
MAC-889SG
Z
103.1
MXZ-4A80
MXZ-5A100
Model name Model code
7
524
7
13.7
52.
5°
Punched hole
4- 6
538
Applied unit
MXZ-2A30
MXZ-2A40
MXZ-2A52
MXZ-3A54
MXZ-4A71
Z
71.6
MAC-889SG
109.4
51.8
29.2
150
5- 6
Punched hole
5- 6
Punched hole
29.2
386
534
6.4
832
760.8
416
6.4
610.4
534
386
MAC-855SG
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Copyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD
Distributed in Dec. 2008. No.OB377 REVISED EDITION-H 6
Distributed in Sep. 2008. No.OB377 REVISED EDITION-G 6
Distributed in Dec. 2007. No.OB377 REVISED EDITION-F 8
Distributed in Aug. 2007. No.OB377 REVISED EDITION-E 8
Distributed in May 2007. No.OB377 REVISED EDITION-D 8
Distributed in Feb. 2007. No.OB377 REVISED EDITION-C 8
Distributed in Oct. 2006. No.OB377 REVISED EDITION-B 8
Distributed in Dec. 2005. No.OB377 REVISED EDITION-A 8
Distributed in Feb. 2005. No.OB377 8
Made in Japan
New publication, effective Dec. 2008
Specifications subject to change without notice.