Download Mitsubishi MXZ-2A52VA Service manual
Transcript
Revision H: • Indoor units combinations for 42 class have been added. • MXZ-3A54VA- E7 and MXZ-4A71VA- E7 have been added. SPLIT-TYPE AIR CONDITIONERS Please void OB377 REVISED EDITION-G. OUTDOOR UNIT SERVICE MANUAL Models MXZ-2A30VA MXZ-2A30VA MXZ-2A40VA MXZ-2A40VA MXZ-2A52VA MXZ-2A52VA MXZ-3A54VA MXZ-3A54VA MXZ-3A54VA MXZ-3A54VA MXZ-3A54VA MXZ-3A54VA MXZ-3A54VA MXZ-4A71VA - HFC utilized No. OB377 REVISED EDITION-H R410A MXZ-4A71VA - E2 MXZ-4A71VA - E3 MXZ-4A71VA - E4 MXZ-4A71VA - E5 MXZ-4A71VA - E6 MXZ-4A71VA - E7 MXZ-4A80VA - E1 MXZ-4A80VA - E2 MXZ-5A100VA - E1 E1 E2 E1 E2 E1 E2 E1 E2 E3 Indoor unit service manual MSZ-FA•VA Series (OB371) MSZ-GA•VA Series (OB378, OB388) MSZ-CB•VA Series (OB441) MSZ-GC•VA Series (OBH468) MSZ-GE•VA Series (OBH515) MSZ-FD•VA Series (OBH488) E4 E5 E6 E7 E1 CONTENTS MXZ-4A80VA- E1 NOTE: • RoHS compliant products have <G> mark on the spec name plate. For servicing of RoHS compliant products, refer to the RoHS Parts List. 1. TECHNICAL CHANGES ··································· 2 2. PART NAMES AND FUNCTIONS ····················· 8 3. INDOOR/OUTDOOR CORRESPONDENCE TABLE ························ 10 4. INDOOR UNITS COMBINATION ···················· 14 5. SPECIFICATION ·············································· 61 6. NOISE CRITERIA CURVES ···························· 66 7. OUTLINES AND DIMENSIONS ······················ 68 8. WIRING DIAGRAM·········································· 75 9. REFRIGERANT SYSTEM DIAGRAM ············· 87 10. PERFORMANCE CURVES ····························· 97 11. ACTUATOR CONTROL ··································115 12. SERVICE FUNCTIONS···································116 13. TROUBLESHOOTING ··································· 120 14. DISASSEMBLY INSTRUCTIONS ·················· 145 15. PARTS LIST··················································· 160 16. RoHS PARTS LIST ········································ 172 17. OPTIONAL PARTS ······················ BACK COVER Revision A : • MXZ-3A54VA- E1 and MXZ-4A71VA- E2 have been added. Quick clean kit has been removed. (Refer to 2.) • MXZ-2A40VA- E1 and MXZ-2A52VA- E2 have been added. Revision B : • MXZ-2A30VA- E1 and MXZ-2A40VA• “Check of HPS” has been corrected. • RoHS PARTS LIST has been added. E2 have been added. Revision C : • MXZ-2A52VA- E2 , MXZ-3A54VA- E3 , MXZ-4A71VA- E3 , MXZ-4A80VA- E2 and MXZ-5A100VA- Revision D: • MXZ-3A54VA- E4 , and MXZ-4A71VA- E4 have been added. • The content of pre-heat control (12-3) has been corrected. • 5. SPECIFICATION has been corrected. Revision E: • MXZ-2A30VA- E1 has been added. • 4. INDOOR UNITS COMBINATION of MXZ-5A100VA- E2 has been changed. Revision F: • MXZ-3A54VA- E5 and MXZ-4A71VA- E5 have been added. E6 and MXZ-4A71VA- E6 have been added. Revision G: • MXZ-3A54VA- Revision H: • Indoor units combinations for 42 class have been added. • MXZ-3A54VA- E7 and MXZ-4A71VA- E7 have been added. 1 TECHNICAL CHANGES MXZ-A26WV - E1 MXZ-3A54VA - E1 1. Indication of capacity has been changed. (BTU kW) 2. Capacity specification has been changed. (Cooling capacity 7.1kW 5.4kW) 3. Dimensions of unit have been changed. (W900 H900 D320 W840 H710 D330) 4. Combinations of connectable indoor units have been changed. 5. Capacity class of connectable indoor units has been changed. 6. Communication system has been changed. 7. Power supply way has been changed (change to supply to outdoor unit). 8. Compressor has been changed. (TNB220FMCH SNB130FLDH1) 9. High-pressure switch has been removed. 10.Outdoor fan motor has been changed. (PM8H60-UA RC0J60-AA) 11.Evaporation temperature thermistor has been removed. 12.Ambient temperature thermistor has been added. 13.New dip switch has been added to the controller board for "Locking the operation "mode and "Lowering the operating noise "mode. 14.A Quick Clean Kit has been added. MXZ-A32WV - E1 MXZ-4A71VA - E1 1. Indication of capacity has been changed. (BTU kW) 2. Capacity specification has been changed. (Cooling capacity 8.0kW 7.1kW) 3. Dimensions of unit have been changed. (W900 H900 D320 W840 H710 D330) 4. Combinations of connectable indoor units have been changed. 5. Capacity class of connectable indoor units has been changed. 6. Communication system has been changed. 7. Power supply way has been changed (change to supply to outdoor unit). 8. Compressor has been changed. (TNB220FMCH SNB130FLDH1) 9. High-pressure switch has been removed. 10. Outdoor fan motor has been changed. (PM8H60-UA RC0J60-AA) 11. Evaporation temperature thermistor has been removed. 12. Ambient temperature thermistor has been added. 13. New dip switch has been added to the controller board for "Locking the operation "mode and "Lowering the operating noise "mode. 14. A Quick Clean Kit has been added. 2 E1 have been added. MXZ-A32WV - E1 MXZ-4A80VA - E1 1. Indication of capacity has been changed. (BTU kW) 2. Communication system has been changed. 3. Power supply way has been changed (change to supply to outdoor unit). 4. Evaporation temperature thermistor has been removed. 5. Ambient temperature thermistor has been added. 6. New dip switch has been added to the controller board for "Locking the operation "mode and "Lowering the operating noise "mode. 7. A Quick Clean Kit has been added. MXZ-A14WV - E2 MXZ-2A40VA - E1 1. Indication of capacity has been changed. (BTU kW) 2. Dimensions of unit have been changed. (W840 H640 D330 W800 H550 3. Communication system has been changed. 4. Power supply way has been changed (change to supply to outdoor unit). 5. Compressor has been changed. (SNV092FJYH SNB130FKCH) 6. Outdoor fan motor has been changed. (RA6V49 RC0J50-CF) 7. Evaporation temperature thermistor has been removed. 8. Gas pipe temperature thermistor has been removed. 9. Ambient temperature thermistor has been added. MXZ-A18WV - E2 MXZ-2A52VA - E1 1. Indication of capacity has been changed. (BTU kW) 2. Cooling capacity specification has been changed. (5.4 kW 5.2 kW) 3. Heating capacity specification has been changed. (6.6 kW 6.4 kW) 4. Dimensions of unit have been changed. (W840 H640 D330 W800 H550 5. Communication system has been changed. 6. Power supply way has been changed (change to supply to outdoor unit). 7. Compressor has been changed. (SNV092FJYH SNB130FKCH) 8. Outdoor fan motor has been changed. (RA6V49 RC0J50-CF) 9. Evaporation temperature thermistor has been removed. 10. Gas pipe temperature thermistor has been removed. 11. Ambient temperature thermistor has been added. MXZ-3A54VA - E1 MXZ-4A71VA - E1 MXZ-3A54VA - E2 MXZ-4A71VA - E2 1. Quick clean kit has been removed. MXZ-2A30VA - E1 1. New model MXZ-2A40VA - E1 MXZ-2A40VA - E2 1. Compressor has been changed. (SNB130FKCH 2. Outdoor heat exchanger has been changed. MXZ-2A52VA - E1 D285) KNB092FEDH) MXZ-2A52VA - E2 1. Compressor has been changed. (SNB130FKCH 2. Inverter P.C. board has been changed. SNB130FKMH) 3 D285) MXZ-3A54VA - E2 MXZ-3A54VA - E3 1. Compressor has been changed. (SNB130FLDH1 2. Electronic control P.C. board has been changed. MXZ-4A71VA - E2 MXZ-4A71VA - E3 1. Compressor has been changed. (SNB130FLDH1 2. Electronic control P.C. board has been changed. MXZ-4A80VA - E1 SNB130FLEH1) SNB130FLEH1) MXZ-4A80VA - E2 1. Ball valve has been changed to stop valve. 2. Gas pipe temperature thermistor has been removed. 3. Pre-heat control has been added. 4. Auto line correcting function has been added. 5. Noise filter P.C. board has been changed. 6. Electronic control P.C. board has been changed. 7. Weight has been changed. (70kg 67kg) MXZ-5A100VA - E1 1. New model MXZ-3A54VA - E3 1. 2. 3. 4. 5. MXZ-4A71VA - E3 1. 2. 3. 4. 5. MXZ-3A54VA - E4 Compressor has been changed. (SNB130FLEH1 SNB130FGBH1) Electronic control P.C. board has been changed. Gas pipe temperature thermistor has been removed. Pre-heat control has been added. Power board has been changed. MXZ-4A71VA - E4 Compressor has been changed. (SNB130FLEH1 SNB130FGBH1) Electronic control P.C. board has been changed. Gas pipe temperature thermistor has been removed. Pre-heat control has been added. Power board has been changed. MXZ-2A30VA - E1 MXZ-2A30VA - E2 1. Compressor has been changed. (KNB092FEDH 2. Inverter P.C. board has been changed. MXZ-3A54VA - E4 1. 2. 3. 4. MXZ-3A54VA - E5 Electronic control P.C. board has been changed. Noise filter P.C. board has been changed. Ball valve has been changed to stop valve. Sub panel has been added. MXZ-4A71VA - E4 1. 2. 3. 4. KNB073FGDH) MXZ-4A71VA - E5 Electronic control P.C. board has been changed. Noise filter P.C. board has been changed. Ball valve has been changed to stop valve. Sub panel has been added. MXZ-3A54VA - E5 MXZ-4A71VA - E5 MXZ-3A54VA - E6 MXZ-4A71VA - E6 1. Electronic control P.C. board has been changed. MXZ-3A54VA - E6 MXZ-4A71VA - E6 MXZ-3A54VA - E7 MXZ-4A71VA - E7 1. Electronic control P.C. board has been changed. 2. Compressor has been changed. (SNB130FGBH1 SNB130FGBH1T) 4 INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT • This room air conditioner adopts HFC refrigerant (R410A) which never destroys the ozone layer. • Pay particular attention to the following points, though the basic installation procedure is same as that for R22 air conditioners. As R410A has working pressure approximately 1.6 times as high as that of R22, some special tools and piping parts/ materials are required. Refer to the table below. Take sufficient care not to allow water and other contaminations to enter the R410A refrigerant during storage and installation, since it is more susceptible to contaminations than R22. For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R410A. (Refer to 2. Refrigerant piping.) Composition change may occur in R410A since it is a mixed refrigerant. When charging, charge liquid refrigerant to prevent composition change. New refrigerant Previous refrigerant R410A R22 Refrigerant Composition (Ratio) HFC-32: HFC-125 (50%:50%) R22 (100%) Refrigerant handling Pseudo-azeotropic refrigerant Single refrigerant Not included Included A1/A1 A1 72.6 86.5 Boiling point (°C) -51.4 -40.8 Steam pressure [25°C](Mpa) 1.557 0.94 Chlorine Refrigerant Safety group (ASHRAE) Molecular weight 3 Saturated steam density [25°C](Kg/m ) 64 44.4 Non combustible Non combustible ODP 1 0 0.055 GWP 2 1730 1700 From liquid phase in cylinder Gas phase Possible Possible Kind Incompatible oil Compatible oil Color Non Light yellow Non Non Combustibility Refrigerant charge method oil Refrigeration Additional charge on leakage Smell 1 :Ozone Depletion Potential 2 :Global Warming Potential : based on CFC-11 : based on CO2 5 Compressor New Specification Current Specification The incompatible refrigeration oil easily separates from Since refrigerant and refrigeration oil are compatible, refrigerant and is in the upper layer inside the suction muffler. refrigeration oil goes back to the compressor through the Raising position of the oil back hole enables to back the lower position oil back hole. refrigeration oil of the upper layer to flow back to the compressor. Suction muffler Suction muffler Oil back hole Compressor Compressor Refrigeration oil Oil back hole Refrigerant Refrigeration oil /Refrigerant NOTE : The unit of pressure has been changed to MPa on the international system of units (SI unit system). The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/cm2 [Gauge]) Conversion chart of refrigerant temperature and pressure (MPa [Gauge]) 4.0 Saturated liquid pressure 3.5 R410A 3.0 R22 2.5 2.0 1.5 NOTE : The unit of pressure has been changed to MPa on the international system of units (SI unit system). 1.0 0.5 The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/cm2 [Gauge]) 0.0 -0.5 -30 -20 -10 0 10 20 30 40 50 60 (°C) 1. Tools dedicated for the air conditioner with R410A refrigerant The following tools are required for R410A refrigerant. Some R22 tools can be substituted for R410A tools. The diameter of the service port on the stop valve in outdoor unit has been changed to prevent any other refrigerant from being charged into the unit. Cap size has been changed from 7/16 UNF with 20 threads to 1/2 UNF with 20 threads. R410A tools Gauge manifold No Charge hose No R410A has high pressures beyond the measurement range of existing gauges. Port diameters have been changed to prevent any other refrigerant from being charged into the unit. No Hose material and cap size have been changed to improve the pressure resistance. Dedicated for HFC refrigerant. Yes 6.35 mm and 9.52 mm Gas leak detector Torque wrench Description Can R22 tools be used? No 12.7 mm and 15.88 mm Flare tool Yes Clamp bar hole has been enlarged to reinforce the spring strength in the tool. Flare gauge Vacuum pump adapter Electronic scale for refrigerant charging New Provided for flaring work (to be used with R22 flare tool). Provided to prevent the back flow of oil. This adapter enables you to use vacuum pumps. It is difficult to measure R410A with a charging cylinder because the refrigerant bubbles due to high pressure and high-speed vaporization New New No: Not Substitutable for R410A Yes: Substitutable for R410A 6 2. Refrigerant piping Specifications Use the copper or copper-alloy seamless pipe for refrigerant that meet the following specifications. Outside diameter mm Insulation material Wall thickness 6.35 0.8 mm 9.52 0.8 mm Heat resisting foam plastic 12.7 0.8 mm Specific gravity 0.045 Thickness 8 mm 15.88 1.0 mm Flaring work and flare nut Flaring work for R410A pipe differs from that for R22 pipe. For details of flaring work, refer to Installation manual “FLARING WORK”. Dimension of flare nut Pipe diameter mm R410A R22 6.35 17 17 9.52 22 22 12.7 26 24 15.88 29 27 3. Refrigeration oil Apply the special refrigeration oil (accessories: packed with indoor unit) to the flare and the union seat surfaces. 4. Air purge • Do not discharge the refrigerant into the atmosphere. Take care not to discharge refrigerant into the atmosphere during installation, reinstallation, or repairs to the refrigerant circuit. • Use the vacuum pump for air purging for the purpose of environmental protection. 5. Additional charge For additional charging, charge the refrigerant from liquid phase of the gas cylinder. If the refrigerant is charged from the gas phase, composition change may occur in the refrigerant inside the cylinder and the outdoor unit. In this case, ability of the refrigeration cycle decreases or normal operation can be impossible. However, charging the liquid refrigerant all at once may cause the compressor to be locked. Thus, charge the refrigerant slowly. Union Stop valve Indoor unit Liquid pipe Gas pipe Refrigerant gas cylinder operating valve Outdoor unit Service port Gauge manifold valve (for R410A) Charge hose (for R410A) Refrigerant gas cylinder for R410A with siphon Refrigerant (liquid) Electronic scale for refrigerant charging 7 2 PART NAMES AND FUNCTIONS MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA- E1 , MXZ-4A71VA- E1 , , E2 , E2 , E3 , E3 E4 E4 Air inlet (Back and side) Air inlet (Back and side) Piping Drain hose Air outlet Air outlet Drain outlet Drain outlet MXZ-3A54VA- E5 , MXZ-4A71VA- E5 , E6 E6 , , E7 E7 Air inlet (Back and side) Air outlet Drain outlet 8 MXZ-4A80VA- MXZ-4A80VA- E2 MXZ-5A100VA E1 Air inlet (Back and side) Air inlet (Back and side) Air outlet Air outlet Drain outlet Drain outlet ACCESSORIES MXZ-3A54VA - E2 MXZ-4A71VA - E2 MXZ-4A80VA MXZ-5A100VA MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA - E1 MXZ-4A71VA - E1 Drain socket 1 1 1 Drain cap - 2 2 Quick Clean kit - 1 - 9 , E3 , E4 , E5 , E6 , E7 , E3 , E4 , E5 , E6 , E7 3 INDOOR/OUTDOOR CORRESPONDENCE TABLE MXZ-2A30VA MXZ-4A71VA MXZ-4A71VA 22+22 22+25 25+25 22+22 22+25 22+35 22+42 22+50 22+60 25+25 25+35 25+42 25+50 25+60 35+35 35+42 35+50 35+60 42+42 42+50 42+60 50+50 50+60 60+60 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+35+35 22+35+42 22+35+50 22+35+60 22+42+42 22+42+50 22+42+60 22+50+50 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+35+35 25+35+42 25+35+50 25+35+60 25+42+42 25+42+50 25+50+50 35+35+35 35+35+42 35+35+50 35+42+42 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+35+35 22+22+35+42 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+35+35 22+25+35+42 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+35+35 Indoor units combination MXZ-2A40VA 22+22 22+25 22+35 25+25 25+35 22+22 22+25 22+35 25+25 25+35 35+35 Indoor units combination MXZ-3A54VA 22+22 22+25 22+35 22+42 22+50 25+25 25+35 25+42 25+50 35+35 35+42 35+50 42+42 42+50 50+50 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+25+25 22+25+35 22+25+42 22+25+50 22+35+35 22+35+42 25+25+25 25+25+35 25+25+42 25+25+50 25+35+35 Indoor units combination Indoor units combination MXZ-2A52VA Indoor units combination Indoor units combination There is no combination other than this table. 10 MXZ-4A80VA MXZ-4A80VA 22+22 22+25 22+35 22+42 22+50 22+60 22+71 25+25 25+35 25+42 25+50 25+60 25+71 35+35 35+42 35+50 35+60 35+71 42+42 42+50 42+60 42+71 50+50 50+60 50+71 60+60 60+71 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+25+71 22+35+35 22+35+42 22+35+50 22+35+60 22+35+71 22+42+42 22+42+50 22+42+60 22+42+71 22+50+50 22+50+60 22+50+71 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+25+71 25+35+35 25+35+42 25+35+50 25+35+60 25+35+71 25+42+42 25+42+50 25+42+60 25+42+71 25+50+50 25+50+60 35+35+35 35+35+42 35+35+50 35+35+60 35+35+71 35+42+42 35+42+50 35+42+60 35+50+50 35+50+60 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+42 22+22+35+50 22+22+35+60 22+22+42+42 22+22+42+50 22+22+50+50 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+25+60 22+25+35+35 22+25+35+42 22+25+35+50 22+25+35+60 22+35+35+35 22+35+35+42 22+35+35+50 22+35+42+42 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+25+60 25+25+35+35 25+25+35+42 25+25+35+50 25+35+35+35 25+35+35+42 35+35+35+35 Indoor units combination MXZ-4A80VA Indoor units combination Indoor units combination There is no combination other than this table. 11 MXZ-5A100VA MXZ-5A100VA 22+60+60 22+60+71 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+25+71 25+35+35 25+35+42 25+35+50 25+35+60 25+35+71 25+42+42 25+42+50 25+42+60 25+42+71 25+50+50 25+50+60 25+50+71 25+60+60 25+60+71 35+35+35 35+35+42 35+35+50 35+35+60 35+35+71 35+42+42 35+42+50 35+42+60 35+42+71 35+50+50 35+50+60 35+50+71 35+60+60 35+60+71 42+42+42 42+42+50 42+42+60 42+42+71 42+50+50 42+50+60 42+50+71 42+60+60 50+50+50 50+50+60 50+50+71 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+42 22+22+35+50 22+22+35+60 22+22+35+71 22+22+42+42 22+22+42+50 22+22+42+60 22+22+42+71 22+22+50+50 22+22+50+60 22+22+50+71 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+25+60 22+25+25+71 22+25+35+35 22+25+35+42 22+25+35+50 22+25+35+60 22+25+35+71 22+25+42+42 22+25+42+50 22+25+42+60 22+25+42+71 22+25+50+50 22+25+50+60 22+25+50+71 22+35+35+35 22+35+35+42 22+35+35+50 22+35+35+60 22+35+35+71 22+35+42+42 22+35+42+50 22+35+42+60 22+35+42+71 22+35+50+50 22+35+50+60 22+42+42+42 22+42+42+50 22+42+42+60 22+42+50+50 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+25+60 25+25+25+71 25+25+35+35 25+25+35+42 25+25+35+50 25+25+35+60 25+25+35+71 25+25+42+42 25+25+42+50 25+25+42+60 25+25+42+71 25+25+50+50 25+25+50+60 25+25+50+71 25+35+35+35 25+35+35+42 25+35+35+50 25+35+35+60 25+35+35+71 25+35+42+42 25+35+42+50 25+35+42+60 25+42+42+42 25+42+42+50 25+42+42+60 25+42+50+50 35+35+35+35 35+35+35+42 35+35+35+50 35+35+35+60 35+35+42+42 35+35+42+50 35+42+42+42 35+42+42+50 42+42+42+42 22+22+22+22+22 22+22+22+22+25 22+22+22+22+35 22+22+22+22+42 22+22+22+22+50 22+22+22+22+60 22+22+22+22+71 22+22+22+25+25 22+22+22+25+35 22+22+22+25+42 22+22+22+25+50 22+22+22+25+60 22+22+22+25+71 22+22+22+35+35 22+22+22+35+42 12 Indoor units combination MXZ-5A100VA 22+22 22+25 22+35 22+42 22+50 22+60 22+71 25+25 25+35 25+42 25+50 25+60 25+71 35+35 35+42 35+50 35+60 35+71 42+42 42+50 42+60 42+71 50+50 50+60 50+71 60+60 60+71 71+71 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+25+71 22+35+35 22+35+42 22+35+50 22+35+60 22+35+71 22+42+42 22+42+50 22+42+60 22+42+71 22+50+50 22+50+60 22+50+71 Indoor units combination MXZ-5A100VA Indoor units combination Indoor units combination There is no combination other than this table. There is no combination other than this table. Indoor units combination MXZ-5A100VA MXZ-5A100VA Indoor units combination 22+22+22+35+50 22+22+22+35+60 22+22+22+35+71 22+22+22+42+42 22+22+22+42+50 22+22+22+42+60 22+22+25+25+25 22+22+25+25+35 22+22+25+25+42 22+22+25+25+50 22+22+25+25+60 22+22+25+25+71 22+22+25+35+35 22+22+25+35+42 22+22+25+35+50 22+22+25+35+60 22+22+25+42+42 22+22+25+42+50 22+22+25+42+60 22+22+35+35+35 22+22+35+35+42 22+22+35+35+50 22+22+35+42+42 22+22+35+42+50 22+22+42+42+42 22+25+25+25+25 22+25+25+25+35 22+25+25+25+42 22+25+25+25+50 22+25+25+25+60 22+25+25+25+71 22+25+25+35+35 22+25+25+35+42 22+25+25+35+50 22+25+25+35+60 22+25+25+42+42 22+25+25+42+50 22+25+35+35+35 22+25+35+35+42 22+25+35+35+50 22+25+35+42+42 22+35+35+35+35 22+35+35+35+42 25+25+25+25+25 25+25+25+25+35 25+25+25+25+42 25+25+25+25+50 25+25+25+25+60 25+25+25+25+71 25+25+25+35+35 25+25+25+35+42 25+25+25+35+50 25+25+25+35+60 25+25+25+42+42 25+25+25+42+50 25+25+35+35+35 25+25+35+35+42 25+25+35+35+50 25+25+35+42+42 13 4 INDOOR UNITS COMBINATION MXZ-2A30VA Cooling capacity (kW) Indoor units combination Unit A Unit B 22 2.20 – 25 2.50 – 22+22 1.40 1.40 22+25 1.40 1.50 25+25 1.50 1.50 Total 2.2 (0.9 - 3.0) 2.5 (0.9 - 3.3) 2.8 ( 1.1 - 3.8) 2.9 (1.1 - 3.9) 3.0 (1.1 - 4.0) Heating capacity (kW) Indoor units combination Unit A Unit B 22 3.30 – 25 3.60 – 22+22 1.90 1.90 22+25 1.90 2.00 25+25 2.00 2.00 Total 3.3 (0.9 - 4.0) 3.6 (0.9 - 4.5) 3.8 (1.0 - 4.3) 3.9 (1.0 - 4.4) 4.0 (1.0 - 4.5) 14 NOTE: Electrical data is for outdoor unit only. Outdoor unit Power Current power consumption factor (A) (kW) (%) 0.430 2.08 90 (0.120 - 0.620) 0.490 2.37 90 (0.120 - 0.690) 0.540 2.61 90 (0.250 - 0.970) 0.565 2.73 90 (0.250 - 1.020) 0.595 2.87 90 (0.250 - 1.070) NOTE: Electrical data is for outdoor unit only. Outdoor unit Power Current power consumption factor (A) (kW) (%) 0.670 3.24 90 (0.110 - 0.910) 0.730 3.53 90 (0.110 - 1.050) 0.705 3.41 90 (0.200 - 0.770) 0.725 3.50 90 ( 0.200 - 0.795) 0.745 3.60 90 (0.200 - 0.810) MXZ-2A40VA Cooling capacity (kW) Indoor units combination Unit A Unit B 22 2.20 – 25 2.50 – 35 3.50 – 22+22 1.90 1.90 22+25 1.83 2.07 22+35 1.51 2.39 25+25 1.95 1.95 25+35 1.67 2.33 Total 2.2 (0.9 - 3.0) 2.5 (0.9 - 3.3) 3.5 (0.9 - 4.0) 3.8 ( 1.1 - 4.3) 3.9 (1.1 - 4.3) 3.9 (1.1 - 4.4) 3.9 (1.1 - 4.4) 4.0 (1.1 - 4.5) Heating capacity (kW) Indoor units combination Unit A Unit B 22 3.30 – 25 3.60 – 35 4.00 – 22+22 2.20 2.20 22+25 2.06 2.34 22+35 1.70 2.70 25+25 2.20 2.20 25+35 1.85 2.65 Total 3.3 (0.9 - 4.0) 3.6 (0.9 - 4.5) 4.0 (0.9 - 4.8) 4.4 (1.0 - 4.8) 4.4 (1.0 - 4.8) 4.4 (1.0 - 4.9) 4.4 (1.0 - 4.9) 4.5 (1.0 - 5.0) 15 NOTE: Electrical data is for outdoor unit only. Outdoor unit Power Current power consumption factor (A) (kW) (%) 0.430 2.08 90 (0.120 - 0.620) 0.490 2.37 90 (0.120 - 0.690) 0.730 3.53 90 (0.120 - 0.900) 0.830 3.80 95 (0.250 - 1.110) 0.970 4.44 95 (0.250 - 1.110) 0.970 4.44 95 (0.250 - 1.130) 0.970 4.44 95 (0.250 - 1.130) 1.045 4.78 95 (0.250 - 1.170) NOTE: Electrical data is for outdoor unit only. Outdoor unit Power Current power consumption factor (A) (kW) (%) 0.670 90 3.24 (0.110 - 0.910) 0.730 3.53 90 (0.110 - 1.050) 0.870 4.20 90 (0.110 - 1.150) 0.910 4.16 95 (0.200 - 1.010) 0.910 4.16 95 ( 0.200 - 1.010) 0.910 4.16 95 (0.200 - 1.030) 0.910 4.16 95 (0.200 - 1.030) 0.945 4.32 95 (0.200 - 1.050) MXZ-2A52VA Cooling capacity (kW) Indoor units combination Unit A Unit B 22 2.20 – 25 2.50 – 35 3.50 – 22+22 2.20 2.20 22+25 2.20 2.50 22+35 1.93 3.07 25+25 2.50 2.50 25+35 2.13 2.97 35+35 2.60 2.60 Total 2.2 (0.9 - 3.0) 2.5 (0.9 - 3.3) 3.5 (0.9 - 4.0) 4.4 (1.1 - 5.3) 4.7 (1.1 - 5.4) 5.0 (1.1 - 5.6) 5.0 (1.1 - 5.6) 5.1 (1.1 - 5.8) 5.2 (1.1 - 6.0) Heating capacity (kW) Indoor units combination Unit A Unit B 22 3.30 – 25 3.60 – 35 4.00 – 22+22 3.05 3.05 22+25 2.90 3.30 22+35 2.43 3.87 25+25 3.15 3.15 25+35 2.63 3.67 35+35 3.20 3.20 Total 3.3 ( 0.9 - 4.0) 3.6 (0.9 - 4.5) 4.0 (0.9 - 4.8) 6.1 (1.0 - 6.7) 6.2 (1.0 - 6.8) 6.3 (1.0 - 7.0) 6.3 (1.0 - 7.0) 6.3 (1.0 - 7.1) 6.4 (1.0 - 7.2) 16 NOTE: Electrical data is for outdoor unit only. Outdoor unit Power Current power consumption factor (A) (kW) (%) 0.430 2.08 90 (0.120 - 0.620) 0.490 2.37 90 (0.120 - 0.690) 0.730 3.53 90 (0.120 - 0.900) 1.130 96 5.12 (0.250-1.510) 1.250 96 5.66 (0.250 - 1.560) 1.400 6.28 97 (0.250 - 1.650) 1.400 6.28 97 (0.250 - 1.650) 1.450 6.50 97 (0.250 - 1.740) 1.505 97 6.75 (0.250 - 1.830) NOTE: Electrical data is for outdoor unit only. Outdoor unit Power Current power consumption factor (A) (kW) (%) 0.670 90 3.24 (0.110 - 0.910) 0.730 3.53 90 (0.110 - 1.050) 0.870 4.20 90 (0.110 - 1.150) 1.550 97 6.95 (0.200 - 1.730) 1.600 97 7.17 (0.200 - 1.750) 1.650 7.40 97 (0.200 - 1.790) 1.650 7.40 97 (0.200 - 1.790) 1.650 7.40 97 (0.200 - 1.820) 1.705 7.64 97 (0.200 - 1.840) MXZ-3A54VA Indoor units combination 22 25 35 42 50 22+22 22+25 22+35 22+42 22+50 25+25 25+35 25+42 25+50 35+35 35+42 35+50 42+42 42+50 50+50 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+25+25 NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Unit A Unit B Unit C 2.2 - - Total ( 1.4 2.5 - - 3.5 - - ( 1.4 ( 1.5 4.2 - ( 1.6 5.0 - ( 1.6 2.2 2.2 ( 2.0 2.2 2.5 ( 2.0 2.08 3.32 ( 2.0 1.86 3.54 ( 2.0 1.65 3.75 - 2.5 2.5 - ( 2.0 ( 2.0 2.25 3.15 ( 2.0 2.01 3.39 ( 2.0 1.8 3.6 ( 2.0 2.7 2.7 ( 2.0 2.4 3.0 ( 2.0 2.22 3.18 ( 2.0 2.7 2.7 - 2.47 2.93 - ( 2.0 ( 2.1 2.7 2.7 ( 2.1 1.8 1.8 1.8 ( 2.9 1.72 1.72 1.96 ( 2.9 1.5 1.5 2.4 ( 2.9 1.38 1.38 2.64 ( 2.9 1.26 1.26 2.88 ( 2.9 1.64 1.88 1.88 ( 2.9 2.2 2.5 3.5 4.2 5.0 4.4 4.7 5.4 5.4 5.4 5.0 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 - 3.0 ) ( 3.3 ) ( 4.3 ) ( 5.0 ) ( 5.6 ) ( 5.4 ) ( 5.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.0 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 17 Outdoor unit power consumption (kW) 0.590 0.420 - 0.740 0.660 0.420 - 0.830 0.950 0.430 - 1.180 1.220 0.450 - 1.420 1.500 0.480 - 1.660 1.180 0.540 - 1.450 1.300 0.540 - 1.630 1.600 0.540 - 2.550 1.590 0.540 - 2.490 1.580 0.550 - 2.440 1.420 0.540 - 1.750 1.600 0.540 - 2.550 1.590 0.540 - 2.490 1.580 0.550 - 2.440 1.600 0.540 - 2.550 1.560 0.540 - 2.490 1.530 0.550 - 2.440 1.530 0.550 - 2.440 1.540 0.550 - 2.390 1.550 0.560 - 2.340 1.295 0.670 - 1.770 1.295 0.670 - 1.770 1.295 0.670 - 1.770 1.280 0.670 - 1.780 1.265 0.680 - 1.790 1.295 0.670 - 1.770 2.59 Power factor (%) 99 2.90 99 4.17 99 5.36 99 6.59 99 5.18 99 5.71 99 7.03 99 6.98 99 6.94 99 6.24 99 7.03 99 6.98 99 6.94 99 7.03 99 6.85 99 6.72 99 6.72 99 6.76 99 6.81 99 5.69 99 5.69 99 5.69 99 5.62 99 5.56 99 5.69 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) MXZ-3A54VA Indoor units combination 22+25+35 22+25+42 22+25+50 22+35+35 22+35+42 25+25+25 25+25+35 25+25+42 25+25+50 25+35+35 NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Unit A Unit B Unit C 1.45 1.65 2.3 Total ( 2.9 1.33 1.52 2.55 1.23 1.39 2.78 ( 2.9 ( 2.9 1.3 2.05 2.05 ( 2.9 1.2 1.91 2.29 ( 2.9 1.8 1.8 1.8 ( 2.9 1.59 1.59 2.22 ( 2.9 1.47 1.47 2.46 ( 2.9 1.35 1.35 2.7 ( 2.9 1.42 1.99 1.99 ( 2.9 18 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 - 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( 6.8 ) ( Outdoor unit power consumption (kW) 1.295 0.670 - 1.770 1.280 0.670 - 1.780 1.265 0.680 - 1.790 1.295 0.670 - 1.770 1.290 0.670 - 1.770 1.295 0.670 - 1.770 1.295 0.670 - 1.770 1.280 0.670 - 1.780 1.265 0.680 - 1.790 1.295 0.670 - 1.770 5.69 Power factor (%) 99 5.62 99 5.56 99 5.69 99 5.67 99 5.69 99 5.69 99 5.62 99 5.56 99 5.69 99 Current (A) ) ) ) ) ) ) ) ) ) ) MXZ-3A54VA Indoor units combination 22 25 35 42 50 22+22 22+25 22+35 22+42 22+50 25+25 25+35 25+42 25+50 35+35 35+42 35+50 42+42 42+50 50+50 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+25+25 NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Unit A Unit B Unit C 3.3 - - 3.6 - - 4.0 - - 5.4 6.8 3.3 3.18 2.62 2.34 3.3 3.62 4.18 4.46 - 2.08 4.72 - 3.4 3.4 - 2.83 2.54 2.27 3.4 3.09 2.8 3.97 4.26 4.53 3.4 3.71 4.0 - 3.4 3.4 - 3.1 3.7 - 3.4 2.27 2.17 1.89 1.74 1.59 2.08 3.4 2.27 2.17 1.89 1.74 1.59 2.36 2.27 2.46 3.02 3.32 3.62 2.36 Total 3.3 ( 1.2 3.6 ( 1.2 4.0 ( 1.2 5.4 ( 1.3 6.8 ( 1.4 6.6 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.8 6.8 ( 1.9 6.8 ( 1.9 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 - 4.2 ) ( 4.5 ) ( 4.8 ) ( 6.5 ) ( 8.2 ) ( 7.2 ) ( 8.7 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 19 Outdoor unit power consumption (kW) 0.820 0.380 - 1.090 0.910 0.380 - 1.190 1.040 0.380 - 1.300 1.400 0.370 - 1.800 1.770 0.370 - 2.300 1.500 0.410 - 1.710 1.580 0.410 - 2.350 1.580 0.410 - 2.390 1.510 0.400 - 2.300 1.440 0.390 - 2.220 1.580 0.410 - 2.390 1.580 0.410 - 2.390 1.510 0.400 - 2.300 1.440 0.390 - 2.220 1.580 0.410 - 2.390 1.510 0.410 - 2.300 1.440 0.410 - 2.220 1.440 0.410 - 2.220 1.410 0.380 - 2.130 1.390 0.360 - 2.040 1.455 0.500 - 2.120 1.455 0.500 - 2.120 1.455 0.500 - 2.120 1.380 0.490 - 2.040 1.310 0.480 - 1.960 1.455 0.500 - 2.120 3.60 Power factor (%) 99 4.00 99 4.57 99 6.15 99 7.77 99 6.59 99 6.94 99 6.94 99 6.63 99 6.32 99 6.94 99 6.94 99 6.63 99 6.32 99 6.94 99 6.63 99 6.32 99 6.32 99 6.19 99 6.10 99 6.39 99 6.39 99 6.39 99 6.06 99 5.75 99 6.39 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) MXZ-3A54VA Indoor units combination 22+25+35 22+25+42 22+25+50 22+35+35 22+35+42 25+25+25 25+25+35 25+25+42 25+25+50 25+35+35 NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Unit A 1.83 Unit B 2.07 Unit C 2.9 1.68 1.91 3.21 1.54 1.75 3.51 1.62 1.51 2.27 2.0 1.85 1.7 1.78 2.59 2.41 2.27 2.0 1.85 1.7 2.51 2.59 2.88 2.27 2.8 3.1 3.4 2.51 Total 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 6.8 ( 2.6 - 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 20 Outdoor unit power consumption (kW) 1.455 0.500 - 2.120 1.380 0.490 - 2.040 1.310 0.480 - 1.960 1.455 0.500 - 2.120 1.455 0.500 - 2.120 1.455 0.500 - 2.120 1.455 0.500 - 2.120 1.380 0.490 - 2.040 1.310 0.480 - 1.960 1.455 0.460 - 2.120 6.39 Power factor (%) 99 6.06 99 5.75 99 6.39 99 6.39 99 6.39 99 6.39 99 6.06 99 5.75 99 6.39 99 Current (A) ) ) ) ) ) ) ) ) ) ) MXZ-4A71VA Indoor units combination 22 25 35 42 50 60 22+22 22+25 22+35 22+42 22+50 22+60 25+25 25+35 25+42 25+50 25+60 35+35 35+42 35+50 35+60 42+42 42+50 42+60 50+50 50+60 NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Unit A Unit B Unit C Unit D 2.2 - - - Total ( 1.4 2.5 - - - 3.5 - - - ( 1.4 ( 1.5 4.2 - - ( 1.6 5.0 - - ( 1.6 6.0 - - ( 1.6 2.2 2.2 - ( 2.0 2.2 2.5 - ( 2.0 2.2 3.5 - ( 2.0 2.2 4.2 - - 2.08 4.72 - - ( 2.0 ( 2.0 1.82 4.98 - ( 2.0 2.5 2.5 - ( 2.0 2.5 3.5 - ( 2.0 2.5 4.2 - ( 2.0 2.27 4.53 - ( 2.0 2.0 4.8 - ( 2.0 3.4 3.4 - - 3.09 3.71 - - ( 2.0 ( 2.0 2.8 4.0 - ( 2.0 2.51 4.29 - ( 2.0 3.4 3.4 - ( 2.0 3.1 3.7 - ( 2.0 2.8 4.0 - ( 2.0 3.4 3.4 - ( 2.1 3.09 3.71 - ( 2.1 21 2.2 2.5 3.5 4.2 5.0 6.0 4.4 4.7 5.7 6.4 6.8 6.8 5.0 6.0 6.7 6.8 6.8 6.8 6.8 6.8 6.8 6.8 6.8 6.8 6.8 6.8 - 3.0 ) ( 3.3 ) ( 4.3 ) ( 5.0 ) ( 5.6 ) ( 6.6 ) ( 5.4 ) ( 5.8 ) ( 6.6 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 6.0 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( 7.1 ) ( Outdoor unit power consumption (kW) 0.590 0.420 - 0.740 0.660 0.420 - 0.830 0.950 0.430 - 1.180 1.220 0.450 - 1.420 1.500 0.480 - 1.660 2.110 0.480 - 2.290 1.180 0.540 - 1.450 1.300 0.540 - 1.630 1.800 0.540 - 2.100 2.120 0.540 - 2.540 2.440 0.550 - 2.570 2.460 0.550 - 2.600 1.420 0.540 - 1.750 2.010 0.540 - 2.540 2.220 0.540 - 2.560 2.440 0.550 - 2.590 2.460 0.550 - 2.600 2.570 0.540 - 2.600 2.500 0.540 - 2.600 2.440 0.550 - 2.600 2.460 0.550 - 2.610 2.500 0.540 - 2.600 2.440 0.550 - 2.600 2.460 0.550 - 2.610 2.380 0.560 - 2.610 2.400 0.570 - 2.620 2.59 Power factor (%) 99 2.90 99 4.17 99 5.36 99 6.59 99 9.27 99 5.18 99 5.71 99 7.91 99 9.31 99 10.72 99 10.80 99 6.24 99 8.83 99 9.75 99 10.72 99 10.80 99 11.29 99 10.98 99 10.72 99 10.80 99 10.98 99 10.72 99 10.80 99 10.45 99 10.54 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 60+60 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+35+35 22+35+42 22+35+50 22+35+60 22+42+42 22+42+50 22+42+60 22+50+50 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+35+35 Cooling capacity (kW) Unit A Unit B Unit C Unit D Total 3.4 3.4 - - 2.2 2.2 2.2 - 6.8 6.6 6.9 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 - ( 2.1 ( 2.9 2.2 2.2 2.5 ( 2.9 1.98 1.98 3.14 - 1.81 1.81 3.48 - ( 2.9 ( 2.9 1.66 1.66 3.78 ( 2.9 1.5 1.5 4.1 ( 2.9 2.16 2.47 2.47 ( 2.9 1.91 2.16 3.03 - 1.76 1.99 3.35 - ( 2.9 ( 2.9 1.61 1.83 3.66 ( 2.9 1.46 1.66 3.98 - 1.7 2.7 2.7 - ( 2.9 ( 2.9 1.58 2.51 3.01 ( 2.9 1.46 2.32 3.32 ( 2.9 1.34 2.12 3.64 ( 2.9 1.5 2.8 2.8 - 1.4 2.6 3.1 - ( 2.9 ( 2.9 1.3 2.4 3.4 ( 2.9 1.28 2.91 2.91 - 2.36 2.36 2.36 - ( 2.9 ( 2.9 2.09 2.09 2.92 ( 2.9 1.93 1.93 3.24 ( 2.9 1.78 1.78 3.54 ( 2.9 1.61 1.61 3.88 - 1.86 2.62 2.62 - ( 2.9 ( 2.9 22 7.1 ) ( 8.1 ) ( 8.3 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( Outdoor unit power consumption (kW) 2.420 0.580 - 2.630 1.750 0.670 - 2.390 1.880 0.670 - 2.510 1.990 0.670 - 2.690 1.970 0.670 - 2.700 1.960 0.680 - 2.720 1.950 0.680 - 2.740 1.990 0.670 - 2.690 1.990 0.670 - 2.690 1.970 0.670 - 2.700 1.960 0.680 - 2.720 1.950 0.680 - 2.740 1.990 0.670 - 2.690 1.970 0.670 - 2.700 1.960 0.680 - 2.720 1.950 0.680 - 2.740 1.970 0.670 - 2.700 1.960 0.680 - 2.720 1.950 0.680 - 2.740 1.940 0.690 - 2.770 1.990 0.670 - 2.690 1.99 0.670 - 2.690 1.97 0.670 - 2.700 1.96 0.680 - 2.720 1.95 0.680 - 2.740 1.99 0.670 - 2.690 10.63 Power factor (%) 99 7.69 99 8.26 99 8.74 99 8.65 99 8.61 99 8.56 99 8.74 99 8.74 99 8.65 99 8.61 99 8.56 99 8.74 99 8.65 99 8.61 99 8.56 99 8.65 99 8.61 99 8.56 99 8.52 99 8.74 99 8.74 99 8.65 99 8.61 99 8.56 99 8.74 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 25+35+42 25+35+50 25+35+60 25+42+42 25+42+50 25+50+50 35+35+35 35+35+42 35+35+50 35+42+42 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+35+35 22+22+35+42 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+35+35 Cooling capacity (kW) Unit A Unit B Unit C Unit D 1.74 2.44 2.92 - 1.61 2.26 3.23 - Total ( ( 1.48 2.07 3.55 ( 1.62 2.74 2.74 - 1.52 2.55 3.03 - ( ( 1.42 2.84 2.84 ( 2.36 2.36 2.36 ( 2.22 2.22 2.66 ( 2.07 2.07 2.96 - 1.48 2.07 3.55 - ( ( 1.77 1.77 1.77 1.77 ( 1.72 1.72 1.72 1.94 1.55 1.55 1.55 2.45 ( ( 1.44 1.44 1.44 2.78 ( 1.35 1.35 1.35 3.05 ( 1.66 1.66 1.89 1.89 ( 1.50 1.50 1.71 2.39 1.40 1.40 1.59 2.71 ( ( 1.31 1.31 1.50 2.98 ( 1.37 1.37 2.18 2.18 1.29 1.29 2.05 2.47 ( ( 1.61 1.83 1.83 1.83 ( 1.46 1.66 1.66 2.32 ( 1.36 1.55 1.55 2.64 ( 1.29 1.45 1.45 2.91 1.34 1.52 2.12 2.12 ( ( 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 2.9 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 7.1 3.7 - 23 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.5 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( Outdoor unit power consumption (kW) 1.97 0.670 - 2.700 1.96 0.680 - 2.720 1.95 0.680 - 2.740 1.97 0.670 - 2.700 1.96 0.680 - 2.720 1.94 0.690 - 2.770 1.99 0.670 - 2.690 1.97 0.670 - 2.700 1.96 0.680 - 2.720 1.97 0.670 - 2.700 1.93 0.800 - 2.750 1.93 0.800 - 2.750 1.93 0.800 - 2.750 1.92 0.800 - 2.760 1.91 0.810 - 2.780 1.93 0.800 - 2.750 1.93 0.800 - 2.750 1.92 0.800 - 2.760 1.91 0.810 - 2.780 1.93 0.800 - 2.750 1.92 0.800 - 2.760 1.93 0.800 - 2.750 1.93 0.800 - 2.750 1.92 0.800 - 2.760 1.91 0.810 - 2.780 1.93 0.800 - 2.750 8.65 Power factor (%) 99 8.61 99 8.56 99 8.65 99 8.61 99 8.52 99 8.74 99 8.65 99 8.61 99 8.65 99 8.48 99 8.48 99 8.48 99 8.43 99 8.39 99 8.48 99 8.48 99 8.43 99 8.39 99 8.48 99 8.43 99 8.48 99 8.48 99 8.43 99 8.39 99 8.48 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+25+35+42 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+35+35 Cooling capacity (kW) Unit A Unit B Unit C Unit D Total 1.26 1.43 2.00 2.41 1.77 1.77 1.77 1.77 7.1 7.1 7.1 7.1 7.1 7.1 - ( 3.7 ( 3.7 1.61 1.61 1.61 2.27 ( 3.7 1.51 1.51 1.51 2.57 1.42 1.42 1.42 2.84 ( 3.7 ( 3.7 1.48 1.48 2.07 2.07 ( 3.7 24 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( Outdoor unit power consumption (kW) 1.92 0.800 - 2.760 1.93 0.800 - 2.750 1.93 0.800 - 2.750 1.92 0.800 - 2.760 1.91 0.810 - 2.780 1.93 0.800 - 2.750 8.43 Power factor (%) 99 8.48 99 8.48 99 8.43 99 8.39 99 8.48 99 Current (A) ) ) ) ) ) ) Indoor units combination 22 25 35 42 50 60 22+22 22+25 22+35 22+42 22+50 22+60 25+25 25+35 25+42 25+50 25+60 35+35 35+42 35+50 35+60 42+42 42+50 42+60 50+50 50+60 Heating capacity (kW) Unit A Unit B Unit C Unit D Total 3.3 - - - 3.6 - - - 3.3 3.6 4.0 5.4 7.2 7.9 6.6 6.9 7.3 8.6 8.6 8.6 7.2 7.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 - 4.0 - - - - - 7.2 - - - 3.3 3.23 3.3 3.67 - - 3.26 5.34 - - 6.29 - - 3.6 3.6 - - 3.21 2.87 4.43 5.39 5.73 - - 4.3 4.3 - - 5.06 - - 3.17 5.43 - - 3.9 3.5 4.3 4.7 5.1 - 1.4 ( 1.4 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 - 3.54 4.3 ( - - - 1.3 - 6.07 4.69 ( - 2.53 3.91 1.2 - 2.31 3.17 ( - - - 1.2 - 4.48 5.97 ( - 2.82 2.63 1.2 - 5.4 7.9 ( ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 - 4.3 4.3 - - 3.91 4.69 - - ( 1.9 ( 1.9 25 4.2 ) ( 4.5 ) ( 4.8 ) ( 6.5 ) ( 8.2 ) ( 8.6 ) ( 7.2 ) ( 8.7 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( Outdoor unit power consumption (kW) 0.820 0.380 - 1.090 0.910 0.380 - 1.190 1.040 0.380 - 1.300 1.460 0.370 - 1.800 1.880 0.370 - 2.300 2.150 0.360 - 2.410 1.500 0.410 - 1.710 1.610 0.410 - 2.350 1.770 0.410 - 2.390 1.940 0.400 - 2.300 2.110 0.390 - 2.220 2.090 0.380 - 2.220 1.710 0.410 - 2.390 1.890 0.410 - 2.390 2.000 0.400 - 2.300 2.110 0.390 - 2.220 2.090 0.380 - 2.220 2.030 0.410 - 2.390 2.070 0.400 - 2.300 2.110 0.390 - 2.220 2.090 0.380 - 2.220 2.090 0.400 - 2.300 2.110 0.390 - 2.220 2.090 0.380 - 2.220 1.820 0.360 - 2.040 1.820 0.360 - 2.040 3.60 Power factor (%) 99 4.00 99 4.57 99 6.41 99 8.26 99 9.44 99 6.59 99 7.07 99 7.77 99 8.52 99 9.27 99 9.18 99 7.51 99 8.30 99 8.78 99 9.27 99 9.18 99 8.92 99 9.09 99 9.27 99 9.18 99 9.18 99 9.27 99 9.18 99 7.99 99 7.99 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 60+60 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+35+35 22+35+42 22+35+50 22+35+60 22+42+42 22+42+50 22+42+60 22+50+50 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+35+35 Heating capacity (kW) Unit A Unit B Unit C Unit D Total 4.3 4.3 - - 2.87 2.87 2.87 - 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 - 2.74 2.74 3.12 2.39 3.82 - 2.2 2.2 4.2 - 1.82 2.62 2.01 1.82 2.99 4.58 4.96 2.99 - 2.12 2.42 4.06 - 2.01 4.82 - 2.06 3.27 3.27 - 1.77 1.62 3.04 2.81 2.57 3.65 4.02 4.41 - 1.66 3.17 3.77 - 3.52 3.52 - 2.86 2.86 2.86 - 2.33 2.15 2.53 2.33 2.15 3.54 3.94 4.30 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 - 1.56 2.53 ( - 3.4 4.2 2.6 - 3.4 2.9 ( - 1.8 1.5 2.6 - 1.77 1.91 ( - 3.67 4.43 2.6 - 2.62 2.22 ( - 2.31 1.95 1.9 - 2.39 2.01 ( ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 - 1.95 1.95 4.68 - 2.26 3.17 3.17 - ( 2.6 ( 2.6 26 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( Outdoor unit power consumption (kW) 1.820 0.360 - 2.040 2.020 0.500 - 2.120 2.020 0.500 - 2.120 2.020 0.500 - 2.120 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.850 0.480 - 1.960 2.020 0.500 - 2.120 2.020 0.500 - 2.120 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.850 0.480 - 1.960 2.020 0.500 - 2.120 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.850 0.480 - 1.960 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.850 0.480 - 1.960 1.670 0.460 - 1.830 2.020 0.500 - 2.120 2.020 0.500 - 2.120 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.850 0.480 - 1.960 2.020 0.500 - 2.120 7.99 Power factor (%) 99 8.87 99 8.87 99 8.87 99 8.52 99 8.17 99 8.12 99 8.87 99 8.87 99 8.52 99 8.17 99 8.12 99 8.87 99 8.52 99 8.17 99 8.12 99 8.52 99 8.17 99 8.12 99 7.33 99 8.87 99 8.87 99 8.52 99 8.17 99 8.12 99 8.87 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 25+35+42 25+35+50 25+35+60 25+42+42 25+42+50 25+50+50 35+35+35 35+35+42 35+35+50 35+42+42 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+35+35 22+22+35+42 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+35+35 Heating capacity (kW) Unit A Unit B Unit C Unit D 2.11 2.95 3.54 - 1.95 1.79 2.74 2.51 3.91 4.30 3.3 - 1.8 3.1 3.7 - 2.86 2.68 2.51 2.52 2.15 2.86 2.68 2.51 3.04 2.15 3.44 2.86 3.24 3.58 3.04 2.15 1.87 2.98 2.01 1.82 1.70 1.59 2.01 1.82 1.70 1.59 2.29 2.07 1.94 1.81 2.49 2.99 1.65 1.56 1.62 1.89 1.76 1.84 1.89 1.76 2.57 2.6 ( 2.6 ( 2.6 ( 2.6 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 3.61 1.56 2.01 ( 3.26 1.56 2.01 2.6 2.89 2.64 1.77 ( 2.29 2.64 2.22 2.6 3.71 1.66 2.22 ( 3.35 1.66 1.94 2.6 2.15 1.87 1.63 ( - 1.87 1.63 2.6 - 2.36 1.63 ( - 2.08 1.75 2.6 - 2.08 1.75 ( - 2.08 1.75 2.6 - 3.3 3.44 ( - 2.0 1.72 Total ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 ( 3.4 2.22 2.81 3.17 3.52 2.57 27 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 - 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( Outdoor unit power consumption (kW) 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.850 0.480 - 1.960 1.940 0.490 - 2.040 1.860 0.480 - 1.960 1.670 0.460 - 1.830 2.020 0.500 - 2.120 1.940 0.500 - 2.040 1.860 0.500 - 1.960 1.940 0.490 - 2.040 1.950 0.600 - 1.960 1.950 0.600 - 1.960 1.950 0.600 - 1.960 1.860 0.600 - 1.940 1.770 0.600 - 1.930 1.950 0.600 - 1.960 1.950 0.600 - 1.960 1.860 0.600 - 1.940 1.770 0.600 - 1.930 1.950 0.600 - 1.960 1.860 0.600 - 1.940 1.950 0.600 - 1.960 1.950 0.600 - 1.960 1.860 0.600 - 1.940 1.770 0.600 - 1.930 1.950 0.600 - 1.960 8.52 Power factor (%) 99 8.17 99 8.12 99 8.52 99 8.17 99 7.33 99 8.87 99 8.52 99 8.17 99 8.52 99 8.56 99 8.56 99 8.56 99 8.17 99 7.77 99 8.56 99 8.56 99 8.17 99 7.77 99 8.56 99 8.17 99 8.56 99 8.56 99 8.17 99 7.77 99 8.56 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+25+35+42 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+35+35 Heating capacity (kW) Unit A Unit B Unit C Unit D Total 1.53 1.73 2.43 2.91 2.15 2.15 2.15 2.15 8.6 8.6 8.6 8.6 8.6 8.6 - 1.95 1.95 1.95 1.83 1.83 3.11 1.72 1.72 1.72 3.44 1.79 2.51 3.4 ( 3.4 ( 3.4 2.75 1.83 1.79 ( ( 3.4 ( 3.4 ( 3.4 2.51 28 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( Outdoor unit power consumption (kW) 1.860 0.600 - 1.940 1.950 0.600 - 1.960 1.950 0.600 - 1.960 1.860 0.600 - 1.940 1.770 0.600 - 1.930 1.950 0.600 - 1.960 8.17 Power factor (%) 99 8.56 99 8.56 99 8.17 99 7.77 99 8.56 99 Current (A) ) ) ) ) ) ) MXZ-4A80VA Indoor units combination 22 25 35 42 50 60 71 22+22 22+25 22+35 22+42 22+50 22+60 22+71 25+25 25+35 25+42 25+50 25+60 25+71 35+35 35+42 35+50 35+60 35+71 42+42 NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Unit A Unit B Unit C Unit D 2.2 - - - Total ( 2.5 - - - 3.5 - - - ( ( 4.2 - - ( 5.0 - - ( 6.0 - - ( 7.1 - - ( 2.2 2.2 - ( 2.2 2.5 - ( 2.2 3.5 - - 2.2 4.2 - - ( ( 2.2 5.0 - ( 1.75 6.00 - ( 1.66 6.19 - ( 2.5 2.5 - ( 2.5 3.5 - ( 2.5 4.2 - ( 2.5 5.0 - - 2.11 5.64 - - ( ( 2.01 5.84 - ( 3.5 3.5 - ( 3.5 4.2 - ( 3.10 4.65 - ( 2.61 5.24 - ( 2.51 5.44 - ( 3.95 3.95 - ( 2.2 - 3.0 2.5 1.4 - 3.3 3.5 1.5 - 4.3 4.2 1.6 - 5.0 5.0 1.6 - 5.6 6.0 1.6 - 6.6 7.1 1.7 - 7.4 4.4 2.0 - 5.4 4.7 2.0 - 5.8 5.7 2.0 - 6.6 6.4 2.0 - 7.2 7.2 2.0 - 7.7 7.75 2.0 - 8.0 7.9 2.0 - 8.2 5.0 2.0 - 6.2 6.0 2.0 - 7.1 6.7 2.0 - 7.8 7.5 2.0 - 8.5 7.75 2.0 - 8.6 7.85 2.0 - 8.7 7.0 2.0 - 7.1 7.7 2.0 - 8.0 7.75 2.0 - 8.8 7.85 2.0 - 8.8 7.95 2.0 - 8.8 7.9 2.0 - 8.2 1.4 29 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 0.680 0.400 - 0.920 0.760 0.400 - 1.010 1.030 0.400 - 1.290 1.230 0.410 - 1.460 1.440 0.420 - 1.630 1.930 0.400 - 2.130 2.580 0.410 - 2.710 1.130 0.600 - 1.600 1.270 0.600 - 1.770 1.710 0.600 - 2.200 2.080 0.580 - 2.450 2.450 0.560 - 2.710 2.750 0.560 - 3.050 2.810 0.560 - 3.200 1.360 0.580 - 1.950 2.010 0.580 - 2.540 2.290 0.570 - 2.870 2.580 0.560 - 3.200 2.750 0.560 - 3.280 2.810 0.560 - 3.320 2.400 0.580 - 2.550 2.580 0.570 - 2.880 2.760 0.560 - 3.220 2.730 0.560 - 3.180 2.780 0.560 - 3.180 2.860 0.570 - 2.890 2.99 Power factor (%) 99 3.34 99 4.52 99 5.40 99 6.32 99 8.48 99 11.33 99 4.96 99 5.58 99 7.51 99 9.13 99 10.76 99 12.08 99 12.34 99 5.97 99 8.83 99 10.06 99 11.33 99 12.08 99 12.34 99 10.54 99 11.33 99 12.12 99 11.99 99 12.21 99 12.56 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 42+50 42+60 42+71 50+50 50+60 50+71 60+60 60+71 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+25+71 22+35+35 22+35+42 22+35+50 22+35+60 22+35+71 Cooling capacity (kW) Unit A Unit B Unit C Unit D Total 3.6 4.3 - - 3.3 4.7 - - 7.9 2.0 - 8.8 8.0 2.0 - 8.8 8.0 2.0 - 8.8 7.9 2.1 - 8.8 8.0 2.1 - 8.8 8.0 2.1 - 8.8 8.0 2.1 - 8.8 8.0 2.1 - 8.8 6.6 2.9 - 8.1 6.9 2.9 - 8.3 7.7 2.9 - 8.3 7.85 2.9 - 8.7 7.85 2.9 - 9.0 7.95 2.9 - 9.0 8.0 2.9 - 9.0 7.2 2.9 - 8.9 7.75 2.9 - 8.9 7.9 2.9 - 9.0 7.9 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 7.85 2.9 - 9.0 7.9 2.9 - 9.0 7.9 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 ( ( 3.0 5.0 - ( 3.95 3.95 - - 3.43 4.57 - - ( ( 3.27 4.73 - ( 4.00 4.00 - ( 3.84 4.16 - ( 2.2 2.2 2.2 - 2.2 2.2 2.5 - ( ( 2.14 2.14 3.42 ( 2.01 2.01 3.83 - 1.72 1.72 4.41 - ( ( 1.46 1.46 5.03 ( 1.4 1.4 5.2 ( 2.2 2.5 2.5 ( 2.08 2.36 3.31 - 1.95 2.22 3.73 - ( ( 1.79 2.04 4.07 ( 1.64 1.87 4.49 - 1.49 1.69 4.82 - ( ( 1.87 2.99 2.99 ( 1.76 2.79 3.35 ( 1.63 2.58 3.69 ( 1.5 2.4 4.1 - 1.38 2.18 4.44 - ( ( 30 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.860 0.560 - 3.190 2.880 0.560 - 3.150 2.880 0.560 - 3.150 2.780 0.590 - 3.160 2.800 0.570 - 3.120 2.800 0.570 - 3.120 2.690 0.550 - 3.080 2.690 0.550 - 3.080 1.860 0.690 - 2.410 1.970 0.670 - 2.510 2.310 0.690 - 2.970 2.310 0.690 - 2.940 2.320 0.700 - 2.920 2.370 0.680 - 2.880 2.390 0.680 - 2.880 2.100 0.690 - 2.940 2.350 0.690 - 2.970 2.360 0.690 - 2.940 2.370 0.700 - 2.920 2.390 0.680 - 2.880 2.390 0.680 - 2.880 2.350 0.690 - 2.920 2.330 0.690 - 2.900 2.320 0.700 - 2.890 2.350 0.680 - 2.860 2.350 0.680 - 2.860 12.56 Power factor (%) 99 12.65 99 12.65 99 12.21 99 12.30 99 12.30 99 11.81 99 11.81 99 8.17 99 8.65 99 10.14 99 10.14 99 10.19 99 10.41 99 10.50 99 9.22 99 10.32 99 10.36 99 10.41 99 10.50 99 10.50 99 10.32 99 10.23 99 10.19 99 10.32 99 10.32 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+42+42 22+42+50 22+42+60 22+42+71 22+50+50 22+50+60 22+50+71 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+25+71 25+35+35 25+35+42 25+35+50 25+35+60 25+35+71 25+42+42 25+42+50 25+42+60 25+42+71 25+50+50 25+50+60 35+35+35 35+35+42 Cooling capacity (kW) Unit A Unit B Unit C Unit D Total 1.65 3.15 3.15 - 1.53 2.93 3.49 - 7.95 2.9 - 9.0 7.95 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 7.5 2.9 - 9.0 7.75 2.9 - 9.0 7.9 2.9 - 9.0 7.9 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 7.85 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 8.0 2.9 - 9.0 7.95 2.9 - 9.0 8.0 2.9 - 9.0 ( ( 1.4 2.7 3.9 ( 1.3 2.5 4.2 - 1.44 3.28 3.28 - ( ( 1.33 3.03 3.64 ( 1.23 2.80 3.97 ( 2.5 2.5 2.5 ( 2.28 2.28 3.19 - 2.14 2.14 3.62 - ( ( 1.98 1.98 3.94 ( 1.82 1.82 4.36 - 1.65 1.65 4.70 - ( ( 2.07 2.89 2.89 ( 1.96 2.75 3.29 ( 1.82 2.54 3.64 ( 1.67 2.33 4.00 - 1.53 2.14 4.33 - ( ( 1.8 3.1 3.1 ( 1.7 2.9 3.4 - 1.6 2.6 3.8 - ( ( 1.45 2.43 4.12 ( 1.6 3.2 3.2 ( 1.48 2.96 3.56 ( 2.65 2.65 2.65 - 2.5 2.5 3.0 - ( ( 31 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.300 0.680 - 2.880 2.290 0.690 - 2.870 2.320 0.670 - 2.840 2.320 0.670 - 2.840 2.330 0.680 - 2.860 2.300 0.660 - 2.830 2.300 0.660 - 2.830 2.250 0.690 - 3.010 2.350 0.690 - 2.970 2.360 0.690 - 2.940 2.370 0.700 - 2.920 2.390 0.680 - 2.880 2.390 0.680 - 2.880 2.350 0.690 - 2.920 2.360 0.690 - 2.900 2.380 0.700 - 2.890 2.350 0.680 - 2.860 2.350 0.680 - 2.860 2.330 0.670 - 2.870 2.350 0.680 - 2.860 2.320 0.670 - 2.840 2.320 0.670 - 2.840 2.330 0.660 - 2.840 2.300 0.660 - 2.830 2.280 0.720 - 2.910 2.270 0.710 - 2.890 10.10 Power factor (%) 99 10.06 99 10.19 99 10.19 99 10.23 99 10.10 99 10.10 99 9.88 99 10.32 99 10.36 99 10.41 99 10.50 99 10.50 99 10.32 99 10.36 99 10.45 99 10.32 99 10.32 99 10.23 99 10.32 99 10.19 99 10.19 99 10.23 99 10.10 99 10.01 99 9.97 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 35+35+50 35+35+60 35+35+71 35+42+42 35+42+50 35+42+60 35+50+50 35+50+60 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+42 22+22+35+50 22+22+35+60 22+22+42+42 Cooling capacity (kW) Unit A Unit B Unit C Unit D 2.33 2.33 3.34 - 2.15 2.15 3.70 - 1.99 1.99 4.02 - 2.4 2.8 2.8 - 2.20 2.65 3.15 - 2.0 2.08 1.93 2.5 2.96 2.76 3.5 2.96 3.31 - 1.95 1.95 1.95 1.95 1.90 1.90 1.90 2.15 1.73 1.73 1.73 2.76 1.63 1.63 1.63 3.11 1.52 1.52 1.52 3.44 1.4 1.28 1.87 1.4 1.28 1.87 1.4 1.28 2.13 3.8 4.16 2.13 1.68 1.68 1.91 1.91 1.58 1.58 1.80 3.04 1.48 1.48 1.68 3.36 1.36 1.36 1.55 3.73 1.26 1.26 1.43 4.05 1.54 1.45 1.36 1.54 1.45 1.36 2.46 2.31 2.18 2.46 2.79 3.10 1.12 1.12 1.92 3.84 1.4 1.4 2.6 2.6 Total 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 8.0 ( 2.9 - 9.0 7.8 ( 3.7 - 9.2 7.85 ( 3.7 - 9.2 7.95 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 7.18 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 8.0 ( 3.7 - 9.2 32 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.260 0.700 - 2.870 2.260 0.680 - 2.840 2.260 0.680 - 2.840 2.260 0.700 - 2.870 2.250 0.690 - 2.850 2.240 0.670 - 2.820 2.240 0.680 - 2.840 2.220 0.660 - 2.810 2.180 0.810 - 2.670 2.190 0.810 - 2.670 2.210 0.810 - 2.650 2.180 0.800 - 2.630 2.150 0.790 - 2.620 2.130 0.770 - 2.590 2.130 0.770 - 2.590 2.190 0.810 - 2.670 2.210 0.810 - 2.650 2.180 0.800 - 2.630 2.150 0.790 - 2.620 2.130 0.770 - 2.590 2.130 0.770 - 2.590 2.210 0.810 - 2.620 2.160 0.800 - 2.600 2.120 0.790 - 2.590 2.100 0.770 - 2.560 2.130 0.790 - 2.580 9.93 Power factor (%) 99 9.93 99 9.93 99 9.93 99 9.88 99 9.84 99 9.84 99 9.75 99 9.57 99 9.62 99 9.71 99 9.57 99 9.44 99 9.35 99 9.35 99 9.62 99 9.71 99 9.57 99 9.44 99 9.35 99 9.35 99 9.71 99 9.49 99 9.31 99 9.22 99 9.35 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+42+50 22+22+50+50 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+25+60 22+25+35+35 22+25+35+42 22+25+35+50 22+25+35+60 22+35+35+35 22+35+35+42 22+35+35+50 22+35+42+42 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+25+60 25+25+35+35 25+25+35+42 25+25+35+50 25+35+35+35 25+35+35+42 35+35+35+35 Cooling capacity (kW) Unit A Unit B Unit C Unit D Total 1.3 1.3 2.5 2.9 1.22 1.22 2.78 2.78 8.0 3.7 - 9.2 8.0 3.7 - 9.2 7.9 3.7 - 9.2 7.95 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 7.92 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 8.0 3.7 - 9.2 ( ( 1.78 2.04 2.04 2.04 ( 1.63 1.86 1.86 2.60 1.54 1.75 1.75 2.96 ( ( 1.44 1.64 1.64 3.28 ( 1.33 1.52 1.52 3.64 ( 1.51 1.71 2.39 2.39 ( 1.42 1.61 2.26 2.71 1.33 1.52 2.12 3.03 ( ( 1.24 1.41 1.97 3.38 ( 1.4 2.2 2.2 2.2 1.31 2.09 2.09 2.51 ( ( 1.24 1.97 1.97 2.82 ( 1.2 2.0 2.4 2.4 ( 1.98 1.98 1.98 1.98 ( 1.82 1.82 1.82 2.54 1.71 1.71 1.71 2.87 ( ( 1.6 1.6 1.6 3.2 ( 1.48 1.48 1.48 3.56 1.67 1.67 2.33 2.33 ( ( 1.57 1.57 2.20 2.66 ( 1.48 1.48 2.08 2.96 ( 1.55 2.15 2.15 2.15 ( 1.46 2.04 2.04 2.46 2.0 2.0 2.0 2.0 ( ( 33 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.090 0.780 - 2.570 2.070 0.770 - 2.560 2.140 0.810 - 2.670 2.210 0.810 - 2.650 2.180 0.800 - 2.630 2.150 0.790 - 2.620 2.130 0.770 - 2.590 2.210 0.810 - 2.620 2.160 0.800 - 2.600 2.120 0.790 - 2.590 2.100 0.770 - 2.560 2.200 0.810 - 2.610 2.140 0.800 - 2.600 2.080 0.790 - 2.590 2.080 0.790 - 2.590 2.150 0.810 - 2.670 2.220 0.810 - 2.650 2.180 0.800 - 2.630 2.150 0.790 - 2.620 2.130 0.770 - 2.590 2.210 0.810 - 2.620 2.160 0.800 - 2.600 2.120 0.790 - 2.590 2.200 0.810 - 2.610 2.150 0.800 - 2.590 2.190 0.810 - 2.580 9.18 Power factor (%) 99 9.09 99 9.40 99 9.71 99 9.57 99 9.44 99 9.35 99 9.71 99 9.49 99 9.31 99 9.22 99 9.66 99 9.40 99 9.13 99 9.13 99 9.44 99 9.75 99 9.57 99 9.44 99 9.35 99 9.71 99 9.49 99 9.31 99 9.66 99 9.44 99 9.62 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22 25 35 42 50 60 71 22+22 22+25 22+35 22+42 22+50 22+60 22+71 25+25 25+35 25+42 25+50 25+60 25+71 35+35 35+42 35+50 35+60 35+71 42+42 Heating capacity (kW) Unit A Unit B Unit C Unit D 3.3 - - - 3.6 - - - Total ( 1.3 ( 1.2 4.0 - - ( 1.2 5.4 - - - 7.2 - - - ( 1.3 ( 1.4 7.9 - - ( 1.4 8.6 - - ( 1.6 3.3 3.3 - ( 1.8 3.23 3.67 - - 2.82 4.48 - - ( 1.8 ( 1.8 2.78 5.32 - ( 1.8 2.72 6.18 - - 2.52 6.88 - - ( 1.8 ( 1.8 2.22 7.18 - ( 1.8 3.6 3.6 - ( 1.8 3.17 4.43 - ( 1.8 3.1 5.2 - - 3.0 6.0 - - ( 1.8 ( 1.8 2.76 6.64 - ( 1.8 2.45 6.95 - - 4.0 4.0 - - ( 1.8 ( 1.8 3.95 4.75 - ( 1.8 3.87 5.53 - ( 1.8 3.46 5.94 - ( 1.8 3.1 6.3 - - 4.7 4.7 - - ( 1.8 ( 1.8 34 3.3 - 4.2 3.6 - 4.5 4.0 - 4.8 5.4 - 6.5 7.2 - 8.2 7.9 - 8.6 8.6 - 9.2 6.6 - 7.2 6.9 - 8.7 7.3 - 9.2 8.1 - 9.6 8.9 - 9.9 9.4 - 9.9 9.4 - 9.9 7.2 - 9.1 7.6 - 9.5 8.3 - 9.8 9.0 - 10.1 9.4 - 10.1 9.4 - 10.1 8.0 - 9.8 8.7 - 10.2 9.4 - 10.5 9.4 - 10.5 9.4 - 10.5 9.4 - 10.9 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 1.050 0.340 - 1.380 1.110 0.340 - 1.510 1.210 0.330 - 1.570 1.990 0.330 - 2.140 2.770 0.330 - 2.710 2.700 0.330 - 3.060 3.220 0.360 - 3.520 2.020 0.480 - 2.760 2.120 0.480 - 3.000 2.130 0.480 - 3.110 2.300 0.470 - 3.120 2.470 0.460 - 3.140 2.710 0.460 - 3.140 2.710 0.460 - 3.140 2.170 0.480 - 3.140 2.210 0.480 - 3.230 2.360 0.470 - 3.240 2.520 0.460 - 3.260 2.710 0.460 - 3.260 2.710 0.460 - 3.260 2.370 0.480 - 3.230 2.460 0.470 - 3.320 2.560 0.460 - 3.420 2.560 0.460 - 3.420 2.560 0.460 - 3.420 2.460 0.470 - 3.370 4.61 Power factor (%) 99 4.87 99 5.31 99 8.74 99 12.17 99 11.86 99 14.14 99 8.87 99 9.31 99 9.35 99 10.10 99 10.85 99 11.90 99 11.90 99 9.53 99 9.71 99 10.36 99 11.07 99 11.90 99 11.90 99 10.41 99 10.80 99 11.24 99 11.24 99 11.24 99 10.80 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 42+50 42+60 42+71 50+50 50+60 50+71 60+60 60+71 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+25+71 22+35+35 22+35+42 22+35+50 22+35+60 22+35+71 Heating capacity (kW) Unit A Unit B Unit C Unit D 4.3 5.1 - - 3.9 5.5 - - Total ( 1.8 ( 1.8 3.5 5.9 - ( 1.8 4.7 4.7 - - 4.3 5.1 - - ( 1.9 ( 1.9 3.88 5.52 - ( 1.9 4.7 4.7 - ( 1.9 4.31 5.09 - ( 1.9 2.9 2.9 2.9 - 2.81 2.81 3.18 - ( 2.6 ( 2.6 2.62 2.62 4.16 ( 2.6 2.4 2.4 4.6 - 2.2 2.2 5.0 - ( 2.6 ( 2.6 1.99 1.99 5.42 ( 2.6 1.8 1.8 5.8 ( 2.6 2.72 3.09 3.09 ( 2.6 2.52 2.87 4.01 - 2.32 2.64 4.44 - ( 2.6 ( 2.6 2.13 2.42 4.85 ( 2.6 1.93 2.20 5.27 - 1.75 1.99 5.66 - ( 2.6 ( 2.6 2.24 3.58 3.58 ( 2.6 2.09 3.32 3.99 ( 2.7 1.93 3.07 4.39 ( 2.7 1.77 2.81 4.82 - 1.62 2.57 5.21 - ( 2.7 ( 2.7 35 9.4 - 10.9 9.4 - 10.9 9.4 - 10.9 9.4 - 11.2 9.4 - 11.2 9.4 - 11.2 9.4 - 11.2 9.4 - 11.2 8.7 - 10.6 8.8 - 11.1 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 8.9 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.460 0.460 - 3.370 2.460 0.460 - 3.370 2.460 0.460 - 3.370 2.370 0.440 - 3.320 2.370 0.440 - 3.320 2.370 0.440 - 3.320 2.370 0.440 - 3.320 2.370 0.440 - 3.320 2.150 0.530 - 3.060 2.170 0.530 - 3.300 2.310 0.530 - 3.400 2.210 0.520 - 3.360 2.120 0.510 - 3.330 2.120 0.510 - 3.330 2.120 0.510 - 3.330 2.170 0.530 - 3.420 2.270 0.530 - 3.410 2.180 0.520 - 3.370 2.100 0.510 - 3.330 2.100 0.510 - 3.330 2.100 0.510 - 3.330 2.210 0.530 - 3.400 2.130 0.520 - 3.310 2.050 0.510 - 3.230 2.050 0.510 - 3.230 2.050 0.510 - 3.230 10.80 Power factor (%) 99 10.80 99 10.80 99 10.41 99 10.41 99 10.41 99 10.41 99 10.41 99 9.44 99 9.53 99 10.14 99 9.71 99 9.31 99 9.31 99 9.31 99 9.53 99 9.97 99 9.57 99 9.22 99 9.22 99 9.22 99 9.71 99 9.35 99 9.00 99 9.00 99 9.00 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+42+42 22+42+50 22+42+60 22+42+71 22+50+50 22+50+60 22+50+71 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+25+71 25+35+35 25+35+42 25+35+50 25+35+60 25+35+71 25+42+42 25+42+50 25+42+60 25+42+71 25+50+50 25+50+60 35+35+35 35+35+42 Heating capacity (kW) Unit A Unit B Unit C Unit D 2.0 3.7 3.7 - 1.8 3.5 4.1 - Total ( 2.7 ( 2.7 1.7 3.2 4.5 ( 2.7 1.53 2.92 4.95 - 1.70 3.85 3.85 - ( 2.7 ( 2.7 1.57 3.56 4.27 ( 2.7 1.45 3.29 4.66 ( 2.7 3.0 3.0 3.0 ( 2.6 2.76 2.76 3.87 - 2.55 2.55 4.30 - ( 2.6 ( 2.6 2.35 2.35 4.70 ( 2.6 2.14 2.14 5.12 - 1.94 1.94 5.52 - ( 2.6 ( 2.6 2.48 3.46 3.46 ( 2.6 2.30 3.23 3.87 ( 2.7 2.14 2.99 4.27 ( 2.7 1.96 2.74 4.70 - 1.8 2.5 5.1 - ( 2.7 ( 2.7 2.2 3.6 3.6 ( 2.7 2.0 3.4 4.0 - 1.9 3.1 4.4 - ( 2.7 ( 2.7 1.7 2.9 4.8 ( 2.7 1.88 3.76 3.76 ( 2.7 1.74 3.48 4.18 ( 2.7 3.13 3.13 3.13 - 2.93 2.93 3.54 - ( 2.6 ( 2.7 36 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.0 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.080 0.510 - 3.240 2.000 0.500 - 3.160 2.000 0.500 - 3.160 2.000 0.500 - 3.160 1.960 0.490 - 3.100 1.960 0.490 - 3.100 1.960 0.490 - 3.100 2.170 0.530 - 3.420 2.250 0.530 - 3.410 2.170 0.520 - 3.360 2.090 0.510 - 3.320 2.090 0.510 - 3.320 2.090 0.510 - 3.320 2.190 0.530 - 3.400 2.110 0.520 - 3.310 2.030 0.510 - 3.230 2.030 0.510 - 3.230 2.030 0.510 - 3.230 2.060 0.510 - 3.240 1.980 0.500 - 3.160 1.980 0.500 - 3.160 1.980 0.500 - 3.160 1.940 0.490 - 3.100 1.940 0.490 - 3.100 2.170 0.530 - 3.380 2.090 0.520 - 3.270 9.13 Power factor (%) 99 8.78 99 8.78 99 8.78 99 8.61 99 8.61 99 8.61 99 9.53 99 9.88 99 9.53 99 9.18 99 9.18 99 9.18 99 9.62 99 9.27 99 8.92 99 8.92 99 8.92 99 9.05 99 8.70 99 8.70 99 8.70 99 8.52 99 8.52 99 9.53 99 9.18 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 35+35+50 35+35+60 35+35+71 35+42+42 35+42+50 35+42+60 35+50+50 35+50+60 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+42 22+22+35+50 22+22+35+60 22+22+42+42 Heating capacity (kW) Unit A Unit B Unit C Unit D 2.74 2.74 3.92 - 2.53 2.53 4.34 - Total ( 2.7 ( 2.7 2.33 2.33 4.74 ( 2.7 2.8 3.3 3.3 - 2.6 3.1 3.7 - ( 2.7 ( 2.7 2.4 2.9 4.1 ( 2.7 2.44 3.48 3.48 ( 2.7 2.27 3.24 3.89 ( 2.7 2.35 2.35 2.35 2.35 2.27 2.27 2.27 2.59 ( 3.4 ( 3.4 2.05 2.05 2.05 3.25 ( 3.4 1.91 1.91 1.91 3.67 1.78 1.78 1.78 4.06 ( 3.5 ( 3.5 1.64 1.64 1.64 4.48 ( 3.5 1.51 1.51 1.51 4.87 ( 3.5 2.2 2.2 2.5 2.5 ( 3.5 1.99 1.99 2.26 3.16 1.86 1.86 2.12 3.56 ( 3.4 ( 3.5 1.74 1.74 1.97 3.95 ( 3.5 1.60 1.60 1.83 4.37 1.48 1.48 1.68 4.76 ( 3.5 ( 3.5 1.81 1.81 2.89 2.89 ( 3.4 1.71 1.71 2.72 3.26 ( 3.5 1.60 1.60 2.55 3.65 ( 3.5 1.49 1.49 2.37 4.05 1.6 1.6 3.1 3.1 ( 3.5 ( 3.4 37 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.010 0.510 - 3.160 2.010 0.510 - 3.160 2.010 0.510 - 3.160 2.040 0.510 - 3.200 1.960 0.500 - 3.090 1.960 0.500 - 3.090 1.920 0.490 - 3.030 1.920 0.490 - 3.030 2.020 0.590 - 3.420 1.990 0.590 - 3.410 1.960 0.590 - 3.390 1.930 0.580 - 3.320 1.910 0.580 - 3.260 1.910 0.580 - 3.260 1.910 0.580 - 3.260 1.980 0.590 - 3.400 1.940 0.590 - 3.390 1.910 0.580 - 3.330 1.890 0.580 - 3.270 1.890 0.580 - 3.270 1.890 0.580 - 3.270 1.910 0.590 - 3.340 1.860 0.580 - 3.280 1.820 0.580 - 3.220 1.820 0.580 - 3.220 1.820 0.560 - 3.230 8.83 Power factor (%) 99 8.83 99 8.83 99 8.96 99 8.61 99 8.61 99 8.43 99 8.43 99 8.87 99 8.74 99 8.61 99 8.48 99 8.39 99 8.39 99 8.39 99 8.70 99 8.52 99 8.39 99 8.30 99 8.30 99 8.30 99 8.39 99 8.17 99 7.99 99 7.99 99 7.99 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+42+50 22+22+50+50 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+25+60 22+25+35+35 22+25+35+42 22+25+35+50 22+25+35+50 22+35+35+35 22+35+35+42 22+35+35+50 22+35+42+42 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+25+60 25+25+35+35 25+25+35+42 25+25+35+50 25+35+35+35 25+35+35+42 35+35+35+35 Heating capacity (kW) Unit A Unit B Unit C Unit D 1.5 1.5 2.9 3.5 1.44 1.44 3.26 3.26 Total ( 3.4 ( 3.4 2.14 2.42 2.42 2.42 ( 3.4 1.93 2.20 2.20 3.07 1.81 2.06 2.06 3.47 ( 3.4 ( 3.5 1.70 1.93 1.93 3.84 ( 3.5 1.57 1.78 1.78 4.27 ( 3.5 1.77 2.01 2.81 2.81 ( 3.4 1.67 1.90 2.65 3.18 1.57 1.78 2.49 3.56 ( 3.5 ( 3.5 1.46 1.65 2.32 3.97 ( 3.5 1.63 2.59 2.59 2.59 1.53 2.46 2.46 2.95 ( 3.4 ( 3.5 1.45 2.32 2.32 3.31 ( 3.5 1.5 2.3 2.8 2.8 ( 3.4 2.35 2.35 2.35 2.35 ( 3.4 2.14 2.14 2.14 2.98 2.01 2.01 2.01 3.37 ( 3.4 ( 3.5 1.88 1.88 1.88 3.76 ( 3.5 1.74 1.74 1.74 4.18 1.96 1.96 2.74 2.74 ( 3.5 ( 3.4 1.85 1.85 2.59 3.11 ( 3.5 1.74 1.74 2.44 3.48 ( 3.5 1.81 2.53 2.53 2.53 ( 3.4 1.72 2.40 2.40 2.88 2.35 2.35 2.35 2.35 ( 3.5 ( 3.4 38 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 9.4 - 11.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 1.780 0.560 - 3.170 1.750 0.550 - 3.130 1.960 0.590 - 3.390 1.920 0.590 - 3.370 1.890 0.580 - 3.300 1.870 0.580 - 3.230 1.870 0.580 - 3.230 1.890 0.590 - 3.320 1.840 0.580 - 3.260 1.800 0.580 - 3.200 1.800 0.580 - 3.200 1.860 0.590 - 3.280 1.820 0.580 - 3.240 1.780 0.580 - 3.210 1.780 0.560 - 3.200 1.950 0.590 - 3.390 1.910 0.590 - 3.350 1.880 0.580 - 3.280 1.860 0.580 - 3.210 1.860 0.580 - 3.210 1.870 0.590 - 3.300 1.820 0.580 - 3.240 1.780 0.580 - 3.190 1.840 0.590 - 3.260 1.790 0.580 - 3.200 1.930 0.590 - 3.230 7.82 Power factor (%) 99 7.69 99 8.61 99 8.43 99 8.30 99 8.21 99 8.21 99 8.30 99 8.08 99 7.91 99 7.91 99 8.17 99 7.99 99 7.82 99 7.82 99 8.56 99 8.39 99 8.26 99 8.17 99 8.17 99 8.21 99 7.99 99 7.82 99 8.08 99 7.86 99 8.48 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) MXZ-5A100VA Indoor units combination 22 25 35 42 50 60 71 22+22 22+25 22+35 22+42 22+50 22+60 22+71 25+25 25+35 25+42 25+50 25+60 25+71 35+35 35+42 35+50 35+60 35+71 42+42 NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E 2.20 - - - - Total ( 2.50 - - - - 3.50 - - - - 4.20 5.00 6.00 7.10 2.20 2.20 2.20 2.50 - - 4.20 - - - 1.87 2.50 2.50 2.50 6.03 2.50 3.50 4.20 - - 5.51 - - - 3.36 3.21 2.91 2.74 3.90 4.04 4.59 4.99 5.56 3.90 - - 1.7 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 - 2.29 3.50 ( - - 3.50 0.6 - - - ( - - - 1.6 - 5.00 5.84 ( - 2.50 2.06 1.6 - 2.20 5.71 ( - - 2.09 1.5 - - - ( - - - 1.4 - 3.50 5.00 ( - 2.20 2.20 1.4 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 ( 2.0 39 2.2 2.5 3.5 4.2 5.0 6.0 7.1 4.4 4.7 5.7 6.4 7.2 7.8 7.9 5.0 6.0 6.7 7.5 7.8 7.9 7.0 7.4 7.8 7.9 8.3 7.8 - 3.0 ) ( 3.3 ) ( 4.3 ) ( 5.0 ) ( 5.6 ) ( 6.6 ) ( 7.4 ) ( 5.4 ) ( 5.8 ) ( 6.6 ) ( 7.2 ) ( 7.7 ) ( 8.0 ) ( 8.2 ) ( 6.2 ) ( 7.1 ) ( 7.8 ) ( 8.5 ) ( 8.6 ) ( 8.7 ) ( 7.1 ) ( 8.0 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( 8.8 ) ( Outdoor unit power consumption (kW) 0.680 0.400 - 0.920 0.760 0.400 - 1.010 1.030 0.400 - 1.290 1.230 0.410 - 1.460 1.440 0.420 - 1.630 1.930 0.400 - 2.130 2.580 0.410 - 2.710 1.130 0.600 - 1.600 1.270 0.600 - 1.770 1.710 0.600 - 2.200 2.080 0.580 - 2.450 2.450 0.560 - 2.710 2.750 0.560 - 3.050 2.810 0.560 - 3.200 1.360 0.580 - 1.950 2.010 0.540 - 2.540 2.290 0.550 - 2.870 2.580 0.560 - 3.200 2.750 0.560 - 3.280 2.810 0.560 - 3.320 2.400 0.540 - 2.550 2.580 0.550 - 2.910 2.760 0.560 - 3.280 2.730 0.560 - 3.280 3.050 0.560 - 3.280 2.760 0.560 - 3.280 2.99 Power factor (%) 99 3.34 99 4.52 99 5.40 99 6.32 99 8.48 99 11.33 99 4.96 99 5.58 99 7.51 99 9.13 99 10.76 99 12.08 99 12.34 99 5.97 99 8.83 99 10.06 99 11.33 99 12.08 99 12.34 99 10.54 99 11.33 99 12.12 99 11.99 99 13.39 99 12.12 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 42+50 42+60 42+71 50+50 50+60 50+71 60+60 60+71 71+71 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+25+71 22+35+35 22+35+42 22+35+50 22+35+60 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 3.61 4.29 - - - 3.34 4.76 - - - 7.9 8.1 8.6 8.3 8.6 8.9 8.9 9.1 9.1 6.6 6.9 7.7 7.8 7.9 8.6 8.6 7.2 7.8 8.2 8.5 8.6 8.7 7.9 8.2 8.5 8.7 - 3.20 5.40 - - 4.15 - - - 3.91 4.69 - - - 4.45 4.17 5.22 4.45 4.93 - - - 2.20 2.20 2.20 - - - 2.14 3.42 - - 1.99 1.99 3.82 - - 1.82 1.65 1.85 1.82 1.65 4.20 4.96 5.30 - - 2.09 2.38 3.33 - - - 2.19 4.38 - - 1.77 2.01 4.82 - - 1.88 1.82 1.84 3.01 2.90 5.24 3.01 3.48 - 2.1 ( 2.1 ( 2.1 ( 2.1 ( 2.1 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 - 1.93 1.62 ( - 2.50 3.87 2.1 - 2.50 2.30 ( - 2.20 2.03 2.1 - 2.14 1.85 ( - - 2.50 2.0 - 4.55 2.20 ( - 4.55 2.20 2.0 - 4.15 3.68 ( ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 - 1.75 2.78 3.97 - - 1.64 2.60 4.46 - - ( 2.9 ( 2.9 40 8.8 ) ( 8.8 ) ( 9.1 ) ( 9.1 ) ( 9.2 ) ( 9.3 ) ( 9.3 ) ( 9.4 ) ( 9.5 ) ( 8.1 ) ( 8.3 ) ( 9.0 ) ( 9.0 ) ( 9.0 ) ( 9.4 ) ( 9.4 ) ( 8.9 ) ( 9.0 ) ( 9.2 ) ( 9.4 ) ( 9.4 ) ( 9.4 ) ( 9.0 ) ( 9.2 ) ( 9.4 ) ( 9.4 ) ( Outdoor unit power consumption (kW) 2.740 0.560 - 3.280 2.890 0.560 - 3.280 3.170 0.550 - 3.440 3.050 0.590 - 3.480 3.250 0.570 - 3.600 3.300 0.550 - 3.600 3.300 0.550 - 3.600 3.450 0.550 - 3.700 3.400 0.550 - 3.700 1.860 0.690 - 2.410 1.970 0.670 - 2.510 2.310 0.690 - 2.970 2.310 0.690 - 2.940 2.320 0.700 - 2.920 2.650 0.680 - 3.000 2.680 0.680 - 3.000 2.100 0.690 - 2.940 2.350 0.690 - 2.970 2.500 0.690 - 3.000 2.650 0.700 - 3.040 2.680 0.680 - 3.000 2.680 0.680 - 3.000 2.350 0.690 - 2.920 2.470 0.690 - 2.960 2.600 0.700 - 3.010 2.630 0.680 - 2.970 12.03 Power factor (%) 99 12.69 99 13.92 99 13.39 99 14.27 99 14.49 99 14.49 99 15.15 99 14.93 99 8.17 99 8.65 99 10.14 99 10.14 99 10.19 99 11.64 99 11.77 99 9.22 99 10.32 99 10.98 99 11.64 99 11.77 99 11.77 99 10.32 99 10.85 99 11.42 99 11.55 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+35+71 22+42+42 22+42+50 22+42+60 22+42+71 22+50+50 22+50+60 22+50+71 22+60+60 22+60+71 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+25+71 25+35+35 25+35+42 25+35+50 25+35+60 25+35+71 25+42+42 25+42+50 25+42+60 25+42+71 25+50+50 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 1.58 2.52 5.10 - - 1.70 3.25 3.25 - - 9.2 8.2 8.6 9.0 9.2 9.0 9.2 9.2 9.2 9.3 7.5 7.8 8.2 8.5 8.6 9.0 7.9 8.3 8.6 9.0 9.2 8.6 8.8 9.1 9.2 9.2 - 1.66 3.17 3.77 - 3.05 4.35 - - 1.50 2.86 4.84 - - 1.53 1.41 3.69 3.48 3.22 3.69 4.19 4.57 - - 1.33 3.65 4.32 - - - 2.29 3.22 - - 2.23 2.23 3.74 - - 1.95 1.86 2.13 1.95 1.86 4.24 4.70 5.28 - - 2.03 2.85 3.42 - - - 2.63 4.50 - - 1.75 2.46 4.99 - - 1.88 1.79 3.31 3.16 3.01 3.31 3.76 4.30 - 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 - 1.87 1.98 ( - 2.91 3.91 2.9 - 2.91 2.74 ( - 2.08 1.95 2.9 - 2.29 2.13 ( - 3.89 2.50 2.9 - 3.89 2.50 ( - 1.42 2.50 2.9 - 1.60 1.62 ( ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 - 1.67 2.80 4.73 - - 1.84 3.68 3.68 - - ( 2.9 ( 2.9 41 9.8 ) ( 9.4 ) ( 9.4 ) ( 9.6 ) ( 9.9 ) ( 9.8 ) ( 9.9 ) ( 10.0 ) ( 10.0 ) ( 10.5 ) ( 9.0 ) ( 9.0 ) ( 9.2 ) ( 9.4 ) ( 9.4 ) ( 9.8 ) ( 9.0 ) ( 9.2 ) ( 9.4 ) ( 9.8 ) ( 9.9 ) ( 9.4 ) ( 9.6 ) ( 9.9 ) ( 10.0 ) ( 9.9 ) ( Outdoor unit power consumption (kW) 2.810 0.680 - 3.120 2.600 0.700 - 3.010 2.610 0.690 - 2.990 2.720 0.680 - 3.040 2.890 0.670 - 3.140 2.690 0.680 - 3.170 2.800 0.660 - 3.140 2.970 0.660 - 3.170 2.970 0.660 - 3.170 3.000 0.600 - 3.340 2.250 0.690 - 3.010 2.350 0.690 - 2.970 2.500 0.690 - 3.000 2.650 0.700 - 3.040 2.680 0.680 - 3.000 2.680 0.680 - 3.170 2.350 0.690 - 2.920 2.510 0.690 - 2.960 2.670 0.700 - 3.010 2.690 0.680 - 3.120 2.820 0.680 - 3.140 2.670 0.700 - 3.010 2.680 0.690 - 3.060 2.750 0.680 - 3.130 2.770 0.670 - 3.150 2.820 0.660 - 3.140 12.34 Power factor (%) 99 11.42 99 11.46 99 11.95 99 12.69 99 11.81 99 12.30 99 13.04 99 13.04 99 13.18 99 9.88 99 10.32 99 10.98 99 11.64 99 11.77 99 11.77 99 10.32 99 11.02 99 11.73 99 11.81 99 12.38 99 11.73 99 11.77 99 12.08 99 12.17 99 12.38 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 25+50+60 25+50+71 25+60+60 25+60+71 35+35+35 35+35+42 35+35+50 35+35+60 35+35+71 35+42+42 35+42+50 35+42+60 35+42+71 35+50+50 35+50+60 35+50+71 35+60+60 35+60+71 42+42+42 42+42+50 42+42+60 42+42+71 42+50+50 42+50+60 42+50+71 42+60+60 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 1.70 3.41 4.09 - - 1.58 3.15 4.47 - - 9.2 9.2 9.2 9.4 8.6 8.8 9.0 9.2 9.1 9.0 9.1 9.2 9.3 9.0 9.2 9.4 9.4 9.5 9.0 9.2 9.3 9.4 9.3 9.4 9.5 9.5 - 1.58 3.81 3.81 - 3.62 4.27 - - 2.87 2.87 2.87 - - 2.63 2.48 2.70 2.63 2.48 3.40 3.74 4.24 - - 2.64 3.18 3.18 - - - 2.82 4.03 - - 2.20 2.64 4.46 - - 2.22 2.11 3.33 3.17 3.01 3.33 3.81 4.28 - - 2.00 3.43 4.07 - - - 2.88 3.44 - - 2.71 2.71 3.88 - - 2.76 2.60 2.54 3.27 3.09 4.32 3.27 3.71 - 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 - 2.88 2.54 ( - 3.64 3.00 2.9 - 3.64 3.00 ( - 2.12 3.00 2.9 - 2.35 2.34 ( - 4.58 3.58 2.9 - 2.26 3.01 ( - 2.26 2.51 2.9 - 1.51 2.70 ( ( 2.9 ( 2.9 ( 2.9 ( 2.9 ( 2.9 - 2.45 2.91 4.14 - - 2.46 3.52 3.52 - - ( 2.9 ( 2.9 42 9.9 ) ( 10.0 ) ( 10.0 ) ( 10.5 ) ( 9.4 ) ( 9.6 ) ( 9.8 ) ( 9.9 ) ( 10.0 ) ( 9.8 ) ( 9.9 ) ( 10.0 ) ( 10.3 ) ( 9.9 ) ( 10.0 ) ( 10.5 ) ( 10.5 ) ( 10.8 ) ( 9.9 ) ( 10.0 ) ( 10.2 ) ( 10.5 ) ( 10.2 ) ( 10.5 ) ( 10.8 ) ( 10.8 ) ( Outdoor unit power consumption (kW) 2.800 0.660 - 3.140 2.730 0.660 - 3.170 2.730 0.660 - 3.170 2.800 0.660 - 3.330 2.550 0.720 - 3.030 2.620 0.710 - 3.070 2.690 0.700 - 3.120 2.810 0.680 - 3.140 2.740 0.680 - 3.170 2.690 0.700 - 3.120 2.750 0.690 - 3.130 2.770 0.680 - 3.150 2.760 0.670 - 3.250 2.720 0.680 - 3.140 2.730 0.660 - 3.170 2.790 0.660 - 3.330 2.790 0.660 - 3.330 2.780 0.660 - 3.430 2.750 0.690 - 3.130 2.760 0.680 - 3.140 2.760 0.670 - 3.200 2.790 0.660 - 3.330 2.760 0.670 - 3.200 2.760 0.660 - 3.310 2.810 0.660 - 3.400 2.810 0.660 - 3.400 12.30 Power factor (%) 99 11.99 99 11.99 99 12.30 99 11.20 99 11.51 99 11.81 99 12.34 99 12.03 99 11.81 99 12.08 99 12.17 99 12.12 99 11.95 99 11.99 99 12.25 99 12.25 99 12.21 99 12.08 99 12.12 99 12.12 99 12.25 99 12.12 99 12.12 99 12.34 99 12.34 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 50+50+50 50+50+60 50+50+71 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+42 22+22+35+50 22+22+35+60 22+22+35+71 22+22+42+42 22+22+42+50 22+22+42+60 22+22+42+71 22+22+50+50 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 3.13 3.13 3.13 - - 2.97 2.97 3.56 - - 9.4 9.5 9.6 7.8 7.9 8.1 8.4 8.6 9.0 9.2 8.0 8.6 8.8 8.9 9.0 9.0 8.6 8.9 9.0 9.0 9.4 9.0 9.0 9.2 9.5 9.7 - 2.81 2.81 3.98 - 1.95 1.95 1.95 - 1.91 1.91 1.91 2.17 - 1.71 1.63 1.76 1.71 1.63 1.76 1.71 1.63 2.82 3.27 3.71 4.29 - 1.48 1.48 1.48 4.76 - 2.13 1.82 2.07 2.89 - 1.74 1.74 1.98 3.34 - 1.53 1.41 1.65 1.53 1.41 1.87 1.74 1.61 3.73 4.20 4.57 2.64 - 1.62 1.62 2.57 3.09 - 3.50 1.42 2.27 3.89 - 1.38 1.38 2.19 4.45 - 1.45 1.38 1.55 1.45 1.38 2.95 2.78 2.65 2.95 3.32 3.79 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 1.42 1.55 ( - 2.64 2.44 3.7 - 1.66 1.53 ( - 1.66 1.53 2.9 - 1.82 1.65 ( - 1.57 2.13 2.9 - 1.57 1.87 ( - 1.57 1.87 2.9 - 1.95 1.76 ( ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 1.33 1.33 2.54 4.30 - 1.48 1.48 3.37 3.37 - ( 3.7 ( 3.7 43 10.8 ) ( 10.9 ) ( 11.0 ) ( 9.2 ) ( 9.2 ) ( 9.4 ) ( 9.7 ) ( 9.9 ) ( 10.1 ) ( 10.1 ) ( 9.4 ) ( 9.9 ) ( 10.1 ) ( 10.2 ) ( 10.1 ) ( 10.0 ) ( 9.9 ) ( 10.1 ) ( 10.1 ) ( 10.0 ) ( 10.5 ) ( 10.1 ) ( 10.1 ) ( 10.3 ) ( 10.5 ) ( 10.9 ) ( Outdoor unit power consumption (kW) 2.790 0.660 - 3.430 2.790 0.660 - 3.450 2.830 0.660 - 3.480 2.180 0.810 - 2.670 2.190 0.810 - 2.670 2.280 0.810 - 2.730 2.340 0.800 - 2.830 2.410 0.790 - 2.930 2.510 0.770 - 3.000 2.570 0.770 - 2.980 2.260 0.810 - 2.750 2.480 0.810 - 2.970 2.470 0.800 - 2.990 2.460 0.790 - 3.020 2.510 0.770 - 2.950 2.490 0.770 - 2.920 2.480 0.810 - 2.930 2.490 0.800 - 2.940 2.510 0.790 - 2.950 2.490 0.770 - 2.920 2.580 0.770 - 3.060 2.510 0.790 - 2.950 2.500 0.780 - 2.930 2.530 0.770 - 2.990 2.560 0.770 - 3.040 2.740 0.770 - 3.250 12.25 Power factor (%) 99 12.25 99 12.43 99 9.57 99 9.62 99 10.01 99 10.28 99 10.58 99 11.02 99 11.29 99 9.93 99 10.89 99 10.85 99 10.80 99 11.02 99 10.94 99 10.89 99 10.94 99 11.02 99 10.94 99 11.33 99 11.02 99 10.98 99 11.11 99 11.24 99 12.03 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+50+60 22+22+50+71 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+25+60 22+25+25+71 22+25+35+35 22+25+35+42 22+25+35+50 22+25+35+60 22+25+35+71 22+25+42+42 22+25+42+50 22+25+42+60 22+25+42+71 22+25+50+50 22+25+50+60 22+25+50+71 22+35+35+35 22+35+35+42 22+35+35+50 22+35+35+60 22+35+35+71 22+35+42+42 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 1.34 1.34 3.05 3.67 - 1.28 1.28 2.91 4.13 - 9.4 9.6 8.1 8.6 8.7 8.8 9.0 9.4 8.9 9.0 9.0 9.4 9.4 9.0 9.2 9.4 9.5 9.4 9.4 9.6 9.2 9.3 9.4 9.4 9.6 9.4 - 1.83 2.09 2.09 2.09 2.01 2.01 2.81 - 1.67 1.91 1.91 3.21 - 1.50 1.45 1.80 1.70 1.64 1.80 1.70 1.64 3.61 4.10 4.67 2.66 - 1.60 1.81 2.54 3.05 - 3.41 1.65 2.32 3.97 - 1.35 1.54 2.15 4.36 - 1.46 1.39 1.71 1.65 1.57 2.89 2.78 2.65 2.89 3.31 3.79 4.22 - 1.40 1.60 3.20 3.20 - 3.59 1.43 2.86 4.06 - 1.58 2.54 2.54 2.54 - 1.45 1.36 2.43 2.32 2.16 2.43 2.32 2.16 2.91 3.31 3.72 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 1.25 1.53 ( - 2.49 2.99 3.7 - 1.48 1.50 ( - 1.31 1.32 3.7 - 1.46 1.51 ( - 2.66 2.39 3.7 - 1.90 1.70 ( - 1.67 1.50 3.7 - 1.77 1.59 ( ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 1.30 2.06 2.06 4.18 - 1.47 2.33 2.80 2.80 - ( 3.7 ( 3.7 44 10.5 ) ( 10.5 ) ( 9.4 ) ( 9.9 ) ( 10.1 ) ( 10.1 ) ( 10.2 ) ( 10.5 ) ( 10.2 ) ( 10.2 ) ( 10.2 ) ( 10.5 ) ( 10.6 ) ( 10.2 ) ( 10.4 ) ( 10.6 ) ( 10.8 ) ( 10.5 ) ( 11.0 ) ( 11.0 ) ( 10.3 ) ( 10.2 ) ( 10.0 ) ( 10.5 ) ( 10.9 ) ( 10.0 ) ( Outdoor unit power consumption (kW) 2.580 0.770 - 3.060 2.550 0.770 - 3.030 2.200 0.810 - 2.750 2.480 0.810 - 2.970 2.450 0.800 - 2.960 2.430 0.790 - 2.950 2.510 0.770 - 3.000 2.580 0.770 - 3.060 2.460 0.810 - 3.020 2.480 0.810 - 3.010 2.510 0.810 - 3.000 2.600 0.770 - 3.060 2.580 0.770 - 3.100 2.510 0.810 - 3.000 2.550 0.790 - 3.030 2.590 0.770 - 3.080 2.550 0.770 - 3.130 2.600 0.770 - 3.060 2.580 0.770 - 3.210 2.530 0.770 - 3.170 2.580 0.810 - 3.040 2.590 0.800 - 2.980 2.600 0.790 - 2.920 2.580 0.770 - 3.060 2.560 0.770 - 3.170 2.600 0.790 - 2.920 11.33 Power factor (%) 99 11.20 99 9.66 99 10.89 99 10.76 99 10.67 99 11.02 99 11.33 99 10.80 99 10.89 99 11.02 99 11.42 99 11.33 99 11.02 99 11.20 99 11.37 99 11.20 99 11.42 99 11.33 99 11.11 99 11.33 99 11.37 99 11.42 99 11.33 99 11.24 99 11.42 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+35+42+50 22+35+42+60 22+35+42+71 22+35+50+50 22+35+50+60 22+42+42+42 22+42+42+50 22+42+42+60 22+42+50+50 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+25+60 25+25+25+71 25+25+35+35 25+25+35+42 25+25+35+50 25+25+35+60 25+25+35+71 25+25+42+42 25+25+42+50 25+25+42+60 25+25+42+71 25+25+50+50 25+25+50+60 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 1.39 2.21 2.65 3.15 - 1.32 2.09 2.51 3.58 - 9.4 9.5 9.6 9.6 9.6 9.4 9.5 9.6 9.6 8.6 8.6 8.9 9.0 9.1 9.4 8.8 9.1 9.2 9.4 9.6 9.2 9.3 9.5 9.6 9.4 9.6 - 1.24 1.98 2.37 4.01 2.14 3.06 3.06 - 1.26 2.01 2.87 3.44 - 1.34 1.27 2.67 2.56 2.43 2.67 2.56 2.43 2.67 3.04 3.47 2.93 - 2.15 2.15 2.15 2.15 - 2.75 1.90 1.90 3.20 - 1.80 1.80 1.80 3.60 - 1.61 1.83 1.69 1.61 1.83 1.69 1.61 2.57 4.03 4.57 2.57 3.01 - 1.70 1.70 2.39 3.41 - 3.89 1.54 2.15 4.37 - 1.72 1.72 2.88 2.88 - 1.56 1.47 1.64 1.56 1.47 2.75 2.63 2.46 3.27 3.75 4.20 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 1.54 1.64 ( - 2.51 2.27 3.7 - 1.79 1.62 ( - 1.79 1.62 3.7 - 1.90 1.69 ( - 2.93 1.95 3.7 - 2.45 1.95 ( - 1.29 1.95 3.7 - 1.34 1.39 ( ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 1.57 1.57 3.13 3.13 - 1.50 1.50 3.00 3.60 - ( 3.7 ( 3.7 45 10.3 ) ( 10.7 ) ( 11.0 ) ( 10.9 ) ( 11.0 ) ( 10.3 ) ( 10.7 ) ( 11.0 ) ( 11.0 ) ( 9.9 ) ( 9.9 ) ( 10.1 ) ( 10.1 ) ( 10.2 ) ( 10.5 ) ( 10.1 ) ( 10.2 ) ( 10.2 ) ( 10.5 ) ( 11.0 ) ( 10.2 ) ( 10.4 ) ( 10.8 ) ( 11.0 ) ( 10.5 ) ( 11.0 ) ( Outdoor unit power consumption (kW) 2.600 0.800 - 3.000 2.600 0.800 - 3.200 2.530 0.770 - 3.170 2.540 0.770 - 3.170 2.530 0.770 - 3.170 2.600 0.800 - 3.000 2.600 0.800 - 3.200 2.530 0.770 - 3.170 2.530 0.770 - 3.170 2.410 0.810 - 2.990 2.490 0.810 - 2.970 2.500 0.800 - 2.960 2.510 0.790 - 2.950 2.530 0.770 - 3.000 2.580 0.770 - 3.060 2.430 0.810 - 2.950 2.530 0.800 - 2.970 2.640 0.790 - 3.000 2.600 0.770 - 3.060 2.650 0.770 - 3.210 2.640 0.790 - 3.000 2.600 0.800 - 3.100 2.700 0.800 - 3.200 2.560 0.770 - 3.170 2.550 0.770 - 3.060 2.560 0.770 - 3.170 11.42 Power factor (%) 99 11.42 99 11.11 99 11.16 99 11.11 99 11.42 99 11.42 99 11.11 99 11.11 99 10.58 99 10.94 99 10.98 99 11.02 99 11.11 99 11.33 99 10.67 99 11.11 99 11.59 99 11.42 99 11.64 99 11.59 99 11.42 99 11.86 99 11.24 99 11.20 99 11.24 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 25+25+50+71 25+35+35+35 25+35+35+42 25+35+35+50 25+35+35+60 25+35+35+71 25+35+42+42 25+35+42+50 25+35+42+60 25+42+42+42 25+42+42+50 25+42+42+60 25+42+50+50 35+35+35+35 35+35+35+42 35+35+35+50 35+35+35+60 35+35+42+42 35+35+42+50 35+42+42+42 35+42+42+50 42+42+42+42 22+22+22+22+22 22+22+22+22+25 22+22+22+22+35 22+22+22+22+42 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.43 1.43 2.87 4.07 - 1.74 2.42 2.42 2.42 - 1.68 2.35 2.35 2.82 2.27 2.27 3.24 - 1.55 2.17 2.17 3.71 - 1.63 1.56 2.02 2.29 2.19 2.02 2.74 2.62 4.11 2.74 3.13 3.56 - 1.58 2.64 2.64 2.64 - 3.02 2.43 2.43 3.48 - 1.48 2.46 2.93 2.93 - 2.26 2.17 2.35 2.26 2.17 2.35 2.26 2.17 2.35 2.72 3.09 3.48 - 2.16 2.16 2.64 2.64 - 2.97 2.50 2.50 2.50 - 2.03 2.43 2.43 2.91 - 2.00 1.95 2.45 2.00 1.95 2.45 2.00 1.95 2.45 2.00 1.95 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 ( 3.7 - 2.10 2.45 3.7 - 2.04 2.49 ( - 2.04 2.07 3.7 - 2.04 2.07 ( - 1.46 2.35 3.7 - 2.49 2.54 ( - 2.07 2.54 3.7 - 1.48 1.50 ( - 1.62 1.45 Total ( 3.7 ( 3.7 ( 3.7 ( 3.9 ( 3.9 2.00 2.20 1.79 1.79 1.79 1.79 2.84 1.69 1.69 1.69 1.69 3.24 ( 3.9 ( 3.9 46 9.8 - 11.0 9.0 - 10.2 9.2 - 10.4 9.4 10.5 9.6 10.5 9.6 10.9 9.4 - 10.5 9.5 - 10.5 9.6 - 10.7 9.5 - 10.5 9.6 - 10.7 9.8 - 11.0 9.8 - 11.0 9.4 - 10.5 9.5 - 10.8 9.6 - 11.0 9.6 - 10.9 9.6 - 11.0 9.6 - 11.0 9.6 - 11.0 9.8 - 11.0 9.8 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.610 0.770 - 3.170 2.510 0.810 - 2.840 2.540 0.800 - 2.950 2.580 0.790 3.060 2.650 0.790 3.060 2.560 0.770 3.170 2.580 0.790 - 3.060 2.700 0.800 - 3.100 2.700 0.800 - 3.200 2.700 0.800 - 3.100 2.700 0.800 - 3.200 2.610 0.770 - 3.170 2.610 0.770 - 3.170 2.570 0.810 - 3.100 2.600 0.790 - 3.150 2.640 0.770 - 3.210 2.560 0.770 - 3.170 2.640 0.770 - 3.210 2.600 0.800 - 3.200 2.600 0.800 - 3.200 2.610 0.770 - 3.170 2.610 0.770 - 3.170 2.935 0.780 - 3.500 2.935 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 11.46 Power factor (%) 99 11.02 99 11.16 99 11.33 99 11.64 99 11.24 99 11.33 99 11.86 99 11.86 99 11.86 99 11.86 99 11.46 99 11.46 99 11.29 99 11.42 99 11.59 99 11.24 99 11.59 99 11.42 99 11.42 99 11.46 99 11.46 99 12.89 99 12.89 99 12.89 99 12.82 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+22+22+50 22+22+22+22+60 22+22+22+22+71 22+22+22+25+25 22+22+22+25+35 22+22+22+25+42 22+22+22+25+50 22+22+22+25+60 22+22+22+25+71 22+22+22+35+35 22+22+22+35+42 22+22+22+35+50 22+22+22+35+60 22+22+22+35+71 22+22+22+42+42 22+22+22+42+50 22+22+22+42+60 22+22+25+25+25 22+22+25+25+35 22+22+25+25+42 22+22+25+25+50 22+22+25+25+60 22+22+25+25+71 22+22+25+35+35 22+22+25+35+42 22+22+25+35+50 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.59 1.59 1.59 1.59 3.64 1.49 1.49 1.49 1.49 4.04 1.38 1.38 1.38 1.38 1.90 1.90 2.15 2.15 1.75 1.75 1.75 1.97 2.78 1.56 1.46 1.65 1.56 1.46 1.65 1.56 1.46 1.88 1.77 1.66 1.54 4.38 1.62 1.62 1.62 2.57 2.57 2.45 1.46 1.46 2.32 3.30 1.37 1.37 1.37 2.17 3.72 1.46 1.39 1.28 1.46 1.39 1.28 1.46 1.39 2.03 2.81 2.66 2.50 3.57 1.85 1.85 2.10 2.10 2.10 1.94 1.61 1.84 1.84 3.10 1.53 1.53 1.74 1.74 3.46 1.33 1.58 1.43 1.33 1.58 1.62 1.52 1.80 1.62 1.52 2.52 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 2.70 1.61 1.43 3.9 3.17 1.31 1.94 ( 2.81 1.31 1.71 3.9 4.13 1.31 1.71 ( 2.96 1.46 1.28 3.9 3.96 1.36 1.53 ( 3.55 1.36 1.53 3.9 3.17 1.36 1.53 ( 4.48 1.90 1.65 Total ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 3.90 4.30 2.52 1.50 1.50 1.71 2.40 2.89 1.43 1.43 1.62 2.27 3.25 ( 3.9 ( 3.9 47 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.915 0.790 - 3.490 2.905 0.800 - 3.480 2.905 0.800 - 3.480 2.935 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.800 - 3.480 2.905 0.800 - 3.480 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.800 - 3.480 2.905 0.780 - 3.500 2.915 0.790 - 3.490 2.900 0.800 - 3.500 2.900 0.800 - 3.500 2.935 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.800 - 3.480 2.905 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 12.80 Power factor (%) 99 12.76 99 12.76 99 12.89 99 12.89 99 12.82 99 12.80 99 12.76 99 12.76 99 12.89 99 12.82 99 12.80 99 12.76 99 12.76 99 12.80 99 12.74 99 12.74 99 12.89 99 12.89 99 12.82 99 12.80 99 12.76 99 12.76 99 12.89 99 12.82 99 12.80 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+25+35+60 22+22+25+42+42 22+22+25+42+50 22+22+25+42+60 22+22+35+35+35 22+22+35+35+42 22+22+35+35+50 22+22+35+42+42 22+22+35+42+50 22+22+42+42+42 22+25+25+25+25 22+25+25+25+35 22+25+25+25+42 22+25+25+25+50 22+25+25+25+60 22+25+25+25+71 22+25+25+35+35 22+25+25+35+42 22+25+25+35+50 22+25+25+35+60 22+25+25+42+42 22+25+25+42+50 22+25+35+35+35 22+25+35+35+42 22+25+35+35+50 22+25+35+42+42 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.34 1.34 1.53 2.13 3.66 1.43 1.43 1.64 2.75 2.75 1.36 1.36 1.55 2.60 1.28 1.46 2.45 3.53 1.47 1.48 2.35 2.35 2.35 1.34 1.35 1.41 1.34 1.35 2.24 2.13 2.14 2.24 2.13 2.58 2.47 2.92 1.28 1.28 2.48 2.48 2.48 2.05 1.89 1.89 1.89 2.66 1.58 1.80 1.80 1.80 3.02 1.40 1.30 1.70 1.59 1.49 1.70 1.59 1.49 1.70 1.59 1.49 2.46 2.46 1.47 1.68 1.68 2.35 2.82 2.23 1.50 1.50 2.10 3.59 1.42 1.60 1.60 2.69 2.69 1.46 1.39 1.52 1.64 1.57 1.52 2.30 2.20 2.56 2.30 2.20 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 3.19 1.31 1.35 3.9 4.23 1.76 1.59 ( 3.83 1.76 1.59 3.9 3.40 1.56 1.40 ( 2.05 1.67 1.50 3.9 2.58 2.05 2.05 ( 3.06 1.28 2.05 3.9 2.70 1.28 1.80 ( 3.13 1.28 1.41 Total ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 3.05 2.30 2.64 1.32 1.49 2.10 2.10 2.99 1.32 1.51 2.11 2.53 2.53 ( 3.9 ( 3.9 48 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.905 0.780 - 3.500 2.915 0.790 - 3.490 2.900 0.800 - 3.500 2.900 0.800 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.500 2.905 0.780 - 3.500 2.900 0.800 - 3.500 2.900 0.800 - 3.500 2.900 0.800 - 3.500 2.935 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.800 - 3.480 2.905 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.780 - 3.500 2.915 0.790 - 3.490 2.905 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.500 2.905 0.780 - 3.500 2.905 0.780 - 3.500 12.76 Power factor (%) 99 12.80 99 12.74 99 12.74 99 12.89 99 12.82 99 12.76 99 12.74 99 12.74 99 12.74 99 12.89 99 12.89 99 12.82 99 12.80 99 12.76 99 12.76 99 12.89 99 12.82 99 12.80 99 12.76 99 12.80 99 12.76 99 12.89 99 12.82 99 12.76 99 12.76 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+35+35+35+35 22+35+35+35+42 25+25+25+25+25 25+25+25+25+35 25+25+25+25+42 25+25+25+25+50 25+25+25+25+60 25+25+25+25+71 25+25+25+35+35 25+25+25+35+42 25+25+25+35+50 25+25+25+35+60 25+25+25+42+42 25+25+25+42+50 25+25+35+35+35 25+25+35+35+42 25+25+35+35+50 25+25+35+42+42 Cooling capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.36 2.16 2.16 2.16 2.16 1.30 2.07 2.07 2.07 2.49 2.00 2.00 2.00 2.00 1.85 1.85 1.85 2.60 1.76 1.76 1.76 1.76 2.96 1.56 1.46 1.67 1.56 1.46 1.67 1.56 1.46 1.67 1.56 1.46 2.42 2.42 1.64 1.64 1.64 2.30 2.78 2.19 1.47 1.47 2.06 3.53 1.56 1.56 1.56 2.66 2.66 1.61 1.54 1.50 1.61 1.54 1.50 2.26 2.16 2.52 2.26 2.16 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 3.13 1.47 1.49 3.9 4.16 1.72 1.56 ( 3.76 1.72 1.56 3.9 3.32 1.72 1.56 ( 2.00 1.85 1.67 Total ( 3.9 ( 3.9 ( 3.9 ( 3.9 ( 3.9 2.99 2.26 2.60 1.47 1.47 2.06 2.06 2.94 1.48 1.48 2.07 2.48 2.49 ( 3.9 ( 3.9 49 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 10.0 - 11.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.920 0.780 - 3.500 2.905 0.780 - 3.500 2.935 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.780 - 3.500 2.905 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.500 2.905 0.780 - 3.500 2.905 0.780 - 3.500 2.905 0.780 - 3.500 2.905 0.780 - 3.500 2.935 0.780 - 3.500 2.920 0.780 - 3.490 2.915 0.790 - 3.490 2.905 0.780 - 3.500 12.82 Power factor (%) 99 12.76 99 12.89 99 12.89 99 12.82 99 12.80 99 12.76 99 12.76 99 12.89 99 12.82 99 12.76 99 12.76 99 12.76 99 12.76 99 12.89 99 12.82 99 12.80 99 12.76 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22 25 35 42 50 60 71 22+22 22+25 22+35 22+42 22+50 22+60 22+71 25+25 25+35 25+42 25+50 25+60 25+71 35+35 35+42 35+50 35+60 35+71 42+42 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E Total 3.30 - - - - 3.60 - - - - 3.3 3.6 4.0 5.4 7.2 7.9 8.6 6.6 6.9 7.3 8.1 4.00 - - - - - - - 7.20 - - - - 8.60 3.30 3.30 - - - 2.82 4.48 - - - - 6.18 - - - 2.68 7.32 - - - 3.60 3.17 7.63 3.60 4.43 - - - 3.00 6.00 - - - - 7.77 - - - 4.00 4.00 - - - 4.32 3.87 5.07 6.18 6.63 - - 1.4 ( 1.4 ( 1.6 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 - 2.73 4.23 ( - - - 1.3 - 5.20 7.41 ( - 3.10 3.09 1.2 - 2.72 2.37 ( - - - 1.2 - 3.67 5.32 ( - 3.23 2.78 1.2 - 5.40 7.90 ( ( 1.8 ( 1.8 ( 1.8 ( 1.8 ( 1.8 - 3.50 7.10 - - - 5.25 5.25 - - - ( 1.8 ( 1.8 50 4.6 ) ( 5.0 ) ( 5.3 ) ( 6.8 ) ( 8.2 ) ( 8.6 ) ( 9.2 ) ( 7.2 ) ( 8.7 ) ( 9.2 ) ( 9.9 ) ( 8.9 - 10.5 10.0 - 10.5 10.0 - 10.5 7.2 9.1 7.6 9.5 8.3 9.8 9.0 - 10.1 10.5 - 11.2 10.5 - 11.3 8.0 9.8 9.3 - 10.5 10.5 - 11.0 10.5 - 11.1 10.6 - 11.4 10.5 - 11.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 1.050 0.340 - 1.590 1.110 0.340 - 1.740 1.210 0.330 - 1.810 1.740 0.330 - 2.260 2.270 0.330 - 2.710 2.700 0.330 - 3.060 3.220 0.360 - 3.520 2.020 0.480 - 2.760 2.120 0.480 - 3.000 2.130 0.480 - 3.110 2.300 0.470 - 3.230 2.470 0.460 - 3.360 2.900 0.460 - 3.360 2.900 0.460 - 3.360 2.170 0.480 - 3.140 2.210 0.480 - 3.230 2.360 0.470 - 3.240 2.520 0.460 - 3.260 3.390 0.460 - 3.660 3.390 0.460 - 3.690 2.370 0.480 - 3.230 2.770 0.470 - 3.400 3.180 0.460 - 3.580 3.180 0.460 - 3.610 3.210 0.460 - 3.690 3.180 0.460 - 3.580 4.61 Power factor (%) 99 4.87 99 5.31 99 7.64 99 9.97 99 11.86 99 14.14 99 8.87 99 9.31 99 9.35 99 10.10 99 10.85 99 12.74 99 12.74 99 9.53 99 9.71 99 10.36 99 11.07 99 14.89 99 14.89 99 10.41 99 12.17 99 13.97 99 13.97 99 14.10 99 13.97 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 42+50 42+60 42+71 50+50 50+60 50+71 60+60 60+71 71+71 22+22+22 22+22+25 22+22+35 22+22+42 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+42 22+25+50 22+25+60 22+25+71 22+35+35 22+35+42 22+35+50 22+35+60 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 4.79 5.71 - - - 4.36 6.24 - - - 3.94 6.66 - - 5.30 - - - 4.82 5.78 - - - 5.30 4.85 6.22 5.30 5.75 - - - 2.90 2.90 2.90 - - - 2.78 4.44 - - 2.68 2.68 5.14 - - 2.33 2.10 2.57 2.33 2.10 5.86 6.35 6.80 - - 2.68 3.05 4.27 - - - 2.84 5.67 - - 2.26 2.57 6.17 - - 2.52 2.40 2.33 3.99 3.82 6.62 3.99 4.58 - ( 1.9 ( 1.9 ( 1.9 ( 1.9 ( 1.9 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 - 2.49 2.05 1.9 - 3.09 4.96 ( - 3.09 2.95 1.9 - 2.72 2.59 ( - 2.78 2.57 1.8 - - 3.19 ( - 5.30 2.81 1.8 - 5.30 2.80 ( - 5.30 4.38 Total ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.7 - 2.26 3.60 5.14 - - 2.07 3.29 5.64 - - ( 2.7 ( 2.7 51 10.5 - 11.1 10.6 - 11.3 10.6 - 11.7 10.6 - 11.9 10.6 - 11.9 10.6 - 12.0 10.6 - 12.0 10.6 - 12.1 10.6 - 12.2 8.7 - 10.6 8.8 - 11.1 10.0 - 12.6 10.5 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 8.9 - 12.6 10.0 - 12.6 10.5 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 10.5 - 12.6 10.8 - 12.6 11.0 - 12.6 11.0 - 12.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 3.180 0.460 - 3.590 3.190 0.460 - 3.650 3.090 0.450 - 3.780 2.980 0.440 - 3.770 2.980 0.440 - 3.770 2.980 0.440 - 3.870 2.980 0.440 - 3.870 2.980 0.440 - 3.910 2.980 0.440 - 3.960 2.150 0.530 - 3.060 2.170 0.530 - 3.330 2.810 0.530 - 3.710 2.850 0.520 - 3.530 2.900 0.510 - 3.350 2.890 0.510 - 3.340 2.890 0.510 - 3.340 2.170 0.530 - 3.420 2.750 0.530 - 3.700 2.810 0.520 - 3.520 2.880 0.510 - 3.340 2.870 0.510 - 3.330 2.870 0.510 - 3.330 2.970 0.530 - 3.700 2.920 0.520 - 3.510 2.870 0.510 - 3.330 2.860 0.510 - 3.320 13.97 Power factor (%) 99 14.01 99 13.57 99 13.09 99 13.09 99 13.09 99 13.09 99 13.09 99 13.09 99 9.44 99 9.53 99 12.34 99 12.52 99 12.74 99 12.69 99 12.69 99 9.53 99 12.08 99 12.34 99 12.65 99 12.60 99 12.60 99 13.04 99 12.82 99 12.60 99 12.56 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+35+71 22+42+42 22+42+50 22+42+60 22+42+71 22+50+50 22+50+60 22+50+71 22+60+60 22+60+71 25+25+25 25+25+35 25+25+42 25+25+50 25+25+60 25+25+71 25+35+35 25+35+42 25+35+50 25+35+60 25+35+71 25+42+42 25+42+50 25+42+60 25+42+71 25+50+50 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.89 3.01 6.10 - - 2.28 4.36 4.36 - - 2.12 4.06 4.82 - 3.73 5.32 - - 1.79 3.42 5.79 - - 1.83 1.69 4.51 4.17 3.85 4.51 5.00 5.46 - - 1.58 4.31 5.11 - - - 2.97 4.16 - - 2.88 2.88 4.84 - - 2.50 2.27 2.75 2.50 2.27 5.50 6.00 6.46 - - 2.65 3.70 4.45 - - - 3.21 5.50 - - 2.10 2.94 5.96 - - 2.35 2.16 4.24 3.95 3.64 4.24 4.70 5.20 - ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.6 ( 2.7 ( 2.7 - 2.29 2.52 2.7 - 3.87 5.00 ( - 3.87 3.50 2.7 - 2.76 2.50 ( - 2.97 2.75 2.7 - 4.65 3.00 ( - 4.65 3.00 2.7 - 1.70 3.00 ( - 1.95 1.98 Total ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 - 1.99 3.35 5.66 - - 2.20 4.40 4.40 - - ( 2.7 ( 2.7 52 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 9.0 - 12.6 10.1 - 12.6 10.6 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 10.5 - 12.6 10.8 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.860 0.510 - 3.320 2.870 0.510 - 3.330 2.860 0.510 - 3.320 2.860 0.510 - 3.320 2.780 0.500 - 3.350 2.720 0.490 - 3.270 2.710 0.490 - 3.390 2.710 0.490 - 3.380 2.710 0.490 - 3.380 2.710 0.490 - 3.380 2.170 0.530 - 3.750 2.480 0.530 - 3.750 2.670 0.520 - 3.600 2.870 0.510 - 3.450 2.860 0.510 - 3.440 2.860 0.510 - 3.440 2.890 0.530 - 3.700 2.720 0.520 - 3.570 2.550 0.510 - 3.440 2.860 0.510 - 3.430 2.850 0.510 - 3.260 2.550 0.510 - 3.440 2.700 0.510 - 3.430 2.850 0.510 - 3.340 2.770 0.500 - 3.250 2.700 0.490 - 3.260 12.56 Power factor (%) 99 12.60 99 12.56 99 12.56 99 12.21 99 11.95 99 11.90 99 11.90 99 11.90 99 11.90 99 9.53 99 10.89 99 11.73 99 12.60 99 12.56 99 12.56 99 12.69 99 11.95 99 11.20 99 12.56 99 12.52 99 11.20 99 11.86 99 12.52 99 12.17 99 11.86 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 25+50+60 25+50+71 25+60+60 25+60+71 35+35+35 35+35+42 35+35+50 35+35+60 35+35+71 35+42+42 35+42+50 35+42+60 35+42+71 35+50+50 35+50+60 35+50+71 35+60+60 35+60+71 42+42+42 42+42+50 42+42+60 42+42+71 42+50+50 42+50+60 42+50+71 42+60+60 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 2.04 4.07 4.89 - - 1.88 3.77 5.35 - - 1.90 4.55 4.55 - 4.23 5.01 - - 3.33 3.33 3.33 - - 3.21 2.96 3.28 3.21 2.96 3.94 4.58 5.08 - - 3.24 3.88 3.88 - - - 3.37 4.82 - - 2.60 3.12 5.28 - - 2.66 2.46 4.07 3.79 3.53 4.07 4.55 5.01 - - 2.32 3.98 4.70 - - - 3.45 4.10 - - 3.21 3.21 4.58 - - 3.26 3.04 2.98 3.87 3.62 5.04 3.87 4.34 - ( 2.6 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 - 3.45 2.98 2.7 - 4.26 3.60 ( - 4.26 3.60 2.7 - 2.48 3.60 ( - 2.81 2.86 2.7 - 5.54 4.33 ( - 2.73 3.64 2.7 - 2.73 3.03 ( - 1.76 3.28 Total ( 2.7 ( 2.7 ( 2.7 ( 2.7 ( 2.7 - 2.83 3.38 4.79 - - 2.86 4.07 4.07 - - ( 2.7 ( 2.7 53 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 10.0 - 12.6 10.5 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 10.8 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.700 0.490 - 3.380 2.700 0.490 - 3.250 2.700 0.490 - 3.250 2.700 0.490 - 3.250 2.730 0.530 - 3.700 2.790 0.520 - 3.560 2.850 0.510 - 3.430 2.850 0.510 - 3.430 2.850 0.510 - 3.430 2.850 0.510 - 3.430 2.850 0.510 - 3.430 2.850 0.510 - 3.430 2.770 0.500 - 3.340 2.700 0.490 - 3.250 2.700 0.490 - 3.250 2.700 0.490 - 3.250 2.700 0.490 - 3.250 2.700 0.490 - 3.250 2.850 0.510 - 3.430 2.850 0.510 - 3.430 2.810 0.500 - 3.380 2.700 0.490 - 3.250 2.810 0.500 - 3.380 2.690 0.490 - 3.240 2.690 0.490 - 3.240 2.690 0.490 - 3.240 11.86 Power factor (%) 99 11.86 99 11.86 99 11.86 99 11.99 99 12.25 99 12.52 99 12.52 99 12.52 99 12.52 99 12.52 99 12.52 99 12.17 99 11.86 99 11.86 99 11.86 99 11.86 99 11.86 99 12.52 99 12.52 99 12.34 99 11.86 99 12.34 99 11.81 99 11.81 99 11.81 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 50+50+50 50+50+60 50+50+71 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+42 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+42 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+42 22+22+35+50 22+22+35+60 22+22+35+71 22+22+42+42 22+22+42+50 22+22+42+60 22+22+42+71 22+22+50+50 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 3.67 3.67 3.67 - - 3.43 3.44 4.13 - - 3.22 3.22 4.56 - 2.50 2.50 2.50 - 2.42 2.42 2.42 2.74 - 2.20 2.09 2.29 2.20 2.09 2.29 2.20 2.09 3.64 4.20 4.73 5.24 - 1.77 1.77 1.77 5.69 - 2.66 2.22 2.52 3.54 - 2.14 2.14 2.43 4.09 - 1.88 1.73 2.03 1.88 1.73 2.31 2.13 1.96 4.63 5.11 5.58 3.22 - 1.96 1.96 3.12 3.76 - 4.26 1.74 2.77 4.75 - 1.61 1.61 2.57 5.21 - 1.78 1.66 1.89 1.78 1.66 3.61 3.40 3.16 3.61 4.04 4.52 ( 3.4 ( 3.4 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.4 ( 3.4 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.4 ( 3.5 ( 3.5 - 1.74 1.89 3.4 - 3.22 2.98 ( - 2.03 1.88 2.7 - 2.03 1.88 ( - 2.22 2.03 2.7 - 1.92 2.66 ( - 1.92 2.34 2.7 - 1.92 2.34 ( - 2.50 2.29 Total ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 - 1.54 1.54 2.94 4.98 - 1.68 1.68 3.82 3.82 - ( 3.5 ( 3.4 54 11.0 - 12.6 11.0 - 12.6 11.0 - 12.6 10.0 - 13.3 10.0 - 13.3 10.5 - 13.3 10.8 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 10.0 - 13.3 10.5 - 13.3 10.8 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 10.5 - 13.3 10.8 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.700 0.490 - 3.250 2.690 0.490 - 3.240 2.690 0.490 - 3.240 2.180 0.590 - 3.900 2.170 0.590 - 3.900 2.290 0.590 - 3.900 2.340 0.580 - 3.890 2.390 0.580 - 3.890 2.380 0.580 - 3.880 2.380 0.580 - 3.880 2.160 0.590 - 3.900 2.280 0.590 - 3.900 2.330 0.580 - 3.890 2.380 0.580 - 3.890 2.370 0.580 - 3.880 2.370 0.580 - 3.880 2.280 0.590 - 3.900 2.320 0.580 - 3.890 2.370 0.580 - 3.890 2.360 0.580 - 3.880 2.360 0.580 - 3.880 2.370 0.580 - 3.890 2.360 0.580 - 3.880 2.360 0.580 - 3.880 2.310 0.580 - 3.890 2.270 0.550 - 3.880 11.86 Power factor (%) 99 11.81 99 11.81 99 9.57 99 9.53 99 10.06 99 10.28 99 10.50 99 10.45 99 10.45 99 9.49 99 10.01 99 10.23 99 10.45 99 10.41 99 10.41 99 10.01 99 10.19 99 10.41 99 10.36 99 10.36 99 10.41 99 10.36 99 10.36 99 10.14 99 9.97 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+50+60 22+22+50+71 22+25+25+25 22+25+25+35 22+25+25+42 22+25+25+50 22+25+25+60 22+25+25+71 22+25+35+35 22+25+35+42 22+25+35+50 22+25+35+60 22+25+35+71 22+25+42+42 22+25+42+50 22+25+42+60 22+25+42+71 22+25+50+50 22+25+50+60 22+25+50+71 22+35+35+35 22+35+35+42 22+35+35+50 22+35+35+60 22+35+35+71 22+35+42+42 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.57 1.57 3.57 4.29 - 1.47 1.47 3.33 4.73 - 2.37 2.71 2.71 2.71 2.45 2.45 3.44 - 2.08 2.37 2.37 3.98 - 1.83 1.69 2.25 2.08 1.92 2.25 2.08 1.92 4.52 5.01 5.47 3.29 - 1.95 2.22 3.10 3.73 - 4.17 1.94 2.71 4.65 - 1.58 1.80 2.52 5.10 - 1.74 1.62 2.10 1.98 1.85 3.53 3.32 3.10 3.53 3.96 4.43 4.88 - 1.65 1.87 3.74 3.74 - 4.21 1.64 3.27 4.65 - 1.91 3.03 3.03 3.03 - 1.70 1.59 2.87 2.71 2.53 2.87 2.71 2.53 3.45 3.88 4.35 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.4 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 - 1.44 1.81 3.4 - 2.89 3.50 ( - 1.72 1.75 3.4 - 1.51 1.54 ( - 1.70 1.84 3.5 - 3.29 2.92 ( - 2.35 2.08 3.5 - 2.07 1.83 ( - 2.16 1.98 Total ( 3.5 ( 3.4 ( 3.5 ( 3.5 ( 3.5 - 1.48 2.36 2.36 4.80 - 1.71 2.73 3.28 3.28 - ( 3.5 ( 3.5 55 11.0 - 13.3 11.0 - 13.3 10.5 - 13.3 10.5 - 13.3 10.8 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.260 0.580 - 3.870 2.260 0.580 - 3.900 2.290 0.590 - 3.900 2.280 0.590 - 3.900 2.330 0.580 - 3.890 2.380 0.580 - 3.890 2.360 0.580 - 3.880 2.360 0.580 - 3.880 2.520 0.590 - 3.900 2.430 0.580 - 3.890 2.350 0.580 - 3.890 2.340 0.580 - 3.880 2.340 0.580 - 3.880 2.350 0.580 - 3.890 2.340 0.580 - 3.880 2.340 0.580 - 3.880 2.290 0.580 - 3.890 2.260 0.580 - 3.880 2.250 0.580 - 3.870 2.250 0.580 - 3.900 2.550 0.590 - 3.900 2.450 0.580 - 3.890 2.350 0.580 - 3.890 2.340 0.580 - 3.880 2.340 0.580 - 3.900 2.350 0.580 - 3.890 9.93 Power factor (%) 99 9.93 99 10.06 99 10.01 99 10.23 99 10.45 99 10.36 99 10.36 99 11.07 99 10.67 99 10.32 99 10.28 99 10.28 99 10.32 99 10.28 99 10.28 99 10.06 99 9.93 99 9.88 99 9.88 99 11.20 99 10.76 99 10.32 99 10.28 99 10.28 99 10.32 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+35+42+50 22+35+42+60 22+35+42+71 22+35+50+50 22+35+50+60 22+42+42+42 22+42+42+50 22+42+42+60 22+42+50+50 25+25+25+25 25+25+25+35 25+25+25+42 25+25+25+50 25+25+25+60 25+25+25+71 25+25+35+35 25+25+35+42 25+25+35+50 25+25+35+60 25+25+35+71 25+25+42+42 25+25+42+50 25+25+42+60 25+25+42+71 25+25+50+50 25+25+50+60 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.61 2.59 3.10 3.69 - 1.52 2.42 2.91 4.15 - 1.42 2.27 2.72 4.59 2.45 3.50 3.51 - 1.45 2.31 3.29 3.95 - 1.55 1.46 3.12 2.96 2.79 3.12 2.96 2.79 3.12 3.53 3.96 3.35 - 2.50 2.50 2.50 2.50 - 3.19 2.24 2.24 3.78 - 2.20 2.20 2.20 4.40 - 1.88 2.29 2.04 1.88 2.29 2.04 1.88 3.21 4.88 5.36 3.21 3.65 - 2.04 2.04 2.85 4.07 - 4.54 1.76 2.47 5.01 - 2.05 2.05 3.45 3.45 - 1.81 1.68 1.93 1.81 1.68 3.25 3.04 2.83 3.88 4.34 4.80 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.4 ( 3.4 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.4 ( 3.5 ( 3.5 ( 3.5 - 1.76 1.93 3.5 - 3.03 2.66 ( - 2.16 1.90 3.5 - 2.16 1.90 ( - 2.24 2.04 3.5 - 3.35 2.27 ( - 2.82 2.27 3.5 - 1.48 2.27 ( - 1.54 7.88 Total ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 - 1.83 1.83 3.67 3.67 - 1.72 1.72 3.44 4.12 - ( 3.5 ( 3.5 56 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 17.2 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 10.0 - 13.3 10.0 - 13.3 10.5 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.400 0.600 - 3.900 2.300 0.600 - 3.900 2.250 0.580 - 3.900 2.240 0.580 - 3.880 2.250 0.580 - 3.900 2.400 0.600 - 3.900 2.300 0.600 - 3.900 2.250 0.580 - 3.900 2.250 0.580 - 3.900 2.160 0.590 - 3.900 2.150 0.590 - 3.900 2.250 0.580 - 3.890 2.360 0.580 - 3.890 2.350 0.580 - 3.880 2.350 0.580 - 3.880 2.550 0.590 - 3.900 2.440 0.580 - 3.890 2.330 0.580 - 3.890 2.300 0.580 - 3.880 2.300 0.580 - 3.880 2.330 0.580 - 3.890 2.300 0.600 - 3.900 2.300 0.600 - 3.900 2.240 0.580 - 3.880 2.250 0.580 - 3.880 2.240 0.580 - 3.880 10.54 Power factor (%) 99 10.10 99 9.88 99 9.84 99 9.88 99 10.54 99 10.10 99 9.88 99 9.88 99 9.49 99 9.44 99 9.88 99 10.36 99 10.32 99 10.32 99 11.20 99 10.72 99 10.23 99 10.10 99 10.10 99 10.23 99 10.10 99 10.10 99 9.84 99 9.88 99 9.84 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 25+25+50+71 25+35+35+35 25+35+35+42 25+35+35+50 25+35+35+60 25+35+35+71 25+35+42+42 25+35+42+50 25+35+42+60 25+42+42+42 25+42+42+50 25+42+42+60 25+42+50+50 35+35+35+35 35+35+35+42 35+35+35+50 35+35+35+60 35+35+42+42 35+35+42+50 35+42+42+42 35+42+42+50 42+42+42+42 22+22+22+22+22 22+22+22+22+25 22+22+22+22+35 22+22+22+22+42 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.61 1.61 3.22 4.56 - 2.12 2.96 2.96 2.96 - 2.01 2.81 2.81 3.37 2.66 2.66 3.79 - 1.77 2.48 2.48 4.27 - 1.91 1.81 2.32 2.67 2.53 2.32 3.21 3.04 4.70 3.21 3.62 4.07 - 1.82 3.06 3.06 3.06 - 3.46 2.73 2.73 3.91 - 1.65 2.77 3.29 3.29 - 2.62 2.48 2.75 2.62 2.48 2.75 2.62 2.48 2.75 3.14 3.56 4.01 - 2.50 2.50 3.00 3.00 - 3.41 2.87 2.87 2.87 - 2.27 2.74 2.74 3.25 - 2.40 2.34 2.75 2.40 2.34 2.75 2.40 2.34 2.75 2.40 2.34 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.4 ( 3.5 ( 3.5 ( 3.5 ( 3.5 ( 3.5 - 2.39 2.75 3.5 - 2.33 2.85 ( - 2.33 2.37 3.5 - 2.33 2.37 ( - 1.63 2.75 3.4 - 2.85 2.91 ( - 2.38 2.91 3.5 - 1.70 1.72 ( - 1.89 1.66 Total ( 3.5 ( 3.5 ( 3.5 ( 4.1 ( 4.1 2.40 2.64 2.15 2.15 2.15 2.15 3.40 2.03 2.03 2.03 2.03 3.88 ( 4.1 ( 4.1 57 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 13.3 11.0 13.3 11.0 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 11.0 - 13.3 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.240 0.580 - 3.880 2.520 0.590 - 3.900 2.400 0.580 - 3.890 2.290 0.580 3.890 2.290 0.580 3.880 2.290 0.580 3.900 2.290 0.580 - 3.890 2.300 0.600 - 3.900 2.300 0.600 - 3.900 2.300 0.600 - 3.900 2.300 0.600 - 3.900 2.240 0.580 - 3.880 2.240 0.580 - 3.880 2.500 0.590 - 3.900 2.400 0.580 - 3.890 2.310 0.580 - 3.890 2.300 0.590 - 3.880 2.310 0.580 - 3.890 2.300 0.600 - 3.900 2.300 0.600 - 3.900 2.240 0.580 - 3.880 2.240 0.580 - 3.880 2.835 0.780 - 4.100 2.835 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 9.84 Power factor (%) 99 11.07 99 10.54 99 10.06 99 10.06 99 10.06 99 10.06 99 10.10 99 10.10 99 10.10 99 10.10 99 9.84 99 9.84 99 10.98 99 10.54 99 10.14 99 10.10 99 10.14 99 10.10 99 10.10 99 9.84 99 9.84 99 12.45 99 12.45 99 12.45 99 12.38 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+22+22+50 22+22+22+22+60 22+22+22+22+71 22+22+22+25+25 22+22+22+25+35 22+22+22+25+42 22+22+22+25+50 22+22+22+25+60 22+22+22+25+71 22+22+22+35+35 22+22+22+35+42 22+22+22+35+50 22+22+22+35+60 22+22+22+35+71 22+22+22+42+42 22+22+22+42+50 22+22+22+42+60 22+22+25+25+25 22+22+25+25+35 22+22+25+25+42 22+22+25+25+50 22+22+25+25+60 22+22+25+25+71 22+22+25+35+35 22+22+25+35+42 22+22+25+35+50 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.91 1.91 1.91 1.91 4.36 1.78 1.78 1.78 1.78 4.88 1.66 1.66 1.66 1.66 2.28 2.28 2.58 2.58 2.10 2.10 2.10 2.38 3.32 1.87 1.75 1.98 1.87 1.75 1.98 1.87 1.75 2.26 2.13 1.99 1.85 5.26 1.94 1.94 1.94 3.09 3.09 2.94 1.75 1.75 2.78 3.97 1.64 1.64 1.64 2.61 4.47 1.76 1.67 1.53 1.76 1.67 1.53 1.76 1.67 2.44 3.36 3.19 3.00 4.29 2.22 2.22 2.52 2.52 2.52 2.33 1.94 2.20 2.20 3.72 1.83 1.83 2.08 2.08 4.18 1.60 1.90 1.71 1.60 1.90 1.95 1.82 2.16 1.95 1.82 3.02 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 3.26 1.94 1.71 4.1 3.80 1.57 2.33 ( 3.36 1.57 2.04 4.1 4.97 1.57 2.04 ( 3.54 1.75 1.53 4.1 4.76 1.63 1.84 ( 4.26 1.63 1.84 4.1 3.80 1.63 1.84 ( 5.36 2.28 1.98 Total ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 4.68 5.16 3.02 1.81 1.81 2.05 2.88 3.45 1.71 1.71 1.95 2.73 3.90 ( 4.1 ( 4.1 58 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.815 0.790 - 4.080 2.805 0.800 - 4.070 2.805 0.800 - 4.070 2.835 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.800 - 4.070 2.805 0.800 - 4.070 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.800 - 4.070 2.805 0.780 - 4.100 2.815 0.790 - 4.080 2.800 0.800 - 4.100 2.800 0.800 - 4.100 2.835 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.800 - 4.070 2.805 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 12.36 Power factor (%) 99 12.32 99 12.32 99 12.45 99 12.45 99 12.38 99 12.36 99 12.32 99 12.32 99 12.45 99 12.38 99 12.36 99 12.32 99 12.32 99 12.36 99 12.30 99 12.30 99 12.45 99 12.45 99 12.38 99 12.36 99 12.32 99 12.32 99 12.45 99 12.38 99 12.36 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+22+25+35+60 22+22+25+42+42 22+22+25+42+50 22+22+25+42+60 22+22+35+35+35 22+22+35+35+42 22+22+35+35+50 22+22+35+42+42 22+22+35+42+50 22+22+42+42+42 22+25+25+25+25 22+25+25+25+35 22+25+25+25+42 22+25+25+25+50 22+25+25+25+60 22+25+25+25+71 22+25+25+35+35 22+25+25+35+42 22+25+25+35+50 22+25+25+35+60 22+25+25+42+42 22+25+25+42+50 22+25+35+35+35 22+25+35+35+42 22+25+35+35+50 22+25+35+42+42 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.14 1.14 1.29 4.04 4.39 1.72 1.72 1.96 3.30 3.30 1.64 1.64 1.86 3.13 1.54 1.75 2.94 4.23 1.77 1.77 2.82 2.82 2.82 1.61 1.62 1.69 1.61 1.62 2.69 2.56 2.58 2.69 2.56 3.09 2.95 3.52 1.56 1.56 2.96 2.96 2.96 2.46 2.27 2.27 2.27 3.19 1.89 2.16 2.16 2.16 3.63 1.68 1.57 2.04 1.91 1.79 2.04 1.91 1.79 2.04 1.91 1.79 2.96 2.96 1.78 2.01 2.01 2.82 3.38 2.68 1.80 1.80 2.51 4.31 1.70 1.92 1.92 3.23 3.23 1.75 1.66 1.83 1.97 1.89 1.83 2.76 2.64 3.07 2.76 2.64 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 3.82 1.58 1.61 4.1 5.06 2.11 1.91 ( 4.59 2.11 1.91 4.1 4.08 1.86 1.68 ( 2.46 2.00 1.80 4.1 3.09 2.45 2.46 ( 3.66 1.54 2.46 4.1 3.24 1.54 2.16 ( 3.73 1.54 1.69 Total ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 3.66 2.76 3.17 1.68 1.68 2.52 2.52 3.60 1.59 1.80 2.53 3.04 3.04 ( 4.1 ( 4.1 59 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.805 0.780 - 4.100 2.815 0.790 - 4.080 2.800 0.800 - 4.100 2.800 0.800 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.100 2.805 0.780 - 4.100 2.800 0.800 - 4.100 2.800 0.800 - 4.100 2.800 0.800 - 4.100 2.835 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.800 - 4.070 2.805 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.780 - 4.100 2.815 0.790 - 4.080 2.805 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.100 2.805 0.780 - 4.100 2.805 0.780 - 4.100 12.32 Power factor (%) 99 12.36 99 12.30 99 12.30 99 12.45 99 12.38 99 12.32 99 12.30 99 12.30 99 12.30 99 12.45 99 12.45 99 12.38 99 12.36 99 12.32 99 12.32 99 12.45 99 12.38 99 12.36 99 12.32 99 12.36 99 12.32 99 12.45 99 12.38 99 12.32 99 12.32 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Indoor units combination 22+35+35+35+35 22+35+35+35+42 25+25+25+25+25 25+25+25+25+35 25+25+25+25+42 25+25+25+25+50 25+25+25+25+60 25+25+25+25+71 25+25+25+35+35 25+25+25+35+42 25+25+25+35+50 25+25+25+35+60 25+25+25+42+42 25+25+25+42+50 25+25+35+35+35 25+25+35+35+42 25+25+35+35+50 25+25+35+42+42 Heating capacity (kW) Unit A Unit B Unit C Unit D Unit E 1.64 2.59 2.59 2.59 2.59 1.55 2.49 2.49 2.49 2.98 2.40 2.40 2.40 2.40 2.22 2.22 2.22 3.12 2.11 2.11 2.11 2.11 3.56 1.88 1.75 2.00 1.88 1.75 2.00 1.88 1.75 2.00 1.88 1.75 2.90 2.90 1.97 1.97 1.97 2.76 3.33 2.63 1.76 1.76 2.47 4.25 1.88 1.88 1.88 3.18 3.18 1.94 1.85 1.79 1.94 1.85 1.79 2.71 2.59 3.03 2.71 2.59 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 3.76 1.76 1.79 4.1 5.00 2.07 1.87 ( 4.48 2.07 1.87 4.1 4.00 2.07 1.87 ( 2.40 2.22 2.00 Total ( 4.1 ( 4.1 ( 4.1 ( 4.1 ( 4.1 3.60 2.71 3.12 1.76 1.76 2.47 2.47 3.54 1.77 1.77 2.50 2.98 2.98 ( 4.1 ( 4.1 60 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 12.0 - 14.0 ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( Outdoor unit power consumption (kW) 2.820 0.780 - 4.100 2.805 0.780 - 4.100 2.835 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.780 - 4.100 2.805 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.100 2.805 0.780 - 4.100 2.805 0.780 - 4.100 2.805 0.780 - 4.100 2.805 0.780 - 4.100 2.835 0.780 - 4.100 2.820 0.780 - 4.090 2.815 0.790 - 4.080 2.805 0.780 - 4.100 12.38 Power factor (%) 99 12.32 99 12.45 99 12.45 99 12.38 99 12.36 99 12.32 99 12.32 99 12.45 99 12.38 99 12.32 99 12.32 99 12.32 99 12.32 99 12.45 99 12.38 99 12.36 99 12.32 99 Current (A) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) 5 SPECIFICATION Outdoor model MXZ-2A30VA Single phase 230 V, 50 Hz 2 Max. 20 Max. 15 Refer to 9 Refer to 9 Outdoor unit power supply System Indoor units number m Piping total length m Connecting pipe length m Height difference (Indoor ~ Outdoor) m Height difference (Indoor ~ Indoor) Function kW Capacity [Rated (Min.-Max.) Hz] /h Dehumidification m3 /h Outdoor air flow Breaker capacity A Running current A Power input W Power factor % Starting current A Compressor motor current A Fan motor current A Coefficient of performance(C.O.P) 2 Capacity Cooling 3.0 (1.1 - 4.0) — 1,950 10 Special remarks Fan motor Compressor 2 Electrical data 2.87 595 Output Winding resistance (at 20 °C) Model Winding resistance (at 20 °C) Dimensions W x H x D Weight Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity (R410A) Refrigeration oil (Model) 3.6 745 90 3.60 2.67 3.40 0.2 5.04 E1 Model Heating 4.0 (1.0 - 4.5) — 1,950 5.37 KNB092FEDH KNB073FGDH 750 U-V 1.70 V-W 1.70 W-U 1.70 RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2 800 x 550 x 285 34 E2 W Ω Ω mm kg dB rpm 46/44 850/650 47/46 850/650 2 kg 1.15 cc 320 (NEO22) NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m) •Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination. 1 Measured under rated operating frequency. 2 Electrical data is for only outdoor unit. 3 These specifications are when all indoor units are operating. TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C 61 MXZ-2A40VA - E1 Single phase 230 V, 50 Hz 2 Max. 30 Max. 20 Refer to 9 Refer to 9 Heating Cooling 4.5 (1.0 - 5.0) 4.0 (1.1 - 4.5) — — 1,860 1,860 15 4.32 4.78 945 1,045 95 4.78 4.12 4.58 0.2 4.76 3.83 SNB130FKCH 1,100 U-V 0.64 V-W 0.64 W-U 0.64 RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2 800 x 550 x 285 40 48/47 47/44 850/490 850/530 2 MXZ-2A40VA - E2 Single phase 230 V, 50 Hz 2 Max. 30 Max. 20 Refer to 9 Refer to 9 Heating Cooling 4.5 (1.0 - 5.0) 4.0 (1.1 - 4.5) — — 1,950 1,950 15 4.78 4.32 945 1,045 95 4.78 4.58 4.12 0.2 3.83 4.76 KNB092FEDH 1,100 U-V 1.70 V-W 1.70 W-U 1.70 RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2 800 x 550 x 285 34 47/44 48/47 850/650 850/650 2 kg 1.3 1.15 cc 450 (NEO22) 320 (NEO22) Outdoor model Outdoor unit power supply System kW /h m3 /h A A W % A A A Special remarks Fan motor Compressor 2 Electrical data m m m m Capacity Indoor units number Piping total length Connecting pipe length Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function Capacity [Rated (Min.-Max.) Hz] Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current Compressor motor current Fan motor current Coefficient of performance(C.O.P) 2 Model Output Winding resistance(at 20 °C) Model Winding resistance(at 20 °C) Dimensions W x H x D Weight Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity(R410A) Refrigeration oil (Model) W Ω Ω mm kg dB rpm NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m) •Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination. 1 Measured under rated operating frequency. 2 Electrical data is for only outdoor unit. 3 These specifications are when all indoor units are operating. TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C 62 Outdoor model Outdoor unit power supply System kW /h m3 /h A A W % A A A 2 Electrical data m m m m Capacity Indoor units number Piping total length Connecting pipe length Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function Capacity [Rated (Min.-Max.) Hz] Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current Compressor motor current Fan motor current Coefficient of performance(C.O.P) 2 MXZ-2A52VA Single phase 230 V, 50 Hz 2 Max. 30 Max. 20 Refer to 9 Refer to 9 Cooling Heating 6.4 (1.0 - 7.2) 5.2 (1.1 - 6.0) — — 1,860 1,860 15 7.64 6.75 1,705 1,505 97 7.64 7.44 6.55 0.2 3.75 3.46 E1 SNB130FKCH E2 SNB130FKMH Special remarks Fan motor Compressor Model Output W 1,400 Winding resistance(at 20 °C) Ω U-V 0.64 V-W 0.64 W-U 0.64 MXZ-3A54VA Single phase 230 V, 50 Hz 2 to 3 Max. 50 Max. 25 Refer to 9 Refer to 9 Heating Cooling 6.8 (2.6-9.0) 5.4 (2.9-6.8) — — 2,470 2,525 25 6.39 5.69 1,455 1,295 99 6.39 6.19 5.49 0.2 4.67 4.17 E1 , E2 SNB130FLDH1 SNB130FLEH1 E3 SNB130FGBH1 E4 , E5 , E6 SNB130FGBH1T E7 1,400 U-V 0.45 E1 , E2 , E3 V-W 0.45 W-U 0.45 E4 , E5 , E6 , E7 U-V 0.98 V-W 0.98 W-U 0.98 RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2 800 x 550 x 285 40 50/48 49/45 850/490 850/530 2 RC0J60-AA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2 840 x 710 x 330 57 46/44 48/47 650/510 640/510 2 kg 1.3 2.7 cc 450 (NEO22) Model Winding resistance(at 20 °C) Dimensions W x H x D Weight Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity(R410A) mm kg dB rpm Refrigeration oil (Model) Ω E1 , E2 , E3 E4 , E5 , E6 , E7 NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m) •Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination. 1 Measured under rated operating frequency. 2 Electrical data is for only outdoor unit. 3 These specifications are when all indoor units are operating. TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C 63 600 (NEO22) 700 (NEO22) Outdoor model Outdoor unit power supply System kW /h m3 /h A A W % A A A 2 Electrical data m m m m Capacity Indoor units number Piping total length Connecting pipe length Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function Capacity [Rated (Min.-Max.) Hz] Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current Compressor motor current Fan motor current Coefficient of performance(C.O.P) 2 Fan motor Compressor Model Output Winding resistance (at 20 °C) Model Winding resistance (at 20°C) Dimensions W x H x D Special remarks Weight W MXZ-4A71VA Single phase 230 V, 50 Hz 2 to 4 Max. 60 Max. 25 Refer to 9 Refer to 9 Heating Cooling 8.6 (3.4-9.0) 7.1 (3.7-8.8) — — 2,790 2,525 25 8.56 8.48 1,950 1,930 99 8.56 8.36 8.28 0.2 4.41 3.68 E1 , E2 SNB130FLDH1 E3 SNB130FLEH1 E4 , E5 , E6 SNB130FGBH1 SNB130FGBH1T E7 2,000 E1 , E2 , E3 U-V 0.45 V-W 0.45 W-U 0.45 E4 , E5 , E6 , E7 U-V 0.98 V-W 0.98 W-U 0.98 Ω mm RC0J60-AA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2 840 x 710 x 330 kg 58 Ω Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity (R410A) dB rpm Refrigeration oil (Model) cc E1 , E2 , E3 2,100 U-V 1.41 V-W 1.41 W-U 1.41 2 2.7 3.5 50/48 700/510 600 (NEO22) 700 (NEO22) E4 , E5 , E6 , E7 TNB220FMCH PM8H60-UA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2 900 x 900 x 320 70 E1 67 E2 48/46 46/44 590/400 560/400 2 48/45 650/510 kg MXZ-4A80VA Single phase 230 V, 50 Hz 2 to 4 Max. 70 Max. 25 Refer to 9 Refer to 9 Heating Cooling 9.4 (3.4-11.6) 8.0 (3.7-9.2) — — 2,630 2,530 25 8.48 9.62 1,930 2,190 99 9.62 8.28 9.42 0.2 4.87 3.65 870 (NEO22) NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m) •Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination. 1 Measured under rated operating frequency. 2 Electrical data is for only outdoor unit. 3 These specifications are when all indoor units are operating. TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C 64 MXZ-5A100VA Single phase 230 V, 50 Hz 2 to 5 Max. 80 Max. 25 Refer to 9 Refer to 9 Outdoor model Outdoor unit power supply System kW /h m3 /h A A W % A A A Special remarks Fan motor Compressor 2 Electrical data m m m m Capacity Indoor units number Piping total length Connecting pipe length Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function Capacity [Rated (Min.-Max.) Hz Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current Compressor motor current Fan motor current Coefficient of performance(C.O.P) 2 Model Output Winding resistance(at 20 °C) Model Winding resistance(at 20 °C) Dimensions W x H x D Weight Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity(R410A) Refrigeration oil (Model) Heating 12 (3.4 - 14) — 3,558 Cooling 10 (3.7 - 11) — 3,396 25 12.45 2,835 12.88 2,935 99 12.88 12.25 12.68 0.2 4.23 3.41 TNB220FMCH 2,700 U-V 1.41 V-W 1.41 W-U 1.41 PM8H60-UA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2 900 x 900 x 320 68 W Ω Ω mm kg dB rpm 54/46 700/500 51/45 700/500 2 kg 4.0 cc 870 (NEO22) NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m) •Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination. 1 Measured under rated operating frequency. 2 Electrical data is for only outdoor unit. 3 These specifications are when all indoor units are operating. TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C 65 NOISE CRITERIA CURVES 6 MXZ-2A30VA MXZ-2A40VA FAN SPEED FUNCTION SPL(dB(A)) High Cooling 46 High Cooling 47 High Heating 47 High Heating 48 OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 63 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 10 125 250 500 1000 2000 4000 63 8000 125 MXZ-2A52VA FAN SPEED FUNCTION SPL(dB(A)) 500 1000 2000 4000 LINE MXZ-3A54VA FAN SPEED FUNCTION SPL(dB(A)) High Cooling 49 High Cooling 46 High Heating 50 High Heating 48 90 8000 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR 250 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 LINE 90 90 20 FAN SPEED FUNCTION SPL(dB(A)) LINE 80 70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 NC-70 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 63 BAND CENTER FREQUENCIES, Hz 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 66 4000 8000 MXZ-4A71VA FAN SPEED FUNCTION SPL(dB(A)) LINE MXZ-4A80VA Cooling 48 High Cooling 46 High Heating 50 High Heating 48 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 FAN SPEED FUNCTION SPL(dB(A)) High 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 80 125 250 500 1000 2000 4000 NC-20 10 8000 63 BAND CENTER FREQUENCIES, Hz 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz FAN SPEED FUNCTION SPL(dB(A)) MXZ-5A100VA APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE High Cooling 51 High Heating 54 LINE OUTDOOR UNIT 1m 90 OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR MICROPHONE 80 70 NC-70 60 Test conditions Cooling :Dry-bulb temperature 35°C Wet-bulb temperature 24°C Heating :Dry-bulb temperature 7°C Wet-bulb temperature 6°C NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz 67 7 OUTLINES AND DIMENSIONS MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA Unit: mm REQUIRED SPACE 400 Drainage hole Basically open 100mm or more without any obstruction in front and on both sides of the unit. ore or m mm 100 42 100 44 mm or m 17.5 Air in 344.5 304 325 ore ore or m mm 200 350 mm ore 40 Open two sides of left, right, or rear side. Air out 2-10x21 Oval hole 22.3 23 285 13 10 251.1 280 51 51 51 550 handle 302.5 150 Liquid pipe : Gas pipe : Liquid pipe : Gas pipe : 170.4 500 800 69 68 6.35(flared)1/4 9.52(flared)3/8 6.35(flared)1/4 9.52(flared)3/8 or m B unit connection A unit connection MXZ-3A54VA - E1 , , E2 E3 , Unit: mm E4 REQUIRED SPACE Open as a rule More than 500 mm if the front and both sides are open More than 100 mm More than 200 mm if there are obstacles to both sides More than 100 mm 500 Air out Open as a rule More than 500 mm if the back, both sides and top are open More than 350 mm 396 17.7 17.7 16.8 360.6 38 Air in 4-10 x 21 Oval hole Drainage holes 3- 33 840 Indoor and outdoor connect wiring 39 x 27 hole 30 30 330 27.1 13 Gas pipe 9.52(flared)3/8(A,B,C unit) 710 66.3 440 B unit connection 121 A unit connection 25 84 45 225 C unit connection 360 Air in 288 31 233.1 31.3 63.2 23.1 Liquid pipe 6.35(flared)1/4 69 , E6 169 500 233.1 31.3 171 288 Air in 20.3 16.8 63.2 Unit: mm E7 13.3 Air in 17.7 3- 33 Drain hole 396 , 360.6 (Bolt Pitch) E5 17.7 MXZ-3A54VA - Air out 4-10 x 21 Oval hole (Base bolt M10) 840 30 200 30 330 13 240 27.1 Indoor and outdoor connect wiring 39 x 27 hole 710 66.3 Gas pipe 9.52(flared)3/8 440 225 45 360 C unit connection B unit connection 84 A unit connection 299 Liquid pipe 23.1 6.35(flared)1/4 More than 100 More than 200 More than 100 2.Service space Note : Leave front and overhead clearance fully. More than 350 Note : Leave rear, overhead and both sides clearance fully. More than 100 More than 350 More than 500 More than 100 More than 350 Service space 70 More than 500 Note : Leave front and both sides clearance fully. More than 500 1.Installation space MXZ-4A71VA - E1 , E2 , E3 , Unit: mm E4 REQUIRED SPACE Open as a rule More than 500 mm if the front and both sides are open More than 100 mm More than 200 mm if there are obstacles to both sides More than 100 mm 500 Air out More than 350 mm 396 17.7 17.7 16.8 360.6 38 Air in 4-10 x 21 Oval hole Drainage holes 3- 33 840 Indoor and outdoor connect wiring 39 x 27 hole 30 30 330 13 Gas pipe 27.1 C unit connection B unit connection A unit connection 25 84 121 9.52(flared)3/8(B,C,D unit) 12.7(flared)1/2(A unit) D unit connection 440 315 45 710 66.3 360 Air in 288 31 233.1 31.3 63.2 Open as a rule More than 500 mm if the back, both sides and top are open 23.1 Liquid pipe 6.35(flared)1/4 71 E6 , 500 31.3 171 288 Air in 20.3 16.8 233.1 17.7 169 63.2 Unit: mm E7 13.3 Air in 17.7 3- 33 Drain hole 396 , E5 360.6 (Bolt Pitch) MXZ-4A71VA - Air out 4-10 x 21 Oval hole (Base bolt M10) 840 30 200 30 330 13 240 27.1 66.3 Gas pipe 9.52(flared)3/8(B,C,D unit) 12.7(flared)1/2(A unit) D unit connection 710 Indoor and outdoor connect wiring 39 x 27 hole 440 45 360 315 C unit connection B unit connection 84 A unit connection 299 23.1 Liquid pipe 6.35(flared)1/4 Note : Leave front and both sides clearance fully. More than 500 1.Installation space More than 100 Note : Leave front and overhead clearance fully. More than 350 Note : Leave rear, overhead and both sides clearance fully. More than 100 More than 350 More than 500 More than 100 More than 350 Service space 72 More than 500 More than 100 More than 200 2.Service space 200 500 250 270 Unit: mm (200) Air in 35 35 E1 2-U-shape notched holes (Base bolt M10) (27) (16) MXZ-4A80VA - 40 (16) 74 355 387 Air in Air out Drainage holes 3- 33 2-12 x 36 Oval hole (Base bolt M10) Gas pipe 9.52(flared)3/8(B,C,D unit) 12.7(flared)1/2(A unit) 900 320 30 900 88 23 480.8 531.3 D unit connection C unit connection B unit connection A unit connection 33 317 350 460 50 Indoor and outdoor connect wiring 26 x 45 hole 10 23 Liquid pipe 6.35(flared)1/4 More than 100 More than 200 More than 100 2.Service space Note : Leave front and overhead clearance fully. More than 350 Note : Leave rear, overhead and both sides clearance fully. More than 100 More than 350 More than 500 More than 100 More than 350 Service space 73 More than 500 Note : Leave front and both sides clearance fully. More than 500 1.Installation space MXZ-5A100VA 200 Unit: mm 200 2-U Shaped notched hole (Base bolt M10) Air out 355 (Bolt pitch) 387 11 Air in 16 270 250 35 74 35 500 27 E2 40 MXZ-4A80VA - 3- 33 Drain hole 16 24 Air in Gas pipe 9.52(flared) 3/8 (B,C,D,E (MXZ-5A100VA) unit) 12.7(flared) 1/2 (A unit) 2-12 x 36 Oval hole (Base bolt M10) 30 900 45 460 Indoor and outdoor connect wiring (35 x 53) hole 10 88 E unit connection (MXZ-5A100VA) D unit connection C unit connection B unit connection A unit connection 900 405 Handle 597 Handle 320 B 132 A 23 317 Liquid pipe 6.35(flared)1/4 More than 100 More than 200 More than 100 2.Service space Note : Leave front and overhead clearance fully. More than 350 Note : Leave rear, overhead and both sides clearance fully. More than 100 More than 350 More than 500 More than 100 More than 350 Service space 74 More than 500 Note : Leave front and both sides clearance fully. More than 500 1.Installation space 75 12-24V 230V~ 12-24V 230V~ S3 TB2 S2 S1 S3 TB3 S2 S1 N TB1 BLK GRN/YLW BLK BLU L65 BLU BLK RED BLU ORN BLK GRN SYMBOL NAME CT61,CT761,CT781 CURRENT TRANSFORMER C63A,C63B,C63C SMOOTHING CAPACITOR DB61,DB65 DIODE MODULE F61 FUSE (T20AL250V) F64,F801,F901 FUSE (T3.15AL250V) IC801 INTELLIGENT POWER DEVICE IPM,IC932 INTELLIGENT POWER MODULE L64,L65 REACTOR MC COMPRESSOR TO INDOOR UNIT No.A CONNECTING TO INDOOR UNIT No.B CONNECTING CIRCUIT BREAKER L PE POWER P.C. BOARD F61 NF RT68 SYMBOL MF NF NR64 RT61 RT62 RT64 RT65 NR64 F64 X64 R64B 4 DISPLAY P.C. BOARD LED1 LED2 SSR61 R64A CT61 SW1 CN936 CN934 CN912 3 1 2 TAB4 NAME OUTDOOR FAN MOTOR NOISE FILTER VARISTOR DEFROST THERMISTOR DISCHARGE TEMPERATURE THERMISTOR FIN TEMPERATURE THERMISTOR AMBIENT TEMPERATURE THERMISTOR OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR CN938 1 2 CN602 3 1 CN601 2 3 INTERFACE 4 5 P.C. BOARD LDE TAB2 TAB1 BLU BLK LD69 LD70 CN935 CN937 CN933 R831 RT61 RT62 RT68 CN661 1 2 3 4 5 6 DB65 DB61 C63B C63A C63C + IC801 T801 F801 RT65 CN663 1 2 LEV A CN791 R62 F901 R61 6 W V U IPM W V U IC932 N P N P LEV B CN792 CT781 CT761 6 1 2 3 CN932 C N 9 3 1 LDU LDV LDW 5 BLK BLK WHT 1 WHT 2 RED 3 RED CN61 W MF MC V U NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector RT64 CN662 1 2 INVERTER P.C. BOARD TR821 + + NAME CURRENT-DETECTING RESISTOR RESISTOR TERMINAL BLOCK SWITCHING POWER TRANSISTOR SWITCHING TRANS RELAY R.V. COIL EXPANSION VALVE SOLENOID COIL RELAY 7 6 7 21S4 L64 SYMBOL R61,R62,R831 R64A,R64B TB1,TB2,TB3 TR821 T801 X64 21S4 LEV A,LEV B SSR61 BLK MXZ-2A30VA MXZ-2A40VA BLU POWER SUPPLY ~/N 230V 50Hz BLK 8 WIRING DIAGRAM MXZ-2A52VA SYMBOL CB1~3 CT1, 2 CT61 F64 F801 F911 HC930 IPM L LEV A~C LEV E S3 S2 S1 TB2 S3 S2 S1 TB3 BLK BLU NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T3.15AL250V) FUSE (T1AL250V) INTELLIGENT POWER MODULE INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE EXPANSION VALVE 230V~ TO INDOOR UNIT No.A 12-24V CONNECTING 230V~ TO INDOOR UNIT No.B 12-24V CONNECTING 230V~ S3 S2 S1 TB4 L N CIRCUIT BREAKER TO INDOOR UNIT No.C 12-24V CONNECTING POWER SUPPLY ~/N 230V~ 50Hz BLK BLU BLK BLU LEV A LEV B 1 2 3 4 5 CN901 R64B 1 2 3 4 5 CN781 2 WHT 1 TAB4 BLK BLK BLK 4 BLK 3 3 LEV C S YLW 1 2 CN4 RT68 RT61 RT62 CN661 1 2 3 4 5 6 7 8 RT65 F801 LD2 CN795 1 2 3 4 5 6 T801 RS2 RS1 CB1 LEV E RS4 RS3 CB3 R937B R937A 1 2 3 CN801 LD1 CB2 POWER BOARD CT2 HC930 GRN LD9 IPM CT1 W V U CN932 CN931 MC YLW BLU ORN PNK GRY BLK WHT RED BLK BLK RED WHT BLK U V W MF NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector CN663 1 2 1 2 CN701 RT6A RT6C RT6B CN662 1 2 3 4 5 6 7 8 R RED 1 2 3 4 5 6 7 CN702 ELECTRONIC CONTROL P.C. BOARD 21S4 (BLU) CN793 1 2 3 4 5 6 GRN GRN SSR61 NR64 R64A 1 2 CN912 (RED) CN792 1 2 3 4 5 6 LDE2 LDE1 F911 CT61 (WHT) CN791 1 2 3 4 5 6 CN61 N/F N NAME SYMBOL NAME SYMBOL MC COMPRESSOR RT64 FIN TEMPERATURE THERMISTOR OUTDOOR FAN MOTOR MF RT65 AMBIENT TEMPERATURE THERMISTOR NR64 VARISTOR RT68 OUTDOOR HEAT EXCHANGER N/F NOISE FILTER TEMPERATURE THERMISTOR PFC POWER FACTOR CONTROLLER SSR61 SOLENOID COIL RELAY R64A,B RESISTOR T801 TRANSFORMER R937A, B RESISTOR TB1~4 TERMINAL BLOCK RS1~4 RESISTOR X64 RELAY RT6A~C GAS PIPE TEMPERATURE THERMISTOR 21S4 R.V. COIL RT61 DEFROST THERMISTOR RT62 DISCHARGE TEMPERATURE THERMISTOR BLK BLU RED ORN YLW TAB2 TAB1 F64 X64 L PFC WHT GRN/YLW BLK BLU PE 1 2 3 1 2 3 BLU NOISE FILTER P.C. BOARD BLK GROUND RED RT64 TB1 CN603 CN602 CN601 BRN BLU ORN YLW WHT BLK BLK BLK GRY GRY GRY GRY GRY GRY 3 2 1 BRN BLU ORN YLW WHT RED BLK BLK BLK CN5 GRY GRY BLK BLK 1 2 3 4 5 BLU BRN BLU ORN YLW WHT RED BLK 2 1 7 6 5 4 3 2 1 CN2 BLK BLK GRY GRY 76 GRY GRY 1 2 CN902 RED 1 2 CN903 RED , BRN BLU ORN YLW WHT E2 CN3 1 2 , 3 2 1 E1 5 4 3 2 1 MXZ-3A54VA E3 SYMBOL CB1~3 CT1, 2 CT61 F64 F801 F911 HC930 IPM L LEV A~C LEV E NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T3.15AL250V) FUSE (T1AL250V) INTELLIGENT POWER MODULE INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE EXPANSION VALVE NAME SYMBOL NAME SYMBOL MC COMPRESSOR RT65 AMBIENT TEMPERATURE THERMISTOR OUTDOOR FAN MOTOR MF RT68 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR NR64 VARISTOR N/F NOISE FILTER SSR61 SOLENOID COIL RELAY PFC POWER FACTOR CONTROLLER T801 TRANSFORMER R64A,B RESISTOR TB1~4 TERMINAL BLOCK R937A, B RESISTOR X64 RELAY 21S4 R.V. COIL RS1~4 RESISTOR RT61 DEFROST THERMISTOR RT62 DISCHARGE TEMPERATURE THERMISTOR RT64 FIN TEMPERATURE THERMISTOR NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector MXZ-3A54VA E4 77 78 230V~ 12-24V TB2 230V~ 12-24V TB3 230V~ 12-24V TB4 CIRCUIT BREAKER S3 S2 S1 S3 S2 S1 S3 S2 S1 L N BLU BLK BLK RED ORN YLW BLK BLU RED BLK BLU ORN BLK BLU YLW BLU BLU BLK CN61 TAB2 TAB1 1 CN601 5 3 CN602 1 3 CN603 1 1 3 N/F F65 SYMBOL CB1~3 CT1,2 CT61 F64 F65 F801 NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE(T2AL250V) FUSE(T6.3AL250V) FUSE(T3.15AL250V) SYMBOL HC930 IPM L LEV A~C LEV E MC LDE1 N/F SSR61 2 21S4 PTC64 PTC65 NR64 CN912 1 U F64 1 CN901 1 CN781 5 5 CN903 1 2 CN902 1 2 TAB4 3 1 WHT BLK NAME FAN MOTOR VARISTOR NOISE FILTER POWER FACTOR CONTROLLER CIRCUIT PROTECTION RESISTOR LEV B LEV A SYMBOL MF NR64 N/F PFC PTC64,65 R937A,B M 6 (RED) CN792 M 6 (WHT) CN791 ELECTRONIC CONTROL P.C.BOARD NAME INTELLIGENT POWER MODULE INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE EXPANSION VALVE COMPRESSOR NOTES: 1. About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2. Use copper conductors only (For field wiring). 3. Symbols below indicate. :Terminal block :Connector TO INDOOR UNIT No.A CONNECTING TO INDOOR UNIT No.B CONNECTING TO INDOOR UNIT No.C CONNECTING POWER SUPPLY ~/N 230V 50Hz CT61 BLK BLK BLK GRN/YLW BLK PE BLK X64 CN702 7 BLK BLK BLK BLK BLK BLK BLK YLW RED LEV C M 6 7 CN2 1 1 2 LED2 CN5 S R 2 RT61 1 LED1 CN701 1 2 1 CN4 RT62 LD2 F801 RT68 CN661 T801 RS2 RS1 1 8 CB1 CB2 RT65 1 CB3 + SYMBOL SSR61 T801 TB1~4 X64 21S4 2 R937B R937A RS4 RS3 + CN663 3 CN801 LD1 + POWER BOARD NAME RESISTOR DEFROST THERMISTOR DISCHARGE TEMP.THERMISTOR FIN TEMP.THERMISTOR AMBIENT TEMP.THERMISTOR OUTDOOR HEAT EXCHANGER TEMP.THERMISTOR LED3 (BLU) CN793 2 4 SYMBOL RS1~4 RT61 RT62 RT64 RT65 RT68 1 3 L PFC GRN NOISE FILTER P.C.BOARD WHT TB1 BLK LEV E M 6 CN3 W 1 3 5 YLW BLU ORN PNK GRY BLK WHT RED RED WHT V V U MS 3~ MF 8 RT64 W MS 3~ MC BLK U CN932 1 CN931 CN795 HC930 2 1 CT2 CT1 NAME SOLENOID COIL RELAY TRANSFORMER TERMINAL BLOCK RELAY REVERSING VALVE SOLENOID COIL LD9 IPM , BLK E5 RED MXZ-3A54VA E6 MXZ-3A54VA - E7 79 230V~ S3 S2 S1 TB2 S3 S2 S1 TB3 S3 S2 S1 TB4 S3 S2 S1 TB5 BLK BLU BLK BLU RED ORN YLW BRN NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T3.15AL250V) FUSE (T1AL250V) INTELLIGENT POWER MODULE INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE EXPANSION VALVE 230V~ TO INDOOR UNIT No.A 12-24V CONNECTING 230V~ TO INDOOR UNIT No.B 12-24V CONNECTING 230V~ TO INDOOR UNIT No.C 12-24V CONNECTING SYMBOL CB1~3 CT1, 2 CT61 F64 F801 F911 HC930 IPM L LEV A~D LEV E PE L N CIRCUIT BREAKER TO INDOOR UNIT No.D 12-24V CONNECTING POWER SUPPLY ~/N 230V~ 50Hz TAB2 TAB1 CN901 1 2 3 4 5 1 2 3 4 5 CN781 1 2 3 4 5 6 7 CN702 S CN4 1 2 SYMBOL MC MF NR64 N/F PFC R64A,B R937A, B RS1~4 RT6A~D RT61 RT62 LEV A LEV C LEV D RT68 RT61 RT62 RT6A RT6C RT6B RT6D CN663 1 2 RT65 RS2 RS1 LD2 CB1 F801 R937B R937A CT2 HC930 GRN LD9 IPM CT1 W V U CN932 CN931 MC YLW BLU ORN PNK GRY BLK WHT RED BLK BLK RED WHT BLK U V W MF NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector LEV E RS4 RS3 CB3 1 2 3 CN801 LD1 CB2 POWER BOARD CN795 1 2 3 4 5 6 T801 PFC NAME SYMBOL NAME RT64 FIN TEMPERATURE THERMISTOR COMPRESSOR OUTDOOR FAN MOTOR RT65 AMBIENT TEMPERATURE THERMISTOR VARISTOR RT68 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR NOISE FILTER SSR61 SOLENOID COIL RELAY POWER FACTOR CONTROLLER RESISTOR T801 TRANSFORMER RESISTOR TB1~5 TERMINAL BLOCK RESISTOR X64 RELAY GAS PIPE TEMPERATURE THERMISTOR 21S4 R.V. COIL DEFROST THERMISTOR DISCHARGE TEMPERATURE THERMISTOR LEV B CN661 1 2 3 4 5 6 7 8 CN662 1 2 3 4 5 6 7 8 1 2 CN701 (GRN) CN794 1 2 3 4 5 6 ELECTRONIC CONTROL P.C. BOARD 21S4 CN912 YLW (BLU) CN793 1 2 3 4 5 6 GRN GRN 1 2 SSR61 BLK BLK BLK 2 WHT 1 TAB4 R (RED) CN792 1 2 3 4 5 6 LDE2 LDE1 F911 CT61 NR64 R64A R64B RED (WHT) CN791 1 2 3 4 5 6 CN61 N/F F64 4 BLK 3 3 L RED BRN BLU ORN YLW WHT WHT GRN/YLW BLU RED BRN BLU ORN YLW WHT BLK BLU 3 2 1 RED BRN BLU ORN YLW WHT GROUND CN604 N RED BRN BLU ORN YLW WHT RT64 TB1 BLU BLK 1 2 3 CN603 1 2 3 1 2 3 BLU X64 BLK NOISE FILTER P.C. BOARD BLK BLK BLK GRY GRY BLK BLK BLK BLU BLK BLU BLK BLK BLK CN5 GRY GRY GRY GRY GRY GRY GRY GRY CN601 CN602 1 2 3 4 5 BLK 2 1 7 6 5 4 3 2 1 CN2 BLK BLK GRY GRY 80 GRY GRY 1 2 CN902 RED 1 2 CN903 RED , BRN BLU ORN YLW WHT E2 CN3 1 2 , 3 2 1 E1 5 4 3 2 1 MXZ-4A71VA E3 SYMBOL CB1~3 CT1, 2 CT61 F64 F801 F911 HC930 IPM L LEV A~D LEV E NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T3.15AL250V) FUSE (T1AL250V) INTELLIGENT POWER MODULE INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE EXPANSION VALVE SYMBOL MC MF NR64 N/F PFC R64A,B R937A, B RS1~4 RT61 RT62 RT64 NAME COMPRESSOR OUTDOOR FAN MOTOR VARISTOR NOISE FILTER POWER FACTOR CONTROLLER RESISTOR RESISTOR RESISTOR DEFROST THERMISTOR DISCHARGE TEMPERATURE THERMISTOR FIN TEMPERATURE THERMISTOR SYMBOL NAME RT65 AMBIENT TEMPERATURE THERMISTOR RT68 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR SSR61 SOLENOID COIL RELAY T801 TRANSFORMER TB1~5 TERMINAL BLOCK X64 RELAY 21S4 R.V. COIL NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector MXZ-4A71VA E4 81 82 230V~ 12-24V TB2 230V~ 12-24V TB3 230V~ 12-24V TB4 230V~ 12-24V TB5 CIRCUIT BREAKER S3 S2 S1 S3 S2 S1 S3 S2 S1 S3 S2 S1 L N BLU BLK BLK RED ORN YLW BLU RED BLK BLU ORN BLK BLU BRN BLK BLK YLW BLU BLU BRN BLU BLK CN61 TAB2 1 CN601 3 CN604 1 3 CN603 1 3 CN602 1 5 1 3 N/F F65 SYMBOL CB1~3 CT1,2 CT61 F64 F65 F801 NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE(T2AL250V) FUSE(T6.3AL250V) FUSE(T3.15AL250V) SYMBOL HC930 IPM L LEV A~D LEV E MC LDE1 N/F SSR61 2 CT61 21S4 PTC64 PTC65 NR64 CN912 1 U F64 1 CN901 1 CN781 5 5 CN903 1 2 CN902 1 2 TAB4 3 1 WHT BLK LEV C M 6 (BLU) CN793 NAME FAN MOTOR VARISTOR NOISE FILTER POWER FACTOR CONTROLLER CIRCUIT PROTECTION RESISTOR LEV B LEV A SYMBOL MF NR64 N/F PFC PTC64,65 R937A,B M 6 (RED) CN792 M 6 (WHT) CN791 ELECTRONIC CONTROL P.C.BOARD NAME INTELLIGENT POWER MODULE INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE EXPANSION VALVE COMPRESSOR NOTES: 1. About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2. Use copper conductors only (For field wiring). 3. Symbols below indicate. : Terminal block : Connector TO INDOOR UNIT No.A CONNECTING TO INDOOR UNIT No.B CONNECTING TO INDOOR UNIT No.C CONNECTING TO INDOOR UNIT No.D CONNECTING POWER SUPPLY ~/N 230V 50Hz TAB1 BLK BLK BLK GRN/YLW BLK PE BLK X64 CN702 2 4 SYMBOL RS1~4 RT61 RT62 RT64 RT65 RT68 1 3 L 7 CN2 1 1 2 LED2 CN5 S R 2 RT61 1 LED1 CN701 1 2 1 CN4 RT62 LD2 F801 RT68 CN661 T801 RS2 RS1 1 8 CB1 CB2 RT65 1 CB3 + SYMBOL SSR61 T801 TB1~5 X64 21S4 2 R937B R937A RS4 RS3 + CN663 3 CN801 LD1 + POWER BOARD NAME RESISTOR DEFROST THERMISTOR DISCHARGE TEMP.THERMISTOR FIN TEMP.THERMISTOR AMBIENT TEMP.THERMISTOR OUTDOOR HEAT EXCHANGER TEMP.THERMISTOR LEV D M 6 (GRN) CN794 LED3 7 BLK BLK BLK BLK BLK BLK BLK YLW RED PFC GRN NOISE FILTER P.C.BOARD WHT TB1 BLK LEV E M 6 CN3 W 1 3 5 YLW BLU ORN PNK GRY BLK WHT RED RED WHT V V U MS 3~ MF 8 RT64 W MS 3~ MC BLK U CN932 1 CN931 CN795 HC930 2 1 CT2 CT1 NAME SOLENOID COIL RELAY TRANSFORMER TERMINAL BLOCK RELAY REVERSING VALVE SOLENOID COIL LD9 IPM , BLK E5 RED MXZ-4A71VA E6 MXZ-4A71VA - E7 83 SYMBOL CB1~3 CT1, 2 CT61 F64 F801 F911 HC930 HPS IPM L LEV A~D NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T3.15AL250V) FUSE (T1AL250V) INTELLIGENT POWER MODULE HIGH PRESSURE SWITCH INTELLIGENT POWER MODULE REACTOR EXPANSION VALVE SYMBOL LEV E MC MF NR64 N/F PFC R64A,B R937A, B RS1~4 RT6A~D RT61 NAME SYMBOL NAME RT62 DISCHARGE TEMPERATURE THERMISTOR EXPANSION VALVE RT64 FIN TEMPERATURE THERMISTOR COMPRESSOR OUTDOOR FAN MOTOR RT65 AMBIENT TEMPERATURE THERMISTOR VARISTOR RT68 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR NOISE FILTER SSR61 SOLENOID COIL RELAY POWER FACTOR CONTROLLER RESISTOR T801 TRANSFORMER RESISTOR TB1~5 TERMINAL BLOCK RESISTOR X64 RELAY GAS PIPE TEMPERATURE THERMISTOR 21S4 R.V. COIL DEFROST THERMISTOR NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector MXZ-4A80VA E1 84 SYMBOL CB1~3 CT1, 2 CT61 F64 F65 F801 F931 HC930 HPS IPM L NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T6.3AL250V) FUSE (T3.15AL250V) FUSE (T3.15AL250V) INTELLIGENT POWER MODULE HIGH PRESSURE SWITCH INTELLIGENT POWER MODULE REACTOR SYMBOL LEV A~D LEV F MC MF NR64 N/F PFC R64A,B R930A, B RS1~4 RT61 NAME EXPANSION VALVE EXPANSION VALVE COMPRESSOR OUTDOOR FAN MOTOR VARISTOR NOISE FILTER POWER FACTOR CONTROLLER RESISTOR RESISTOR RESISTOR DEFROST THERMISTOR SYMBOL NAME RT62 DISCHARGE TEMPERATURE THERMISTOR RT64 FIN TEMPERATURE THERMISTOR RT65 AMBIENT TEMPERATURE THERMISTOR RT68 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR SSR61 SOLENOID COIL RELAY T801 TRANSFORMER TB1~5 TERMINAL BLOCK X64 RELAY 21S4 R.V. COIL NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector MXZ-4A80VA E2 85 SYMBOL CB1~3 CT1, 2 CT61 F64 F65 F801 F931 HC930 HPS IPM L NAME SMOOTHING CAPACITOR CURRENT TRANSFORMER CURRENT TRANSFORMER FUSE (T2AL250V) FUSE (T6.3AL250V) FUSE (T3.15AL250V) FUSE (T3.15AL250V) INTELLIGENT POWER MODULE HIGH PRESSURE SWITCH INTELLIGENT POWER MODULE REACTOR SYMBOL LEV A~E LEV F MC MF NR64 N/F PFC R64A,B R930A, B RS1~4 RT61 NAME EXPANSION VALVE EXPANSION VALVE COMPRESSOR OUTDOOR FAN MOTOR VARISTOR NOISE FILTER POWER FACTOR CONTROLLER RESISTOR RESISTOR RESISTOR DEFROST THERMISTOR SYMBOL NAME RT62 DISCHARGE TEMPERATURE THERMISTOR RT64 FIN TEMPERATURE THERMISTOR RT65 AMBIENT TEMPERATURE THERMISTOR RT68 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR SSR61 SOLENOID COIL RELAY T801 TRANSFORMER TB1~6 TERMINAL BLOCK X64 RELAY 21S4 R.V. COIL NOTES: 1.About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing. 2.Use copper conductors only (for field wiring). 3.Symbols below indicate. :Terminal block :Connector MXZ-5A100VA 86 REFRIGERANT SYSTEM DIAGRAM 9 MXZ-2A30VA UNIT: mm Compressor R.V. coil OFF ON Indoor unit B Refrigerant flow in cooling Refrigerant flow in heating Muffler 4-way valve Stop valve (with service port) Outdoor heat exchanger temperature thermistor RT68 Stop valve (with service port) FAN-OUT HEX-OUT Indoor unit A Discharge temperature thermistor RT62 Capillary tube Indoor unit A Stop valve (with strainer #100) Defrost thermistor RT61 LEV A Ambient temperature thermistor RT65 Strainer #100 Capillary tube Indoor unit B Stop valve (with strainer #100) LEV B MAX REFRIGERANT PIPING LENGTH Indoor units Piping length each indoor unit (a, b) 15m Total piping length (a+b) 20m Bending point for each unit 15 Total bending point 20 a Outdoor unit 10m It does not matter which unit is higher. 10m ADDITIONAL REFRIGERANT CHARGE Outdoor unit Refrigerant piping length (one way, 2 unit total) precharged 20m (g) 10m b 1,150 0 Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. class 22/25 Indoor unit Pipe diameter Liquid 6.35(1/4) Gas 9.52(3/8) Extension pipe diameter Liquid Gas 6.35(1/4) 9.52(3/8) UNIT: mm (inch) Outdoor unit union diameter For Liquid 6.35(1/4) Indoor unit A Gas 9.52(3/8) Liquid 6.35(1/4) Indoor unit B Gas 9.52(3/8) 87 MXZ-2A40VA - E1 MXZ-2A52VA UNIT: mm Compressor R.V. coil OFF ON Indoor unit B Muffler 4-way valve Stop valve (with service port) Outdoor heat exchanger temperature thermistor RT68 Stop valve (with service port) FAN-OUT HEX-OUT Indoor unit A Discharge temperature thermistor RT62 Refrigerant flow in cooling Refrigerant flow in heating Ambient temperature thermistor RT65 Defrost thermistor RT61 Capillary tube Indoor unit A Capillary tube Stop valve (with strainer #100) LEV A Strainer #100 Distributor Capillary tube Indoor unit B Stop valve (with strainer #100) LEV B Indoor units MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b) 20m Total piping length (a+b) 30m Bending point for each unit 20 Total bending point 30 a Outdoor unit 15m It does not matter which unit is higher. 15m ADDITIONAL REFRIGERANT CHARGE Outdoor unit Refrigerant piping length (one way, 2 unit total) precharged 30m 20m (g) 10m b 1,300 200 0 Calculation : Xg = 20 g/m x (Refrigerant piping length(m) - 20) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. UNIT: mm (inch) class 22/25/35 Indoor unit Pipe diameter Liquid 6.35(1/4) Gas 9.52(3/8) Outdoor unit union diameter For Liquid 6.35(1/4) Indoor unit A Gas 9.52(3/8) Liquid 6.35(1/4) Indoor unit B Gas 9.52(3/8) Extension pipe diameter Liquid Gas 6.35(1/4) 9.52(3/8) 88 MXZ-2A40VA - E2 UNIT: mm Compressor R.V. coil OFF ON Indoor unit B Refrigerant flow in cooling Refrigerant flow in heating Muffler 4-way valve Stop valve (with service port) Outdoor heat exchanger temperature thermistor RT68 Stop valve (with service port) FAN-OUT HEX-OUT Indoor unit A Discharge temperature thermistor RT62 Ambient temperature thermistor RT65 Capillary tube Indoor unit A Stop valve (with strainer #100) Defrost thermistor RT61 LEV A Strainer #100 Capillary tube Indoor unit B Stop valve (with strainer #100) LEV B Indoor units MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b) 20m Total piping length (a+b) 30m Bending point for each unit 20 Total bending point 30 a Outdoor unit 15m 15m It does not matter which unit is higher. ADDITIONAL REFRIGERANT CHARGE Outdoor unit Refrigerant piping length (one way, 2 unit total) precharged 30m 20m (g) 1,150 10m b 200 0 Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 20) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. class 22/25/35 Indoor unit Pipe diameter Liquid 6.35(1/4) Gas 9.52(3/8) UNIT: mm (inch) Outdoor unit union diameter For Liquid 6.35(1/4) Indoor unit A Gas 9.52(3/8) Liquid 6.35(1/4) Indoor unit B Gas 9.52(3/8) Extension pipe diameter Liquid Gas 6.35(1/4) 9.52(3/8) 89 MXZ-3A54VA - E1 , E2 , E3 , UNIT: mm E4 Compressor R.V. coil OFF ON Discharge temperature thermistor RT62 Refrigerant flow in cooling Refrigerant flow in heating Oil separator Capillary tube Ball valve with service port Indoor unit C Indoor unit B Indoor unit A 4-way valve Muffler Outdoor heat exchanger temperature thermistor RT68 HEX-OUT FAN-OUT Ambient temperature thermistor RT65 Defrost thermistor RT61 Capillary tube Indoor unit A Indoor unit B Indoor unit C Capillary tube Strainer LEV A #100 Capillary tube Ball valve Strainer #100 Strainer LEV B #100 Capillary tube Strainer #100 Strainer #100 LEV E Distributor Power receiver LEV C MAX REFRIGERANT PIPING LENGTH Indoor units Piping length each indoor unit (a, b, c) 25m Total piping length (a+b+c) 50m Bending point for each unit 25 Total bending point 50 a b Outdoor unit 15m It does not matter which unit is higher. 15m ADDITIONAL REFRIGERANT CHARGE Outdoor unit Refrigerant piping length (one way, 3 unit total) precharged 50m 40m (g) 2,700 10m c 200 0 Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) class 22/25/35 50 Indoor unit Pipe diameter Liquid 6.35(1/4) Outdoor unit union diameter Extension pipe diameter For Liquid 6.35(1/4) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 12.7(1/2) Gas 12.7(1/2) Indoor unit A Indoor unit B Indoor unit C 90 Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) MXZ-3A54VA - E5 , E6 , UNIT: mm E7 Compressor R.V. coil OFF ON Discharge temperature thermistor RT62 Refrigerant flow in cooling Refrigerant flow in heating Oil separator Capillary tube Indoor unit C Stop valve with service port Indoor unit B Indoor unit A 4-way valve Muffler Outdoor heat exchanger temperature thermistor RT68 HEX-OUT FAN-OUT Ambient temperature thermistor RT65 Defrost thermistor RT61 Capillary tube Indoor unit A Indoor unit B Indoor unit C Capillary tube Strainer LEV A #100 Capillary tube Strainer Stop valve #100 Strainer LEV B #100 Capillary tube Strainer #100 Strainer #100 LEV E Distributor Power receiver LEV C MAX REFRIGERANT PIPING LENGTH Indoor units Piping length each indoor unit (a, b, c) 25m Total piping length (a+b+c) 50m Bending point for each unit 25 Total bending point 50 a b Outdoor unit 15m It does not matter which unit is higher. 15m ADDITIONAL REFRIGERANT CHARGE Outdoor unit Refrigerant piping length (one way, 3 unit total) precharged 50m 40m (g) 2,700 10m c 200 0 Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) class 22/25/35/42 50 Indoor unit Pipe diameter Liquid 6.35(1/4) Extension pipe diameter Outdoor unit union diameter For Liquid 6.35(1/4) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 12.7(1/2) Gas 12.7(1/2) Indoor unit A Indoor unit B Indoor unit C 91 Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) MXZ-4A71VA - E1 , E2 , E3 , UNIT: mm E4 Compressor R.V. coil OFF ON Discharge temperature thermistor RT62 Refrigerant flow in cooling Refrigerant flow in heating Oil separator Capillary tube Indoor unit D Ball valve with service port 4-way valve Indoor unit C Indoor unit B Indoor unit A Muffler Outdoor heat exchanger temperature thermistor RT68 HEX-OUT FAN-OUT Ambient temperature thermistor RT65 Capillary tube Indoor unit A Defrost thermistor RT61 Capillary tube Indoor unit B Indoor unit C Indoor unit D Strainer #100 LEV A Strainer #100 LEV B Strainer #100 LEV C Strainer #100 LEV D Ball valve Strainer #100 Strainer #100 LEV E Distributor Power receiver MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b, c, d) 25m Total piping length (a+b+c+d) 60m Bending point for each unit 25 Total bending point 60 Indoor units a b Outdoor unit 15m It does not matter which unit is higher. ADDITIONAL REFRIGERANT CHARGE Outdoor unit precharged (g) 2,700 15m c Refrigerant piping length (one way, 4 unit total) 40m 0 50m 60m 200 400 10m d Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) class 22/25/35 50 60 Indoor unit Pipe diameter Liquid 6.35(1/4) Outdoor unit union diameter Extension pipe diameter For Liquid 6.35(1/4) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 12.7(1/2) Gas 12.7(1/2) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 15.88(5/8) Gas 15.88(5/8) Indoor unit A Indoor unit B Indoor unit C Indoor unit D 92 Liquid 6.35(1/4) Gas 12.7(1/2) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) MXZ-4A71VA - E5 , E6 , UNIT: mm E7 Compressor R.V. coil OFF ON Discharge temperature thermistor RT62 Refrigerant flow in cooling Refrigerant flow in heating Oil separator Capillary tube Indoor unit D Stop valve with service port Indoor unit C Indoor unit B Indoor unit A 4-way valve Muffler Outdoor heat exchanger temperature thermistor RT68 HEX-OUT FAN-OUT Ambient temperature thermistor RT65 Capillary tube Indoor unit A Defrost thermistor RT61 Capillary tube Indoor unit B Indoor unit C Indoor unit D Strainer #100 LEV A Strainer #100 LEV B Strainer #100 LEV C Strainer #100 LEV D Strainer Stop valve #100 Strainer #100 LEV E Distributor Power receiver MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b, c, d) 25m Total piping length (a+b+c+d) 60m Bending point for each unit 25 Total bending point 60 Indoor units a b Outdoor unit 15m It does not matter which unit is higher. ADDITIONAL REFRIGERANT CHARGE 15m c Outdoor unit precharged (g) Refrigerant piping length (one way, 4 unit total) 50m 40m 2,700 200 0 60m 400 10m d Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) class 22/25/35/42 50 60 Indoor unit Pipe diameter Liquid 6.35(1/4) Outdoor unit union diameter Extension pipe diameter Liquid 6.35(1/4) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 12.7(1/2) Gas 12.7(1/2) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 15.88(5/8) Gas 15.88(5/8) For Indoor unit A Indoor unit B Indoor unit C Indoor unit D 93 Liquid 6.35(1/4) Gas 12.7(1/2) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) MXZ-4A80VA - UNIT: mm E1 Compressor R.V. coil OFF ON Refrigerant flow in cooling Refrigerant flow in heating Discharge temperature thermistor RT62 High-pressure switch Oil separator Capillary tube Ball valve with service port Indoor unit D Indoor unit C 4-way valve Muffler Indoor unit B Indoor unit A Outdoor heat exchanger Ambient temperature thermistor Outdoor heat RT65 exchanger temperature thermistor RT68 Capillary tube Indoor unit A Indoor unit B Indoor unit C Indoor unit D Defrost thermistor RT61 LEV A Strainer #100 Strainer #100 LEV B Strainer #100 LEV C Strainer #100 LEV D Capillary tube Ball valve Strainer #100 Strainer #100 LEV E Distributor Power receiver Distributor MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b, c, d) 25m Total piping length (a+b+c+d) 70m Bending point for each unit 25 Total bending point 70 Indoor units a b Outdoor unit 10m It does not matter which unit is higher. 10m ADDITIONAL REFRIGERANT CHARGE Outdoor unit precharged (g) c Refrigerant piping length (one way, 4 unit total) 40m 60m 50m 70m 10m d 3,500 0 400 200 600 Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) class 22/25/35 50 60 71 Indoor unit Pipe diameter Liquid 6.35(1/4) Outdoor unit union diameter Extension pipe diameter Liquid 6.35(1/4) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 12.7(1/2) Gas 12.7(1/2) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 15.88(5/8) Gas 15.88(5/8) Liquid 9.52(3/8) Liquid 9.52(3/8) Gas 15.88(5/8) Gas 15.88(5/8) For Indoor unit A Indoor unit B Indoor unit C Indoor unit D 94 Liquid 6.35(1/4) Gas 12.7(1/2) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) MXZ-4A80VA R.V. coil OFF ON UNIT: mm E2 High-pressure Compressor switch Discharge temperature thermistor RT62 Oil separator Refrigerant flow in cooling Refrigerant flow in heating Capillary tube Indoor unit D Stop valve (with service port) Indoor unit C Indoor unit B Indoor unit A 4-way valve Muffler Outdoor heat exchanger Ambient temperature thermistor Outdoor heat RT65 exchanger temperature thermistor RT68 Capillary tube Indoor unit A Indoor unit B Indoor unit C Indoor unit D Defrost thermistor RT61 LEV A Strainer #100 Strainer #100 LEV B Strainer #100 LEV C Strainer #100 LEV D Capillary tube Stop valve Strainer #100 Strainer #100 LEV F Distributor Power receiver Indoor units MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b, c, d) 25m Total piping length (a+b+c+d) 70m Bending point for each unit 25 Total bending point 70 a b Outdoor unit 15m It does not matter which unit is higher. 15m ADDITIONAL REFRIGERANT CHARGE c Outdoor unit precharged (g) 40m 50m 60m 70m 3,500 0 200 400 600 Refrigerant piping length (one way, 4 unit total) 10m d Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) class 22/25/35/42 50 60 71 Indoor unit Pipe diameter Liquid 6.35(1/4) Extension pipe diameter Liquid 6.35(1/4) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 12.7(1/2) Gas 12.7(1/2) Liquid 6.35(1/4) Liquid 6.35(1/4) Gas 15.88(5/8) Gas 15.88(5/8) Liquid 9.52(3/8) Liquid 9.52(3/8) Gas 15.88(5/8) Gas 15.88(5/8) 95 Outdoor unit union diameter For Indoor unit A Indoor unit B Indoor unit C Indoor unit D Liquid 6.35(1/4) Gas 12.7(1/2) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) Liquid 6.35(1/4) Gas 9.52(3/8) UNIT: mm MXZ-5A100VA High-pressure switch R.V. coil OFF ON Refrigerant flow in cooling Refrigerant flow in heating Compressor Discharge temperature thermistor RT62 Oil separator Capillary tube Indoor unit E Stop valve (with service port) Indoor unit D Indoor unit C Indoor unit B 4-way valve Muffler Indoor unit A Outdoor heat exchanger Ambient temperature thermistor Outdoor heat RT65 exchanger temperature thermistor RT68 Capillary tube Indoor unit A Indoor unit B Indoor unit C Indoor unit D Indoor unit E Defrost thermistor RT61 Strainer #100 LEV A Strainer #100 LEV B Strainer #100 LEV C Strainer #100 LEV D Strainer #100 LEV E Capillary tube Stop valve Strainer #100 Strainer #100 LEV F Distributor Power receiver MAX REFRIGERANT PIPING LENGTH Piping length each indoor unit (a, b, c, d,e) 25m Total piping length (a+b+c+d+e) 80m Bending point for each unit 25 Total bending point 80 Indoor units a b Outdoor unit 15m It does not matter which unit is higher. c ADDITIONAL REFRIGERANT CHARGE Outdoor unit precharged (g) 4,000 15m Refrigerant piping length (one way, 5 unit total) 40m 0 50m 200 60m 400 70m 600 80m 800 10m d e Calculation : Xg = 20 g/m x (Refrigerant piping length (m) - 40) Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the tables below. When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further information on Different-diameter pipe, see 17-1. UNIT: mm (inch) Outdoor unit union diameter Indoor unit Extension pipe diameter For class Pipe diameter Liquid 6.35(1/4) Liquid 6.35(1/4) Liquid 6.35(1/4) Indoor unit A 22/25/35/42 Gas 12.7(1/2) Gas 9.52(3/8) Gas 9.52(3/8) Liquid 6.35(1/4) Liquid 6.35(1/4) Liquid 6.35(1/4) Indoor unit B 50 Gas 9.52(3/8) Gas 12.7(1/2) Gas 12.7(1/2) Liquid 6.35(1/4) Liquid 6.35(1/4) Liquid 6.35(1/4) Indoor unit C 60 Gas 9.52(3/8) Gas 15.88(5/8) Gas 15.88(5/8) Liquid 6.35(1/4) Liquid 9.52(3/8) Liquid 9.52(3/8) Indoor unit D 71 Gas 9.52(3/8) Gas 15.88(5/8) Gas 15.88(5/8) Liquid 6.35(1/4) Indoor unit E Gas 9.52(3/8) 96 10 PERFORMANCE CURVES MXZ-2A30VA MXZ-3A54VA MXZ-5A100VA MXZ-2A40VA MXZ-4A71VA MXZ-2A52VA MXZ-4A80VA The standard specifications apply only to the operation of the air conditioner under normal conditions. Since operating conditions vary according to the areas where these units are installed, the following information has been provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve. (1) GUARANTEED VOLTAGE 198~264 V 50 Hz (2) AIR FLOW Air flow should be set at MAX. (3) MAIN READINGS } (1) Indoor intake air wet-bulb temperature : °CWB (2) Indoor outlet air wet-bulb temperature : °CWB Cooling (3) Outdoor intake air dry-bulb temperature : °CDB (4) Total input: W (5) Indoor intake air dry-bulb temperature : °CDB Heating (6) Outdoor intake air wet-bulb temperature : °CWB (7) Total input : W Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service. } How to measure the indoor air wet-bulb/dry-bulb temperature difference 1. 2. 3. 4. 5. 6. 7. Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air speed is high. Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake. Cover the thermometers to prevent direct rays of the sun. Check that the air filter is cleaned. Open windows and doors of room. Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature. 10 minutes later, measure temperature again and check that the temperature does not change. INDOOR UNIT OUTDOOR UNIT Wet and dry-bulb thermometers FRONT VIEW Wet-and dry-bulb thermometers BACK VIEW 97 9.3 10.6 7.8 8.5 9.7 7.1 7.8 8.8 6.4 7.0 7.9 5.8 6.3 7.1 5.1 5.6 6.3 25 class 25.4 24.0 25.9 23.4 22.2 23.9 21.5 20.3 21.9 19.5 18.5 19.9 17.6 16.6 17.9 12.9 13.9 11.7 11.1 12.0 r intak e air W et-bulb tempe rature Indo (°C) Outdoor intake air Dry-bulb temperature (°C) oor Ind 35 class 14.8 15.9 25 class 15.6 13.7 22 class Indoor air Dry-bulb temperature Indoo 35 class 8.5 22 class Indoor air Wet-bulb temperature 10-1. CAPACITY AND THE INPUT CURVES MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA ir ea ) (°C ture era p em lb t -bu Dry ) ture (°C tempera Outdoor intake air Dry-bulb temperature (°C) take or in Indo k inta et-bulb e air W or intak Outdoor intake air Wet-bulb temperature (°C) air ulb Dry-b ) re (°C eratu temp Outdoor intake air Wet-bulb temperature (°C) 9.5 13.1 13.7 7.8 8.5 9.7 8.7 11.9 12.4 7.1 7.8 8.8 8.0 10.8 11.3 6.4 7.0 7.9 7.2 9.7 10.1 5.8 6.3 7.1 6.5 8.7 9.0 5.1 5.6 6.3 5.7 7.7 8.0 22 class 25 class 42 class 60 class 50 class 9.3 10.6 35 class 8.5 25.4 24.0 25.9 27.0 31.4 31.9 23.4 22.2 23.9 24.9 29.0 29.4 21.5 20.3 21.9 22.8 26.6 27.0 19.5 18.5 19.9 20.7 24.1 24.5 17.6 16.6 17.9 18.7 21.7 22.1 11.7 11.1 12.0 12.4 14.5 14.7 60 class 17.2 50 class 19.6 14.5 16.9 42 class 16.6 19.3 12.9 13.9 35 class 14.8 15.9 25 class 15.6 13.7 22 class Indoor air Dry-bulb temperature Indoor air Wet-bulb temperature MXZ-3A54VA MXZ-4A71VA Indoo r intak e air W et-bulb tempe rature Ind (°C) Outdoor intake air Dry-bulb temperature (°C) oor Ind ir ea °C) k inta Outdoor intake air Wet-bulb temperature (°C) 98 ) ture (°C tempera Outdoor intake air Dry-bulb temperature (°C) b te l -bu Dry lb Wet-bu re ( atu er mp ke air oor inta take or in Indo air ulb Dry-b re eratu temp (°C) Outdoor intake air Wet-bulb temperature (°C) 9.5 13.1 13.7 17.0 8.5 9.7 8.7 11.9 12.4 15.4 7.1 7.8 8.8 8.0 10.8 11.3 13.9 6.4 7.0 7.9 7.2 9.7 10.1 12.5 5.8 6.3 7.1 6.5 8.7 9.0 11.1 24.0 25.9 27.0 31.4 31.9 35.1 23.4 22.2 23.9 24.9 29.0 29.4 32.4 21.5 20.3 21.9 22.8 26.6 27.0 29.7 19.5 18.5 19.9 20.7 24.1 24.5 27.0 12.9 13.9 14.5 16.9 17.2 18.9 11.7 11.1 12.0 12.4 14.5 14.7 16.2 r intak e air W et-bulb tempe rature (°C) Outdoor intake air Dry-bulb temperature (°C) ture et-bulb ke air W ulb ry-b p tem Outdoor intake air Dry-bulb temperature (°C) ) (°C oor ry-b e air D C) ture (° mpera ulb te k r inta Indoo ir D a ake ) ture (°C tempera inta Indoor era int Ind 71 class 13.7 60 class 19.6 21.6 50 class 22.1 24.3 16.6 19.3 42 class 18.7 21.7 14.8 15.9 35 class 16.6 17.9 25 class 17.6 15.6 Indoo 9.7 71 class 25 class 8.0 60 class 7.7 25.4 22 class Indoor air Dry-bulb temperature 5.7 35 class 5.6 6.3 5.1 50 class 9.3 10.6 7.8 42 class 8.5 22 class Indoor air Wet-bulb temperature MXZ-4A80VA Outdoor intake air Wet-bulb temperature (°C) Outdoor intake air Wet-bulb temperature (°C) 7.8 12.4 15.4 7.1 7.8 8.8 8.0 10.8 11.3 13.9 6.4 7.0 7.9 7.2 9.7 10.1 12.5 5.8 6.3 7.1 6.5 8.7 9.0 11.1 5.1 5.6 6.3 5.7 7.7 8.0 24.0 25.9 27.0 31.4 31.9 35.1 23.4 22.2 23.9 24.9 29.0 29.4 32.4 21.5 20.3 21.9 22.8 26.6 27.0 29.7 19.5 18.5 19.9 20.7 24.1 24.5 27.0 17.6 16.6 17.9 18.7 21.7 22.1 24.3 11.1 12.0 12.4 14.5 14.7 16.2 71 class 11.7 60 class 17.2 18.9 50 class 19.6 21.6 14.5 16.9 42 class 16.6 19.3 12.9 13.9 35 class 14.8 15.9 25 class 15.6 13.7 Indoo r intak e air W et-bulb 9.7 71 class 50 class 25.4 22 class Indoor air Dry-bulb temperature 60 class 13.7 17.0 8.7 11.9 42 class 9.5 13.1 8.5 9.7 35 class 9.3 10.6 25 class 8.5 22 class Indoor air Wet-bulb temperature MXZ-5A100VA tempe rature (°C) Outdoor intake air Dry-bulb temperature (°C) °C) re ( atu per ea tak r in oo Ind Outdoor intake air Wet-bulb temperature (°C) 99 ) ture (°C tempera Outdoor intake air Dry-bulb temperature (°C) ture pera em lb t -bu ry ir D Indoo bulb air Wetr intake or Indo e air intak tem -bulb (°C) Dry Outdoor intake air Wet-bulb temperature (°C) 10-2. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY (OUTDOOR UNIT: MXZ-2A30VA/2A40VA - E2 ) 1. 22-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 2. 25-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz (OUTDOOR UNIT: MXZ-2A40VA - 50 100 150 Hz 0 Frequency Frequency E2 50 100 150 Hz Frequency ) 3. 35-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz Frequency 0 50 100 Frequency 100 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-2A40VA - E1 , MXZ-2A52VA) 1. 22-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 2. 25-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 3. 35-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz Frequency 0 50 100 Frequency 101 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-3A54VA) 1. 22-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 2. 25-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 3. 35-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 150 Hz 0 Frequency 50 100 150 Hz 0 Frequency 50 100 150 Hz Frequency 4. 42-class unit in single operation <COOL>Capacity 1.5 <HEAT>Capacity <COOL>Total input 1.5 <HEAT>Total input 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 150 Hz 0 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 5. 50-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz 0 50 100 Frequency Frequency 102 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-4A71VA) 1. 22-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 2. 25-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 3. 35-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz Frequency 0 50 100 Frequency 103 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-4A71VA) 4. 42-class unit in single operation <COOL>Capacity 1.5 1.5 <COOL>Total input 1.5 <HEAT>Capacity 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 150 Hz 0 50 100 <HEAT>Total input 1.5 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 5. 50-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 6. 60-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz 0 50 100 Frequency Frequency 104 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-4A80VA) 1. 22-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 2. 25-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 3. 35-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz Frequency 0 50 100 Frequency 105 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-4A80VA) 4. 42-class unit in single operation <COOL>Capacity 1.5 <COOL>Total input 1.5 <HEAT>Capacity 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0.0 0 50 100 150 Hz 0.0 0 Frequency 50 100 150 Hz 0.0 0 50 100 <HEAT>Total input 1.5 150 Hz 0.0 0 Frequency Frequency 50 100 150 Hz Frequency 5. 50-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 6. 60-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 7. 71-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz 0 50 100 Frequency Frequency 106 150 Hz 0 50 100 Frequency 150 Hz (OUTDOOR UNIT: MXZ-5A100VA) 1. 22-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 2. 25-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 3. 35-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 150 Hz 0 Frequency 50 100 150 Hz 0 Frequency 50 100 150 Hz Frequency 4. 42-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 Frequency 150 Hz 107 0 50 100 Frequency 150 Hz 0 50 100 Frequency 150 Hz 5. 50-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 6. 60-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 150 Hz 0 Frequency 50 100 0 150 Hz 50 100 150 Hz 0 Frequency Frequency 50 100 150 Hz Frequency 7. 71-class unit in single operation <COOL>Capacity <HEAT>Capacity <COOL>Total input <HEAT>Total input 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0 50 100 Frequency 150 Hz 0 50 100 150 Hz 0 50 100 Frequency Frequency 108 150 Hz 0 50 100 Frequency 150 Hz 10-3. TEST RUN OPERATION (How to operate fixed-frequency operation) 1. Press EMERGENCY OPERATION switch to COOL or HEAT mode (COOL : Press once, HEAT : Press twice). 2. Test run operation starts and continues to operate for 30 minutes. 3. Compressor operates at rated frequency. 4. Indoor fan operates at High speed. 5. After 30 minutes, test run operation finishes and EMERGENCY OPERATION starts (Operation frequency of compressor varies). 6. To cancel test run operation (EMERGENCY OPERATION), press EMERGENCY OPERATION switch or any button on remote controller. 10-4. OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT (single operation) NOTE: The unit of pressure has been changed to MPa on the international system of units (SI unit system). The conversion factor is : 1 (MPa[Gauge]) = 10.2(kgf/cm2 [Gauge]) (1) COOL operation Dry-bulb temperature ( ) Relative humidity (%) 20 50 25 60 30 70 Both indoor and outdoor unit are under the same temperature/humidity condition. Operation : TEST RUN OPERATION (Refer to 10-3.) MXZ-2A30VA MXZ-2A40VA 22-class unit E2 25-class unit (MPa[Gauge]) 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 42Hz 20 50 25 60 30 70 3 42Hz 2 1 15 35 (%) Ambient temperature ( ) Ambient humidity (%) MXZ-2A40VA- 20 50 25 60 30 70 35 (%) E2 13 1.3 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 4 Outdoor unit current (A) Outdoor low pressure (MPa[Gauge]) 1.4 42Hz 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 3 42Hz 2 1 15 35 (%) 20 50 25 60 30 70 1.4 13 1.3 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 4 42Hz 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) Ambient temperature ( ) Ambient humidity (%) 35-class unit 14 14 Outdoor unit current (A) 13 1.3 Outdoor low pressure 4 1.4 Outdoor unit current (A) Outdoor low pressure (MPa[Gauge]) 14 35 (%) Ambient temperature ( ) Ambient humidity (%) 109 3 42Hz 2 1 15 35 (%) 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 35 (%) MXZ-2A40VA - MXZ-2A52VA E1 22-class unit 25-class unit (MPa[Gauge]) 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 30Hz 0.7 15 20 50 30Hz 2 1 15 35 30 70 25 60 3 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 1.4 13 1.3 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 35 30 70 25 60 14 4 Outdoor unit current (A) 13 1.3 4 Outdoor low pressure 1.4 Outdoor unit current (A) Outdoor low pressure (MPa[Gauge]) 14 30Hz 20 50 (%) 30 70 25 60 3 30Hz 2 1 15 35 Ambient temperature ( ) Ambient humidity (%) Ambient temperature ( ) Ambient humidity (%) 20 50 (%) 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 35-class unit 4 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 30Hz 20 30 70 25 3 30Hz 2 1 15 35 20 Ambient temperature ( ) Ambient humidity (%) 35 30 70 25 (%) (%) Ambient temperature ( ) Ambient humidity (%) MXZ-3A54VA MXZ-4A71VA 22-class unit 11 1.1 1.0 9 0.9 8 0.8 7 0.7 6 0.6 15 20 50 25 60 30 70 12 4 40Hz 3 2 1 15 35 Outdoor low pressure 40Hz 10 25-class unit 5 Outdoor unit current (A) Outdoor low pressure 12 (MPa[Gauge]) 1.2 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 25 60 30 70 10 1.0 9 0.9 8 0.8 7 0.7 15 20 50 1.0 9 0.9 8 0.8 7 0.7 6 0.6 15 20 50 30 70 25 60 4 40Hz 3 2 1 15 35 (%) Ambient temperature ( ) Ambient humidity (%) 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 4 40Hz 3 2 1 15 35 (%) Outdoor low pressure 1.1 10 (%) 5 Outdoor unit current (A) Outdoor low pressure 11 1.1 20 50 30 70 25 60 35 (%) Ambient temperature ( ) Ambient humidity (%) 42-class unit 40Hz 1.2 11 Ambient temperature ( ) Ambient humidity (%) (MPa[Gauge]) 1.3 12 5 40Hz 35 35-class unit 13 (MPa[Gauge]) 1.2 Outdoor unit current (A) 13 1.3 20 50 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 13 (MPa[Gauge]) 1.3 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 20 40Hz 25 Outdoor unit current (A) 1.4 Outdoor unit current (A) Outdoor low pressure (MPa[Gauge]) 14 30 110 4 40Hz 3 2 1 15 35 (%) Ambient temperature ( ) Ambient humidity (%) 5 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 35 (%) MXZ-3A54VA MXZ-4A71VA MXZ-4A71VA 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 20 50 25 60 30 70 4 40Hz 3 2 1 15 35 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 25 60 30 70 0.9 8 0.8 7 0.7 6 0.6 15 20 50 30 70 25 60 3 2 (%) 1.0 9 0.9 8 0.8 7 0.7 15 20 50 20 50 30 70 25 60 30 70 25 60 24Hz 3 2 (%) 20 50 30 70 25 60 35 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 20 50 1.1 1.0 9 0.9 8 0.8 7 0.7 6 0.6 15 35 30 70 25 60 (%) Ambient temperature ( ) Ambient humidity (%) 5 20 50 13 (MPa[Gauge]) 1.3 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 4 24Hz 3 2 1 15 35 30 70 25 60 20 50 (%) 35 30 70 25 60 (%) Ambient temperature ( ) Ambient humidity (%) 24Hz 20 50 (%) 25 60 30 70 35 Ambient temperature ( ) Ambient humidity (%) 5 4 24Hz 3 2 1 15 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 60-class unit 5 24Hz 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 4 24Hz 3 2 1 15 35 (%) Outdoor low pressure 1.2 11 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 4 1 15 35 Outdoor unit current (A) Outdoor low pressure 12 11 10 (%) 50-class unit (MPa[Gauge]) 1.3 2 1 15 35 30 70 25 60 3 (MPa[Gauge]) 1.2 35 5 Ambient temperature ( ) Ambient humidity (%) 13 20 50 24Hz Outdoor low pressure 10 0.8 15 40Hz 42-class unit Outdoor unit current (A) Outdoor low pressure 1.1 8 Ambient temperature ( ) Ambient humidity (%) 24Hz 1.2 0.9 12 24Hz 1 15 35 (MPa[Gauge]) 1.3 11 9 4 Ambient temperature ( ) Ambient humidity (%) 35-class unit 12 1.0 (%) 4 Ambient temperature ( ) Ambient humidity (%) 13 1.1 Outdoor low pressure 9 11 10 5 Outdoor unit current (A) Outdoor low pressure 10 1.0 1.2 25-class unit 24Hz 1.1 12 5 40Hz Ambient temperature ( ) Ambient humidity (%) (MPa[Gauge]) 1.2 11 1.3 35 MXZ-4A80VA 22-class unit 12 13 Outdoor unit current (A) 11 (MPa[Gauge]) 1.4 Outdoor unit current (A) 1.2 14 Outdoor unit current (A) 12 5 40Hz 20 50 25 60 30 70 35 (%) 14 (MPa[Gauge]) 1.4 13 1.3 12 1.2 5 Outdoor unit current (A) (MPa[Gauge]) 1.3 Outdoor low pressure 13 60-class unit Outdoor unit current (A) Outdoor low pressure 50-class unit 24Hz 11 1.1 10 1.0 9 0.9 8 0.8 15 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) Ambient temperature ( ) Ambient humidity (%) 111 4 24Hz 3 2 1 15 35 (%) 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 35 (%) MXZ-5A100VA 22-class unit 71-class unit (MPa[Gauge]) 1.4 1.3 11 1.1 10 1.0 9 0.9 8 0.8 15 20 50 30 70 25 60 24Hz 3 2 1 15 35 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 0.9 8 0.8 7 0.7 6 0.6 15 20 50 30 70 25 60 4 24Hz 3 2 1 15 35 20 50 (%) Ambient temperature ( ) Ambient humidity (%) 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 20 50 24Hz 25 60 30 70 4 24Hz 3 2 20 50 (%) 25 60 30 70 1.1 10 1.0 9 0.9 8 0.8 15 20 50 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 20 50 13 (MPa[Gauge]) 1.3 12 1.2 11 1.1 10 1.0 9 0.9 8 0.8 7 0.7 15 35 (%) 20 50 (%) 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 5 25 60 30 70 4 24Hz 3 2 1 15 35 20 50 (%) 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 20 50 5 24Hz 30 70 25 60 4 24Hz 3 2 1 15 35 (%) Ambient temperature ( ) Ambient humidity (%) 14 (MPa[Gauge]) 1.4 13 1.3 12 1.2 5 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 4 24Hz 3 2 1 15 35 (%) Outdoor low pressure 11 1 15 35 20 50 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 71-class unit Outdoor unit current (A) Outdoor low pressure 1.2 12 Ambient temperature ( ) Ambient humidity (%) 24Hz 12 2 Ambient temperature ( ) Ambient humidity (%) 5 1 15 35 (MPa[Gauge]) 1.4 1.3 30 70 25 60 (MPa[Gauge]) 1.3 (%) 60-class unit 13 20 50 3 50-class unit Ambient temperature ( ) Ambient humidity (%) 14 0.6 15 24Hz Outdoor low pressure 12 6 Ambient temperature ( ) Ambient humidity (%) Outdoor unit current (A) Outdoor low pressure 13 0.7 35 30 70 25 60 42-class unit (MPa[Gauge]) 1.3 0.8 7 13 Outdoor low pressure Outdoor unit current (A) Outdoor low pressure 9 8 24Hz Ambient temperature ( ) Ambient humidity (%) 5 1.1 1.0 0.9 4 35-class unit (MPa[Gauge]) 1.2 10 9 Ambient temperature ( ) Ambient humidity (%) 24Hz 11 1.0 (%) MXZ-5A100VA 25-class unit 12 10 35 30 70 25 60 1.1 Outdoor unit current (A) 1.2 11 Outdoor unit current (A) 12 4 20 50 25 60 30 70 35 (%) Ambient temperature ( ) Ambient humidity (%) 5 Outdoor unit current (A) 13 5 24Hz Outdoor low pressure 24Hz (MPa[Gauge]) 1.2 12 5 Outdoor unit current (A) Outdoor low pressure 14 Outdoor unit current (A) MXZ-4A80VA 24Hz 11 1.1 10 1.0 9 0.9 8 0.8 15 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 112 4 24Hz 3 2 1 15 35 (%) 20 50 25 60 30 70 Ambient temperature ( ) Ambient humidity (%) 35 (%) HEAT operation Condition : Indoor Outdoor Dry bulb temperature (°C) 20.0 2 7 15 20.0 Wet bulb temperature (°C) 14.5 1 6 12 14.5 Operation : TEST RUN OPERATION (Refer to 10-3.) MXZ-2A30VA MXZ-2A40VA22-class unit Outdoor unit current (A) 2 48Hz 3 2 1 1 10 15 20 MXZ-2A40VA- 10 15 20 25 5 Ambient temperature ( ) Outdoor unit current (A) 35Hz 3 2 1 35Hz 3 2 20 25 5 7 2 10 15 20 5 25 48Hz 5 4 3 2 6 48Hz 5 4 3 25 Ambient temperature ( ) 42-class unit 7 48Hz 5 4 3 10 15 20 25 5 10 15 20 25 MXZ-4A71VA 60-class unit 7 Outdoor unit current (A) 5 48Hz 4 3 6 5 48Hz 4 3 2 2 5 10 15 20 5 25 10 15 20 Ambient temperature ( ) Ambient temperature ( ) 113 48Hz 5 4 3 0 5 10 15 20 25 Ambient temperature ( ) Ambient temperature ( ) 6 6 2 2 5 7 Outdoor unit current (A) 25 6 Ambient temperature ( ) MXZ-3A54VA MXZ-4A71VA 50-class unit 20 7 2 20 15 35-class unit Outdoor unit current (A) 6 10 Ambient temperature ( ) 7 Outdoor unit current (A) Outdoor unit current (A) 35Hz 3 Ambient temperature ( ) MXZ-3A54VA MXZ-4A71VA 22-class unit 25-class unit 15 25 1 1 10 20 4 Ambient temperature ( ) 5 15 35-class unit 25-class unit 4 15 10 Ambient temperature ( ) MXZ-2A52VA E1 4 10 2 1 5 25 22-class unit 5 48Hz 3 Outdoor unit current (A) 5 Ambient temperature ( ) Outdoor unit current (A) Outdoor unit current (A) 48Hz 4 Outdoor unit current (A) 4 3 E2 35-class unit 25-class unit 4 Outdoor unit current (A) MXZ-2A40VA- E2 25 7 32Hz 5 4 3 2 6 32Hz 5 4 3 2 5 10 15 20 25 20 6 5 32Hz 4 3 15 20 5 32Hz 4 3 10 15 20 4 3 2 50-class unit 5 4 3 10 15 20 4 3 5 10 15 20 Ambient temperature ( ) 25 15 20 25 25 42-class unit 7 32Hz 5 4 3 10 15 20 25 7 5 32Hz 4 3 6 5 32Hz 4 3 2 5 10 15 20 25 5 Ambient temperature ( ) 10 15 20 Ambient temperature ( ) 114 32Hz 5 4 3 0 5 10 15 20 25 Ambient temperature ( ) 71-class unit 6 6 2 5 Ambient temperature ( ) 2 2 10 6 25 Outdoor unit current (A) Outdoor unit current (A) 32Hz 20 3 2 5 7 5 15 32Hz 7 60-class unit 6 10 4 Ambient temperature ( ) 7 5 Ambient temperature ( ) 35-class unit 32Hz Ambient temperature ( ) 0 5 5 6 25 25 Ambient temperature ( ) 2 20 20 6 25 Outdoor unit current (A) Outdoor unit current (A) 5 15 2 5 7 32Hz 3 7 25-class unit 6 4 2 10 32Hz 5 71-class unit Ambient temperature ( ) 7 15 3 6 Ambient temperature ( ) 2 25 MXZ-5A100VA 22-class unit 10 4 5 6 Ambient temperature ( ) 5 5 25 Outdoor unit current (A) Outdoor unit current (A) Outdoor unit current (A) 15 7 2 Outdoor unit current (A) 10 60-class unit 7 10 32Hz Ambient temperature ( ) 50-class unit 5 6 2 5 Ambient temperature ( ) 7 Outdoor unit current (A) 6 42-class unit 7 Outdoor unit current (A) Outdoor unit current (A) Outdoor unit current (A) 7 Outdoor unit current (A) 35-class unit 25-class unit Outdoor unit current (A) MXZ-4A80VA 22-class unit 25 11 ACTUATOR CONTROL MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA Relation between main sensor and actuator Sensor Purpose Discharge temperature thermistor Protection Indoor coil thermistor Defrosting Protection Defrost thermistor Gas pipe temperature thermistor (MXZ-3A54VA- E1 , E2 , E3 MXZ-4A71VA- E1 , E2 , E3 MXZ-4A80VA- E1 ) Defrosting Fin temperature thermistor Protection Ambient temperature thermistor Outdoor heat exchanger temperature Capacity code Compressor Control Control Protection Control 115 Actuator Outdoor Reversing LEV fan motor valve 12 SERVICE FUNCTIONS MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA 12-1. LOCKING THE OPERATION MODE OF THE CONDITIONER (COOL, DRY, HEAT) Description of the function: With this function, you can lock the operation mode of the outdoor unit. Once the operation mode is locked to either COOL/DRY mode or HEAT mode, the air conditioner operates in that mode only. Initial setting is required to activate this function. Please explain about this function to your customers and ask them whether they want to use it. ON MXZ-2A30/2A40/2A52 [How to lock the operation mode] COOL/DRY Turn OFF the power supply for the air conditioner before making the setting. Set SW1 on the display P.C. board or the outdoor electronic control P.C. board as shown in the right figure. Turn ON the power supply for the air conditioner. MXZ-3A54/4A71VA MXZ-4A80VA- E1 HEAT SW1 SW1 ON ON MXZ-2A30/2A40/2A52/3A54/4A71VA MXZ-4A80VA- E1 COOL/DRY HEAT SW1 SW2 SW1 SW1 ON SW871 ON MXZ-4A80VA- E2 MXZ-5A100VA 12-2. LOWERING THE OPERATING NOISE OF THE OUTDOOR UNIT MXZ-4A80VA- E2 MXZ-5A100VA Description of the function: With this function, you can lower the operating noise of the outdoor unit when the operation load is small, for example, during nighttime in COOL mode. However, please note that the cooling and heating capacity can also be lowered if this function is activated. Initial setting is required to activate this function. Please explain about this function to your customers and ask them whether they want to use it. [How to lower the operating noise] Turn OFF the power supply for the air conditioner before making the setting. Set the 3rd Dip Switch of SW1 on the display P.C. board or the outdoor electronic control P.C. board to ON to enable this function. Turn ON the power supply for the air conditioner. 12-3. PRE-HEAT CONTROL <MXZ-2A, MXZ-3A54VA- E4 , MXZ-4A80VA- E2 , MXZ-5A100VA> E5 , E6 , E7 SW1 ON , MXZ-4A71VA- E4 , E5 , E6 , E7 , If moisture gets into the refrigerant cycle, or when refrigerant is liquefied and collected in the compressor, it may interfere the start-up of the compressor. To improve start-up condition, the compressor is energized even while it is not operating. This is to generate heat at the winding. The compressor uses about 50 W when pre-heat control is turned ON. Pre-heat control is ON at initial setting. [How to deactivate pre-heat control] Turn OFF the power supply for the air conditioner before making the setting. Set the 4th Dip Switch of SW2 on the outdoor electronic control P.C. board to ON to deactivate pre-heat control function (MXZ-4A80VA- E2 , MXZ-5A100VA). Set the 4th Dip Switch of SW1 on the outdoor electronic control P.C. board to ON to deactivate pre-heat control function (MXZ-3A54VA- E4 , E5 , E6 , E7 , MXZ-4A71VA- E4 , E5 , E6 , E7 ). Cut the JK wire of the inverter P.C. board to deactivate pre-heat control SW2 function (MXZ-2A). ON SW2 1 2 3 4 5 6 SW1 ON JK ON JK 1 2 3 4 5 6 MXZ-4A80VA- E2 MXZ-5A100VA 1 2 3 4 MXZ-3A54VA- E4 , E5 , E6 MXZ-4A71VA- E4 , E5 , E6 , E7 , E7 SW1 SW2 SW871 MXZ-2A Turn ON the power supply for the air conditioner. NOTE: Pre-heat control will be turned OFF when the breaker is turned OFF. 116 MXZ-4A80VA- E2 MXZ-5A100VA 12-4. AUTO LINE CORRECTING Outdoor unit has an auto line correcting function which automatically detects and corrects improper wiring or piping. <MXZ-2A> Improper wiring or piping can be automatically detected when one indoor unit is operated in COOL mode for 30 minutes. When improper wiring or piping is detected, wiring lines are corrected (A to B/ B to A) with the software. NOTE: This function may not work due to the condition or environment of the unit, such as the following: - gas leak, closed stop valve - unit failure such as defective LEV - indoor/outdoor temperature <Correct line> Refrigerant piping Indoor/outdoor connecting wire A B INDOOR UNIT A A B INDOOR UNIT B OUTDOOR UNIT <Incorrect wiring> A B INDOOR UNIT A A B INDOOR UNIT B OUTDOOR UNIT <Incorrect piping> A B INDOOR UNIT A A B OUTDOOR UNIT INDOOR UNIT B 117 The record of auto line correcting can be confirmed in the following way: Turn OFF the power supply. Turn ON the 4th Dip Switch of SW1 on the display P.C. board. Turn ON the power supply. Confirm the correction by the blinking of LED. Number of blinks LED1 (Red) LED2 (Yellow) Once Once 3 times 3 times SW1 ON Wiring line MXZ-2A Not corrected Corrected Turn OFF the power supply after the confirmation, and turn OFF the 4th Dip Switch of SW1 on the display P.C. board. Turn ON the power supply. NOTE: This function does not work when the jumper wire JGO on the inverter P.C. board is cut. <MXZ-4A80VA- E2 , MXZ-5A100VA> Improper wiring or piping can be automatically detected by pressing the piping/wiring correction switch (SW871). When improper wiring or piping is detected, wiring lines are corrected. This will be completed in about 10 to 15 min. [How to activate this function] 1. Check that outside temperature is above 0°C . (This function does not work when outside temperature is not above 0°C.) 2. Check that the stop valves of the liquid pipe and gas pipe are open. SW871 3. Check that the wiring between indoor and outdoor unit is correct. (If the wiring is not correct, this function does not work.) 4. Turn ON the power supply and wait at least 1 minute. 5. Press the piping/wiring correction switch (SW871) on the electronic control P.C. board. Do not touch energized parts. SW871 LED indication during detection: LED1(Red) LED2(Yellow) LED3(Green) Lighting Lighting Blinking LED indication after detection: LED1(Red) LED2(Yellow) LED3(Green) Indication Lighting Goes out Lighting Completed (Detected successfully) Blinking Blinking Blinking Cannot be corrected Refer to"SAFETY PRECAUTIONS WHEN LED FLASHES" located behind the service panel. Other indications Be sure to check for closed valves, cracked pipes or clogged pipes. 6. Press the switch to cancel. LED indication after cancel: LED1(Red) LED2(Yellow) LED3(Green) Lighting Lighting Goes Out NOTE: Indoor unit cannot be operated while this function is activated. When this function is activated while indoor unit is operating, the operation will be stopped. Operate indoor unit after the auto line correcting is finished. Pressing the switch during detection cancels this function. 118 The record of auto line correcting can be confirmed in the following way: Press the switch for more than 5 sec. LED will show the record of auto correcting for about 30 sec. as shown in the table below: LED1(Red) Once 3 times Number of blinks Wiring line LED2(Yellow) LED3(Green) Once Lighting Not corrected 3 times Lighting Corrected NOTE: Activate this function to confirm the correct wiring after replacing the electronic control P.C. board. (Previous records are deleted when the electronic control P.C. board is replaced.) The record cannot be shown if auto line correcting is not canceled (Refer to "How to activate this function"). 12-5. INCREASING MAXIMUM COMPRESSOR OPERATIONAL FREQUENCY AND FAN SPEED OF THE OUTDOOR UNIT <MXZ-4A80VA- E2 , MXZ-5A100VA> Compressor operational frequency and fan speed can be increased. Capacity of the unit can be improved with this function. NOTE: Compressor operational frequency may not be increased under primary current restriction or high pressure protection. Compressor operational frequency will not be increased when 1 or 2 indoor units are operating. This function doesn't work when the function which lowers the operating noise of the outdoor unit is activated. Noise level of the outdoor unit will increase (You may need to explain this to your customers.) [How to increase maximum compressor operational frequency and fan speed] Turn OFF the power supply for the air conditioner before making the setting. Set the 3rd Dip Switch of SW2 on the outdoor electronic control P.C. board to ON to enable this function. Turn ON the power supply for the air conditioner. SW2 ON 1 2 3 4 5 6 12-6. CHANGING DEFROST FINISH TEMPERATURE AND HEAT OPERATION TIME <MXZ-4A80VA- E2 , MXZ-5A100VA> If defrosting operation starts more than necessary, the defrost finish temperature and heat operation time can be changed. The number of defrosting operation and defrosting time can be reduced with this function. Defrost finish temperature (°C) Heat operation time (min.) Initial setting 10 31 Changed 5 40 [How to change defrost finish temperature and heat operation time] Turn OFF the power supply for the air conditioner before making the setting. Set the 1st Dip Switch of SW2 on the outdoor electronic control P.C. board to ON to enable this function. Turn ON the power supply for the air conditioner. SW2 ON 1 2 3 4 5 6 12-7. CHANGING THE AMPERE LIMIT <MXZ-4A80VA- E2 , MXZ-5A100VA> With this function, you can change the current that flows in the outdoor unit. NOTE: Use this function only when the amount of current exceeds the allowed value. SW 2 MXZ-4A80VA - E2 MXZ-5A100VA ON 10.5A ON [How to change the ampere limit] Be sure to turn OFF the power supply for the air conditioner before making the setting. Make the setting referring to the table on the right. Turn ON the power supply for the air conditioner. 119 15.5A ON Initial setting Full 13 TROUBLESHOOTING MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA 13-1. CAUTIONS ON TROUBLESHOOTING 1. Before troubleshooting, check the following: 1) Check the power supply voltage. 2) Check the indoor/outdoor connecting wire for miswiring. 2. Take care of the following during servicing 1) Before servicing the air conditioner, be sure to turn OFF the unit first with the remote controller, and after confirming the horizontal vane is closed, turn OFF the breaker and/or disconnect the power plug. 2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board. 3) When removing the electrical parts, be careful of the residual voltage of smoothing capacitor. 4) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components. 5) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires. Lead wiring Housing point 3. Troubleshooting procedure 1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality. To make sure, check how many times the abnormality indication is flashing on and off before starting service work. 2) If the electronic control P.C. board seems to be defective, check the copper foil pattern for disconnection and the components for bursting and discoloration. 3) Refer to 13-2, 13-3 and 13-4. 13-2. FAILURE MODE RECALL FUNCTION This air conditioner can memorize the abnormal condition which has occurred once. Even though LED indication listed on the troubleshooting check table (13-4) disappears, the memorized failure details can be recalled. This mode is very useful when the unit needs to be repaired for the abnormality which doesn’t recur. 1. Type of failure mode recall function There are 2 types in failure mode recall function as shown below. Indoor and outdoor unit failure mode recall function With this function, failure mode of indoor unit and a part of failure mode of outdoor unit can be recalled. The details of outdoor unit failure mode recall function With this function, more detailed failure mode of outdoor unit can be recalled. Refer to the service manual of indoor unit for how to recall the failure mode and the details of indoor unit failure mode. The outdoor unit failure mode is indicated by the operation indicator lamp on the indoor unit and the LED of outdoor unit. See "13-2.2. Outdoor unit failure mode table". 120 2. Outdoor unit failure mode table MXZ-2A Upper or left lamp of OPERATION INDICATOR lamp (Indoor unit) Abnormal point (Failure mode / protection) LED indication Condition (Outdoor P.C. board) LED 1 LED 2 Lighting Lighting Lighting Lighting Overcurrent protection stop is continuously performed three times within 1 minute after the compressor gets started. OFF 2-time flash None (Normal) Outdoor power system 3-time flash Discharge temperature thermistor Lighting Once Defrost thermistor Ambient temperature thermistor Fin temperature thermistor P.C. board temperature thermistor Lighting Lighting Lighting Lighting Outdoor heat exchanger temperature thermistor Lighting 9 times 4-time flash Thermistor shorts or opens during compressor running. Once Twice 3 times 4 times • Refer to 13-6. "Check of outdoor thermistors". • Refer to 13-6. "Check of outdoor thermistors". Once Goes out 23 A (MXZ-2A30VA- E1 , MXZ-2A40VA, MXZ-2A52VA)/ 14 A (MXZ-2A30VA- E2 ) current flows into intelligent power module. Compressor Twice 9 times Goes out • Check the connection of the compressor connecting wire. • Refer to 13-6. "How to check inverter/compressor". • Check the stop valve. • Replace the outdoor electronic control P.C. board. Overcurrent Goes out Correspondence The possibility of intercepting the overcurrent by the compressor lock is high. The compressor doesn't synchronize with the operating power. • Reconnect compressor connector. • Refer to 13-6. "How to check inverter/ compressor". • Check the stop valve. • Check the connection of the compressor connecting wire. • Refer to 13-6. "How to check inverter/ compressor". 5-time flash Discharge temperature Lighting Lighting Discharge temperature exceeds 116°C • Check refrigerant circuit during operation. and refrigerant amount. Compressor can restart if discharge • Refer to 13-6. "Check temperature thermistor reads 100°C or of LEV". less 3 minutes later. 6-time flash High pressure Lighting Lighting The outdoor heat exchanger temperature exceeds 70°C during cooling or the indoor gas pipe temperature exceeds 70°C during heating. • Check refrigerant circuit and refrigerant amount. • Check the stop valve. 7-time flash Fin temperature 3 times Goes out The fin temperature exceeds 90°C during operation. P.C. board temperature 4 times Goes out The P.C. board temperature exceeds 78°C during operation. • Check around outdoor unit. • Check outdoor unit air passage. • Refer to 13-6. "Check of outdoor fan motor". 8-time flash Outdoor fan motor Lighting Lighting Failure occurs continuously three times within 30 seconds after the fan gets started. 9-time flash Nonvolatile memory data Lighting 5 times Nonvolatile memory data cannot be read properly. 10-time flash Discharge temperature • Refer to 13-6. "Check of outdoor fan motor". • Replace the outdoor electronic control P.C. board. Lighting Lighting The frequency of the compressor is • Check refrigerant circuit kept 68 Hz (MXZ-2A30VA, MXZand refrigerant amount. 2A40VA- E2 )/ 80Hz (MXZ-2A40VA- E1 , • Refer to 13-6. "Check MXZ-2A52VA) or more and the of LEV". discharge temperature is kept under 50°C (COOL mode)/40°C (HEAT mode) for more than 40 minutes. NOTE: Blinking patterns of this mode differ from the ones of Troubleshooting check table (13-4). 121 Indoor/outdoor unit failure mode recall function Upper or left lamp of OPERATION INDICATOR lamp (Indoor unit) 11-time flash 14-time flash 15-time flash Abnormal point (Failure mode / protection) LED indication (Outdoor P.C. board) LED 1 LED 2 Condition Correspondence Current sensor 8 times Goes out A short or open circuit is detected in the current sensor during compressor operating. • Replace the power board. Bus-bar voltage 6 times Goes out The bus-bar voltage exceeds 430 V or falls to 50 V or below during compressor operating. • Replace the power board. Power module 7 times Goes out There is a high possibility that the power module is out of order. • Refer to 13-6. "How to check inverter/ compressor". Stop valve (Closed valve) Lighting 12 times Closed valve is detected by compressor • Check the stop valve. current. (MXZ-2A30VA, MXZ-2A40VA - E2 ) LEV for drain Lighting Lighting The indoor unit detects any abnormalities in the LEV for drain. • Refer to 13-6. "Check of LEV". • Check the drain pump of the indoor unit. NOTE: Blinking patterns of this mode differ from the ones of Troubleshooting check table (13-4). 122 Indoor/outdoor unit failure mode recall function MXZ-3A/4A/5A Upper or left lamp of OPERATION INDICATOR lamp (Indoor unit) Abnormal point (Failure mode / protection) LED indication Condition (Outdoor P.C. board) LED 1 LED 2 Lighting Lighting Lighting Lighting Overcurrent protection stop is continuously performed three times within 1 minute after the compressor gets started, or converter protection stop or bus-bar voltage protection stop is continuously performed three times within 3 minutes after start-up. OFF 2-time flash None (Normal) Outdoor power system 3-time flash Discharge temperature thermistor Lighting Once Defrost thermistor Ambient temperature thermistor Fin temperature thermistor P.C. board temperature thermistor Lighting Lighting Lighting Lighting Outdoor heat exchanger temperature thermistor Lighting 9 times Gas pipe temperature thermistor A Gas pipe temperature thermistor B Gas pipe temperature thermistor C Gas pipe temperature thermistor D Lighting 10 times A short or open circuit is detected in the thermistor during cooling. Lighting 11 times (A,B,C : MXZ-3A54VA- E1 , E2 , E3 MXZ-4A71VA- E1 , E2 , E3 MXZ-4A80VA- E1 ) Lighting 12 times (D : MXZ-4A71VA- E1 , E2 , E3 MXZ-4A80VA- E1 ) Lighting 13 times Thermistor shorts or opens during compressor running. Once Twice 3 times 4 times Correspondence • Check the connection of the compressor connecting wire. • Refer to 13-6. "How to check inverter/compressor". • Check the stop valve. • Refer to 13-6. "Check of outdoor thermistors". • Replace the outdoor electronic control P.C. board. • Refer to 13-6. "Check of outdoor thermistors". 4-time flash Overcurrent 5-time flash Discharge temperature Lighting Lighting Discharge temperature exceeds 116°C • Check refrigerant circuit during operation. and refrigerant amount. Compressor can restart if discharge • Refer to 13-6. "Check temperature thermistor reads 100°C or of LEV". less 3 minutes later. 6-time flash High pressure Lighting Lighting High-pressure is detected with the high-pressure switch (HPS) during operation. (MXZ-4A80VA, MXZ-5A100VA) The outdoor heat exchanger temperature exceeds 70°C during cooling or the indoor gas pipe temperature exceeds 70°C during heating. 3 times Goes The fin temperature exceeds 89°C out during operation. 7-time flash Fin temperature Once Goes out 28A current flows into intelligent power • Reconnect compressor module. connector. • Refer to 13-6. "How to check inverter/ compressor". • Check the stop valve. P.C. board temperature 4 times 8-time flash Outdoor fan motor Lighting Lighting Failure occurs continuously three times within 30 seconds after the fan gets started. 9-time flash Nonvolatile memory data Lighting 5 times Nonvolatile memory data cannot be read properly. 10-time flash Discharge temperature Goes out The P.C. board temperature exceeds 73°C (MXZ-3A54VA, MXZ-4A71VA)/ 87°C (MXZ-4A80VA, MXZ-5A100VA) during operation. • Check refrigerant circuit and refrigerant amount. • Check the stop valve. • Check around outdoor unit. • Check outdoor unit air passage. • Refer to 13-6. "Check of outdoor fan motor". • Refer to 13-6. "Check of outdoor fan motor". • Replace the outdoor electronic control P.C. board. Lighting Lighting The frequency of the compressor is • Check refrigerant circuit and refrigerant amount. kept 80Hz or more and the discharge • Refer to 13-6. "Check temperature is kept under 50°C (COOL mode)/40°C (HEAT mode) of LEV". for more than 40 minutes. NOTE: Blinking patterns of this mode differ from the ones of Troubleshooting check table (13-4). 123 Indoor/outdoor unit failure mode recall function Upper or left lamp of OPERATION INDICATOR lamp (Indoor unit) 11-time flash LED indication (Outdoor P.C. board) LED 1 LED 2 Abnormal point (Failure mode / protection) Correspondence Condition Communication error between P.C. boards Lighting 6 times Communication error occurs between the electronic control P.C. board and power board for more than 10 seconds. The communication between boards protection stop is continuously performed twice. Current sensor Lighting 7 times Zero cross detecting circuit 5 times A short or open circuit is detected in the current sensor during compressor operating. Current sensor protection stop is continuously performed twice. Zero cross signal cannot be detected while the compressor is operating. Goes out The protection stop of the zero cross detecting circuit is continuously performed 10 times. 15-time flash Indoor/outdoor unit failure mode recall function • Check the connecting wire between outdoor electronic control P.C. board and power board. • Replace the power board. • Check the connecting wire among electronic control P.C. board, noise filter P.C. board and power board. • Check the voltage of power supply. • Replace the power board. Converter 5 times Goes out A failure is detected in the operation of the converter during operation. Bus-bar voltage (1) 5 times Goes out The bus-bar voltage exceeds 400 V or falls to 200 V or below during compressor operating. Bus-bar voltage (2) Even if this protection stop is performed continuously three times, it does not mean the abnormality in outdoor power system. 6 times Goes out The bus-bar voltage exceeds 400 V (MXZ-3A54VA, MXZ-4A71VA)/ 430 V (MXZ-4A80VA, MXZ-5A100VA) or falls to 50V or below during compressor operating. • Check the voltage of power supply. • Replace the outdoor electronic control P.C. board. LEV for drain Lighting Lighting The indoor unit detects any abnormalities in the LEV for drain. • Refer to 13-6. "Check of LEV". • Check the drain pump of the indoor unit. NOTE: Blinking patterns of this mode differ from the ones of "Troubleshooting check table" (13-4). 13-3. INSTRUCTION OF TROUBLESHOOTING • Check the indoor unit with referring to the indoor unit service manual, and confirm whether there is any problem in the indoor unit. Then, check the outdoor unit with referring to this page. Operation start Check the outdoor unit LED indicator. Both LED 1 and LED 2 are OFF. LED 1 or LED 2 has blinked. Both LED 1 and LED 2 are lighting. Refer to 13-4. "Troubleshooting check table". Refer to 13-6. "Check of power supply". • Indoor unit serial signal error Refer to 13-6. "How to check miswiring and serial signal error". • COOL or HEAT operation only Refer to 13-6. "Check of R.V. coil". • When cooling, heat exchanger of non-operating indoor unit frosts. •When heating, nonoperating indoor unit gets warm. Refer to 13-6. "Check of LEV". • When cooling, dew drops in the non-operating indoor unit. Check of mispiping 124 • When heating, room does not get warm. Refer to 13-6. "How to check of inverter/compressor". Check mispiping, shortage of capacity • When cooling, room does not cool. Refer to 13-6. "How to check of inverter/ compressor". 13-4. TROUBLESHOOTING CHECK TABLE MXZ-2A No. Symptom Outdoor unit 1 does not operate. Indication LED1(Red) LED2(Yellow) Lighting Once Abnormal point / Condition LEV for drain 2 Lighting Twice Outdoor power system 3 Lighting 3 times Discharge temperature thermistor 4 Lighting 5 Lighting 4 times 5 times Fin temperature thermistor P.C board temperature thermistor Ambient temperature thermistor Condition The indoor unit detects any abnormality in the LEV for drain. Overcurrent protection stop is continuously performed three times within 1 minute after the compressor gets started. Correspondence • Refer to 13-6 "Check of LEV". • Check the drain pump of the indoor unit. • Check the connection of the compressor connecting wire. • Refer to 13-6. "How to check inverter/compressor". • Check the stop valve. A short circuit is detected in the thermistor during operation, or when an open circuit is detected in the thermistor after 10 minutes of compressor • Refer to 13-6. "Check of outdoor thermistors". start-up. • Refer to 13-6. "Check of outdoor thermistors". A short or open circuit is detected in the thermistor during operation. • Replace the outdoor electronic control P.C. board. A short or open circuit is detected in the thermistor during operation. Outdoor heat exchanger temperature thermistor A short circuit is detected in the thermistor during operation, or when an open circuit is detected in the thermistor after 5 minutes (in cooling) and 10 minutes (in heating) of compressor start-up. Defrost thermistor A short circuit is detected in the thermistor during operation, or when an open circuit is detected in the thermistor after 5 minutes of compressor start-up. • Refer to 13-6. "Check of outdoor thermistors". 6 Lighting 7 times Nonvolatile memory data The nonvolatile memory data cannot be read properly. • Replace the outdoor electronic control P.C. board. 7 Lighting 11 times Stop valve Closed valve Closed valve is detected by compressor current. (MXZ-2A30VA, MXZ-2A40VA - E2 ) • Check the stop valve. Overcurrent Twice Goes out 23 A (MXZ-2A30VA- E1 , MXZ-2A40VA, MXZ-2A52VA)/ 14 A (MXZ-2A 30VA- E2 )current flows into intelligent power module. 3 times Goes out Discharge temperature protection Discharge temperature exceeds 116°C during operation. Compressor can • Check the amount of gas and refrigerant circuit. restart if discharge temperature thermistor reads 100°C or less 3 minutes • Refer to 13-6. "Check of LEV". later. 4 times Goes out Fin temperature protection P.C. board temperature protection 8 'Outdoor unit stops and restarts 3 minutes later' is repeated. 9 10 11 5 times Goes out High-pressure protection 12 9 times Goes out Bus-bar voltage protection 13 13 times Goes out Outdoor fan motor 14 8 times Goes out Current sensor protection 15 10 times Goes out Compressor Once Lighting 16 Outdoor unit operates. Primary current protection The fin temperature exceeds 90°C during operation. Twice Lighting The outdoor heat exchanger temperature exceeds 70°C during cooling or indoor gas pipe temperature exceeds 70°C during heating. • Check the amount of gas and the refrigerant circuit. • Check the stop valve. The bus-bar voltage exceeds 430 V or falls to 50 V or below during compressor operating. Failure occurs continuously three times within 30 seconds after the fan gets started. A short or open circuit is detected in the current sensor during compressor operating. • Replace the power board. • Refer to 13-6. The compressor doesn't synchronize with the operating power. • Reconnect compressor connector. • Refer to 13-6. "How to check inverter/compressor". • Check the stop valve. The input current exceeds 8 A (MXZ-2A30VA)/ 10 A (MXZ-2A40VA, MXZ-2A52VA). High-pressure protection The indoor gas pipe temperature exceeds 45°C during heating. Defrosting in cooling The indoor gas pipe temperature falls 3°C or below during cooling. The discharge temperature exceeds 100°C during operation. 18 3 times Lighting Discharge temperature protection 19 4 times Lighting Low discharge temperature protection • Check refrigerant circuit and refrigerant amount. • Refer to 13-6. "Check of outdoor fan motor". The P.C. board temperature exceeds 78°C during operation. Secondary current protection The current of the compressor exceeds 17 A. 17 • Reconnect compressor connector. • Refer to 13-6. "How to check inverter/compressor". • Check the stop valve. "Check of outdoor fan motor". • Replace the power board. These symptoms do not mean any abnormality of the product, but check the following points. • Check if indoor filters are clogged. • Check if refrigerant is short. • Check if indoor/outdoor unit air circulation is short cycled. • Check refrigerant circuit and refrigerant amount. • Refer to 13-6. "Check of LEV". • Refer to 13-6. "Check of outdoor thermistors". The frequency of the compressor is kept 80 Hz or more and the discharge • Refer to 13-6. "Check of LEV". temperature is kept under 50°C (COOL mode)/40°C (HEAT mode) for • Check refrigerant circuit and refrigerant amount. more than 40 minutes. 125 No. Symptom Indication Abnormal point / Condition LED1(Red) LED2(Yellow) Outdoor unit operates. 20 5 times Lighting Cooling high-pressure protection Outdoor unit 21 operates normally. 9 times Lighting Inverter check mode 22 Lighting Lighting Normal Condition Correspondence This symptom does not mean any abnormality of the product, but check the following points. The outdoor heat exchanger temperature exceeds 58°C during operation. • Check if indoor filters are clogged. • Check if refrigerant is short. • Check if indoor/outdoor unit air circulation is short cycled. The unit is operated with emergency operation switch. - - - Display P.C. board(Parts side) NOTE 1. The location of LED is illustrated at the right figure. Refer to 13-7.6. 2. LED is lighted during normal operation. The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF. (Example) When the flashing frequency is “2”. 0.5-second ON ON OFF 2.5-second OFF 2.5-second OFF 126 LED1 LED2 Lighting 0.5-second ON MXZ-3A/4A/5A No. Symptom Outdoor unit does not operate. Indication LED1(Red) LED2(Yellow) Abnormal point / Condition Condition Correspondence Lighting Once LEV for drain • Refer to 13-6. "Check of LEV". The indoor unit detects any abnormality in the LEV for drain. • Check the drain pump of the indoor unit. 2 Lighting Twice Outdoor power system • Check the connection of the compressor connecting Overcurrent protection stop is continuously performed three times within 1 minute after the compressor gets started, or converter protection wire. • Refer to 13-6. "How to check inverter/compressor". stop or bus-bar voltage protection stop is continuously performed three • Check the stop valve. times within 3 minutes after start-up. 3 Lighting 3 times Discharge temperature thermistor 4 Lighting 4 times 1 5 Lighting Fin temperature thermistor P.C board temperature thermistor Ambient temperature thermistor • Replace the outdoor electronic control P.C. board. Current sensor protection stop is continuously performed twice. • Replace the power board. 8 times Current sensor Gas pipe temperature thermistor A Gas pipe temperature thermistor B Gas pipe temperature thermistor C Gas pipe temperature thermistor D 10 Lighting 12 times Twice Goes out 11 'Outdoor unit stops and restarts 3 minutes later' is repeated. 12 3 times Goes out 13 4 times Goes out 14 5 times Goes out 15 8 times Goes out 16 17 18 Overcurrent is detected after 30 minutes of compressor start-up. Lock protection Overcurrent is detected within 30 minutes of compressor start-up Discharge temperature protection Discharge temperature exceeds 116°C during operation. Compressor can • Check the amount of gas and refrigerant circuit. restart if discharge temperature thermistor reads 100°C or less 3 minutes • Refer to 13-6. "Check of LEV". later. Fin temperature protection P.C. board temperature protection High-pressure protection Lighting 12 times •Check refrigerant circuit and refrigerant amount. •Refer to 13-6. "Check of outdoor fan motor". The P.C. board temperature exceeds 73°C (MXZ-3A54VA, MXZ-4A71VA)/ 87°C (MXZ-4A80VA, MXZ-5A100VA) during operation. High-pressure is detected with the high-pressure switch (HPS) during • Check the amount of gas and the refrigerant circuit. operation. (MXZ-4A80VA, MXZ-5A100VA) • Check the stop valve. A failure is detected in the operation of the converter during operation. • Replace the power board. Bus-bar voltage protection (1) The bus-bar voltage exceeds 400 V or falls to 200 V or below during compressor operating. The bus-bar voltage exceeds 400 V (MXZ-3A54VA, MXZ-4A71VA)/ 430 V (MXZ-4A80VA, MXZ-5A100VA) or falls to 50 V or below during compressor operating. • Check the voltage of power supply. • Replace the power board or the outdoor electronic control P.C. board. • Refer to 13-6. “Check of bus-bar voltage”. Outdoor fan motor 20 The fin temperature exceeds 89°C during operation. Converter protection Goes out 11 times • Reconnect compressor connector. • Refer to 13-6. "How to check inverter/compressor". • Check the stop valve. • Check the power module (PAM module). The outdoor heat exchanger temperature exceeds 70°C during cooling or indoor gas pipe temperature exceeds 70°C during heating. 13 times Lighting • Refer to 13-6. "Check of outdoor thermistors". IPM protection Bus-bar voltage protection (2) 19 "Check of outdoor thermistors". Communication error occurs twice between the outdoor electronic control • Check the connecting wire between outdoor electronic control P.C. board and power board for more than 10 seconds. P.C. board and power board. • Check the connecting wire among outdoor electronic control The protection stop of the zero cross detecting circuit is continuously P.C. board, noise filter P.C. board and power board. performed 10 times. Goes out 8 times A short or open circuit is detected in the thermistor during cooling. (A,B,C : MXZ-3A54VA- E1 , E2 , E3 , MXZ-4A71VA- E1 , E2 , E3 MXZ-4A80VA- E1 ) (D : MXZ-4A71VA- E1 , E2 , E3 , MXZ-4A80VA- E1 ) • Refer to 13-6. Communication error between P.C. boards Zero cross detecting circuit 9 times Lighting A short or open circuit is detected in the thermistor during operation. The nonvolatile memory data cannot be read properly. Lighting 11 times • Replace the outdoor electronic control P.C. board. Nonvolatile memory data 7 Lighting "Check of outdoor thermistors". A short circuit is detected in the thermistor during operation, or an open circuit is detected in the thermistor after 5 minutes of compressor start-up. 7 times 9 • Refer to 13-6. A short or open circuit is detected in the thermistor during operation. Defrost thermistor Lighting 10 times "Check of outdoor thermistors". A short circuit is detected in the thermistor during operation, or an open circuit is detected in the thermistor after 5 minutes (in cooling) and 10 minutes (in heating) of compressor start-up. 6 Lighting • Refer to 13-6. Outdoor heat exchanger temperature thermistor 5 times 8 A short circuit is detected in the thermistor during operation, or an open circuit is detected in the thermistor after 10 minutes of compressor start-up. Current sensor protection Failure occurs continuously three times within 30 seconds after the fan gets started. A short or open circuit is detected in the current sensor during compressor operating. Communication error occurs between the outdoor electronic control P.C. board and power board for more than 10 seconds. Communication protection between P.C. boards Zero cross detecting circuit Zero cross signal cannot be detected while the compressor is operating. protection 127 • Refer to 13-6. "Check of outdoor fan motor". • Replace the power board. • Check the connecting wire between outdoor electronic control P.C. board and power board. • Check the connecting wire among outdoor electronic control P.C. board, noise filter P.C. board and power board. No. Symptom Indication LED1(Red) LED2(Yellow) Outdoor unit operates. 21 Twice Lighting The input current exceeds 15 A (MXZ-3A54VA, MXZ-4A71VA)/ 17 A (MXZ-4A80VA)/18 A (MXZ-5A100VA). High-pressure protection Defrosting in cooling The indoor gas pipe temperature falls 3°C or below during cooling. Lighting Secondary current protection 22 Correspondence These symptoms do not mean any abnormality of the product, but check the following points. The current of the compressor exceeds 12 A (MXZ-3A54VA, MXZ-4A71VA)/ • Check if indoor filters are clogged. • Check if refrigerant is short. 10 A (MXZ-4A80VA, MXZ-5A100VA). • Check if indoor/outdoor unit air circulation is short cycled. The indoor gas pipe temperature exceeds 45°C during heating. Primary current protection Once Condition Abnormal point / Condition • Check refrigerant circuit and refrigerant amount. • Refer to 13-6. "Check of LEV". • Refer to 13-6. "Check of outdoor thermistors". 23 3 times Lighting Discharge temperature protection The discharge temperature exceeds 100°C during operation. 24 4 times Lighting Low discharge temperature protection The frequency of the compressor is kept 80 Hz or more and the discharge • Refer to 13-6. "Check of LEV". temperature is kept under 50°C (COOL mode) /40°C (HEAT mode) for • Check refrigerant circuit and refrigerant amount. more than 40 minutes. 5 times Lighting Cooling high-pressure protection This symptom does not mean any abnormality of the product, but check the following points. The outdoor heat exchanger temperature exceeds 58°C during operation. • Check if indoor filters are clogged. • Check if refrigerant is short. • Check if indoor/outdoor unit air circulation is short cycled. 9 times Lighting Inverter check mode The unit is operated with emergency operation switch. Lighting Lighting Normal 25 26 Outdoor unit operates normally. 27 - - - NOTE 1. The location of LED is illustrated at the right figure. Refer to 13-7.2. 2. LED is lighted during normal operation. Outdoor electronic control P.C. board(Parts side) MXZ-3A54VA, MXZ-4A71VA, MXZ-4A80VA- E1 The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF. (Example) When the flashing frequency is “2”. LED2 LED1 Lighting 0.5-second ON 0.5-second ON MXZ-4A80VA- E2 , MXZ-5A100VA LED1 LED2 ON OFF 2.5-second OFF 2.5-second OFF Lighting 128 13-5. TROUBLE CRITERION OF MAIN PARTS MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA Part name Defrost thermistor (RT61) Check method and criterion Fin temperature thermistor (RT64) Measure the resistance with a tester. Ambient temperature thermistor (RT65) Refer to 13-7. “Test point diagram and voltage”, 1. “Inverter P.C. board” , 2. “Outdoor electronic control P.C. board” or 5. “Outdoor Power board”, for the chart of thermistor. Outdoor heat exchanger temperature thermistor (RT68) Gas pipe temperature thermistor (RT6A~D) MXZ-3A54VA- E1 , E2 , E3 MXZ-4A71VA- E1 , E2 , E3 MXZ-4A80VA- E1 Measure the resistance with a tester. Before measurement, hold the thermistor with your hands to warm it up. Discharge temperature thermistor (RT62) Refer to 13-7. “Test point diagram and voltage”, 1. “Inverter P.C. board” or 2. “Outdoor electronic control P.C. board”, for the chart of thermistor. Compressor W Measure the resistance between terminals using a tester. (Winding temperature : -10°C ~ 40°C) RED V WHT 2A30VA 2A40VA- U BLK 1.49 Outdoor fan motor WHT 2 RED WHT BLK U MXZ-2A 0.56 ~ 0.69 0.39 ~ 0.49 3A54VA 4A71VA - 0.86 , , , , , , 4A80VA 5A100VA E4 E5 E6 E7 E4 E5 E6 E7 ~ 1.06 1.29 Normal (Each phase) U (W) 1 W V ~ 1.84 Normal (Each phase) 3A54VA - E1 , E2 , E3 E1 4A71VA - E1 , E2 , E3 Measure the resistance between lead wires using a tester. (Part temperature : -10°C ~ 40°C) RED BLK 3 E2 2A40VA2A52VA V (V) W (U) MXZ-3A/4A/5A MXZ-2A 12 13.4 ~ 16 ~ 16.4 MXZ-3A/4A/5A Measure the resistance using a tester. (Part temperature : -10°C ~ 40°C) Normal (Each phase) R.V. coil MXZ-3A54VA MXZ-4A71VA - E4 E4 , E5 , E6 , E7 , E5 , E6 , E7 1.2 k ~ 1.56 k 1.26 k ~ 1.62 k Linear expansion valve WHT RED LEV ORN Other models Measure the resistance using a tester. (Part temperature : -10°C ~ 40°C) Normal Color of lead wire WHT - RED RED - ORN YLW - BRN BRN - BLU 37.4 ~ 53.9 YLW BRN BLU High pressure switch (HPS) MXZ-4A80/5A100 Pressure 3.7 0.15 MPa 0.05 4.8 + MPa - 0.1 HPS 129 Normal Close Open ~ 1.49 13-6. TROUBLESHOOTING FLOW Outdoor unit does not operate. Check of power supply MXZ-2A30/2A40/2A52 Check the connecting of parts of main power supply circuit. Turn ON the power supply. Is there voltage of 230V AC in the power supply terminal block? No Check the power supply cable. Yes Is the output voltage from the power P.C. board 230V AC? No Is fuse (F61 or F64) blown? No Replace the power P.C. board. Yes Yes Is the input voltage to the inverter P.C. board 230V AC? Replace the fuse. No Replace the reactor. Yes Replace the inverter P.C. board. MXZ-3A54/4A71/4A80/5A100 Check the connecting of parts of main power supply circuit. Turn ON the power supply. Is there voltage of 230V AC in the power supply terminal block? No Check the power supply cable. Yes Is the output voltage from the noise filter P.C. board 230V AC? No Is fuse (F64) blown? No Yes Yes Is the input voltage to the power board 230V AC? Replace the fuse. No Replace the reactor. Yes No Is the input voltage to the outdoor electronic control P.C. board 325V DC? Replace the power board. Yes Replace the outdoor electronic control P.C. board. 130 Replace the noise filter P.C. board. • When unit cannot operate neither by the remote controller nor by EMERGENCY OPERATION switch. Indoor unit does not operate. • When OPERATION INDICATOR lamp flashes ON and OFF in every 0.5-second. Outdoor unit does not operate. How to check mis-wiring and serial signal error (when outdoor unit does not work) LED indication for communication status Communication status is indicated by the LED. Turn OFF the power supply. Unit status Blinking: normal communication Lighting: abnormal communication or not connected Pattern 1 and 2 is repeatedly displayed alternately. Each pattern is displayed for 15 seconds. NOTE: "Lighting" in the table below does not indicate abnormal communication. Is there rated voltage in the power supply? Check the power supply. Yes Turn ON the power supply. Is there rated voltage between outdoor terminal block S1 and S2? MXZ-2A52VA No Check the wiring. Yes Outdoor display P.C. board Press EMERGENCY OPERATION switch once. LED1 LED2 Does the left lamp of OPERATION INDICATOR lamp light up? <Confirmation of the power to the indoor unit> Blinking LED 1 Unit A status No LED 2 Unit B status No Yes Is serial signal error indicated 6 minutes later? MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA - E1 No Yes Is there any miswiring, poor contact, or wire disconnection of the indoor/outdoor connecting wire? Yes Correct them. No Outdoor electronic control P.C. board (Parts side) A LED3 LED2 LED1 Blinking Pattern LED 3 1 Lighting 2 Goes out LED 2 LED 1 Unit B status Unit D status Unit A status Unit C status Turn OFF the power supply. Check once more if the indoor/outdoor B connecting wire is not miswiring. Short-circuit outdoor terminal block S2 and S3. 1 1. Miswiring may damage indoor electronic control P.C. board during the operation. Be sure to confirm the wiring is correct before the operation starts. Turn ON the power supply. MXZ-4A80VA - E2 MXZ-5A100VA Outdoor electronic control P.C. board (Parts side) Does the LED on the outdoor display P.C. board or the outdoor electronic control P.C. board repeat "3.6-second-OFF and 0.8-second-ON quick blinking"? LED1 LED2 LED3 No (Lighted or not lighted) Blinking Yes Pattern LED 1 LED 2 LED 3 1 Unit A status Unit D status Unit B status Unit E status Unit C status 2 Goes out A · Turn OFF inverter-controlled lighting equipment. · Turn OFF the power supply and turn ON again. · Press EMERGENCY OPERATION switch. Is serial signal error indicated 6 minutes later? Yes B · Reinstall either the unit or the light away from each No other. · Attach a filter on remote control receiving section of the indoor unit. Turn OFF the power supply. Remove the short-circuit between outdoor terminal block S2 and S3. Turn ON the power supply. Is there amplitude of 10 to 20V DC between outdoor terminal block S2 and S3? <Confirmation of serial signal> No Replace the inverter P.C. board or the outdoor electronic control P.C. board. 2 2 Be careful of residual voltage of smoothing capacitor. Is there any error of the indoor/outdoor connecting wire, such as the damage of the wire, intermediate connection, poor contact to the terminal block? Yes Replace the indoor/outdoor connecting wire. Yes Replace the indoor/outdoor connecting wire. No Yes Is there rated voltage between indoor terminal block S1 and S2? <Confirmation of power voltage> No Is there any error of the indoor/outdoor connecting wire, such as the damage of the wire, intermediate connection, poor contact to the terminal block? Yes No Replace the indoor electronic control P.C. board. Be sure to release the failure-mode recall function after checking. Refer to indoor unit service manual. 131 The cooling operation or heating operation does not operate. Check of R.V. coil MXZ-2A CN912 Power P.C. board CN781 MXZ-3A/4A/5A Noise filter P.C. board Outdoor electronic control P.C. board CN933 Inverter P.C. board • When heating operation does not work. 1. Disconnect the lead wire leading to the compressor. 2. 3 minutes after turning ON the power supply, start EMERGENCY OPERATION in HEAT mode. Is there voltage of 230V AC between pin1 and pin 2 at connector CN912? 1. Turn OFF the power supply of indoor and outdoor unit, and disconnect the connector CN933 or CN781. 2. 3 minutes after turning ON the power supply, start EMERGENCY OPERATION in HEAT mode. No Yes Turn OFF the power supply of indoor and outdoor unit. Disconnect the connector CN912. Is there normal resistance to R.V. coil? (Refer to 13-5.) No Is there voltage 12V DC between the connector CN933 No pin 1 (+) and pin 3 (-) or the connector CN781 pin 5 (+) and pin 3 (-) ? Replace the R.V. coil. Yes Replace the inverter P.C. board or the electronic control P.C. board. Yes Replace the power P.C. board or the noise filter P.C. board. Replace the 4-way valve. • When cooling operation does not work. 1. Disconnect the lead wire leading to the compressor. 2. 3 minutes after turning ON the power supply, start EMERGENCY OPERATION in COOL mode. Is there voltage of 230V AC between pin1 and pin 2 at connector CN912? Yes No Replace the 4-way valve. If the connector CN912 is not connected or R.V. coil is open, voltage occurs between terminals even when the control is OFF. 1. Turn OFF the power supply of the indoor and the outdoor unit, and disconnect the connector CN933 or CN781. 2. 3 minutes after turning ON the power supply, start EMERGENCY OPERATION in COOL mode. Is there voltage 12V DC between the connector CN933 pin 1 (+) and pin 3 (-) or the connector CN781 pin 5 (+) and pin 3 (-) ? No Replace the power P.C.board or the noise filter P.C. board. Yes Replace the inverter P.C. board or the outdoor electronic control P.C. board. 132 • When cooling, heat exchanger of non-operating indoor unit frosts. • When heating, non-operating indoor unit gets warm. Check of LEV Turn ON the power supply to the outdoor unit after checking LEV coil is mounted to the LEV body securely. Yes Is "click - click" sound heard? Or, do you feel vibration of LEV coil with your hand? Normal No Disconnect the connectors. CN791: LEV A, CN792: LEV B, CN793: LEV C, CN794: LEV D, CN795: LEV E, CN796: LEV F. Is there normal resistance to LEV coil? (Refer to 13-5.) No Yes Replace the inverter P.C. board or the outdoor electronic control P.C. board. Replace LEV coil. 133 • When heating, room does not get warm. • When cooling, room does not get cool. How to check inverter/ compressor Disconnect the terminal of the compressor. 3 minutes after turning ON the power supply, start EMERGENCY OPERATION. Measure the voltage between each lead wire leading to the compressor. U (BLK) - V (WHT) V (WHT) - W (RED) W (RED) - U (BLK) Output voltage COOL: 150V (48Hz) HEAT: 170V (64Hz) Is voltage output? 1, 2 1 After the outdoor fan starts running, wait for 1 minute or more before measuring the voltage. The output voltage values have the tolerance of ± 20%. 2 The output differs depending on the capacity or the number of indoor units to be operated. No Yes (MXZ-2A) Yes Is output balanced? No Yes (MXZ-3A/4A/5A) Is the input voltage to the outdoor electronic control P.C. board 370V or more? No Replace the inverter P.C. board or the power board. Yes Turn OFF the power supply of indoor and outdoor unit, and measure the compressor winding resistance between the compressor terminals. Is there resistance between each terminal normal? (Refer to 13-5.) Yes No Reconnect the lead wire of compressor, and turn ON the power supply to indoor and outdoor unit. 3 minutes later, start EMERGENCY OPERATION. Clarify the causes by counting time until the inverter stops. 0 to 10 seconds: compressor layer short 10 to 60 seconds: compressor lock 60 seconds to 5minutes: refrigerant circuit defective 5 minutes or more: normal 134 Replace the compressor. • When thermistor is abnormal. Check of outdoor thermistors Disconnect the connector in the following table and measure the resistance of the thermistor to check whether the thermistor is normal or not. (Refer to 13-7.) Abnormal Replace the thermistor except RT64. In case that RT64 is abnormal, replace the inverter P.C. board or the outdoor power board since RT64 is combined with the inverter P.C. board or the outdoor power board. Normal Reconnect the connector in the following table and disconnect the lead wire leading to the compressor. 3 minutes after turning ON the power supply, start EMERGENCY OPERATION. Does the unit operate 10 minutes or more without showing thermistor abnormality? No Yes Replace the inverter P.C. board, the outdoor electronic control P.C. board, or the outdoor power board. Normal MXZ-2A30/2A40/2A52 Thermistor Defrost Discharge temperature Outdoor heat exchanger temperature Fin temperature Ambient temperature Symbol RT61 RT62 RT68 RT64 RT65 Connector, Pin No. Between CN661 pin1 and pin2 Between CN661 pin3 and pin4 Between CN661 pin5 and pin6 Between CN662 pin1 and pin2 Between CN663 pin1 and pin2 Board Inverter P.C. board MXZ-3A54/4A71/4A80/5A100 Board Connector, Pin No. Thermistor Symbol RT61 Between CN661 pin1 and pin2 Defrost RT62 Between CN661 pin3 and pin4 Discharge temperature RT68 Between CN661 pin7 and pin8 Outdoor heat exchanger temperature RT6A Between CN662 pin1 and pin2 Gas pipe temperature (Unit A) Outdoor electronic control P.C. board RT6B Between CN662 pin3 and pin4 Gas pipe temperature (Unit B) RT6C Between CN662 pin5 and pin6 Gas pipe temperature (Unit C) RT6D Between CN662 pin7 and pin8 Gas pipe temperature (Unit D) RT65 Between CN663 pin1 and pin2 Ambient temperature Outdoor power board RT64 Between CN3 pin1 and pin2 Fin temperature Except MXZ-3A54VA- E4, E5 , E6 , E7 , MXZ-4A71VA- E4 , E5 , E6 ,E7 , MXZ-4A80VA- E2 and MXZ-5A100VA. 135 • Fan motor does not operate or stops operating shortly after starting the operation. Check of outdoor fan motor Disconnect CN932 from the inverter P.C. board or the outdoor electronic control P.C. board, and measure the resistance of the outdoor fan motor. Is the resistance of outdoor fan motor normal? (Refer to 13-5.) Yes No Turn ON the power supply. Rotate the outdoor fan motor manually and measure the voltage of CN931. Between (+) and (-) Between (+) and (-) Between (+) and (-) (Fixed to either 5V or 0V DC) No No Replace the outdoor fan motor. Does the voltage between each terminal become 5V DC and 0V DC repeatedly? Yes Does the outdoor fan motor rotate smoothly? Yes Replace the inverter P.C. board or the outdoor electronic control P.C. board. 136 • When the operation frequency does not go up from lowest frequency. Check of HPS MXZ-4A80VA/5A100VA 1. Disconnect the connector CN681 in the electronic control P.C. board. 2. Check the resistance of HPS 1 minute after the outdoor unit power supply was turned OFF. Infinity Check the resistance between each terminal. Replace HPS. 0Ω Reconnect CN681. Turn ON the power supply to the indoor and outdoor unit. 3 minutes later, start EMERGENCY OPERATION. Is HPS protection displayed immediately after compressor starts? Yes Replace the electronic control P.C. board. No Normal The other cases Indoor unit does not operate. (different operating models in multi system) • When you try to run two indoor units simultaneously, one for cooling and the other for heating, the unit which transmits signal to the outdoor unit first decides the operation mode. • When the above situation occurs, set all the indoor units to the same mode, turn OFF the indoor units, then turn them back ON. • Though the top of the indoor unit sometimes gets warm, this does not mean malfunction. The reason is that the refrigerant gas continuously flows into the indoor unit even while it is not operating. Check of bus-bar voltage MXZ-3A/4A/5A •Check the voltage of power supply. •Confirm outdoor unit failure mode recall function. (Refer to 13-2.2.) Confirm LED1 indication lamp on the outdoor electronic control P.C. board. Blink 5 times Replace the power board. Blink 6 times Replace the outdoor electronic control P.C. board. Turn ON power supply. Start operation. Confirm LED1 indication lamp on the outdoor electronic control P.C. board. Blink 9 times Lighting Replace the outdoor electronic control P.C. board. Turn ON power supply. Start operation. Lighting Normal Lighting Replace the outdoor electronic control P.C. board. Confirm LED1 indication lamp on the outdoor electronic control P.C. board. Blink 9 times Replace the power board. Turn OFF power supply before removing P.C. board. 137 13-7. TEST POINT DIAGRAM AND VOLTAGE 1. Inverter P.C. board MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA 8V DC Back side of unit 230V AC Input 325V DC FUSE(F801) T3.15AL250V 5V DC 12V DC FUSE(F901) T3.15AL250V JK,JGO To interface P.C. board (CN937) Output to drive compressor (LDW, LDV, LDU) LEV A (CN791) 5V GND 5V DC pulse wave (CN931) Fin temperature thermistor/RT64 (CN662) Ambient temperature thermistor /RT65 (CN663) Outdoor heat exchanger temperature thermistor /RT68 (CN661) To fan motor Defrost thermistor (RT61) Ambient temperature thermistor (RT65) Outdoor heat exchanger temperature thermistor (RT68) 180 90 160 80 140 70 700 120 60 600 100 50 500 80 40 400 60 30 300 40 20 200 20 10 100 0 0 10 20 30 40 50 60 70 80 Output to drive outdoor fan motor (CN932) ( Discharge temperature thermistor/RT62 (CN661) 100 Defrost thermistor/RT61 (CN661) Fin temperature thermistor (RT64) GND 12V Primary current R.V. coil (CN933) X64 Zero cross 200 To display P.C. board (CN935) Front side of unit ( LEV B (CN792) 0 -20 Discharge temperature thermistor (RT62) 0 -10 0 10 138 20 30 40 0 10 20 30 40 50 60 70 80 90 100 110 120 ( CN791 ( ( ( ( ( CN602 Serial signal Room B 12~24V DC Bus-bar voltage CN801 325~370 V DC Input F801 FUSE T3.15AL250V ( LED 3 (–) (+) ( ( ( 12V DC (–) pulse wave LEV Room (+) A CN792 12V DC (–) pulse wave LEV Room (+) B CN793 12V DC (–) pulse wave LEV Room (+) C CN794 12V DC (–) pulse wave (+) LEV Room D CN681 MXZ-4A80VA High pressure switch ( ( ( ( LEV E LED 2 CN795 12V DC pulse wave ( CN604 Serial signal Room D 12~24V DC LED 1 40 30 20 10 0 CN781 (+) 12V R.V. coil (–) DC Rush current relay (–) GND (power board) ( ( ( ( ( CN931 GND 5V 5V DC pulse wave CN932 20-90V AC ( Resistance (kΩ) 60 400 Temperature (°C) To fan motor ( Gas pipe A thermistor (RT6A) Gas pipe B thermistor (RT6B) Gas pipe C thermistor (RT6C) CN662 Gas pipe D thermistor (RT6D) ( 80 600 -10 Outdoor heat exchanger temperature thermistor (RT68) ( Temperature (°C) 70 500 Resistance (kΩ) 90 700 0 -20 15V 15V CN702 (–) Signal reception (From power board) GND 5V DC pulse wave (+) CN701 Signal transmission (+) (To power board) (–) 5V DC pulse wave CN663 Ambient temperature thermistor (RT65) 20 Discharge temperature thermistor (RT62) ( Defrost thermistor (RT61) ( 100 139 10 100 110 120 90 80 70 60 50 40 30 20 10 0 0 ( ( ( ( 30 CN661 40 200 100 Discharge temperature thermistor (RT62) 50 300 (Except MXZ-3A54VA- E4 , E5 , E6 , E7 and MXZ-4A71VA- E4 , E5 , E6 , E7 .) E1 Outdoor heat exchanger temperature thermistor (RT68) MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA - Defrost thermistor (RT61) Ambient temperature thermistor (RT65) Gas pipe temperature thermistor (RT6A, 6B, 6C, 6D) 2. Outdoor electronic control P.C. board SW1 CN603 Serial signal Room C 12~24V DC CN601 230V AC Input Serial signal Room A 12~24V DC MXZ-4A80VA - MXZ-5A100VA E2 Defrost thermistor (RT61) Ambient temperature thermistor (RT65) Outdoor heat exchanger temperature thermistor (RT68) Discharge temperature thermistor (RT62) 100 700 Resistance (kΩ) 90 Resistance (kΩ) 600 500 400 300 70 60 50 40 200 30 100 0 80 20 0 10 20 30 40 50 60 70 80 90 100 110 120 10 0 -20 -10 0 10 20 30 40 Temperature (°C) To fan motor CN932 20-90V AC ( ( ( CN781 R.V. coil (–) (+) Rush current relay (–) GND GND 15V DC CN702 Signal reception (From power board) 5V DC pulse wave CN701 Signal transmission (To power board) 5V DC pulse wave CN663 Ambient temperature thermistor (RT65) CN661 Outdoor heat exchanger temperature thermistor (RT68) Discharge temperature thermistor (RT62) Defrost temperature thermistor (RT61) GND 5V DC 5V DC pulse wave Temperature (°C) LED 1 LED 2 LED 3 CN641 Serial signal Room E (MXZ-5A100VA) 12~24V DC F931 FUSE T3.15AL250V CN631 Serial signal Room D 12~24V DC CN621 Serial signal Room C 12~24V DC SW1 SW2 SW871 CN611 Serial signal Room B 12~24V DC CN601 230V AC Bus-bar voltage CN801 325~370 V DC Input Input Serial signal Room A 12~24V DC F801 FUSE T3.15AL250V {( – + CN796 LEV F 12V DC pulse wave ( CN795 LEV Room E (MXZ-5A100VA) CN794 LEV Room D CN793 LEV Room C CN792 LEV Room B CN681 High pressure switch 140 CN791 LEV Room A 3. Noise filter P.C. board MXZ-3A54VA - E1 , E2 , E3 , E4 MXZ-4A71VA - E1 , E2 , E3 , E4 MXZ-4A80VA - E1 CN901 To electronic CN902 CN903 control To power To power P.C. board board board { { 230V AC Input { { CN912 R.V. coil 230V AC 230V AC Output F64 FUSE T2AL250V NR64 VARISTOR MXZ-3A54VA - E5 , E6 , E7 CN901 To electronic control P.C. board MXZ-4A71VA CN903 To power board { { CN912 R.V. coil 230V AC F911 FUSE T1AL250V E5 , E6 , E7 CN902 To power board { CN61 230V AC Output 230V AC Output F65 FUSE T6.3AL250V 230V AC Input F64 FUSE T2AL250V 141 CN61 230V AC Output MXZ-4A80VA - E2 MXZ-5A100VA CN912 R.V. coil 230V AC { { CN901 To electronic control CN902 CN903 P.C. board To power To power board board { CN61 230V AC Output 230V AC Output F65 FUSE T6.3AL250V F64 FUSE T2AL250V 230V AC Input 4. Power P.C. board MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA F61 (FUSE) T20AL250V Back side of unit Front side of unit 230V AC Input 230V AC Output R.V.coil (CN912) 230V AC 12V R.V.coil GND Zero cross X64 Primary current ( FUSE (F64) T3.15AL250V To inverter P.C.board (CN934) 142 5. Outdoor Power board Fin temperature thermistor (RT64) 200 MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA Resistance (kΩ) 180 160 140 120 100 80 60 40 20 0 0 10 20 30 40 50 60 70 80 Temperature (°C) 325-370V DC Output (Red) (+) 1 Connect to the compressor Voltage among phases: 5V to 180V (–) 3 Connect to the earth (White) CN2 Connect to the controller board (+)1-5(–): Signal transmission (To electronic control P.C. board) 5V DC pulse wave (+)2-5(–): Zero cross signal 3-4 : Not used (+)6-5(–): 15V (+)7-5(–): 15V CN3 Fin temperature thermistor RT64 reception (From ) Signal electronic control P.C. board) 5V DC pulse wave CN5 Primary current detection (Connect to the noise filter) Connect to the compressor Voltage among phases: 5V to 180V Connect to the earth CN2 Connect to the controller board (+)1-5(–): Signal transmission (To electronic control P.C. board) 5V DC pulse wave (+)2-5(–): Zero cross signal 3-4 : Not used (+)6-5(–): 15V (+)7-5(–): 15V 325-370V DC Output (Red) (+) 1 (–) 3 (White) CN3 Fin temperature thermistor RT64 reception (From ) Signal electronic control P.C. board) 5V DC pulse wave CN5 Primary current detection (Connect to the noise filter) 143 6. Display P.C. board MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA ) To inverter P.C. board (CN936) 5V SW1 GND LED1 LED2 7. Interface P.C. board MXZ-2A40VA MXZ-2A52VA To inverter P.C. board (CN938) ) MXZ-2A30VA 5V GND Serial signal room A Serial signal room B 230V AC 144 14 DISASSEMBLY INSTRUCTIONS <"Terminal with locking mechanism" Detaching points> The terminal which has the locking mechanism can be detached as shown below. There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism. The terminal without locking mechanism can be detached by pulling it out. Check the shape of the terminal before detaching. (1) Slide the sleeve and check if there is a locking lever or not. (2) The terminal with this connector has the locking mechanism. Sleeve Locking lever Slide the sleeve. Pull the terminal while pushing the locking lever. Hold the sleeve, and pull out the terminal slowly. Connector 14-1. MXZ-2A30VA MXZ-2A40VA MXZ-2A52VA PHOTOS OPERATING PROCEDURE Photo 1 1. Removing the cabinet (1) (2) (3) (4) (5) (6) (7) (8) (9) Remove the screw fixing the service panel. Pull down the service panel and remove it. Disconnect the power supply and indoor/outdoor connecting wire. Remove the screws fixing the top panel. Remove the top panel. Remove the screws fixing the cabinet. Remove the cabinet. Remove the screws fixing the back panel. Remove the back panel. Screws of the top panel Screw of the cabinet Screws of the top panel Back Screw panel of the service panel Direction to remove Hooks Screws of the cabinet 145 Service panel OPERATING PROCEDURE PHOTOS 2. Removing the inverter assembly, inverter P.C. board and power P.C. board (1) Remove the top panel, cabinet and service panel (Refer to 1). (2) Disconnect the power supply and indoor/outdoor connecting wire and remove the back panel (Refer to 1). (3) Disconnect the earth wires, the lead wire to the reactor and the following connectors; <Power P.C. board> CN912 (R.V coil) <Inverter P.C. board> CN931, CN932 (Fan motor) CN661 (Defrost thermistor, discharge temperature thermistor and outdoor heat exchanger temperature thermistor) CN663 (Ambient temperature thermistor) CN791, CN792 (LEV A, LEV B) (4) Remove the compressor connector (CN61). (5) Remove the screws fixing the relay panel. (6) Remove the inverter assembly. (7) Disconnect all connectors and lead wires on the inverter P.C. board. (8) Remove the inverter P.C. board from the inverter assembly. (9) Remove the screw fixing the power P.C. board. (10) Disconnect all connectors and lead wires on the power P.C. board. (11) Remove the power P.C. board from the inverter assembly. Photo 2 Screws of the relay panel Inverter assembly Screws of the earth wires Photo 3 Heat sink Inverter P.C. board Power P.C. board 3. Removing R.V. coil (1) Remove the top panel, cabinet and service panel (Refer to 1). (2) Disconnect the power supply and indoor/outdoor connecting wire and remove the back panel (Refer to 1). (3) Remove the inverter assembly (Refer to 2). (4) Remove the R.V. coil. Compressor connector (CN61) 4. Removing the discharge temperature thermistor, defrost thermistor and outdoor heat exchanger temperature thermistor Photo 4 Screw of the power P.C. board R.V. coil (1) Remove the top panel, cabinet and service panel (Refer to 1). (2) Disconnect the power supply and indoor/outdoor connecting wire and remove the back panel (Refer to 1). (3) Remove the inverter assembly (Refer to 2). (4) Pull out the discharge temperature thermistor from its holder. (5) Pull out the defrost thermistor from its holder (Photo 5). (6) Pull out the outdoor heat exchanger temperature thermistor from its holder (Photo 5). Discharge temperature thermistor 146 OPERATING PROCEDURE PHOTOS 5. Removing outdoor fan motor Photo 5 (1) Remove the top panel, cabinet and service panel (Refer to 1). (2) Disconnect the power supply and indoor/outdoor connecting wire. (3) Disconnect the connectors for outdoor fan motor. (4) Remove the propeller nut. (5) Remove the propeller. (6) Remove the screws fixing the fan motor (Photo 6). (7) Remove the fan motor. Outdoor heat exchanger temperature thermistor 6. Removing the compressor and 4-way valve (1) Remove the top panel, cabinet and service panel (Refer to 1). (2) Disconnect the power supply and indoor/outdoor connecting wire and remove the back panel (Refer to 1). (3) Remove the inverter assembly (Refer to 2). (4) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). (5) Detach the welded part of the suction and the discharge pipe connected with compressor. (6) Remove the nuts of compressor legs. (7) Remove the compressor. (8) Detach the welded part of pipes connected with 4-way valve (Photo 7). Defrost thermistor Photo 6 Screws of the outdoor fan motor Propeller Propeller nut Photo 7 Welded parts of 4-way valve 147 14-2. MXZ-3A54VA - E1 , E2 , E3 , E4 MXZ-4A71VA - E1 , E2 , E3 OPERATING PROCEDURE , E4 PHOTOS 1. Removing the compressor Photo 1 Screws of the top panel (1) Remove the screws of the top panel, and remove the top panel. (2) Remove the screws of the service panel, and remove the service panel. (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). (4) Remove the screws of the cabinet, and remove the cabinet. (5) Remove the screws of the back panel, and remove the back panel (Photo 3). (6) Disconnect the compressor lead wire from terminal of the compressor (U, V, W). (7) Disconnect the outdoor electronic control P.C. board connectors: CN661, CN662 (MXZ-3A54/4A71VA- E1 , E2 , E3 ), CN663, CN791, CN792, CN793, CN794 (MXZ-4A71VA- E1 , E2 , E3 , E4 ), CN795, CN931, CN932 Disconnect the noise filter P.C. board connector: CN912 (8) Remove the screws of the electrical parts, and remove the electrical parts (Photo 4). (9) Remove the propeller. (10) Remove the screws of the separator, and remove the separator (Photo 6). (11) Remove the sound proof felt (Photo 6). (12) Detach the welded parts of the compressor suction and discharge pipes (Photo 5). (13) Remove the compressor nuts and remove the compressor. Screws of the cabinet Screws of service panel Screw of the cabinet Screws of the cabinet Photo 2 Screws of the top panel Screws of the cabinet 148 Screws of the cabinet PHOTOS OPERATING PROCEDURE Photo 3 Screw of the rear guard Screw of the back panel Photo 5 R.V. coil 4 way valve Screws of the back panel LEV coil E Expansion valve E Suction pipe welded part Screws of the back panel Discharge pipe welded part Screw of the back panel Photo 4 Compressor nuts Screws of the electrical parts Photo 6 2. Removing the fan motor (1) Remove the top panel, the service panel, and the cabinet (Photo 1, 2). (2) Disconnect the connector CN931 and CN932 on the outdoor electronic control P.C. board. (3) Remove the propeller. (4) Remove the fan motor. Screws of the outdoor fan motor Propeller Sound proof felt Propeller nut Separator 149 OPERATING PROCEDURE PHOTOS 3. Removing the 4-way valve (1) Remove the top panel (Photo 1). (2) Remove the service panel, the cabinet, and the back panel (Photo 1, 2, 3). (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). Photo 7 4 way valve R.V. coil (4) Remove the electrical parts (Photo 4). (5) Detach the welded parts of 4-way valve and pipe (Photo 7). Welded parts 4. Removing the expansion valve (1) Remove the top panel (Photo 1). (2) Remove the service panel, the cabinet, and the back panel (Photo 1, 2, 3). (Gas recovery is not required if the unit is pumped down.) (3) Remove the electrical parts for removing LEV E (Photo 4, 5). (4) Remove the LEV coils. (5) Detach the welded parts of expansion valves and pipes. Photo 8 Expansion valves LEV coils 5. Removing the reactor (1) Remove the top panel (Photo 1). (2) Remove the service panel, cabinet, back panel, and the electrical parts (Photo 1, 2, 3, 4). (3) Disconnect the reactor lead wire from the terminal of the reactor. (4) Remove the screws of the reactor, and remove the reactor (Photo 9). Photo 9 Screws of the reactor 150 14-3. MXZ-3A54VA - E5 , E6 , E7 MXZ-4A71VA - E5 , E6 , E7 OPERATING PROCEDURE PHOTOS 1. Removing the compressor Photo 1 Screws of the top panel (1) Remove the screws of the top panel, and remove the top panel. (2) Remove the screws of the service panel, and remove the service panel. (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). (4) Remove the screws of the cabinet, and remove the cabinet. (5) Remove the screws of the back panel, and remove the back panel (Photo 3). (6) Disconnect the compressor lead wire from terminal of the compressor (U, V, W). (7) Disconnect the outdoor electronic control P.C. board connectors: CN661, CN663, CN791, CN792, CN793, CN794 (MXZ-4A71VA- E5 , E6 , E7 ), CN795, CN931, CN932 Disconnect the noise filter P.C. board connector: CN912 (8) Remove the screws of the electrical parts, and remove the electrical parts (Photo 4). (9) Remove the propeller. (10) Remove the screws of the separator, and remove the separator (Photo 6). (11) Remove the sound proof felt (Photo 6). (12) Detach the welded parts of the compressor suction and discharge pipes (Photo 5). (13) Remove the compressor nuts and remove the compressor. Screws of the cabinet Screws of service panel Screws of the cabinet Photo 2 Screws of the top panel 2. Removing the electronic control P.C. board (1) Remove the screws of the sub panel. (2) Remove the sub panel. (3) Disconnect all connectors and lead wires on the electronic control P.C. board. (4) Remove the electronic control P.C. board. 151 Screw of the cabinet Screws of the cabinet Screws of the cabinet Screws of the sub panel PHOTOS OPERATING PROCEDURE Photo 3 Screw of the rear guard Screw of the back panel Photo 5 R.V. coil 4 way valve Screws of the back panel LEV coil E Expansion valve E Suction pipe welded part Screws of the back panel Screw of the back panel Discharge pipe welded part Photo 4 Compressor nuts Screws of the electrical parts 3. Removing the fan motor (1) Remove the top panel, the service panel, and the cabinet (Photo 1, 2). (2) Disconnect the connector CN931 and CN932 on the outdoor electronic control P.C. board. (3) Remove the propeller. (4) Remove the fan motor. Photo 6 Screws of the outdoor fan motor Propeller nut Propeller 152 Separator Sound proof felt OPERATING PROCEDURE PHOTOS 4. Removing the 4-way valve (1) Remove the top panel (Photo 1). (2) Remove the service panel, the cabinet, and the back panel (Photo 1, 2, 3). (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). Photo 7 4 way valve (4) Remove the electrical parts (Photo 4). (5) Detach the welded parts of 4-way valve and pipe (Photo 7). R.V. coil Welded parts 5. Removing the expansion valve (1) Remove the top panel (Photo 1). (2) Remove the service panel, the cabinet, and the back panel (Photo 1, 2, 3). (Gas recovery is not required if the unit is pumped down.) (3) Remove the electrical parts for removing LEV E (Photo 4, 5). (4) Remove the LEV coils. (5) Detach the welded parts of expansion valves and pipes. Photo 8 Expansion valves LEV coils 6. Removing the reactor (1) Remove the top panel (Photo 1). (2) Remove the service panel, cabinet, back panel, and the electrical parts (Photo 1, 2, 3, 4). (3) Disconnect the reactor lead wire from the terminal of the reactor. (4) Remove the screws of the reactor, and remove the reactor (Photo 9). Photo 9 Screws of the reactor 153 14-4. MXZ-4A80VA - E1 OPERATING PROCEDURE PHOTOS 1. Removing the compressor Photo 1 (1) Remove the screws of the top panel, and remove the top panel. (2) Remove the screws of the service panel, and remove the service panel. (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). (4) Remove the screws of the front panel, and remove the front panel. (5) Disconnect the compressor lead wire from terminal of compressor (U, V, W). (6) Disconnect the outdoor electronic control P.C. board connectors: CN661, CN662 , CN663, CN681, CN791, CN792, CN793, CN794, CN795, CN931, CN932 Disconnect the noise filter P.C. board connector: CN912 (7) Remove the screws of the electrical parts, and remove the electrical parts. (8) Remove the propeller. (9) Remove the screws of the separator, and remove the separator. (10) Remove the sound proof felt. (11) Detach the welded parts of the compressor suction and discharge pipes (Photo 3). (12) Remove the compressor nuts and remove the compressor. Screws of the top panel Screws of service panel Screws of the front panel Photo 2 Screws of the electrical parts Electronic control P.C. board Photo 3 LEV coil E Expansion valve E Suction pipe welded part Discharge pipe welded part Terminal 154 PHOTOS OPERATING PROCEDURE Photo 4 2. Removing the fan motor (1) Remove the top panel, the service panel, and the front panel (Photo 1). (2) Disconnect the connector CN931 and CN932 on the outdoor electronic control P.C. board. (3) Remove the propeller. (4) Remove the fan motor. Screws of the outdoor fan motor Propeller Sound proof felt Propeller nut 3. Removing the 4-way valve (1) Remove the top panel (Photo 1). (2) Remove the service panel, rear panel, and pipe cover. (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). Separator Compressor nuts Photo 5 4 way valve (4) Remove the electrical parts (Photo 2). (5) Detach the welded parts of 4-way valve and pipe (Photo 5). R.V. coil Welded parts 4. Removing the expansion valve Photo 6 (1) Remove the top panel (Photo 1). (2) Remove the service panel (Photo 1). (Gas recovery is not required if the unit is pumped down.) (3) Remove the front panel for removing LEV E (Photo 1). (4) Remove the electrical parts for removing LEV E (Photo 2,3). (5) Remove the LEV coils. (6) Detach the welded parts of expansion valves and pipes. Expansion valves LEV coils 155 OPERATING PROCEDURE PHOTOS 5. Removing the reactor (1) Remove the top panel (Photo 1). (2) Disconnect the reactor lead wire. (3) Remove the screws of the reactor, and remove the reactor (Photo 7). Photo 7 Screws of the reactor 156 14-5. MXZ-4A80VA - E2 MXZ-5A100VA OPERATING PROCEDURE PHOTOS 1. Removing the compressor Photo 1 (1) Remove the screws of the top panel, and remove the top panel. (2) Remove the screws of the service panel, and remove the service panel. (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). (4) Remove the screws of the front panel, and remove the front panel. (5) Remove the screws of the rear panel, and remove the rear panel. (6) Disconnect the compressor lead wire from terminal of compressor (U, V, W). (7) Disconnect the outdoor electronic control P.C. board connectors: CN661, CN663, CN681, CN791, CN792, CN793, CN794, CN795 (MXZ-5A100VA), CN796, CN931, CN932 Disconnect the noise filter P.C. board connector: CN912 (8) Remove the screws of the electrical parts, and remove the electrical parts. (9) Remove the propeller. (10) Remove the screws of the separator, and remove the separator. (11) Remove the sound proof felt. (12) Detach the welded parts of the compressor suction and discharge pipes (Photo 4). (13) Remove the compressor nuts and remove the compressor. Screws of the top panel Screws of the service panel Screws of the front panel Photo 2 Screws of the top panel Screws of the side panel Photo 3 Screws of the service panel Screws of the electrical parts Screws of the rear panel Photo 4 Suction pipe welded part Discharge pipe welded part Compressor nuts (3 places) 157 PHOTOS OPERATING PROCEDURE Photo 5 2. Removing the fan motor Screws of the outdoor fan motor (1) Remove the top panel, the service panel, and the front panel (Photo 1). (2) Disconnect the connector CN931 and CN932 on the outdoor electronic control P.C. board. (3) Remove the propeller. (4) Remove the fan motor. Propeller Propeller nut Sound proof felt Separator 3. Removing the 4-way valve (1) Remove the top panel (Photo 1). (2) Remove the service panel, rear panel, and pipe cover. (3) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa). Photo 6 4 way valve R.V. coil (4) Remove the electrical parts (Photo 3). (5) Detach the welded parts of 4-way valve and pipe. Welded parts 4. Removing the expansion valve Photo 7 (1) Remove the top panel (Photo 1,2). (2) Remove the service panel (Photo 1). (Gas recovery is not required if the unit is pumped down.) (3) Remove the font panel for removing LEV F (Photo 1). (4) Remove the electrical parts for removing LEV F (Photo 3). (5) Remove the LEV coils. (6) Detach the welded parts of expansion valves and pipes. LEV coil F Expansion valve F LEV coils Expansion valves 158 OPERATING PROCEDURE PHOTOS 5. Removing the reactor (1) Remove the top panel (Photo 1). (2) Disconnect the reactor lead wire. (3) Remove the screws of the reactor, and remove the reactor. Photo 8 Screws of the reactor 159 15 PARTS LIST (non-RoHS compliant) MXZ-2A40VA - E1 MXZ-2A52VA - E1 15-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 17 10 14 16 15 18 19 13 1 11 12 3 4 2 160 5 6 7 8 9 PARTS LIST (non-RoHS compliant) MXZ-2A40VA - E1 MXZ-2A52VA - E1 15-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. Symbol No. Part No. Part Name Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 20 E02 21 E02 22 E02 927 927 927 A45 A47 065 927 927 A47 A47 735 A48 A47 929 929 929 927 A47 A47 339 838 735 A47 232 521 501 290 900 506 661 662 245 233 640 493 961 523 293 515 297 630 301 936 936 640 493 CABINET GRILLE PROPELLER BASE COMPRESSOR COMPRESSOR RUBBER SET STOP VALVE (GAS) STOP VALVE (LIQUID) SERVICE PANEL BACK PANEL EXPANSION VALVE EXPANSION VALVE COIL 4-WAY VALVE CONDENSER NET SEPARATOR MOTOR SUPPORT TOP PANEL OUTDOOR HEAT EXCHANGER OUTDOOR FAN MOTOR CAPILLARY TUBE CAPILLARY TUBE EXPANSION VALVE EXPANSION VALVE COIL Q'ty/unit in Wiring MC LEV B MF LEV A 161 MXZ-2A40VA1 1 1 1 1 3 2 2 1 1 1 1 1 1 1 1 1 1 1 4 2 1 1 E1 MXZ-2A52VA1 1 1 1 1 3 2 2 1 1 1 1 1 1 1 1 1 1 1 4 2 1 1 Remarks E1 SNB130FKCH 3RUBBERS/SET 9.52 6.35 ROOM B RC0J503.0 1.4 600 3.0 2.0 200 ROOM A PARTS LIST (non-RoHS compliant) MXZ-2A40VA - E1 MXZ-2A52VA - E1 15-2. OUTDOOR UNIT ELECTRICAL PARTS 12 13 11 10 9 8 1 2 3 4 5 6 7 Part numbers that are circled are not shown in the illustration. No. Part No. 1 2 3 4 5 6 7 8 9 10 11 12 838 A47 A47 A47 A47 A47 A47 A47 735 A47 935 935 A47 A48 127 661 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 13 E02 14 E02 15 E02 337 440 454 490 308 309 329 337 382 374 374 374 451 451 382 385 Part Name Q'ty/unit Symbol in Wiring Diagram MXZ-2A40VA- E1 MXZ-2A52VA- REACTOR L64 POWER P.C. BOARD INTERFACE P.C. BOARD R.V. COIL 21S4 THERMISTOR SET RT61,62,68 AMBIENT TEMPERATURE THERMISTOR RT65 DISPLAY P.C. BOARD L65 REACTOR F61 FUSE TERMINAL BLOCK TB1 TERMINAL BLOCK TB3 TB2 TERMINAL BLOCK INVERTER P.C. BOARD INVERTER P.C. BOARD F64,801,901 FUSE NR61,62,63,64 VARISTOR 162 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E1 Remarks 10A 23mH DEFROST, DISCHARGE OUTDOOR HEAT EXCHANGER 2A 25mH T20AL250V Power supply Indoor unit connecting Indoor unit connecting Including heat sink and RT64 Including heat sink and RT64 T3.15AL250V PARTS LIST (non-RoHS compliant) MXZ-2A40VA - E1 MXZ-2A52VA 15-3. DRAIN SOCKET E1 Outdoor unit 42 drain hole 1 Soft vinyl chloride hose of 25 mm inside diameter No. Parts No. Parts Name Q'ty/unit Symbol in Wiring MXZ-2A40VA- E1 MXZ-2A52VADiagram 1 E02 838 704 DRAIN SOCKET 1 163 1 E1 Remarks PARTS LIST (non-RoHS compliant) MXZ-3A54VA - E1 , E2 MXZ-4A71VA - E1 , E2 15-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 23 21 22 24 20 19 18 17 16 1 15 12 2 11 3 4 5 6 7 8 164 9 10 13 14 PARTS LIST (non-RoHS compliant) MXZ-3A54VA - E1 , E2 MXZ-4A71VA - E1 , E2 15-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Parts No. E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 E02 939 817 939 939 065 851 939 851 938 851 939 851 938 939 939 979 939 939 939 939 939 938 853 851 891 819 939 939 939 938 939 938 938 232 009 521 900 506 640 494 640 494 640 493 640 493 290 666 666 667 233 245 661 662 959 640 493 961 297 523 630 515 937 936 936 299 Parts Name CABINET HANDLE GRILLE COMPRESSOR COMPRESSOR RUBBER SET EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL BASE UNION(GAS) UNION(GAS) UNION(LIQUID) BACK PANEL SERVICE PANEL BALL VALVE (GAS) 5/8 BALL VALVE (LIQUID) 3/8 POWER RECEIVER EXPANSION VALVE LEV COIL 4-WAY VALVE TOP PANEL REAR GUARD OUTDOOR HEAT EXCHANGER MOTOR SUPPORT CAPILLARY TUBE CAPILLARY TUBE CAPILLARY TUBE OIL SEPARATOR Q'ty/unit Symbol MXZ-4A71VAMXZ-3A54VAin Wiring Diagram E1 E2 E1 E2 MC 1 1 1 1 3 1 1 1 1 3 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 8 3 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 8 3 1 1 LEV D LEV C LEV B LEV A LEV E 165 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 1 4 1 1 1 1 1 1 1 1 1 1 1 1 8 4 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 1 4 1 1 1 1 1 1 1 1 1 1 1 1 8 4 1 1 Remarks SNB130FLDH1 3RUBBERS SET D room D room C room C room B room B room A room A room 9.52 12.7 6.35 15.88 9.52 E 3.6 4.0 2.5 2.4 500 2.8 100 0.6 1000 PARTS LIST (non-RoHS compliant) MXZ-3A54VA - E1 , E2 MXZ-4A71VA - E1 , E2 15-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS 12 11 10 9 8 1 3 2 4 5 15-6. ACCESSORY 6 17 16 166 7 PARTS LIST (non-RoHS compliant) MXZ-3A54VA - E1 , E2 MXZ-4A71VA - E1 , E2 15-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS Part numbers that are circled are not shown in the illustration. No. Parts No. 1 E02 851 501 2 E02 938 301 3 E02 939 440 E02 938 450 4 E02 939 450 5 E02 938 444 6 E02 927 374 7 E02 823 375 E02 938 307 8 E02 939 307 9 E02 939 490 10 E02 938 308 11 E02 938 309 12 E02 938 337 13 E02 127 382 14 E02 737 382 15 E02 735 385 Parts Name PROPELLER OUTDOOR FAN MOTOR POWER BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD NOISE FILTER P.C. BOARD TERMINAL BLOCK TERMINAL BLOCK GAS PIPE TEMPERATURE THERMISTOR SET GAS PIPE TEMPERATURE THERMISTOR SET R.V. COIL THERMISTOR SET AMBIENT TEMPERATURE THERMISTOR REACTOR FUSE FUSE FUSE&VARISTOR SET Symbol in Wiring Diagram MF TB2~5 TB1 RT6A,B,C RT6A,B,C,D 21S4 RT61,62,68 RT65 L F801 F911 F64,NR64 Q'ty/unit MXZ-3A54VA- MXZ-4A71VA- E1 E2 E1 E2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 3 1 1 1 1 4 1 1 1 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Remarks RC0J60Including heat sink and RT64 Indoor unit connecting Power supply DEFROST, DISCHARGE OUTDOOR HEAT EXCHANGER 20A 600μH T3.15AL250V T1AL250V T2AL250V 15-6. ACCESSORY No. Parts No. Parts Name Q'ty/unit Symbol MXZ-4A71VAin Wiring MXZ-3A54VADiagram E1 E2 E1 E2 16 E02 817 704 DRAIN SOCKET 17 E02 444 705 DRAIN CAP 1 2 167 1 2 1 2 1 2 Remarks PARTS LIST (non-RoHS compliant) MXZ-4A80VA - E1 15-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 25 24 23 22 21 19 18 20 2 14 15 17 16 1 2 5 13 6 11 7 8 9 10 3 4 168 12 PARTS LIST (non-RoHS compliant) MXZ-4A80VA - E1 15-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. No. Parts No. 1 2 3 4 5 6 M21 TK0 232 M21 TK0 027 M21 TK5 010 M21 TK0 245 T92 500 801 T2W TK0 505 R01 E39 401 T2W TK0 654 R01 E39 401 T2W TK0 653 R01 E39 401 T2W TK0 652 R01 E39 401 T2W TK0 651 M21 TK0 290 M21 42E 644 T2W TK0 247 M21 TK5 667 M21 TK0 667 M21 TK0 248 T2W TK0 959 M21 G0H 642 M21 NT1 646 T2W WW8 401 T2W TK0 651 M21 TK0 297 T2W E40 523 M21 YH1 630 M21 TK0 249 M21 SJ4 937 M21 TK0 936 T2W E59 936 T2W YH1 656 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Parts Name FRONT PANEL HANDLE ASSEMBLY GRILLE SERVICE PANEL COMPRESSOR COMPRESSOR RUBBER SET EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL BASE ASSEMBLY UNION PIPE COVER BALL VALVE (LIQUID) 3/8 BALL VALVE (GAS) 5/8 REAR PANEL POWER RECEIVER 4-WAY VALVE HIGH PRESSURE SWITCH EXPANSION VALVE LEV COIL TOP PANEL REAR GUARD OUTDOOR HEAT EXCHANGER SIDE PANEL CAPILLARY TUBE CAPILLARY TUBE CAPILLARY TUBE OIL SEPARATOR Symbol in Wiring Diagram MC LEV D LEV C LEV B LEV A HPS LEV E 169 Q'ty/unit MXZ-4A80VA1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 Remarks E1 TNB220FMCH 3RUBBERS SET D room D room C room C room B room B room A room A room 12.7, 9.52, 6.35 SET 9.52 15.88 4.8 MPa (48.9 kg/cm2) E 4.0 4.0 2.5 2.4 400 2.8 90 0.6 1000 PARTS LIST (non-RoHS compliant) MXZ-4A80VA - E1 15-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS 12 11 10 9 8 7 1 15-9. ACCESSORY 2 3 4 5 16 170 6 PARTS LIST (non-RoHS compliant) MXZ-4A80VA - E1 15-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS Part numbers that are circled are not shown in the illustration. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Parts No. M21 M21 T2W T2W M21 T2W T2W T2W T2W T2W M21 M21 T2W T2W T2W TK0 TK0 YH1 YH1 TK0 YH1 YH1 E64 E70 TK0 G0H 90V YH1 YH1 E88 501 301 440 451 337 424 376 376 307 398 308 309 381 382 313 Parts Name Symbol in Wiring Diagram PROPELLER MF OUTDOOR FAN MOTOR POWER BOARD ELECTRONIC CONTROL P.C. BOARD L REACTOR NOISE FILTER P.C. BOARD TERMINAL BLOCK TB2~5 TERMINAL BLOCK TB1 GAS PIPE TEMPERATURE THERMISTOR RT6A,B,C,D R.V. COIL 21S4 THERMISTOR SET RT61,62,68 AMBIENT TEMPERATURE THERMISTOR RT65 FUSE F801 FUSE F911 FUSE&VARISTOR SET F64,NR64 Q'ty/unit MXZ-4A80VA- E1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 Remarks PM8H60Including heat sink and RT64 20A 600μH Indoor unit connecting Power supply DEFROST, DISCHARGE, OUTDOOR HEAT EXCHANGER T3.15AL250V T1AL250V T2AL250V 15-9. ACCESSORY No. Parts No. Parts Name Symbol in Wiring Diagram 16 T2W E59 704 DRAIN SOCKET ASSEMBLY Q'ty/unit MXZ-4A80VA1 171 E1 Remarks DRAIN SOCKET DRAIN CAP 2 1 16 RoHS PARTS LIST (RoHS compliant) MXZ-2A30VA - E1 , E2 MXZ-2A40VA - E1 , E2 MXZ-2A52VA - E1 , E2 16-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 17 10 14 16 15 18 19 13 1 11 12 3 4 2 172 5 6 7 8 9 RoHS PARTS LIST (RoHS compliant) MXZ-2A30VA - E1 , E2 MXZ-2A40VA - E1 , E2 MXZ-2A52VA - E1 , E2 16-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 RoHS Part numbers that are circled are not shown in the illustration. G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Symbol Part No. E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 927 927 927 A45 A47 B70 C04 B93 065 927 927 A47 A47 735 A48 A47 927 929 838 929 927 929 927 927 A47 B70 A47 339 838 735 A47 232 521 501 290 900 900 900 900 506 661 662 245 233 640 493 961 961 523 523 293 293 515 515 297 630 630 301 936 936 640 493 Part Name CABINET GRILLE PROPELLER BASE COMPRESSOR COMPRESSOR COMPRESSOR COMPRESSOR COMPRESSOR RUBBER SET STOP VALVE (GAS) STOP VALVE (LIQUID) SERVICE PANEL BACK PANEL EXPANSION VALVE EXPANSION VALVE COIL 4-WAY VALVE 4-WAY VALVE CONDENSER NET CONDENSER NET SEPARATOR SEPARATOR MOTOR SUPPORT MOTOR SUPPORT TOP PANEL OUTDOOR HEAT EXCHANGER OUTDOOR HEAT EXCHANGER OUTDOOR FAN MOTOR CAPILLARY TUBE CAPILLARY TUBE EXPANSION VALVE EXPANSION VALVE COIL Q'ty/unit in Wiring MXZ-2A30VA- MXZ-2A40VA- MXZ-2A52VADiagram E1 E1 E2 E1 E2 E2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MC 1 1 MC 1 MC 1 MC 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEV B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MF 4 4 4 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 LEV A 173 Remarks SNB130FKCH KNB092FEDH SNB130FKMH KNB073FGDH 3RUBBERS/SET 9.52 6.35 ROOM B RC0J503.0 1.4 600 3.0 2.0 200 ROOM A RoHS PARTS LIST (RoHS compliant) MXZ-2A30VA - E1 , E2 MXZ-2A40VA - E1 , E2 MXZ-2A52VA 16-2. OUTDOOR UNIT ELECTRICAL PARTS 13 12 E1 , E2 11 10 9 8 1 2 3 4 5 6 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 RoHS Part numbers that are circled are not shown in the illustration. G G G G G G G G G G G G G G G 13 G G G 14 G 15 G Part No. E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 838 A47 A47 A47 A47 A47 A47 A47 735 A47 935 935 A47 A48 B70 B71 C04 C58 127 661 337 440 454 490 308 309 329 337 382 374 374 374 451 451 451 451 451 451 382 385 Part Name Q'ty/unit Symbol in Wiring MXZ-2A30VA- MXZ-2A40VA- MXZ-2A52VADiagram E1 E1 E2 E1 E2 E2 REACTOR L64 POWER P.C. BOARD INTERFACE P.C. BOARD R.V. COIL 21S4 THERMISTOR SET RT61,62,68 AMBIENT TEMPERATURE THERMISTOR RT65 DISPLAY P.C. BOARD REACTOR L65 FUSE F61 TERMINAL BLOCK TB1 TERMINAL BLOCK TB3 TERMINAL BLOCK TB2 INVERTER P.C. BOARD INVERTER P.C. BOARD INVERTER P.C. BOARD INVERTER P.C. BOARD INVERTER P.C. BOARD INVERTER P.C. BOARD FUSE F64,801,901 VARISTOR NR61,62,63,64 174 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Remarks 10A 23mH DEFROST, DISCHARGE OUTDOOR HEAT EXCHANGER 2A 25mH T20AL250V Power supply Indoor unit connecting Indoor unit connecting Including heat sink and RT64 Including heat sink and RT64 Including heat sink and RT64 Including heat sink and RT64 Including heat sink and RT64 Including heat sink and RT64 T3.15AL250V RoHS PARTS LIST (RoHS compliant) MXZ-2A30VA - E1 , E2 MXZ-2A40VA 16-3. DRAIN SOCKET E1 , E2 MXZ-2A52VA - E1 , E2 Outdoor unit 42 drain hole 1 No. RoHS Soft vinyl chloride hose of 25 mm inside diameter Parts No. Parts Name Q'ty/unit Symbol MXZ-2A30VAMXZ-2A40VAMXZ-2A52VAin Wiring Diagram E1 E1 E2 E1 E2 E2 1 G E12 838 704 DRAIN SOCKET 1 175 1 1 1 1 1 Remarks RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E1 , E2 , E3 , E4 MXZ-4A71VA - E1 , E2 , E3 , E4 16-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 23 21 22 24 20 19 18 17 16 1 15 12 2 11 3 4 5 6 7 8 176 9 10 13 14 RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E1 , E2 , E3 , E4 MXZ-4A71VA - E1 , E2 , E3 , E4 16-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS No. RoHS Part numbers that are circled are not shown in the illustration. Parts No. 1 G E12 939 2 G E12 817 3 G E12 939 G E12 939 4 G E12 C06 G E12 C18 5 G E12 065 G E12 851 6 G E12 939 G E12 851 7 G E12 938 G E12 851 8 G E12 939 G E12 851 9 G E12 938 10 G E12 939 G E12 C06 G E12 C18 11 G E12 C07 G E12 C19 G E12 C06 12 G E12 C18 13 G E12 939 14 G E12 939 15 G E12 C06 16 G E12 C06 G E12 938 17 G E12 C18 18 G E12 853 19 G E12 819 G E12 891 20 G E12 C18 21 G E12 819 22 G E12 939 23 G E12 939 24 G E12 939 25 G E12 938 26 G E12 939 27 G E12 938 28 G E12 938 232 009 521 900 900 900 506 640 494 640 494 640 493 640 493 290 666 666 666 666 667 667 233 245 661 662 959 959 640 493 961 961 297 523 630 515 937 936 936 299 Parts Name CABINET HANDLE GRILLE COMPRESSOR COMPRESSOR COMPRESSOR COMPRESSOR RUBBER SET EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL BASE UNION(GAS) UNION(GAS) UNION(GAS) UNION(GAS) UNION(LIQUID) UNION(LIQUID) BACK PANEL SERVICE PANEL BALL VALVE (GAS) 5/8 BALL VALVE (LIQUID) 3/8 POWER RECEIVER POWER RECEIVER EXPANSION VALVE LEV COIL 4-WAY VALVE 4-WAY VALVE TOP PANEL REAR GUARD OUTDOOR HEAT EXCHANGER MOTOR SUPPORT CAPILLARY TUBE CAPILLARY TUBE CAPILLARY TUBE OIL SEPARATOR Symbol in Wiring Diagram MC MC MC Q'ty/unit MXZ-3A54VA- MXZ-4A71VA- E1 E2 E3 E4 E1 E2 E3 E4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 3 1 1 3 LEV D LEV C LEV B LEV A 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 3 3 1 3 1 1 1 1 1 1 1 1 1 Remarks SNB130FLDH1 SNB130FLEH1 SNB130FGBH1 3RUBBERS SET D room D room C room C room B room B room A room A room 9.52 9.52 12.7 12.7 6.35 6.35 3 1 1 1 4 4 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 4 1 1 1 1 1 1 8 4 1 1 1 1 1 1 8 4 1 1 1 LEV E 177 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 3 1 1 1 1 1 1 8 3 1 1 1 1 1 1 8 3 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 8 3 1 1 4 1 1 1 1 15.88 9.52 1 1 E 1 1 1 1 1 1 8 4 1 1 3.6 4.0 2.5 2.4 500 2.8 100 0.6 1000 RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E1 , E2 , E3 , E4 MXZ-4A71VA - E1 , E2 , E3 , E4 16-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS 12 11 10 9 8 1 3 2 4 5 16-6. ACCESSORY 6 17 16 178 7 RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E1 , E2 , E3 , E4 MXZ-4A71VA - E1 , E2 , E3 , E4 16-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS No. RoHS Part numbers that are circled are not shown in the illustration. Parts No. 1 G E12 2 G E12 G E12 3 G E12 G E12 G E12 G E12 4 G E12 G E12 G E12 5 G E12 6 G E12 7 G E12 G E12 8 G E12 G E12 9 G E12 10 G E12 11 G E12 12 G E12 13 G E12 14 G E12 15 G E12 851 938 939 C07 938 939 C06 C07 C18 C19 938 927 823 938 939 939 C18 938 938 938 127 737 735 501 301 440 440 450 450 450 450 450 450 444 374 375 307 307 490 490 308 309 337 382 382 385 Parts Name Symbol in Wiring Diagram PROPELLER MF OUTDOOR FAN MOTOR POWER BOARD POWER BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD NOISE FILTER P.C. BOARD TB2~5 TERMINAL BLOCK TB1 TERMINAL BLOCK GAS PIPE TEMPERATURE THERMISTOR SET RT6A,B,C GAS PIPE TEMPERATURE THERMISTOR SET RT6A,B,C,D 21S4 R.V. COIL 21S4 R.V. COIL RT61,62,68 THERMISTOR SET RT65 AMBIENT TEMPERATURE THERMISTOR L REACTOR F801 FUSE F911 FUSE F64,NR64 FUSE&VARISTOR SET Q'ty/unit MXZ-3A54VA- MXZ-4A71VA- Remarks E1 E2 E3 E4 E1 E2 E3 E4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RC0J60- 1 Including heat sink and RT64 1 Including heat sink and RT64 1 1 1 1 1 1 1 1 3 1 1 1 3 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 4 1 1 4 1 1 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 Indoor unit connecting 1 Power supply 1 1 1 1 1 1 1 DEFROST, DISCHARGE OUTDOOR HEAT EXCHANGER 20A 600μH T3.15AL250V T1AL250V T2AL250V No. RoHS 16-6. ACCESSORY Parts No. Parts Name Q'ty/unit Symbol MXZ-4A71VAin Wiring MXZ-3A54VADiagram E1 E2 E3 E4 E1 E2 E3 E4 16 G E12 817 704 DRAIN SOCKET 17 G E12 444 705 DRAIN CAP 1 2 179 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Remarks RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E5 , E6 , E7 MXZ-4A71VA - E5 , E6 , E7 16-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 23 22 20 21 19 18 17 1 16 13 2 3 12 4 5 6 7 8 9 180 10 11 14 15 RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E5 , E6 , E7 MXZ-4A71VA - E5 , E6 , E7 16-7. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 RoHS Part numbers that are circled are not shown in the illustration. G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Parts No. E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 E12 D36 817 939 D36 C18 F10 C34 851 939 851 938 851 939 851 938 939 D36 D37 D36 939 D36 D36 D36 D36 C18 819 939 939 939 938 939 938 C18 853 819 232 009 521 246 900 900 506 640 494 640 494 640 493 640 493 290 666 666 667 233 245 662 661 299 961 297 523 630 515 937 936 936 959 640 493 Parts Name CABINET HANDLE GRILLE SUB PANEL COMPRESSOR COMPRESSOR COMPRESSOR RUBBER SET EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL BASE UNION(GAS) UNION(GAS) UNION(LIQUID) BACK PANEL SERVICE PANEL STOP VALVE (LIQUID) 3/8 STOP VALVE (GAS) 5/8 OIL SEPARATOR 4-WAY VALVE TOP PANEL REAR GUARD OUTDOOR HEAT EXCHANGER MOTOR SUPPORT CAPILLARY TUBE CAPILLARY TUBE CAPILLARY TUBE POWER RECEIVER EXPANSION VALVE LEV COIL Symbol in Wiring Diagram MC MC Q'ty/unit MXZ-3A54VA- MXZ-4A71VA- E5 E6 E7 E5 E6 E7 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 3 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 8 3 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 8 3 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 8 3 1 1 1 1 LEV D LEV C LEV B LEV A LEV E 181 3 1 1 1 1 1 1 1 1 1 3 1 4 1 1 1 1 1 1 1 1 1 1 8 4 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 1 4 1 1 1 1 1 1 1 1 1 1 8 4 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 1 4 1 1 1 1 1 1 1 1 1 1 8 4 1 1 1 1 Remarks SNB130FGBH1 SNB130FGBH1T 3RUBBERS SET D room D room C room C room B room B room A room A room 9.52 12.7 6.35 9.52 15.88 3.6 4.0 2.5 E 2.4 500 2.8 100 0.6 1000 RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E5 , E6 , E7 MXZ-4A71VA - E5 , E6 , E7 16-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS 11 10 9 8 1 2 3 4 5 6 16 16-9. ACCESSORY 15 182 7 RoHS PARTS LIST (RoHS compliant) MXZ-3A54VA - E5 , E6 , E7 MXZ-4A71VA - E5 , E6 , E7 16-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS No. RoHS Part numbers that are circled are not shown in the illustration. Parts No. 1 G E12 851 2 G E12 938 3 G E12 C07 G E12 D36 G E12 D87 G E12 F10 4 G E12 D37 G E12 D88 G E12 F11 5 G E12 D36 6 G E12 C92 7 G E12 D69 8 G E12 C18 9 G E12 938 10 G E12 938 11 G E12 938 12 G E12 784 13 G E12 250 14 G E12 977 501 301 440 450 450 450 450 450 450 444 375 374 490 308 309 337 382 382 385 Parts Name Symbol in Wiring Diagram PROPELLER MF OUTDOOR FAN MOTOR POWER BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD NOISE FILTER P.C. BOARD TB2~5 TERMINAL BLOCK TB1 TERMINAL BLOCK 21S4 R.V. COIL RT61,62,68 THERMISTOR SET RT65 AMBIENT TEMPERATURE THERMISTOR L REACTOR F801 FUSE F65 FUSE F64,NR64 FUSE&VARISTOR SET Q'ty/unit MXZ-3A54VA- MXZ-4A71VA- E5 E6 E7 E5 E6 E7 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Remarks RC0J60Including heat sink and RT64 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 Indoor unit connecting Power supply DEFROST, DISCHARGE OUTDOOR HEAT EXCHANGER 20A 600μH T3.15AL250V T6.3AL250V T2AL250V No. RoHS 16-9. ACCESSORY Parts No. Parts Name Q'ty/unit Symbol MXZ-4A71VAin Wiring MXZ-3A54VAE6 E7 E5 E6 E7 Diagram E5 1 2 15 G E12 817 704 DRAIN SOCKET 16 G E12 444 705 DRAIN CAP 183 1 2 1 2 1 2 1 2 1 2 Remarks RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E1 16-10. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 25 24 23 22 21 19 18 20 2 14 15 17 16 1 2 5 13 6 11 7 8 9 10 3 4 184 12 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E1 16-10. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 RoHS Part numbers that are circled are not shown in the illustration. G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Parts No. M21 M21 M21 M21 T92 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 L2V L2V L2V L2V 505 L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V 232 027 010 245 801 505 401 654 401 653 401 652 401 651 290 644 247 667 668 248 959 642 646 402 651 297 523 630 249 937 936 938 656 Parts Name FRONT PANEL HANDLE ASSEMBLY GRILLE SERVICE PANEL COMPRESSOR COMPRESSOR RUBBER SET EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL BASE ASSEMBLY UNION PIPE COVER BALL VALVE (LIQUID) 3/8 BALL VALVE (GAS) 5/8 REAR PANEL POWER RECEIVER 4-WAY VALVE HIGH PRESSURE SWITCH EXPANSION VALVE LEV COIL TOP PANEL REAR GUARD OUTDOOR HEAT EXCHANGER SIDE PANEL CAPILLARY TUBE CAPILLARY TUBE CAPILLARY TUBE OIL SEPARATOR Symbol in Wiring Diagram MC LEV D LEV C LEV B LEV A HPS LEV E 185 Q'ty/unit MXZ-4A80VA1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 Remarks E1 TNB220FMCH 3RUBBERS SET D room D room C room C room B room B room A room A room 12.7, 9.52, 6.35 SET 9.52 15.88 4.8 MPa (48.9 kg/cm2) E 4.0 4.0 2.5 2.4 400 2.8 90 0.6 1000 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E1 16-11. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS 12 11 10 9 8 7 1 16-12. ACCESSORY 2 3 4 5 16 186 6 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E1 16-11. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS No. RoHS Part numbers that are circled are not shown in the illustration. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 G G G G G G G G G G G G G G G Parts No. M21 M21 T2W T2W M21 T2W T2W T2W M21 T2W M21 M21 T2W T2W T2W L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V L2V 501 301 440 451 337 424 376 377 307 398 308 309 381 382 313 Parts Name Symbol in Wiring Diagram PROPELLER MF OUTDOOR FAN MOTOR POWER BOARD ELECTRONIC CONTROL P.C. BOARD REACTOR L NOISE FILTER P.C. BOARD TERMINAL BLOCK TB2~5 TERMINAL BLOCK TB1 GAS PIPE TEMPERATURE THERMISTOR RT6A,B,C,D R.V. COIL 21S4 THERMISTOR SET RT61,62,68 AMBIENT TEMPERATURE THERMISTOR RT65 FUSE F801 FUSE F911 FUSE&VARISTOR SET F64,NR64 Q'ty/unit MXZ-4A80VA- E1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 Remarks PM8H60Including heat sink and RT64 20A 600μH Indoor unit connecting Power supply DEFROST, DISCHARGE, OUTDOOR HEAT EXCHANGER T3.15AL250V T1AL250V T2AL250V No. RoHS 16-12. ACCESSORY Parts No. Parts Name Symbol in Wiring Diagram 16 G T2W L2V 704 DRAIN SOCKET ASSEMBLY Q'ty/unit MXZ-4A80VA1 187 E1 Remarks DRAIN SOCKET DRAIN CAP 2 1 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E2 MXZ-5A100VA - E1 16-13. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 22 21 23 20 24 19 17 18 15 16 14 2 1 2 5 6 13 7 8 9 10 11 12 3 4 188 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E2 MXZ-5A100VA - E1 16-13. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 RoHS Part numbers that are circled are not shown in the illustration. G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Parts No. M21 M21 M21 M21 T92 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 M21 T2W M21 M21 M21 M21 M21 M21 0A2 0A2 L2V 0A2 505 L2V L2V 0A2 L2V L2V L2V L2V L2V L2V L2V L2V 0A2 0A2 0A2 0A2 0A2 L2V L2V L2V 0A2 0A2 L2V 0A2 0A3 0A2 L2V L2V 0A2 0A2 L2V L2V 232 027 010 245 801 505 401 651 401 654 401 653 401 652 401 651 290 644 668 667 248 642 646 402 402 652 297 523 630 630 249 959 937 936 938 656 Parts Name FRONT PANEL HANDLE ASSEMBLY GRILLE SERVICE PANEL COMPRESSOR COMPRESSOR RUBBER SET EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL EXPANSION VALVE LEV COIL BASE ASSEMBLY UNION STOP VALVE (LIQUID) 3/8 STOP VALVE (GAS) 5/8 REAR PANEL 4-WAY VALVE HIGH PRESSURE SWITCH EXPANSION VALVE EXPANSION VALVE LEV COIL TOP PANEL REAR GUARD OUTDOOR HEAT EXCHANGER OUTDOOR HEAT EXCHANGER SIDE PANEL POWER RECEIVER CAPILLARY TUBE CAPILLARY TUBE CAPILLARY TUBE OIL SEPARATOR Q'ty/unit Symbol in Wiring MXZ-4A80VA- E2 MXZ-5A100VADiagram MC 1 2 1 1 1 3 LEV E LEV D LEV C LEV B LEV A HPS LEV F 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 189 1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 5 1 1 Remarks E1 TNB220FMCH 3RUBBERS SET E room E room D room D room C room C room B room B room A room A room 12.7, 9.52, 6.35 SET 9.52 15.88 4.8 MPa (48.9 kg/cm2) F F 3.0 4.0 2.5 2.0 300 2.8 100 0.6 1000 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E2 MXZ-5A100VA - E1 16-14. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS 11 10 9 8 7 1 16-15. ACCESSORY 2 3 15 190 4 5 6 RoHS PARTS LIST (RoHS compliant) MXZ-4A80VA - E2 MXZ-5A100VA - E1 16-14. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS No. RoHS Part numbers that are circled are not shown in the illustration. Parts No. 1 G M21 L2V 2 G M21 L2V 3 G M21 0A1 G T2W 0A3 4 G T2W 0A2 5 G M21 L2V 6 G M21 0A0 7 G T2W 0A2 8 G T2W L2V 9 G T2W L2V 10 G M21 L2V 11 G M21 0A2 12 G T2W L2V 13 G M21 0A2 14 G M21 T0A 501 301 440 451 451 337 424 376 377 398 308 309 381 313 313 Parts Name Q'ty/unit Symbol in Wiring MXZ-4A80VA- E2 MXZ-5A100VADiagram PROPELLER MF OUTDOOR FAN MOTOR POWER BOARD ELECTRONIC CONTROL P.C. BOARD ELECTRONIC CONTROL P.C. BOARD REACTOR L NOISE FILTER P.C. BOARD TERMINAL BLOCK TB2~6 TERMINAL BLOCK TB1 R.V. COIL 21S4 THERMISTOR SET RT61,62,68 AMBIENT TEMPERATURE THERMISTOR RT65 FUSE F801,931 FUSE&VARISTOR SET F64,NR64 FUSE F65 1 1 1 1 1 1 4 1 1 1 1 1 1 1 E1 1 1 1 Remarks PM8H60Including heat sink and RT64 1 1 1 5 1 1 1 1 1 1 1 20A 600μH Indoor unit connecting Power supply DEFROST, DISCHARGE, OUTDOOR HEAT EXCHANGER T3.15AL250V T2AL250V T6.3AL250V No. RoHS 16-15. ACCESSORY Parts No. Parts Name Q'ty/unit Symbol in Wiring MXZ-4A80VA- E2 MXZ-5A100VADiagram 15 G T2W L2V 704 DRAIN SOCKET ASSEMBLY 1 191 1 E1 Remarks DRAIN SOCKET DRAIN CAP 2 1 17 OPTIONAL PARTS 17-1. DIFFERENT-DIAMETER PIPE Unit: mm (inch) MXZ-3A54 MXZ-4A71 MXZ-4A80 MXZ-5A100 Model name MAC-A454JP For differentdiameter pipes MAC-A455JP MAC-A456JP PAC-493PI PAC-SG76RJ-E Connected pipes diameter 9.52 — (3/8) 12.7 — (1/2) 12.7 — (1/2) 6.35 — (1/4) 9.52 — (3/8) 12.7 (1/2) 9.52 (3/8) 15.88 (5/8) 9.52 (3/8) 15.88 (5/8) Length A Length B 9.52 (3/8) 12.7 (1/2) 12.7 (1/2) 6.35 (1/4) 9.52 (3/8) 12.7 (1/2) 9.52 (3/8) 15.88 (5/8) 9.52 (3/8) 15.88 (5/8) Length C A 69 65 B C 66.5 60.5 101.5 17-2. OUTLET GUIDE Changes air discharge direction. 48 15.7 Z-Z 450.8 42.6 10 x 48 (=480) 51H-855 79 MAC-855SG 327 506-889 537.2 MAC-889SG Z 103.1 MXZ-4A80 MXZ-5A100 Model name Model code 7 524 7 13.7 52. 5° Punched hole 4- 6 538 Applied unit MXZ-2A30 MXZ-2A40 MXZ-2A52 MXZ-3A54 MXZ-4A71 Z 71.6 MAC-889SG 109.4 51.8 29.2 150 5- 6 Punched hole 5- 6 Punched hole 29.2 386 534 6.4 832 760.8 416 6.4 610.4 534 386 MAC-855SG HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Copyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD Distributed in Dec. 2008. No.OB377 REVISED EDITION-H 6 Distributed in Sep. 2008. No.OB377 REVISED EDITION-G 6 Distributed in Dec. 2007. No.OB377 REVISED EDITION-F 8 Distributed in Aug. 2007. No.OB377 REVISED EDITION-E 8 Distributed in May 2007. No.OB377 REVISED EDITION-D 8 Distributed in Feb. 2007. No.OB377 REVISED EDITION-C 8 Distributed in Oct. 2006. No.OB377 REVISED EDITION-B 8 Distributed in Dec. 2005. No.OB377 REVISED EDITION-A 8 Distributed in Feb. 2005. No.OB377 8 Made in Japan New publication, effective Dec. 2008 Specifications subject to change without notice.