Transcript
Utilities & Configuration Digital PRIORIS XL Server ROM Based Setup This option is often used by educational facilities that have public access to their servers. Disabling this option prevents unauthorized personnel from changing any server’s configuration parameters. Parallel Port and Serial Ports The server logically assigns LPTx and COMx names to: ♦ ♦ Parallel ports in the address order 378h and 278h. Serial ports in the address order 3F8h, 2F8h, 3E8h, and 2E8h. This occurs during each boot process. For example, When disabling the serial port that is assigned to 3F8h as COM1, during the next boot cycle the server reassigns the name COM1 to the next enabled serial port in the sequence. Server Boot Management The server comes from the factory with options Boot From Diskette A and Boot From Hard C enabled. This means that each time you turn on or reset the server it attempts to first boot from diskette A and then from hard disk drive C. When changing the server’s boot sequence, be aware of the following: P R I O R I S Boot From Diskette A Boot From Hard Disk C Comments Disabled Disabled Enabled Disabled Disabled Enabled (1) Allowed only if booting from a network server. Server will only boot from diskette A(1). Server will only boot from hard disk drive C. When a second diskette drive installed, you can choose which one to boot from using the "Exchange Diskette Drives" setup option. X L 30 MCS Logistics Engineering - Nijmegen