Download Bryant 376CAV Instruction manual
Transcript
FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING NOTE 2 W FIVE WIRE THREE-WIRE HEATING-ONLY C R G Y THERMOSTAT TERMINALS FIELD-SUPPLIED DISCONNECT 208/230- OR 460-V THREE PHASE BLOWER DOOR SWITCH BLK BLK WHT WHT GND W C O N T R O L GND 115-V FIELDSUPPLIED DISCONNECT AUXILIARY J-BOX R 208/230-V SINGLE PHASE G C GND NOTE 1 CONDENSING UNIT Y 24-V TERMINAL BLOCK FURNACE TWO WIRE NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation. 2. Some thermostats require a "C" terminal connection as shown. 3. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. A98521 Fig. 10—Heating and Cooling Application Wiring Diagram BLOWER OFF DELAY ADJUSTMENT SWITCH G 24-V THERMOSTAT TERMINALS R Y TEST/TWIN W Com 24V HUM HUMIDIFIER TERMINAL (24-VAC 0.5 AMP MAX) LED OPERATION & DIAGNOSTIC LIGHT HARNESS CONNECTOR SEC-1 24-V TRANSFORMER SEC-2 3-AMP FUSE SPARE-1 COOL HEAT BLOWER SPEED SELECTION TERMINALS SPARE-2 EAC-1 (BLACK) EAC-ELECTRONIC AIR CLEANER TERMINALS (115-VAC 1 AMP MAX) 115-VAC (L1) POWER SUPPLY HOT SURFACE IGNITOR CONNECTOR EAC-2 (WHITE) 115-VAC (L2) NEUTRAL CONNECTION INDUCER MOTOR CONNECTOR A00292 Fig. 11—Furnace Control —7—