Maintenance Schedule
Application Group 3B
4
5
Item
Task
W3
LT coolant pump
Check relief bore for oil and water discharge and
obstructions ( Page 6 49).
W3
Engine coolant cooler
Check cooler elements for external contamination (see
manufacturer s documentation).
W3
Charge-air coolant cooler
Check cooler elements for external contamination (see
manufacturer s documentation).
W3
Coupling
Check condition (see manufacturer s documentation).
W3
Battery
Check (see manufacturer s information).
W4
HP pump
Check relief bore for oil and fuel discharge and obstructions
( Page 6 14).
W4
Air filter
Replace (
W4
Starter
Check condition (
W4
Battery-charging generator drive
Check belt condition (
W4
Battery-charging generator drive
Check and adjust belt tension (
W4
Battery-charging generator
Check condition (
W4
Engine / generator mounts
W4
Engine / generator mounts
W4
Engine wiring
W4
ECU
W4
ECU
en
t.r
u
W
Page 6 30).
Page 6 32).
Page 6 50).
Page 6 50).
er
Page 6 52).
Check tightness of securing screws (
Page 6 53).
Check condition of resilient mounts (
Page 6 53).
en
Check (
Page 6 55).
Check (visual inspection) (
Page 6 56).
w
w
w
.g
Clean (
Page 6 57).
M015403/00E
02-09