Download Agilent Technologies 6834B User`s guide
Transcript
Language Dictionary - 3 Source Subsystem (Frequency) This subsystem programs the output frequency of the ac source. Subsystem Syntax [SOURce:] FREQuency [:CW | :IMMediate] <n> :MODE <mode> :SLEW [:IMMediate] <n> | INFinity :MODE <mode> :TRIGgered <n> | INFinity :TRIGgered <n> Sets the frequency Sets frequency mode (FIX | STEP | PULS | LIST) Sets the frequency slew rate Sets frequency slew mode (FIX | STEP | PULS | LIST) Sets the triggered frequency slew rate Sets the triggered frequency FREQuency This command sets the frequency of the output waveform. Command Syntax Parameters Unit *RST Value Examples Query Syntax Returned Parameters Related Commands [SOURce:]FREQuency[:CW | :IMMediate] <NRf+> refer to Specifications Table in User’s Guide HZ (hertz) 60 FREQ 50 [SOURce:]FREQuency[:CW | :IMMediate]? <NR3> FREQ:MODE FREQ:SLEW FREQuency:MODE This command determines how the output frequency is controlled during a triggered output transient. The choices are: FIXed STEP PULSe LIST The output frequency is unaffected by a triggered output transient. The output frequency is programmed to the value set by FREQuency:TRIGgered when a triggered transient occurs. The output frequency is changed to the value set by FREQuency:TRIGgered for a duration determined by the pulse commands. The output frequency is controlled by the frequency list when a triggered transient occurs. Command Syntax Parameters *RST Value Examples Query Syntax Returned Parameters Related Commands [SOURce:]FREQuency:MODE <mode> FIXed | STEP | PULSe | LIST FIXed FREQ:MODE FIX [SOURce:]FREQuency:MODE? <CRD> FREQ FREQ:TRIG 65