Download Agilent Technologies 6633A User`s guide
Transcript
Verification and Calibration - B Check the Language Setting The verification procedures can only be performed with the dc source set to the SCPI programming language. Action Normal Result 1. Turn on the dc source, access the Address menu and scroll to the LANG: command. LANG: SCPI or LANG:COMP 2. If the language is set to COMPatibility, change it to SCPI and press Enter. If the language is already set to SCPI, just continue with the verification procedure. LANG: SCPI Voltage Programming and Measurement Accuracy This test verifies the voltage programming, GPIB measurement, and front panel meter functions. Values read back over the GPIB should be the same as those displayed on the front panel. Measure the dc output voltage at the output terminals. Make sure the sense switch is set to remote and the sense terminals are directly jumpered to the output terminals. Action Normal Result 1. Turn off the dc source and connect a DMM to the output terminals. 2. Turn on the dc source with no load on the output. Set the output voltage to 0.01 V and the output current to 3 A. Press Output On/Off to enable the output. Output voltage near 0 V. Output current near 0 A. 3. Record the voltage reading on the DMM (Vout) and the voltage reading on the front panel display. Readings within low voltage limits (see table B-2). 4. Set the output voltage to 15 V. 5. Record the voltage reading on the DMM (Vout) and the voltage reading on the front panel display. Output voltage near 15 V. Readings within high voltage limits (see table B-2). Current Programming and Measurement Accuracy This test verifies the current programming and measurement. Connect the appropriate current monitor (see table B-1) as shown in figure B-1A. High Range Current Programming and Measurement Action Normal Result 1. Turn off the dc source and connect the DMM and current monitor as shown in figure B-1A. Then turn on the dc source. 2. Agilent Model 66311B Only Access the Input menu, and set the current sense detector to DC. 3. Set the output voltage to 5 V and the current to 0 A. Press Output On/Off to enable the output. Output current near 0 A. 4. Divide the voltage drop across the current monitor by its resistance to convert the value to amperes. Record this value (Iout). Reading within low current limits (see table B-2). 5. Set the output current 3 A. 6. Divide the voltage drop across the current monitor by its resistance to convert the value to amperes. Record this value (Iout). Also record the current reading on the front panel display. CURR:DET DC Readings within high current limits (see table B-2). 139