POLYCLIM 21A+Timer+Fog – User’s Manual
3.2.3. Reading screens
Reading Menu  Ventilation (next :
or
to change screen)
Screen 1/4 :
for double side ventilation
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
+xx.x°C Left | Right
Status> xxxxxx|xxxxxx
Setp. > +xx.x°|+xx.x
Mini > xxx% | xxx%
Pos. > xxx% | xxx%
Maxi > xxx% | xxx%
for single side ventilation
or
Air
Temp° >+xx.x°C
Status
> xxxxxx
Setpoint
> +xx.x°
Minimum Open.> xxx%
Position
> xxx%
Maximum Open.> xxx%
Measured ambient temperature and priority side in reverse video
Ventilation status : Manual, Repositioning, Immobile, Opening or Closing
Calculated setpoint for each side
Calculated minimum opening for each side
Calculated actual position for each side
Calculated maximum opening for each side
Screen 2/4 :
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
Weather
D/N Period
Strong Wind
Light Wind
Rain
Dehumidification
>
>
>
>
>
D.
xx
xx
xx
xx
Daytime period (day/night or active period number)
Strong wind detected ? ( : no / : yes)
Light wind detected ? ( : no / : yes)
Rain detected ? ( : no / : yes)
Dehumidification in process ? ( : no / : yes)
Screen 3/4 :
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
Influences Weather
Wind
xxxKm/h>+x.x°C
Ext.T° +xx.x°C>+x.x°C
Sun. xxxxW/m²>+x.x°C
Princ. Setp. > xx.x°C
Regul. Range > xx.x°C
Wind influence on principal setpoint
External temperature influence on principal setpoint
Sunniness influence on principal setpoint
Calculated principal setpoint
Calculated regulation range
Version 3.x – February 2010 – Page 32