Download RBH700, RBH800 - Muziekhuis Da Capo

Transcript
Laney
RBW100
RBW200
RBW300
RBH700
RBH800
RBG400
RBG500
Laney
1
INTRODUCTION
Congratulations on your decision to purchase a Laney amplifier.
Laney products are designed with ease of operation as a primary objective, however to ensure you derive the best
from your new amplifier, it is important you take time to read this user manual and to familiarise yourself with the
control functions and facilities available
BEFORE
SWITCHING ON
After unpacking your amplifier check that it is factory fitted with a three pin 'grounded' (or earthed) plug. Before
plugging into the power supply ensure you are connecting to a grounded earth outlet.
If you should wish to change the factory fitted plug yourself, ensure that the wiring convention applicable to the
country where the amplifier is to be used is strictly conformed to. As an example in the United Kingdom the cable
colour code for connections are as follows.
EARTH OR GROUND - GREEN/YELLOW
NEUTRAL - BLUE
LIVE - BROWN
This manual has been written for easy access of information. The front and rear panels of each unit are
graphically illustrated, with each control and feature numbered. For a description of the function of each control
feature, simply check the number with the explanations adjacent to each panel.
Your Laney RICHTER bass amplifier has undergone a thorough two stage, pre-delivery inspection, involving
actual play testing, as well as burn in.
When you first recieve your Laney RICHTER bass amp, follow these simple procedures:
(i) Ensure that the amplifier is set at the correct voltage for the country it is to be used in.
(ii) Connect your instrument with a high quality shielded instrument cable. Use of cheap cables will compromise
the sound of your instrument and your amplifier.
If there is a problem with your Laney RICHTER bass amplifier
DON'T
DO
PHONE YOUR DEALER!
Care of your Laney amplifier will prolong it's life.....and
Laney
2
RBW100 front
PARAMID
PASSIVE/
ACTIVE ACTIVE
4 5 6
3
7
2
2
8
1
0
INPUT
3
4
BASS
COMP
1K
-0+
4 5 6
1
FREQUENCY
5
GAIN
8
1
0
4
5
5
1
7
2
3
4
4
5
3
2
33
4
100
5
1
2 2
3
4
5
POWER
1 -0+ 1
2
2
3
9
10
GAIN
500
1 -0+ 1
9
10
0
VOLUME
TREBLE
D.I.
PHONES
RBW100
RBW100 rear
MADE IN THE UNITED KINGDOM BY BLT INDUSTRIES LTD.
WARNING THIS EQUIPMENT MUST BE EARTHED.
ATTENTION REMPLACER LE FUSIBLE
MAXIMUM POWER CONSUMPTION
140 WATTS ~ 50 - 60 Hz
PAR LE MEME ET LE CALIBRE.
CAUTION
TO REDUCE THE
~115V
~230V
SUPPLY VOLTAGE
& FUSE RATING
T2A
T1A
CAUTION TO REDUCE THE RISK OF ATTENTION DEBRANCHER A LA PRISE
ELECRIC SHOCK DO NOT REMOVE SECTEUR AVAVT D'OUVRIR.
COVERS. NO USER SERVICABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL
SERIAL No:
WARNING TO REDUCE THE RISK
OF FIRE OR ELECTRIC SHOCK DO
NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE.
RISK OF
FIRE HAZARD REPLACE FUSE WITH
SAME TYPE AND RATING ONLY.
RETURN
SEND
EFFECTS LOOP
CE
RBW200 front
POWER
PARAMID
ACTIVE
PASSIVE/
ACTIVE
4
5
8
1
0
INPUT
GAIN
7 2
2
COMP
9
3
4
ENHANCE
5
BASS
4
5
1K
FREQUENCY
4
5
GAIN
5
8
7
8
2
1
9
0
10
LIMIT
PRESENCE DEFEAT VOLUME
TREBLE
1
6
3
7
1
0
5
4
6
32
4
5
5
4
2 3
33
4
100
1-0+ 1
2 2
3
4
5
10
1-0+ 1
2
2
83
1
0
9
10
500
1-0+ 1
6
3
7
2
5
4
6
3
9
0
10
HORN
D.I.
RBW200
RBW200 rear
WARNING THIS EQUIPMENT MUST BE EARTHED.
SUPPLY VOLTAGE
& FUSE RATING
MADE IN THE UNITED KINGDOM BY BLT INDUSTRIES LTD.
EXTERNAL
SPEAKER
MINIMUM 8 OHM
MAXIMUM POWER CONSUMPTION
300 WATTS ~ 50 - 60 Hz
~115V
T5A
~230V
T2A
TO REDUCE THE RISK
OF ELECRIC SHOCK DO NOT REMOVE
COVERS. NO USER SERVICABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL
ATTENTION DEBRANCHER A LA PRISE
PAR LE MEME ET LE CALIBRE.
CAUTION
CE
CAUTION
ATTENTION REMPLACER LE FUSIBLE
TO REDUCE THE RISK OF
FIRE HAZARD REPLACE FUSE WITH
SAME TYPE AND RATING ONLY.
SERIAL No:
EFFECTS LOOP
WARNING TO REDUCE THE RISK
RETURN
OF FIRE OR ELECTRIC SHOCK DO
SEND
NOT EXPOSE THIS APPLIANCE TO
SECTEUR AVAVT D'OUVRIR.
RAIN OR MOISTURE.
TUNER
RBW300/RBH700/RBH800 front
LO PARAMID
PASSIVE/
ACTIVE
ACTIVE
4
5
6
3
2
1
0
INPUT
4
8
7
9
10
ENHANCE
500
1
2
3
4
5
BASS
1K
FREQUENCY
1-0+
3
5
GAIN
4K
4
5
FREQUENCY
3
4
5
GAIN
5
LIMIT
TREBLE DEFEAT
1
6
7
2
4
5
5
3
2
33
4
400
4
1
2 2
3
4
5
1-0+
1
2
2
4
100
1K5
1
3
4
5
POWER
HI PARAMID
1-0+
2
2
83
1
0
COMP
1-0+
6
2
9
10
GAIN
5
3
7
8
1
0
9
0
10
VOLUME
HORN
D.I.
RBW300
RBW300 rear
WARNING THIS EQUIPMENT MUST BE EARTHED.
MAXIMUM POWER CONSUMPTION
300 WATTS ~ 50 - 60 Hz
SUPPLY VOLTAGE
& FUSE RATING
~115V
T5A
~230V
T2A
EXTERNAL
SPEAKER
MINIMUM 8 OHM
MADE IN THE UNITED KINGDOM BY BLT INDUSTRIES LTD.
ATTENTION REMPLACER LE FUSIBLE
PAR LE MEME ET LE CALIBRE.
CAUTION
TO REDUCE THE RISK OF
FIRE HAZARD REPLACE FUSE WITH
SAME TYPE AND RATING ONLY.
CE
CAUTION
TO REDUCE THE RISK
OF ELECRIC SHOCK DO NOT REMOVE
COVERS. NO USER SERVICABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL
ATTENTION DEBRANCHER A LA PRISE
SECTEUR AVAVT D'OUVRIR.
SERIAL No:
WARNING TO REDUCE THE RISK
OF FIRE OR ELECTRIC SHOCK DO
EFFECTS LOOP
RETURN
SEND
NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE.
TUNER
Laney
3
RBW100 front
PARAMID
PASSIVE/
ACTIVE ACTIVE
4 5 6
3
7
2
2
8
1
0
500
1 -0+ 1
3
9
10
3
4
5
1K
INPUT
GAIN
COMP
BASS
FREQUENCY
1
2
3
4
5
-0+
4 5 6
1
2
33
4
100
1
2 2
3
4
5
POWER
1 -0+ 1
2
2
4
5
5
GAIN
6
3
4
4
5
5
3
1
7
2
8
1
0
9
10
0
TREBLE
VOLUME
D.I.
7
8
9
PHONES
RBW100
10
RBW100 rear
WARNING THIS EQUIPMENT MUST BE EARTHED.
MADE IN THE UNITED KINGDOM BY BLT INDUSTRIES LTD.
ATTENTION REMPLACER LE FUSIBLE
MAXIMUM POWER CONSUMPTION
140 WATTS ~ 50 - 60 Hz
SUPPLY VOLTAGE
& FUSE RATING
~115V
~230V
PAR LE MEME ET LE CALIBRE.
CAUTION
TO REDUCE THE
T2A
T1A
RISK OF
FIRE HAZARD REPLACE FUSE WITH
SAME TYPE AND RATING ONLY.
WARNING TO REDUCE THE RISK
OF FIRE OR ELECTRIC SHOCK DO
NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE.
CAUTION TO REDUCE THE RISK OF ATTENTION DEBRANCHER A LA PRISE
ELECRIC SHOCK DO NOT REMOVE SECTEUR AVAVT D'OUVRIR.
COVERS. NO USER SERVICABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL
SERIAL No:
RETURN
SEND
EFFECTS LOOP
CE
11
12 13
1.Inputs:
Active and Passive/Active Inputs: ACTIVE and PASSIVE/ACTIVE inputs are provided for
connection of bass guitars. Active basses should be connected via the ACTIVE socket. Non
active basses should be connected using the passive input. Active basses may also be placed in
the PASSIVE input if pre-amp overloading is desired.
2.Gain:
Gain: This control is used to set the level of gain present in the pre-amp. The higher the level of
gain, the more the signal will clip producing distortion. The GAIN control should be used in
conjunction with the VOLUME control (8) to produce the desired signal characteristics.
3.Compressor:
Compressor: Engages and disengages the on-board COMPRESSOR. This compresses the
input-signal giving a punchier sound.
4.Bass:
Bass: Controls the low-frequency response of the pre-amplifier.
5.Paramid frq:
Paramid-Frequency: Selects the MID-frequencies to be cut or boosted in conjunction with the
PARAMID GAIN control (6). To access LO mid-frequencies turn the FREQUENCY control
anticlockwise, to access HI mid frequencies turn the FREQUENCY control clockwise.
6.Paramid Gain:
Paramid-Gain: Sets the level of boost or cut applied to the frequency set by control 5. For
frequency-boost turn the control clockwise. For frequency-cut, turn the control anti-clockwise.
7.Treble:
8.Volume:
9.D.I:
Treble: Controls the high-frequency response of the pre-amplifier.
Volume: Sets the overall listening level of the amplifier.
Direct Inject: XLR socket for direct-injection of the amplifier signal to a mixing-desk or additional
power-amplifier. The XLR socket provides a low-impedance output-signal.
10.Phones:
Phones: Headphone output for silent practicing.
11.FX loop:
FX Loop: Send and return sockets are provided for connecting external effects-units.
12.Tuner out:
13.Horn switch:
Tuner out: Socket for connecting external tuner.
Horn switch: Switches the on-board horn either on or off.
Laney
4
RBW200 front
PARAMID
PASSIVE/
ACTIVE
ACTIVE
5
4
3
8
1
0
GAIN
INPUT
1
COMP
3
4
9
ENHANCE
3
BASS
WARNING THIS EQUIPMENT MUST BE EARTHED.
5
6
T5A
~230V
T2A
4
5
5
15
8
1
0
LIMIT
7
7
2
TREBLE PRESENCE DEFEAT
MADE IN THE UNITED KINGDOM BY BLT INDUSTRIES LTD.
9
0
10
VOLUME
16
HORN
D.I.
RBW200
8
CE
CAUTION
TO REDUCE THE RISK
OF ELECRIC SHOCK DO NOT REMOVE
COVERS. NO USER SERVICABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL
ATTENTION DEBRANCHER A LA PRISE
ATTENTION REMPLACER LE FUSIBLE
PAR LE MEME ET LE CALIBRE.
CAUTION
8
9
10
1
6
3
7
1
0
5
4
6
32
4
5
GAIN
EXTERNAL
SPEAKER
MINIMUM 8 OHM
~115V
4
5
1K
FREQUENCY
4
14
MAXIMUM POWER CONSUMPTION
300 WATTS ~ 50 - 60 Hz
SUPPLY VOLTAGE
& FUSE RATING
100
5
4
2 3
33
4
5
1-0+ 1
2 2
3
4
5
10
POWER
1-0+ 1
2
2
83
1
0
2
RBW200/RBW300 rear
7 2
2
9
10
500
1-0+ 1
6
3
7
2
5
4
6
TO REDUCE THE RISK OF
FIRE HAZARD REPLACE FUSE WITH
SAME TYPE AND RATING ONLY.
SERIAL No:
EFFECTS LOOP
WARNING TO REDUCE THE RISK
RETURN
OF FIRE OR ELECTRIC SHOCK DO
SEND
NOT EXPOSE THIS APPLIANCE TO
SECTEUR AVAVT D'OUVRIR.
RAIN OR MOISTURE.
TUNER
11
17
12
14.Enhance: Enhance: The ENHANCE control provides an increased definition at the low-end of the
frequency spectrum giving you a tighter, punchier sound. The ENHANCE control does this
by providing a dip in the frequency-response of the amplifier at approximately 200hz. This
dip eliminates some of the secondary-harmonics of the important low-frequencies around
40-80 Hz producing a thicker sound. Turning the control through to its maximum has the
effect of boosting both the low and high-frequency content of the signal whilst not effecting
the mids.
15.Presence: Presence: Controls the high-frequency signal-content of the pre-amplifier. The PRESENCE
control is set at 3K.
16.Limiter: Limiter Defeat: Allows the on-board LIMITER to be defeated if desired. With the switch in
the out position the LIMITER is engaged. The LIMITER is automatically triggered at highoutput levels and is designed to prevent power-amp distortion at high-output levels. The
LIMITER monitors both power-amp clipping and load so it automatically registers the
cabinet-impedance and sets itself accordingly.
17.Spkr. socket: External speaker socket: This socket should be used to connect an extension-cabinet.
The impedance of the extension-cabinet must not be less the 8 Ohms. Connecting
cabinets that have a lower impedance than 8 Ohms will result in the amplifier overheating;
continual use in this manner may cause permanent damage. Connecting a cabinet with an
impedance of greater than 8 Ohms will cause no damage to the amplifier but will result in a
reduced output.
RBW300/RBH700/RBH800 front
LO PARAMID
PASSIVE/
ACTIVE
ACTIVE
4
5
6
3
2
8
1
0
INPUT
1
4
5
7
2
9
10
500
1
2
1-0+
3
4
5
3
4
100
1K
GAIN
COMP
ENHANCE
BASS
FREQUENCY
2
3
14
4
18
1-0+
5
GAIN
19
4K
4
5
5
FREQUENCY
GAIN
20
21
3
4
LIMIT
TREBLE DEFEAT
7
7
8
1
0
5
16
1
6
2
4
5
5
3
2
33
4
400
4
1
2 2
3
4
5
1-0+
1
2
2
3
4
5
POWER
HI PARAMID
1K5
1
2
2
83
1
0
9
10
1-0+
6
3
7
9
0
10
VOLUME
HORN
D.I.
8
13
9
RBW300
Laney
5
23.Line out: Line Out: Socket for providing a line-level-signal-source for connecting to an additional
external power-amplifier.
24. Pre shapes: Hi and Lo Preshapes: There are two factory-determined EQ settings which can be used as
building-blocks in conjunction with the onboard graphic-EQ (25) to achieve individual tone. The
HI button adds boost to the high-end of the frequency spectrum whilst the LO button adds
additional low-end boost to the signal.
25. Graphic EQ: Graphic EQ: The 6-band onboard GRAPHIC-EQ allows extensive tonal-shaping to be
achieved. With the sliders along the centre-line the GRAPHIC-EQ will exert a flat signalresponse; it is at this point that individual frequency-bands can be cut or boosted. Moving the
slider beneath the centre-line will incur a frequency-cut; conversely, pushing the slider above
the centre-line facilitates frequency-boost. As a general rule, avoid extreme settings of the
sliders: try to set the GRAPHIC with as little cut or boost as possible.
26. Full, Bright & Full, Bright & Horns: The FULL button engages a speaker-control function that produces a
Horns EQ: pronounced, tighter bottom-end. The BRIGHT button adds an increased attack and sparkle to
the upper frequencies present in the amplifier. The HORNS switch engages or disengages the
onboard horns.
Laney
6
Intended to alert the user to the presence of uninstalled "dangerous voltage" within the product's enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in
the literature accompanying the product.
Caution: Risk of electrical shock - DO NOT OPEN!
Caution: To reduce the risk of electrical shock, do not remove cover. No user servicable parts inside. Refer servicing to
qualified service personnel.
WARNING: To prevernt electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this
appliance, read the operating guide for further warnings.
This apparatus must be earthed. The wires in these mains are coloured in accordance with the following code.
Green & Yellow Earth
Blue Neutral
Brown Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows: - The wire which is coloured GREEN & YELLOW must be connected to
the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or Green and yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
If a 13 amp (BS1363) plug is used a 13-amp fuse must be fitted, or if any other type of plug is used a 15 amps fuse must be
fitted either in the plug or adapter or at the distribution board.
EMC warning
It is inherent in the design of a loudspeaker and in the design of guitar pickups that they should emit or be affected by electro
magnetic fields. Loudspeaker enclosures should not be used less than two meters away from equipment, which is likely to
be affected by electro magnetic interference.
Likewise, guitar fitted with electro magnetic pickups should not be used less than two meters away from any source of
emissions such as loudspeakers. Emissions from loudspeakers are dependent on the frequency characteristics of the drive
unit. Levels were measured direct from the driver of 30 dBuV. These levels are reduced to a safe level at a distance of 1,27
meters from the drivers.
BLT Industries Ltd.,
Newlyn Road,
Cradley Heath,
West Midlands.
B64 6BE.
Http://www.laney.co.uk
Tel: (0044) (0)1384 633821
Fax: (0044) (0)1384 639186
In the interest of continued product development BLT Industries Ltd. Reserves the
right to amend product specification wihtout prior notification.