Download DWL-80GnPro Instruction Manual finalv5

Transcript
Digi-Pas
Digi-Pas Digital Level
TECHNICAL SPECIFICATION
®
®
A Ventura Group of Companies
Dimension
Weight
Operating Temp
Storage Temp
Battery
ON/OFF: Turn on/off device
USER MANUAL
: 107 x 55 x 18
: 100 Grams
: 0° ~ +50°(Celsius)
: -10° ~ +60°(Celsius)
: 2 x CR2032 (3V)
CLEANING
DIGITAL LEVEL
* Do not submerge device in water while cleaning . Wiping
or cleaning on device surface is sufficient
Applications
Vial
Alt.Zero :
- Press to activate
alternate zero mode
- Press & Hold to turn off/on
buzzer sound
ISO 14001:2004
Cert No: TWO4/00450EM
Magnet
CAL: Activate Calibration Mode
MODE SELECT :
- Press to change display unit
: 0.05°, %, mm/M, In/ft
- Press & Hold to freeze Display value
ISO 9001:2008
Cert No: QSP00050
Product of Singapore
CAUTION
CALIBRATION INSTRUCTIONS
Digi-Pas device is calibrated in the factory for
maximum accuracy. User can re-calibrate when
necessary.
1.(a). Push Once on the CAL button, “CAL 1” blinks.
Refer to www.digipas.com for video
demonstration on how to calibrate the device.
BATTERY COMPARTMENT
Glue
For first time usage,
remove the plastic
strip to connect
the battery.
STEP 1
(b). Place DWL80G/Pro on a flat & clean surface
(e.g. Table)
2.(a). Press MODE, display counts down from
10,9,8.......1, “CAL 2” blinks.
(b). Place DWL80G/Pro reverse horizontal (180°) Press
MODE, display counts down, “CAL 3” blinks.
E.g Table Surface
Push Once “ CAL”
STEP 2
a.
CAL
(c). Place DWL80G/Pro vertically (-90°). Press MODE
button, display counts down, “CAL 4” blinks.
Press Mode button Once
(d).Place DWL80G/Pro reverse vertically (+90°). Press
MODE button, display counts down.
CALIBRATION DONE.
Remove Screw to
remove battery from
the compartment
CALIBRATION PICTURE
180°
WARRANTY
The Digi-Pas ® Digital level is warranted to the original
purchaser to be free from defects in workmanship and material.
JSB Tech will, at its option, repair or replace any detective part
which may malfunction under normal and proper use within a
period of 1 (one) year from the date of shipment. The foregoing
warranty shall not apply to defects resulting from misuse, abuse
or transfer by the Buyer, Buyer-supplied software or interfacing,
unauthorized modification or operation outside of environmental
specifications for the product. JSB Tech does not warrant that the
operation of the instrument software, or firmware, will be
uninterrupted or error free. The exclusive remedy under any
and all warrants and guarantees, expressed herein, and we shall
not be liable for damages from loss or delay of equipments uses,
consequential, or incidental damage. No other warranty is
expressed or implied. JSB Tech specifically disclaims the
implied warranties of merchantability and fitness for a
particular purpose.
b.
NOTE: Ensure Digi-Pas device is kept still during
calibration.
d.
c.
90°
CAL
Manufactured by
JSB TECH Pte Ltd
Email: [email protected]
Press Mode button Once
Press Mode button Once
www.digipas.com
JIM-2-00082-99