Transcript
Digi-Pas Digi-Pas Digital Level TECHNICAL SPECIFICATION ® ® A Ventura Group of Companies Dimension Weight Operating Temp Storage Temp Battery ON/OFF: Turn on/off device USER MANUAL : 107 x 55 x 18 : 100 Grams : 0° ~ +50°(Celsius) : -10° ~ +60°(Celsius) : 2 x CR2032 (3V) CLEANING DIGITAL LEVEL * Do not submerge device in water while cleaning . Wiping or cleaning on device surface is sufficient Applications Vial Alt.Zero : - Press to activate alternate zero mode - Press & Hold to turn off/on buzzer sound ISO 14001:2004 Cert No: TWO4/00450EM Magnet CAL: Activate Calibration Mode MODE SELECT : - Press to change display unit : 0.05°, %, mm/M, In/ft - Press & Hold to freeze Display value ISO 9001:2008 Cert No: QSP00050 Product of Singapore CAUTION CALIBRATION INSTRUCTIONS Digi-Pas device is calibrated in the factory for maximum accuracy. User can re-calibrate when necessary. 1.(a). Push Once on the CAL button, “CAL 1” blinks. Refer to www.digipas.com for video demonstration on how to calibrate the device. BATTERY COMPARTMENT Glue For first time usage, remove the plastic strip to connect the battery. STEP 1 (b). Place DWL80G/Pro on a flat & clean surface (e.g. Table) 2.(a). Press MODE, display counts down from 10,9,8.......1, “CAL 2” blinks. (b). Place DWL80G/Pro reverse horizontal (180°) Press MODE, display counts down, “CAL 3” blinks. E.g Table Surface Push Once “ CAL” STEP 2 a. CAL (c). Place DWL80G/Pro vertically (-90°). Press MODE button, display counts down, “CAL 4” blinks. Press Mode button Once (d).Place DWL80G/Pro reverse vertically (+90°). Press MODE button, display counts down. CALIBRATION DONE. Remove Screw to remove battery from the compartment CALIBRATION PICTURE 180° WARRANTY The Digi-Pas ® Digital level is warranted to the original purchaser to be free from defects in workmanship and material. JSB Tech will, at its option, repair or replace any detective part which may malfunction under normal and proper use within a period of 1 (one) year from the date of shipment. The foregoing warranty shall not apply to defects resulting from misuse, abuse or transfer by the Buyer, Buyer-supplied software or interfacing, unauthorized modification or operation outside of environmental specifications for the product. JSB Tech does not warrant that the operation of the instrument software, or firmware, will be uninterrupted or error free. The exclusive remedy under any and all warrants and guarantees, expressed herein, and we shall not be liable for damages from loss or delay of equipments uses, consequential, or incidental damage. No other warranty is expressed or implied. JSB Tech specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. b. NOTE: Ensure Digi-Pas device is kept still during calibration. d. c. 90° CAL Manufactured by JSB TECH Pte Ltd Email: [email protected] Press Mode button Once Press Mode button Once www.digipas.com JIM-2-00082-99